Sunteți pe pagina 1din 31

JEDEC

STANDARD

Requirements for Handling


Electrostatic-Discharge-Sensitive
(ESDS) Devices

JESD625B
(Revision of JESD625A, December 1999)

JANUARY 2012

JEDEC SOLID STATE TECHNOLOGY ASSOCIATION

NOTICE
JEDEC standards and publications contain material that has been prepared, reviewed, and
approved through the JEDEC Board of Directors level and subsequently reviewed and approved
by the JEDEC legal counsel.
JEDEC standards and publications are designed to serve the public interest through eliminating
misunderstandings between manufacturers and purchasers, facilitating interchangeability and
improvement of products, and assisting the purchaser in selecting and obtaining with minimum
delay the proper product for use by those other than JEDEC members, whether the standard is to
be used either domestically or internationally.
JEDEC standards and publications are adopted without regard to whether or not their adoption
may involve patents or articles, materials, or processes. By such action JEDEC does not assume
any liability to any patent owner, nor does it assume any obligation whatever to parties adopting
the JEDEC standards or publications.
The information included in JEDEC standards and publications represents a sound approach to
product specification and application, principally from the solid state device manufacturer
viewpoint. Within the JEDEC organization there are procedures whereby a JEDEC standard or
publication may be further processed and ultimately become an ANSI standard.
No claims to be in conformance with this standard may be made unless all requirements stated in
the standard are met.
Inquiries, comments, and suggestions relative to the content of this JEDEC standard or
publication should be addressed to JEDEC at the address below, or refer to www.jedec.org under
Standards and Documents for alternative contact information.
Published by
JEDEC Solid State Technology Association 2012
3103 North 10th Street
Suite 240 South
Arlington, VA 22201-2107
This document may be downloaded free of charge; however JEDEC retains the
copyright on this material. By downloading this file the individual agrees not to
charge for or resell the resulting material.
PRICE: Contact JEDEC

Printed in the U.S.A.


All rights reserved

PLEASE!

DONT VIOLATE
THE
LAW!

This document is copyrighted by JEDEC and may not be


reproduced without permission.
Organizations may obtain permission to reproduce a limited number of copies
through entering into a license agreement. For information, contact:

JEDEC Solid State Technology Association


3103 North 10th Street
Suite 240 South
Arlington, VA 22201-2107
or refer to www.jedec.org under Standards and Documents
for alternative contact information.

JEDEC Standard No. 625B

REQUIREMENTS FOR HANDLING ELECTROSTATIC-DISCHARGE-SENSITIVE (ESDS)


DEVICES

CONTENTS
Page
iii

Foreword
1 Scope
1.1 Applicable users
1.2 Applicable part types
1.3 Personnel Safety

1
1
1
1

2 Technical references

3 Terms and definitions

4 Inspection, measuring and test equipment


4.1 Recommended inspection, measuring and test equipment types

5
5

5 Facilities for ESD protected areas and workstations


5.1 Minimum requirements
5.2 Recommended compliance verification baseline
5.3 ESD item check records
5.4 Personnel grounding
5.5 Wrist strap and ESD protective footwear resistance path checks
5.5.1 Wrist strap resistance measurement path
5.5.2 Heel/toe strap and conductive shoe resistance measurement paths
5.5.3 Continuous wrist strap and workstation monitors
5.5.4 ESD protective smocks
5.6 Air ionization deployment
5.7 ESD signs and labels
5.7.1 Sign content and posting
5.7.2 ESD caution labels for packing and shipping
5.7.3 Package ESD caution label content
5.7.4 Commercial device package ESD caution label
5.7.5 Military device package ESD caution label

5
5
8
9
9
10
10
10
10
10
10
11
11
11
11
12
12

6 Grounding for protection of ESDS devices


6.1 ESD ground
6.1.1 Equipment and auxiliary ESD grounds
6.1.2 Equipment grounding receptacle and conductor
6.2 ESD protected workstation ESD ground
6.3 ESD protected worksurfaces
6.4 ESD protective flooring/mats
6.5 ESD ground connections
6.6 Ground wire mechanical considerations
6.7 Storage areas
6.8 Mobile ESD protected workstation

12
12
12
12
12
13
13
13
13
13
13

-i-

JEDEC Standard No. 625B

REQUIREMENTS FOR HANDLING ELECTROSTATIC-DISCHARGE-SENSITIVE (ESDS)


DEVICES

CONTENTS (continued)
Page
7 ESD-safe packaging requirements
7.1 ESD device protective packaging requirement
7.2 Packing and filler materials
7.3 Tubes, trays, magazines and carriers
7.4 Individual Finished device carrier materials
7.5 ESDS device shipping and receiving operations

14
14
14
14
14
14

8 Compliance verification
8.1 ESD coordinator
8.2 Frequency
8.3 Noncompliance
8.3.1 Noncompliant ESD protected areas and workstations
8.3.2 Mishandled ESDS device
8.3.3 Returning rejected ESDS devices to suppliers
8.4 Records

14
14
14
15
15
15
15
15

9 ESD handling training


9.1 Training program
9.2 Training records

15
15
15

10 Methods for minimizing static charging


10.1 Antistatic solution
10.2 Relative humidity control
10.3 Gloves/finger cots

16
16
16
16

11 Recommended ESD audit checklist

17

Annex A Informational/Reference Documents


Annex B Differences between JESD625B and JESD625-A

19
20

Figure 1 - ESD protected workstation


Figure 2 - Example of ESD protected package caution label

7
11

Table 1 - Minimum requirements for ESD protected areas , workstations, and tools
Table 2 - ESD protective item checks

-ii-

6
8

JEDEC Standard No. 625B

Foreword
This standard was prepared to standardize the requirements for a comprehensive Electrostatic Discharge
(ESD) control program for handling ESD-Sensitive (ESDS) devices. The requirements within this
standard were derived from existing industry standards, specifications, test methods, and input from
various industry reviews.
The intent of this document is for users to incorporate these minimal requirements into their ESD control
program to provide a consistent ESD protection level for their products.
This standard replaces JESD625-A and JEDEC Standard No. 42 (formerly JEDEC Publication 108-B,
Distributor Requirements for Handling Electrostatic-Discharge Sensitive (ESDS) Devices).

