S23 - Substation Relay

20 Series Substation Protection Relay (24-250Vdc & 120-240Vac)

$1,483.00

S40

S40

S40 - Substation Relay

40 Series Substation Protection Relay (24-250Vdc & 120-240Vac)

$2,713.00

S42

S42
S43
S80
S82
S84

S42 - Substation Relay

40 Series Substation (24-250Vdc & 120-240Vac)

$3,559.00

S43 - Substation Relay

40 Series Substation Protection Relay (24-250Vdc & 120-240Vac)

$2,330.00

S80 - Substation Relay

80 Series Substation Protection Relay (24-250Vdc)

$3,570.00

S82 - Substation Relay

80 Series Substation Protection Relay (24-250Vdc)

$3,880.00

S84 - Substation Relay

80 Series Substation Protection Relay (24-250Vdc)

$4,480.00

B21
B22
B80
B83

B21 - Busbar Relay

20 Series Busbar Protection Relay (24-250Vdc & 120-240Vac)

$1,953.00

B22 - Busbar Relay

20 Series Busbar Protection Relay (24-250Vdc & 120-240Vac)

$2,266.00

B80 - Busbar Relay

80 Series Busbar Protection Relay (24-250Vdc)

$3,750.00

B83 - Busbar Relay

80 Series Busbar Protection Relay (24-250Vdc)

$3,950.00

G40
G82
G87
G88
M20
M41
M81
M87
M88
T23
T40
T42
T81
T82
T87
C86

G40 - Generator Relay

40 Series Generator Protection relay (24-250Vdc & 120-240Vac)

$3,609.00

G82 - Generator Relay

80 Series Generator Protection Relay (24-250Vdc)

$3,870.00

G87 - Generator Relay

80 Series Generator Protection Relay (24-250Vdc)

$4,220.00

G88 - Generator Relay

80 Series Generator Protection Relay (24-250Vdc)

$5,222.00

M20 - Motor Relay

20 series Motor Protection Relay (24-250Vdc & 120-240Vac)

$2,009.00

M41 - Motor Relay

40 Series Motor Protection Relay (24-250Vdc & 120-240Vac)

$3,129.00

M81 - Motor Relay

80 Series Motor Protection Relay (24-250Vdc)

$3,240.00

M87 - Motor Relay

80 Series Motor Protection Relay (24-250Vdc)

$3,550.00

M88 - Motor Relay

80 Series Motor Protection Relay (24-250Vdc)

$3,840.00

T23 - Transformer Relay

20 series Transformer Relay (24-250Vdc & 120-240Vac)

$1,957.00

T40 - Transformer Relay

40 Series Transformer Protection relay (24-250Vdc & 120-240Vac)

$2,961.00

T42 - Transformer Relay

40 Series Transformer Protection relay (24-250Vdc & 120-240Vac)

$3,808.00

T81 - Transformer Relay

80 Series Transformer Protection Relay (24-250Vdc)

$3,830.00

T82 - Transformer Relay

80 Series Transformer Protection Relay (24-250Vdc)

$4,130.00

T87 - Transformer Relay

80 Series Transformer Protection Relay (24-250Vdc)

$4,580.00

C86 - Capacitor Bank Relay

80 Series Capacitor Relay (24-250Vdc)

$3,825.00

Advanced Display

Advanced display included in base unit

Basic Display*

Basic display included in base unit

S43
S80
S82
S84
B21
B22
B80
B83

G40
G82
G87
G88
M20
M41
M81
M87
M88
T23
T40
T42
T81
T82
T87
C86

Remote Advanced Display

DSM303

R
B
A

DSM303
MimicBus
CCA634
CCA630

CCA671

C
P
1

MES120
2 x MES120
3 x MES120
MES120G
2 x MES120G
3 x MES120G
MES120H
2 x MES120H
3 x MES120H

0
1
1
1
0
1
2
3
1
2
3
1
2
3

ACE959

MES114
MES114E
MES114F

A
B
C
O
D
E
F
G
H
I
J
K
L
0
1

Remote advanced display (includes 6.5' connection CAT5 cable and base mount kit, AMT840)

$300.00
$0.00
$540.00

Basic Display*

Basic display included in base unit

Advanced Display

Advanced display included in base unit

$300.00

Remote Advanced Display

Remote Advanced Display (includes 6.5' connection CAT5 cable and Base Mount kit, AMT880)

$654.00

$0.00

MimicBus Display

MimicBus Graphical Display

$450.00

5A CT inputs*

1/5A CT inputs (3PH and Ground/Residual or ZSCT)

Alt. 5A CT inputs (requires CSH120, 200 or 30)

1/5A CT inputs (3PH) + (GND/Residual or ZSCT) measurement by CSH120 or CSH200 Zero Sequence CT

Low Power CT (LPCT)

25/3750A LPCT inputs (3PH) + (GND/Residual or ZSCT) measurement by CSH120 or CSH200 Zero Sequence CT (Motor
Starter Only)

without

No I/O module

10In/4Out, 24-48Vdc/120-250Vac

10In/4Out Digital Module (24-48Vdc and 120-250Vac, Capacitor Trip application)

$616.00

10In/4Out, 110-125Vdc/110Vac

10In/4Out Digital Module (110-125 Vdc, 110Vac)

$595.00

10In/4Out, 220-250Vdc/220-240Vac

10In/4Out Digital Module (220-250Vdc, 220-240Vac)

$785.00

without

No I/O module

14In/6Out, 24-48Vdc

1 x 14In/6Out Digital Module (24-48Vdc)

28In/12Out, 24-48Vdc

2 x 14In/6Out Digital Modules (24-48Vdc)

$1,540.00

42In/18Out, 24-48Vdc

3 x 14In/6Out Digital Modules (24-48Vdc)

$2,310.00

14In/6Out, 220-250Vdc

1 x 14In/6Out Digital Module (220-250Vdc/hi p.u.)

