Documente Academic
Documente Profesional
Documente Cultură
1 Contents
=======================================================================
Table of Contents
A) Hardware Diagnostics
B) Post-Install OS scripts
C) Microsoft Windows Driver Installation
D) Microsoft Windows RIS Installation
E) Microsoft Windows 2003 Reburn Installation
F) RAID Controller Management Software Installation
G) History
=======================================================================
A) Hardware Diagnostics
The Hardware Diagnostics is a DOS based test suite. To run,
leave the Tools & Driver DVD in the cdrom tray and reboot the system.
At the Tools & Driver DVD Main Menu enter '1' to start the Hardware
Diagnostic Test Suite. The test suite comes with a complete set
of test scripts that can configure the system automatically. Read
the README file found in the \diags directory to retrieve a complete
listing of all the scripts. To access this directory type the
following command at the DOS prompt.
cd diags
=======================================================================
B) Post-Install OS scripts
The Post-Install OS scripts can be found at the following directories:
/drivers/linux/red_hat/install.sh = Red Hat 32bit and 64bit installation.
/drivers/linux/suse/install.sh = SLES 10 for 64bit
/drivers/sx86/install.sh = Solaris X86 installation.
These scripts should be run after the installation of the OS is
completed. The scripts will install the following:
/drivers/linux/red_hat/install.sh
1) Mounts Diagnostic Partition if one is present.
2) Installs Intel NIC drivers.
3) Installs AST2000 VGA driver.
/drivers/linux/suse/install.sh
1) Mounts Diagnostic Partition if one is present.
2) Installs AST2000 VGA driver.
/drivers/sx86/install.sh
1) Mounts Diagnostic Partition if one is present.
2) Installs AST2000 VGA driver for Solaris 10 Update 1, 2 and 4.
=======================================================================
C) Microsoft Windows Driver Installation
The Microsoft Windows drivers can be installed using the Autorun menu.
This menu will be displayed when the Tools & Drivers DVD is inserted into
your Sun Fire X4150/X4250 Server.
Drivers installed, include, the Intel Chipset, Intel Ethernet,
AST2000 VGA driver and the Infineon TPM Security driver.
To manually install any of these drivers, please access the drivers
directory on the DVD.
=======================================================================
D) Microsoft Windows RIS Installation
The directions for installing Microsoft Windows via RIS (Remote Installation
Service) can be found at the following directory:
\drivers\windows\IntelNIC\RIS\README.TXT
=======================================================================
E) Microsoft Windows 2003 Reburn Instructions
The directions for creating a modified Microsoft Windows 2003 32/64
distribution CD can be found at the following directory:
\utilities\reburn\readme.txt
This details how you can generate a modified distribution bootable
iso image either from a linux (RedHat, SuSE or Solaris) or a windows OS.
=======================================================================
F) RAID Controller Management Software Installation
The directions for installing the RAID Controller Management Software can be
found in the following directories:
Linux Installations:
\RAIDmgmt\LSI\linux\MSM - README.TXT
\RAIDmgmt\StorageTEK\linux\ASM - README.TXT
Solaris Installations:
\drivers\sx86\RAID - README.TXT
Windows Installations:
\drivers\windows\RAID - README.TXT
=======================================================================
G) History
--------------------Update in SW 3.1.1
--------------------1) BIOS is updated to 1ADQW065 for bug fixes:
- 6905018: System Serial Number show "To Be Filled By OEM"
2) SP is updated to ILOM 3.0.6.15 build r50607
- Bundle BIOS 065
--------------------Update in SW 3.1.0
--------------------1) BIOS is updated to 1ADQW063 for bug fixes:
- 6881539 Not disable DIMM for any CE error found during Memory Initializatio
n
- 6902797 Change Memory Scrub Failed to uncorrectable error or correctable er
ror
2) SP update to 3.0.6.15 build r49314:
- New features:
* Power Management, please refer to "Sun Integrated Lights Out Manager (ILO
M) 3.0 Feature Updates and Release Notes" in http://docs.sun.com/app/docs/coll/i
lom3.0
- Bug Fixes
* 6810948: green led does not blink while SP boots and SYS posts
* 6862498: Add virtual DIMM presence sensors