Bharti FM-BSS

1 (55)
24-Apr-2014

BHARTI GDC FM-BSS


Troubleshooting Doc for Day to Day Activities

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

2 (55)
24-Apr-2014

TABLE OF CONTENTS
1

WDU Replacement ..........................................................................3

NSEI Deletion Creation..10


1. NSEI deletion creation Frame based11
2. NSEI shifting to another BCSU Frame based12
3. NSEI deletion creation GB ov IP based..13
4. PCU Pooling Implementation

Discriminator Clearance16
1. Discriminator clearance.17
2. BSDATA & PDDATA clearance18
3. OMU & MCMU process restart.18
4. CMISE application restart..19

Procedure to Take BSC Backup on Laptop.20

Revert BSC on Fall Back (Delete the DBI* and DBA* files)26

Incraese BSC Alarm Buffer Size..28

BSC Fallback copying Error..31


2663-DUMPING ERROR IN DATABASE MANAGER..32
2393-FALLBACK COPYING TERMINATED IN ERROR..32

EMB Troubleshooting.36

MB Troubleshooting40

10 BSC Fallback & MO Disk (FDU) Backup.47


11 BSC Login via OMU (CPU J7 Port)...51
12 PCU Pooling Concept/Troubleshooting.53
13

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

3 (55)
24-Apr-2014

WDU REPLACEMENT PROCEDURE

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

4 (55)
24-Apr-2014

REPLACING A HARD DISK UNIT (WDU)


MUST REMEMBER
You should have an initialized WDU at your disposal. Here we assume WDU-1 is faulty and during the activity
please mind the below points.
1) Block Command Calendars
2) Make sure there should be no other activity is in process during the replication process i..e.step-22
3) Stop all activities on the SCSI bus(like FDU) where you are making changes

PROCEDURE
1. Find the states of the WDUs (EG:-WDU-1)
ZISI: :WDU,1:;
2. Dump the data files from OMU and MCMU to disks of OMU
ZDFC:OMU;
ZDFC:MCMU,0; (Working MCMU)
NORMALLY THESE COMMAND END WITH ERROR"
/*** DX ERROR: 11502 ***/
/*** UPDATE FAILED TO I/O UNIT W1 ***/
3. Copy ALL databases from memory to disk
ZDBC:BSDATA,0;
ZDBC:EQUIPM,0;
ZDBC:OEDATA,0;
ZDBC:ILDATA,0:;
ZDBC:PDDATA,0:;
4. See the database file in BSC
ZDBL:;
ZDUR;
"EXP.
BSC3i

B012GAY1

2010-10-24 02:46:26

DATABASE OCCURRENCE UNIT


BSDATA
EQUIPM
OEDATA

0
0
0

MCMU
OMU
MCMU

019B
01C5
0262

DB FAMILY FILES BASE DB IDENTIFIER


06390000
06A50000
07BD0000

For internal use only Nokia Solutions and Networks

0009
0011
0022

For internal use only

Bharti FM-BSS

ILDATA
PDDATA

5 (55)
24-Apr-2014

0
0

OMU
MCMU

0679
06AE

0B640000
0BA60000

0069
006A

5. Prevent file updates and disk updates of databases


ZDUP:;
6. Prevent file updates and disk updates of databases
ZDBP:<database name>,<occurrence>:DISK;
ZDBP:BSDATA,0:DISK;
ZDBP:EQUIPM,0:DISK:;
ZDBP:OEDATA,0:DISK:;
ZDBP:ILDATA,0:DISK:;
ZDBP:PDDATA,0:DISK:;
7. Check for database either they get Prevent or not
ZDBS:BSDATA,0;
ZDBS:EQUIPM,0;
ZDBS:OEDATA,0;
ZDBS:ILDATA,0;
ZDBS:PDDATA,0;
NOTE: O/P should be
MEMORY UPDATES PREVENTED SHOULD BE " YES " STATE
DISK UPDATES
PREVENTED SHOULD BE " YES " STATE
8. Check that all databases have been unpacked from the disk log to the disk database (DBX)
The command unpacks the disk logs if they are not empty.
ZDBX:<database name>,<occurrence>;
ZDBX:BSDATA,0:;
ZDBX:PDDATA,0:;
ZDBX:ILDATA,0:;
ZDBX:EQUIPM,0:;
ZDBX:OEDATA,0:;
9. CHECK THE PLUG-IN INFO OR FIND THE TRACK NO OF PLUGIN UNIT

ZWTI:P:OMU:;

10. Block the WDU you are changing to BL-US state


ZISC:,<destination unit>,<pair>:<I/O device type>,<I/O device index>:<working state>;
ZISC::WDU,1:BL-US,;
ZISC::WDU,1:MI-US,;
11. Block the other I/O devices (FDU) on the same unit pair's SCSI bus

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

6 (55)
24-Apr-2014

ZISC::FDU,00:BL-US,;
12. Check that the state of the hard disk to be replaced is correct (BL-US/MI-US)
ZISI:,<destination unit>,<pair>:<I/O device type>,<I/O device index>;
13. Remove the WDU from the OMU computer cartridge:
1) Switch off power by pressing the 'OFF' button and wait about 7 seconds, until the 'Power Off' led lights.
2) Remove the WDU unit from the cartridge.
14. Check the jumper settings of the new WDU.
15. Install the new WDU to the OMU computer cartridge:
Install the WDU to the cartridge and wait about 3 seconds, Until the 'OFF' led is off.
16. After placing new WDU, Change the state of the new WDU to WO-ID (ISC)
ZISC:,<destination unit>,<pair>:<I/O device type>,<I/O device index>:<working state>;
ZISC::WDU,1:WO-ID,;
17. Check that the new disk is the backup disk (WB) (IWQ)
***Note that the command does not end in a semicolon.
ZIWQ:,<destination unit>,<pair>
BY COMPAIRE THIS WITH ZISI::WDU;
IF WDU-0 is Faulty then WS=1,
IF WDU-1 is Faulty then WS=0,

WB=0
WB=1

18. Format the new hard disk. (This process can take 30 to 60 min.)
Initialize WDU
ZIWI:,OMU:WB,F5,NAME,FFF,02,AG:;
Format WDU
ZIWK:,:WB,,NAME,FF,,AG:;
19. Change the states of other I/O devices on the same SCSI bus (Change the states of FDU to WO-BU)
20. Diagnose the WDU (UDD)
Before diagnostic, change the state of WDU to TE-ID using command ZISC::WDU,1:TE-ID;
ZUDD: <main unit type>, <pair>, <main unit index>: <device type>, <device index>;
ZUDD:OMU,0:WDU,1;
For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

7 (55)
24-Apr-2014

If the diagnosis is successful, you will see diagnostic report 3999 DIAGNOSIS EXECUTED - UNIT OK
21. Change the working state of the new WDU to WO-BU (ISC)
ZISC:,<destination unit>,<pair>:<I/O device type>,<I/O device index>:<working state>;
ZISC:,OMU:WDU,1:WO-BU;
22. Copy the system WDU to the new WDU (IPS) including subdirectories, using the default and active build
directory name 'ASE_1_28_0'. Use ZWQO:CR; to verify build directory name.
ZIWY:S:SYSTEM=,UNIT=OMU,PATH=/,DRIVE=WDU-S,; (Create Source)
ZIWY:D:SYSTEM=,UNIT=OMU,PATH=/,DRIVE=WDU-B,; (Create Destination)
ZIBC:,,,,,,,,,DIR:;

(Copy Source to Destination)

****IF Files are not getting transfer to new disk using above commands, then need to create source
and destination using below commands****
ZIPS:<source unit>,<source I/O device>,<source path>,,:,<destination I/O device>,<destination
path>,,:<directory mode>,<copy task name>;
ZIPS:"OMU",WDU-S,/ASB_1_34_0,:,WDU-B,/,:DIR=INC,NAME=COPY,;
ZIPS:OMU,WDU-S,/ASC_1_40_0,:,WDU-B,/,:DIR=INC,NAME=COPY;

