Sunteți pe pagina 1din 46

FlexiPacket Hub & Radio Commissioning

FlexiPacket Hub & Radio Commissioning

Contents
1
1.1
1.2
1.3
1.4

First Installation Procedure


Scope
PC requirements
Commissioning with A2200: Before Starting
Commissioning with A1200: Before Starting

FT4289DEN02GLA0
2010 Nokia Siemens Networks

3
4
4
5
37

FlexiPacket Hub & Radio Commissioning

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

First Installation Procedure

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

1.1

Scope

This chapter gives the procedures to install for the first time (starting from a scratch
configuration) the FlexiPacket Microwave (made up of one FlexiPacket Hub
2200/1200 and one or more FlexiPacket Radios, connected to the FlexiPacket Hub).

Fig. 1

1.2

PC requirements

Computer running a Windows XP operating system with:


Java (JRE) version 1.6 or higher installed on the computer
Active serial port (COM port)

1 x Ethernet cable (copper)


Serial the RJ-45 console cable (provided with the FlexiPacket Hub)
USB-serial adapter

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

1.3

Commissioning with A2200: Before Starting

We'll do the commissioning taking as example the 1+1 link reported in Fig. 2.
In the example, the A2200 HUB is used.

Local Station
1

A-2200
2

NNI
NNI

ODU
Stanby

IP= 10.86.43.241
255.255.255.240

255.255.255.240
GTW= 10.86.43.254

IP= 10.86.43.243
255.255.255.240

Coupler (Bal)

IP= 10.86.43.242

ODU
Main

GTW= 10.86.43.254

Tx 14516500 Khz
Rx 14936500 Khz
Radio Port=UP
BW=56Mhx
ATPC=Disable
ACM= Enable

GTW= 10.86.43.254

IP=10.86.43.247
255.255.255.240

LCT

GTW=10.86.43.254

Remote Station
1

A-2200
2
IP= 10.86.43.244
255.255.255.240

NNI
NNI

ODU
Stanby

255.255.255.240
GTW= 10.86.43.254

IP= 10.86.43.246
255.255.255.240
GTW= 10.86.43.254

Coupler (Bal)

IP= 10.86.43.245

ODU
Main

Tx 14936500 Khz
Rx 14516500 Khz
Radio Port=UP
BW=56Mhx
ATPC=Disable
ACM= Enable

GTW= 10.86.43.254

Fig. 2

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

1.3.1

Install the LCT 3.2

Follow the instructions reported in Chapter in order to install the LCT 3.2.
The Installation procedure will install also the Filezilla FTP Server in your Computer

Fig. 3 LCT Installation Window

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

1.3.2

FlexiPacket Hub reset to the Default

Before starting the first installation procedure, reset the HUB to the default
configuration.
Connect the serial cable to your computer's serial (COM) port at one end, and to the
FlexiPacket Hub CONSOLE port at the other.

Console Cable

USB to Serial Adaptor cable


(if needed)

Fig. 4

Define the following values for the serial connection:

Bits per second = 9600


Data bits = 8 (default)
Parity = None (default)
Stop bits = 1 (default)
Flow control = None

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

Fig. 5 HyperTerminal Configuration for the Console connection

Login to the FlexiPacket HUB typing:

login: root
password: root

root

Fig. 6 A2200 login

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

In order to reset the hub to the default configuration, type the command shown in Fig.
7 and type y when required:

Fig. 7 Command to reset the A2200 to the Default Configuration

Wait till the login prompt appears:

Fig. 8 Login prompt

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

1.3.3

Starting the A2200 HUB First Time Installer

1) Log out from the A1200 CLI and Close the Hyper-terminal connection. Connect
the Ethernet cable to your computer Ethernet port at one end, and to the FlexiPacket
Hub MANAGEMENT port at the other as reported in Fig. 9

Console Cable

Eth Cable

USB to Serial Adaptor cable (if needed)

Fig. 9

2) Assign to your computer the IP address 192.168.255.101 with Net Mask


255.255.255.0.
3) Verify that the installed FTP server is currently running on your computer.
4) Take note about the ODUs Frequency Range

10

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

5) Start the Installer from the LCT Menu

Fig. 10

A window opens displaying the requirements for running the application.

