Sunteți pe pagina 1din 16

Product

Data

42WKN
Hydronic Fan
Coil Units
3/

UNIT SIZES 004-010

to 21/2 Tons

The Carrier Hydronic Cassette offers


a modern solution for a wide variety of
small and medium sized residential
and commercial applications.
The 42WKN unit is installed in suspended ceilings and offers two, three,
or four-way air diffusion. The units
maintain precise temperature and humidity conditions to prevent drafts and
stale air.
The 42WKN unit is available in five
sizes with capacities ranging from 3/4
to 21/2 tons. Sizes 010 and 020 are
available with a hot water coil for fourpipe systems upon request. Because
of the high heat transfer efficiency of
the coil, the 42WKN unit may be used
with water source heat pumps or heat
recovery systems. The 42WKN unit
can be supplied from a chiller, a water
source heat pump, or a boiler (maximum entering water temperature at
180 F). The 42WKN unit may also be
used with cabinet-type fan coil units
installed along perimeter walls.

Features/Benefits
Technology and components
The high-efficiency one, two, or threerow heat exchanger has mechanically
expanded copper tubes with continuous aluminum fins. The coil connections are made of brass. The upper coil
has an air purge port, and the lower
coil has a drainage port.

Fan motor
UNIT SIZES 016,020

Copyright 2005 Carrier Corporation

The direct-drive fan with backward


curved blades has a three-speed permanent split capacitor motor with
built-in thermal protection, regulated
by an electronic thermostat. It is installed on spring anti-vibration mounts.
This fan blade design ensures uniform
airflow through the heat exchanger.
Form 42WKN-1PD

Diffusers
Four-way air distribution gives individual comfort. For localized control,
each diffuser may be adjusted or
even shut down completely. The special design of the diffusers ensure
rapid blending of the supply and
room air. Conditioned air is directed
along the ceiling, then evenly distributed throughout the room. Return air
enters the cassette unit through a
large grille. It is then cleaned by an
easily removable, washable synthetic
filter.

Controls
Three different thermostats are available, suitable for installation on a
wall. The solid-state electronic thermostat is available in programmable
flat stat, Slimline Stat and a 5-1-1
programmable style.

Table of contents
Page
Features/Benefits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,2
Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ARI Capacity Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Physical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,5
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Typical Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Typical Wiring Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Model number nomenclature


42 SERIES HYDRONIC CASSETTE FAN COILS
42WKN

008

Accessories
A two-position, motorized three-way
valve accessory package is available.
The package includes the preassembled tubing, valve, fittings, and valve
condensate drip pan.
A power vent accessory is also available for introduction of outside fresh
air, when required.

Minimum installation
clearance
The unit is designed to fit standard
ceiling tiles. Its low-profile size
(115/8 in.) makes it ideal for building
refurbishment projects where ceiling
heights are limited. The diffuser only
protrudes 1 inch into the room.

42WKN In-Ceiling Cassette

Voltage Designation
3 208/230-1-60

Nominal Cooling Capacity (Btuh)


004 7,000
008 13,000
010 14,000
016 27,000
020 32,000

Pipe Version
T Two Pipe
F Four Pipe*

*Available on sizes 010 and 02 only.

ARI* capacity ratings


42WKN
UNIT SIZE

PIPE
VERSION

STANDARD
CFM

004
008

2
2
2
4
2
2
4

420
420
400
440
840
920
975

010
016
020

TOTAL NET
COOLING
(Btuh)
6,900
13,200
13,700
13,280
27,000
31,600
28,800

SENSIBLE
COOLING
(Btuh)
6,100
10,100
9,600
9,800
20,600
22,500
21,600

HEATING
(Btuh)
13,600
23,000
20,700
11,600
46,800
51,500
25,200

GALLONS
PER MINUTE
(GPM)
1.4
2.7
2.9
2.9
5.4
6.8
6.4

PRESSURE
DROP
(in. wg)
1.3
3.1
6.0
4.3
3.2
5.4
4.1

*Air Conditioning and Refrigeration Institute.


NOTE: Systems are rated and certified in accordance with ARI Standard 440.

Physical data
UNIT 42WKN
PIPE VERSION
OPERATING WEIGHT (lb)
MAXIMUM ENTERING WATER TEMP (F)
FAN (qty)
Rpm
High
Med
Low
NOMINAL CFM
High
Med
Low
COIL
Rows
Cooling
Heating
Face Area (sq ft)
Cooling
Heating
No. of Circuits
Cooling
Heating
CONNECTIONS
2-Pipe Valve Tubing Connections (in.)
4-Pipe Valve Tubing Connections (in.)
Condensate Drain, Barbed (in.)