-iii-

-iv-

JEDEC Standard No. 625B


Page 1

REQUIREMENTS FOR HANDLING ELECTROSTATIC-DISCHARGE-SENSITIVE (ESDS)


DEVICES
(From JEDEC Board ballot JCB-11-66, formulated under the cognizance of JEDEC JC-14.1 Committee
on Reliability Test Methods for Packaged Devices and JEDEC JC-13.)

Scope

This standard establishes the minimum requirements for Electrostatic Discharge (ESD) control methods
and materials used to protect electronic devices that are susceptible to damage or degradation from
electrostatic discharge (ESD). The passage of a static charge through an electrostatic-discharge-sensitive
(ESDS) device can result in catastrophic failure or performance degradation of the part. Device
sensitivity to ESD is determined by test methods for Human-Body Model (ANSI/ESDA-JEDEC JS-001)
and Charged-Device Model (JESD22-C101). ESDS devices with HBM or CDM sensitivities of less than
200 volts may need additional protective measures beyond those specified in this standard.
1.1

Applicable users

a) Semiconductor Manufacturers - from wafer electrical probe through shipment of finished devices.
NOTE The requirements of this standard are not imposed prior to probe. Prior to probe, the manufacturer should
take appropriate ESD precautions to minimize damage to devices.

b) Semiconductor Processing/Testing Facilities - from receipt through shipment of finished devices


NOTE 1

ESDS Device Distributors and Users may use this standard or ANSI/ESD S20.20

NOTE 2 All ESDS devices shall be handled in accordance with this document until they are considered scrap.

1.2

Applicable device types

The device types for which these requirements are applicable include, but are not limited to, ESDsensitive discrete and integrated circuit semiconductors, multi-chip modules, optoelectronic devices, and
thin film passive devices.
1.3

Personnel safety

The procedures and equipment described in this document may expose personnel to hazardous electrical
conditions. Users of this document are responsible for selecting equipment that complies with applicable
laws, regulatory codes and both external and internal policy. Users are cautioned that this document
cannot replace or supersede any requirements for personnel safety. Ground fault circuit interrupters
(GFCI) and other safety protection should be considered wherever personnel might come into contact
with electrical sources. Electrical hazard reduction practices should be exercised and proper grounding
instructions for equipment shall be followed.

JEDEC Standard No. 625B


Page 2

Technical References

Unless otherwise specified, the following documents of the latest issue, revision or amendment, form a
part of this standard to the extent specified herein.
EIA-471

Symbol and Label for Electrostatic Sensitive Devices (JEDEC, JC-10)

ANSI/ESD-S541

Packaging Materials Standards for ESD sensitive Items

ANSI/ESD-STM3.1

Standard for Protection of Electrostatic Discharge Susceptible Items Ionization

ANSI/ESD-S4.1

Standard for Protection of Electrostatic Discharge Susceptible Items Worksurfaces - Resistive Characterization

ANSI/ESD-S6.1

Standard for Protection of Electrostatic Discharge Susceptible Items Grounding - Recommended Practice

ANSI/ESD-S7.1

Standard for Protection of Electrostatic Discharge Susceptible Items - Floor


Materials - Resistive Characterization of Materials

ANSI/ESD-S8.1

Standard for Protection of Electrostatic Discharge Susceptible Items


Symbols ESD Awareness

ANSI/ESDA/JEDEC JS-001Human Body Model (HBM) Electrostatic Discharge (ESD) Sensitivity


Testing Standard
JESD22-C101

Field Induced Charged Device Model Test Method for Electrostatic


Discharge Withstand Threshold for Microelectronic Devices

MIL-STD-129

Marking for Shipment and Storage

ANSI/ESD S20.20

Development of an Electrostatic Discharge Control Program for Protection


of Electrical and Electronic Parts, Assemblies and Equipment (Excluding
Electrically Initiated Explosive Devices

IEC 61340-5-1

Specification for the Protection of Electronic Devices from Electrostatic


Phenomena - Section 1: General Requirements.

ESD TR53-01-06

Compliance Verification of ESD Protective Equipment and Materials

ESD Handbooks and User Guides


ESD TR 20.20

Technical Report - Development of an Electrostatic Discharge Control


Program for Protection of Electrical and Electronic Parts, Assemblies and
Equipment (Excluding Electrically Initiated Explosive Devices - Handbook

IEC 61340-5-2

Specification for the Protection of Electronic Devices from Electrostatic


Phenomena - Section 2: User Guide.

JEDEC Standard No. 625B


Page 3

Terms and definitions

For the purpose of this standard the following definitions apply.


air ionizer: A source of charged air molecules (ions).

[3.1]

antistatic material: Refers to the property of material that inhibits triboelectric charging.

[3.2]

NOTE A material's antistatic property does not necessarily correlate with its resistivity or resistance. Unlike the
dissipative and conductive properties, antistatic is not defined by a measurable resistance range.

auxiliary ground: A separate supplemental ground conductor for use other than general equipment
grounding.
[3.3]
conductive material: A material that has a surface resistance less than 1x104 ohms or a volume
resistance less than 1x104 ohms.

[3.4]

NOTE A conductive material is not necessarily antistatic.

electrostatic charge: Electric charge at rest.

