Sunteți pe pagina 1din 8

TEMPERATURE TRANSMITTER

1. Precision Digital PD312 Configurator


Model PD312 with Pt100 RTD Sensor
Universal Input : RTD, TC, Ohm & mV
Operating Temperature : -40 to 75C
Input

: Universal RTD, TC,


Resistance, or Voltage
Output
: Two-wire 4-20 mA scalable
Accuracy & Input Ranges : 0.08% of span typical, see
table on page 10 for details
Temperature Drift
: RTD 0.004C/C
TC 0.03C/C
Display PV
: 0.3" (8 mm) 5-digit LCD,
Input & Units: 0.2" (5 mm)
Bargraph
: 52 segments with 2%
resolution
Decimal Point PV
: 1 or none mA, %: Up to 3
decimals
Backlight
: Loop-powered, always on
Programming Method
: PDA8302 HART modem and
PC software or field handheld HART communicator
Under Range
: 3.8 mA
Oveer Range
: 20.5 mA
Sensor Break
: Selectable 3.6 mA Low Alarm or 22 mA High Alarm
Response Time
: 1 second
Long Term Stability
: Better than 0.05% per year
Start Up Time
: Less than 5 seconds

2. PT100 4-20mA Temperature Transmitter


REF: KI-KAL23P
PT100 4-20 mA
Technical Data
Input
Sensor Range
Minimum Span
Output
Accuracy

:
:
:
:
:

PT100 BS EN 60751 100 ohms atC


-200 to +850C
20C
3.8 to 22mA Max.
+/- 0.1C +/-0.1% rdg over -100 to +500C

Indication
Supply
Ambient
Loop Resistance
Open Circuit

:
:
:
:
:

+/- 0.2C +/-0.2% rdg over -200 to +850C


Red LED indicates operation and sensor out of range.
8V TO 30V. Reverse connection protected.
0 to 70C operating -40 to 70C storage
800r at 24V.
Upscale 22mA.

3. RTD In-Head Temperature Transmitter TX12


SPECIFICATIONS :
Input
Sensor Type
Sensor Range
Sensor Connection
Minimum Span
Linearisation

: Pt100 100 @ 0C 2 or 3 Wire


: -200 to 850C (-328 to 1562F)
: Screw terminal
: 25C (77F)
: BS EN 60751(IEC 751)
standard/JISC 1604
Measurement Accuracy
: 0.1C 0.05% of reading
Thermal Drift
: 25 ppm/C
Excitation Current
: <200 uA
Lead Resistance Effect
: 0.002C/
Maximum Lead Resistance : 20 per leg
Output
Output Type
Output Range
Output Connection
Maximum Output
Minimum Output
Accuracy
Loop Voltage Effect
Thermal Drift
Maximum Output Load

: 2 wire, 4 to 20 mA current
loop
: (4.0 to 20.0) mA
: Screw terminal
: 21.5 mA (in high burnout condition)
: 3.8 mA (in low burnout condition)
: (mA output /2000) or 5 uA (whichever is the greater)
: 0.2 uA/V
: 1 uA /C
: [(Vsupply-10)/20]K

General Specifications
Update Time
Response Time
Start Up Time
Warm-Up Time
Power Supply
Environmental

:
:
:
:
:

500 mS
1 second
4 seconds (I out < 4 mA during start up)
1 minute to full accuracy
10 to 30 Vdc

Ambient Operating Range


: -40 to 85C (-40 to 185F)
Ambient Storage Temperature : -50 to 90C (-58 to 194F)
Ambient Humidity Range
: 10 to 90% RH non condensing

