Documente Academic
Documente Profesional
Documente Cultură
TS09080083-ST
Manufacturers name hTC has been shown on front enclosure, please refer to photos.
Below sentence is necessary while the flammability class HB enclosure is used.
For use only with power supply, mfr. Phihong, Type PSC05R-050, PSC05R-050 PH, PSAA05X-050,
PSAI05R-050YYY or PSAI05X-050YYY, mfr. Delta, Type ADP-5FH X, EADP-5GB X, EADP-5GB E or
EADP-5LB A, mfr. Tamura, Type JHA050100Uabb or mfr. HTC, Type TC P300.
For use only with battery pack, mfr. Formosa Electronic Industries Inc. (hTC INNOVATION), Type
BB81100.
For use only with car adaptor, mfr. Phihong, Type CLM10D-050, mfr. Hwa Ying, Type AP-03, or mfr. L&K,
Type G12PCL-***.
Note:
The above markings are the minimum requirements required by the safety standard. For the final
production samples, the additional markings which do not give rise to misunderstanding may be added.
Page 3 of 95
TS09080083-ST
Summary of testing:
The sample(s) tested complies with the requirements of IEC 60950-1: 2001 and EN 60950-1: 2001 + A11:
2004.
1.6.2
1.7.13
2.2.2
2.2.3
4.2.4
4.2.6
4.2.7
4.3.8
4.5.1
5.3
Page 4 of 95
TS09080083-ST
Hand-held (Transportable)
Continuous
No
Class III
IPX0
P (Pass)
F (Fail)
Testing
Date of receipt of test item .......................... :
General remarks
This report is not valid as a CB Test Report unless appended by an approved CB Testing
Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
The test result presented in this report relate only to the object(s) tested.
This report shall not be reproduced, except in full, without the written approval of the issuing testing
laboratory.
(see Appendix #) refers to additional information appended to the report.
(see appended table #) refers to a table appended to the report.
Throughout this report a comma (point) is used as the decimal separator.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between
Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the
agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first
be approved in writing by Intertek. The observations and test results in this report are relevant only to the
sample tested. This report by itself does not imply that the material, product, or service is or has ever been
under an Intertek certification program.
When determining the test conclusion, the Measurement Uncertainty of test has been considered.
Additional information
Additional special deviations of CN (China) and JP (Japan) of IEC 60950, 3rd ed. are checked.
Compliance with the National requirements of (countries) as given in CB Bulletin (112A) dated
December 2006 and IECEE website dated July 2009 were also confirmed.
Page 5 of 95
TS09080083-ST
Page 6 of 95
TS09080083-ST
Requirement Test
GENERAL
1.5
Components
1.5.1
General
Result Remark
Verdict
1.5.2
1.5.3
Thermal controls
N/A
1.5.4
Transformers
N/A
1.5.5
Interconnecting cables
1.5.6
N/A
1.5.7
N/A
1.5.7.1
General
N/A
1.5.7.2
Bridging capacitors
N/A
1.5.7.3
Bridging resistors
N/A
1.5.7.4
Accessible parts
N/A
1.5.8
1.6
Power interface
1.6.1
N/A
N/A
Page 7 of 95
TS09080083-ST
Requirement Test
Result Remark
1.6.2
Input current
1.6.3
5 Vdc
1.6.4
Neutral conductor
N/A
1.7
1.7.1
Power rating
N/A
Same as above
N/A
Same as above
N/A
Same as above
N/A
Same as above
N/A
hTC
N/A
PB81***
N/A
Verdict
N/A
1.7.2
Safety instructions
1.7.3
N/A
1.7.4
N/A
1.7.5
N/A
1.7.6
N/A
1.7.7
Wiring terminals
N/A
Page 8 of 95
TS09080083-ST
Requirement Test
1.7.7.1
N/A
1.7.7.2
N/A
1.7.7.3
N/A
1.7.8
1.7.8.1
1.7.8.2
Colours .............................................................. :
1.7.8.3
1.7.8.4
N/A
1.7.9
N/A
1.7.10
N/A
1.7.11
N/A
1.7.12
Language ........................................................... :
1.7.13
Durability
1.7.14
Removable parts
Result Remark
Verdict
Page 9 of 95
TS09080083-ST
Requirement Test
Result Remark
1.7.15
Replaceable batteries
Language ............................................................ :
1.7.16
No such area
N/A
1.7.17
N/A
Verdict
Page 10 of 95
TS09080083-ST
Requirement Test
Result Remark
2.1
2.1.1
2.1.1.1
Verdict
N/A
N/A
N/A
N/A
N/A
2.1.1.2
N/A
2.1.1.3
N/A
N/A
2.1.1.5
2.1.1.6
Manual controls
N/A
2.1.1.7
N/A
No such area
N/A
2.1.3
N/A
2.2
SELV circuits
2.2.1
General requirements
2.2.2
P
All accessible voltages are less
42.4 Vpeak or 60 Vdc and are
classified as SELV circuits
Page 11 of 95
TS09080083-ST
Requirement Test
Result Remark
2.2.3
2.2.3.1
2.2.3.2
N/A
2.2.3.3
N/A
2.2.4
Connection of SELV circuits to other circuits ...... : SELV circuits only connected to
SELV circuits
2.3
TNV circuits
2.3.1
Limits
N/A
N/A
N/A
N/A
Verdict
N/A
2.3.5
N/A
2.4
2.4.1
General requirements
2.4.2
Limit values
No considered
N/A
N/A
Page 12 of 95
TS09080083-ST
Requirement Test
Result Remark
2.4.3
2.5
Verdict
N/A
N/A
N/A
N/A
N/A
N/A
Note:
The output of battery pack, the output of approved external power supply unit and the output of approved car
adaptor which listed in the table 1.5.1 are complied with Limited Power Source.