28In/12Out, 220-250Vdc

2 x 14In/6Out Digital Modules (220-250Vdc/hi p.u.)

$1,540.00

42In/18Out, 220-250Vdc

3 x 14In/6Out Digital Modules (220-250Vdc/hi p.u.)

$2,310.00

14In/6Out, 110-125Vdc

1 x 14In/6Out Digital Module (110-125Vdc/mid p.u.)

28In/12Out, 110-125Vdc

2 x 14In/6Out Digital Modules (110-125Vdc/mid p.u.)

$1,540.00

42In/18Out, 110-125Vdc

3 x 14In/6Out Digital Modules (110-125Vdc/mid p.u.)

$2,310.00

without

No communications card

1 x RS485

1 x RS485 Modbus port (12 or 24 VDC Power)

$398.00
$275.00

$0.00
$0.00
$531.00
$0.00

$0.00
$770.00

$770.00

$770.00

$0.00

ACE969TP2

2 x RS485

2 x RS485 2wire ports (Port 1 = Modbus, Port 2 = Modbus, DNP3 or IEC 60870, requires 110-240VAC/ 24-250DC ext.
power, includes CCA612 CAT5 cable)

ACE969FO2
ECI850
ACE850

1
1
1

1 x RS485/ 1 x Fiber Optic

1 x RS485 2wire port, 1 x Fiber port (RS485 = Modbus, Fiber = Modbus, DNP3 or IEC 60870, requires 110-240VAC/ 24250DC ext. power, includes CCA612 CAT5 cable)

1 x RS485 (IEC61850)

1 x RS485 IEC61850 communication port

$1,000.00

IEC61850 communications (ACE850)

61850 + Modbus TCPIP Ethernet Module

$900.00

4
5

No temperature sensor inputs (RTD module)

MET1482

0
1

without

8 Temp sensor inputs (One Module)

8 temperature sensor input module (PT_100, NI_100 & NI_120, includes 2' connection CAT5 cable)

MET1482

16 Temp sensor inputs (Two Modules)

2 x 8 temperature sensor input modules (PT_100, NI_100 & NI_120, Includes 2' connection CAT5 cable)

without

No Analog outputs

1 x Analog 0/10mA, 0/20mA, 4/20mA output

1 x Analog output (software selectable 0/10mA, 0/20mA or 4/20mA, includes CCA77X cable)

without

No Logipam programming ability

Logipam Firmware

Logipam firmware (PLC base)

without

No Synch Check Module

Sync-Check Module (required for ANSI-25)

Sync-check Module (required for ANSI-25, includes ATM840 Surface Mount Plate)

MSA141

1
A
B

SFT080
0
1 MSCS025

0
1
0
1
0
1

$771.00

$0.00
$695.00
$1,390.00
$0.00
$631.00
$0.00
$250.00
$0.00
$1,540.00

Sepam Model Selection Tool


Model Number: SQ1 S23 B 1 O 0 A 0 A 0
Device Type

S23 - Substation Relay


Display Type

Basic Display*

Cost of Sepam Unit:

$1,483.00

Provides Protection For:

46
Negative sequence unbalance
50/51
Phase overcurrent
50BF
Breaker failure
50N/51N Ground fault
79
Recloser (4 cycles)

Component Numbers

Includes Metering Values:

Current

Current Option

5A CT inputs*
Digital I/O Option

without
Communications Option

without
RTD Option (Not available on substation or busbar models)

without
Analog Outputs

without
Logipam Programming (Series 80 only)

without
Sync Check Option (ANSI - 25, Series 80 Only)

without
* denotes a default component

Description:
You have selected a (S23) 20 Series Substation Protection Relay (24-250Vdc & 120-240Vac), Basic display
included in base unit, (CCA634) 1/5A CT inputs (3PH and Ground/Residual or ZSCT), No I/O module, No
communications card, No temperature sensor inputs (RTD module), No Analog outputs, No Logipam programming
ability, No Synch Check Module.

Example

Rel
ay

SQ
1

Bas
e

Mo
d el
Dis
pla
y
Cu
r r en
t
I/O
Co
ms
RT
D's
Ana
l og
Ou
t
L og
ipa
m
Syn
ch
Ch
ec k

SEPAM PRICING GUI

SQ1 T87 A 1 J 1 A 1 A

Relay Base
Model

Competition

C86

C86

Competition

S23

S23

S40

S40

S42

S42

Competition
Competition
Competition

S43

S43

S80

S80

S82

S82

S84

S84

B21

B21

B22

B22

B80

B80

B83

B83

G40

G40

G82

G82

G87

G87

G88

G88

M20

M20

M41

M41

M81

M81

M87

M87

M88

M88

T23

T23

T40

T40

T42

T42

T81

T81

T82

T82

T87

T87

Competition
Competition
Competition

Competition

Competition
Competition
Competition
Competition
Competition
Competition
Competition
Competition
Competition
Competition
Competition
Competition
Competition
Competition

Display
A
B
P

MimicBus

DSM303 (Series
20 & 40 Only)

DSM303
80 Only)

(Series

Current
1

CCA634

CCA630

CCA671

I/O for models 20 & 40 (will not work with model 80)
O

without
MES114

MES114E

B
C

MES114F

I/O for models 80 Max. 3 per base unit


O

without

No I/O

MES120

14 Inputs + 6 Outputs Module, 24-48Vdc

MES120

28 Inputs + 12 Outputs Module, 24-48Vdc

MES120

42 Inputs + 18 Outputs Module, 24-48Vdc

MES120G

14 inputs + 6 outputs, 220-250Vdc/hi p.u.

