Documente Academic
Documente Profesional
Documente Cultură
Contract:
Subtitle:
INDRA
Name
Signature
Date
Responsability
Prepared
09/07/2012
System Engineering
Revised
09/07/2012
System Engineering
Approved
Domingo Olivares
09/07/2012
Technical Manager
Authorized
Francisco J. Zapata
09/07/2012
Product Manager
Indra owns the copyright of this document, which is supplied confidentially and must not be used for any purpose other than
that for which it is supplied. It must not be reproduced either wholly or partially, copied or transmitted to any person without
the authorization of Indra
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 1
Page 1 of 6
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Edit./Rev.
Chapter
Edit./Rev.
i-vi
A/0
A/0
A/0
A/0
A/0
A/0
A/0
A/0
Chapter
Edit./Rev.
Chapter
Edit./Rev.
Date
Chapters
A/0
09/07/2012
1-10
New Document
DISTRIBUTION SHEET
Copy N.
Chapter 1
Page 2 of 6
Company / Organization
Department
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
TABLE OF CONTENTS
Chapter
3.1
Description
Page
STORAGE ...................................................................................................................................1
3.1.1
3.1.2
4.1
4.2
4.2.1
4.2.2
4.3
4.3.1
REC ........................................................................................................................................6
4.3.2
CONTENTS ............................................................................................................................7
4.3.3
FORMAT ................................................................................................................................7
4.3.4
EJECT ....................................................................................................................................7
4.4
4.5
4.6
4.6.1
Introduction ...........................................................................................................................8
4.6.2
4.6.2.1
Commands Area..............................................................................................................11
4.6.2.1.1
CONTENTS................................................................................................................12
4.6.2.1.2
LOAD ..........................................................................................................................12
4.6.2.1.3
4.6.2.1.4
4.6.2.1.5
FILTER .......................................................................................................................13
4.6.2.2
4.6.2.3
4.6.2.4
4.6.3
4.6.3.1
4.6.3.2
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 1
Page 3 of 6
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
TABLE OF CONTENTS
Chapter
4.6.4
Description
Page
5.1
5.2
5.3
5.3.1
5.3.2
5.3.3
5.4
5.5
5.6
5.7
5.7.1
5.8
6.1
6.2
6.2.1
6.2.2
6.3
6.3.1
6.3.2
6.3.3
Two tapes with data and the tape 2 in recording status ..................................................6
7.1.1
7.1.2
7.1.3
7.1.3.1
Eject ...................................................................................................................................3
7.1.3.2
Format ...............................................................................................................................3
Chapter 1
Page 4 of 6
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
FIGURES INDEX
Description
Page
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 1
Page 5 of 6
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
FIGURES INDEX
Description
Page
TABLES INDEX
Description
Page
Chapter 1
Page 6 of 6
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
1. INTRODUCTION
The Data Recording and Playback Position (DRF) is one of the elements of the Tower and Approach
Integrated Control System.
The main duties of this position are the recording of all relevant data in a convenient order and their
subsequent recognition and playback.
The DRFs is a utility for recording and playbacking. The information of SDDs is saved on tapes.
The process is:
1. SDDs record all data in local files. The data are: Events, monitoring, etc. This data files are sent
to the DRFs each hour automatically.
2. When the DRFs receive the files from the SDDs, these ones are recorded on tapes.
3. The DRFs displays to technical staff all files received from the SDDs on a screen as well all files
save on tapes.
Also, the DRFs allow monitoring the tapes states, the recorder files, used capacity tapes.
To reproduce information stored in tape it would be enough with:
1st: To gather the necessary files stored in tape. This operation is carried out by means of an
intuitive graphic interface.
2nd: The DRF will take charge loading the above mentioned information in the SDD specified by
the technician for his later reproduction.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 1
Page 1 of 4
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Chapter 1
Page 2 of 4
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
2.
REFERENCE DOCUMENTS
N/A
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 2
Page 3 of 4
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Chapter 2
Page 4 of 4
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
3.
PLAYBACK
In the AIRCON 2100 System exist two clear ways to playback one SDD:
1st: PLAYBACK 24h:
This one play all data stored in one SDD.