Point 3 is a Mistake: FTP


must be running

Fig. 11

6) Click OK to continue the installation.

FT4289DEN02GLA0
2010 Nokia Siemens Networks

11

FlexiPacket Hub & Radio Commissioning

The procedure (starting from the 4.5.0013) takes about 20 minutes

Fig. 12

7) Towards the end of the installation, the application will pause and you will be
prompted to reconnect the Ethernet cable to a different port on the FlexiPacket Hub:

Fig. 13

12

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

Console Cable

Default LCT Assigned Port


i.e. Eth Cable on:

Eth Cable

Slot 1 / Port 8

USB to Serial Adaptor cable


(if needed)

Fig. 14

8) Click OK to continue the installation.


9) When the installation is over, close the application and disconnect the serial cable.

Fig. 15

10) Now the FlexiPacket Hub has the default IP address 192.168.255.100 as
loopback IP

FT4289DEN02GLA0
2010 Nokia Siemens Networks

13

FlexiPacket Hub & Radio Commissioning

Default LCT Assigned Port


i.e. Eth Cable on:

Eth Cable

Slot 1 / Port 8

Fig. 16

11) Make a ping to 192.168.255.100 to check the correct connection

Fig. 17

14

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

1.3.4

Start the FlexiPacket Commissioning Tool

1) Start the FlexiPacket Commissioning Tool

Fig. 18 FlexiPacket Commissioning Tool

2) Set the Host IP address (PC IP) and the default IP HUB. Select First Installation,
insert the Passwords and click OK (Fig. 19).

private

sysmanager

Fig. 19 Login Dialog

FT4289DEN02GLA0
2010 Nokia Siemens Networks

15

FlexiPacket Hub & Radio Commissioning

3) The Hub View of the Commissioning Tool opens.

Fig. 20

16

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

4) Click Modify and enter the Hub IP address.

LOCAL STATION

Fig. 21

REMOTE STATION

Fig. 22

FT4289DEN02GLA0
2010 Nokia Siemens Networks

17

FlexiPacket Hub & Radio Commissioning

5) Wait until a Warning message will appear. Click OK

Fig. 23

6) Change the PC IP Address in order to put it in the same HUB Subnetwork.

Fig. 24

18

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

7) Start again the Commissioning Tool application. Remove the check mark on the
First Installation box and insert the passwords.

LOCAL STATION

REMOTE STATION

Fig. 25

FT4289DEN02GLA0
2010 Nokia Siemens Networks

19

FlexiPacket Hub & Radio Commissioning

8) the following windows appears

LOCAL STATION

Fig. 26

REMOTE STATION

Fig. 27

20

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

9) Click on Topology Management and then on Modify.

Fig. 28

FT4289DEN02GLA0
2010 Nokia Siemens Networks

21

FlexiPacket Hub & Radio Commissioning

10) Click on Add and insert all the FlexiPacket Radios to be connected to the Hub as
shown in the next screen.

LOCAL STATION

Fig. 29

REMOTE STATION

Fig. 30

22

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

I/F1 has only 7 ports (because port #8 is only used as management).


Select the Port Mode (UNI or NNI). Typically the ports are set as NNI. Only the first
port to access the transport network must be set as UNI.

Select the Tagged Mng (Yes or No), if the Mode is UNI.


Insert the IP Address with the relevant NetMask and the Default Gateway (if any).
The IP Address of the FlexiPacket Radios must be in the same Subnetwork of the
FlexiPacket Hub.

To remove a row put a check mark on the Remove column and click on Apply.
11) Click on apply
12) Click on Start. When the Committing procedure is complete (green indications
on) click on Stop and on Close".