[3.5]

electrostatic discharge (ESD): The transfer of electrostatic charge between bodies or surfaces that are at
different electrostatic potentials.
[3.6]
ESDS device: electrostatic-discharge-sensitive device.

[3.7]

electrostatic field: Lines of force surrounding an electrically charged object.

[3.8]

electrostatic discharge shielding: A barrier or enclosure that limits the passage of an ESD current to the
stored or contained devices.
[3.9]
equipment ground: The entire low-impedance path (electrically equivalent to the equipment grounding
conductor) from a piece of electrical equipment to a hard-ground electrode (e.g., the third wire (typically
green) terminal of a receptacle).
[3.10]
ESD ground: The point, electrodes, bus bar, metal strips, or other system of conductors that form a path
from a statically charged person or object to ground. This ground is one of the following: a) AC Ground,
b) Auxiliary Ground, or c) Equipotential bonding system.
[3.11]
ESD- work area: A defined location with the necessary materials, tools, and equipment capable of
reducing static electricity to a level that minimizes damage to ESD susceptible items.
[3.12]
ESD-protected workstation: A work position with the necessary materials, tools and equipment capable
of controlling static electricity to a level that minimizes damage to ESD susceptible items.
[3.13]

JEDEC Standard No. 625B


Page 4

Terms and definitions (contd)

ESD-protective packaging: A packaging system that provides electrostatic discharge protection and
limits triboelectric charging to levels that do not result in device damage.
[3.14]
ESD-protective worksurface: A table top or other surface that minimizes damage to ESD-susceptible
items.
[3.15]
ground: (1) A conducting connection, whether intentional or accidental, between an electrical circuit or
equipment and the earth or some conducting body that serves in place of earth.
(2) The portion of an electrical circuit at zero potential with respect to the earth.
(3) A conducting body, such as the earth or the hull of a steel ship, used as a return path for electric
currents and as an arbitrary zero reference point.
[3.16]
groundable point: A designated connection, location, or assembly used on an ESD-protective material
or device that is intended to accommodate electrical connection from the device to ESD ground.
[3.17]
insulative material: A material having a surface or volume resistance equal to or greater than 1 x 1011
ohms.
[3.18]
static: A short form of electrostatic.

[3.19]

static dissipative material: A material having a surface resistance between 1 x 104 ohms and 1 x 1011
ohms or a volume resistance between 1 x 104 ohms and 1 x 1011 ohm centimeters.
[3.20]
NOTE A static-dissipative material is not necessarily antistatic.

static electricity: Electrical charge at rest.

[3.21]

NOTE The electrical charge is due to the transfer of electrons from one body to another.

surface resistance: The dc voltage divided by the current passing between two electrodes of specified
configuration that contact the same side of an insulative material or item.
[3.22]
NOTE Surface resistance is expressed in ohms.

triboelectric charging: The generation of electrostatic charges when two pieces of material in intimate
contact are separated (where at least one is an insulator).
[3.23]
NOTE Substantial generation of static electricity can be caused by contact and separation of two materials or by
rubbing two substances together.

unprotected ESDS device: An ESDS device that is not in an ESD protective package.

[3.24]

volume resistivity (v): The dc voltage per unit thickness, applied across two electrodes in contact with
a specimen, divided by the current per unit area passing through the system.
[3.25]
NOTE Volume resistivity is expressed in ohm centimeters.

JEDEC Standard No. 625B


Page 5

4
4.1

Inspection, measuring and test equipment


Recommended inspection, measuring and test equipment types

The recommended test equipment types and capabilities are listed below:
a) A Go/No-go tester, a meter, an in-line monitor, or equivalent resistance path measuring equipment
shall be capable of measuring the resistance of each connection path (e.g., wrist strap, heel strap or
ESD protective footwear) (see 5.5.1 and 5.5.2) within the limits specified in Table 2.
b) When continuous wrist strap or worksurface monitoring equipment is used, it shall alarm (audio
and/or visual) when the monitored item exceeds the limits specified in Table 2 and when there is a
broken or missing connection to ground.
c) When continuous e-field monitors are used at the ESD work station it shall alarm (audio and/or
visual) when e-field exceeds the limits specified in Table 2 is detected. ESD static voltage surveys
are not required where e-field monitor is used.
d) Electrostatic field meters shall be capable of verifying the presence of electrostatic fields in the work
environment.
1) Electrostatic field meters used in ionized air streams shall be constructed (e.g., chopperstabilized) to operate in that environment.
2) Items with measured electrical field greater than +/- 1000 volts/in are to be kept at least 30 cm
(12 in) from unprotected ESDS devices. This refers to measurements of made per the
manufacturers instructions, typically at one inch.
3) For insulators within 2.5 cm (1.0 inch) of a device the measured electric field shall be less than
+/- 250 volts/in.
e) Meters used to verify ESD ground continuity shall be capable of verifying resistance values less than
one ohm.
f) Meters used to measure resistance to ground and resistance point to point shall be capable of
verifying resistance values within the limits specified in Table 2.
g) Charged plate monitors shall be capable of measuring the charge neutralization properties of
ionization equipment within the limits specified in Table 2.

5
5.1

Facilities for ESD protected areas and workstations


Minimum requirements

The minimum requirements for ESD protected areas and workstations are listed in Table 1 and illustrated
in Figure 1.