This data stored is, only, the last 24 hours.
Allow playback more quickly because the recorded data are stored in the same SDD.
Only is possible playback in the same SDD that success occurs because the data are stored in
the same SDD.
2nd: PLAYBACK:
Allow this playback it is possible play all success or event stored in tape.
It is possible to specify a SDD to reproduce the events.
It is possible to reproduce the events stored of a SDD in another different SDD.
To reproduce in this mode is necessary load data from a tape. Obviously, this load process isnt a
real time process. It is necessary to wait the all requested data loading.
3.1
STORAGE
In accordance with the playback modes, the system offers two storage modes:
3.1.1
Local Storage
Each control position carries out its recording using its own local disc. These recordings concern received
data, local configurations (maps, etc.) and the most relevant actions achieved by the controller (for
example: Hand-over actions).
General system information: Messages received at control positions (radar targets, radar/ADS tracks sent
by the SDP, flight sent by the FDP, etc.). This information is recorded making use of compressed files
with one hour capacity.
Each SDD records during a maximum of 24 hours and when one hour file is complete, the system copy
this file in the DRFs and the oldest file is removed immediately.
All SDDs send every hour automatically the last generated files to the DRFs.
When the xx % (defined in a configurable file) capacity of local hard disk is exceeded, the supervisor
position is warned about it.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 3
Page 1 of 2
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
3.1.2
Central Storage
Recording files on disc. The information kept in these files is local information concerning every
single
control
position.
This
files
are
stored
in
local/<proj>/sdd/exec/grabacion/pregrabados folder waiting to transfer at tapes by
the DRFs.
The list of files pending to transfer to the tapes are stored in ASCII file named "pendientes"
existing in local/<proj>/sdd/exec/grabacion/pregrabados
Data transfer from disc to tape. The information received from SDDs will be saved on tapes by
DRFs. The DRFs between 5 and 10 minutes test if they are files on a
local/<proj>/sdd/exec/grabacion/pregrabados folder to transfer at tapes.
This Recording function is able to keep 9000 files capacity tapes (approximately depending on the SDDs
activities). This offers a convenient interval of time in case of tape unavailability.
Chapter 3
Page 2 of 2
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
4.
Commands Area.
It is located at the top of the main screen and allows the display of the tape recording/playback
windows.
The colour of the icon informs about the tape use:
Information Area.
It offers information about recording/playback on every tape.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 1 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
4.1
This area informs about the position name, date and current time.
Chapter 4
Page 2 of 22
Description
HH: MM: SS (HH = Hour, MM = Minutes, SS = Seconds)
DD/MM (DD = Day, MM = Month)
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
4.2
TAPE STATUS
This area is located at the top of the DRF screen. It shows four icons: TAPE 1, TAPE 2, Tape1 Change
status and Tape2 Change status.
So, as before the colour of the icons informs about the tape functionality (described in the last point).
4.2.1
The changes concerning the tape status is performed at the DRF position when the technical push on the
next Tape Status 1 or Tape Status 2 icons:
(The tape status is modified directly by pressing on one of these icons)
Accepting window the system change the tape operative. In the change process all functions are disabled
for a few minutes. After process the DRF come back to operative status and continues recording since
the last file processed.
This operation is confirmed and the next window represents the changing status with the all functions
disabled (Clear Grey).
IMPORTANT: When the tape status is changed, the new tape that the state is recording MUST BE
FORMATTED. All data in new recording tape will be erased.
When the change process is finished the Tape status is changed.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 3 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
On Tape1, the old content will be kept, while the Tape2 will be formatted. If we want to keep the old
content on Tape2 too, the small slot on the should be opened.
Chapter 4
Page 4 of 22
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
4.2.2
Auxiliary window shows all information about files pending to copy in the tape and the files
contents in the tape.
Auxiliary window shows information about files stored in the tape and the options to charge
data to playback in one SDD.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 5 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
4.3
Description
REC
CONTENTS
FORMAT
EJECT
CANCEL
4.3.1
REC
This immediate recording should be exclusively used when an incident occurs on any control position.
