Variable Refrigerant Flow Air Conditioning Systems

ISO 9001

ISO 14001

R410A

Printed in Japan (H) HR-E568T Jun. 2008

Releasing a next-generation variable


refrigerant flow air conditioning
systems designed for buildings that
saves energy, construction time,
and installation space!!

Variable Refrigerant Flow Air Conditioning Systems

R410A
Energy
Energy Saving
Saving
Thanks to Hitachis unique energy-saving technology
such as the high-efficiency DC inverter compressor,
industry-leading COP has been achieved.

All buildings require a good air conditioning system that


matches the width, structure, functions and so forth.
We specialize in creating the optimal air conditioning system to
suit the requirements of each building. We have continuously

Easy
Easy Installation
Installation
All-in-one compact design for all models of outdoor
units. Simplifies the installation and increases the
flexibility of location.

developed sophisticated energy-saving air conditioning systems


that reduce CO2 emissions and consider the global
environment. Hitachi is proud to release its latest variable
refrigerant flow air conditioning systems, the SET-FREE FSN

Wide Product Range


6 types and 19 models of outdoor units
7 types and 39 models of indoor units

series featuring high energy-saving, easy installation and


compact size for next-generation buildings.

Comfort
Comfort
Fine temperature setting and noise reduction
technology for comfortable air conditioning.

Reliability
Reliability
Hitachis long scroll compressor
experience ensures greater reliability.

Adopts latest technologies


Newly-developed, Highly-efficient
2-blade-Inverness Fan
High-efficiency Fan Module

High-efficiency, Constant-speed Compressor


Large-capacity DC Fan Motor

Vector-control DC Inverter

Newly-developed,
Energy-saving Heat Exchanger

High-efficiency DC Inverter Compressor

Supercooling Circuit

Wide Product Range


Space, structure, and necessary functions. In line with the evolution in building design,
the requirements for air conditioning have also diversified.
The Hitachi SET-FREE FSN series offers 6 types of all-in-one outdoor units and
7 types (39 models) of indoor units. By combining units from a wide selection of models, you
can create a custom air conditioning environment to satisfy your specific building conditions.

Indoor Units
Capacity Range [HP]

1.0

1.5

2.0

2.5

3.0

4.0

5.0

RCI1.0FSN2

RCI1.5FSN2

RCI2.0FSN2

RCI2.5FSN2

RCI3.0FSN2

RCI4.0FSN2

RCI5.0FSN2

RCD1.0FSN2

RCD1.5FSN2

RCD2.0FSN2

RCD2.5FSN2

RCD3.0FSN2

RCD4.0FSN2

RCD5.0FSN2

RPI1.0FSN2

RPI1.5FSN2

RPI2.0FSN2

RPI2.5FSN2

RPI3.0FSN2

RPI4.0FSN2

RPI5.0FSN2

RPC2.0FSN2

RPC2.5FSN2

RPC3.0FSN2

RPC4.0FSN2

RPC5.0FSN2

0.8

8.0

10.0

RPI8FSN

RPI10FSN

4-Way Cassette

RCI-FSN2

Outdoor Units
Capacity Range [HP]

Outdoor units selectable in increments of 2HP.


5

10

12

14

16

18

20

22

2-Way Cassette

RCD-FSN2

RAS5FSN

RPI0.8FSN2
In-the-ceiling

RPI-FSN(2)

RAS8FSN1

RAS10FSN1

RAS12FSN1

4
Ceiling

RPC-FSN2

RAS14FSN1

RAS16FSN1

RPKRPKRPKRPKRPKRPK1.0FSNSM2 1.5FSNSM2 2.0FSNSM2 2.5FSNSM2 3.0FSNSM2 4.0FSNSM2


Wall

RPK-FSNSM2

RAS18FSN1

RAS20FSN1

RAS22FSN1

RPF1.0FSN2E

RPF1.5FSN2E

RPFI1.0FSN2E

RPFI1.5FSN2E

Floor

RPF-FSN2E
Capacity Range [HP]

24

RAS24FSN1

26

RAS26FSN1

28

RAS28FSN1

30

RAS30FSN1

32

34

36

38

40

42

Floor Concealed

RAS32FSN1

RPFI-FSN2E

System Equipment
Capacity Range [m3/h]

RAS34FSN

RAS36FSN

RAS38FSN

RAS40FSN

RAS42FSN
Total Heat Exchanger

KPI

250

500

KPI2521

KPI5021

800
KPI8021

1,000
KPI10021

Energy-saving and Comfort


Hitachis sophisticated energy-saving technology delivers outstanding effects.
The various cooling circuit technologies incorporated and new R410A DC inverter compressor
equipped achieve an industry-leading level of efficiency and energy-saving performance.