JEDEC Standard No. 625B


Page 6

Facilities for ESD protected areas and workstations (contd)

5.1

Minimum requirements (contd)


Table 1 Minimum requirements for ESD protected areas and workstations

ITEM
1. ESD Protective
Worksurface

2. ESD Protective
Flooring or Floor
Mats
3. Personnel Grounding

MINIMUM REQUIREMENTS
The grounded static dissipative protective worksurface shall have a resistance to
ground of greater than or equal to 105 ohms and less than 109 ohms . Use of
conductive surfaces is not recommended. When used the conductive surface
may have a resistance to ground of less than 105 ohms.
Grounded flooring or floor mats are required when personnel or mobile ESD
protective workstations utilize floor grounding methods.
Each person handling unprotected ESDS devices shall be grounded using
EITHER:
a) Wrist straps that shall:
1) Provide a continuous electrical path from the user to ESD ground.
2) Have an integral resistance at the wrist band end of the grounding wire
that will limit current to less than 0.5 mA through that specific path to
ground at the highest power supply voltage that may be encountered.
3) Be worn by operators handling unprotected ESDS devices when seated.
b) ESD protective footwear (heel straps, toe straps or shoes) that shall:
1) Provide a continuous electrical path from the user directly to the ESD
protective flooring or floor mat.
2) Be worn on both feet.
3) Limit current through that specific path to ground appropriate for the
highest power supply voltage that may be encountered.
NOTE ESD protective footwear shall NOT be relied upon for grounding of seated
personnel.

4. Static Generating
Sources and
Charged Surfaces

5. ESD Protective
Smocks (optional)
6. ESD Protected Area
7. Grounding / Bonding
(See Figure 1)

a) Nonessential and personal items shall not be placed on ESD protective


worksurfaces. (Items which are essential are determined by the process
engineer and/or ESD coordinator)
b) For insulators within 2.5 cm (1.0 inch) of a device the measured electric
field shall be less than +/- 250 volts/in.
c) Operations, equipment or clothing generating electrostatic field greater than
1000 volts/inch within 30cm (12 inches) of unprotected ESDS devices
shall be neutralized or reduced to less than 1000 volts/inch.
When ESD protective smocks are required, they shall cover all personal
garments above the waist except at the neck area.
ESD protected areas shall be clearly identified at the entrance
Equipment Grounding Conductor (G1) per ANSI/ESD S6.1 shall have
impedance less than 1.0 ohm
Auxiliary Ground (G2) resistance to Equipment Grounding Conductor shall be
less than 25 ohms per ANSI/ESD S6.1

JEDEC Standard No. 625B


Page 7

Facilities for ESD protected areas and workstations (contd)

5.1

Minimum requirements (contd)

Auxiliary Ground

NOTE 1 G1 (equipment ground) or G2 (auxiliary ground) is acceptable for ESD ground. Where both
grounds are used, they shall be connected (bonded) together.(Resistance less than 25 ohms per ANSI/ESD
S6.1)
NOTE 2

R1 is mandatory for all wrist straps. Its value shall be within the limits specified in table 2, 1.a.

NOTE 3 R2 (for static dissipative worksurfaces) and R3 (for ESD protective floor mats) are optional but
not recommended. When R2 or R3 are used, the resistor values shall be as recommended by the ESD
protective equipment manufacturer. ESD protective flooring shall be connected directly to the ESD ground
without R3.
NOTE 4

See clause 6 of this standard for grounding details (Reference ANSI/ESD-S6.1).

Figure 1 Typical ESD protected workstation (Side View)

JEDEC Standard No. 625B


Page 8

5
5.2

Facilities for ESD protected areas and workstations (contd)


Recommended compliance verification baseline

Table 2 contains recommended initial checks. Frequencies of these checks may be changed based on data
collected for each item.
Table 2 ESD protective item checks
FREQUENCY
ITEMS
(see NOTES 1&2)
1. Required Prior To First a) Wrist straps (see Note 3).(when
Use of Each Day
continuous monitors are not in use.)

ACCEPTANCE
LIMITS
500 k to 10 M

REF.
PARA.
5.5/5.5.1

b) ESD protective footwear (see Note 4).

500 k to 109

5.5/5.5.2

c) Personnel ESD protective smock (e.g.,


buttoned smocks) on personnel
required to wear them.

Visual check

5.5.4

d) Wrist straps or ESD protective


Visual check
footwear on personnel required to wear
them.
2. Recommended Weekly a) ESD protected workstation. (e.g.,
ground connections)

5.4

Visual check

6.3

b) ESD protective floor mat (e.g.,


cleanliness and freedom from tears).

Visual check

6.4

c) ESD ground connections (e.g., wrist


straps, mat ground wires).

Visual check

6.5/6.6

3. Recommended
Monthly

ESD protected area and workstation static


voltage surveys of insulators and E-field
sources.

4.1d

4. Recommended
Quarterly

a) ESD protective static dissipative


worksurface to ESD ground resistance
(See Note 5).

within 2.5cm (1.0 inch) of a


device the measured electric field
shall be less than +/- 250 volts/in
and 1,000 volts/in within 30cm
(12 inches) of unprotected ESDS
devices
105 to <109

b) ESD conductive worksurface to ESD


ground resistance. (see NOTE 5)

<105 (with no series resistor)

3.4/6.3

c) ESD protective floor/mat to ESD


ground resistance using ANSI/ ESD
S7.1.

105 to <109 (see Note 7)

6.4

d) Wrist strap monitor check.

500 k to 10 M

5.5.3

e) ESD ground continuity from the


groundable point (e.g., mobile
equipment ground wires) using
EOS/ESD-S6.1.

<2.0

3.17/6.5/
6.6

3.20/6.3

JEDEC Standard No. 625B


Page 9

5
5.2

Facilities for ESD protected areas and workstations (contd)


Recommended compliance verification baseline (contd)
Table 2 ESD protective item checks (contd)

FREQUENCY
(see Notes 1&2)
5. Recommended
Semiannually

ITEMS
a) Ionizer balance using ANSI/ ESDSTM3.1. (see NOTE 6)

ACCEPTANCE LIMITS
Balance < 35 V

b) Ionizer charge decay performance using Charge decay performance per


ANSI/ESD-STM3.1. (See NOTE 8)
manufacturer's specification.
c) Wrist strap monitor check.
Test per manufacturer
recommendation

6. Recommended
Annually

ESD system compliance to the


requirements of this standard

REF.
PARA.
5.6c
5.6d
5.5.3

Using the ESD Audit Checklist 7.2


or equivalent.