2.6
2.6.1
Protective earthing
2.6.2
Functional earthing
N/A
2.6.3
N/A
2.6.3.1
General
N/A
2.6.3.2
N/A
2
N/A
N/A
2.6.3.4
N/A
2.6.3.5
N/A
Page 13 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
N/A
N/A
2.6.5
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
N/A
2.6.5.3
N/A
2.6.5.4
N/A
2.6.5.5
N/A
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
N/A
2.6.5.8
N/A
2.7
2.7.1
Basic requirements
N/A
N/A
2.7.2
N/A
2.7.3
N/A
2.7.4
N/A
2.7.5
N/A
2.7.6
N/A
2.8
Safety interlocks
2.8.1
General principles
N/A
Page 14 of 95
TS09080083-ST
Requirement Test
Result Remark
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
N/A
2.8.7.1
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
2.9.1
2.9.2
Humidity conditioning
Verdict
N/A
Considered
2.9.3
Grade of insulation
2.10
2.10.1
General
2.10.2
N/A
2.10.3
Clearances
N/A
2.10.3.1
General
N/A
2.10.3.2
N/A
2.10.3.3
N/A
2.10.3.4
N/A
2.10.4
Creepage distances
N/A
CTI tests.............................................................. :
Page 15 of 95
TS09080083-ST
Requirement Test
2.10.5
Solid insulation
N/A
2.10.5.1
N/A
2.10.5.2
N/A
2.10.5.3
Result Remark
Verdict
Printed boards
N/A
N/A
N/A
Wound components
N/A
N/A
N/A
2.10.6
N/A
2.10.6.1
General
N/A
2.10.6.2
N/A
2.10.6.3
Thermal cycling
N/A
2.10.6.4
N/A
2.10.6.5
2.10.6.6
2.10.5.4
2.10.8
N/A
N/A
N/A
N/A
2.10.9
N/A
2.10.10
N/A
Page 16 of 95
TS09080083-ST
Requirement Test
Result Remark
3.1
General
3.1.1
3.1.2
3.1.3
3.1.4
Insulation of conductors
3.1.5
No such insulator
N/A
3.1.6
N/A
3.1.7
N/A
3.1.8
N/A
3.1.9
Termination of conductors
N/A
10 N pull test
N/A
3.1.10
Sleeving on wiring
3.2
3.2.1
3.2.1.1
N/A
3.2.1.2
N/A
Verdict
N/A
N/A
Page 17 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
3.2.2
N/A
3.2.3
N/A
Appliance inlets
N/A
3.2.5
N/A
3.2.5.1
N/A
Type .................................................................... :
N/A
3.2.6
N/A
3.2.7
N/A
3.2.8
Cord guards
N/A
3.2.9
3.3
3.3.1
Wiring terminals
3.3.2
N/A
3.3.3
Screw terminals
N/A
3.3.4
N/A
N/A
N/A
N/A
3.3.6
N/A
3.3.7
N/A
Page 18 of 95
TS09080083-ST
Requirement Test
3.3.8
Stranded wire
3.4
3.4.1
General requirement
3.4.2
Disconnect devices
N/A
3.4.3
N/A
3.4.4
N/A
3.4.5
N/A
3.4.6
N/A
3.4.7
Three-phase equipment
N/A
3.4.8
N/A
3.4.9
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
N/A
3.5
Interconnection of equipment
3.5.1
General requirements
3.5.2
3.5.3
Result Remark
Verdict
N/A
SELV to SELV
N/A
P
P
N/A
Page 19 of 95
TS09080083-ST
Requirement Test
PHYSICAL REQUIREMENTS
4.1
Stability
Angle of 10
Result Remark
Verdict
N/A
N/A
4.2
Mechanical strength
4.2.1
General
4.2.2
N/A
4.2.3
N/A
4.2.4
4.2.5
Impact test
See below
N/A
Fall test
N/A
Swing test
N/A
4.2.6
Drop test
4.2.7
4.2.8
N/A
N/A
4.2.9
N/A
4.2.10
N/A
4.3
4.3.1
Page 20 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
4.3.2
No hazards
N/A
4.3.3
Adjustable controls
N/A
4.3.4
Securing of parts
4.3.5
No mismatch of connectors,
plugs or sockets possible
N/A
4.3.6
N/A
N/A
N/A
4.3.7
N/A
4.3.8
Batteries
N/A
4.3.10
N/A
4.3.11
N/A
4.3.12
N/A
N/A
N/A
4.3.13
4.3.13.1
General
4.3.13.2
Ionizing radiation
Measured radiation (pA/kg) ................................ :
P
P
N/A
Page 21 of 95
TS09080083-ST
4.3.13.3
Requirement Test
Result Remark
Verdict
4.3.13.5
N/A
N/A
N/A
P
4.3.13.6
4.4
4.4.1
General
4.4.2
N/A
4.4.3
N/A
4.4.4
N/A
4.5
Thermal requirements
4.5.1
Maximum temperatures
4.5.2
N/A
4.6
Openings in enclosures
4.6.1
N/A
N/A
N/A
Page 22 of 95
TS09080083-ST
Requirement Test
Result Remark
4.6.2
Verdict
N/A
4.6.4
4.6.5
N/A
P
N/A
4.7
Resistance to fire
4.7.1
N/A
4.7.2
N/A
4.7.2.1
N/A
4.7.2.2
4.7.3
Materials
4.7.3.1
General
4.7.3.2
4.7.3.3
4.7.3.4
4.7.3.5
N/A
4.7.3.6
N/A
P
N/A
P
Page 23 of 95
TS09080083-ST
Requirement Test
Result Remark
5.1
5.1.1
General
5.1.2
N/A
5.1.3
Test circuit
N/A
5.1.4
N/A
5.1.5
Test procedure
N/A
5.1.6
Test measurements
N/A
Verdict
N/A
5.1.7
5.1.8
N/A
5.1.8.1
N/A
N/A
5.1.8.2
5.2
Electric strength
5.2.1
General
5.2.2
Test procedure
N/A
No considered
N/A
N/A
Page 24 of 95
TS09080083-ST
Requirement Test
5.3
5.3.1
5.3.2
Motors
(see Annex B)
5.3.3
Transformers
5.3.4