MES120G

28 inputs + 12 outputs, 220-250Vdc/hi p.u.

MES120G

42 inputs + 18 outputs, 220-250Vdc/hi p.u.

MES120H

14 inputs + 6 outputs, 110-125Vdc/mid p.u.

MES120H

28 inputs + 12 outputs, 110-125Vdc/mid p.u.

MES120H

42 inputs + 18 outputs, 110-125Vdc/mid p.u.

Communications
0

without

ACE959
ACE969TP2

ACE969FO2

3
4

ECI850

ACE850

RTD
A

used only for the following applications: Motor, Generator, Capacitor or Tra

without
MET1482 (One
Module)

MET1482 (Two
Modules)

Analog Output
0

without

MSA141

Series 80 Options
A

without

SFT080
0

without

SQ1 T87 A 1 J 1 A 0 A

MCS025

0
Accessories - Not to be included in the relay part number
RTM

3090RTM317

CSH30

CSH30

CSCT120

CSH120

CSCT200

CSH200

EGX100

EGX100

EGX400

EGX400

ECI850

ECI850

ACE850

ACE850
ABL8RPS24030
ABL8RPS24050

Software
SFT2841KIT

SFTKIT

SFT2841KIT

RICING GUIDE
Description

List Price

Capacitor
80 Series Capacitor Relay, 24-250Vdc

$3,825.00

Compare Substation Relays


20 Series Substation Protection Relay, 24-250Vdc & 120-240Vac

$1,483.00

40 Series Substation Protection Relay, 24-250Vdc & 120-240Vac

$2,713.00

40 Series Substation, 24-250Vdc & 120-240Vac


Applincation: Substation - S40A + Directional 67, 67N protection. Parallel main protection. ZSI
and ATS

$3,559.00

40 Series Substation, 24-250Vdc & 120-240Vac

$2,330.00

80 Series Substation Protection Relay, 24-250Vdc

$3,570.00

80 Series Substation Protection Relay, 24-250Vdc

$3,880.00

80 Series Substation Protection Relay, 24-250Vdc

$4,480.00

Compare Busbar Relays


20 series Busbar Protection Relay 24-250Vdc & 120-240Vac

$1,953.00

20 series Busbar Protection Relay 24-250Vdc & 120-240Vac

$2,266.00

80 Series Busbar Protection Relay, 24-250Vdc

$3,750.00

80 Series Busbar Protection Relay, 24-250Vdc

$3,950.00

Compare Generator Relays


40 Series Generator Protection relay, 24-250Vdc & 120-240Vac

$3,609.00

80 Series Generator Protection Relay, 24-250Vdc

$3,870.00

80 Series Generator Protection Relay, 24-250Vdc

$4,220.00

80 Series Generator Protection Relay, 24-250Vdc

$5,222.00

Compare Motor Relays


20 series Motor Protection Relay 24-250Vdc & 120-240Vac

$2,009.00

40 Series Motor Protection Relay, 24-250Vdc & 120-240Vac,

$3,129.00

80 Series Motor Protection Relay, 24-250Vdc,

$3,240.00

80 Series Motor Protection Relay, 24-250Vdc,

$3,550.00

80 Series Motor Protection Relay, 24-250Vdc,

$3,840.00

Compare Transformer Relays


20 series Transformer Relay 24-250Vdc & 120-240Vac

$1,957.00

40 Series Transformer Protection relay, 24-250Vdc & 120-240Vac

$2,961.00

40 Series Transformer Protection relay, 24-250Vdc & 120-240Vac

$3,808.00

80 Series Transformer Protection Relay, 24-250Vdc

$3,830.00

80 Series Transformer Protection Relay, 24-250Vdc

$4,130.00

80 Series Transformer Protection Relay, 24-250Vdc

$4,580.00

Advanced display included in base unit


Standard LED Display included in base uniit

$300.00
$0.00

MimicBus Graphical Display (for series 80 only)

$450.00

Remote Display includes 6.5' connection CAT5 cable and Base Mount kit for Series 20/40
AMT840 (Replaces integrated display)

$540.00

Remote Display includes 6.5' connection CAT5 cable and Base Mount kit for Series 80
AMT880 (Replaces integrated display)

$654.00

5A input standard on relays for current measurement, not included on voltage only relays
Only for use with CSH120, 200 ground fault sensor, and CSH30
25/3750A LPCT Connector for All SEPAM Series
Note: Used with Motorpact or other medium voltage starter, includes CSH30

$0.00
$0.00
$531.00

will not work with model 80)


$0.00

No I/O
10 Inputs + 4 Outputs Module, 24-48Vdc and 120-250V ac Capacitor Trip application
10 Inputs + 4 Outputs Module, 110-125 Vdc, 110Vac
10 Inputs + 4 Outputs Module, 220-250Vdc, 220-240Vac

3 per base unit

$616.00
$595.00
$785.00

(will not work with models 20 & 40)


$0.00

Inputs + 6 Outputs Module, 24-48Vdc (Model 80 Only)

$770.00

Inputs + 12 Outputs Module, 24-48Vdc (Model 80 Only)

$1,540.00

Inputs + 18 Outputs Module, 24-48Vdc (Model 80 Only)

$2,310.00

inputs + 6 outputs, 220-250Vdc/hi p.u. (Model 80 Only)

$770.00

inputs + 12 outputs, 220-250Vdc/hi p.u. (Model 80 Only)

$1,540.00

inputs + 18 outputs, 220-250Vdc/hi p.u. (Model 80 Only)

$2,310.00

inputs + 6 outputs, 110-125Vdc/mid p.u. (Model 80 Only)

$770.00

inputs + 12 outputs, 110-125Vdc/mid p.u. (Model 80 Only)

$1,540.00

inputs + 18 outputs, 110-125Vdc/mid p.u. (Model 80 Only)

$2,310.00

No communications card

$0.00

1 RS 485 Modbus Port (12 or 24 VDC Power) included with all relays

$398.00

(2)RS485 2wire ports, Port 1 Modbus, Port 2 Modbus, DNP3 or IEC 60870 (requires 110240VAC/ 24-250DC ext. power). Includes CCA612 CAT5 cable.