OR

ZIPS:,WDU-S,/,,:,WDU-B,/,:NAME=COPY,DIR=INC,::;
Now, Check the progress of the copy task to see when it is ready.
ZIPI: NAME=<copy task name>;
23. Kill GEORGE Use service terminal command to prevent the log files of Q3 Disseminator getting corrupted.
ZDDS:;
00-MAN>OD: 2B1
24. Remove LOGRECS* files from the disks LFILES on both OMU disks
Use service terminal command MD in order to maintain the required syncronisation status between
DEEGUT and GEORGE during the hard disk change. Use ZWQO:CR; to verify build directory name. Here
build directory name is ASE_1_28_0.
ZMD: W0-/<Build directory name>/LFILES/LOGR*.*
ZMD: W1-/<Build directory name>/LFILES/LOGR*.*
ZDDS:;
For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

8 (55)
24-Apr-2014

WELCOME TO SERVICE TERMINAL DIALOGUE


00- MAN>ZMD:W1-/ASE_1_28_0/LFILES/LOGR*.*

(Also use the same command for W0)

Sample Output:
DELETING FILE: W1-/ASE_1_28_0/LFILES/LOGRECSD01.DAT:00
EXECUTED
DELETING FILE: W1-/ASE_1_28_0/LFILES/LOGRECSD03.DAT:00
EXECUTED
DELETING FILE: W1-/ASE_1_28_0/LFILES/LOGRECSD02.DAT:00
EXECUTED
DELETING FILE: W1-/ASE_1_28_0/LFILES/LOGRECSD04.DAT:00
EXECUTED
00000004 FILES DELETED
25. Resume updates of disks and memory file disk copies of the databases which you prevented before
changing the WDU
ZDUR;
ZDBR:BSDATA,0:DISK;
ZDBR:EQUIPM,0:DISK:;
ZDBR:OEDATA,0:DISK:;
ZDBR:ILDATA,0:DISK:;
ZDBR:PDDATA,0:DISK:;
26. Check that the database states are restored to 'normal' or 'dumping' (DBS)
ZDBS:<database name>,<occurrence>; //The command displays the states of the databases.
ZDBS:BSDATA,0;
ZDBS:EQUIPM,0;
ZDBS:OEDATA,0;
ZDBS:ILDATA,0;
ZDBS:PDDATA,0;
NOTE: O/P should be
MEMORY UPDATES PREVENTED SHOULD BE " NO " STATE
DISK UPDATES
PREVENTED SHOULD BE " NO " STATE
27. Copy the data from database to disk
ZDBC:<database name>,<occurrence>;
ZDBC:BSDATA,0:;
ZDBC:EQUIPM,0:;
ZDBC:OEDATA,0:;
ZDBC:ILDATA,0:;
ZDBC:PDDATA,0:;

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

9 (55)
24-Apr-2014

28. Check that the states of the units are correct (WO-EX, SP-EX) (USI)
ZUSI:<unit type>,<unit index>;

29. Restart OMU (USU)

ZUSU:OMU:C=DSK;

30. Take Fall Back


ZWKS:MODE=FULL,NAME=FB011211,DIRE-FB011211:;
31. Check for consistency of both BU & FB packages
ZWQB:NAME=directory_name:FORM=FAILED:;

SOME POINTS NEED TO BE CHECKED AFTER THE ACTIVITY


1) Check state of both WDU
2) Check Measurements are getting transfer or not atleast for next two hours. If found any issue escalate
the same to your SPOC and perform necessary action.
3)

Check for critical alarms at BSC.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

10 (55)
24-Apr-2014

NSEI DELETION & CREATION STEPS

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

11 (55)
24-Apr-2014

NSEI DELETION AND CREATION STEPS (FRAME BASED)


PROCESS-1
1) Find the Name of NSEI by executing below command and take all required pre activity log.
ZFXO:BCSU=0&&6:;
ZFXO:BCSU=0&&6:BTS;
2) First note down the given below parameter very carefully.
NS-VC ID
Name
DLCI
CIR
Bearer ID
Channel Name (BCN)

06655 (for eg)


NS_TEL65_5
655
448
0005
BSC65TEL_5

3) Either shift the DAPs to another NSEI or make GENA disable for all BTS which are attached to particular
NSEI on which we are working.
ZEQV:SEG=<seg_no>:GENA=N:;
4) Lock the NSEI using below command
ZFXS:NAME=<nsei_name>:L;
5) Delete NSEI using the below command
ZFXD:NAME=<nsei_name>;
6) Create NSEI

(NSEI SAME AS NSVCI)

ZFXC:NSVCI=06655;NAME=NS_TEL65_5,NSEI=06655:DLCI=655,CIR=448:BCN=BSC65TEL_5:;
7) Unlock NSEI and check NSEI state
ZEFS:NAME=nsei_name:U;
8) Attach cells to NSEI after coming to WO state by making GENA enable for all BTS.
ZEQV:BTS=bts_no:GENA=Y:;

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

12 (55)
24-Apr-2014

STEPS TO SHIFT NSEI TO ANOTHER BCSU


PROCESS-2
1) First of all perform STEP-1 to STEP-5 as given in process-1 and then only delete the Frame Relay
(Bearear ID) using below command. Here Bearear ID is 5.
ZFUD:5,NS_TEL65_5:;
2) Create Frame Relay (Bearear ID) to another BCSU
ZFUC:5,NS_TEL65_5:5:106,17:BCSU,1,3:;
Here
5 is Bearear ID,
NS_TEL65_5 is NSVCI Name,
5=320/64
DIR/64
17 is starting PCM
Sample Output
BEARER BEARER
BEARER
CHANNEL EXTTIME
ID
NAME
RATE (KBIT/S)
PCM
SLOTS
UNIT
TERM FUNCT
------ ---------- -------------- ---- ------ ------ ---- ------------------------------------------------------------315 B180KOC1_2
384
530
13-18
BCSU-3
3
0

3) Now execute STEP-6, 7 & 8 as given in the above process-1.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

13 (55)
24-Apr-2014

NSEI DELETION AND CREATION STEPS (GB OV IP BASED)


PROCESS-3
1) Find out the number (i.e. ID) of NSEI & PSEI by executing below command and take all required pre
activity log.
ZFXI:NSVLI=0&&65535:;
ZFXL:PSEI=0&&99:BTS:;
ZQRI;
ZQKB;
2) First note down the given below parameter very carefully.
i. IP address of PCU IFETH port using command ZQRI
Say IP for BCSU-1 & PCU2D-3 IFETH0/ IFETH1 is 172.26.128.39
IP for BCSU-1 & PCU2D-4 IFETH0/IFETH1 is 172.26.128.40
ii. Default Gateway IP address using command ZQKB. Here Gateway IP is 172.26.128.34
iii. Note down the NSEI & PSEI number. Here, NSEI are 1783 & 1784 and PSEI are 2 & 3. If NSVCI not
found error encounter, then get the down NSVLI NO from PSEI data.
iv. Note Down NSEI Name, RSW, RDW, LPNBR, RPNBR & RIP(REMOTE IP ADDRESS) using ZFXL
command.
NAME= NS_JRK78_3 and NS_JRK78_4
RIP= 10.246.224.43
RSW=1,
RDW=1,
LPNBR=50023 and 50024,
RPNBR= 50023 and 50024,
v. Note down the segment using below command
ZEBP:NSEI=<NSEI_No>;
3) Disable GENA in all cells attached to particular NSEI.
ZEQV:SEG=<seg_no>:GENA=N:;
4) Delete the problematic NETWORK SERVICES VIRTUAL LINK (NSVLI).
ZFXH:NSVLI=1783:;
ZFXH:NSVLI=1784:;
5) Delete PACKET SERVICE ENTITY (PSEI, Corresponding to NSVLI)
ZFXE:PSEI=2:;
ZFXE:PSEI=3:;
For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

14 (55)
24-Apr-2014

6) Delete Static Route (For static route check ZQKB; output)