Fig. 31

FT4289DEN02GLA0
2010 Nokia Siemens Networks

23

FlexiPacket Hub & Radio Commissioning

13) Close the Window

Fig. 32

14) Verify in the Topology Management the correct configuration then close the
window.

24

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

LOCAL STATION

Fig. 33

REMOTE STATION

Fig. 34

FT4289DEN02GLA0
2010 Nokia Siemens Networks

25

FlexiPacket Hub & Radio Commissioning

15) Select the LPG Commissioning menu and then Modify.

Fig. 35

26

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

16) Click on Add to create the Link Protection Group as shown in the next figure.

LOCAL STATION

Fig. 36

REMOTE STATION

Fig. 37

FT4289DEN02GLA0
2010 Nokia Siemens Networks

27

FlexiPacket Hub & Radio Commissioning

17) Insert the Commissioning Parameters

LOCAL STATION

Its possible to
configure the
synchronization later
via LCT

Fig. 38

REMOTE STATION
REMOTE STATION Its possible to
configure the
synchronization later
via LCT

Fig. 39

28

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

Insert the Commissioning Parameters

On LOCAL and
REMOTE STATION

Fig. 40

On LOCAL and
REMOTE STATION

Fig. 41

FT4289DEN02GLA0
2010 Nokia Siemens Networks

29

FlexiPacket Hub & Radio Commissioning

Insert the Commissioning Parameters

Frequency on the LOCAL STATION (its


enough putting the Frequency only in TX
or RX)

Fig. 42

Frequency on the REMOTE STATION (its


enough putting the Frequency only in TX
or RX)

Fig. 43

30

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

Insert the Commissioning Parameters

On LOCAL and
REMOTE STATION

Fig. 44

On LOCAL and
REMOTE STATION

Fig. 45

FT4289DEN02GLA0
2010 Nokia Siemens Networks

31

FlexiPacket Hub & Radio Commissioning

18) Click on Start to start the Committing procedure. In the example only one group
has been created.
When the Committing procedure is complete (green indication ON), click on Stop
and on Close.

Fig. 46

32

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

19) Close the Window

Fig. 47

FT4289DEN02GLA0
2010 Nokia Siemens Networks

33

FlexiPacket Hub & Radio Commissioning

20) Click on I/F Ports to verify the final configuration.

LOCAL STATION

Fig. 48

REMOTE STATION

Fig. 49

34

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

21) Click on Align Parameters menu to verify the parameters of the final
Configuration and to modify, if different. To modify click on Modify, change the
parameters and then click on Apply.

Fig. 50

22) LCT Connection after the Local Station and the Remote Station
Commissioning

Fig. 51

FT4289DEN02GLA0
2010 Nokia Siemens Networks

35

FlexiPacket Hub & Radio Commissioning

36

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

1.4

Commissioning with A1200: Before Starting

We'll do the commissioning taking as example the 1+1 link reported in Fig. 52.
In the example, the A1200 HUB is used.

Local Station
1

A-1200
2

NNI
NNI

ODU
Stanby

IP= 10.86.43.248
255.255.255.240

255.255.255.240
GTW= 10.86.43.254

IP= 10.86.43.250
255.255.255.240

Coupler (Bal)

IP= 10.86.43.249

ODU
Main

GTW= 10.86.43.254

Tx 14516500 Khz
Rx 14936500 Khz
Radio Port=UP
BW=56Mhx
ATPC=Disable
ACM= Enable

GTW= 10.86.43.254

IP=10.86.43.247
255.255.255.240

LCT

GTW=10.86.43.254

Remote Station
1

A-1200
2
IP= 10.86.43.251
255.255.255.240

NNI
NNI

ODU
Stanby

255.255.255.240
GTW= 10.86.43.254

IP= 10.86.43.253
255.255.255.240
GTW= 10.86.43.254

Coupler (Bal)

IP= 10.86.43.252

ODU
Main

Tx 14936500 Khz
Rx 14516500 Khz
Radio Port=UP
BW=56Mhx
ATPC=Disable
ACM= Enable

GTW= 10.86.43.254

Fig. 52

FT4289DEN02GLA0
2010 Nokia Siemens Networks

37

FlexiPacket Hub & Radio Commissioning

1.4.1

Install the LCT 3.2

Follow the instructions reported in Chapter in order to install the LCT 3.2.
The Installation procedure will install also the Filezilla FTP Server in your Computer.