NOTE 1 The ESD Item check frequencies should be established to ensure that the items remain compliant between checks.
NOTE 2 The ESD item checks shall be performed more frequently than listed when compliance is not continuously
maintained.
NOTE 3 Wrist straps in use shall be checked at least once a day when continuous wrist strap monitors are not used.
NOTE 4 ESD protective footwear is available in a wide range of resistance values. Those with mid-to-lower resistance values
provide shorter charge dissipation times.
NOTE 5 Use ANSI/ESD-S4.1 except make a single measurement using the limits specified in this standard at a high wear
point relative to the ground connection on the worksurface to the ESD ground (instead of several points to the groundable point).
All ESDS devices shall be removed from the worksurface while making these measurements.
NOTE 6 Use ANSI/ESD-STM3.1, except a single measurement point can be used for benchtop ionizing systems. Air velocity
measurements are not required.
NOTE 7 100K ohms is a suggested lower limit. However a lower value may be used if local safety requirements can still be
met.
NOTE 8 Use ANSI/ESD-STM3.1 except the number of measurement points and locations may be selected based on the
application.

5.3

ESD item check records

Records of the Table 2 ESD item checks shall be maintained for a minimum of one year except for
continuously monitored items
a) Compliant resistance and electrical potential measurements may be recorded either as variables (the
measured values) or attributes (pass/fail).
b) Noncompliant measurements must be recorded using variables (the measured values) when the
measuring equipment is capable of providing variables. Otherwise, the attribute (pass/fail) must be
recorded.
5.4

Personnel grounding

Personnel handling or within twelve (12) inches of unprotected ESDS devices shall be grounded per
Table 1.

JEDEC Standard No. 625B


Page 10

5
5.5

Facilities for ESD protected areas and workstations (contd)


Wrist strap and ESD protective footwear resistance path checks

While being worn, the resistance paths of wrist straps, heel/toe straps and conductive shoes shall be
independently checked to the Table 2 limits for minimum resistance (to provide current limiting
characteristics) and maximum resistance (to ensure that adequate body contact is maintained).
5.5.1

Wrist strap resistance measurement path

The wrist strap resistance path is measured from the user's hand, through the user's body, the body-tostrap contact, the integral resistor, the strap wire, to the strap ground connector.
5.5.2

Heel/toe straps and conductive shoes resistance measurement paths

Each heel/toe strap and conductive shoe resistance path shall be individually measured from the user's
hand, through the user's body, the body-to-strap/shoe contact, the strap/shoe to the conductive plate.
5.5.3

Continuous wrist strap and workstation monitors

When continuous wrist strap monitoring equipment is used, daily wrist strap checks and logs are not
required. Some monitors, usually capacitance or impedance types, may not meet the low end
requirements in Table 2, 1a. This does not increase risk of ESD damage but may be a safety concern.
Corrective actions resulting from monitor alarms shall be documented.
5.5.4

ESD protective smocks

ESD protective smocks may not be necessary for an effective ESD program. When they are required
such as for contamination control:
a) The ESD protective smocks shall be buttoned (except for the collar) whenever the wearer is at an
ESD protected workstation or in a designated ESD protected area.
b) The ESD protective smock manufacturer's cleaning instructions should be followed to gain maximum
effectiveness and utility from the smocks.
5.6

Air Ionization deployment

Air ionizers, when required, shall conform to the following:


a) Ionizers shall be positioned (e.g., distance and angle) so that the devices at the ESD-protected
workstations are within the intended specified coverage area.
b) There shall be an unrestricted, straight line air flow between the ionizers and the unprotected devices.
c) Ionizer balance (positive and negative ions) shall be verified per Table 2.
d) Ionizer charge decay performance shall be verified using the method described in EOS/ESD-STM3.1
per Table 2.

JEDEC Standard No. 625B


Page 11

5.7
5.7.1

ESD signs and labels


Indicating work area boundaries

ESD caution indicators shall be used to clearly indicate the ESD protected area boundaries and
workstations to all approaching personnel. These could be signs, identifying tape or marked physical
barriers. These should indicate by words and/or symbol that ESD HANDLING IS REQUIRED in the area
and/or at the workstation.
5.7.2

ESD caution labels for packing and shipping

Each ESD protective package shall have a contrasting ESD caution label. The caution label shall be
legible to normal vision. ESDA susceptibility or protective symbo1 in EIA471 or ESD S8.1 is
recommended. The ESD caution label shall be placed in a standard location to ensure that people will be
aware that ESDS devices are inside the packages. The ESD caution label on the package may be
provided by a preprinted marking on the package or its sealing tape.
5.7.3

Package ESD caution label content

The label shall clearly indicate by words and/or symbol that ESDS devices are inside the package and that
the package may not be opened except at a designated ESD protected area or workstation. An example of
an ESD protected package caution label is shown in Figure 2.

Figure 2 Example of ESD protected package caution label (ANSI/ESD 8.1-2007)

JEDEC Standard No. 625B


Page 12

5.7

ESD signs and labels (contd)

5.7.4

Commercial device package ESD caution label

For commercial devices, each ESD protective package shall have an ESD caution label placed in a
standard location to ensure that people will be aware that ESDS devices are inside the packages. The
ESD caution label on the package may be provided by a preprinted marking on the package or its sealing
tape.
5.7.5

Military device package ESD caution label

For military devices, the ESD caution label and its position shall conform to the requirements of
MIL-STD-129.