004
2
57.8

008
2
60.0

2
64.4

1
755
540
350

1
755
550
360

1
1015
730
650

4
65.6
180
1
1015
730
650

420
320
280

420
320
280

390
300
280

2.7

2
2

2.7

3
3

2.5

4
4

1/
2

1/
2

1/
2

010

016
2
108.9

2
115.6

4
117.8

2
755
550
360

2
1140
880
785

2
1140
880
785

420
300
280

840
600
560

920
740
675

975
740
675

3
1
2.5
2.5
4
1

5.4

3
3

5.2

4
4

3
1
5.2
5.6
4
1

3/
4

3/
4

1/
2

020

1/
2

NOTE: Two-pipe units use same coil for both heating and cooling operations.

Dimensions 42WKN004-010
*HOT WATER COIL
INLET 1/2"
1.8 (45)

38.17 (969)
25.2 (640) +.6 (15)
22.4 (570)
6.6 (168)
3.6 (92)
1.8
1.6 (40)
(45)

6.3
(160) 2.4
(60)
11.6
(295)

WATER INLET
CONNECTION 3/4"
(CHILLED OR HOT )

5.0
(126)

4.8 (121)

1.0 (25)
WATER OUTLET
CONNECTION 3/4"
(CHILLED OR HOT )

*HOT WATER COIL


OUTLET 1/2"

28 (711)

4.0
(101)
COIL
28.0
(711)
1.46 (370)
+0.6 (146)

FAN

4.0
(101)

13.8
(350)

HOSE
CONNECTION

2.0
(50)

1.0
O (25)

9.1
(230)

ELECTRIC PANEL
(REMOVABLE)
0.6 (15)

12.6
(320)

CONDENSATE
DRAIN
VALVE ASSEMBLY AND
CONDENSATE PAN
OVERALL DIMENSIONS

4.7
O (120)

ADJACENT AIR DUCT


(PREPUNCHED)

*Four-pipe version only.


NOTE: Dimensions are in inches (mm).

5.51
(140)
9.1
O (230)
7.9
(200)

11.2
(280)

4.7
O (120)

FRESH AIR INLET


(PREPUNCHED)
3.5
(90)

UNIT SIZE
42WKN
004
008
010

NET WEIGHT (lb)


2-Pipe Version
4-Pipe Version
57.8

60.0

64.4
65.6

Dimensions 42WKN016,020

6.3
(160)
11.6
(295)

51.0 (1296)
48.8 (1240) +- 0.6 (15)
46.1 (1170)
3.0 (75)
4.8 (123)
1.6 (40)
1.8 (45)
2.4 (60)
4.8 (123)
5.0 (126)

1.0 (25)
*HOT WATER
20.0 COIL INLET 1/2"
(510) *HOT WATER
COIL OUTLET
1/2"

WATER OUTLET
CONNECTION 1"
(CHILLED OR HOT)

23.6
(600)

WATER INLET
CONNECTION 1"
(CHILLED OR HOT)

49.6 (1260)

COIL

4.0
(101)

COIL

14.6 (370)
+
- 0.6 (15)

FAN

FAN

28.0 (711)

4.0
(101)

17.3
(440)

O 1.0 (25)

12.6 (320)
CONDENSATE
DRAIN

10.2 (260)
12.6 (320)

0.6 (15)
ELECTRIC
PANEL

VALVE ASSEMBLY AND


CONDENSATE DRAIN PAN
OVERALL DIMENSIONS
2.4 (60)

4 HOLES

5.51 (140)

4.72 (120)

ADJACENT AIR DUCT


(PREPUNCHED)

*Four-pipe version only.


NOTE: Dimensions are in inches (mm).

14.6 (370)

O 4.72
(120)

O 9.1
(230)

O 9.1
(230)
16.93 (430)

11.02 (280)

UNIT SIZE
42WKN
016
020

FRESH AIR INLET


(PREPUNCHED)
3.5 (90)

NET WEIGHT (lb)


