Super Switch (Takeover Module)

INSTALL INSTRUCTIONS
The2GIGTAKE345SuperSwitchis2GIGswirelesstakeovermodule.Thisunitwas
designedtoconvert8hardwiredzonesintoeightwirelesszones,makeinstallation
simple,andworkwithexisting12voltcontrolpanels.Themoduleistobemounted
nexttotheexistingControlPanelwherethehardwiredzonesareconnected.Allof
thezonesontheSuperSwitchactassupervisedwirelesszones.
IMPORTANT: Ifthecontrolpanelhasbeenremovedthena12voltpower
supplywithbatterybackupisrequired(notsupplied).

Box Contents

TakeoverModule
MountingPlate
2Phillipsheadscrews
2Plasticdrywallanchors

PROGRAMMING
Thefollowingstepsareguidelinesforprogramming(learning)theSuperSwitchinto
the2GIGControlPanel.Scrollbetweenop onsusingtheandarrows.Moveto
thepreviousornextpromptbypressingtheandarrows.
1 SelectRFsensor#(01to48).AssigntheTakeoverModuletoanewzone.
(Terminals18)
2 SelectRFsensortype.
(01)Exit/Entry
(02)Exit/Entry
(03)Perimeter
(04)InteriorFollower
3 SelectRFequipmenttype.
4 SelectRFsensorequipmentcode.Enter0873forthe2GIGTAKE345module.
5 EnterRFsensorserialnumber(7digits).
ManualEntry:Typeinthelast7digitserialnumberthatendsin1(XXX
XXXX1)thatisfoundonthebackoftheSuperSwitch(thisistheserialnumber
forZone1).
Foreachadditionalzone,addadigittotheendoftheserialnumber.For
example,Zone(terminal)2willbe(XXXXXX2)
AutoEntry:WiththepanelinLearninmode(pressShiftthenLearn)tripthe
zonethatyouwanttolearnin.ThecorrectTXIDshouldappear.Acceptthe
correctTXIDbypressingok.
Remembertopressthearrowtocontinuethroughthe
systemconfigurationprompts.
6 SelectRFsensorequipmentage.
(0)new(productisnew)
7 SelectRFsensorloopnumber(1).
(1)1
8 SelectRFsensor1dialerdelay.
(0)disabled
(1)enabled
9 ConstructRFsensordescriptor.PressInsertthenpressanynumberbetween
002and255toaddaword.Forexample,ifyouwantedtonamethisTakeover
ModuleasWirelessSensorTool,pressInsertthenpress252forWIRELESS.
PressInsertthenpress191forSENSOR.PressInsertthenpress233forTOOL.
10 SelectRFsensorreports(0to1).
(0)disabled(sensordoesNOTreporttothecentralstation)
(1)enabled(sensorreportstothecentralstation)
11 SelectRFsensorsupervised(0to1).
(0)disabled(sensordoesNOTreportlossofsupervisionorlowbattery)
(1)enabled(sensorreportslossofsupervisionorlowbattery)
12 SelectRFsensorchime(0to13).
(0)disabled(panelwillnotchimewhensensorisactivated)
(113)enabled(selectsavoiceand/orchimetosoundwhensensorisactivated)
13 Toprogramanothersensor,clicknext.
14 Toexitprogramming,clickskipthenendandexit.Uponexit,
thepaneltakesafewsecondstoreset.
FORUL/ETLListedInstallationsusethefollowingequipment:
Altronix(TM)powersupply/chargermodel#AL100ULwithan
Altronix(TM)plugintransformer,model#TP1620andaPower
SonicModelPS121212Volt1.4AmpHourrechargeablesealed
leadacidbatteryorequivalent.See"UsingtheAltronixPowerSupply"onpage3.

Monitoring the Battery


TheSuperSwitchwilloperateontheconnectedbatteryifthereisanAC
failure,unlessthebatteryisnotcapableofsupplyingenoughpower.
TheSuperSwitchmonitorsthebatterytoensureitisoperational.When
theSuperSwitchdetectsabatteryvoltagebelownormallevelfora
periodoftime,theSuperSwitchreportsalowbatteryforeachzone(if
programmedinstep11underProgramming).

