Sunteți pe pagina 1din 13

ZXDU48 H002(V5.

0) Outdoor
Wall-mounted DC power System
H7+F.4.5kW.220P1.C.LB.10011
Product Description

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011


Product Description

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power


System H7+F.4.5kW.220P1.C.LB.10011 Product
Description
Version
V1.0

Date
2014/04/04

Author
Zhang Lei

Reviewer

Notes

Wei Shuwang

2014 ZTE Corporation. All rights reserved.


ZTE CONFIDENTIAL: This document contains proprietary information of ZTE and is not to be disclosed or used
without the prior written permission of ZTE.
Due to update and improvement of ZTE products and technologies, information in this document is subjected to
change without notice.

ZTE Confidential Proprietary

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011Product


Description

TABLE OF CONTENTS

1
1.1
1.2

Product overview ...............................................................................................4


General introduction .............................................................................................4
Product version .....................................................................................................4

2
2.1
2.2

Product highlight ...............................................................................................4


A wide range of input voltage ................................................................................4
Capacity expansion ..............................................................................................4

3
3.1
3.2

Product configuration ........................................................................................5


Unit configuration ..................................................................................................5
Basic function module ...........................................................................................5

4
4.1
4.2
4.3

Product technical description ...........................................................................6


Product pictures....................................................................................................6
System technical specification ..............................................................................6
Unit technical specification..................................................................................10

Solution and application ..................................................................................10

Abbreviation .....................................................................................................10

ZTE Confidential Proprietary

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011


Product Description

FIGURES
Figure 4-1 Outline drawing................................................................................................... 6
Figure 4-2

Distribution unit drawing ................................................................................... 10

TABLES
Table 3-1 Unit configuration table ........................................................................................ 5
Table 3-2 Function module configuration table .................................................................... 5
Table 4-1 System technical specification ............................................................................. 6
Table 6-1 Abbreviation....................................................................................................... 10

ZTE Confidential Proprietary

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011Product


Description

Product overview

1.1

General introduction

This power supply system is an outdoor DC power system.

This power supply system is pole-mounted.

This power supply system can provides -53.5VDC power for communications
equipment.

In full configuration, this power supply system can be equipped with three
ZXD1500(V5.0) rectifiers, which form a rated output power of 4.5kW (-48V to
-57.6V).

1.2

Product version

V5.0

Product highlight

2.1

A wide range of input voltage

A wide range of input phase voltage (85V to 295V) makes the system suitable for
areas with unstable sources.

2.2

Capacity expansion

The system can be equipped with one to three ZXD1500(V5.0) according to the load
power.

ZTE Confidential Proprietary

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011


Product Description

Product configuration

3.1

Unit configuration
Table 3-1 Unit configuration table
Item

Description

ZXDU48 H002V5.0

600mm in width, 500mm in

outdoor wall-mounted

depth,1000mm in height.

DC power supply

Equipment cabin with 400W

system

heat-exchanger.

H7.4.5kW.220P1.C.L

Optional: A socket with a

B.10011

MCB(1P), DC lighting.

Note

Free space: 6U.

DC power supply subrack:


19inch in width, 5U in height.
AC input: single-phase
three-wire,220V,(L/N/PE).
AC SPD: Class C.
Low voltage disconnect:
LLVD,BLVD.
Battery MCBs: 100A/1P*1.
DC output MCBs: 9Pfull
configuration.
DC SPD: 15kA.

3.2

Basic function module


Table 3-2 Function module configuration table
Item

Description

Note

ZXD1500(V5.0)Rectifier Module

Rectifier module

optional

CSU520B Monitoring Unit

Supervision module

1set

ZTE Confidential Proprietary

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011Product


Description

Item

Description

Note

DC output MCBs

optional

ZXDUPA-WR05V1.0R09M01

optional

outdoor cabinet pole-mounted


assembly
ZXDUPA-WR05V1.0R09M01

optional

outdoor cabinet floor-mounted


assembly

Product technical description

4.1

Product pictures
Figure 4-1 Outline drawing

4.2

System technical specification


Table 4-1 System technical specification
Classification
System
information

Item

Description

Product type

ZXDU48 H002V5.0

Rectifier module

ZXD1500V5.0

Supervision module

CSU520B

ZTE Confidential Proprietary

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011


Product Description

Classification

Item

Description

Input type

single -phase three-wire(L /N/PE)

Rated input voltage

220V240V(phase voltage)
Phase voltage:85V295V

Input voltage range ( including

When the input voltage is 85V to

the derating description)

176V, the output power is not the


highest percentage (100%).