2-Pipe Version
4-Pipe Version
108.9

115.6
117.8

Selection procedure
I Determine job requirements.
Given:
Room Sensible Cooling Load . . . . . . .10,000 Btuh
Room Total Cooling Load . . . . . . . . .13,000 Btuh
Entering-Air Temperature . . . . . 67 F wb, 80 F db
Entering Water Temperature . . . . . . . . . . . . .45 F
Temperature Rise . . . . . . . . . . . . . . . . . . . . .10 F
External Static Pressure . . . . . . . . . . . . . . 0 in. wg
Nominal Air Delivery . . . . . . . . . . . . . . . . 400 cfm
II II Determine unit size and nominal cfm.
For an initial selection, choose a unit size that will
provide the required airflow (cfm). Refer to the ARI
Capacities table on page 3. Enter the Physical Data
table on page 3. At high speed, a 42WKN008 unit
will provide 420 cfm.
III III Determine cooling capacity.
Enter cooling capacity table for 42WKN008 on
page 7. Locate required entering dry bulb (edb) and

entering wet bulb (ewb) conditions. Locate the entering water temperature required. Under Total Heat
(TH) column, a 42WKN008 unit at an entering-air
temperature of 67 F wb and 80 F dry bulb, an entering water temperature of 45 F, and a water temperature rise of 10 F, will provide 13,282 Btuh.
IV IV Determine sensible heat.
In cooling capacity table for 42WKN008, locate the
sensible heat (SH) column and find that the
42WKN008 at the required conditions will provide
10,174 Btuh of sensible heat at a water temperature rise of 10 F. The 42WKN008 will satisfy the
job requirements.
If additional SH were required, a larger unit or a
lower entering water temperature would be needed.

Performance data
COOLING CAPACITIES
42WKN004
Entering Air (F) Dry Bulb
Entering
Water
Temp (F)

40
45

55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

72

80
Entering Air (F) Wet Bulb
63
67
71
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
6,807
5,160
9,525
4,848
12,370
4,379
7,520
7,452
9,514
7,164
12,364
6,788
4,091
3,882
6,306
3,613
9,348
3,319
6,099
6,099
6,532
5,938
9,336
5,667
2,585
2,285
2,850
2,337
5,729
2,080
4,703
4,703
4,697
4,688
5,712
4,408
4,381
4,092
6,882
3,826
9,728
3,453
6,273
6,273
6,889
6,133
9,712
5,800
2,754
2,754
3,318
2,552
6,384
2,298
4,905
4,905
4,918
4,884
6,368
4,623
1,726
1,726
1,753
1,646
2,469
1,035
3,498
3,498
3,504
3,504
3,623
3,427
1,659
1,659
1,657
1,649
3,633
1,399
3,810
3,810
3,818
3,818
4,062
3,733
731
731
732
732
813
508
2,416
2,416
2,421
2,421
2,426
2,426

1,398
1,398
1,400
1,400
1,401
1,401

42WKN004 (cont)
Entering
Water
Temp (F)

40

45
55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

Entering Air (F) Dry Bulb


88
Entering Air (F) Wet Bulb
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
9,514
9,514
9,777
9,445
12,356
9,119
8,196
8,196
8,212
8,212
9,324
7,981
6,838
6,338
6,851
6,851
7,009
6,778
8,328
8,328
8,344
8,344
9,704
8,113
7,014
7,014
7,028
7,028
7,224
6,949
5,665
5,665
5,676
5,676
5,688
5,688
5,908
5,908
5,920
5,920
5,933
5,933
4,588
4,588
4,597
4,597
4,607
4,607
3,211
3,211
3,217
3,217
3,224
3,224

LEGEND
SH Sensible Heat
TH Total Heat
42WKN008
Entering Air (F) Dry Bulb
Entering
Water
Temp (F)

40

45
55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

72

80
Entering Air (F) Wet Bulb
63
67
71
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
13,097
8,854
17,553
8,583
22,397
8,153
13,524
12,266
17,525
11,935
22,373
11,656
8,931
7,064
13,436
6,893
18,497
6,640
11,071
10,706
13,544
10,280
18,472
10,086
5,756
5,336
8,286
4,938
13,658
4,862
9,049
9,004
9,840
8,610
13,632
8,261
8,837
7,043
13,266
6,819
18,065
6,467
10,760
10,588
13,282
10,174
18,024
9,905
5,721
5,372
8,445
4,991
13,696
4,876
8,915
8,915
9,682
8,588
13,672
8,272
3,493
3,483
3,802
3,114
8,011
2,932
7,041
7,041
7,191
6,925
8,636
6,451
3,359
3,359
3,688
3,153
8,107
2,951
6,734
6,734
6,768
6,741
8,348
6,370
1,495
1,495
1,499
1,486
1,848
965
4,789
4,879
4,894
4,894
5,075
4,740

2,825
2,285
2,831
2,831
2,837
2,837

42WKN008 (cont)
Entering
Water
Temp (F)