ZQKA:(STATIC Route no):;
7) Delete IP addresse from interfaces (IFETH0 & IFETH1)
ZQRG:BCSU,1:PCU2D,3:IFETH0:"172.26.128.39":;
ZQRG:BCSU,1:PCU2D,3:IFETH1:"172.26.128.39":;
COMMAND format If PCU_B PIU is in use
ZQRG:BCSU,<BCSU NO>:PCUB,<PCU NO>:IFETH0:"<IP ADDRESS>":;
ZQRG:BCSU,<BCSU NO>:PCUB,<PCU NO>:IFETH1:"<IP ADDRESS>":;
COMMAND format If PCU2_D PIU is in use
ZQRG:BCSU,<BCSU NO>:PCU2D,<PCU NO>:IFETH0:"<IP ADDRESS>":;
ZQRG:BCSU,<BCSU NO>:PCU2D,<PCU NO>:IFETH1:"<IP ADDRESS>":;
8) Now check for ETH interfaces using command ZQRI;
9) Configure network interfaces
ZQRA:BCSU,1:PCU2D,3:IFETH0:::;
ZQRA:BCSU,1:PCU2D,3:IFETH1:::;
10) Configure IP addresses to IFETH
ZQRN:BCSU,1:PCU2D,3:IFETH0,:"172.26.128.39",27,L::;
ZQRN:BCSU,1:PCU2D,3:IFETH1,:"172.26.128.39",27,L::;
OR (Use below command instead of above two)
ZQRN:BCSU,1:PCU2D,3:IFETH0,IFETH1:"172.26.128.39",27,L::;
COMMAND Format if PCU_B is used
ZQRN:BCSU,<BCSU NO>:PCUB,<PCU NO>:IFETH0,IFETH1:"<IP ADRRESS>",NET MASK LENGTH( Eg- 27),L,::;
COMMAND Format if PCU2_D is used
ZQRN:BCSU,<BCSU NO>:PCU2D,<PCU NO>:IFETH0,IFETH1:"<IP ADRRESS>",NET MASK LENGTH( Eg27),L,::;
11) Create Static Route
ZQKC:BCSU,1:PCU2D,3::"172.26.128.34":LOG:;
ZQKC:BCSU,1:PCU2D,4::"172.26.128.34":LOG:;
COMMAND Format
ZQKC:BCSU,BCSU NO:PCU_B/PCU2_D,PCU NO::"GATE WAY IP ADDRESS":LOG:;
For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

15 (55)
24-Apr-2014

12) Test host reachability (PING/TRACEROUTE)


ZQRX:BCSU,1:PCU2D,3::IP="172.26.128.34",:;
ZQRX:BCSU,1:PCU2D,4::IP="172.26.128.34",:;
13) If host reachabily is ok then create PSE
ZFXA:PSEI=2,BCSU=1,PCU=3;
ZFXA:PSEI=3,BCSU=1,PCU=4;
COMMAND Format
ZFXA:PSEI=02,BCSU=BCSU NO ,PCU=PCU NO,:;
14) Create NSVLI

(NSEI number same as NSVLI number)

ZFXK:NSVLI=1783,NAME=NS_JRK78_3,NSEI=1783,PSEI=2:LPNBR=50023,PRE=N:RPNBR=50023,RSW=1,RD
W=1, RIP="10.246.224.43";
ZFXK:NSVLI=1784,NAME=NS_JRK78_4,NSEI=1784,PSEI=3:LPNBR=50024,PRE=N:RPNBR=50024,RSW=1,RD
W=1, RIP="10.246.224.43";
COMMAND Format
ZFXK:NSVLI=<NSVLI NO>,NAME=<NSVLI NAME>,NSEI=<NSEI NO>,PSEI=<PSE NO>:LPNBR=<LOCAL UDP
PORT NO>,PRE=N:RPNBR=<REMOTE UDP PORT NO>, RSW=001, RDW=001,RIP="REMOTE IP ADDRESS":;
RSW, RDW, LPNBR, RPNBR & REMOTE IP ADDRESS will get from STEP-2 or Prelog.
15) Check for NSEI state and enable GENA in all BTS/Segments.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

16 (55)
24-Apr-2014

DISCRIMINATOR CLEARANCE PROCEDURE

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

17 (55)
24-Apr-2014

DISCRIMINATOR CLEARANCE
Discriminator clearance activity can be performed during below given scenario1) RNW Network Plan Database state is INTERRUPTED BY SYSTEM. Use ZEEK command to check the same.
(Execute Step-A, B, C)
2) Sometimes when MO Upload getting failed.
3) Not able to lock/Unlock sector or site. (Execute Step- B, C, D & G only one by one)
4) Getting Fetching Error while CM performing BTS software download from software manager
5) Getting error NO RESOURCE FOR REQUESTED TASK while changing name using CM edtor.

MUST REMEMBER BEFORE ACTIVITY


1) Plan the activity during maintenance window with proper outage approval.
2) Remember to make a valid FALLBACK
3) Stop command Calendar and resume after completion of activity

PROCEDURE
A) If problem is related to Upload than first of all check ZEAT output, and delete all the cells captured. If
output is blank than perform the next procedure.
B) Discriminator clearance Steps
ZDDS:;
ZL:2
ZLE:2,EXODUSGX
2
D:1,DEAD
After performing the above, ensure that all are 0000 except for Windows currently in use, by using
the following commands and exit:
S:1
S:2
S:3
S:4
SAMPLE OUTPUT
*************************************
Windows currently in use
=
Last window written to disk
=
Number of records in the que
=
Amount of bytes used
=
Identifier of the first record
=

For internal use only Nokia Solutions and Networks

0001
0000
0000
0000
0000

For internal use only

Bharti FM-BSS

18 (55)
24-Apr-2014

Identifier of the last record


=
Last ULA record written
=
*************************************

0000
0000

Now, delete the Dissiminator Extension, using the command L:2 and exit the service terminal using
ZE.
C)

Change plan database state to clear in active database (BSDATA)


ZDDS:;
ZLE:Q,DAEMONGX
ZQD:6390000,4505,19B
ZQM:412,T:00,XD5CEF,XD5CEF,XD5CEF
Wait for 5 min and then go to the next step

D)

Change at last plan database state in plan database (PDDATA)


ZQD:BA6002A,4505,6AE
ZQM:231,T:00,XD5CEF,XD5CEF,XD5CEF
Now, Perform OMU restart from Disk( C= DSK)
Please check ZEEK (it should be clear) and if still problem exists please restart below given process on
OMU as well as both active MCMU's and check.

E)

Clear both the DOWNLOAD & UPLOAD directories


ZIWD::WSB, DEF:DOWNLOAD:%,%;
ZIWD::WSB, DEF:UPLOAD:%,%;

F)

Clear the SEND2NW directory


ZIWD::WSB, NODEF:SEND2NW:%,%;

G)

Restart CMISE applications


ZQDI;
Lock CMISE applications
ZQDG:BSC938784A,LOC;
ZQDG:BSC938784EHA,LOC;
ZQDG:OMC000000D1,LOC;
ZQDG:OMC000000BP,LOC;

(change C number of BSC, marked in red color)

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

24-Apr-2014

Unlock CMISE applications


ZQDG:BSC938784A,UNL;
ZQDG:BSC938784EHA,UNL;
ZQDG:OMC000000D1,UNL;
ZQDG:OMC000000BP,UNL;
H) Perform OMU code loading restart

ZUSU:OMU:C=DSK;

<ZEEK;
output should be

BSC3i

BSC23JAY

19 (55)

2011-01-21 10:21:45

RADIO NETWORK PLAN DATABASE STATES IN BSC:


RNW PLAN DATABASE STATE ............................ CLEAR
RNW CONFIGURATION ID ............................... 2334
RNW PLAN CONFIGURATION ID .......................... 2334
RNW FALLBACK CONFIGURATION ID ...................... 2100

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

20 (55)
24-Apr-2014

PROCEDURE TO TAKE BSC BACKUP ON LAPTOP

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

21 (55)
24-Apr-2014

TAKING BSC BACKUP ON LAPTOP


1) First install FTT software in laptop. If already installed go to the next step.
2) Take the valid Fallback with below MML command.
ZWKS:MODE=FULL,NAME=FBddmmyy,DIRE=FB_ddmmyy;
3) Use- ZQRI:; command to check BSC IP.
4) In BSC3i, use Ethernet port available in ESB card in LANU or MCMU (ETH1 or ETH2) to connect laptop
trough FTT.
In BSC2i, use Ethernet port available in OMU section.
5) Open FTT application to take BACK UP on Laptop.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

6) Go to Setup in menu bar of FTT application

Continue.