Method c)
5.3.5
Electromechanical components
5.3.6
Simulation of faults
5.3.7
Unattended equipment
5.3.8
5.3.8.1
5.3.8.2
Result Remark
Verdict
N/A
P
N/A
P
N/A
Page 25 of 95
TS09080083-ST
Requirement Test
Result Remark
6.1
6.1.1
N/A
6.1.2
N/A
6.1.2.1
Requirements
N/A
Verdict
6.1.2.2
Exclusions ...........................................................:
N/A
6.2
6.2.1
Separation requirements
6.2.2
N/A
6.2.2.1
Impulse test
N/A
6.2.2.2
Steady-state test
N/A
6.2.2.3
Compliance criteria
N/A
6.3
N/A
Page 26 of 95
TS09080083-ST
Requirement Test
7.1
N/A
7.2
N/A
7.3
N/A
7.3.1
General
N/A
7.3.2
N/A
7.3.3
Impulse test
N/A
Result Remark
Verdict
Page 27 of 95
TS09080083-ST
Requirement Test
Result Remark
N/A
A.1
Flammability test for fire enclosures of movable equipment having a total mass
exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
N/A
A.1.1
Samples ..............................................................:
Verdict
A.1.2
N/A
A.1.3
N/A
A.1.4
N/A
Flame A, B, C or D .............................................:
A.1.5
Test procedure
N/A
A.1.6
Compliance criteria
N/A
A.2
Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
N/A
A.2.1
A.2.2
Conditioning of samples
N/A
A.2.3
Mounting of samples
N/A
A.2.4
N/A
Flame A, B or C ..................................................:
A.2.5
Test procedure
N/A
A.2.6
Compliance criteria
N/A
A.2.7
A.3
N/A
N/A
Page 28 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
A.3.1
Mounting of samples
N/A
A.3.2
Test procedure
N/A
A.3.3
Compliance criterion
N/A
B.1
General requirements
Position .............................................................. :
Vibrator motor
Manufacturer ...................................................... :
JINLONG
Type ................................................................... :
Z4TJGB1512403
B.2
Test conditions
B.3
Maximum temperatures
B.4
N/A
B.5
N/A
B.6
B.7
B.7.1
Test procedure
B.7.2
B.7.3
B.8
N/A
B.9
N/A
B.10
N/A
7 hours
N/A
The motors voltage not exceed
42.4 Vpeak or 60 Vdc
N/A
N/A
N/A
Page 29 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
Manufacturer ...................................................... :
Type ................................................................... :
C.1
Overload test
N/A
C.2
Insulation
N/A
N/A
N/A
D.1
Measuring instrument
N/A
D.2
N/A
N/A
N/A
N/A
G.1
N/A
G.2
N/A
G.2.1
AC mains supply
N/A
G.2.2
DC mains supply
N/A
G.3
N/A
G.4
N/A
G.5
N/A
G.6
N/A
N/A
Page 30 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
N/A
N/A
K.1
N/A
K.2
N/A
K.3
N/A
K.4
N/A
K.5
N/A
K.6
Stability of operation
N/A
L.1
Typewriters
N/A
L.2
N/A
L.3
Erasers
N/A
L.4
Pencil sharpeners
N/A
L.5
N/A
L.6
Motor-operated files
N/A
L.7
N/A
M.1
Introduction
N/A
M.2
Method A
N/A
M.3
Method B
N/A
M.3.1
Ringing signal
N/A
M.3.1.1
M.3.1.2
M.3.1.3
Page 31 of 95
TS09080083-ST
Requirement Test
Result Remark
M.3.1.4
M.3.2
N/A
M.3.2.1
N/A
M.3.2.2
Tripping device
N/A
M.3.2.3
N/A
N/A
N.1
N/A
N.2
N/A
ANNEX Q, BIBLIOGRAPHY
N/A
R.1
N/A
R.2
N/A
N/A
S.1
Test equipment
N/A
S.2
Test procedure
N/A
S.3
N/A
N/A
Verdict
N/A
Page 32 of 95
TS09080083-ST
Requirement Test
N/A
V.1
Introduction
N/A
V.2
N/A
V.3
N/A
V.4
N/A
N/A
W.1
N/A
W.1.2
Earthed circuits
N/A
W.2
N/A
W.2.1
Isolation
N/A
W.2.2
N/A
W.2.3
N/A
N/A
X.1
N/A
X.2
N/A
N/A
Y.1
N/A
Y.2
N/A
Y.3
N/A
Y.4
N/A
Result Remark
Verdict
Page 33 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
General
1.5.8
1.7.12
2.2.4
2.3.4
3.2.1.1
4.3.6
6.1.2.1
6.2.2.1
7.1
Annex H
Note 2
Note 2
Note
Note 2,3
Note
Note 1,2
Note
Note 2
Note
Note 2
1.6.1
2.6
2.3.2
2.7.1
3.2.3
4.7.2.2
6.1.2.2
6.2.2.2
Considered
Note
Note
Note 2, 7, 8
Note
Note 1, 2
Note
Note
Note
1.2.4.1
N/A
1.5.1
N/A
N/A
Page 34 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
1.5.8
N/A
1.7.2
N/A
N/A
Vigtigt!
Lederen med grn/gul isolation m kun tilsluttes
en klemme mrket
eller
If essential for the safety of the equipment, the
tag must in addition be provided with a diagram
which shows the connection of the other
conductors, or be provided with the following text:
For tilslutning af de vrige ledere, se
medflgende instalationsvejledning.