PRESSURE TRANSMITTER
1. High Accuracy Pressure Transmitters WIKA P-10
0.05% BFSL Accuracy, 0.025% BFSL Optional
No additional temperature error between 32 to 122 F
Microprocessor based for accuracy and performance
Vacuum to 15,0000 PSIG
4-20 mA or 0-5 Vdc Outputs, RS232
10-30 Vdc Supply Voltage
316

and PH17-4 SS Wetted Parts

2. KH3351 Smart Differential Pressure Transmitter


Accuracy
: Measured accuracy: 0.2% to0.25% FS, Digital
Stability
: 5 years of 0.25%
Power supply
: 12V to 45VDC, 24VDC
default
Range
: -100Pa to 40Mpa, Range
ratio: 1:1
Linear output
: 0.075%0.1%, range
ratio:1:1
Turn on time
: 0.2second
Damping adjustment : 0-32 second
Fill Fluid
: Sillicon/ Fluorine Oil
Vibration Effect
: 0.05% of URL per g to 200
in any axis
Output Signal
: 4-20mA current output HART( RS485 port with
communication keyboard, without hand held communicator)
Power Connection
: cable, air plug, Hirschman plug
Process Connections : 1/2NPT, 1/4NPT
Ambient temperature : -40 to 85
Ambient Humidity
: 0-95%RH
Humidity limits
: 0-100%RH relative humidity

3. Yokogawa EJA510 pressure transmitter

EJA510A / EJA530A Direct Mount Type Absolute Pressure and Gauge Pressure
Transmitter (Measurement values below are in absolute for EJA510A)

Range :
A Capsule = 0 to 200 kPa (0 to 29 psi)
B Capsule = 0 to 2 Mpa (0 to 290 psi)
C Capsule = 0 to 10 Mpa (0 to 1450 psi)
D Capsule = 0 to 50 Mpa (0 to 7200 psi)
Output :
4 to 20 mA DC or FOUNDATIO fieldbus or PROFIBUS PA
2-wire system with digital communication
Supply voltage :
BRAIN and HART : 10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus : 9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for
FISCO model)
Maximum overpressure :
A capsule = 4 Mpa (580 psi)
B capsule = 4 Mpa (580 psi)
C capsule = 20 Mpa (2900 psi)
D capsule = 60 Mpa (8500 psi)

LEVEL TRANSMITTER
1. Rosemount 2051 Level Transmitter
Product Configurations 2051L with flush and
extended diaphragm seals.
1199 Diaphragm Seal
optional.
Long Term Stability
0.1% of URL for 2 years
Output
4-20mA HART,
FOUNDATION fieldbus,
1-5Vdc HART Low Power
Reference Accuracy
0.075% of span
Rangedown:
100:1

2. Smart GWR Level Transmitter ALT6100

3. Flange Mounting Liquid Level Transmitters

Model Number : LV38

FLOW TRANSMITTER

1. SMV 3000 Flow Transmitter

2. Fox Thermal FT3 Mass Flow Meter & Temperature


Transmitter

Field selectable units SCFM, NM3H,


Kg/Hr and more
Turndown range typically 100:1
Measures process gas and temperature
4 to 20 mA outputs for flow and
temperature; pulse output for flow
316 stainless steel sensor; Hastelloy C276
optional
USB connection standard (free FT3 View
Software); Optional HART and RS485
Modbus
Optional display, LCD 2 line, 16 character, backlit, Infrared (IR) button
CAL-V in pipe calibration validation

Zero CAL-CHECK calibration validation feature


Power input 24 VDC or optional 85 to 264 VAC in local or remote enclosures
FM and FMc approvals
ATEX and IECEx approvals, Zone 1 and 2
Class I, Div 1, Groups B,C,D
Class I, Div 2, Groups A,B,C,D
Class II & III, Div 1, Groups E,F,G
Indoor/outdoor NEMA 4X and CE approved

3. Rosemount 2051CFC Compact Orifice Flow Meter

Spesifikasi :
1/2 to 12" pipe size
Available up to ANSI 600# pressure rating
Follows industry standard utilizing ASME and ISO corner tap design
Installation between existing raised-faced flanges
Self centering ring ensure optimal accuracy while improving installation
Up to 2.00% volumetric flow accuracy at 5:1 turndown
2-year stability
Aluminum and SST housings available
Transmitter output: 4-20mA HART, FOUNDATION fieldbus, Profibus PA
Protocol, Low Power HART
Conventional bid spec compliance optional reference accuracy and
stability improvements
Ease-of-Use features, enhanced EDDL screens, optional external zero and
span buttons

S-ar putea să vă placă și