For internal use only Nokia Solutions and Networks

22 (55)
24-Apr-2014

For internal use only

Bharti FM-BSS

7)

23 (55)
24-Apr-2014

Make the new connection for BSC login (Provide IP, User Name & Password) & save.

Continue.
For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

24 (55)
24-Apr-2014

8) Open the New connection, click on Open FTP tab.


In the left side, BSC data shown & in the right side Laptop C drive data shown.

9) Open the Fallback directory in the BSC side (left side)


10) Make a folder (with name fallback) in C drive, and then make all subfolders with the same name as in
Fallback directory in left side.

Continue.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

25 (55)
24-Apr-2014

11) Then Copy files from each folder with the same folders. (e.g.: files in left side under the folder BLCODE
should be copied in the right side (C drive) with the folder name BLCODE.
BSC SIDE

LAPTOP SIDE

BLCODE (all files) ---------------------------------------

BLCODE (all files)

-----------------------------------------------Process Completed------------------------------------------------------------

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

26 (55)
24-Apr-2014

RVERT BSC ON FALL-BACK

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

27 (55)
24-Apr-2014

STEP TO REVERT BSC ON FALL BACK


1.1 Restoring the software builds if the BU build is faulty and MML working
The fallback activation restores the situation that was present at the time the fallback was made. If
any changes have been made after the last fallback, the changes must be made again.
If the BU build is found to be faulty, the FB build can be restored to serve as the BU build.
1) Delete the DBI* and DBA* files from FB Package
ZIWD::WSB,NODEF:<FB_Package>,LFILES:DBI%,IMG;
ZIWD::WSB,NODEF:< FB_Package >,LFILES:DBA%,IMG;
2) Verify the consistency of FB package.
ZWQB:NAME=Fallback_name:FORM=FAILED:;
3) hange the FB build to be the default (WSD)
ZWSD:STAT=FB;
Where STAT= Status of the build which need to be restored.
Or
ZWSD:NAME=FB_040506;
Where NAME= Name of the build which need to be restored.
Note Changing the default build causes the system to restart. The system informs the user about
this and asks for verification.
4) When the FB build is working, roll back the status so that the FB build is changed to the BU build.
ZWSR;
5) Verify the consistency of the Build package again and perform BSC health check.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

28 (55)
24-Apr-2014

INCREASE ALARM BUFFER SIZE

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

24-Apr-2014

INCREASE ALARM BUFFER SIZE


Use below given steps to increase alarm buffer size of BSC
1. Interrogate the ALHIST on both Disks
a)
b)

29 (55)

ZIWX::WS:LFILES: ALHIST%, %:;


ZIWX::WS:LFILES: ALHIST%, %:;

<: OUTPUT :>


VOLUME NOKIA.DIR: 0 INITIALIZED 08-04-11
REL 5
DIRECTORY OF LFILES
LIMIT 2
==========================================================
FILE NAME
FILE
FILE FILE
DATA
PAGE 1
VERSION NO LENGTH LENGTH
CREATOR ATTR
(H) (H) (DEC) (DEC)
ALHISTGX

.ALF

TOTALS

AC

614400

614392 02 D

614912 614904 ( INCLUDING FIDS )

FREE LABELS IN DIRECTORY 1089


FREE BLOCKS IN DISK 115943842 ( 80 %) 56613 MB
DISK SIZE 143638992 BLOCKS 70136 MB

2. Delete the files from both Disk


ZIWD:,OMU:WSB,:LFILES:ALHIST%,%,;
3. Create a new file of 2MB
ZIWC::WSB:LFILES:ALHISTGX,ALF,2048000,AB:;
4. Check version of created file
a) ZIWX::WS:LFILES:ALHIST%,%:;
b) ZIWX::WB:LFILES:ALHIST%,%:;
<: OUTPUT :>
VOLUME NOKIA.DIR: 0 INITIALIZED 08-04-11
REL 5
DIRECTORY OF LFILES
LIMIT 2
===============================================================
FILE NAME
FILE FILE FILE
DATA
PAGE 1
VERSION NO LENGTH LENGTH CREATOR ATTR
(H)
(H) (DEC)
(DEC)
ALHISTGX

.ALF

AC

2048000

For internal use only Nokia Solutions and Networks

0 AB D

For internal use only

Bharti FM-BSS

TOTALS

30 (55)
24-Apr-2014

2048512

512 ( INCLUDING FIDS )

FREE LABELS IN DIRECTORY 1089


FREE BLOCKS IN DISK 115941042 ( 80 %) 56611 MB
DISK SIZE 143638992 BLOCKS 70136 MB
COMMAND EXECUTED

5. Set default version to new created ALHISTGX file


ZIWF::WSB:LFILES:ALHISTGX,ALF,1:;
6. Reset BSC OMU
ZUSU:OMU:C=DSK,;

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

31 (55)
24-Apr-2014

BSC FALLBACK COPYING ERROR

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

32 (55)
24-Apr-2014

BSC FALLBACK COPYING ERROR


2663-DUMPING ERROR IN DATABASE MANAGER
2393-FALLBACK COPYING TERMINATED IN ERROR

RESULT: BSC Fall back will not be possible or terminated if any of these alarm is present in BSC.
Precaution: Need to be execute the activity under senior supervision in night hours with proper outage approval
as per process.

PROCEDURE
1) First check WDU state using below command. if both WDU reflect as WO-BU then execute this process
otherwise follow the WDU troubleshooting document.
ZISI::WDU;
2) If both WDU are WO-BU, then check ZDBD output to verify disk consistency.
Example:
ZDBD:OMU;
BSC3i

BSC78BHU

2012-01-24 13:19:38

DATA OCCUR- DUMPING CONSIST ALLOWED


LOG WRITE LOG
EMPTY FREE
BASE RENCE OR
DISK OPERATIONS WRITE ERROR EMPTY ERROR DISKLOG
NAME
LOADING
TO LOG COUNT COUNT COUNT COUNT BUFFERS
PDDATA 0
ILDATA 0

NONE
NONE

W0

WRITE,MOVE

45

W0, W1 WRITE,MOVE

120

OEDATA 0

NONE

W0, W1 WRITE,MOVE

30

EQUIPM 0

NONE

W0, W1 WRITE,MOVE

600

BSDATA 0

NONE

W0, W1 WRITE,MOVE

45

COMMAND EXECUTED

NOTE: Here PDDATA is not updating on WDU-1. Hence Fallback is not possible or terminating. It may be
possible that other database has the same issue, same process needs to be executed to resolve the fault. I have
seen that this problem will occur mostly in respect of BSDATA & PDDATA.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

33 (55)
24-Apr-2014

3) Now Check the output of below command and verify database State & Sub state.
ZDBS:PDDATA,0:;
ZDBS:BSDATA,0:;
ZDBS:ILDATA,0:;
ZDBS:OEDATA,0:;
ZDBS:EQUIPM,0:;
Example: (Only for PDDATA, check for others also)
MAIN LEVEL COMMAND <___>
< DBS:PDDATA,0;
LOADING PROGRAM VERSION 14.15-0
BSC3i