N/A
Page 35 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
N/A
N/A
1.7.12
N/A
N/A
Page 36 of 95
TS09080083-ST
Requirement Test
Result Remark
1.7.15
2.2.4
N/A
2.3.2
N/A
2.3.3
N/A
2.3.4
N/A
2.6.3.3
N/A
Verdict
P
Page 37 of 95
TS09080083-ST
Requirement Test
Result Remark
2.7.1
Verdict
N/A
Basic requirements
To protect against excessive current, shortcircuits and earth faults in PRIMARY CIRCUITS,
protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a),
b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as
parts of the equipment;
b) for components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch,
short-circuit and earth fault protection may be
provided by protective devices in the building
installation;
c) it is permitted for PLUGGABLE EQUIPMENT
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated
overcurrent and short-circuit protection in the
building installation, provided that the means
of protection, e.g. fuses or circuit breakers, is
fully specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be
regarded as providing protection in accordance
with the rating of the wall socket outlet.
S (GB): In the United Kingdom, to protect
The EUT is not direct plug-in
against excessive currents and short-circuits in
equipment
the PRIMARY CIRCUIT OF DIRECT PLUG-IN
EQUIPMENT, protective device shall be included
as integral parts of the DIRECT PLUG-IN
EQUIPMENT.
N/A
2.7.2
N/A
2.10.2
N/A
Page 38 of 95
TS09080083-ST
Requirement Test
Result Remark
2.10.3.1
3.2.1.1
Verdict
N/A
N/A
N/A
230/400 V, 16 A
250 V, 16 A
250 V, 16 A
S (DK): In Denmark, supply cords of singlephase equipment having a rated current not
exceeding 13 A shall be provided with a plug
according to the Heavy Current Regulations,
Section 107-2-D1.
CLASS I EQUIPMENT provided with socketoutlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with standard sheet DK 2-1a or DK
2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord
with a plug, this plug shall be in accordance with
the Heavy Current Regulations, Section 107-2D1 or EN 60309-2.
Page 39 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
N/A
N/A
N/A
N/A
Page 40 of 95
TS09080083-ST
Requirement Test
Result Remark
3.2.5.1
C: Replace
N/A
N/A
No wiring terminal
N/A
Verdict
1)
0,75
1,0
1,5
3.3.4
4.3.6
N/A
N/A
Page 41 of 95
TS09080083-ST
4.3.13.6
Requirement Test
Result Remark
Verdict
N/A
N/A
N/A
Page 42 of 95
TS09080083-ST
Requirement Test
(cont.)
Result Remark
Verdict
N/A
N/A
Page 43 of 95
TS09080083-ST
Requirement Test
(cont.)
Result Remark
Verdict
N/A
7.1
N/A
G.2.1
N/A
N/A
Page 44 of 95
TS09080083-ST
Requirement Test
Result Remark
Annex H
Verdict
N/A
Page 45 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
Annex ZA
Year
IEC 60050-151
IEC 60050-195
1998
IEC 60073
1996
IEC 60085
1984
IEC 60112
1979
IEC 60216-4-1
1990
Series
Series
IEC 60309
Series
Title
EN/HD
Year
EN 60065
+ corr. June
EN 60073
1998
1999
1996
HD 566 S1
1990
HD 214 S2
1980
HD
611.4.1.S1
1992
HD 21 1)
Series
HD 22 2)
Series
EN 60309
Series
Page 46 of 95
TS09080083-ST
Requirement Test
(cont.)
IEC 60317-43
1997
Series
IEC 60364-3
(mod)
IEC 60364-4-41
(mod)
1993
IEC 60384-14
1992 3)
1993
IEC 60417-1
IEC 60664-1
(mod)
1992
IEC 60695-2-2
1991
IEC 60695-2-11
2000
IEC 60695-2-20
1995
IEC 60695-10-2
1995
IEC 60695-11-3
2000
IEC 60695-11-4
2000
IEC 60695-11-10
1999
IEC 60695-11-20
1999
Result Remark
Specifications for particular types of
winding wires Part 43: Aromatic
polyimide tape wrapped round copper
wire, class 240
EN 60317-43
EN 60320
Verdict
1997
Series
HD 384-3 S2
1995
HD 384-4-41
S2
1996
EN 132400 4)
+A2
+A3
+A4
EN 60417-1
1994
1998
1998
2001
HD 625.1 S1
+ corr. Nov.
1996
1996
EN 60695-22
EN 60695-211
1994
2001
EN 6069511-10
1999
EN 6069511-20
1999
Page 47 of 95
TS09080083-ST
Requirement Test
(cont.)
IEC 60730-1
(mod)
1999
EN 60730-1
2000
IEC 60825-1
1993
EN 60825-1
+ corr.
February
+ A11
+corr. July
EN 60825-2
1994
1995
IEC 60825-2
2000
IEC 60825-9
1999
IEC 60851-3
1996
IEC 60851-5
1996
IEC 60851-6
1996
IEC 60885-1
1987
IEC 60990
1999
IEC 61058-1
2000
IEC 61965
ISO 178
2000
1993
ISO 179
Series
ISO 180
1993
ISO 261
1998
ISO 262
1998
ISO 527
Series
ISO 3864
ISO 4892
1984
Series
ISO 7000
1989
ISO 8256
1990
Result Remark
Verdict
1996
1997
2000
EN 60851-3
1996
EN 60851-5
1996
EN 60851-6
1996
EN 60990
1999
EN 61965
EN ISO 178
2001
1996
EN ISO 179
Series
EN ISO 180
2000
EN ISO 527
Series
EN ISO 4892
Series
EN ISO 8256
1996
Page 48 of 95
TS09080083-ST
Requirement Test
Result Remark
(cont.)
ISO
1994
ISO 9773
1998
EN ISO 9773
ITU-T
Recommendation K.17
1988
ITU-T
Recommendation K.21
2000
Verdict
1998
1) The HD 21 series is related to, but not directly equivalent with the IEC 60227 series.
2) The HD 22 series is related to, but not directly equivalent with the IEC 60245 series.
3) IEC 60364-4-41:1992 is superseded by IEC 60364-4-41:2001.
4) EN 132400, Sectional Specification: Fixed capacitors for electromagnetic interference suppression
and connection to the supply mains (Assessment level D), and its amendments are related to, but not
directly equivalent to IEC 60384-14.
