OPERATION
When energized, the SV12-21 acts as a check valve, allowing flow to pass from 1 to
2, while blocking flow in the reverse direction.
When de-energized, the poppet lifts to open the 2 to 1 flow path after overcoming the
solenoid force (requires 3.4 to 10.3 bar / 50 to 150 psi). In this mode, flow from
1 to 2 is severely restricted. If this path is required, see model SV12-23,
page 1.054.1.
Operation of Manual Override Option: To override, push and hold override button.
FEATURES
Continuous-duty rated solenoid.
Hardened seat for long life and low leakage.
Optional coil voltages and terminations.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Unitized, molded coil design.
Manual override option.
Optional waterproof E-Coils rated up to IP69K.
Cost effective cavity.
SYMBOLS
ISO:
with Sensor:
RATINGS
10.3/150
2 to 1 de-energized
1 to 2 energized - - - 32 cSt/150 sus oil at 40C
8.3/120
6.2/90
4.1/60
2.1/30
37.9
10
75.8
20
113.6
30
FLOW lpm/gpm
27.6/400
20.7/300
13.8/200
6.9/100
37.9
10
75.8
20
FLOW lpm/gpm
1.035.1
113.6
30
VOUT
Vcc
113.6 lpm
30 gpm
FLOW
0.4 lpm
0.1 gpm
0
50
68 73
100
VALVE SHIFT %
Hatched Area: Overlapping Stroke, Leakage Flow
HYDRAFORCE.com
HYDRAFORCE
SV12-21
DIMENSIONS
1.84 (46.7) DIA.
1.62
41.1
TORQUE
5-7 lbfft
(6.8-9.5 Nm)
2.89
73.4
Standard
Coil View
E-Coil
View
TORQUE
33-37 lbfft
(44.7-50.2 Nm)
Dimensions will differ significantly with Sensor Option; see page 3.010.1.
MATERIALS
TO ORDER
Sensor
SV12-(P)21(A)__ - __ __ __ - __ - __ __ __ __ __ - __
__Option: See page 3.010.1
HYDRAFORCE.com
Position
Indicator
None (Blank)
Switch P
Restricted Flow A
Option
None (Blank)
Manual Override P
Manual Override K
For Manual Override options
see page 1.001.1
Porting
Cartridge Only 0
SAE 12 12T
Sensor Type
(Blank) None
Voltage
Std. Coil
0 Less Coil**
10 10 VDC
12 12 VDC
24 24 VDC
36 36 VDC
48 48 VDC
24 24 VAC
115 115 VAC
230 230 VAC
**Includes Coil Nut
DS, DW or DL
terminations only
E-Coils: 10,12,20
or 24 VDC only.
Seals
N Buna N (Std.)
V Fluorocarbon
Dual Output,
N.C./N.O.
Sensor/Connector
(Blank) None
N
M
Neutral Sense/DT04-4P
Neutral Sense/M12-4P
Mating Connectors:
DT06-4S: Part No. 4001953
M12-4S: available at www.turck.com
or www.binder-usa.com
Coil Termination
Deutsch DT04-2P
Metri-Pack 150
Dual Lead Wires
Amp Jr. Timer
DIN 43650
Dual Spades
E-Coil
D-Coil
ER (IP69K) DR (IP65)
EY (IP69K) DY (IP65)
EL (IP69K) DL (IP65)
EJ (IP67)
EG (IP65) DG (IP65)
DS (IP65)
1.035.2