BSC78BHU

2012-01-24 13:09:34

DATABASE OCCURRENCE WO/SP

STATE

PDDATA

WO

DUMPING

PDDATA

SP

NORMAL

MEMORY UPDATES
PREVENTED
NO

DISK UPDATES
PREVENTED
NO

SUBSTATE
DUMPING DATABAS
NORMAL

TRANSACTION
OVERFLOW
NO

BACK UP
IS ON
NO

LOGBUF ID
000F
LATEST TRANSACTIONS:
REQUESTOR`S COMPUTER REQUESTOR`S FAMILY TRANSACTION ID TRANSACTION PHASE
4505
0295
008D
EXEC SUCCESS
4505
0295
008D
EXEC SUCCESS
4505
01B5
0094
EXEC SUCCESS
4505
01B5
0093
EXEC SUCCESS
4505
0295
008C
EXEC SUCCESS
4505
06B7
00E7
EXEC SUCCESS
4505
0295
008D
EXEC SUCCESS
4505
0295
008D
EXEC SUCCESS
COMMAND EXECUTED

NOTE: Here, it is clear that the state (highlighted in above output) of PDDATA is in DUMPING state although
there is no dumping in progress. Hence, when we try for FALLBACK it terminated as dumping is not possible
because PDDATA is already in DUMPING state. It should be in NORMAL state and we will set as normal in
onwards procedure. Also check for other databases for the same.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

34 (55)
24-Apr-2014

4) Execute below command.


ZDUR:;
Output
BSC3i BSC78BHU
2012-01-24 12:55:02
RESUMING FILE UPDATES TO DISK
UNIT
STATE
-----------------OMU
NOT PREVENTED
COMMAND EXECUTED
5) Execute below command (Usually end with error)
ZDBR:PDDATA,0:DISK:;
Output
/*** DX ERROR: 10309 ***/
/*** REQUESTED TASK ALREADY DONE ***/
6) Restart the given process in Spare MCMU followed by MCMU code loading restart. (Execute this step if
2663 alarm is present in BSC)
ZDDS:MCMU,<SP MCMU>;
MAN>ZOKR:1B5
MAN>ZOKR:6B7
Wait for 5 min and perform MCMU code loading restart and repeat the same for another MCMU by
making it spare.
7) Execute below command in OMU using service terminal.
ZDDS:OMU;
-->Change plan database state to CLEAR in active database (BSDATA):
ZDDS:;
ZLE:Q,DAEMONGX
ZQD:6390000,4505,19B
ZQM:412,T:00,XD5CEF,XD5CEF,XD5CEF
Wait for 5 mins
For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

35 (55)
24-Apr-2014

-->Change at last plan database state in plan database (PDDATA):


ZQD:BA6002A,4505,6AE
ZQM:231,T:00,XD5CEF,XD5CEF,XD5CEF
8) Restart OMU with code loading
ZUSU:OMU:C=DSK;
9) Now check for database state and disk consistency using step-1 & 2. If found ok go to step-17 (Skip step10, 11, 12, 13, 14, 15 & 16)
10) If Still issue not resolved delete the Delete the DBA*.IMG and DBINFOGX.IMG files from LFILES
directory from BOTH DISKS (ZIWD).
ZIWD::WSB,NODEF:<ROOT_DIRECTORY>,LFILES:DBI%,IMG;
ZIWD::WSB,NODEF:<ROOT_DIRECTORY>,LFILES:DBA%,IMG;
11) Restart the DBSMAN process with below service terminal command
ZDDS;
ZODR:142
ZE
12) Wait for the system creates DBA*.IMG and DBINFOGX.IMG files on both disk (about 5-10 min)
13) Dump all the database from the memory to disks (ZDBC)
ZDBC:PDDATA,0:;
(Use the same cmd for other databases also)
14) Resume memory updates (ZDBR)
15) Give OMU restart with

ZUSU:OMU:C=DSK;

16) Check the status of all data base(ZDBS) whether they are in normal state or no
17) Now take valid Fallback and check FB as well as BU consistency using below commands.
ZWKS:MODE=FULL,NAME=FB011211,DIRE-FB011211:;
ZWQB:NAME=directory_name:FORM=FAILED:;

Note: Also check for any service affecting alarm regarding BSC. In case of any major/critical alarms
observed escalate same to their SPOC.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

36 (55)
24-Apr-2014

BHARTI FM-BSS
EMB TROUBLESHOOTING

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

37 (55)
24-Apr-2014

EMB TROUBLESHOOTING
A) Check logs of port & other setting
Here, I consider EMB-0 faulty.

ZYFE:ALL; ----- ZYFF:INQ:: ---------ZW6I::::;

B) Perform jack out & jack in of ESB card of MCMU-0


C) If still fails the do the following activity (EBSTER Testing):
1- Make EMB-0 in TEST mode.
2- Perform the EBSTER testing of EMB-0.
ZDDS;
ZLP:1,EBS;
Z1
00:EBS> AT:0x007F,0
The O/P should be like this:
Message sent Received test messages using EMB-0 from following units:
============================================================================
0000, 0004, 0005, 0030, 0031, 0032, 0033, 0034, 0035, 0036, 0037, 0038, 0039, 003A
3- Check the MAC addresses of all computer units.
00:EBS> A:0x000:0xFFFF
The O/P should be like:
EMB-0 OK, EMB-1 OK
Unit MAC addr 0 Mac addr 1 MB CID EMB0 EMB1 CPU SCD
=======================================================================
0000 02:00:00:80:00:20 02:00:00:80:00:30 0000 0000 OK OK CP816-A OK
0004 02:00:00:80:01:20 02:00:00:80:01:30 0001 0001 OK OK CP816-A OK
0005 02:00:00:80:02:20 02:00:00:80:02:30 0002 0002 OK OK CP816-A OK
0030 02:00:00:80:03:20 02:00:00:80:03:30 0003 0003 OK OK CP816-A OK

D) Secondly check ESB configuration via local login in ESB card through Serial Port
Login to the serial port of the ESB PIU of MCMU 0 after taking MCMU 0 to SE-NH Mode and EMB 0 to
TE-EX Mode and reload ESB card.
Password:nokia
Ena
Reload
Y
Diagnose the EMB-0.
E) Verify CPU jumper setting
For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

38 (55)
24-Apr-2014

SW1 switch settings


Switch 1
1-12
2-11
3-10
4-9
5-8
6-7

Setting
Off
Off
Off
Off
Off
Off

Meaning
Interchangeability code bit 3
Interchangeability code bit 2
Interchangeability code bit 1
Interchangeability code bit 0
Not in use
Message Bus Interface (MBIF) status: OFF = MBIF in use (bit D3 in register 104h reads 0).
In NE installations, when EMB is used, thissetting must be ON = MBIF not in use.

** For interchangeability Code (ICC) setting please refer Jumper setting Document.

F) Replace ESB card with new one and configure the same.
G) Replace CPU card
H) Need to verify below cabling as per requirement & Fault Description
Note:
450 should be connected below cable no. 451 and 452 should be connected below cable no. 453 in ESB26

Cable No

CABLE FROM

CABLE TO

Type

Use

CHES012
CHES023
CHES020
CHES017
CHES027
CHES024
CHES021

EMB
EMB
EMB
EMB
EMB
EMB
EMB

BSCC_430
BSCC_433
BSCC_434
BSCC_435
BSCC_436
BSCC_437
BSCC_438

FU
MCMU 0
MCMU 0
MCMU 0
MCMU 0
MCMU 0
MCMU 0
MCMU 0

Position
2.0B 02.2X
2.0B 02.2R
2.0B 02.2P
2.0B 02.2N
2.0B 02.2L
2.0B 02.2J
2.0B 02.2G

FU
OMU
BCSU 0
BCSU 1
BCSU 2
BCSU 3
BCSU 4
BCSU 5

Position
2.6B 10.1A
3.0B 10.1A
3.4B 10.1A
3.8B 10.1A
4.0B 10.1A
4.4B 10.1A
4.8B 10.1A