Grounding for protection of ESDS devices

6.1

ESD ground

The ESD ground shall be the equipment ground or auxiliary (earth) ground. Equipment ground is the
electrical ground (green) wire at receptacles that have been tested to and meet the requirements of
ANSI/ESD 6.1 or local equivalent.
A typical grounding system for an ESD protected workstation is illustrated in Figure 1.
6.1.1

Equipment and auxiliary ESD grounds

Equipment ground should be used instead of auxiliary ground. When an auxiliary ground is used it shall
be bonded to the service equipment ground with a maximum resistance of 25 ohms.
6.1.2

Equipment grounding receptacle and conductor

The equipment grounding receptacle and conductors shall be in accordance with ANSI/NFPA-70 and
ANSI/ESD S6.1 after being installed or modified and prior to being used.
NOTE ESD grounding conditions shall conform to the applicable building, electrical and safety codes and
standards.

6.2

ESD protected workstation ESD ground

Each ESD workstation shall be individually connected to the ESD ground. Daisy chaining is not
permitted. When more than one ESD worksurface is used at a workstation, each surface shall be
connected to a common point which is then connected to the ESD ground.
NOTE The Site Safety Engineer (or designated person) should perform a safety review of all new or modified
ESD Ground connections at the ESD Protected workstation prior to their initial use.

JEDEC Standard No. 625B


Page 13

Grounding for protection of ESDS devices (contd)

6.3

ESD protective worksurfaces

The grounded static dissipative protective worksurface shall have a resistance to ground of greater than or
equal to 105 ohms and less than 109 ohms. Use of conductive surfaces is not recommended. When used
the conductive surface may have a resistance to ground of less than 105 ohms.
NOTE The resistor R2 in Figure 1 should not be used in the connection to ground of conductive
worksurfaces.

6.4

ESD Protective flooring/mats

ESD protective flooring/mats are required when floor grounding devices (ESD protective footwear and/or
mobile ESD protected workstations) are utilized. When required ESD flooring/mats shall be grounded
and meet the requirement of Table 2 (4c).
6.5

ESD ground connections

Firm fitting connecting devices such as metallic crimps, snaps and banana plugs shall be connected to
designated ground points. Wire splices should be crimped or soldered. Use of alligator clips for ground
connections should be avoided.
6.6

Ground wire mechanical considerations

The wire used to connect the ESD ground to equipment ground should be of sufficient strength not to be
inadvertently broken or disconnected. The wire should be attached to physical structures to prevent
mechanical damage.
6.7

Storage areas

Shelving used as an ESD protected area or workstation shall meet all of the requirements for an ESD
protected area or workstation per clause 5 and Table 1 and Table 2.
When the storage shelving is not used as an ESD protected area or workstation, the ESDS devices shall be
in ESD protective packaging.
6.8

Mobile ESD protected workstation

When mobile equipment is used as an ESD protected workstation (e.g., cart, table), it shall be connected
to ESD ground and meet the requirements for an ESD protected workstation per 5.1, Table 1 (also see
3.13). When a floor grounding device is used to ground a mobile ESD protected workstation, an ESD
protective floor/mat is required.

JEDEC Standard No. 625B


Page 14

ESD Protective packaging requirements for ESDS devices

7.1

ESDS device protective packaging requirement

All ESDS devices shall be packed in ESD protective packaging (see 3.14) when not at an ESD protected
area or workstation.
7.2

Packing and filler materials

Packing and filler materials for ESDS devices shall be antistatic or static dissipative.
7.3

Tubes, trays, magazines and carriers

Tubes, trays, magazines and carriers shall provide mechanical protection for devices and minimize
triboelectric charging. Applying or removing static generating tapes and labels to antistatic tubes,
magazines and carriers shall not be done with ESDS devices inside. Topically-treated tubes, trays,
magazines and carriers lose their static protective properties with use. Re-use of topically treated tubes is
not recommended.
7.4

Individual finished device carrier materials.

Insulating (see 3.18) carrier materials may be used for individual finished devices for electrical testing
providing the handling methods minimize triboelectric charging of the carriers and surrounding materials.
7.5

ESDS device shipping and receiving operations

All ESDS devices must be shipped and received in ESD protective packaging, which must not be opened
except at an ESD protected area or workstation.

Compliance verification

8.1

ESD coordinator

Each site shall have a designated ESD coordinator. The coordinator is responsible for assuring that the
requirements of this standard are met.
8.2

Frequency

Verification frequency shall be defined for each control item or operation involving the processing,
handling or storage of ESDS devices, see Table 2.

JEDEC Standard No. 625B


Page 15

8.3

Non-compliance

When non-compliances to the requirements of this standard occur they shall be addressed according to
company quality management procedures.
8.3.1

Non-compliant ESD protected areas and workstations

When non-compliant ESD protected areas and/or workstations are found, no additional devices shall be
processed through that area and/or workstation until the non-compliance are corrected.
8.3.2

Mishandled ESDS devices

Company procedures shall define the disposition of ESDS devices or wafers that have NOT been
continuously handled, packaged and transported according to this standard.
8.3.3

Returning rejected ESDS devices to suppliers

Rejected (e.g., electrical, mechanical) ESDS devices being returned to suppliers shall be handled and
shipped in accordance with the requirements of this standard. When the supplier's original packing
materials and containers are non-compliant to this standard, the ESDS devices shall be rejected and
returned in the original materials and containers.
8.4

Records

Written records shall be kept of all audits and inspections, measuring and test equipment calibrations for
at least 2 years or as defined in the company quality management system. As a minimum, audit records
shall specify what was audited, the auditor's name, date of audit, audit results, corrective actions required
(if applicable), and evidence of verification of satisfactory completion of any required corrective actions.