40

45

55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

Entering Air (F) Dry Bulb


88
Entering Air (F) Wet Bulb
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
15,714
15,698
17,708
15,300
22,344
15,015
14,099
14,099
14,820
13,842
18,467
13,443
12,366
12,366
12,588
12,261
14,352
11,783
13,808
13,808
14,350
13,661
18,011
13,256
12,193
12,193
12,327
12,154
14,183
11,729
7,041
7,041
10,473
10,463
11,025
10,165
9,980
9,980
10,011
10,011
10,300
9,919
8,289
8,289
8,314
8,314
8,362
8,320
6,434
6,434
6,453
6,453
6,474
6,474

LEGEND
SH Sensible Heat
TH Total Heat

Performance data (cont)


COOLING CAPACITIES (cont)
42WKN010 2-PIPE
Entering Air (F) Dry Bulb
Entering
Water
Temp (F)

40
45

55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

72

80
Entering Air (F) Wet Bulb
63
67
71
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
13,056
8,513
17,563
8,483
22,296
8,316
13,497
11,648
17,539
11,488
22,270
11,402
8,995
6,746
13,436
6,745
18,508
6,755
10,946
10,245
13,629
9,813
18,485
9,816
5,780
5,133
8,264
4,735
13,681
4,898
8,884
8,724
9,856
8,220
13,705
7,963
8,903
6,713
13,340
6,697
18,160
6,592
10,538
10,095
13,406
9,719
18,132
9,646
5,713
5,153
8,491
4,814
13,755
4,924
8,707
8,655
9,729
8,182
13,742
7,957
3,799
3,712
4,184
3,134
7,961
2,882
6,902
6,902
7,136
6,672
8,738
6,143
3,302
3,302
3,715
3,013
8,194
2,950
6,551
6,551
6,629
6,516
8,490
6,062
1,669
1,669
1,679
1,619
2,177
1,028
4,796
4,796
4,812
4,812
5,099
4,553

3,109
3,109
3,116
3,116
3,134
3,062

42WKN010 2-PIPE (cont)


Entering
Water
Temp (F)

40

45
55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

Entering Air (F) Dry bulb


88
Entering Air (F) Wet bulb
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
15,165
14,968
17,733
14,541
22,238
14,410
13,608
13,581
14,780
13,154
18,543
12,850
12,024
12,024
12,435
11,751
14,522
11,210
13,253
13,253
14,289
12,960
18,121
12,667
11,799
11,799
12,098
11,638
14,319
11,140
10,187
10,187
10,252
10,180
11,099
9,701
9,621
9,621
9,657
9,657
10,231
9,433
8,089
8,089
8,118
8,118
8,220
8,064
6,322
6,322
6,344
6,344
6,367
6,367

LEGEND
SH Sensible Heat
TH Total Heat
42WKN010 4-PIPE
Entering Air (F) Dry Bulb
Entering
Water
Temp (F)

40
45

55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

72

80
Entering Air (F) Wet Bulb
63
67
71
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
11,439
7,721
15,681
7,652
20,104
7,418
12,139
10,779
15,658
10,569
20,081
10,422
7,528
5,992
11,331
5,869
16,053
5,811
9,738
9,280
11,705
8,861
16,032
8,770
4,887
4,486
6,209
3,912
11,069
3,963
7,713
7,682
8,424
7,287
11,144
6,920
7,712
6,092
11,665
5,996
16,216
5,854
9,585
9,288
11,802
8,922
16,193
8,825
4,784
4,497
6,734
4,114
11,575
4,132
7,745
7,737
8,510
7,395
11,560
7,075
3,299
3,279
3,602
2,770
5,717
2,132
5,915
5,915
5,988
5,832
7,080
5,367
2,821
2,821
3,085
2,628
6,789
2,478
5,909
5,909
5,943
5,907
7,308
5,518
1,435
1,435
1,437
1,433
1,805
893
4,102
4,102
4,114
414
4,238
3,984

2,696
2,696
2,701
2,701
2,707
2,707

42WKN010 4-PIPE (cont)


Entering
Water
Temp (F)

40

45
55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

LEGEND
SH Sensible Heat
TH Total Heat

Entering Air (F) Dry Bulb


88
Entering Air (F) Wet Bulb
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
14,010
13,898
16,011
13,529
20,054
13,336
12,396
12,396
13,259
12,079
16,151
11,709
10,743
10,743
10,965
10,592
12,477
10,144
12,257
12,257
13,020
12,057
16,174
11,726
10,710
10,710
10,876
10,626
12,531
10,200
9,036
9,036
9,062
9,062
9,664
8,707
8,833
8,833
8,863
8,863
9,282
8,706
7,230
7,230
7,253
7,253
7,296
7,252
5,425
5,425
5,441
5,441
5,460
5,460