$275.00

(1) RS485 2wire Modbus + (1) Fiber Modbus, DNP3 or IEC 60870 (requires110-240VAC/ 24250DC). Includes CCA612 CAT5 cable.
1 x RS485 IEC 61850 protocol port

$771.00
$1,000.00

61850 + Modbus TCPIP Ethernet Module (not currently availible)

ing applications: Motor, Generator, Capacitor or Transformer

No RTD module
8 temperature sensor input module PT_100, NI_100 & NI_120, Includes 2' connection CAT5
cable. Note: Series 20, 40 & 80
16 temperature sensor input module PT_100, NI_100 & NI_120, Includes 2' connection CAT5
cable. Note: Series 40 & 80 only

No Analog Output
1 Analog output module, software selectable 0/10mA, 0/20mA or 4/20mA (includes CCA77X
cable)
No Logipam
Logipam firmware (PLC base)
No Synch Check Module

$0.00
$695.00
$1,390.00

$0.00
$631.00
$0.00
$250.00
$0.00

Sync-check Module_ANSI-25 for model 80 only (includes ATM840 Surface Mount Plate)

$1,540.00

ncluded in the relay part number


Ride Through Module Recommented for AC control voltage application (for all series 20, 40
and 80)

$574.00

Interposing CT for Residual ground current input, use with LPCT

$116.00

Ground sensor CT - 120mm window (zsct)

$235.00

Ground sensor CT - 200mm window (zsct)

$378.00

Ethernet Gateway; RS-485/RS232, 10/100 BASE TX Transparent ready

$950.00

Ethernet Gateway;(2) RS-485 serial ports,10/100T,100FX (Fiber),8 imbedded web pages,


Modbus Protocol

$2,460.00

1 Ethernet port 10/100 base T (Protocol: Modbus or IEC 61850) (Requires ACE Com Card)

$850.00

2 Ethernet ports 10/100 base T Only for Series 80 (Protocol: Modbus or IEC 61850) does not
require ACE Com Card

$850.00

Power Supply: Input 110-480VAC, Output 24VDC 3A_for upto 15 comm module

$180.00

Power Supply: Input 110-480VAC, Output 24VDC 5A_for upto 25 comm module

$240.00

Relay Programming Software includes CD w/relay connector cable & USB / Serial cable,
necessary for programming and troubleshooting relays)

$275.00

Relay Programming Software includes SFT 2841 CD & SFT 2885 Logipam programming CD
w/relay connector cable & USB / Serial cable Note: must have Logipam option on a series 80
relay to use Logipam programming software

$495.00

Note: SFT2841 to be a free download (like ION Setup). The kit includes the program on a
disk and the connection cables. Kit price may be reduced

General Selection Guide


Protection Functions
Base

Specific

Current Protections
Breaker Failure

Applications
Substation

T20

S23

T23
B21

disconnection by "rate of
change of frequency"

Specific

Current, Voltage and


Frequency Protection
directional ground fault
directional ground fault and
phase overcurrent
Base

Specific

Current, Voltage and


Frequency Protection

Current, Voltage and


Frequency Protection

Transformer

S20

Voltage and Frequency


Protection

Base

Bus

B22

Substation

Bus

Transformer

S40

T40

S41
S42

T42

Substation

Bus

S80

B80

Transformer

directional ground fault

S81

T81

directional ground fault and


phase overcurrent

S82

T82

disconnection by "rate of
change of frequency"
Transformer and
transformer-machine unit
differential

S84
T87

Machine Differential

Current, Voltage and


Frequency Protection

Voltage and frequentcy


protection for two sets of
bus

Current, Voltage and


Frequency Protection

Capacitor bank unbalance

B83

Motor

Generator

Capacitor

Generator

Capacitor

M20

Motor

G40
M41

Motor

Generator

Capacitor

M81

G82

M88

G88

M87

G87

C86

SEPAM Links:
SEPAM Software downloads
SEPAM Tech Library; docs, curves and specifications
SEPAM Knowledgebase and FAQ's
Series 20 control voltage
24-250V DC, or 110-220V AC (for AC use RTM
#3090RTM317)
SEPAM Relays Series 20
Voltage/Frq Protection Only
SQ1B21A
Bus - Voltage and Frequency

Series 40 control voltage


24-250V DC, or 110-220V AC (for AC use RTM
#3090RTM317)
SEPAM Relays Series 40

Series 80 control voltage


24-250V DC, for 110-220V AC (use RTM
#3090RTM317)
SEPAM Relays Series 80

SQ1G40A

SQ1C86A

protection and ATS

Current Protection Only


SQ1M20A
Motor, FVNR, FVR 100-1500HP-

Generator - Current, Voltage and


Frequency Protection of a separate
generator. For Gen-self-balance Diff "87M"
add Basler BE3-50/51.

SQ1M41A

Current protection without voltage


monitoring

Motor, FVNR, RVAT, FVR, FV2S, FR

Capacitor bank - Double-wye connected


protection with 1 to 4 steps

SQ1G82A

500- 5000HP - Current protection with


voltage monitoring. For motor self-balance
Diff "87M" add Basler BE3-50/51.