Page 49 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
Annex ZZ
(normative)
Variations to IEC 60950-1:2001 for application in Australia
and New Zealand
ZZ1 Introduction
This Annex sets out variations between this Standard and IEC
60950-1:2001. These variations indicate national variations for
purposes of the IECEE CB Scheme and will be published in
the IECEE CB Bulletin. These variations are indicated within
the body of the Standard.
ZZ.2 Variations
Page 50 of 95
TS09080083-ST
Requirement Test
Result Remark
1.5.2
Verdict
P
N/A
3.2.3
Delete Note 2.
N/A
3.2.5.1
N/A
N/A
RATED CURRENT OF
EQUIPMENT
Nominal cross-
section area
AWG or Kcmil
(cross-section
area in mm2)
mm2
See note 2
1)
0,5
18 [0,8]
0,75
16 [1,3]
1,00
16 [1,3]
(1,0 )3)
1,5
14 [2]
Delete Note 1.
4.3.6
4.3.13.5
Page 51 of 95
TS09080083-ST
Requirement Test
4.7
Result Remark
Verdict
N/A
N/A
Page 52 of 95
TS09080083-ST
Requirement Test
4.7.201.1
General
Parts of non-metallic material shall be resistant to
ignition and spread of fire.
This requirement does not apply to decorative
trims, knobs and other parts unlikely to be ignited
or to propagate flames originating from inside the
apparatus, or the following:
Components that are contained in an enclosure
having a flammability category of FV-0 according
to AS/NZS 4695.707 and having openings only
for the connecting wires filling the openings
completely, and for ventilation not exceeding 1
mm in width regardless of length.
The following parts which would contribute
negligible fuel to a fire: small mechanical parts,
the mass of which does not exceed 4 g, such as
mounting parts, gears, cams, belts and bearings;
small electrical components, such as capacitors
3
with a volume not exceeding 1 750 mm ,
integrated circuits, transistors and optocoupler
packages, if these components are mounted on
material of flammability category FV-1, or better,
according to AS/NZS 4695.707.
NOTE In considering how to minimize
propagation of fire and what small parts are,
account should be taken of the cumulative effect
of small parts adjacent to each other for the
possible effect of propagating fire from one part to
another.
Compliance shall be checked by the tests of
4.7.201.2, 4.7.201.3, 4.7.201.4 and 4.7.201.5.
For the base material of printed boards,
compliance shall be checked by the test of
4.7.201.5.
The tests shall be carried out on parts of nonmetallic material which have been removed from
the apparatus. When the glowwire test is carried
out, the parts shall be placed in the same
orientation as they would be in normal use. These
tests are not carried out on internal wiring.
Result Remark
Verdict
N/A
Page 53 of 95
TS09080083-ST
Requirement Test
Result Remark
4.7.201.2
Verdict
N/A
Replace with:
The duration of application
of the test flame shall be 30
s 1 s.
N/A
Page 54 of 95
TS09080083-ST
Requirement Test
(cont.)
8 Test procedure
8.2
8.4
Result Remark
N/A
Replace the first sentence
with:
The specimen shall be
arranged so that the flame
can be applied to a vertical
or horizontal edge as shown
in the examples of figure 1.
The first paragraph does not
apply.
Addition:
8.5
10 Evaluation of
test results
Replace with:
The duration of burning (tb)
shall not exceed 30 s.
However, for printed circuit
boards, it shall not exceed
15 s.
Verdict
Page 55 of 95
TS09080083-ST
Requirement Test
4.7.201.4
Result Remark
Verdict
N/A
Page 56 of 95
TS09080083-ST
Requirement Test
4.7.201.5
Result Remark
Verdict
N/A
Page 57 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
6.2.2
N/A
N/A
Page 58 of 95
TS09080083-ST
Requirement Test
Result Remark
6.2.2.2
Verdict
N/A
Page 59 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
National Condition
Page 60 of 95
TS09080083-ST
Requirement Test
1.1.1
1.4.14
1.5.5
Result Remark
Verdict
P
N/A
N/A
N/A
N/A
Page 61 of 95
TS09080083-ST
Requirement Test
2.7.1
Result Remark
Verdict
N/A
3.2.1
N/A
3.2.3
Permanent connection of equipment to the mains The EUT is not such equipment
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
N/A
3.2.5
N/A
N/A
N/A
3.2.9
3.3
N/A
3.3.3
N/A
3.3.4
N/A
3.4.2
N/A
Page 62 of 95
TS09080083-ST
Requirement Test
Result Remark
3.4.8
No such device
4.3.12
The maximum quantity of flammable liquid stored No such material within the
in equipment is required to comply with NFPA 30. EUT
N/A
4.3.13
N/A
4.7
N/A
4.7.3.1
N/A
Annex H
Verdict
N/A
N/A
OTHER DIFFERENCES
The following key national differences are based
on requirements other than national regulatory
requirements. The bi-national standard
(CAN/CSA-C22.2 No. 60950-1/UL 60950-1, First
Edition) referenced above should be consulted for
further details on the national differences
summarized below.
SubClause
National Difference
Page 63 of 95
TS09080083-ST
Requirement Test
1.5.1
Result Remark
Verdict
P
2.3.2
N/A
N/A
Page 64 of 95
TS09080083-ST
Requirement Test
2.6.3.3
3.2.1.2
N/A
4.2.8.1
Enclosures around CRTs with a face diameter of No such device within the EUT
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
N/A
4.3.2
N/A
5.1.8.3
N/A
6.2.1
N/A
6.4
N/A
6.5
N/A
M.2
N/A
Result Remark
Verdict
N/A
Page 65 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
1.4.5
1.7.1
N/A
N/A
N/A
N/A
replaced by:
Instructions and equipment marking related to
safety shall be written in simplified Chinese in
which the equipment is to be installed.