BSCC_439
BSCC_442
BSCC_443
BSCC_444
BSCC_445
BSCC_446
BSCC_447

MCMU 1
MCMU 1
MCMU 1
MCMU 1
MCMU 1
MCMU 1
MCMU 1

2.3B 02.2X
2.3B 02.2R
2.3B 02.2P
2.3B 02.2N
2.3B 02.2L
2.3B 02.2J
2.3B 02.2G

OMU
BCSU 0
BCSU 1
BCSU 2
BCSU 3
BCSU 4
BCSU 5

2.6B 10.1P CHES010 EMB


3.0B 10.1P CHES021 EMB
3.4B 10.1P CHES018 EMB
3.8B 10.1P CHES015 EMB
4.0B 10.1P CHES025 EMB
4.4B 10.1P CHES022 EMB
4.8B 10.1P CHES019 EMB

BSCC_450
BSCC_451

MCMU 0
MCMU 0

2.0F 02.ETH26 MCMU0


2.0F 02. ETH25 MCMU1

BSCC_452
BSCC_453

MCMU 1
MCMU 1

2.3F 02.ETH26
2.3F 02.ETH25

2. 0B 07.1A CHUX035
2. 3B 07.1A CHUX033

EMB 1)
EMB 1)

MCMU 0 2. 0B 07.1P CHUX025


MCMU 1 2. 3B 07.1P CHUX023

EMB 1)
EMB 1)

Position

ID Name

FU

Use

Note

2.6B 10.1G

C108719

ADMOD00

OMU

EMB address

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

2.6B 10.1J
2.0B 07.1G
2.0B 07.1J
2.3B 07.1G
2.3B 07.1J
3.0B 10.1G
3.0B 10.1J
3.4B 10.1G
3.4B 10.1J
3.8B 10.1G
3.8B 10.1J
4.0B 10.1G
4.0B 10.1J
4.4B 10.1G
4.4B 10.1J
4.8B 10.1G
4.8B 10.1J

39 (55)
24-Apr-2014

C108719
C108691
C108719
C108692
C108719
C108703
C108585
C108704
C108585
C108705
C108585
C108706
C108585
C108707
C108585
C108708
C108585

ADMOD00
ADMOD04
ADMOD00
ADMOD05
ADMOD00
ADMOD16
ADMOD01
ADMOD17
ADMOD01
ADMOD18
ADMOD01
ADMOD19
ADMOD01
ADMOD20
ADMOD01
ADMOD21
ADMOD01

OMU
MCMU 0
MCMU 0
MCMU 1
MCMU 1
BCSU 0
BCSU 0
BCSU 1
BCSU 1
BCSU 2
BCSU 2
BCSU 3
BCSU 3
BCSU 4
BCSU 4
BCSU 5
BCSU 5

For internal use only Nokia Solutions and Networks

EMB Address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address
EMB address

For internal use only

Bharti FM-BSS

40 (55)
24-Apr-2014

MB TROUBLESHOOTING

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

41 (55)
24-Apr-2014

MB (Message Bus) Understanding


The MB is the physical connection between the computer units of the network element. It is controlled by
the Message Bus Interface plug-in units (MBIF-B) located in every computer unit.
MB used by the BSC3i 660 which use a shared bus for communication.
The duplicated Message Bus has a transfer rate of 32 Mb/s. It is controlled by the Message Bus Interface
plug-in unit (MBIF-B), which also acts as a bi-directional interface between a microcomputer and the 16bit parallel Message Bus.
The path of the message bus through the computer units is shown in Figure Message bus (MB).

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

42 (55)
24-Apr-2014

The MBIF-B is connected to the CPU of the microcomputer unit via the PCI bus and to the MBIF-B plug-in
units of the other microcomputer units in the exchange via the MB. The MBIF-Bs receive their basic
timing signals from the Clock Equipment (CLS).

The figure shows the connection principle of the microcomputer units to the duplicated Message Bus
(MB) whose maximum length is about 50 m. Both MBs are normally in use (active) simultaneously. One
MB is chosen with the software as the active bus along which all call control messages are sent to make
sure that their order is retained at the receive end. The other bus can be used to send e.g. various loading
messages. If either MB becomes faulty, the entire load is transferred to the intact MB. No hardwarebased changeover signal is associated with the selection of the MB in the MBIF-B plug-in units.

Make sure about the MB state & MCMU state both should be same in case of any troubleshooting related
activity such as MCMU/EMB fault rectification activity.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

43 (55)
24-Apr-2014

MB (Message Bus) TROUBLESHOOTING


A) The below four points to be taken care during the MB troubleshooting
1) MBIF-B PIU. (Placed in all the Computer Units of BSC)
2) MB back panel interconnected cables.
3) MBADR modules. (Placed in back panel of all the MBIF PIU.)
4) TRM9B terminators. (Placed in the starting & ending unit in a MB path i.e. BCSU-0 & MCMU-0)
B) In case of a MB failure scenario u cant find the affected computer unit Physically, however we have a mml
command to find out the fault. For example - Assuming a fault in MB1
ZDDS:OMU;
00-MAN>ZSMTAC:1,00,04,05,30,31,32,33,34,35,36:1000,1000 (MB1 Working or in Test)
(Repeat the above process with all the computer units)
Output Like this

TEST ROUND: 1
COMP DATA_ERR TIME_OUT REC_ERR LAST ERROR STATUS
0000 00000000 00000000 00000000
0004 00000000 00000000 00000000
0005 00000000 00000000 00000000
0030 00000000 00000000 00000000
0031 00000000 00000000 00000000
0032 00000000 00000001 00000000 TIME OUT
0033 00000000 00000000 00000000
0034 00000000 00000001 00000000 TIME OUT
0035 00000000 00000001 00000000 TIME OUT
0036 00000000 00000000 00000000
TOTAL 00000000 00000003 00000000
TEST ROUND: 2
COMP DATA_ERR TIME_OUT REC_ERR LAST ERROR STATUS
0000 00000000 00000000 00000000
0004 00000000 00000000 00000000
0005 00000000 00000000 00000000
0030 00000000 00000000 00000000
0031 00000000 00000000 00000000
0032 00000000 00000002 00000000 TIME OUT
0033 00000000 00000000 00000000
0034 00000000 00000002 00000000 TIME OUT
0035 00000000 00000002 00000000 TIME OUT
0036 00000000 00000000 00000000
TOTAL 00000000 00000006 00000000

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

44 (55)
24-Apr-2014

C) To start with always check for the alarms related to MB failure & which unit has caused the alarm.
<HIST> BSC67CIH
BCSU-2
* DISTUR MB-1
SUPPRO
1016 MB INTERFACE FAILURE
02 01

SWITCH 2011-09-27 01:08:15.22

<HIST> BSC67CIH
BCSU-2 SWITCH 2011-09-27 01:08:21.84
* DISTUR MB-1
DPALAR
*RECOV*
1598 UNIT FOUND FAULTY BY ALARM SYSTEM
FFFF FFFF 00001016 00000000 00000000 00000000 00000000 00000000
<HIST> BSC67CIH
OMU
SWITCH 2011-09-27 01:08:21.86
NOTICE MB-1
RCXPRO
0691 AUTOMATIC RECOVERY ACTION
SP-EX TE-EX 0000 0002 7889 00001016 00001598 00000000
D) Post changing the unit state to SE-NH & concerned MB to SE-NH power off the Comp unit & check the MBIF-B
PIU jumper settings & the back panel pins for any bent.
E) If there is only one unit which fails, replace the diagnosed MBIF. Also terminator or cable can be faulty.
F) If units like in above output (32, 34, 35), there is probably fault in the first faulty unit in the chain (BCSU-2). The
bus goes in following chain in BSC3i (660 TRX).
MCMU-0, MCMU-1, BCSU-6, OMU, BCSU-1, BCSU-2, BCSU-5, BCSU-4, BCSU-3, BCSU-0
G) You can also see from BCSU service terminal startup the MB ADDR are correct:
MB 00: MBIF-B, MB ADDR 30, FREQ 2MHZ, TRANS.FREQ 16MHZ, WIDTH 16BIT
MB 01: MBIF-B, MB ADDR 30, FREQ 2MHZ, TRANS.FREQ 16MHZ, WIDTH 16BIT
H) Also check the MBADR module position,TRM9B terminator & the MB back panel cables.
I) Irrespective of the diagnosis results there may be the Time Out scenarios in ZSMTAC command & thus needs to
replace the MBIF piu,the corresponding MB cables & MBADR modules one by one for eradicating the message
time out scenarios.
J) If several units are faulty you can also do the pin voltage measurement since there exists more problems on
MB-bus thus pin measurement is required.