Generator Protection coupled to other


generators or to a network

Current Protection Only


SQ1S23A
Substation - Current, protection of low-

SQ1S40A

Substation - Current & Voltage,

SQ1G87A

Generator - Current protection with

Current Protection Only


SQ1T23A
Transformer - Current protection without

SQ1S42A

Substation - (S40A + Directional 67, 67N)

SQ1G88A

Generator-transformer unit differential

capacitance Feeders / Mains


in impedance grounded or solidly grounded
neutral systems. Capacitor feeder bank
(delta connection)

voltage monitoring

protection of low-capacitance Feeders /


Mains in impedance grounded or solidly
grounded neutral systems. Capacitor bank
(delta connection)

protection. Parallel main protection, ZSI and


ATS

SQ1T40A

Transformer - Current and voltage

protection

SQ1M81A

protection.

SQ1T42A

Transformer - (T40A + Directional 67,

voltage monitoring and gen self-balance Diff


"87M" or full percentage diff

Motor feeder - Current protection with


voltage monitoring. For motor self balance
Diff "87M" add Basler BE3-50/51.

SQ1M87A

67N). Current and voltage + Directional.


Parallel transformer main protection

Motor - (M81 + 87M)Current protection


with voltage monitoring and motor self
balance Diff "87M" or full percentage diff

SQ1M88A

Motor-transformer unit differential

SQ1S80A

Substation - Current & Voltage,

protection

protection of low-capacitance Feeders /


Mains in impedance grounded or solidly
grounded neutral systems

SQ1S82A

Substation - (S80A + Directional 67,


67N). Protection of main or tie CB with load
shedding, ZSI & ATS

SQ1S84A

Substation - (S80A + Directional 67, 67N,


27,59, 59N, 81L, 81R, 32P, 37P). Protection
of main or tie CB with load shedding, ZSI &
ATS

SQ1T82A

Transformer - Current and voltage +


Directional. Parallel transformer main
protection

SQ1T87A

Transformer - (T82 + 87T). Current and


voltage + Directional. Parallel transformer
main & differential protection

Comparison of ANSI features on Busbar Protection Relays


ANSI
25
27
27D
27R
27S
30
46
47
50/51
50BF
50N/51N
50G/51G
59
59N
81H
81L
81R

Protection Functions
Synch-check
Undervoltage (L-L)
Positive sequence undervoltage
Remanent undervoltage
Undervoltage (L-N)
Annunciation
Negative sequence / unbalance
Negative Sequence Overvoltage
Phase Overcurrent
Breaker Failure
Ground Fault
Sensitive Ground Fault
Overvoltage (L-L or L-N)
Neutral voltage displacement
Overfrequency
Underfrequency
Rate of change of frequency (df/dt) _ (SQ1B22A

86
94/69

Latching, Lockout
CB_Control Logic

only_use with Gen application)

B21

B22

B80

B83

2/1 (3)
2
1

2/1 (3)
2
1

4
2
2

4
2
2

2
2
8
1
8

2
2
8
1
8

4
2
2
4

4
2
2
4

2
2
1
2

2
2
1
2
1

Note: The numbers in the matrix denote the number of trip points that can be
configured for this ANSI code.
Optional
(1) Protection functions with 2 groups of settings
(2) With optional MSC025 Synch Check Module
(3) 2 Undervoltage (L-L) and 1 undervoltage (L-N)

The Difference between B80 and B83?


B83: monitors Line and Bus voltage
(2 sets of VT's)

Metering Parameters
Metering Values
Current 1,2,3

Current Peak Demand


Current Demand
Current Residual
Voltage L-N & L-L

Acc.

B80
X
X
X
X
X

B83
X
X
X
X
X

X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X

+ - 1 Deg

+- 1 Deg C

+- 1 Deg C

+-1%
+-1%
+-1%
0.01

X
X
X
X

X
X
X
X

KVArh (Pulse Counting)


KVAh

+-1%
+-1%

Frequency

.01Hz

Rotation Speed

-1 - 0 - +1

X
X

X
X

+-1%
+-1%
+-1%
+-1%
+ - 2%
+ - 2%
+-1%
+-1%
+-1%
+-1%
+-1%
+-1%

Power Factor

B22

+ - .5%

Voltage Residual
Neutral Point Voltage
Voltage Neg. Sequence 1,2,3
Voltage Pos. Sequence 1,2,3
KW
KVA
KVAr
KWh (Calculated)
KVArh (Calculated)
KWh (Pulse Counting)

Temperature
Harmonic distortion (I THD & V THD)
Peak KW demand
Peak KVAr demand

B21

+ - .5%
+ - .5%
+ - .5%

+ - 1 RPM

Comparison of ANSI features on Generator Protection Relays


ANSI
12
14
21B
24
25
26/63
27/27S
27D
27R

Protection Functions
Overspeed (2 set points)
Underspeed (2 set points)
Underimpedance
Flux control (V/Hz)
Synch-check
Thermostat / Buchholz
Undervoltage (L-L or L-N)
Positive sequence undervoltage
Remanent undervoltage

27TN/64G2
64G
30
32P
32Q/40/55
37P

Third Harmonic Undervoltage & 100% stator


ground fault
Annunciation
Directional active overpower
Directional reactive overpower
Directional active overpower

38/49T

Temperature monitoring

40
46
47

Field loss underimpedance


Negative sequence unbalance
Negative sequence overvoltage
Thermal overload
Inadvertant energization
Phase overcurrent
Breaker failure