Supercooling Circuit
Performance improved by highefficiency plate type heat exchanger.

Top Class COP

Effect of Subcooler

COP increased by 40% over conventional models

Refrigerating ability
increased by
supercooling circuit

Comparison of average cooling/heating COP with


Hitachi R407C series (previous model series).

Cooling Operation

Heating Operation

(%)

(%)

158% 149%
144% 140%

157%
150

COP

COP

150

100

160%
140%

141%

Optimization of Heat Exchanger


Heating Operation:
The drop in evaporating temperature is prevented
by arranging 1 liquid path and 2 gas paths.
Frost build-up is prevented by the sub-cooler
located in the lower part.

100

Conceptual Diagram
Cooling Operation

Heating Operation

Cooling Operation:
Cooling ability is enhanced by the sub-cooler.
8HP

10HP

16HP

20HP

8HP

10HP

16HP

20HP

Comparison when COP of R407C series is 100%.


For a single outdoor unit
The cooling and heating performances shown are the values when combined with our specified indoor units.

Subcooler

Subcooler

Use of Supercooling Circuit


By using a supercooling circuit for the
refrigeration cycle and optimizing the piping
system, the performance is greatly improved.

NEW High-capacity Inverter Compressor.


Reversing Valve

Comfortable, energy-efficient operation


thanks to DC inverter motor and new drive
mechanism. Weight is 50% less than
conventional compressors, thus reducing
the weight of outdoor units.

Oil Separator

Reduced piping pressure


loss in the unit
HP

R410A
New Scroll Tooth Form

Compressor

s
Accumulator

Supercooling circuit adopted


Piping pressure loss decreased
by subcooling in liquid pipe.

Outdoor Expansion Valve

s
Subcooler
Heat Exchanger for Supercooling

Hitachis scroll, with more than


20 years of history, is now even
better.

Heat loss and mechanical loss


largely reduced during
refrigerant compression,
thus reliability greatly improved.

DC inverter motor
High-efficiency operation for
low- to high-speed airconditioning loads.

Receiver

2-gas, 1-liquid pass arrangement


Subcooler in front

Outdoor Heat Exchanger

Expansion Valve
for Supercooling

Optimized heat exchanger

Patented

HP

s
Optimizing expansion
valve control

New drive mechanism


(oil control mechanism, etc.)

Energy-saving and Comfort

Capacity Control by 1 Hz, The Only One in The Industry


Performance is greatly improved by the high-By vector-controlling the high
efficiency DC inverter compressor and 100% load compressor, energy-saving
operation without loss is achieved (depending on building load).

16HP

Inverter
Compressor

18

Cooling Load

Min.

Inverter
Compressor

No.2 Compressor

Inverter
Compressor

-5C

70Steps

-20

Cooling Load

Inverter
Compressor

No.4
Compressor
No.3 Compressor

No.2 Compressor

Min.

Min.

Cooling Load

*No.2 ~ No.5 compressor load 100%.

Inverter Controled
Non-inverter Controled

Preset Temperature

Precise

Time

Noise is suppressed by decreasing the number of


blades from 4 to 2.
Although the number of blades is decreased, each
blade is longer, thus the air quantity is increased by
25%.

20

30

40

50

Excessive power
consumption exceeding the
power setting is curtailed.

Maximum efficiency
secured in a range below
NEW Wave function
the power setting
Daytime

Wave mode equipped to turn


demand control ON and OFF
alternately at intervals of
about 20 min. or 10 min.
While power is saved without
fail, temperature changes
are also minimized to
maintain a comfortable room
temperature.

Without Demand Control

Night

Selectable from 100%,


80%, 70% and 60% of
rated power
consumption for
cooling purposes

10C

Long Duct Bell-mouth

With Demand Control

Average Power Consumption

Power Setting

10

10

10

10

10

10

10

10 (Min.)

Power Setting

10

10

10

10

10

10

10

10 (Min.)

NEW Smart Balance Control

Room Temp.