COOLING CAPACITIES (cont)


42WKN016
Entering Air (F) Dry Bulb
Entering
Water
Temp (F)

40
45

55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

72

80
Entering Air (F) Wet Bulb
63
67
71
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
26,652
17,990
35,692
17,453
25,524
16,571
27,498
24,913
35,634
24,231
45,476
30,474
18,250
14,381
27,410
14,061
37,654
13,518
22,536
21,770
27,620
20,908
37,604
27,378
11,790
10,894
17,016
10,090
27,920
9,940
18,442
18,331
20,094
17,522
27,872
23,966
18,014
14,321
26,990
13,873
36,734
13,151
21,878
21,528
27,018
20,669
36,686
26,919
11,684
10,948
17,920
10,184
27,942
9,947
18,146
18,146
19,724
17,456
27,892
23,849
7,120
7,099
7,798
6,363
16,468
6,011
14,366
14,366
14,682
14,124
17,698
20,685
6,852
6,852
7,544
6,420
16,556
6,026
13,698
13,698
13,770
13,715
17,028
20,061
3,032
3,032
3,042
3,015
3,750
1,958
9,952
9,952
9,982
9,982
10,366
16,935

5,742
5,742
5,754
5,754
5,766
13,204

42WKN016 (cont)
Entering
Water
Temp (F)

40

45
55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

Entering Air (F) Dry Bulb


88
Entering Air (F) Wet Bulb
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
31,916
31,884
36,000
31,104
45,416
30,474
28,664
28,664
30,166
28,115
37,590
27,378
25,166
25,166
24,932
24,932
23,966
23,966
28,046
28,046
29,160
27,731
36,624
26,919
24,792
24,792
25,076
24,725
28,908
23,849
21,260
21,260
21,326
21,305
22,484
20,685
20,278
20,278
20,340
20,340
20,936
20,061
16,868
16,868
16,920
16,920
17,020
16,935
13,122
13,122
13,162
13,162
13,204
13,204

LEGEND
SH Sensible Heat
TH Total Heat
42WKN020 2-PIPE
Entering Air (F) Dry Bulb
Entering
Water
Temp (F)

40
45

55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

72

80
Entering Air (F) Wet Bulb
63
67
71
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
27,298
17,744
36,590
17,673
46,402
17,354
28,158
24,216
36,540
23,897
46,346
23,729
18,986
14,145
28,240
14,148
38,744
14,142
22,896
21,362
28,602
20,508
38,696
20,509
12,208
10,767
17,680
10,025
28,920
10,382
18,646
18,254
20,816
17,194
28,958
16,709
18,676
14,007
27,896
13,976
37,834
13,772
21,966
20,999
28,016
20,256
37,776
20,097
12,062
10,795
18,010
10,140
28,914
10,351
18,190
18,063
20,424
17,074
28,886
16,667
7,876
7,695
8,680
6,501
17,104
6,192
14,506
14,506
15,056
13,987
18,614
12,899
6,942
6,942
7,872
6,313
17,262
6,214
13,664
13,664
13,840
13,577
17,836
12,646
3,460
3,460
3,480
3,355
4,512
2,130
10,082
10,082
10,116
10,116
10,772
9,544

6,444
6,444
6,458
6,458
6,496
6,347

42WKN020 2-PIPE (cont)


Entering
Water
Temp (F)

40

45
55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

Entering Air (F) Dry Bulb


88
Entering Air (F) Wet Bulb
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
31,530
31,089
36,916
30,234
46,282
29,944
28,348
28,291
30,874
27,385
38,798
26,771
25,114
25,114
26,032
24,522
30,538
23,423
27,552
27,552
29,754
26,927
37,744
26,308
24,588
24,588
25,254
24,244
30,004
23,221
21,306
21,306
21,446
21,253
23,318
20,263
20,020
20,020
20,094
20,094
21,342
19,613
16,894
16,894
16,956
16,956
17,190
16,812
13,286
13,286
13,332
13,332
13,380
13,380

LEGEND
SH Sensible Heat
TH Total Heat

Performance data (cont)


COOLING CAPACITIES (cont)
42WKN020 4-PIPE
Entering Air (F) Dry Bulb
Entering
Water
Temp (F)