AC distribution

Input frequency range

45Hz66Hz

Maximum input current

42A

Input PF( 30% load)

0.97

Input PF( 50% load)

0.99

Input PF( 100% load)

0.995

THDI ( 30% load)

7%

THDI ( 50% load)

7%

THDI ( 100% load)

3%

Input main protection( Circuit


breaker or fuse)

Circuit breaker

Input connecting type


( Example: line terminal
connecting)
Input protection for every rectifier
module
AC backup output

AC lightning protection

A socket controlled by a 16A/1P


MCB.
Class C,
Imax=40kA.

Rated output voltage

-53.5V

Output voltage range

-42V~ -58V

Maximum output current

90A

DC

Maximum output power

4.5kWin full configuration

distribution

Source effect
Load effect

ZTE Confidential Proprietary

Voltage stabilizing accuracy

0.6%

System efficiency ( 30% load)

93.5%

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011Product


Description

Classification

Item

Description

System efficiency ( 50% load)

95.5%

System efficiency ( 100% load)

94.5%

Output weighted noise voltage

2mV

Output peak-peak noise voltage

200 mV 0Hz~20MHz

Broad frequency noise voltage


Discrete frequency noise voltage
Internal voltage drop

500mV

Current unbalance (Current


share
Load distribution

9P MCBs (in full configuration).

Battery distribution

1100A/1P(MCB).

DC lightning protection

Imax=15kA8/20s.

AC OVP

286V

AC OVP recovering
AC UVP
AC UVP recovering

AC OVPreturn difference.
Return difference ranges 10V.
154V
AC UVPreturn difference.
Return difference ranges 10V.

DC OVP

58V.

DC OVP recovering

0.5V.

DC UVP

48V.

DC UVP recovering

0.5V.

Battery UVP

48V.

AC voltage detecting accuracy

1%

Alarm and
supervision

Battery and output current


detecting accuracy
Battery and output voltage
detecting accuracy

1%
0.5%

Temperature detecting accuracy

3%

Humidity detecting accuracy

5%

Switching detecting accuracy


Mechanical

Equipment dimension

600mm in width, 500mm in

ZTE Confidential Proprietary

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011


Product Description

Classification

Item

parameters

Description
depth, 1000mm in height.

Package dimension
Equipment weight

Approximately 85 kg(excluding
rectifiers, CSU, SIU).

Package weight
SIU weight
CSU weight
rectifier module weight

1.6kg/set

Cabinet color (PANTONE color

PANTONECOOL GRAY 2C

with color number)

RAL7035

Operating noise

63dB(A)
Input & output relays, RJ45 Ethernet

Monitoring network interface

Others

interface, RS232 interface, and


RS485 interface.

MTBF

2*105h

Design life

10 years

Operation temperature ( including


temperature derating)
Storage temperature
Relative humidity

-20 ~ +50
-40 ~ +70
10% to 90%non-condensing.
40% to 60% recommended

Environment

78kPa~101kPa

Air pressure ( and altitude


derating)

0 to 2000m:100% output power


2000m to 3000m: The power
derating percentage is 1% when the
altitude increases by 100m.

Safety

In compliance with IEC60950.

EMI

In compliance with IEC61000.

Shaking

In compliance with YD5083 and


YD5096.

Relative
standard

ZTE Confidential Proprietary

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011Product


Description

4.3

Unit technical specification


Figure 4-2 Distribution unit drawing

Solution and application

Abbreviation
Table 6-1 Abbreviation
Abbreviatio

10

Full name

AC

Alternating Current

BHTD

Battery high temperature disconnect

BLVD

Battery low voltage disconnect

CAN

Controller area network

CSU

Centralized supervision unit

DC

Direct Current

EMC

Electromagnetic compatibility

EMI

Electromagnetic interference

FTP

File transfer protocol

GND

Ground

HTTP

Hypertext transfer protocol

LLVD

load low voltage disconnect

MTBF

Mean time between failures

ZTE Confidential Proprietary

ZXDU48 H002(V5.0) Outdoor Wall-mounted DC power SystemH7+F.4.5kW.220P1.C.LB.10011


Product Description

NE

Network element

PE

Protective earth

RoHS

Restriction of hazardous substance

SIB

Signal interface board

SIU

Signal interface unit

SNMP

Simple network management protocol

SPD

Surge protection device

THD

Total harmonic distortion

USB

Universal serial bus

ZTE Confidential Proprietary

11

S-ar putea să vă placă și