By pressing the [REC] icon, all accumulated data on the SDDs and all common data on the DRF are
recorded on the tape; the recorded files will be visualized at the Area of Recorded Files.
When [REC] is pressed, in CMD appears one System message: DRFx QUICKLY REC
When the recording on tape cannot be performed, the files will be saved on the disc pertaining to the DRF
and displayed on the Area of Files Pending of being Recorded.
This icon will remain inhibited until the recording process is not finished.
Chapter 4
Page 6 of 22
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
4.3.2
CONTENTS
4.3.3
FORMAT
EJECT
By pressing the [EJECT] icon, the Recording Window is upgraded with by default values and the tape is
ejected from the unit.
4.4
This Area informs graphically about the portion of the tape that have been used (tape portion's
percentage with data stored). The displayed native tape capacity is not the tape's real capacity, it refers
the capacity with the fields compressed.
Tape Busy Area is represented by this part. The capacity of the tapes may be configured offline by GTI
tool.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 7 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
After formatting the tape, the tape capacity (in %) will not be erased. The DRF Reboot is needed in order
to reset the tape capacity (in %).
4.5
This area displays the messages related to the recording and playback status.
The access to a particular tape require a period of time, this is the reason why the displaying of these
messages on the DRF window cannot be immediate.
The vertical scroll bar allows visualizing all the hidden messages because of the limited size of the
window.
INFORMATION AREA
4.6.1
Introduction
Chapter 4
Page 8 of 22
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
The [CANCEL] icon is located at the bottom of both windows. By pressing with the LB of the mouse on
the icon, the window is closed. To visualize the window again, press with the LB on the [TAPE 1] or
[TAPE 2] icons.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 9 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
If the window position was changed manually, the DRF shows (the next times) the windows in the last
position.
Not always appears bellow to the corresponding tape, depending on the last position of the information
window.
Chapter 4
Page 10 of 22
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
4.6.2
Playback window
The Playback Window is displayed when pressing on the corresponding [TAPE1] or [TAPE2] icons (when
the tape status is in Reproduction mode) and allows to the operator to perform all the actions related with
data playback.
The next paragraphs describe the different areas of the Playback Window.
4.6.2.1
Commands Area
Description
It shows the tape content. Allowed in General Command Area
It transfers the existing files on the playback tape to a SDD in according with the selected files.
It filters the data displaying on the Playback Window.
It closes the Playback Window.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 11 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
The next paragraphs will explain the functionality of the above icons.
4.6.2.1.1
CONTENTS
When pressing the [CONTENTS] icon, the files kept on the playback tape are visualized at the
Information Area. This icon will remain in yellow colour (inhibited) until the whole set of files is not fully
displayed.
The TOTAL FILES, FROM and TO fields will be upgraded with current values contained on the playback
tape.
4.6.2.1.2
LOAD
1. Data Selection
2. Data Load
4.6.2.1.3
DATA SELECTION
The operator must select the start and the end playback time at the Time Period Selection Area.
Additionally, the operator must select, at the Date & Time, SDD selection Area, the SDD to be replicated
and the SDD where the playback will take place.
4.6.2.1.4
DATA LOAD
When pressing the [LOAD] icon, the Files Transfer Window is displayed. This icon will remain in yellow
colour (inhibited) until the files transfer process is finished (or aborted).
Files which comply with the conditions described in the Time Period Selection Area will be
displayed on the Contents Information Area after push Filter bottom. These files will be
transferred to a position previously selected.
The file transfer will not be carried out when data displayed on the Time Period Selection Area and/or on
the SDD Selection Area are erroneous. In this case, an error message will inform the controller about this
circumstance.
Chapter 4
Page 12 of 22
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
The Files Transfer Window displays messages informing to the controller about the way to perform a
proper data load.
Deleting directories.
Recomputing files.
Copying files
Finally, the END OF LOAD OPERATION message is displayed when the process is over.
The vertical scroll bar allows the displaying of hidden messages because of the limited window size.
