COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
Connect.
Bevel
CNM 9506
BRG MANDREL
ESPECIAL
1 7/8"
---
1"
---
---
---
---
OK
2 7/8 REG
3 3/4"
3 5/8"
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
Qc
E N D
Lsc BBCD BBCL
3 1/16" 11/16"
---
---
LX
LBT
---
3 15/16"
Tong
Cond.
Space
Total
Length
Gauss
5 3/4"
2' 8 5/8"
0.0
OK
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
BRG MANDREL CNM 9506 PRESENTA DESPRENDIMIENTO DE CROMO LEVE EN DIAMETRO EXTERIOR
Customer
COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
Connect.
Bevel
CNM
9502/3682A0
BRG MANDREL
ESPECIAL
1 7/8"
---
1"
---
---
---
---
OK
2 7/8 REG
3 23/32"
3 19/32"
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
Qc
E N D
Lsc BBCD BBCL
3 1/16" 11/16"
---
---
LX
LBT
---
3 15/16"
Tong
Cond.
Space
Total
Length
Gauss
5 3/4"
2' 8 5/8"
0.0
OK
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
Customer
COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
Connect.
Bevel
CNM 9503
3628A02
BRG MANDREL
ESPECIAL
1 7/8"
---
1"
---
---
---
---
OK
2 7/8 REG
3 3/4"
3 5/8"
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
Qc
E N D
Lsc BBCD BBCL
3 1/16" 11/16"
---
---
LX
LBT
---
3 15/16"
Tong
Cond.
Space
Total
Length
Gauss
5 3/4"
2' 8 5/8"
0.0
OK
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
Customer
COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
Connect.
Bevel
CNM 9505
BRG MANDREL
ESPECIAL
1 7/8"
---
1"
---
---
---
---
OK
2 7/8 REG
3 3/4"
3 5/8"
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
Qc
E N D
Lsc BBCD BBCL
3 1/16" 11/16"
---
---
LX
LBT
---
3 15/16"
Tong
Cond.
Space
Total
Length
Gauss
5 3/4"
2' 8 5/8"
0.0
OK
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
BRG MANDREL CNM 9505 PRESENTA DESPRENDIMIENTO DE CROMO LEVE EN DIAMETRO EXTERIOR
Customer
COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
5635A06CT
BEARING ASSEMBLY
ADAPTER
---
---
---
---
---
---
---
---
OK
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
Connect.
ESPECIAL
2 13/32"
E N D
Bevel
Qc
---
---
---
---
LX
---
Tong
Cond.
Space
---
2 11/16"
7 5/8"
---
---
---
---
---
---
---
OK
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
Gauss
0.0
OK
--ESPECIAL
Total
Length
Customer
0.0
COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
Connect.
Bevel
Qc
3627A07
PISTON HOUSING
ESPECIAL
3 3/4"
---
2 1/2"
---
---
---
---
OK
ESPECIAL
3 3/4"
---
---
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
E N D
Lsc BBCD BBCL
---
---
---
LX
LBT
---
---
Tong
Cond.
Space
---
OK
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
Customer
Total
Length
Gauss
1' 2 7/8"
0.0
COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
Connect.
Bevel
5119A01
TOP SUB
ESPECIAL
3 3/4"
---
1 29/32"
---
---
---
---
OK
2 3/8 IF
3 3/4"
3 29/64"
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
Qc
E N D
Lsc BBCD BBCL
2 15/16" 11/16"
---
---
LX
LBT
---
3 7/8"
Tong
Cond.
Space
---
MAQ
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
TOP SUB 5119A01 PRESENTA HILOS CORROIDOS Y SELLO CORROIDO EN CONEXIN BOX. REPARAR
Customer
Total
Length
Gauss
1' 6"
0.0
COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
Connect.
Bevel
Qc
5119B01CT
TOP SUB
ESPECIAL
3 3/4"
---
1 29/32"
---
---
---
---
OK
2 3/8 IF
3 23/32"
3 33/64"
2 15/16"
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
E N D
Tong
Cond.
Space
LX
LBT
5/8"
---
3 11/16"
---
---
---
OK
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
Customer
Total
Length
Gauss
1' 6"
0.0
COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
Connect.
Bevel
5119B04
TOP SUB
ESPECIAL
3 3/4"
---
1 29/32"
---
---
---
---
OK
2 3/8 IF
3 23/32"
3 33/64"
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
Qc
E N D
Lsc BBCD BBCL
2 15/16" 11/16"
---
---
Tong
Cond.
Space
LX
LBT
---
3 23/32"
---
MAQ
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
TOP SUB 5119A04 PRESENTA HILOS CORROIDOS EN CONEXIN BOX. REPARAR
Customer
Total
Length
Gauss
1' 6"
0.0
COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
Connect.
Bevel
Qc
5119B02
TOP SUB
ESPECIAL
3 3/4"
---
1 29/32"
---
---
---
---
OK
2 3/8 IF
3 3/4"
3 33/64"
2 15/16"
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
E N D
Tong
Cond.
Space
LX
LBT
5/8"
---
3 23/32"
---
---
---
MAQ
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
TOP SUB 5119A02 PRESENTA SELLO E HILOS CORROIDOS EN CONEXIN BOX. REPARAR
Customer
Total
Length
Gauss
1' 6"
0.0
COMPANY
ORDERED BY
Ogar Tineo.
LOCATION
WELL / RIG
DATE
INSPECTOR
INSPECCTION METHOD
VISUAL THREAD
LIQUID PENETRANT
MAGNETIC PARTICLE:
DIMENSIONAL
TIME PENETRANT
PARTICLE CONCENTRATION
ULTRASONIC
TIME DEVELOPER
E-mail: inspeccion.negritos@spctalaraperu.com
P I N
E N D
B O X
Serie
Description
Connect.
Bevel
RGW
DRG
Lp
Tong
Space
Cond.
Connect.
Bevel
Qc
3579A05
END CAP
ESPECIAL
3 3/4"
---
2 1/2"
---
---
---
---
OK
---
---
---
---
* ACCEPTANCE CRITERIA:
WET
0.25ml/100ml
2200 W/cm2
5
ASTM Designation E 709 - 08: "Standard Guide for Magnetic Particle Examination"
Standard DS-1: "Drill Stem Inspection", Volume 3, Fourth Edition, TH Hill Asociates, INC.
API SPEC 7 - 1: "Specification for Rotary Drill Stem Elements"
API RP 7G - 2: "Recommended Practice fot Inspection and Classification of Used Drill Stem Elements"
REFERENCES:
inspeccion.elalto@spctalaraperu.com
UV INTENSITY
DRY
E N D
Lsc BBCD BBCL
---
---
---
LX
LBT
---
---
Tong
Cond.
Space
---
---
Los criterios de aceptacin y rechazo para Inspeccin Dimensional se eligen de acuerdo a la Tabla 3.8, Standard DS-1. Pag. 193 - +
Los criterios de aceptacin y rechazo para Inspeccin Visual se eligen de acuerdo al Standard DS-1. Seccin 3.11.4, Pag. 42 - +
Remarks:
LA HERRAMIENTA INSPECCIONADA NO PRESENTA DEFECTOS RECONOCIDOS POR EL METODO MPI.
Customer
Total
Length
Gauss
8 5/16"
0.0