3.2.1
Page 66 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
1.2
Addition:
N/A
1.2.4.101
Equipment, Class 0I
1.2.4.101
Material, VTM
1.2.12.101
Addition:
CLASS 0I EQUIPMENT: equipment where
protection against electric shock is achieved by:
a using BASIC INSULATION, and
b providing a means of connecting to the
protective earthing conductor in the building
wiring those conductive parts that are
otherwise capable of assuming
HAZARDOUS VOLTAGES is the BASIC
INSULATION fails, and
c using a supply cord without earthing
conductor and plug without earthing wire
although the equipment has externally an
earth terminal or a lead wire for earthing.
Equipment provided with a cord set having a twopin type plug with a lead wire for earthing is also
regarded as Class 0I.
NOTE Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation as well as an operating part as SELV
circuit.
N/A
Page 67 of 95
TS09080083-ST
Requirement Test
1.2.12.1
Replacement:
Result Remark
Verdict
P
FLAMMABILITY CLASSIFICATION OF
MATERIALS: The recognition of the burning
behaviour of materials and their ability to
extinguish if ignited. Materials are classified as in
1.2.12.2 to 1.2.12.9, and 1.2.12.101 when tested
in accordance with annex A.
NOTE 1 When applying the requirements in this
standard, HF-1 CLASS FOAMED MATERIALS
are regarded as better than those of CLASS HF2, and HF-2 better than HBF.
NOTE 2 Similarly, other MATERIALS, including
rigidengineering structuralfoam of
CLASSSES 5V or V-0 are regarded as better
than those of CLASS V-1, V-1 better than V-2,
and V-2 better than HB.
NOTE 3 Similarly, for thin MATERIALS, VTM-0
Class materials are regarded as better than those
of VTM-1 Class, and VTM-1 better than VTM-2.
1.2.12.101 Addition:
N/A
Addition:
Marking for CLASS 0I EQUIPMENT
For CLASS 0I EQUIPMENT, the following
instruction shall be indicated on the visible place
of the mains plug or the main body:
Provide an earthing connection
Moreover, for CLASS 0I EQUIPMENT, the
following instruction shall be indicated on the
visible place of the main body or written in the
operating instructions:
Provide an earthing connection before the mains
plug is connected to the mains. And, when
disconnecting the earthing connection, be sure to
disconnect after pulling out the mains plug from
the mains.
N/A
Page 68 of 95
TS09080083-ST
Requirement Test
2.1.1.1
Replacement:
Result Remark
Verdict
N/A
Addition:
N/A
st
Replacement:
Replace 2
nd
N/A
st
sentence in 1 paragraph.
Replacement:
N/A
st
Replace 1 sentence.
Protective earthing connections of CLASS I
EQUIPMENT shall make earlier and break later
than the supply connections in each of the
following.
2.6.101
Addition:
N/A
N/A
4.2.8
Addition:
N/A
Page 69 of 95
TS09080083-ST
Requirement Test
4.5.1
Addition:
Result Remark
Verdict
P
Addition:
N/A
th
Page 70 of 95
TS09080083-ST
Requirement Test
5.1.6
Replacement:
Replace Table 5A.
Type of
equipment
Result Remark
Verdict
N/A
Terminal A of Maximum
Maximum
measuring
TOUCH PROTECTIVE
instrument CURRENT CONDUCTOR
connected to: mA r.m.s.1)
CURRENT
0,25
0,75
3,5
3,5
3,5
5 % of input
current
0,5
1,0
1)
5.3.8.2
Replacement:
rd
N/A
Page 71 of 95
TS09080083-ST
Requirement Test
Annex A
Addition:
Result Remark
Verdict
N/A
Addition:
N/A
Addition:
N/A
Replacement:
Replace 2
nd
N/A
paragraph.
Replacement:
Electric strength
The test sample is prepared according to IEC
60851-5:1997, 4.4.1 (for a twisted pair). The
sample is then subjected to the test of 5.2.2 of
this standard, with a test voltage not less than
twice the appropriate voltage in table 5B (see
5.2.2) of this standard. However, the minimum
values shall be as follows:
-
N/A
Page 72 of 95
TS09080083-ST
Requirement Test
U.2.2
Replacement:
Result Remark
Verdict
N/A
Table U.1
Replacement:
N/A
Mandrel diameter
1)
Mandrel diameter
mm
mm 0.2mm
0,05-0,34
4,0
0,35-0,49
6,0
0,50-0,74
8,0
0,75-2,49
10,0
2,50-5,00
Page 73 of 95
TS09080083-ST
Requirement Test
U.2.3
Replacement:
Result Remark
Verdict
N/A
Replacement:
N/A
Replacement:
Replace with the following.
The test voltage for ROUTINE TESTING shall be
the appropriate voltage in table 5B (see 5.2.2) of
this standard. However, the minimum values shall
be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V r.m.s.
or 4200 V peak.
N/A
Page 74 of 95
TS09080083-ST
Requirement Test
U.3.2
Replacement:
Replace with the following.
Twisted pair samples shall be tested in
accordance with IEC 60851-5:1996, 4.4.1. The
minimum breakdown voltage shall not be less
than twice the appropriate voltage in table 5B
(see 5.2.2) of this standard. However, the
minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V r.m.s. or 4200 V peak, or;
- for REINFORCED INSULATION, 6000 V r.m.s.
or 8400 V peak.
Result Remark
Verdict
N/A
Page 75 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
1.5.101
Addition
Plugs for the connection of the apparatus to the
supply mains shall comply with the Korean
requirement (KSC 8305 and 8305).
Addition
EMC
The apparatus shall comply with the relevant
CISPR standards.
N/A
N/A
Page 76 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
National Condition
1.1.1
1.4.14
N/A
Page 77 of 95
TS09080083-ST
Requirement Test
1.5.5
Result Remark
Verdict
N/A
N/A
N/A
2.7.1
N/A
3.2.1
N/A
N/A
Page 78 of 95
TS09080083-ST
Requirement Test
3.2.3
Permanent connection of equipment to the mains The EUT is not such equipment
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
N/A
3.2.5
N/A
N/A
Result Remark
Verdict
3.2.9
3.3
N/A
3.3.3
N/A
3.3.4
N/A
3.4.2
N/A
3.4.8
N/A
3.4.11
N/A
4.3.12
The maximum quantity of flammable liquid stored No such material within the
in equipment is required to comply with NFPA 30. EUT
N/A
4.3.13
N/A
No such device
Page 79 of 95
TS09080083-ST
Requirement Test
Result Remark
4.7
N/A
4.7.3.1
N/A
Annex H
Verdict
N/A
OTHER DIFFERENCES
The following key national differences are based
on requirements other than national regulatory
requirements.
