Sunteți pe pagina 1din 4

TRANSPORTABLE

DTECTEUR DE STAND
GAZ
ALONE MULTIGAS DETECTOR

BM22 PLUS

Simultaneous measurement
of up to 4 gases

Smart precalibrated
interchangeable
sensor modules

Data/events logging

Long battery life


> 150 hours

Rugged,
high visibility beacon and
audible alarm (105 db)

Your environment, your safety,


lets master them together

Safety in the field

Example : protection within your work area

The BM22 PLUS has been specially designed for operation in harsh environments.
The BM22 PLUS is compact, rugged, equipped with a
large flashing beacon, a loud audible alarm and has a
long battery life.
The BM22 PLUS is designed for team protection or
area surveillance. It can be equipped with an integral
pump.
The BM22 PLUS is most suitable for rescue teams, for
mobile or short term works, and areas where fixed
detection systems are inapropriate or not present.

A long battery life for higher safety


High performance
The BM22 PLUS can detect simultaneously from 1 to 4 gases.
A library of 32 flammable gases are built into its memory and can be selected without having to recalibrate the
instrument. The oxygen and toxic sensor modules are precalibrated, smart and interchangeable.

Ease of use
Reliable, safe and user friendly, the BM22 PLUS initiates an auto-test procedure when switched on. Intemal fault
finding and self diagnostics make the BM22 PLUS a unique instrument.

Robust
The casing is made of hard thermo-polyester with carbon fibre rendering the BM22 PLUS suitable for harsh and
corrosive environments.

Handy device
The BM22 PLUS may be used as a compact stand alone
instrument or can be interlinked to a central alarm unit
the AC 22 Central Guard (max up to 4 BM22 PLUS).
A relay contact is built in to drive external devices. Equipped
with a flashing red beacon (5 joules) and loud hooter (105 db)
it can be heard in a noisy environment.
It has 150 hours battery life.
The battery pack can be replaced in classified area.
It is intrinsically safe.

Carrying handle

Flashing red beacon

Audible alarm

Data logging
The BM22 PLUS can log up to 48 hours of data and 252 events.
This information can be down loaded on to a printer or to a P.C.
Maintenance and operation software is also available.

Sensors

Relay output
On / Off switch

Programming,
alarm acknowledgement,
display back light... buttons

Alarm LED
LCD display
Battery pack

Sensor modules specifications


Detected gas
Explo
O2
CO
H2S
SO2
NO
NO2
Cl2
HCl
HCN
NH3
H2
ETO
VCM
ASH3
SIH4
COCl2
N2H4
O3
HF
ClO2
C6H5CH3
PH3
VOC

Standard range (1)


100 % LIE
0-30 % vol/5-30 % vol
1000
100
30,0
300
30,0
10,0
30,0
30,0
100
1000
2000
30,0
200
1,00
50
1,00
1,00
1,00
10,00
3,00
1000
1,00
500

CO2

5,0 % vol

CAT

CH4 100 % vol

Resolution (2)
1 LIE or 3 %
from 5 to 30 % = 0, 3 % vol
from 0 to 5 % = 0, 5 % vol
5 ppm or 4 %
5 ppm or 4 %
1 ppm or 4 %
5 ppm or 4 %
1,5 ppm
0,5 ppm or 5 %
1 ppm or 5 %
1 ppm or 5 %
7 ppm or 10 %
25 ppm or 4 %
30 ppm or 4 %
1,5 ppm
5 ppm or 10 %
0,05 ppm or 10 %
4 ppm
0,05 ppm or 10 %
0,1 ppm or 10 %
0,05 ppm or 10 %
1 ppm or 20 %
0,2 ppm or 10 %
+ /- 30 ppm
0,05 ppm or 10 %
from 0 to 100 = 10ppm
from 100 to 500 = 20 %
from 0 to 1,5 % vol = 0,1
from 1,5 % to 5 % vol = 10 %
1 % vol or 4 %

Accuracy (3)*
1 LIE
0, 10 %
0, 10 %
1
1
2
2
2
2
3
3
5
5
2
2
3
3
3
5
5
5
5
2
3
5
5
5
2
2
1 % vol

Zero drift (4)