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

45 (55)
24-Apr-2014

Cabling Details:
Equipping

CABLE FROM

No

FU

CABLE TO

Position

FU

Position

Type

Use

BSCC_050

MCMU 0

2.0B 05.1N

MCMU 1

2.3B 05.2A

CHX005

MB

BSCC_051

MCMU 0

2.0B 05.1T

MCMU 1

2.3B 05.2G

CHX005

MB

BSCC_052

MCMU 0

2.0B 06.1N

MCMU 1

2.3B 06.2A

CHX005

MB

BSCC_053

MCMU 0

2.0B 06.1T

MCMU 1

2.3B 06.2G

CHX005

MB

BSCC_054

MCMU 1

2.3B 05.1N

BCSU 6

1.8B 08.1N

CHX007

MB

BSCC_055

MCMU 1

2.3B 05.1T

BCSU 6

1.8B 08.1T

CHX007

MB

BSCC_056

MCMU 1

2.3B 06.1N

BCSU 6

1.8B 09.1N

CHX007

MB

BSCC_057

MCMU 1

2.3B 06.1T

BCSU 6

1.8B 09.1T

CHX007

MB

BSCC_062

OMU

2.6B 08.2A

BCSU 1

3.4B 08.1N

CHX005

MB

BSCC_063

OMU

2.6B 08.2G

BCSU 1

3.4B 08.1T

CHX005

MB

BSCC_064

OMU

2.6B 09.2A

BCSU 1

3.4B 09.1N

CHX005

MB

BSCC_065

OMU

2.6B 09.2G

BCSU 1

3.4B 09.1T

CHX005

MB

BSCC_066

BCSU 1

3.4B 08.2A

BCSU 2

3.8B 08.1N

CHX005

MB

BSCC_067

BCSU 1

3.4B 08.2G

BCSU 2

3.8B 08.1T

CHX005

MB

BSCC_068

BCSU 1

3.4B 09.2A

BCSU 2

3.8B 09.1N

CHX005

MB

BSCC_069

BCSU 1

3.4B 09.2G

BCSU 2

3.8B 09.1T

CHX005

MB

BSCC_070

BCSU 2

3.8B 08.2A

BCSU 5

4.8B 08.1N

CHX004

MB

BSCC_071

BCSU 2

3.8B 08.2G

BCSU 5

4.8B 08.1T

CHX004

MB

BSCC_072

BCSU 2

3.8B 09.2A

BCSU 5

4.8B 09.1N

CHX004

MB

BSCC_073

BCSU 2

3.8B 09.2G

BCSU 5

4.8B 09.1T

CHX004

MB

BSCC_082

BCSU 3

4.0B 08.1N

BCSU 0

3.0B 08.1N

CHX45C

MB

BSCC_083

BCSU 3

4.0B 08.1T

BCSU 0

3.0B 08.1T

CHX45C

MB

BSCC_084

BCSU 3

4.0B 09.1N

BCSU 0

3.0B 09.1N

CHX45C

MB

BSCC_085

BCSU 3

4.0B 09.1T

BCSU 0

3.0B 09.1T

CHX45C

MB

BSCC_078

BCSU 4

4.4B 08.1N

BCSU 3

4.0B 08.2A

CHX005

MB

BSCC_079

BCSU 4

4.4B 08.1T

BCSU 3

4.0B 08.2G

CHX005

MB

BSCC_080

BCSU 4

4.4B 09.1N

BCSU 3

4.0B 09.2A

CHX005

MB

BSCC_081

BCSU 4

4.4B 09.1T

BCSU 3

4.0B 09.2G

CHX005

MB

BSCC_074

BCSU 5

4.8B 08.2A

BCSU 4

4.4B 08.2A

CHX005

MB

BSCC_075

BCSU 5

4.8B 08.2G

BCSU 4

4.4B 08.2G

CHX005

MB

BSCC_076

BCSU 5

4.8B 09.2A

BCSU 4

4.4B 09.2A

CHX005

MB

BSCC_077

BCSU 5

4.8B 09.2G

BCSU 4

4.4B 09.2G

CHX005

MB

BSCC_058

BCSU 6

1.8B 08.2A

OMU

2.6B 08.1N

CHX005

MB

BSCC_059

BCSU 6

1.8B 08.2G

OMU

2.6B 08.1T

CHX005

MB

BSCC_060

BCSU 6

1.8B 09.2A

OMU

2.6B 09.1N

CHX005

MB

BSCC_061

BCSU 6

1.8B 09.2G

OMU

2.6B 09.1T

CHX005

MB

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

46 (55)
24-Apr-2014

Terminator is located at the end of MCMU-0 & BCSU-0.


Position

ID

Name

FU

Use

2.0B 05.2A

C100810

TRM9B

MCMU 0

Terminator of MB

2.0B 06.2A

C100810

TRM9B

MCMU 0

Terminator of MB

3.0B 08.2A

C100810

TRM9B

BCSU 0

Terminator of MB

3.0B 09.2A

C100810

TRM9B

BCSU 0

Terminator of MB

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

47 (55)
24-Apr-2014

BSC Fallback & MO Disk (FDU) Backup

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

48 (55)
24-Apr-2014

STEP TO TAKE BSC FALLBACK


1.2 Detailed step by step procedure to take BSC Fallback on WDU
1) Open New logs for BSC
2) Check the correct BSC using below command
ZQNI:;
3) Check for others login (Make sure no activity should be carried out in this BSC)
ZQNS:;
4) Check for critical alarms in BSC
ZAHO;
5) Check the status of SOMAFI (How many packages are created in BSC)
ZWQO:CR;
6) If there are 8 packages already created in SOMAFI, deleted one old UT package
ZWQD:NAME=<ut_package>:DIRE,PRINTS;
7) Now check consistency of BU package
ZWQB:STAT=BU:FORM=FAILED;
NOTE: Consistency of all files in both disks should be ok. In case of abnormal output escalate the same
to your SPOC
8) If consistency found ok, take BSC fallback (on WDU)
NOTE: The fallback build can only be made from the build that has the BU status
ZWKS:MODE=FULL,NAME=<package name>,DIRE=<package directory>;
Suppose we are taking fallback on 28-Feb-14 (FB280214) then the command is like below
ZWKS:MODE=FULL,NAME=FB280214,DIRE= FB280214;
9) Check the status of Fallback copying
ZWKI;
Note: Execute the same commad till the message,*/NoFall back copying in progress/* will appear
10) After completing Fallback Check the Consistancy of FB
ZWQB:STAT=FB:FORM=FAILED;

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

49 (55)
24-Apr-2014

1.3 Detailed step by step procedure to take BSC backup on FDU


11) Check whether FDU or UMS is working or not.
ZISI;
12) Create all directories and Subdirectories on FDU or UMS (I am considering here F0-FDU0)
ZIWL::F0,NODEF::<New package name>,FF,,AA;
ZIWL::F0,NODEF::FB280214,FF,,AA;
Create subdirectories
ZIWL::F0,NODEF:FB280214:LFILES,900,,AA;
ZIWL::F0,NODEF:FB280214:BLCODE,900,,AA;
ZIWL::F0,NODEF:FB280214:MMDIRE,900,,AA;
ZIWL::F0,NODEF:FB280214:SCMANA,FF,,AA;
ZIWL::F0,NODEF:FB280214:ASWDIR,900,,AA;
13) To display the contents of MO disk
ZIWX::F0,NODEF:FB280214:%%;
ZIWX::WS,NODEF::%,%;
ZIWX::WS,NODEF:FB280214:%%;
(Use either Step-14 or Step-15 to copy data from WS to MO disk)
14) Copy contents from WS to MO disk. Copy file from source(WS) to destination(MO)
For LFILES:
ZIWY:S:UNIT=OMU,PATH=/FB280214/LFILES,DRIVE=WDU-S;
ZIWY:D:UNIT=OMU,PATH=/FB280214/LFILES,DRIVE=FDU-N0;

