Documente Cultură
s=3*dia=1.2 m
dia=0.4 m
B=3.6 m
Apg=3.6*3.6=12.96 m2
Rpg=N*Cu=9*50=450 KN/m2
Asg=4*3.6=14.4 m
Rfg=(5*23)+(5*15)+(10*50)=690
so Qug=15768 KN
so safe load = minimum of Qug and Qu which is 7389.04 divided by factor of safety i.e 2.5
so safe load = 7389.04/2.5 = 2955.616 > 2910 KN hence Safe.
action of column loading) as show in the below fig. Is there any way to reduce the area
requirement and the depth of pile cap?
1570 mm
450
80 mm
P
i
L
e
P
i
L
e
400 mm
2) Now if I provide beam over all the piles and apply the column load on the beam, the depth
required is coming out to be 900 mm but then the truss action of the pile cap i.e. drawn at 450
from the axis line of column is failing. Is it right to provide beam over piles for load distribution
of column. What should I do in such condition?
3) Can I arrange the column in the following way (as shown in below
fig), ofcource considering the minimum spacing required between
the Piles (s=3dia).In this way I think the truss action of the column
load distribution will be satisfied but I m afraid that this will
concentrate the column load on the middle 4 piles only and the
load carried by each piles will not be equal (unwanted condition).
Please suggest any way out.
If there is any other idea, the it is fully welcome.
P
i
L
e
400 mm