Sunteți pe pagina 1din 2

Boiler Controls

Low Water Cut-Offs Mechanical


Combination Low Water Cut-Off/Pump Controllers for Steam Boilers
Series 193
Low Water Cut-Off/Pump Controllers

For commercial and industrial low or


high pressure steam boilers
Maintains consistent water level
regardless of pressure
Water column with integral tappings for
gauge glass and tri-cock installations
For boilers of any steaming capacity
No. 5 Switch included
Magnetic repulsion eliminates need for
bellows
Optional features
Manual reset
7B switch (135ohm proportional control
signal) to maintain constant boiler water
level
1" NPT connections
Maximum pressure 150 psi (10.5 kg/cm2)

X
A

CUT-OFF
LEVEL

E
G

F
H

SERIES 193

Ordering Information

Electrical Ratings

Dimensions, in. (mm)


B
NPT

C
NPT

D
NPT

Model
Number

Part
Number

193

163400

193-A
193-A-7B
193-A-7BM
193-A-M
193-B
193-B-M
193-B-7B
193-D
193-D-7B
193-M
193-7B
193-7BM
193-D-M
193-G

163500
164500
164600
164200
163600
164300
164700
163900
163903
164100
164400
164525
163902
164760

Weight
lbs. (kg)

Description
Combination low water cut-off/
pump controller w/No. 5 switch
193 w/alternate tappings
193-A w/No. 7B switch
193-A-7B w/manual reset
193-A w/manual reset
193 w/alternate tappings
193-B w/manual reset
193-B w/No. 7B switch
193 w/alternate tappings
193-D w/No. 7B switch
193 w/manual reset
193 w/No. 7B switch
193-7B w/manual reset
193-D w/manual reset
193 w/alternate tappings

193
193-A
193-B
193-D
193-G
Model
193
193-A
193-B
193-D
193-G

L
1234 (324)

3
12 4 (324)

1112 (292)

1112 (292)
1112 (292)

N
101316 (274)
101316 (274)
101316 (274)
101316 (274)
101316 (274)

P
13 (330)
13 (330)
13 (330)
13 (330)
13 (330)

214 (57)

214 (57)
214 (57)

R
278 (73)

7
2 8 (73)

Model
193
193-A
193-B
193-D
193-G

S
634 (171.4)
634 (171.4)
634 (171.4)
634 (171.4)
634 (171.4)

T
1712 (445)
1712 (445)
1712 (445)
1712 (445)
1712 (445)

U
2012 (521)
2012 (521)
2012 (521)
2012 (521)
2012 (521)

V
312 (89)
312 (89)
312 (89)
312 (89)
312 (89)

W
312 (89)
312 (89)
312 (89)
312 (89)
312 (89)

X
6 (152)
6 (152)
6 (152)
6 (152)
6 (152)

2
2
3
4
1

2
2
3
4
1
2
1
2
1

F
NPT

1
1

2
2
2

G
NPT
1

2
4

H
NPT
1

2
4

J
NPT

52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)
52.5 (23.8)

A
NPT
1
1
114
1
1

2
2
3
4
1
2
1
2

E
NPT

52.5 (23.8)

K
NPT

2
2
1
2
1
2
1
2

4
4
3
4
3
4
3
4

49

Boiler Controls

CUT-OFF LEVEL
150

345 VA at 120 or 240 VAC

Model

Boiler Controls
Low Water Cut-Offs Mechanical
Combination Low Water Cut-Off/Pump Controllers for Steam Boilers
Series 194
Low Water Cut-Off/Pump Controllers

For commercial, and industrial low or high pressure


steam boilers

Maintains consistent water level regardless of pressure

J
C

For boilers of any steaming capacity

U
V

Water column with integral tappings for gauge glass and


tri-cock installations

M
L

W
T

No. 5 Switch included

CUT-OFF
LEVEL

Boiler Controls

CUT-OFF LEVEL
250

R
S

Magnetic repulsion eliminates need for bellows

Optional features
Manual reset
7B switch proportional 0-135 ohm control to maintain
constant boiler water level

SERIES 194

114" NPT connections

Ordering Information

Maximum pressure 250 psi (17.6 kg/cm )


2

Ten bolt flange

Electrical Ratings
345 VA at 120 or 240 VAC

Model
Number

Part
Number

194

166600

194-A
194-A-7B
194-M
194-7B
194-7BM
194-B

166700
167100
166900
167200
167300
166701

Weight
lbs. (kg)

Description
Combination low water cut-off/
pump controller w/Series 5 switch
194 w/alternate tappings
194-A w/Series 7B switch
194 w/manual reset
194 w/Series 7B switch
194-7B w/manual reset
194 w/alternate tappings

72.0 (32.7)
72.0 (32.7)
72.0 (32.7)
72.0 (32.7)
72.0 (32.7)
72.0 (32.7)
72.0 (32.7

Dimensions, in. (mm)


Model
194

A
NPT
114

B
NPT
1

1 4

194-B

1 4

Model

F
NPT

G
NPT

2
4

2
1
2
1
2

4
4
3
4
3

2 16 (71)

2 8 (60)

1 4 (32)

12 8 (327)

6 4 (171.4)

13 16 (332)

2 16 (71)

1 4 (32)

238 (60)

194-B

1278 (327)

634 (171.4)

13116 (332)

21316 (71)

114 (32)

238 (60)

194

T
1

17 4 (438)
1

13

194-A

Model

K
NPT

2
4

13

13 16 (332)

J
NPT

6 4 (171.4)

H
NPT

11 8 (295)

2
1
2
3
4

M
5

E
NPT

2
1
2
3
4

194

D
NPT

2
1
2
3
4

194-A

C
NPT

3 (76)

3 (76)

6 (152)

10 16 (274)

20 2 (521)

13

194-A

17 4 (438)

20 2 (521)

3 (76)

3 (76)

6 (152)

101316 (274)

194-B

1714 (438)

2012 (521)

3 (76)

3 (76)

6 (152)

101316 (274)
51

S-ar putea să vă placă și