49RMS
50/27
50/51
50BF
50N/51N
50G/51G
50V/51V
59
59N
60/60FL
64REF
67
67N/67NC
68
74
78PS
81H
81L
86
87M
87T
94/69

G40

1
1

8 RTD's

Ground fault / Sensitive ground fault


Voltage restrained phase overcurrent
Overvoltage (L-L or L-N)
Neutral voltage displacement
CT/VT supervision
Restricted ground fault
Directional phase overcurrent
Directional ground fault
Zone Selective Interlock (ZSI)
Trip circuit supervision
Pole slip (loss of synch)
Overfrequency
Underfrequency
Latching, Lockout
Machine Differential
Transformer differential
CB_Control Logic

2
1
2
4
1
4
1
2
2
Y

2
4

G82

G87

G88

1
2

1
2

1
2

4
2
2

4
2
2

4
2
2

2
1
2

2
1

2
1

16 RTD's 16 RTD's 16 RTD's


1
1
1
2
2
2
2
2
2
2
2
2
1
1
8
8
8
1
1
1
8
2
4
2
Y
2
2
2

8
2
4
2
Y
2
2

8
2
4
2
Y
2
2
2

1
2
4

1
2
4

1
2
4

1
1

Note: The numbers in the matrix denote the number of trip points that can be configured for this ANSI
code.
Optional Modules
(1) Protection functions with 2 groups of settings
(2) According to parameter setting and optional input/output modules
(3) With optional MET1482 temperature input modules
(4) With optional MCS025 synchro-check module

Metering Parameters
Metering Values
Current 1,2,3

Accuracy
+ - .5%
+ - .5%
+ - .5%

G40
X
X
X
X
X
X
X
X

G82
X
X
X
X
X
X
X
X
X

G87
X
X
X
X
X
X
X
X
X

G88
X
X
X
X
X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

X
X
X
X
X

Current Peak Demand


Current Demand
Current Residual
Voltage L-N & L-L
Voltage Residual
Neutral Point Voltage
Voltage Neg. Sequence 1,2,3
Voltage Pos. Sequence 1,2,3

+-1%
+-1%
+ - 2%
+ - 2%

KW
KVA
KVAr
KWh (Calculated)
KVArh (Calculated)

+-1%
+-1%
+-1%
+-1%
+-1%

X
X
X
Op
Op

KWh (Pulse Counting)


KVArh (Pulse Counting)
KVAh

+-1%
+-1%
+-1%

Op
Op

.01Hz
+ - 1 Deg

X
Op
X
X
X
X

Frequency
Temperature
Harmonic distortion (I THD & V THD)
Peak KW demand
Peak KVAr demand

Power Factor
Rotation Speed

-1 - 0 - +1

+-1%
+ - .5%

+-1%
+-1%
+-1%
0.01
+ - 1 RPM

+- 1 Deg C +- 1 Deg C +- 1 Deg C

X
X
X
X

X
X
X
X

X
X
X
X

Comparison of ANSI features on Motor Protection Relays


ANSI
12
14
21B
24
25
26/63
27/27S
27D
27R

Protection Functions
Overspeed (2 set points)
Underspeed (2 set points)
Underimpedance
Flux control (V/Hz)
Synch-check
Thermostat / Buchholz
Undervoltage (L-L or L-N)
Positive sequence undervoltage
Remanent undervoltage

27TN/64
G2 64G

Third Harmonic Undervoltage &


100% stator ground fault

30
32P
32Q/40/55
37
37P

Annunciation
Directional active overpower
Directional reactive overpower
Phase undercurrent
Directional active overpower

38/49T

Temperature monitoring

40
46
47
48/51LR/
14

Field loss underimpedance


Negative sequence unbalance
Negative sequence overvoltage

49RMS
50/27
50/51
50BF
50N/51N
50G/51G
50V/51V
59
59N
60/60FL
64REF
66
67
67N/67NC
68
74
78PS
81H
81L
86
87M
87T
94/69

Thermal overload
Inadvertant energization
Phase overcurrent
Breaker failure

Excessive starting time, locked rotor

Ground fault / Sensitive ground fault


Voltage restrained phase overcurrent
Overvoltage (L-L or L-N)
Neutral voltage displacement
CT/VT supervision
Restricted ground fault
Starts per hour
Directional phase overcurrent
Directional ground fault
Zone Selective Interlock (ZSI)
Trip circuit supervision
Pole slip (loss of synch)
Overfrequency
Underfrequency
Latching, Lockout
Machine Differential
Transformer differential
CB_Control Logic

M20

8 RTD's
1

M81

M87

M88

4
2
2

4
2
2

4
2
2

2
1
1

2
1
1

2
1
1

16 RTD's 16 RTD's 16 RTD's


1
1
1
2
2
2
2
2
2

1
2

1
2

1
2

1
2

8
1

8
1

8
1

4
2
Y

4
2
Y

4
2
Y

1
2
4

1
2
4

1
2
4

1
1

Note: The numbers in the matrix denote the number of trip points that can be configured
for this ANSI code.

Optional Modules
(1) Protection functions with 2 groups of settings
(2) According to parameter setting and optional input/output modules
(3) With optional MET1482 temperature input modules
(4) With optional MCS025 synchro-check module

Metering Parameters
Metering Values

M81
X

M87
X

M88
X

+-1%

X
X
X

X
X
X

X
X
X

Neutral Point Voltage


Voltage Neg. Sequence 1,2,3
Voltage Pos. Sequence 1,2,3
KW
KVA
KVAr

+-1%
+ - 2%
+ - 2%
+-1%
+-1%
+-1%

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

KWh (Calculated)
KVArh (Calculated)
KWh (Pulse Counting)
KVArh (Pulse Counting)

+-1%
+-1%
+-1%
+-1%

X
X

X
X

X
X

KVAh

+-1%
X

Current 1,2,3

Current Peak Demand


Current Demand
Current Residual
Voltage L-N & L-L
Voltage Residual

Frequency
Temperature
Harmonic distortion (I THD & V THD)
Peak KW demand
Peak KVAr demand