Create Source of Copy


Create Desdination

Copy Source to Destination


ZIBC;
Y
For BLCODE:
ZIWY:S:UNIT=OMU,PATH=/FB280214/BLCODE,DRIVE=WDU-S;
ZIWY:D:UNIT=OMU,PATH=/FB280214/BLCODE,DRIVE=FDU-N0;
ZIBC;
Y
For MMDIRE:
ZIWY:S:UNIT=OMU,PATH=/FB280214/ MMDIRE,DRIVE=WDU-S;
ZIWY:D:UNIT=OMU,PATH=/FB280214/ MMDIRE,DRIVE=FDU-N0;
ZIBC;
Y
For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

50 (55)
24-Apr-2014

For SCMANA:
ZIWY:S:UNIT=OMU,PATH=/FB280214/ SCMANA,DRIVE=WDU-S;
ZIWY:D:UNIT=OMU,PATH=/FB280214/ SCMANA,DRIVE=FDU-N0;
ZIBC;
Y
For ASWDIR:
ZIWY:S:UNIT=OMU,PATH=/FB280214/ ASWDIRE,DRIVE=WDU-S;
ZIWY:D:UNIT=OMU,PATH=/FB280214/ ASWDIR,DRIVE=FDU-N0;
ZIBC;
Y
15) Another process to copy content from WS to MO (Copy the entire FB package instead of
Subdirectories)

ZIWX::F0,NODEF::%,%,;
ZIWL:,OMU:F0,NODEF:: FB280214,,,AG;
ZIWY:S:UNIT=OMU,DRIVE=WDU-S,PATH=/ FB280214,:;

//Define Source point

ZIWY:D:UNIT=OMU,DRIVE=FDU-N0,PATH=/ FB280214,;

//Define Destination point

ZIBC:,,,,,,,,,DIR::;

//Copy source to destination

16) Check content of MO disk


ZIWX::F0,NODEF:FB280214:%,%;

1.4 Some other important commands may used during FDU troubleshooting
1. To reinitialize directories on MO (FDU) disk
ZIWK::F0,::;
2. Format MO disk if requierd (not recommended)
ZIWI::<drive>,<format>,<partition table>;

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

51 (55)
24-Apr-2014

BSC Login via OMU (CPU J7 Port)

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

52 (55)
24-Apr-2014

BSC Login through CPU J7 Port


First Connect RJ45 to CPU J7 PORT & DB9 to laptop port (use BSC login cable) and press ENTER.
1) Then system will ask for user name & password
2) Provide user name & password
a) First try with use user id SYSTEM & Password SYSTEM, if system say unauthorized
b) Then use user id & password of 2nd line team of respective circle team.
3) Then System will show
WELCOME TO SERVICE TERMINAL DIALOGUE
00- MAN>
4) Create extension
00-MAN> L:2
00-MAN> ZLP:2,VIMMALGX
00-MAN> 2
00-VIM> C:2
Connected. (vtermd server hand is 1)

5) ENTER USERNAME < GNFMBT


ENTER PASSWORD < ******

BSC3i

B23MRW

2014-03-28

13:39:30

WELCOME TO THE DX 200 SERIES DIALOGUE

MAIN LEVEL COMMAND <___>

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

53 (55)
24-Apr-2014

PCU Pooling Concept/Troubleshooting

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

54 (55)
24-Apr-2014

PCU Pooling Troubleshooting


Before proceeding to troubleshoot lets clear some basic point about PCU Pooling.
1) PCU2 Pooling feature introduces the Packet Service Entity (PSE) concept. PSE is a logical concept, which
covers several PCU PIUs in BSC. All PCUs in PSE are serving the same NSE
2) Logical network configuration is separated from HW configuration as Gb interface is configured to NSE
only and DAPs and Segments are attached to PSE instead of PCU
3) When we adds a new PCU into PSE, the system automatically configures Gb interface to new PCU and
then allocates DAPs and Segments to new PCU based on each Segments (E)GPRS load. The operator does
not need to do any changes to the logical network configuration in BSC and either in SGSN
4) PCU2 Pooling is optional feature (On/Off), managed by Licensing
5) PCU2 Pooling feature is implemented in BSC only to PCU2 and when IP is used as transport method on the
Gb interface.
6) Minimum configuration: two PCU can form a PSE
7) Maximum configuration: 50 PCUs in one PSE
8) In case of Multipoint Gb, there is several NSEs in PSE. Each NSE covers PSEs all PCUs
9) IP configuration is static or dynamic in NSE. In case of Multipoint Gb, both IP configurations can be used
parallel in PSE. However type of IP configuration in one NSE has to be same
10) All PCUs in PSE has to use same IP version (IPv4 or IPv6) in NSE. In case of Multipoint Gb, both IP versions
can be used parallel in PSE. However type of IP version in one NSE has to be same
11) IP version 4 only is used on the Inter-PCU LAN interface
12) PCU2, Gb over IP and PCU2 pooling licenses must be activated.

Advantages of PCU Pooling


1) Easy way to increase (E)GPRS capacity in the network, in BSC
2) Savings in configuration costs (no modification to logical network configuration in the BSC and neither in
the SGSN)
3) Abis and Gb resources are shared more efficiently and dynamically between PCUs in NSE
4) (E)GPRS load is shared dynamically between PCUs within the PSE when the operator adds a new PCU into
the PSE or reallocates PSE configuration

For internal use only Nokia Solutions and Networks

For internal use only

Bharti FM-BSS

55 (55)
24-Apr-2014

Now go through the below steps one by one to troubleshoot the problem
1) Check the value of the Packet Control Unit (PCU2) Pooling feature state
ZW7I:FEA,FULL:FEA=70;
2) If necessary, change the Packet Control Unit (PCU2) Pooling feature state to ON
ZW7M:FEA=70:ON;

(Use this command under SPOC/TL supervision only)

3) Verify logical PCU definition in PCU pooling using ZQKB:;


4) If inter PCU connections are missing please add the same using below steps. To understand the concept
lets consider BCSU-0 and same must be defined for all BCSU.
ZQKC:BCSU,0:PCU2D,3:172.27.132.70,32:172.27.132.77:LOG:;
Here 172.27.132.70, defines the IP for BCSU-0 PCU-4 i.e inter connectivity between the logical PCUs of BCSU-0
(PCU-3- PCU-4) and 172.27.132.77 defines the IP used for Gateway purpose and it should be the IP of next
working BCSU i.e BCSU-1 PCU-3.
Same should be defined for other logical PCU in all the BCSU.
NOTE: Logical mapping required where PCU2_D is in use. It is not required in case of PCU_B/PCU2_E.
5) Check Ping response
a) Ping PCU to ESB
b) Ping PCU to GW
c) Ping ESB to PCU
d) Ping ESB to SGSN
e) SGSN to PCU

6) Perform GENA/EGENA Toggle, DAP deletion & creation, NSEI change or NSEI reset (night hours only with
proper outage approval) at BSC end as well as SGSN.
7) Off load the problematic NSEI and perform PCU deletion & Creation using below Steps.
a) Remove PCU from PSE
ZFXF:R:BCSU=0,PCU=4,PSEI=0::;
b) Add PCU to PSE
ZFXF:A:BCSU=0,PCU=4,PSEI=0::;
8) If still not resolved perform BCSU swithover.

For internal use only Nokia Solutions and Networks