Rev. no :
Page 1 of 35
Uncontrolled Copy
________________________________________________________________________
Content
I.
Objectives........................................................................................................................4
II.
Work Preparation............................................................................................................4
III.
III.1.
Modules............................................................................................................................6
Commissioning................................................................................................................9
IV.1.
Visual Check....................................................................................................................9
IV.2.
IV.4.
Definition of Rack..........................................................................................................17
IV.5.
Creation of Module........................................................................................................19
IV.5.1. COSA..............................................................................................................................20
IV.5.2. CU...................................................................................................................................21
IV.5.3. DULNA............................................................................................................................22
IV.5.4. DUVSWR.......................................................................................................................23
IV.5.5. FAN.................................................................................................................................24
IV.6.
IV.7.
Creation of BPORT.......................................................................................................25
IV.8.
Creation of LAPDLE.....................................................................................................26
IV.9.
Setting BTSM.................................................................................................................28
Integration......................................................................................................................31
VI.
Rev. no :
Page 2 of 35
Uncontrolled Copy
________________________________________________________________________
VII.
Appendix........................................................................................................................33
I.
Objectives
Rev. no :
Page 3 of 35
Uncontrolled Copy
________________________________________________________________________
This document is intended to be used as a reference to guide the BS240/ 240XL
commissioning and BTS function testing. It contains all description of procedure
commissioning the BTS system.
Dokumen ini ditujukan untuk membuat suatu petunjuk acuan dalam komisioning BS240/
240XL dan test fungsinya. Dokumen ini mencakup seluruh prosedur komisioning BTS.
II.
Work Preparation
Persiapan Pekerjaan
Before starting the commissioning works, these document and information below must
be available:
a. Work Instruction Document (see app.2.1)
b. OHSE document (see app 2.2)
c. DBCR or database change request (see app 2.3)
d. Information of PCML and all radio system number that will be used
d. BSS Asplan, which is left inside rack by former installation team (see app.2.4)
III.
Rev. no :
Page 4 of 35
Uncontrolled Copy
________________________________________________________________________
III.1. Modules
Modul
The categories for the main BTS plus components are:
Core boards (COBA/COSA)
Carrier Units (CU)
Combining equipment (DUAMCO, FICOM, DIAMCO)
Up to 8 PCMB lines can be connected to the two core boards. The main communication
between the modules runs via a bi-directional serial link between the carrier units and
the core boards (CC-Link). The serial link is also used for base band frequency hopping.
Alarms of the CU boards are transmitted via CC-Link. All non-CU boards (e.g.
DUAMCO) report their alarms to COBA via the CAN Bus.
Company : PT. Siemens Indonesia
COM CS TKS
Prepare : Donny Tambunan
Rev. no :
Page 5 of 35
Uncontrolled Copy
________________________________________________________________________
Carrier Unit
CU
The carrier units CU contains all analogue and digital signal processing units (including a
RF power stage) to provide a single GSM/ EDGE carrier (with 8 time slots). The carrier
unit interfaces to the combining equipment via semi-rigid cabling and to the Core Module
via CC-Link.
Rev. no :
Page 6 of 35
Uncontrolled Copy
________________________________________________________________________
Rev. no :
Page 7 of 35
Uncontrolled Copy
________________________________________________________________________
DUAMCO/FDUAMCO
The DUAMCO modules contain duplex filters in order to combine transmit and receive
path to one antenna connector. The receive path consist LNA (low noise amplifier) and
power splitter. The DUAMCO amplifier has two different operation modes which can be
selected by e.g. DIP switches. In the following, Mode 1 is called AMCO mode where no
TMA is used and the second mode is called MUCO mode where TMA is used.
Fig. 3 FDUAMCO
IV.
Commissioning
For commissioning BS24x/ BS4x, there are some steps/ procedures that needed to do.
Company : PT. Siemens Indonesia
COM CS TKS
Prepare : Donny Tambunan
Rev. no :
Page 8 of 35
Uncontrolled Copy
________________________________________________________________________
The main steps are:
Rev. no :
Page 9 of 35
Uncontrolled Copy
________________________________________________________________________
COBA Setting
Rev. no :
Page 10 of 35
Uncontrolled Copy
________________________________________________________________________
Rev. no :
Page 11 of 35
Uncontrolled Copy
________________________________________________________________________
Rev. no :
Page 12 of 35
Uncontrolled Copy
________________________________________________________________________
Rev. no :
Page 13 of 35
Uncontrolled Copy
________________________________________________________________________
Switch Setting COSA
IV.2.2. Combiner
The DIP switches on the front side of DUAMCO determine whether the DUAMCO run in
AMCO or in MUCO mode.
