Documente Academic
Documente Profesional
Documente Cultură
Electrical operation
Size 5
Series MDM-5
FEATURES
* Pressure reducing over the whole range independent of the supply pressure.
* Several sub-plates available.
* Conversion to ISO/CETOP mounting surface.
* Several control pressure ranges available.
* Different pressure ranges for the two pilot lines possible.
* Proportional solenoids with longer life for the armature in the oil.
* Several types of proportional solenoids, such as explosion proof II 2 G EEx m II T4 and IP67.
* Adjustable valve response time.
TECHNICAL DATA
- maximum operating pressure conn. P
- maximum return pressure conn. T
- pressure range conn. A and B
- flow range
- viscosity range
- contamination level max.
- ambient temperature
- mounting position
- fluid
- mounting surface roughness
- mounting surface flatness
- nominal voltage
- nominal current
- valve response time
- hysteresis
- resolution
- continuous operation
- seals
100 Hz
DIAGRAMS
Publ.MDM-5-03-06
ORDERING CODE
MDM 5
MDM - 5 - 70 - 190 - B / Viton
DUAL TYPE
SERIES
MDM-5
CONTROL PRESSURE RANGE, DUAL TYPE:
Port A in bar *: 12, 30, 70, 120, 190 or 350 bar
Example: MDM-5-70-70/B
SINGLE TYPE
SOLENOID TYPE
A = 12V DC IP65 with emergency control by pin
B = 24V DC IP65 with emergency control by pin
E = 12V DC IP65 with emergency control by button
F = 24V DC IP65 with emergency control by button
H = 24V DC IP57 II 2 G EEx m II T4 (Explosion Proof)
J = 24V DC IP67, without female connector
Example: MDM-5-350/B
OPTIONS
Viton = With Viton seals
SUB-PLATE
A-5-DM - 3 / Viton
SUBPLATE
SERIES
A-5-DM = Sub-plate
NUMBER
1-8 = choose number of MDM-5 valve which
has to be mounted on one subplate (up to 8)
OPTIONS
SAE = S.A.E. straight thread 'O'RING BOSS
Viton = With Viton seals
CONVERSION PLATE
A-5-PS / Viton
SERIES
A-5-PS = Conversion to ISO/CETOP 3 model
OPTIONS
Viton = With Viton seals
RECOMMENDED SPARE PARTS
R - .. - 016
R SPARE KIT
01
06
11
16
SEALS (BUNA-N)
ASSEMBLY KIT:SEALS (BUNA-N) AND SCREWS
SEALS (VITON)
ASSEMBLY KIT:SEALS (VITON) AND SCREWS
CONVERSION PLATE
MDM-5
Single Type
Dual Type
19(0.75)
5(0.2)
9,5(0.37)
9,5(0.37)
A,B,P: 5(0.2)
T: 4(0.16)
17(0.67) 17(0.67)
13(0.51)
23(0.91) 23(0.91)
23(0.91)
23(0.91)
5(0.2)
8(0.32)
17(0.67) 17(0.67)
13(0.51)
13 (0.51)
9,5(0.37)
B,P: 5(0.2)
T: 4(0.16)
30 (1.18)
30 (1.18)
30 (1.18)
13 (0.51)
8(0.32)
30 (1.18)
19(0.75)
187(7.36)
133,5(5.26)
63,5(2.5)
63,5(2.5)
10(0.39)
60(2.36)
63,5(2.5)
60(2.36)
9,4(0.37)
88(3.46)
solenoid a
33(1.30)
56(2.20)
solenoid b
33(1.30)
56(2.20)
solenoid b
33(1.30)
33(1.30)
88(3.46)
9,4(0.37)
5,4(0.21)
6 Nm (4.4 lb ft): 4 x M5
5,4(0.21)
SUBPLATE: A-5-DM
M6 (4x or 6x), 9 (0.35) dp.
25(0.98)
11(0.43)
A2
A3
A4
A5
A6
B1
B2
B3
B4
B5
B6
23(0.9)
A1
T
27,5(1.08)
48(1.89)
48(1.89)
48(1.89)
48(1.89)
48(1.89)
40(1.57)
18,5(0.73)
12(0.47)
23(0.91)
25(0.98)
18,5(0.73)
25(0.98)
c
12,5(0.49)
60(2.36)
30(1.18)
22(0.87)
a
8(0.32)
4,5(0.18)
4,5(0.18)
11(0.43)
30(1.18)
11(0.43)
8(0.31)
a
A-5-DM-1:
A-5-DM-2:
A-5-DM-3:
A-5-DM-4:
A-5-DM-5:
A-5-DM-6:
80(3.14)
128(5.04)
176(6.96)
224(8.82)
272(10.71)
320(12.6)
b
30 (1,18)
78 (3,07)
126 (4.96)
174 (6.85)
222 (8.74)
270 (10.63)
c
126 (4.96)
126 (4.96)
49(1.93)
21(0.83)
65(2.56)
5,4(0.21)
9(0.35)
28(1.10)
MAINTENANCE DATA
Mounting procedure
- AMCA-valves shall not be mounted by
overtightening of mounting bolts, causing
mechanical distortion and thus spool lock.
- Mounting on flat surface, flatness 0,01/100.
- Dont use conical thread for port-fittings.
- For sealing purposes, use O-rings.
- Check the voltage andcurrent of the solenoids,
before operation.
- Avoid ingression of contaminants during
mounting.
Start-up procedure
- Check the valve-function and thetightness of
fittings etc.
- Bleed by repeated energizing of solenoid(s).
- Run the system to raise the fluid temperature.
Rebleed to remove the dissolved air.
Adjustment procedure
Valve response time:
The valve response time isadjustable from
0,08 - 10 seconds.
Adjustment screws (damping throttles) are on the
MDM-5 valve below the solenoids , fig 12 (1).
- Turn the adjustment screws clockwise to enlarge
valve response time.
- Turn the adjustment screws anti-clockwise to
shorten valve response time.
Fluid maintenance
Due to the construction, these AMCA-valves, are
not highly susceptible to particulate (silt type)
lock, nor to contaminant wear. Therefore the
contaminant sensitivity is very low.
- Use mineral oil (recommended ISO/VG-32).
Other fluids on request.
- Keep the contamination level better or equal NAS
1638 class 9 or ISO 18/15.
TROUBLE SHOOTING
1) Damping throttle
2) Spool
3) Pistons
FIG. 12
3) Spool, pistons or solenoids are dirty: Remove
A. Valve operates erratically
1) Check the current on the solenoid plug.
solenoids or cover and clean solenoids bore and
2) Air in system: Bleed by repeated energizing of
spool (take care of the small pistons (3) in the
solenoid(s). Run the system to raise the fluid
spool (2) if placed, see fig.12).
temperature. Rebleed to remove the dissolved air.
3) Check the resistance of the solenoid coil:
C. System is too slow
- 24 VDC at 20 o C (68 o F) = 25 Ohm,
1) Damping throttles are closed too much: open up
at 60 o C (140 o F) = 30 Ohm
the throttles.
- 12 VDC at 20 o C (68 o F) = 6,5 Ohm,
2) Electrical fault (ramp generator): check and reset.
at 60 o C (140 o F) = 7,5 Ohm
3) Damping throttle or spool are dirty: Remove the
parts, 1, 2 and 3, clean everything and replace.
B. Max. reducing pressure too low
1) Maximum current is faulty: check max. current.
2) Supply pressure is too low: Check system
pressure.