Two icons are located at the bottom of the window:
Table 4: Files Transfer Window Buttons
Icon
CLOSE
ABORT
Description
It closes the Files Transfer Window.
It ends the transfer process drastically without performing the data loading process.
The [CLOSE] icon remains in yellow colour (inhibited) until the files transfer process is over.
4.6.2.1.5
FILTER
The [FILTER] icon allows the operator to filter the information to be displayed on the screen. So that, the
operator can display relevant information and eliminate the irrelevant one.
The [FILTER] icon remains in yellow colour (inhibited) until the files displaying on the Playback
window.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 13 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
If the fields on the Time Period Selection Area are erroneous, no file will be displayed on the Contents
Information Area and no System Warning Message will be displayed.
4.6.2.2
This area informs about the whole set of files kept on the playback tape. (Filtered or Total depending of
selections and actions).
The information proposed is:
LENGTH: Size.
DATE/TIME: Date and time corresponding to the file generation on the tape.
Chapter 4
Page 14 of 22
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
YYYYMMDDHHYYYYMMDDHH.sddx.Z
For instance, 20020619232002062000.sdd21.Z contains data starting at 23h on the 19/June/2002 until
00h on the 20/June/2002. The source of these data is the SDD21 position and data have been
compressed.
The vertical scroll bar allows visualizing hidden files because of the limited area size.
At the bottom of this Content Information Area, there is the total number of files within the tape (TOTAL
FILES) and the date and hour corresponding to the recorded data (FROM TO).
4.6.2.3
On the Time Period Selection Area, the operator can use the following parameters to filter:
Select Initial and Final Dates and Times for Files Transfer.
To select the elements, the operator can use the arrows by mouse to increase () or to decrease () the
set of values according with the requirements.
Table 5: Date and Time. Fields Description
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 15 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
TO (Final instant)
YYYY
MM
DD
HHMM
YYYY
MM
DD
HHMM
Year
Month
Day
Hour and
Minutes
Year
Month
Day
Hour and
Minutes
Description
TIME
Year
Month
Day
Hour
Minutes
Seconds
TIME
4.6.2.4
Year
Month
Day
Hour
Minutes
Seconds
In this area the operator must select the SDD to be replicated and the SDD where the playback will take
place.
This action is performed by means of scroll bars located beside the following fields:
Table 7: SDD Selection Area
Field
What Pos
Where
Description
This field selects the SDD to be replicated
This field selects the SDD where the playback will take place
To select the elements, the operator can use the arrows to increase () or to decrease () the set of
values according with the requirements.
Chapter 4
Page 16 of 22
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
4.6.3
Recording window
The Recording Window allows carrying out all the actions related with the Data Recording Process. This
window is accessible by pressing the [TAPE1] or the [TAPE2] icons when the status is Recording mode.
The next paragraphs describe the whole set of Areas belonging to this window.
4.6.3.1
LENGTH: Size.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 17 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
The format file contains specific information concerning its data. The formats are:
YYYYMMDDHHYYYYMMDDHH.sddx.Z
For instance, 20020620222002062023.sdd21.Z contains data starting at 22h on the 20/June/2002 until
23h on the 20/June/2002. The source of these data is the SDD21 position and data have been
compressed.
The vertical scroll bar allows visualizing hidden files because of the limited area size.
At the bottom of this Content Information Area, there is the total number of files within the tape (TOTAL
FILES) and the date and hour corresponding to the recorded data (FROM TO) (See Table 5: Date and
Time. Fields Description).
4.6.3.2
It displays the files that have not been recorded yet. These files are immediately removed from this area
when the recording process has been accomplished successfully.
PENDING FILE LIST is displayed in white colour when the list is empty and in red colour when the list is
not empty.
The total number of these files (TOTAL FILES) and the Date and Hour corresponding to the recorded
data (FROM -TO) are indicated at the bottom of this area (See Table 5: Date and Time. Fields
Description).
Chapter 4
Page 18 of 22
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 19 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
4.6.4
ACTION
If the Playback Window is not displayed on the screen, press on the
icon concerning the tape used ([TAPE2] or [TAPE1] in reproduction
mode icon in white colour).