IV.2.3. ACT
On the ACT, the rack address must be set. For the base rack and the extension rack 0,
the racks address setting done by factory. Thus only for extension rack 1, setting on site
is required.
Rev. no :
Page 14 of 35
Uncontrolled Copy
________________________________________________________________________
Download the BTS plus software from the LMT hard disk to the COBA FEPROM.
Rev. no :
Page 15 of 35
Uncontrolled Copy
________________________________________________________________________
After the download is completed, activate the BTSM software then the COBA and CU
Ram are loaded and the BTSM reaches Phase 2. The LMT session is closed and new
logon is required.
Rev. no :
Page 16 of 35
Uncontrolled Copy
________________________________________________________________________
Activation of BTSM
For the base rack (RACK: 0) the command SET RACK has to be used, and for
extension rack (RACK: 1&2) we used command CREATE RACK.
Rev. no :
Page 17 of 35
Uncontrolled Copy
________________________________________________________________________
Rev. no :
Page 18 of 35
Uncontrolled Copy
________________________________________________________________________
Creation of Rack
IV.5.1. COSA
Company : PT. Siemens Indonesia
COM CS TKS
Prepare : Donny Tambunan
Rev. no :
Page 19 of 35
Uncontrolled Copy
________________________________________________________________________
COSA must be created to use more than two PCM lines or more than 8CUs, also for
using cross connect function. For BS-240/ 240 II/ 240XL/ 240XL II, there can be 8 PCM
lines connected. PCM 1 and 2 supplied by COBA, and PCM 3 to 8 supplied by COSA.
The COSA can only be installed in Base Rack (RACK: 0).
Creation of COSA
CREATE COSA:NAME=RACK0/COSA:(no: 0 or 1)
COSA 0
COSA 1
IV.5.2. CU
Rev. no :
Page 20 of 35
Uncontrolled Copy
________________________________________________________________________
The base rack and the extension racks can be equipped with 8 CUs each (12 CUs in
BS-240XL/ 240XL II). For more than 8 CUs perbs-240 / 240 II/ 240XL/ 240XL II, the
module COSA must be created.
Creation of CU
IV.5.3. DULNA
DULNA supplies the Rx path of DUAMCO/ FDUAMCO. There are two managed objects
per module. They must be handled separately. Each CU has a normal path Rx input
Company : PT. Siemens Indonesia
COM CS TKS
Prepare : Donny Tambunan
Rev. no :
Page 21 of 35
Uncontrolled Copy
________________________________________________________________________
and a diversity path Rx input and the wiring data indicate which of them is physically
connected to the DUAMCO LNA.
Creation of DULNA
CREATE DULNA:NAME=RACK:(no)/DULNA:(no), CELLNO=(no), COMBMD=(combiner
mode), LNAPRED=(pred type), WDLNA=(no of CU normal or diversity mode).
IV.5.4.
DUVSWR
DUVSWR supplies the Tx path of DUAMCO/ FDUAMCO. There are two managed
objects per module. They must be handled separately.
Rev. no :
Page 22 of 35
Uncontrolled Copy
________________________________________________________________________
Creation of DUVSWR
CREATE DUVSWR=Rack:(no)/DUVSWR:(no), CELLNO=(no),COMBMD=(combiner
mode), WDDUVSWR=(no 0f CU).
IV.5.5. FAN
The rack can be equipped with 6 fans (8 fans in BS-240XL/ 240XL II). During the
creation of each fan, the alarm for defective fan is generated automatically.
Rev. no :
Page 23 of 35
Uncontrolled Copy
________________________________________________________________________
Creation of FAN
Rev. no :
Page 24 of 35
Uncontrolled Copy
________________________________________________________________________
layer1RemoteAlarmType
line Configuration
line Impedance (default, no need to configure)
Creation of BPORT
Rev. no :
Page 25 of 35
Uncontrolled Copy
________________________________________________________________________
Creation of BPORT
Rev. no :
Page 26 of 35
Uncontrolled Copy
________________________________________________________________________
Creation of LAPDLE
Rev. no :
Page 27 of 35
Uncontrolled Copy
________________________________________________________________________
The BTSM setting includes the TEI (Terminal Endpoint Identifier). The TEI together with
the SALUNAME forms the unique BTSM addresses, which must be set in accordance
with the BSC data base.
Rev. no :
Page 28 of 35
Uncontrolled Copy
________________________________________________________________________
After switch to PH 3 the LMT session is closed and a new logon is required.
The LED on the module will show:
The LED on COBA
The LED on CU
Rev. no :
Page 29 of 35
Uncontrolled Copy
________________________________________________________________________
High active: alarm message starts if the pins are opened.