Power Factor
Rotation Speed

-1 - 0 - +1

Acc.
+ - .5%
+ -1%
+ - .5%
+ -1%
+ - .5%
+ -1%
+ -1%
+ - .5%

.01Hz
+ - 1 Deg

+-1%
+-1%
+-1%
0.01
+ - 1 RPM

M20
X
X
X
X

+- 1 Deg C +- 1 Deg C +- 1 Deg C

X
X
X
X

X
X
X
X

X
X
X
X

Comparison of ANSI features on Substation Protection Relays


ANSI
21B
24
25
26/63
27/27S
27D
27R

Protection Functions
Underimpedance
Flux control (V/Hz)
Synch-check
Thermostat / Buchholz
Undervoltage (L-L or L-N)
Positive sequence undervoltage
Remanent undervoltage

27TN/64
G2 64G

Third Harmonic Undervoltage & 100% stator


ground fault

30
32P
32Q/40/55
37
37P

Annunciation
Directional active overpower
Directional reactive overpower
Phase undercurrent
Directional active overpower

38/49T

Temperature monitoring

40
46
47

Field loss underimpedance


Negative sequence unbalance
Negative sequence overvoltage

49RMS
50/27
50/51
50BF
50N/51N
50G/51G
50V/51V
59
59N
60/60FL
64REF
66
67
67N/67NC
68
74
78PS
79
81H
81L
81R
86
87M
87T
94/69

Thermal overload
Inadvertant energization
Phase overcurrent
Breaker failure
Ground fault / Sensitive ground fault

S23

S40

S41

S42

8 RTD's 16 RTD's 16 RTD's 16 RTD's


1

2
1

2
1

2
1

4
1

4
1

4
1

4
1

2
2
Y

2
2
Y

2
2
Y

2
2

2
4

2
4

Voltage restrained phase overcurrent


Overvoltage (L-L or L-N)
Neutral voltage displacement
CT/VT supervision
Restricted ground fault
Starts per hour
Directional phase overcurrent
Directional ground fault
Zone Selective Interlock (ZSI)
Trip circuit supervision
Pole slip (loss of synch)
Recloser ( 4 shots )
Overfrequency
Underfrequency
Rate of change of frequency
Latching, Lockout
Machine Differential
Transformer differential
CB_Control Logic

2
4

Note: The numbers in the matrix denote the number of trip points that can be configured for this ANSI code.
Optional Modules
(1) Protection functions with 2 groups of settings
(2) According to parameter setting and optional input/output modules

(3) With optional MET1482 temperature input modules


(4) With optional MCS025 synchro-check module

ection Relays
S80

Metering Parameters
S82

S84

Metering Values

Acc.

Current 1,2,3

+ - .5%

Current Peak Demand

+ - .5%

+-1%
+-1%
4
2
2

4
2
2

4
2
2

2
16 RTD's 16 RTD's 16 RTD's
2
2

2
2
2

2
2
2

8
1

8
1

8
1

4
2
Y

2
4

or this ANSI code.

4
2
Y

4
2
Y

2
2

2
2

2
4

2
4
2

Current Demand

+ - .5%

Current Residual

+-1%
+-1%

S23

S40
X

X
X
X
X
X
X

Voltage L-N & L-L


Voltage Residual
Neutral Point Voltage
Voltage Neg. Sequence 1,2,3
Voltage Pos. Sequence 1,2,3
KW

+-1%
+-1%
+ - 2%
+ - 2%
+-1%

KVA
KVAr
KWh (Calculated)
KVArh (Calculated)
KWh (Pulse Counting)
KVArh (Pulse Counting)
KVAh

+-1%
+-1%
+-1%
+-1%
+-1%
+-1%
+-1%

X
X
X
X
X
X

.01Hz
+ - 1 Deg

Frequency
Temperature
Harmonic distortion (I THD & V THD)
Peak KW demand
Peak KVAr demand

Power Factor
Rotation Speed

-1 - 0 - +1

+ - .5%

+-1%
+-1%
+-1%
0.01
+ - 1 RPM

X
X
X
X
X

X
X
X

g Parameters
S41
X

S42
X

S80
X

S82
X

S84
X

X
X

X
X

X
X
X

X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X

X
X
X
X

X
X
X
X

X
X
X

X
X
X

+- 1 Deg C

+- 1 Deg C

+- 1 Deg C

X
X
X
X

X
X
X
X

X
X
X
X

Comparison of ANSI features on Transformer Protection Relays


ANSI
25
26/63
27/27S
27D
27R
30
32P
32Q/40/55
37
37P

Protection Functions
Synch-check
Thermostat / Buchholz
Undervoltage (L-L or L-N)
Positive sequence undervoltage
Remanent undervoltage
Annunciation
Directional active overpower
Directional reactive overpower
Phase undercurrent
Directional active overpower

38/49T

Temperature monitoring

40
46
47

Field loss underimpedance


Negative sequence unbalance
Negative sequence overvoltage
Thermal overload
Inadvertant energization
Phase overcurrent
Breaker failure

49RMS
50/27
50/51
50BF
50N/51N
50G/51G
50V/51V
59
59N
64REF
67
67N/67NC
68
74
81H
81L
81R
86
87M
87T
94/69

T23

8 RTD's

Ground fault / Sensitive ground faul


Voltage restrained phase overcurrent
Overvoltage (L-L or L-N)
Neutral voltage displacement
Restricted ground fault
Directional phase overcurrent
Directional ground fault
Zone Selective Interlock (ZSI)
Trip circuit supervision
Overfrequency
Underfrequency
Rate of change of frequency
Latching, Lockout
Machine Differential
Transformer differential
CB_Control Logic

T40

T42

T81

T82

4
2
2

4
2
2

16 RTD's 16 RTD's 16 RTD's 16 RTD's

2
1
2

2
1
2

2
2
2

2
2
2

4
1

4
1

4
1

8
1

8
1

2
2

2
2

4
2
2

2
4

2
2

4
2
2
2
2

2
4

2
4

2
4

Note: The numbers in the matrix denote the number of trip points that can be configured for this
ANSI code.
Optional Modules
(1) Protection functions with 2 groups of settings
(2) According to parameter setting and optional input/output modules
(3) With optional MET1482 temperature input modules
(4) With optional MCS025 synchro-check module

Metering Parameters
Metering Values

Acc.