Select Date and Time corresponding to the initial and final instants.
Increase or decrease the number by means of scroll bars.
Chapter 4
Page 20 of 22
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
RESULT
ACTION
Select the SDD Position.
Increase or decrease the number by means of scroll bars.
It displays, on the Playback Window, the files that fulfil the selected
filter.
ABORT
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 4
Page 21 of 22
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Chapter 4
Page 22 of 22
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
5.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 5
Page 1 of 10
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Control Area.
5.3.1
The sources of the information displayed on this area are files locally recorded at the SDD (24 hours
playback) or the selected Date/Hour for playback at the DRF position.
It allows to the operator the selection of a part of the available information for playback when selecting the
start and final date and time (as described for the DRF position).
Table 8: SDD Playback Control Window. Time Period Visualization Area
Fields
Description
TIME
Year
Month
Day
Hour
Minutes
Seconds
Chapter 5
Page 2 of 10
Year
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
TIME
Month
Day
Hour
Minutes
Seconds
To select the elements, the operator can use the arrows to increase () or to decrease () the set of
values according with the requirements.
5.3.2
Control Area
Description
Start.
Temporary pause.
Stop.
Back rewind.
SPEED
x1
After pressing the button for display of windows and lists it is not possible to stop the playback. In order
to enable the stop button it is necessary to press F1 key.
F2 key allows to hide the SDD Playback Control Window in passive mode. This Window can be displayed
again by F1 key and then displaying it again.
NOTE: Passive playback does not allow interaction with information and windows displayed.
5.3.3
This area displays System Messages that inform about playback warnings in real time; it is when the
process is taking place. The [OK] icon removes these messages.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 5
Page 3 of 10
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Chapter 5
Page 4 of 10
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Description
Name corresponding to the replicated SDD.
Date of reproduction.
Hour corresponding to the process.
Bypass operative status mode.
Range value.
Altitude filters used.
Not available.
Maps selected.
Quick look sectors.
Quick look status.
Current filters status.
Main menu status.
Automatic bearing status.
Status concerning the historic of the tracks.
Speed vector display.
Primary plot display.
Primary tracks display.
Secondary plots display.
Uncorrelated secondary tracks display.
Correlated secondary tracks display.
Display of plots containing meteorological information.
Symbol size concerning tracks and characters.
Speed vector size.
Track label format.
Track historic number.
PVs list status.
Special areas display.
RBL alarm.
Chapter 5
Page 5 of 10
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Three options are eligible for picture saving in the CAPTURING PICTURE window depending on the
switch activated. The next table shows the meaning of every switch:
Table 5-11:
SWITCH
TO FILE
TO PRINTER
(As Shown)
TO PRINTER
(No Black)
The SDD picture is saved in the /local/<proj>/sdd/execscreen_files/ directory with PostScript (.ps extension) format.
The SDD picture is printed as it is displayed.
The SDD is printed replacing black colour with white colour for unuseful ink waste avoidance.
Chapter 5
Page 6 of 10
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
RESULT
Press the [PLAYB CTR] bi-state icon on the Main Menu Window.
Back rewind.
Forward rewind.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 5
Page 7 of 10
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
ACTION
The Playback process ends by pressing again the [PLAYB CTR] bistate process on the Main Menu Window.
RESULT
The Playback Control Window is closed.
RESULT
5.7.1
Application: This action allows to change playback mode, from passive to interactive and vice versa,
allowing to interact with the playback display or just display in video mode.
ACTION
Start the playback process in CMD (24-hour playback or historical
playback).
RESULT
The SDD starts up in selected playback mode.
Press the [PLAYB CTR] bi-state icon on the Main Menu Window.
The playback is started in passive mode, which does not allow any
interaction with the displayed playback.
Chapter 5
Page 8 of 10
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
ACTION
Press F1 key.
RESULT
The playback turns into interactive mode, allowing to perform some
actions.
RESULT
The Playback Status Window is displayed.
The status of the SDD functions is shown on the window during the
interval of time devoted to the playback process selected previously.