ESD handling training

All personnel who handle ESDS devices shall receive ESD handling training prior to handling ESDS
devices. Refresh training shall be conducted at least every 24 months thereafter. Personnel entering ESD
protected areas shall be trained or accompanied by personnel who are trained.
9.1

Training program

The ESD handling training should include static fundamentals, a review of applicable parts of this
specification, and actual applications in the work area.
9.2

Training records

Training records shall be maintained for each individual. As a minimum, the records shall show dates of
training. Records shall be maintained for at least two (2) complete years or as prescribed by the company
quality management system

JEDEC Standard No. 625B


Page 16

10

Methods for minimizing static charging

Charge prevention/neutralization methods include, but are not limited to, antistatic solution treatments,
relative humidity control, air ionizers (5.6), ESD protective garments (5.5.4), and ESD gloves and finger
cots.
10.1

Antistatic solution

Antistatic chemicals (antistats) can be used to prevent static charge generation on static
generating/charging materials in the work or storage areas when a permanently low-charging or static
dissipative material is not available. During application of any antistatic chemical, the user should
consider the following:
a) The antistatic solutions should be chosen to avoid contamination of ESDS devices.
b) Antistatic spray or solutions should not be applied in any form to energized electrical parts,
assemblies, panels, or equipment.
c) The need for initial application and frequency of reapplication can only be established through offline characterization or routine electrostatic field measurements during normal operations using an
electrostatic fieldmeter or surface resistance measurement.
10.2

Relative humidity control

Relative humidity has an impact on the generation of static electricity and can augment an existing
program. The ESD program defined in this document is not dependent on humidity control. Humidity
control for ESD may be implemented if deemed necessary by the ESD coordinator.
10.3

Gloves and finger cots

When gloves or finger cots are required for contamination control, antistatic/dissipative gloves or finger
cots or cotton gloves should be used when handling ESDS devices.
Personnel wearing ESD safe gloves or finger cots must be aware of what they touch so not to transfer
contaminants (e.g., oils, grease, paste, inks, etc) onto ESDS devices. When in doubt change your gloves
or cots.

JEDEC Standard No. 625B


Page 17

11

Recommended ESD Audit Checklist

Area: ___________________________________

Date:__________

Auditor: _________________________________
ITEM

Y/N/NA

QUESTIONS (TEXT REFERENCE)

1.

Are all ESD measurement devices required by this standard in the calibration system?

2.

Are the daily ESD item checks of Table 2, Item 1 being performed?

3.

Is data available showing that the recommended weekly, monthly, quarterly, semiannual
and annual check items are continuously compliant? (Table 2-2 to 6)

4.

Are records of ESD item checks maintained for a minimum of two years?

5.

NOTE Continuously monitored items and visual checks do not require written records.
(5.3)
Are noncompliant measurements recorded as variables (the measured values) when the
measuring equipment is capable of providing variables or as attributes (fail) when the
equipment is only providing attributes? (5.3.b)

6.

Where unprotected ESDS devices are handled, are appropriate grounded static dissipative
(preferred) or conductive worksurfaces used? (Table 1-1)

7.

Are floor grounding methods used in areas where personnel or mobile ESD protective
workstations are not grounded by other means? (Table 1-2)

8.

Is each person handling unprotected ESDS devices grounded by either a wrist strap or
ESD protective footwear? (Table 1-3a, b)

9.

When wrist straps are used, are they providing a continuous electrical path from the user
to ESD ground? (Table 1-3)

10.

Do all ESD control product meet the acceptance requirement of this document?

11.

When personnel floor grounding methods are used, does the ESD protective footwear
(heel straps, toe straps or conductive shoes) provide a continuous electrical path from
both of the users feet to the ESD protective flooring or floor mat? (Table 1-3)

12.

Are ESD wrist straps used for grounding seated personnel?

13.

Are nonessential and personal items kept off of the ESD protective worksurfaces?
(Table 1-4a)

14.

Has a documented plan been implemented for process-required insulators?


c)

15.

Does the plan include methods to neutralize or reduce electrostatic fields to acceptable
levels? (Table 1-4b, c)

16.

When ESD protective smocks are used do the smocks cover all personal garment above
the waist except at the neck area? (Table 1-5)

(Table 2-1)

(6.3)

(Table 1-3)

(Table 1-4b,

JEDEC Standard No. 625-A


Page 18
11
ITEM

Recommended ESD Audit Checklist (contd)


Y/N/NA

QUESTIONS (TEXT REFERENCE)

17.

Are ESD protected areas identified with appropriate signs or markings?

18.

Does each ESD protective package have an appropriate ESD caution label?

19.

Are the ESD grounds compliant equipment/earth grounds?

20.

Are all ESD protected workstations individually connected to the defined ESD ground?
(6.3)

21.

Are static dissipative and conductive ESD protective worksurfaces each connected
directly to ESD ground? (6.4)

22.

When floor grounding devices (ESD protective footwear and/or mobile ESD protected
workstations) are being utilized, are compliant ESD protective flooring and/or mats used?
(6.5)

23.

Are firm fitting connecting devices such as metallic crimps, snaps and banana plugs used
for connections to the designated ESD ground points? (6.7)

24.

Does shelving that is being used as an ESD protected area or workstation meet all of the
requirements for an "ESD protected area or workstation" per clause 5 and Tables 1 and 2?
(6.8)

25.

When mobile equipment is used as an ESD protected workstation (e.g., cart, table), does
it meet the requirements for an ESD protected workstation per? (6.9)(Table 1-2)

26.

Are all ESDS devices in compliant ESD protective packaging per 4.13 and 8. When not at
an ESD protected area or workstation? (7.1)

27.

Has an ESD coordinator who is responsible for assuring that the requirements of this
standard are met been designated? (8.1)

28.

Is a periodic ESD audit performed of each operation that processes, handles or stores
ESDS devices to verify compliance to all requirements of this standard using the ESD
Audit Checklist or an equivalent checklist?