2-Blade Inverness Fan

Effects of
Demand Control

Average Power Consumption

The performance is the same regardless of the


length of the refrigerant pipe.

2-Blade Fan Technology


Industry-first, 2-Blade Inverness Fan

10

Operation Time

NEW Wave Mode


(C)

Power Setting

Morning

Power Consumption

By properly controlling the refrigerant


quantity by an electronic expansion valve,
the temperature can be finely set.

-10

Self-demand Control

A newly developed self-demand function


has largely improved energy-saving effects.
Since the current is self-detected and
demand control performed automatically,
no signal wiring work is required.
Conventional demand control using demand
signals is also available, and you can select
various operations as required.

Precise Temperature Setting


Temperature at which indoor unit
blows warm air

43C

Self-demand Control

No.5
Compressor

7
Max

Cooling

30Hz~100Hz

100

70Steps

12
Max

15C

22HP
(%)

30Hz~100Hz

Compressor Control
Capacity

Compressor Control
Capacity

70Steps

Heating
-20C

Power Consumption

(%)
100

30Hz~100Hz

Compressor Control
Capacity

100

SET-FREE FSN can handle a wide range of


outside air conditions, thus extending the
flexibility of installation space and climatic
environment.

Power Consumption

8HP
(%)

Wide Working Range

Quickly senses air temperature difference to


demonstrate proper performance.
Energy-saving operation without loss realized.

Set Temp.

20C

Room Temp.

15C

Set Temp.

20C

In case of the difference


between room temperature
and set temperature is

Floor near
the outdoor unit

5C (Small).

Optimal
Performance!

Optimal
Performance!

High Static Pressure, Long Duct Bell-mouth


Fan power consumption reduced by combining with
inverness fan.

Room Temp.

10C

Floor far from


the outdoor unit

Optimal
Performance!

Set Temp.

20C

In case of the difference


between room temperature
and set temperature is

10C (Large).
Optimal
Performance!

Flexibility of Installation
Industry-unique all-in-one compact design for all models,
simplified installation and increased flexibility of location!

More Flexible Refrigerant Piping Works


Improved flexibility of design by increasing the pipe length
to 150 m max. (equivalent length of 175 m) in FSN series.

Compact Design
Outside dimensions of the series are reduced, 10% less Installation Space,
and weight reduced by 19% on average compared with conventional series.
Conventional Model (16HP)

RAS-16FSN1

Reduced by

Conventional Model (42HP*)

37%

Max. pipe length: 150 m*1

Between first branch and indoor unit: 40m or less

Height difference between highest and


lowest indoor units: 15m or less

Reduced by

RAS-42FSN

31%

Height difference between outdoor and indoor units: 50m*2

3
2

*1) For 100m or more, the pipe diameter will be one size larger.
case the outdoor unit is installed at a higher level than indoor units.
*2) IfInthe
outdoor unit is installed lower than indoor units, the maximum
RAS-16FSG

RAS-16FSG

In Case of RAS-16FSN1

RAS-16FSG

height difference is 40m.

RAS-10FSG

In Case of RAS-42FSN

Installation Space : Reduced by 37%

Combined Unit to Improve Capacity

Installation Space : Reduced by 31%

Weight : Reduced by 31%

* One example of unit combination when a capacity


of about 42HP is required in the conventional model

Weight : Reduced by 22%

Easier Piping Work


By employing the integral-type unit for all product series, piping and wiring are
easier, thus reducing construction time and raising maintenance reliability.

NOTES:
( ): Max. number of min. capacity
indoor units connectable.

HITACHI
SET-FREE FSN Series

Typical Construction Example of a Standard System

Indoor unit connected capacity range :


* 50-130%
of outdoor unit capacity.
Secure air permeability in the event of
* refrigerant
leakage.

