CONCRETE-TOP
SUPREME
ONE PART, MODIFIED
DECK REPAIR
CONCRETE-TOP SUPREME is a latex and
microsilica modified cementitious mortar designed
for use as a concrete repair mortar at thicknesses
of 13 mm - 50 mm. This product is a one part
formula which incorporates dry latex technology.
It provides excellent durability under freeze-thaw
cycling as well as reducing ingress by water and
deicing salts. CONCRETE-TOP SUPREME offers
normal set times and a mid range slump for easy
workability.
PRIMARY APPLICATIONS
l Parking decks
l Docks
l Curbs and gutters
l Pavements & walkways
l Floors
l Marine structures
l Ramps
l Joints
FEATURES / BENEFITS
l Provides a strong, wear resistant topping
l Excellent durability under freeze/thaw
cycling
l Resists penetration of water and de-icing
salts for good substrate protection
l Excellent bond to properly prepared sound
concrete
l Easy to use one part system
l Suitable for both indoor and outdoor use
l High slump formula for easy handling
SPECIFICATIONS / COMPLIANCES
l CONCRETE-TOP SUPREME meets or
exceeds the bond strength requirements of
ASTM C-1059-86, Type II.
PACKAGING / YIELD
CONCRETE-TOP SUPREME is packaged in 25
kg bags. When mixed with 2.5 liter of water, yield
is 0.012 m3. A unit of material may be extended
with 6.8 kg of 9.5 mm pea gravel. This will yield
0.015 m2 and may be used for overlay placements
that exceed 50 mm in depth.
TECHNICAL INFORMATION
Typical Engineering Data
Compressive Strength
ASTM C-109, 50 mm cubes
Age
Strength
2 hours
750 psi (5.2 MPa)
1 day
2,500 psi (17.2 MPa)
3 days
3,500 psi (24.1 MPa)
7 days
5,500 psi (34.5 MPa)
28 days
6,500 psi (44.8 MPa)
Flexural Strength
ASTM C-78
1 day
700 psi (5.2 MPa)
3 days
800 psi (5.5 MPa)
28 days
1,200 psi (8.3 MPa)
Working Time
30 minutes
Initial Set
1 hour
Final Set
2 hours
Unit Weight
2168 kg/m3
Appearance
CONCRETE-TOP SUPREME is a free flowing
powder as packaged. After mixing and placing,
the color may initially appear darker than the
surrounding concrete. The color will lighten up
substantially as the CONCRETE-TOP SUPREME
cures.
This product is designed for finishing with a float
or broom. A steel trowel finish may be applied but
timing of the final trowel is critical.
DIRECTIONS FOR USE
Surface Preparation - New concrete must be a
minimum of 28 days old if an epoxy adhesive will
be used to bond the topping. If a slurry coat is
used, the concrete must be a minimum of 3 days
old.
The concrete must be clean and rough. All oil,
dirt, debris, paint and unsound concrete must be
removed. The surface must be prepared
mechanically using a scabbler, bushhammer,
shotblast or scarifier which will give a surface profile
of a minimum 3 mm and expose the large
aggregate of the concrete. The final step in cleaning
should be the complete removal of all residue
(pressure washing, etc.).
Joints and Edges - Edges should be sawcut to 6
mm deeper than the topping thickness and the
floor should be notched at the edge of the repair
to provide a locked in, reinforced edge. Moving
joints as in the case of expansion joints should be
brought up through the repair by sawcutting or with
the use of a divider strip.
PRECAUTIONS / LIMITATIONS
l Do not allow repairs to freeze until the
material has reached a minimum of 1000
psi (7 MPa) compressive strength
[approximately 48 hours @ 4C].
l In adverse temperatures, follow ACI
recommendations for hot/cold weather
concreting practices.
l Use only potable water for mixing.
l Do not use material at temperatures below
7C.
l No heavy traffic until the product has cured.
l Mixing partial bags may yield variable
results. Always mix full units.
CLEAN-UP
Clean tools and equipment with water before the
material hardens.