Low active: alarm message starts if the pins are closed by short circuit.
Alarm severity level can be chosen: critical, major, minor.
IV.12.Remote Inventory
Inventory data are used for the functional and physical identification of HW/FW modules
in the SBS. The modules, shelf, etc are equipped with labels. On these labels the
product identification data is stored. The main point is to combined the NOB and OB.
Hardware Check
We need to check all module state to make sure it works properly. This is can be
done with get state the module, this is will be confirmed by the state event
report:
Administrative State = UNLOCKED
Operational State = ENABLED
For all successfully created objects
V.
Integration
There are some steps in Integration BTS:
-
Get entry permit letter from Customer to each site that passed for
transmission connection
Create PCMB on BSC
Cross-connect the link from BSC to BTS
Give and cross check data for integration to OMC-B, e.g. BSC to connect,
PCML (PCM circuit number), PCMB, TEI, TS for LAPDLE (signaling)
Request for download database to Siemens Regional
Rev. no :
Page 30 of 35
Uncontrolled Copy
________________________________________________________________________
VI.
It is mandatory to do some test after the site on air, to make sure the site can be used to
make a call and the hardware working properly (e.g. power output CU in spec margin).
The tests are:
Power Measurement
In power measurement, it has two kind measurements. Measuring power after
CU (before DUAMCO) and after DUAMCO. The power measurement result is
reported in CU & DUAMCO Power Measurement Form(See app. 6.1 )
Power Measurement after CU (before Combiner)
Power Output from ECU GSM > 48.3 dbm
Power Output from ECU DCS > 47.3 dbm
Power loses in DUAMCO
Test Call
In test call, we need tools named TEMS (product by Ericsson) and GPS. We also
need some data: DBCR + coverage plot, map site.
Perform test call in each sector and around the site to check. Test call result is
reported in Test Call Report Form (see app 6.2):
All timeslots are created and can be used
Make sure the all time slot are created can be done by dedicated call with
channel verification in TEMS
Rev. no :
Page 31 of 35
Uncontrolled Copy
________________________________________________________________________
Rev. no :
Page 32 of 35
Uncontrolled Copy
________________________________________________________________________
Commissioning
Finished
Identify any
changes
Commissioner
Commissioner
Commissioner
Red marking of
any changes in
BSS asplan doc
Taking Pictures
Correction
Final Red
Correction File &
Photo (Draft)
Siemens Spv
Red Correction
Check
N
Approved?
Y
Red Correcrtion
File (Approved) +
Photo
Commissioner
Submit the approved
final red correction to
Siemens BAST admin
Rev. no :
Page 33 of 35
Uncontrolled Copy
________________________________________________________________________
Red correction is performed by providing a Red Mark in former BSS asplan document
for any change in equipment layout, equipment type, dimension etc. Also some
photograph is necessary to be taken. List of picture to be taken can be seen in App 7.1
and sample of each picture can be seen in App. 7.2
Siemens Supervisor is responsible to decide if a red correction file has been done
according to requirement or not.
After a red correction approved by Siemens Supervisor then Commissioner must submit
the final red correction document (together with complete BAST doc) to BAST Admin in
Siemens regional office.
7.3 Acceptance Test Procedure
Acceptance Test Procedure is performed according instruction explained inside TTP
BSS 240 and TTR BS 240 (see App. 7.3). This activity must be performed under
Supervision from Siemens Supervisor.
Installation Supervisor will decide if every item of installation result is accepted or not
7.4 Incident and Accident Report
If there was any Accident during installation work, then it must be reported by using
Accident & Incident Report form (see App. 7.4)
It also necessary to report that tower work has been completed safely by using Tower
Work Completin Statement (see App. 7.5)
7.5 BAST Documentation
Last activity from whole Installation is completion of BAST Documentation.
No
Document Name
Work Instruction
Job Safety Analysis
Work Permit
Hazard Identification Record (incidental)
3
1. Accident Record (if any)
4. ATP Document
ENVA Test Result
CU & DUAMCO Power Measurement
Test Call Report Form
Red Correction Document
Red Correction Photo (softcopy)
6. Work Completion Time Report (WCTR)
7. Timesheet
5. ATP Hand Over
Tab. 6.1 List of complete BAST document
Inst SPV
RM
Rev. no :
Page 34 of 35
Uncontrolled Copy
________________________________________________________________________
Sample of Work Completion Time Report (WCTR)can be seen in App. 7.6, sample of
Timesheet can be seen in App. 7.7, and sample of ATP hand over can be seen in App.
7.8
The complete BAST document will be submitted to Siemens Regional Office for further
commercial administration