SubClause
National Difference
Page 80 of 95
TS09080083-ST
Requirement Test
1.5.1
Result Remark
Verdict
P
2.3.2
N/A
2.6.3.4
N/A
3.2.1.2
N/A
N/A
Page 81 of 95
TS09080083-ST
Requirement Test
4.2.8.1
Enclosures around CRTs with a face diameter of No such device within the EUT
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
N/A
4.3.2
N/A
5.1.8.3
N/A
6.2.1
N/A
6.4
N/A
6.5
N/A
M.2
Result Remark
Verdict
N/A
Page 82 of 95
TS09080083-ST
Requirement Test
Result Remark
Verdict
National Differences
Argentina (AR), China (CN), Israel (IL), India (IN), Japan (JP), Kenya (KE),
Malaysia (MY) and Singapore (SG)
IEC 60950-1, 1st ed.
No national differences.
Page 83 of 95
TS09080083-ST
Requirement Test
Result Remark
1.5.1
Verdict
P
object/part
No.
manufacturer/
trademark
type/model
technical data
standard
mark(s) of
1)
conformity
External
power supply
(optional)
Phihong
PSC05R-050
IEC 60950-1:
2001
CB / TV/Rh
IEC 60950-1:
2001
CB / TV/Rh
CB / TV/Rh
O/P: 5 Vdc, 1 A,
complies with LPS
Alt.
Phihong
PSC05R-050
PH
Alt.
Phihong
PSAA05X-050
(X = A, C, E, K
or S)
O/P: 5 Vdc, 1 A,
complies with LPS
Alt.
Phihong
CB / TV/Rh
O/P: 5 Vdc, 1 A
max., complies
with LPS
Alt.
Alt.
Phihong
Delta
PSAI05X050YYY (X =
A, C, E, K, S,
H; Y = 0-9, A-Z
or blank)
ADP-5FH X (X
= A, B, C, D or
E)
CB / TV/Rh
O/P: 5 Vdc, 1 A
max., complies
with LPS
IEC 60950-1:
2001
CB / TV/Rh
IEC 60950-1:
2001
CB / TV/Rh
O/P: 5 Vdc, 1 A,
complies with LPS
Alt.
Delta
EADP-5GB X
(X can be A, B,
C, D)
Page 84 of 95
TS09080083-ST
Requirement Test
Result Remark
1.5.1
Verdict
P
object/part
No.
manufacturer/
trademark
type/model
technical data
standard
mark(s) of
1)
conformity
Alt.
Delta
EADP-5GB E
IEC 60950-1:
2001
CB / TV/Rh
IEC 60950-1:
2001
CB / TV/Rh
IEC 60950-1:
2001
CB / TV/Rh
O/P: 5 Vdc, 1 A,
complies with LPS
Alt.
Delta
EADP-5LB A
Alt.
HTC
TC P300
Alt.
Tamura
CB / TV/Rh
LCD panel
Sharp
LQ043Y1DX01
Applicable parts
of IEC 60950-1
Tested in
appliance
Alt.
AUO
H430VL01
Applicable parts
of IEC 60950-1
Tested in
appliance
Alt.
various
various
Applicable parts
of IEC 60950-1
Tested in
appliance
Speaker
various
various
8 , max. 1.5 W
Applicable parts
of IEC 60950-1
Tested in
appliance
Page 85 of 95
TS09080083-ST
Requirement Test
Result Remark
1.5.1
Verdict
P
object/part
No.
manufacturer/
trademark
type/model
technical data
standard
mark(s) of
1)
conformity
Vibrator
JINLONG
MACHINERY
&
ELECTRONIC
S CO., LTD.
Z4TJGB15124
03
Applicable parts
of IEC 60950-1
Tested in
appliance
Car adapter
(optional)
Phihong
CLM10D-050
CB / TV/Rh
O/P: 5 Vdc, 2 A or
5.15 Vdc, 2 A,
complies with LPS
Alt.
Alt.
Battery pack
Hwa Ying
Industrial Co.,
Ltd.
AP-03
IEC 60950-1:
2001
CB / Intertek
L&K Precision
Technology
Co., Ltd.
G12PCL-*** (*
= 0-9, A-Z or
blank)
IEC 60950-1:
2001
CB / Intertek
Formosa
Electronic
Industries Inc.
(hTC
INNOVATION)
BB81100
Applicable parts
of IEC 60950-1,
UL 60950-1,
UL 2054
UL recognized
TMB7003+
O/P: 5 Vdc, 1 A,
complies with LPS
O/P: 5 Vdc, 1 A,
complies with LPS
Mitsubishi
Applicable parts
of IEC 60950-1,
UL 94
UL recognized
Alt.
Teijin
GV-35(cc)R (cc V-0, min. 0.75 mm
Chemicals Ltd. = 10-30)
thick, 80 C
Applicable parts
of IEC 60950-1,
UL 94
UL recognized
Alt.
Sabic
Innovative
Applicable parts
of IEC 60950-1,
UL 94
UL recognized
Alt.
Sabic
Innovative
Applicable parts
of IEC 60950-1,
UL 94
UL recognized
Applicable parts
of IEC 60950-1,
UL 94
UL recognized
Alt.
various
CX7240
C6200
various
Page 86 of 95
TS09080083-ST
Requirement Test
Result Remark
1.5.1
Verdict
P
object/part
No.
manufacturer/
trademark
type/model
technical data
standard
mark(s) of
1)
conformity
PCB
Unimicron
Technology
Corp.