Finish the action by pressing the [PLAYB DAT] bi-state icon.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 5
Page 9 of 10
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Chapter 5
Page 10 of 10
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
6.
When the system has problems the technical staff needs following the next steps.
6.1
TAPE STATUS
The best test to know tape status is seeing it in CMD position. In the next table is possible see the tape
status.
Table 12: Tape Status in Supervisor position
Icon
Description
Tape:
White: in reproduction mode
Yellow: Recording status
Dark RED: not operative
Dark GREEN: incorrect status
Tape not formatted
Tape with data
Tape formatting
Tape OK
Tape recording
Tape protected
Tape full (in YELLOW and, after 3 minutes, in RED)
Tape playing
Tape error
Tape out
When the colour of the tape is WHITE: the tape is in playback mode.
When the colour is YELLOW: the tape is in recording mode.
6.2
When the SDD send one file at DRFs, the SDD take two ways, LAN1 or LAN2. If the SDD cannot copy
this backup files, the system need that the technical execute the next actions.
Remark: This procedure is for different cases:
DRF1 and DRF2 are shutdown when the files are transferred by the SDDs.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 6
Page 1 of 6
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
6.2.1
It is necessary to use cleaning tapes for each Unit Tape following a periodic procedure. In other case, the
tapes can corrupt stored data.
In the case when the message "TAPE NOT WORKING" appears in DRF and CMD, after each writting
attempt, it is recommended to do the following steps:
6.2.2
3 : In remote mode, and for all SDDs, the technical operator need execute the next command:
Go to DIRECTORY for each SDD: /local/<proj>/sdd/exec/grabacion
Need EXECUTE this command: gunzip *.Z. (Only in the files that not copied at DRF)
Chapter 6
Page 2 of 6
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
th
4 : Start-up DRFs. In this moment, automatically, the DRFs verify all SDD to copy all files at the
pendientes directory of the DRFs.
th
6.3
Manual format:
6.3.1
2 Tapes formatted
DRFs Messages:
No data on disc.
DRFs ACTIONS:
Check tapes.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 6
Page 3 of 6
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
Chapter 6
Page 4 of 6
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
6.3.2
The tape 1 contains information but the tape 2 doesnt contain information.
DRFs Messages:
DRFs ACTIONS:
Check tapes.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 6
Page 5 of 6
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
6.3.3
DRFs ACTIONS:
Check tapes.
Chapter 6
Page 6 of 6
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
7.
SYSTEM MESSAGES
This point lists the advice messages displayed by the system as an answer to the operator actions.
7.1.1
System messages
NO DATA ON TAPE.
This tape not contains data.
TAPE i OPERATIVE.
This is the first message. It indicates that the tape x is used for data recording.
The following paragraphs show the full set of available messages.
FORMATTING TAPE.
When the tape is formatting in this moment.
BEGIN OF RECORDING.
The tape is not formatted. The format process is automatically started to perform the recording.
BEGIN OF REPRODUCTION.
TAPE IS WRITE-PROTECTED
The tape is write-protected and the recording process cannot start.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 7
Page 1 of 3
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
The tape contains files. This warning message is displayed before starting the format process
when an automatic or manual change of tape is detected and when the [FORMAT] icon is
pressed.
7.1.2
Error messages
When the data or time within the END field are earlier than those of the BEGIN field.
When the delay of time between the time corresponding to the BEGIN and the END fields is
bigger than ten (10).
NO DATA ON TAPE.
This message is displayed in two cases:
The files on the tape do not match the conditions selected on the Time Period Selection Area.
The position selected at the WHERE? field does not exist or is not operative.
DATA DISCONTINUITY.
Chapter 7
Page 2 of 3
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
(DRF-UM)
Actualizacin, Instalacin y Puesta en Funcionamiento del Sistema de Vigilancia Aeronutica
para el Centro de Control de Bogot / AirCon 2100
7.1.3
7.1.3.1
Eject
7.1.3.2
Format
FORMATTING TAPE.
BEGIN OF RECORDING.
Doc.N:
Edit./Rev.: A/0
Date: 09/07/2012
Chapter 7
Page 3 of 3