0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
3
3
2
2
2
1
5
4
2
2
2
2
2
2
0,5
2
2
2
2
1
1
0,5

T50 (5)
5
10
10
15
15
15
15
20
50
50
30
50
50
50
50
70
70
40
50
60
40
50
50
50
40
30
30
12
12
60

(1) in ppm except explo, CO2, CAT et O2

(3)* in % of the signal- FDS : Full Scale Deflection

(6) in C

(2) fixed value or % of the signal (at 20 C)


take the higher value

(4) per month in % of the scale

(7) average during the month

(5) in second at 50 % of the value

(8) in months garanty by manufacturer

T(6)
-30 +75
-20 +40
-20 +40
-20 +40
-20 +50
-10 +50
-20 +50
-20 +50
-20 +50
-20 +40
-20 +40
-20 +40
-20 +40
-20 +50
-20 +50
-10 +40
-10 +40
-20 +40
-10 +40
-10 +40
-10 +40
-10 +30
-20 +50
-20 +50
-20 +40
-20 +50
-10 +50
-10 +40
-10 +40
-10 +40

Accessories
Central guard type AC22
Up to 4 BM22 PLUS can be interlinked to a central
alarm unit type AC22.
The Central Guard is equipped with 4 on/off LEDs,
4 gas alarm LEDs and a relay.
The battery pack, the visual and audible alarms
are identical to the BM22 PLUS.
Wall type battery charger :
- 220 or 110 V AC
- regulated charger
- charges a BM22 PLUS or a battery pack
Battery pack
Calibration kit
Manual sampling kit
Integral electric sampling pump

Data can be downloaded on printer or through a computer

Life span (7)


60
28
28
36
36
36
36
24
24
24
24
24
24
24
36
24
24
18
18
24
18
18
24
24
18
60
60
60
60
60

Warranty (8)
12
12
12
12
12
12
12
12
24
24
24
24
24
24
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

Manufacturer :
Function :
Type :
Configuration :

Measurement :
Sampling (option) :

Sensor :

Display :

Change over :

Sensor fault :

Operational management :
Visual alarms :

Audible alarm :

OLDHAM SA
Transportable stand
alone multigas monitor
Multiguard BM22
Up to four gases selected
from
- One flamable gas
(selected from table of
32 preprogrammed
gases)
- Three sensors of your
choice (see table of
oxygen and toxic
sensors)
Continuous
Manual pump or
electrical I.S. integral
pump
Interchangeable
precalibrated smart
sensor modules
Automatic recognition of
sensor type by
instrument
2 lines of 16 characters in
LCD
Back light
Automatic change of
scale from LEL to volume
in % in case flammable
gas should exceed the
LEL
Continuous audible and
visual alarms.
Message displayed
Auto-test function on
start up
For methane only - yellow
LED indicates change
from LEL to Vol%
4 gas and fault LEDs
1 common flashing light :
5 joules
105 db at 1 m
Built-in static relay

Alarms :

Output :

Power supply :

Operating time :
Recharging time :
Certification :
Protection rating :
Weight :
Dimension :
Non ambiguity reading :

1 instantaneous
threshold for flammable
channel
2 instantaneous
thresholds for oxygen
channel
For toxic channel :
- instantaneous alarm
- 1 STEL alarm
- 1 TWA alarm
Direct to a printer
To a PC for maintenance
and logging of
information
Interchangeable battery
pack can be changed in
hazardous area
150 hours battery life
8 hours (full charge)
EEx ia d IIC T4
IP65
7 kg
H 425 x W 160 x D 130 mm
LED display and detector
shows overange for
flammable gas

490
425

130

Plant and head office : Z.I. Est - rue Orfila


B.P. 417 - 62 027 ARRAS Cedex FRANCE
Tel. : 33 3 21 60 80 60 Fax : 33 3 21 60 80 06
Web site : http://www.oldham.fr

Your agent or retailer

OLDHAM

160

This is not a contractually binding document. OLDHAM SA reserves the right to make any changes, without notice, to the technical characteristics of its equipement. Designed and created by Audace 33 3 21 135 600. Edition ref.: BM22PLUSGB02

TECHNICAL SPECIFICATIONS

S-ar putea să vă placă și