1.4.2

FlexiPacket Hub reset to the Default

Connect the serial cable to your computer's serial (COM) port at one end, and to the
FlexiPacket Hub CONSOLE port at the other.

Console Cable

USB to Serial Adaptor cable


(if needed)

Fig. 53

Define the following values for the serial connection:

Bits per second = 115200


Data bits = 8 (default)
Parity = None (default)
Stop bits = 1 (default)
Flow control = None

38

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

Fig. 54 Fig. 5 HyperTerminal Configuration for the Console connection

Login to the FlexiPacket HUB typing:

login: root
password: root

root

Fig. 55

FT4289DEN02GLA0
2010 Nokia Siemens Networks

39

FlexiPacket Hub & Radio Commissioning

1.4.3

FlexiPacket Hub reset to the Default

In order to reset the hub to the default configuration, type the command shown in
figure and type y when required:

Fig. 56

Wait until the login prompt appears

Fig. 57

40

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

1.4.4

Start the A1200 first time Installer Application

Eth Cable

Console Cable

1) Log out from the A1200 CLI and Close the HyperTerminal connection. Connect
the Ethernet cable to your computer Ethernet port at one end, and to the FlexiPacket
Hub MANAGEMENT port at the other as reported in Fig. 58.

USB to Serial Adaptor cable


(if needed)

Fig. 58

2) Assign to your computer the IP address 192.168.255.101 with Net Mask


255.255.255.0.
3) Verify that the installed FTP server is currently running on your computer.
4) Take note about the ODUs Frequency Range

FT4289DEN02GLA0
2010 Nokia Siemens Networks

41

FlexiPacket Hub & Radio Commissioning

5) Start the Installer from the LCT Menu

Fig. 59

A window opens displaying the requirements for running the application.

Point 3 is a Mistake:
Installed FTP Server must
be running

Fig. 60

6) Click OK to continue the installation.

42

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

The procedure starts

Fig. 61

7) Towards the end of the installation, the application will pause and you will be
prompted to reconnect the Ethernet cable to a different port on the FlexiPacket Hub:

Fig. 62

FT4289DEN02GLA0
2010 Nokia Siemens Networks

43

FlexiPacket Hub & Radio Commissioning

Default LCT Assigned Port


i.e. Eth Cable on:

Eth Cable

Slot 0 / Port 8

Console Cable
USB to Serial Adaptor cable
(if needed)

8 Click OK to continue the installation.

Fig. 63

8) Click OK to continue the installation.


9) When the installation is over, close the application and disconnect the serial cable.

Fig. 64

10) Now the FlexiPacket Hub has the default IP address 192.168.255.100

44

FT4289DEN02GLA0
2010 Nokia Siemens Networks

FlexiPacket Hub & Radio Commissioning

Default LCT Assigned Port


i.e. Eth Cable on:

Eth Cable

Slot 0 / Port 8

Fig. 65

11) Make a ping to 192.168.255.100 to check the correct connection

Fig. 66

FT4289DEN02GLA0
2010 Nokia Siemens Networks

45

FlexiPacket Hub & Radio Commissioning

1.4.5

Start the FlexiPacket Commissioning Tool

1) Start the FlexiPacket Commissioning Tool and follow the same instructions
reported in chapter 1.3.4. considering that the two ODUs are connected to the
Interface 0 port 3 and port 4.
As example, consider the IP addresses reported in Fig. 52.

Fig. 67

46

FT4289DEN02GLA0
2010 Nokia Siemens Networks

S-ar putea să vă placă și