Automation Portal
Author
Slot
Lenovo
1
Description
Firmware version
V1.5
General\Identification & Maintenance
Plant designation
Location identifier
Additional informa
tion
PROFINET interface [X1]\General
Name
PROFINET interface_1
Author
Lenovo
PROFINET interface [X1]\Ethernet addresses\Interface networked with
Subnet:
Not connected
PROFINET interface [X1]\Ethernet addresses\IP protocol
Set IP address in the project
IP address:
192.168.0.1
Use router
False
PROFINET interface [X1]\Ethernet addresses\PROFINET
PROFINET device
False
Generate PROFINET True
name is set directly
device name auto
at the device
matically
Converted name:
plcxb1d0ed
Device number:
0
PROFINET interface [X1]\Time synchronization\NTP mode
Enable time syn
False
IP addresses
chronization via NTP
server
Server 2
0.0.0.0
Server 3
0.0.0.0
Update interval
10s
PROFINET interface [X1]\Operating mode
IO controller
True
IO system
IO device
False
PROFINET interface [X1]\Advanced options\Interface options
Call the user pro
False
Support device re True
gram if communica
placement without
tion errors occur
exchangeable medi
um
Use IEC V2.2 LLDP
False
Send keepalives for 30s
mode
connections
PROFINET interface [X1]\Advanced options\Media redundancy
MRP domain
PROFINET interface [X1]\Advanced options\Real time settings\IO communication
Send clock:
1.000ms
PROFINET interface [X1]\Advanced options\Real time settings\Synchronization
RT class:
RT,IRT
PROFINET interface [X1]\Advanced options\Real time settings\Real time options
Calculated band
0.000ms
width for cyclic IO
data:
PROFINET interface [X1]\Advanced options\Port [X1 P1 R]\General
Name
Port_1
Author
Lenovo
PROFINET interface [X1]\Advanced options\Port [X1 P1 R]\Port interconnection\Local port:
Local port:
PLC_1\PROFINET interface_1
Medium:
Copper
[X1]\Port_1 [X1 P1 R]
Comment
Installation date
6ES7 511-1AK00-0AB0
2014-10-31 03:11:48.122
Comment
Subnet mask:
255.255.255.0
PROFINET device
name
plc_1
Server 1
0.0.0.0
Server 4
0.0.0.0
Device number
Comment
Cable name:
---
Comment
Totally Integrated
Automation Portal
PROFINET interface [X1]\Advanced options\Port [X1 P2 R]\Port interconnection\Local port:
Local port:
PLC_1\PROFINET interface_1
Medium:
Copper
[X1]\Port_2 [X1 P2 R]
Cable name:
---
Address gaps
False
Address of system 1
memory byte (MBx)
First cycle
Always 1 (high)
Always 0 (low)
Address of clock
0
memory byte (MBx)
2.5 Hz clock
1 Hz clock
10 Hz clock
2 Hz clock
0.625 Hz clock
Acknowledgement
False
False
False
False
Permit access only
with HTTPS
False
Update interval
0s
Alarm class
No Acknowledgement
No Acknowledgement
No Acknowledgement
No Acknowledgement
User rights
Fragment DB number
334
Totally Integrated
Automation Portal
Display\General\Display language
Default language on English
display
Display\Automatic update
Time until update
5 seconds
Display\Password\Display protection
Enable display pro False
Password
tection
Time until automat 15 minutes
ic logoff
Display\User-defined logo\User-defined logo
User-defined logo False
Adapt logo
page
OriginalLogo
User interface languages
Assign project language
English (United States)
English (United States)
English (United States)
English (United States)
English (United States)
English (United States)
English (United States)
English (United States)
English (United States)
English (United States)
English (United States)
Time of day\Local time
Time zone
(UTC) Dublin, Edinburgh, Lisbon,
London
Time of day\Daylight savings
Enable daylight sav True
Difference between
ings time change
standard and day
over
light savings time
Time of day\Daylight savings\Start of daylight saving time
Selection of the
Last
Selection of the
week
weekday
at
01:00 a.m.
Time of day\Daylight savings\Start of standard time
Selection of the
Last
Selection of the
week
weekday
at
02:00 a.m.
Protection
Level of protection Full access (no protection)
System power supply\General
General
Connection to supply voltage L+
System power supply\\Power segment overview
Module
Slot
PM 70W 120/230VAC
0
PLC_1
1
Summary
Configuration control\Configuration control for central configuration
Allow to reconfigure 0
the device via the
user program
Confirm password
False
Company logo
60mins
Sunday
of
March
Sunday
of
October
Supply/consumption
0.00W
10.00W
10W
Totally Integrated
Automation Portal
Data type
Bool
Bool
Type
OB
Comment
Default value
Language
Family
Comment
Initial call of this OB
=True, if remanent data are available
LAD
Totally Integrated
Automation Portal
Totally Integrated
Automation Portal
PLC_1 [CPU 1511-1 PN] / PLC tags / Default tag table [44]
PLC tags
PLC tags
Name
Data type
Address
Retain
Visible in
HMI
Accessible Comment
from HMI
Totally Integrated
Automation Portal
PLC_1 [CPU 1511-1 PN] / PLC tags / Default tag table [44]
User constants
User constants
Name
Data type
Value
Comment
Totally Integrated
Automation Portal
Totally Integrated
Automation Portal
Address
Display format
Force value
Comment
Totally Integrated
Automation Portal
Totally Integrated
Automation Portal
Totally Integrated
Automation Portal
Totally Integrated
Automation Portal