T40
X

T42
X

T81
X

T82
X

X
X
X

X
X
X

X
X
X
X

X
X
X
X

+ - 2%
+ - 2%
+-1%
+-1%
+-1%
+-1%
+-1%
+-1%
+-1%
+-1%

X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X
X
X

X
X
X
X
X
X
X

X
X
X
X
X
X
X

.01Hz
+ - 1 Deg

Current 1,2,3

+ - .5%

Current Peak Demand

+ - .5%

Current Demand

+ - .5%

+-1%
+-1%

Current Residual
Voltage L-N & L-L
Voltage Residual
Neutral Point Voltage
Voltage Neg. Sequence 1,2,3
Voltage Pos. Sequence 1,2,3
KW
KVA
KVAr
KWh (Calculated)
KVArh (Calculated)
KWh (Pulse Counting)
KVArh (Pulse Counting)
KVAh
Frequency
Temperature
Harmonic distortion (I THD & V THD)
Peak KW demand
Peak KVAr demand

Power Factor
Rotation Speed

-1 - 0 - +1

+-1%
+-1%
+ - .5%

+-1%
+-1%

+-1%
+-1%
+-1%
0.01
+ - 1 RPM

T23
X
X
X
X

X
X
X

X
X
X

+- 1 Deg C

+- 1 Deg C

X
X
X
X

X
X
X
X

ANSI codes
12
Overspeed
14
Underspeed
21B
Underimpedance
24
Flux control (V/Hz)
25
Check synchro
26/63 Thermostat/Buchholtz
27
Undervoltage (L-L)
27/27S Undervoltage (L-L or L-N)
27D
Positive sequence undervoltage
27R
Remanent undervoltage
27S
Undervoltage (L-N)
27TN/64G2 Third harmonic undervoltage
32P
Directional active overpower
32Q
Directional reactive overpower
32Q/40 Directional reactive overpower
37
Phase undercurrent
37P
Directional active underpower
38/49T Temperature monitoring
40
Field loss underimpedance
46
Negative sequence unbalance
47
Negative sequence overvoltage
48
Excessive starting time
48/51LR Excessive starting time, locked rotor
49RMS Thermal overload
50/27
Inadvertant energization
50/51
Phase overcurrent
50BF
Breaker failure
50G/51G Sensitive ground fault
50N/51N Ground fault
50V/51V Voltage restrained phase overcurrent
51C
Maximum unbalance current
51LR
Locked rotor
59
Overvoltage (L-L or L-N)
59N
Neutral voltage displacement
60/60FL CT/VT supervision
64G
100% stator ground fault
64REF Restricted ground fault
66
Starts per hour
67
Directional phase overcurrent
67N/67NC Directional ground fault
78PS
Pole slip
79
Recloser (4 cycles)
81H
Overfrequency
81L
Underfrequency
81R
Rate of change of frequency (df/dt)
87M
Machine differential
87T
Transformer differential

S23 S40 S42 S43 S80 S82 S84 B21 B22 B80 B83 G40 G82 G87 G88 M20 M41 M81 M87 M88 T23 T40 T42 T81 T82 T87 C86

x
x
x

x
x

x
x

x
x

x
x

x
x
x
x
x
x

x
x
x
x
x

x
x

x
x

x
x
x

x
x
x

x
x

x
x

x
x

x
x

x
x

x
x
x

x
x
x

x
x
x

x
x
x

x
x
x
x

x
x
y
x

x
x

x
x
y
x

x
x

x
x
y
x

x
x
x

x
x

x
x
y
x

x
x

x
x

x
x
y
x

x
x
y
x

x
x

x
x

x
x

x
x
x
y
x

x
x
y
x

x
x
y
x
x

x
x
x
x
x

x
x
x
x

x
x
x
x

x
x
x
x
y
x
x

x
x
x
x
y
x
x

x
x
x
x
y
x
x

x
x

x
x

x
x
x

x
x
x
x
x
y
x

x
x

x
x

x
x

x
x
x

x
x
x

x
x
x
x

x
x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x
x
x

x
x
x
x

x
x

x
x

x
x
x
x

x
x

x
x

x
x

x
x

x
x
y
x

x
x
y
x

x
x
y
x

y
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x
y
x

x
x
y
x

x
x
y
x

x
x
y
x

x
x
y
x

x
x
y
x

x
x
y
x

x
x
y
x
x

x
x
y

x
x
y

x
x
y

x
x
y

x
x
y

x
x

x
x

x
x
x

x
x
x
x

x
x

x
x

x
x
y

x
x
y

x
x
y

x
x
y
y
x

x
x
y
y

x
x
y
y
x

x
x
x

x
x
x

x
x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x
x
x

x
x
x

x
x
x

x
x

x
x
x

x
x

x
x
x

x
x

x
x

x
x

x
x
y

x
x
y

x
x
y

x
x
y

x
x
y

x
x

x
x
y

x
x
y

x
x
y

x
x
y

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x
y

x
x