Testing the Battery Voltage


IfyougetaLowBatteryIndicator,dothefollowing:
1 Testthebatterysvoltagewithavoltreadertoensurethat12voltsarepassing
throughtheswitch.
2 Ifthebatteryisfine,removepowerfromtheSuperSwitch(disconnectbattery
andAUXpowerterminal2).
3 RewiretheSuperSwitchbyconnectingthebatteryfirst.
4 AftertheSuperSwitchispoweredbythebattery,connectAUXpowerto
terminal2ontheSuperSwitch.
5 RemovepowerfromtheControlPanelandthenpoweruptheControlPanel.If
everythingisconnectedcorrectly,theLowBatteryindicatorshoulddisappear.
IMPORTANT: Ifthereisnoexistingsystem,thenuseyourownpowersupply
andgroupallofthegroundwirestogetherandconnectthemtothe
groundportontheSuperSwitch.

INSTALLING AND MOUNTING

ScrewthemountingbrackettoawallandattachtheSuperSwitch.Torelease
thebracket,pulluponthetabandslidethebracketdown.Mountthebracket
with2screws.MounttheSuperSwitchinRFrangeoftheControlPanel.

To Wire Super Switch with an Existing Power Source


*SeeFigure1onnextpage
1 RemoveACpowerfromexistingwiredpanel.
2 Removeleadsfrombatteryonexistingwiredpanel.
3 Withpowerremoved,wirethezonestotheSuperSwitch.Terminals310are
markedasZones18ontheSuperSwitchandarewherethezonesare
connected.Forexample,towirezone1ontheSuperSwitchtakethepositiveor
HIsideofthezoneofftheexistingpanelandplaceitinterminal3/Zone1on
theSuperSwitch.LeavethenegativesideortheLO(GND)sideofthezone
wiredtotheexistingControlPanel.
4 RepeatthisprocedureforallzonestobeconnectedtotheSuperSwitch.
TIP: AnoptionistoremoveallLOwiresfromexistingpanel,groupthem
together,andconnectthemtothegroundport.
WARNING: THISISNOTFORUSEINAUL/ETLLISTEDINSTALLATION.

To Wire Super Switch without an Existing Power Source


See"UsingExistingSystemWiring"onpage3.
*SeeFigure2onnextpage
IMPORTANT: BeforeconnectingpowertotheSuperSwitch,wirethezones
totheSuperSwitch.Terminals310aremarkedasZones18ontheSuper
Switch.Forexample,towirezone1ontheSuperSwitchtakethepositive
orHIsideofthezoneplaceitinterminal3/Zone1ontheSuperSwitch.
1 RepeataboveforallzonestobeconnectedtotheSuperSwitch.
2 GroupallLO/(GND)wirestogetherandconnectthemtoterminal1/G(GND
PortoftheSuperSwitch.
WARNING: DONOTPLUGTHEPOWERSUPPLY/CHARGERPLUGIN
TRANSFORMERINTOANOUTLETCONTROLLEDBYASWITCH.

Powering the Super Switch and Other Devices


1

TheSuperSwitchhastwowiresattachedRED(+)andBLACK().Connectthe
Redwiretotheredterminalandtheblackwiretotheblackterminalonthe
existingControlPanelsbattery.
2 ConnectthewiresfromtheexistingControlPanelforthebatteryintothe
spadeslugsontopofthewiresfromtheSuperSwitchthatisnowconnectedto
thebattery.
3 IFUSINGANEXISTINGPOWERSOURCE:WiretheexistingpanelsAUXpower
outtoterminal2/12VportontheSuperSwitch.IfyouareusingtheSuper
SwitchwithPIRs,GlassBreakDetectors,orotherdevicesthatneedpower,then
theymustreceivepowerfromtheAUXpowerontheexistingControlPanel.
ReconnectACpowertoexistingpanel.
NOTE: RemoveallotherdeviceswiredtoAUXpowerontheexistingControl
Panel(suchaskeypadsoranyotherunuseddevicesrequiringpower).
WARNING: THISISNOTFORUSEINAUL/ETLLISTEDINSTALLATION.
2013 2GIG by Linear Corporation. All Rights Reserved. 1

Figures 1 and 2

2 2013 2GIG by Linear Corporation. All Rights Reserved.