40
45

55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

72

80
Entering Air (F) Wet Bulb
63
67
71
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
23,992
16,123
32,766
15,990
41,896
15,460
25,356
22,440
32,720
22,021
41,844
21,717
15,966
12,581
23,944
12,355
33,726
12,209
20,414
19,373
24,642
18,531
33,680
18,389
10,200
9,353
17,440
8,319
23,596
8,447
16,238
16,157
17,836
15,303
23,710
14,582
16,222
12,734
24,468
12,528
33,836
12,215
20,016
19,355
24,714
18,610
33,788
18,381
10,158
9,467
14,414
8,692
24,462
8,733
16,232
16,216
17,914
15,478
24,416
14,845
6,838
6,797
7,466
5,741
12,534
4,650
12,496
12,496
12,694
12,275
15,126
11,314
5,960
5,960
6,566
5,535
14,392
5,253
12,350
12,350
12,428
12,353
15,392
11,520
2,974
2,974
2,978
2,969
3,742
1,852
8,668
8,668
8,694
8,694
9,002
8,390

5,588
5,588
5,600
5,600
5,612
5,612

42WKN020 4-PIPE (cont)


Entering
Water
Temp (F)

40

45
55

Water
Temp
Rise (F)
10
15
20
10
15
20
10
15
20

Entering Air (F) Dry Bulb


88
Entering Air (F) Wet Bulb
63
67
71
TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh) TH (Btuh) SH (Btuh)
29,160
28,898
33,384
28,143
41,788
27,747
25,862
25,862
27,746
25,193
33,880
24,427
22,498
22,498
23,040
22,141
26,312
21,207
25,508
25,508
17,152
25,088
33,766
24,413
22,362
22,362
22,754
22,162
26,312
21,286
18,952
18,952
19,018
18,980
20,376
18,237
18,404
18,404
18,468
18,468
19,388
18,128
15,140
15,140
15,188
15,188
15,286
15,179
11,460
11,460
11,494
11,494
11,534
11,534

LEGEND
SH Sensible Heat
TH Total Heat

HOT WATER HEATING CAPACITIES (Btuh)


UNIT
SIZE
42WKN
004
008

010

016

020

ENTERING
WATER
TEMP (F)
140
180
140
180
140
180
140*
180*
140
180
140
180
140*
180*

FLOW RATE (GPM)


0.5

1.0

1.5

2.0

3.0

4.0

5.0

6.0

7.0

8.0

10.0

12.0

9,479
15,180
12,260
19,476
12,257
19,498
8,195
13,023
24,694
39,208
24,886
39,680
16,302
25,908

12,538
19,957
17,691
28,047
17,542
27,899
10,162
16,116
35,726
56,632
35,968
57,184
20,194
32,028

13,941
22,165
20,310
32,185
19,982
31,653
11,012
17,437
41,070
65,080
41,118
65,102
21,876
34,640

14,760
23,455
21,850
34,618
21,297
33,713
11,487
18,171
44,220
70,054
43,906
69,496
22,814
36,090

15,682
24,875
23,582
37,338
22,693
35,884
12,003
18,962
47,762
75,622
46,872
74,116
23,834
37,654

16,190
25,659
24,529
38,819
23,414
36,999
12,278
19,384
49,702
78,656
48,408
76,492
24,378
38,486

16,514
26,157
25,127
39,750
23,852
37,673
12,452
19,647
50,928
80,564
49,342
77,930
24,722
39,004

16,740
26,501
25,539
40,391
24,146
38,124
12,571
19,827
51,772
81,876
49,968
78,890
24,956
39,362

16,905
26,754
25,841
40,858
24,357
38,446
12,658
19,959
52,390
82,834
50,416
79,578
25,128
39,622

17,033
26,949
26,072
41,215
24,515
38,688
12,724
20,060
52,862
83,566
50,754
80,094
25,258
39,820

17,217
27,228
26,401
41,724
24,737
39,027
12,818
20,203
53,538
84,610
51,226
80,818
25,444
40,104

17,343
27,420
26,625
42,070
24,886
39,253
12,883
20,300
53,998
85,320
51,542
81,300
25,572
40,296

LEGEND
GPM Gallons Per Minute
*4-pipe units only.
NOTE: Ratings based on nominal airflow (cfm) at 70 F edb, 60 F ewb.