2MV
V-0, 130 C
Applicable parts
of IEC 60950-1,
UL 94, UL 796
UL recognized
Alt.
various
various
Applicable parts
of IEC 60950-1,
UL 94, UL 796
UL recognized
All
connectors
various
various
Min. V-2
Applicable parts
of IEC 60950-1
Tested in
appliance
Note:
1) An asterisk indicates a mark which assures the agreed level of surveillance.
2) All the plastic material mentioned are checked and found to be acceptable for using in this product.
Checking date: Same as this report issued data, see also page 1.
Page 87 of 95
TS09080083-ST
Requirement Test
1.6.2
fuse Irated
#
(A)
Result Remark
U (Vdc)
P (W)
I (A)
Ifuse (A)
4.55
0.91
Verdict
condition/status
Maximum normal operation
with empty battery pack
charging
supplementary information
Note:
2.1.1.5
N/A
measured
between
max. V (Uoc)
max. A (Isc)
V of max.
power
A of max.
power
max. power
bridged by
test finger
supplementary information
Note:
2.1.1.7
test conditions:
N/A
calculated (s)
measured (s)
tu 0 (s)
comments
supplementary information
Note:
1) X-Capacitor(s) installed for testing:
2) Bleeding resistor(s):
2.2.2
supplementary information
Note:
Test voltage:
N/A
location
max. Voltage
Vpeak
Vdc
voltage limitation
component
Page 88 of 95
TS09080083-ST
Requirement Test
Result Remark
2.2.3
Verdict
N/A
location
comments
supplementary information
Note:
Test voltage:
2.4.2
N/A
location
voltage (V)
current (mA)
frequency
(kHz)
limit (mA)
Comments
supplementary information
Note:
1) Test voltage:
2) Rating of bridging components:
Page 89 of 95
TS09080083-ST
Requirement Test
Result Remark
2.5
8.0 A
(5 x Uoc)
8.0 A
(5 x Uoc)
Verdict
N/A
measured
verdict
Page 90 of 95
TS09080083-ST
Requirement Test
2.6.3.4
Result Remark
resistance measured
limit
Verdict
N/A
comments
(m)
100 m
100 m
location
limit
comments
(V)
2.5 V
supplementary information
Note:
2.10.2
Pri. Pins
Vrms
Vpeak
Vrms
Vpeak
N/A
Vrms
Vpeak
Vrms
Vpeak
Vrms
Vpeak
Sec. pins
Note:
1) Test voltage:
2) Bold texts indicate the highest Vrms and Vpeak
N/A
Up
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required
dcr (mm)
dcr
(mm)
supplementary information
Note:
1) FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.
Page 91 of 95
TS09080083-ST
Requirement Test
2.10.5
Result Remark
Verdict
N/A
Up
(V)
test voltage
(V)
required di
(mm)
di
(mm)
Up
(V)
test voltage
(V)
required
layer(s)
layer(s)
supplementary information
Note:
1) FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.
Page 92 of 95
TS09080083-ST
Requirement Test
Result Remark
4.5
Verdict
P
5 Vdc
Supplied
by battery
pack
25
25
25
25
T (C)
57.0
49.4
80 (105-25)
56.8
48.0
80 (105-25)
Charge IC body(PAU1)
64.8
48.6
80 (105-25)
63.7
48.3
80 (105-25)
37.7
38.1
47.5
42.0
50 (75-25)
46.2
42.7
50 (75-25)
temperature T of winding:
R1 ()
R2 ()
T (C)
allowed
Tmax (C)
insulation
class
supplementary information
Note:
Maximum room ambient temperature:
The equipment was submitted and evaluated for maximum manufacturers recommended ambient (Tmra) of
50 C.
Page 93 of 95
TS09080083-ST
Requirement Test
4.6.1,
4.6.2
location
Result Remark
Verdict
N/A
size (mm)
comments
supplementary information
Note:
4.6.4
location
size (mm)
P
comments
Front
Rear
supplementary information
Note:
Page 94 of 95
TS09080083-ST
Requirement Test
4.7
Result Remark
Verdict
P
manufacturer of material
type of material
thickness
(mm)
flammability
class
Enclosure
Mitsubishi
MB1700+
Min. 0.81
V-0
Alt.
Mitsubishi
TMB7003+
Min. 0.75
V-0
Alt.
Min. 0.75
V-0
Alt.
Unitika
EN-RUNG50LWF
Min. 0.80
V-0
Alt.
Sabic Innovative
CX7240
Min. 0.75
V-0
Alt.
Sabic Innovative
C6200
Min. 1.5
V-0
Alt.
various
various
Min. 0.75
Min. HB
PCB
2MV
Min. 1.0
V-0
Alt.
various
various
Min. 1.0
Min. V-1
supplementary information
Note:
5.1
N/A
limit (mA)
comments
supplementary information
Note:
5.2
TABLE: electric strength tests, impulse tests and voltage surge tests
supplementary information
Note:
N/A
breakdown
Yes / No
Page 95 of 95
TS09080083-ST
Requirement Test
5.3
No.
component
No.
Result Remark
fault
test voltage
(Vdc)
test
time
fuse
No.
input
current
(A)
Verdict
result
For EUT:
1.
PAU1 pin
1-20
7 hours
2.
PAC2
(during
battery
pack
discharge
mode)
7 hours
Vibrator
7 hours
Observation: Temperature
stabilized. No hazards.
Damaged:
Temp: Vibrator body = 36.2 C max.
Max. Voltage:
supplementary information
Note:
1) S: Short-circuited; O: Open-circuited; O/L: Overloaded; B: Blocked; L: Locked.
2) Observation: The observations during and after fault condition tests.
3) Damaged: Which component (components) damaged during the fault condition test.
4) Temp: The maximum temperature of relevant components.
5) Max. Voltage: The maximum accessible voltage of DC output terminal during the fault condition test.
6) All fault condition tests were simulated when the battery pack charging.
Photos
Page 1 of 3
TS09080083-ST
Photos
Page 2 of 3
TS09080083-ST
Photos
Page 3 of 3
Battery Pack (Representative)