Solid and value-for-money charging system from HOPPECKE

Voltage [V/C]

WSA-charging characteristic acc. to ZVEI


Characteristic points:
13-18 A/100 Ah at 2.00 V/C (100%)
8.0-12 A/100 Ah at 2.40 V/C (62-66%)
3.5-6.0 A/100 Ah at 2.75 V/C (27-33%)
Tolerance of the characteristic -50 mV/C
WSA acc. to ZVEI
+/- 50 mV/C tolerance

Assignment table B-F15 FS (24 V)


Battery

8h

9h

10 h

11 h

12 h

13 h

14 h

[Ah]

charge

charge

charge

charge

charge

charge

charge

120
160
180
190
210
220
225
240
270
280
300
315
320
330
360
400
420
440
450
480
525
540
550
560
600
630
640
660
700
720
735
750
770
800
810
840
880
900
945
960
980
990
1050
1080
1100
1120
1200
1260
1350
1400

24/30

24/45
24/45
24/45
24/55
24/55
24/55
24/65
24/65
24/65
24/75
24/75

24/95
24/95
24/95
24/110
24/110
24/110
24/110
24/125
24/125

24/185
24/185
24/185

24/30
24/30

24/45
24/45
24/45
24/55
24/55

24/65
24/65
24/65
24/75
24/75

24/95
24/95
24/110
24/110
24/110
24/110
24/125
24/125
24/125
24/125

24/185
24/185
24/185
24/185
24/185
24/185

24/30

24/45

24/55
24/55
24/55
24/55
24/65
24/65
24/75
24/75

24/95
24/95
24/95
24/110
24/110
24/110
24/110
24/125
24/125
24/125

24/185
24/185
24/185
24/185
24/185
24/185

24/30
24/30

24/45
24/45
24/45

24/55
24/55
24/65
24/65
24/65
24/75
24/75

24/95
24/95
24/95
24/110
24/110
24/110
24/110
24/110
24/110
24/125
24/125
24/125

24/185
24/185
24/185
24/185

24/30
24/30

24/45
24/45
24/45
24/45
24/55
24/55

24/65
24/65
24/65
24/75
24/75
24/75
24/75

24/95
24/95
24/95
24/110
24/110
24/110
24/110
24/110
24/110
24/125
24/125
24/125

24/185
24/185

24/30
24/30
24/30

24/45
24/45
24/55
24/55
24/55
24/65
24/65
24/65
24/75
24/75
24/75

24/95
24/95
24/95
24/95
24/110
24/110
24/110
24/110
24/110
24/110
24/125
24/125
24/125
24/125

24/185
24/185

Type [V] / [A]


24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24

V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V

24/30

24/45
24/45

24/55
24/55
24/55
24/65
24/65
24/75
24/75
24/75

24/95
24/95
24/95

24/110
24/110
24/110
24/125
24/125
24/125
24/125
24/125

24/185
24/185
24/185
24/185

The example above is for 24 v assignment. For 48 V and 80 V please consult our HOPPECKE team.

INominal Charger [%]

HOPPECKE Batterien GmbH & Co. KG Bontkirchener Str. 1, 59929 Brilon, Germany
Further Information: http://www.HOPPECKE.com

Printed in Germany

Benefits of these chargers:


advantageous price
tested in accordance with Quality Specifications for
Chargers for HOPPECKE Lead-Acid Traction Batteries
may be used within limits for various battery capacities
by means of defined cut-off factor du/dt (use in shifts up
to 8 h charging time also possible)
comply with ZVEI (German electrical standards) in
respect of safety cut-off and charging characteristic
more limited variations in charging current with mains
power fluctuations as compared with Wa chargers, since
the charging curve is steeper (see diagram below)
optimal secondary charging current for assignments up
to 12.5 A//100 Ah
cut-off factor is independent of battery age and
manufacturer
assignments to battery capacity are independent of
charging times. In future, no longer necessary to decide
between Wa or W0Wa
wall mounting facility for units T82/83

F15 FS functional description


the microprocessor-controlled charging system monitors
the charging process entirely automatically
charging time is automatically matched to battery depth
of discharge
disconnection is effected via the du/dt control
during longer standby periods, the battery is kept ready
for use by automatic refresh charges
in the event of failure, both battery and chargers are
protected by higher-level safety cut-outs
the charging electronics recognise slightly sulphated
batteries and charge them up fully

trak basic Battery chargers for vented lead-acid traction batteries EN/04.2002/3 He

F15 FS charger
unregulated chargers permitting trouble-free charging of
lead-acid traction batteries
they allow rapid and controlled charging of the battery
as required by the customer
they have a permanently set charging characteristic as
specified in the ZVEI leaflet Battery charger assignment
for vented lead-acid traction batteries
modular design to facilitate customer servicing and
enhance user flexibility
time-delayed start of charging after battery connection
and switch-on of charging
safety cut-offs up to 2.4 V per cell. Time-controlled
disconnections are also implemented