10

Electrical data
UNIT
40WKN

PIPE
VERSION

SINGLE
PHASE
VOLTAGE
(60 Hz)

004

008

OPERATIONAL VOLTAGE

INDOOR FAN

Max*

Min*

Nominal
Hp

208/230

253

187

1/
16

208/230

253

187

1/
16

208/230

253

187

1/
16

208/230

253

187

1/
16

208/230

253

187

1/
16

208/230

253

187

1/
16

208/230

253

187

1/
16

010

016

020

FLA
HACR
Hp
MCA

Speed

Watts

FLA

High
Med
Low
High
Med
Low
High
Med
Low
High
Med
Low
High
Med
Low
High
Med
Low
High
Med
Low

120
85
75
120
85
75
120
85
75
120
90
70
275
185
160
275
185
160
275
190
165

0.60
0.45
0.40
0.60
0.45
0.40
0.60
0.45
0.40
0.60
0.40
0.35
1.20
0.80
0.70
1.20
0.80
0.70
1.20
0.80
0.70

MCA

MAXIMUM FUSE
OR HACR
TYPE BKR AMPS

15

15

15

15

15

15

15

15

15

15

15

15

15

15

LEGEND
Full Load Amps
Heating, Air Conditioning and Refrigeration
Horsepower
Minimum Circuit Amps

*Permissible limits of the voltage range at which units will operate satisfactorily.
NOTE: Two fan motors are used on the 42WKN016,020 units.

11

Typical piping
ACCESSORY VALVE PACKAGE SEAL FITTINGS FOR COIL CONNECTION
230 V MOTORIZED
VALVE

1.8
(45)

4.8
(121 +2)
ENTERING WATER

RETURN WATER

11
(280 +5)

NG

R 4.9
TE (123+5)

WA

RI

TE

EN

OPEN

2
(50+5)

30
ER

N
UR

AT
W

45

RE

1.8
(45+5)

1.6
(40+5)

TUBING 5/8"
FLARE NUT 1/2"

BUSHING 1/2"

INSERT
FERREL
FERREL
INSERT

BUSHING 1/2"
TUBING 5/8"

NOTE: Dimensions are in inches (mm) unless otherwise noted.

12

SHUT-OFF
BALL VALVE 1/2"

Typical wiring schematic


LEGEND
BD
CAP
CKT
CR
CV1
CV2
DR
EQUIP
GND
FR
IFM
NEC
OL
PCB
PDR
PL
PM
PSS
TB
TRAN
WSV

Board
Capacitor
Circuit
Control Relay
Cooling Relay
Heating Relay
Defrost Relay
Equipment Ground

Fan Relay
Indoor Fan Motor
National Electrical Code
Overload
Printed Circuit Board
Pump Delay Relay
Plug
Pump Motor
Pump Shut-Off Switch
Terminal Block
Transformer
Water Solenoid Valve
Terminal (Marked)
Terminal (Unmarked)
Splice
Terminal Block
Factory Wiring
Field Control Wiring
Field Power Wiring
Printed Circuit Board
Accessory or Optional
Wiring

NOTES:
1. If any of the original wire furnished
must be replaced, it must be replaced
with type 90 C wire or its equivalent.
2. Wire in accordance with National Electrical Code (NEC) and local codes.
3. Transformer is thermally protected and
will reset automatically.
4. IFM(s)
are
inherently thermally
protected.
5. Use copper conductors only.
FAN
SPEEDS
LOW
MED
HIGH

ENERGIZED
RELAYS
FR1
FR1 & FR2
FR2

13

Controls
Sequence of operation
Two-pipe systems A 24-v electromechanical relay
printed circuit board (PCB) controls unit operation through
the wall-mounted 24-v solid-state thermostat. When a call
for cooling is initiated by the thermostat, the 24-v signal is
completed between R and Y1. This closes the main control
relay CR1. At the same time, Y1 energizes the pump delay
relay (PDR). The PDR starts the condensate pump. It
allows the condensate pump to run a few seconds after the
relay is deenergized. When CR/Y1 is energized, the water
service valve (WSV1) at 230 v is energized through the
contactor valve (CV1). The WSV is connected between terminal 14 of CR1 and V1 of terminal block 3 (TB3).

14

Four-pipe systems Four-pipe systems operate similarly to 2-pipe systems with the exception that chilled water
and hot water may be sequenced, through two separate
water coils, by means of auto-changeover in the accessory
thermostat. The Carrier duct-free systems (DFS) thermostat will not allow simultaneous operation of chilled and hot
water.