29.

(Table 1-6)
(5.6.3)

(6.1)

When non-compliances to the requirements of this standard are found, are:


_

they addressed according to company procedures.?

(8.3)

processing of ESDS devices through non-compliant areas and/or workstations suspended


until the noncompliance are corrected? (8.3.1)

30.

Are ESDS devices that have NOT been continuously handled, packaged and transported
according to this standard dispositioned per documented procedures? (8.3.2)

31.

Are rejected (e.g., electrical, mechanical) ESDS devices that are being returned to
suppliers, handled and shipped in accordance with the requirements of this standard?
(8.3.3)

32.

Are written records kept of all audits and ESD equipment calibrations for at least two (2)
years or as defined in the company quality management system? (8.4)

33.

Have all personnel handling ESDS devices received ESD handling training initially and at
least every 24 months thereafter to maintain proficiency? (9)

JEDEC Standard No. 625B


Page 19

Annex A (informative) Reference Documents


EOS/ESD-ADV1.0

EOS/ESD Association Glossary of Terms

EOS/ESD-S1

Standard for Protection of Electrostatic Discharge Susceptible


Items - Personal Grounding Wrist-Straps

MIL-STD-750

Test Methods for Semiconductor Devices

MIL-STD-883

Test Methods and Procedures for Microelectronics

MIL-STD-1686

Electrostatic Discharge Control Program for Protection of


Electrical and Electronic Parts, Assemblies and Equipment
(Excluding Electrically Initiated Explosive Devices)

MIL-PRF-87893

Workstations, Electrostatic Discharge Control

NAVSEA SE 003-AA-TRN-010

Electrostatic Discharge Training Manual

MIL-HDBK-263 Revision B

Electrostatic Discharge Control Handbook

JEDEC Standard No. 625B


Page 20

Annex B (informative) Differences between JESD625B and JESD625A


This annex briefly describes most of the changes made to entries that appear in this standard, JESD625B,
compared to its predecessor, JESD625-A (December 1999). If the change to a concept involves any
words added or deleted (excluding deletion of accidentally repeated words), it is included. Some
punctuation changes are not included.
Clause

Description of change

1&2

Per JM7, clause 1 and 2 were combined. Subsequently all clauses were renumbered. The
clauses litedin this annex refer to their number in JESD625A, followed by the clause
number used in this revision.

2.1/1.1

Applicable users were limited to semiconductor manufacturers and processing/testing


facilities. Distributors and Users are given option of using ANSI/ESD S20.20

2.2/1.2

Optoelectronic devices were added to applicable device types

2.3/1.3

Personnel safety was moved to Clause 2

3/2

Applicable documents were updated

4/3

Definitions were added for auxiliary ground, conductive material resistance, electrostatic
discharge shielding. Definitions were removed for conductive material resistivity,
electrostatic shielding. Definitions for ESDS, equipment ground, ESD ground, ESD-work
area, ESD-protected workstation, ESD protective worksurface, insulative material, static
dissipative material, static electricity, triboelectric charging, volume resistivity were
modified.

5/4

Section on calibration was removed since this is a function of the facility quality and
maintenance system

5.1/4.1

Continuous e-field monitors were added . Requirements on acceptable electric fields


near sensitive devices were added

6.1/5.1

The following changes were made in Table 1 (Minimum requirements for ESD protected
areas and workstations:
1.

Static dissipative range was established for protective worksurfaces. Conductive


surfaces are allowed but not recommended
3. Specific current limit removed
4. Maximum electrostatic fields specified at 2.5cm and 30cm.
7. Equipment and bonding requirements per ANSI/ESD S6.1added
Air ionization removed from this Table 1 because it did contain a specific minimum
requirement
Figure 1 was modified to show preference for using equipment rather than auxiliary
(formerly called earth) ground.

JEDEC Standard No. 625B


Page 21

Annex B (informative) Differences between JESD625B and JESD625A (contd)


6.2/5.2

This section heading was added Compliance Verification Baseline. The following
changes were made in Table 2 (ESD protective item checks)
3. Monthly checks Modified electrostatic field checks
4. Quarterly checks ESD ground continuity changed from 1 ohm to 2 ohms
Removed NOTE on measuring resistor in the worksurface to ground connection as these
resistors are not recommended

6.5.3/5.5.3

Continuous wrist strap and workstation monitors This section was expanded to add
monitor types

6.5.4/5.5.4

ESD Protective Smocks was moved from clause 11

6.6/5.6

Air Ionization Deployment was moved from clause 11

6.7.1/5.7.1

Reference to EIA-471 ESD caution symbol was removed.

6.7.2/5.7.2

Reference to ANSI/ESD S8.1 ESD caution symbol was added

7.1/6.1

Reference to NFPA-70 replaced by ANSI/ESD S6.1

7.1.1/6.1.1

Referenced to earth ground replaced by auxiliary ground. Bonding resistance between


equipment and auxiliary ground is specified

7.1.2/6.1.2

NOTE 2 removed. Relevant standards are quoted in other sections

7.2/6.2

Section on Safety Review moved to note in this section

7.3/6.3

Worksurface resistance ranges updated and consistent with Table 1. Note added
explaining that there should not be a discrete resistor in the path to ground

8.3/7.3

Term antistatic removed. Note on shelf life moved to body of section. Section on
Wafer and die packing removed. Other parts of this section cover die and wafers are out
of scope.

9.2/8.2

Title changed from Auditing to Frequency. Note referring to checklist removed.

10/9

Maximum re-training interval changes from one to two years. Note removed.

11/10

Air ionization and ESD protective smocks sections moved to Section 6

12/11

Audit Checklist modified to be compatible with changes in the document

JEDEC Standard No. 625B


Page 22

S-ar putea să vă placă și