Using Existing System Wiring

Using the Altronix Power Supply

2013 2GIG by Linear Corporation. All Rights Reserved. 3

Important to Remember
1
2

AllofthezonesontheSuperSwitcharenormallyclosedzones.
Themaximumloopresistancecannotexceed3Kohms(Iftheloopresistance
exceeds3Kohmsandtheexistingpanelusedendoflineresistance,thenthe
endoflineresistormayberemoved).
3 Differentcontrolpanelshavedifferentterminalsforeachzoneandauxpower.
Pleaserefertothewiringdiagramsthatcamewiththeexistingpanels.For
example,theHIsideofZone1Zone8onaVistapanelistypicallyterminals
8,11,12,14,15,17,18,and20.AUXpositiveistypicallyterminal5onaVista
panel.
WARNING: TheSuperSwitchCANNOTbeusedtomonitoranytypeoffire
orCODetectionZones.

Specifications
WirelessSignalRange
CodeOutputs
TransmitterFrequency
TransmitterFrequency
Tolerance
TransmitterBandwidth
ModulationType
UniqueIDCodes
SupervisoryInterval
PeakFieldStrength
SensorDimensions(LxWxH)
Weight(includingbracket)
HousingMaterial
Color
OperatingTemperatureLimits
RelativeHumidity
OperatingVoltage
IncludedAccessories

350ft,openair,with2GIGWirelessControlPanel
Foreachof8serializedzones:Fault;Restore;
Tamper;LowBattery
345.000MHz(crystalcontrolled)
15kHz

Limited Warranty
This2GIGTechnologiesproductiswarrantedagainstdefectsin
materialandworkmanshipfor2years.Thiswarrantyextendsonlyto
wholesalecustomerswhobuydirectfrom2GIGTechnologiesor
through2GIGTechnologiesnormaldistributionchannels.2GIG
Technologiesdoesnotwarrantthisproducttoconsumers.Consumers
shouldinquirefromtheirsellingdealerastothenatureofthedealers
warranty,ifany.
Therearenoobligationsorliabilitiesonthepartof2GIGTechnologies
forconsequentialdamagesarisingoutoforinconnectionwithuseor
performanceofthisproductorotherindirectdamageswithrespectto
lossofproperty,revenue,orprofit,orcostofremoval,installation,or
reinstallation.Allimpliedwarrantiesforfunctionality,arevalidonly
untilthewarrantyexpires.This2GIGTechnologiesWarrantyisinlieu
ofallotherwarrantiesexpressedorimplied.

24kHz
AmplitudeShiftKeyingOn/OffKeying(ASKOOK)
Overonemilliondifferentcodecombinations
70minutes
Typical50,000uV/mat3m
3.54x2.56x1.13in.(9.0x6.5x2.9cm)
2.85oz.(80.8g)
ABSplastic
White
32to120F(0to49C)
595%NonCondensing
916voltsDC,50mA
Mountingplate,2Phillipsheadscrews,2plastic
drywallanchors

Regulatory Compliance
ThisdevicecomplieswithPart15oftheFCC'sRules.Operationis
subjecttothefollowingtwoconditions:
1.Thisdevicemaynotcauseharmfulinterference,and
2.Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
Thisequipmenthasbeentestedandfoundtocomplywiththelimits
foraClassBdigitaldevice,pursuanttoPart15oftheFCCRules.These
limitsaredesignedtoprovidereasonableprotectionagainstharmful
interferenceinaresidentialinstallation.
Thisequipmentgenerates,usesandcanradiateradiofrequency
energyand,ifnotinstalledandusedinaccordancewiththe
instructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterference
willnotoccurinaparticularinstallation.Ifthisequipmentdoescause
harmfulinterferencetoradioortelevisionreception,whichcanbe
determinedbyturningtheequipmentoffandon,theuseris
encouragedtotrytocorrecttheinterferencebyoneormoreofthe
followingmeasures:
Reorientorrelocatethereceivingantenna.
Increasetheseparationbetweentheequipmentandreceiver.
Connecttheequipmentintoanoutletonacircuitdifferentfrom
thattowhichthereceiverisconnected.
Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
ThisproductcomplieswithFCCradiationexposurelimitsforan
uncontrolledenvironment.Avoidoperatingthisproductatadistance
lessthan20cmfromuser.
Caution:Anychangedormodificationsnotexpresslyapprovedbythe
partyresponsibleforcompliancecouldvoidtheuser'sauthorityto
operatethisequipment.

FortechnicalsupportintheUSAandCanada:
8552GIGTECH(8552444832)
Email:techsupport@2gig.com
Internet:dealer.2gig.com
Visitwebsitefortechnicalsupporthoursofoperation
FortechnicalsupportoutsideoftheUSAandCanada:
Contactyourregionaldistributor
Visitdealer.2gig.comforalistofdistributorsinyourregion
PN:IPM104702Rev.D