Guide specifications 42WKN hydronic


cassette units
Residential and Commercial Hydronic
Cassette Fan Coil
HVAC Guide Specifications
Size Range: to 2 Tons
Cooling Capacity: 7,000 to 32,000 Btuh
Heating Capacity: 14,000 to 52,000 Btuh
Carrier Model Number: 42WKN
Part 1 General
1.01 SYSTEM DESCRIPTION
Indoor, in-the-ceiling mounted, chilled or hot water
coil, to be matched with a commercial chiller, Water
Source Heat Pumps, or hot water boiler (180 F
maximum). Units shall fit standard 2 ft x 4 ft ceiling
grid.
1.02 QUALITY ASSURANCE
Unit shall be tested and certified in accordance with
ARI Standard 440, and base unit shall be certified by
UL. Each coil shall be factory tested for leakage at
300 psig air pressure with coil submerged in water.
Insulation and adhesive shall meet NFPA-90A
requirements for flame spread and smoke generation. All equipment wiring shall comply with NEC
requirements.
1.03 DELIVERY, STORAGE, AND HANDLING
Unit shall be stored and handled per manufacturers
instructions.
1.04 WARRANTY (One year on parts).
Part 2 Products
2.01 EQUIPMENT
A. General:
Indoor, downward discharge 2 or 4-pipe low-profile
(11-in. high) in-ceiling fan coil. Units shall come
complete with cooling coil or hot water coil (4-pipe
systems only), fan, fan motor, piping connectors,
electrical controls, condensate pump, and hanging
brackets.
B. Unit Cabinet:
Cabinet shall be constructed of zinc-coated steel.
Fully insulated discharge and inlet grilles shall be
attractively styled, high-impact polystyrene. Cabinet
shall have filter tracks and cleanable filters which
shall be accessible from below with a 1/4-turn fastener. Adjacent room cooling to be provided by a
simple knockout in the cabinet side panel, and cabinet shall have provisions to accommodate a limited
amount of ductwork, if desired.
Fan shall be a centrifugal, direct-drive blower type
with air intake in center of the unit and discharge on
the perimeter. Air louvers shall be adjustable for 2, 3
or 4-way discharge.
C. Coil:
Standard base unit shall be equipped with either a
one, 2 or 3 row coil for installation in a 2-pipe system. Additional coil depth and circuiting shall be
provided for installation in a 4-pipe system. Heating
coils are single row, independently circuited coils
specifically designed for hot water application. Heating coil is located downstream from cooling coil.

D.

E.

F.

G.

H.

I.

Coils shall have -in. copper tubes, aluminum fins


bonded to the tubes by mechanical expansion, and a
working pressure of 300 psig. Each coil shall have a
manual air vent on upper connection, a drain port
on the lower screw connection, and screw connections for appropriate OD copper tubes.
Motors:
Motor shall be totally enclosed and permanently
lubricated with inherent protection. Fan motor shall
be 3-speed.
Controls:
Controls shall be 24 v, and shall be easily operated
by the user from a wall-mounted thermostat. A normally closed float control shall be in the condensate
sump to shut unit down in case of pump malfunction. A wall-mounted solid-state 24-v thermostat
with 3 fan speed selections, and an auto./manual
switch shall be available for field installation.
Filters:
Unit shall have a filter track with factory-supplied
cleanable filters.
Electrical Requirements:
Unit shall operate on a 208-v or 230-v, 60 Hz
power supply as specified on the equipment schedule.
Operating Characteristics:
1. A one-coil unit installed in a 2-pipe system shall
be capable of providing cooling as specified by
the operating mode of the central water supply
system. A double-circuit coil unit installed in a
4-pipe system shall be capable of providing
sequenced heating and cooling.
2. The system shall have a minimum listed capacity at ARI conditions.
Special Features (Field-Installed):
1. Power Ventilation Kit and Fresh Air Intake Kit:
Power ventilation kit shall allow ventilation of
the conditioned space with outdoor air. The kit
shall include an in-line booster fan and a solidstate fan speed controller.
2. Fresh Air Intake Kit:
The fresh air intake kit shall include a washable
filter, 6-in. round connection to the unit, and a
guillotine-type damper with incremental positioning label for percentage of outside air
intake.
3. Thermostat:
The thermostat shall be commercial grade to
control unit operation and shall provide 3-speed
fan switchover capability with continuous and
automatic fan operating switch. Automatic
changeover from cooling or heating shall be
provided (4-pipe systems only).
4. Motorized valve accessory:
The motorized valve is a two-position, threeway valve and shall contain preassembled tubing, valve, fittings and valve condensate drip
pan.

15

Carrier Corporation Syracuse, New York 13221

9-05

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 4
Book 1 1 4 4
New
Pg 16
Catalog No. 524-211
Printed in U.S.A.
Form 42WKN-1PD
Replaces: 42WKN-1APD
Tab 4RC5
Tab 3d 3e 2c 2f

S-ar putea să vă placă și