2 outdoor Units
Installed

Power Source,
Grounding Wire
Transmission
Line

Power Source,
Grounding Wire,
Transmission Line,
Connecting Wire

Power Source,
Grounding Wire

Outdoor
Connecting Pipes
(Gas, Liquid)

Transmission
Line

Outdoor
Connecting Kits
(Gas, Liquid)

Gas Pipe
Liquid Pipe

Conventional Model
Outdoor Unit
Capacity

Min. Capacity of
Indoor Units Connectable

Max. Number of
Indoor Units Connectable

Outdoor Unit
Capacity

0.8 HP

0.8 HP

8 (8)

8 (8)

26 HP

0.8 HP

8 HP

0.8 HP

0.8 HP

13 (13)

13 (13)

28 HP

0.8 HP

10 HP

0.8 HP

0.8 HP

16 (16)

16 (16)

30 HP

Liquid Pipe

16 (16)

32 HP

0.8 HP

32 (12)

20 (20)

34 HP

0.8 HP

32 (12)

20 (20)

36 HP

0.8 HP

32 (12)

20 (20)

38 HP

0.8 HP

32 (12)

20 (20)

40 HP

0.8 HP

32 (12)

20 (20)

42 HP

0.8 HP

32 (12)

16 HP

1.0 HP

20 HP
24 HP

0.8 HP

16 (16)

0.8 HP

18 HP
1.0 HP

0.8 HP

16 (16)

0.8 HP

22 HP
1.0 HP

0.8 HP

27 (12)

27 (12)

Pipe Downsizing

5HP
8HP
10HP
12HP
14HP
16HP
18HP
Front

Downwards

20HP
22HP

Refrigerant-saving

24HP
26HP

Additionally-enclosed refrigerant is largely reduced by


refrigerant-saving technology.
Refrigerant Saving
Example of a 10HP System : Outdoor Unit: 10HP
Indoor Unit: 2.5 HP x 4 (units)
Main Pipe: 70 m
Branch Pipe: 30 m

Conventional Model

SET-FREE FSN

9.53

0.065 x 30 x 4=7.8kg

0.070 x (70 + 30 x 4)=13.3kg

12.7

0,120 x 70=8.4kg

Pipe Size

Total

16.2kg(100%)

28HP
30HP
32HP
34HP

13.3kg (82%)

Additional Refrigerant Reduced by

18%

32 (12)

0.8 HP

SET-FREE FSN

Liquid

Rear

31 (12)
32 (12)

0.8 HP

R407C Model

In an outdoor unit, piping connections are easily


conducted from any of three directions:
" front, rear or downwards ".

0.8 HP

29 (12)

14 HP

Supercooling
Circuit Effect

: Areas where no installation is required in the FSN series

Refrigerant Piping Connections

1.0 HP

Max. Number of
Indoor Units Connectable

12 HP

By downsizing the piping compared with the R407C unit,


installation is easier and piping material costs are reduced.

Gas Pipe

SET-FREE FSN

Min. Capacity of
Indoor Units Connectable

5 HP

36HP
38HP
40HP
42HP

9.53
9.53 -12.7
9.53 -12.7
12.7 -15.88
12.7 -15.88
12.7 -15.88
15.88 -19.05
15.88 -19.05
15.88 -19.05
15.88 -19.05
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2

(Pipe length

100m)

Gas

15.88
19.05 -22.2
22.2 -25.4
25.4 -28.6
25.4 -28.6
28.6 -31.75
28.6 -31.75
28.6 -31.75
28.6 -31.75
28.6 -31.75
31.75 -34.92
31.75 -34.92
31.75 -34.92
31.75 -34.92
31.75 -34.92
34.9 -41.3
34.9 -41.3
34.9 -41.3
34.9 -41.3

Comparison of Cooling Capacity


(In Compressor Discharge Volume)

As shown in the right table, the


minimum capacity and maximum
number of indoor units to be
connected are increased to
match the indoor load.

[%]

Difference in
Refrigerant
Properties

190%

100%
100

RAS-FSG

RAS-FSN
*Our Test Result

Pipes can be downsized because refrigerant


pressure loss is greatly reduced, and
discharge volume is small for the same
capacity compared with R407C.

10

General Data
Outdoor Units
RAS-5FSN

Model

RAS-8FSN1

Power Supply
Nominal Cooling Capacity *1)

Nominal Cooling Capacity *2)

Nominal Heating Capacity

RAS-12FSN1

RAS-14FSN1

RAS-16FSN1

RAS-18FSN1

RAS-20FSN1

RAS-24FSN1

RAS-26FSN1

RAS-28FSN1

kW

14.5

23.3

29.1

34.9

40.7

46.5

52.3

58.1

64.0

69.8

75.6

81.4

12,500

20,000

25,000

30,000

35,000

40,000

45,000

50,000

55,000

60,000

65,000

70,000

Btu/h

49,700

79,400

99,300

119,100

138,900

158,800

178,600

198,500

218,300

238,100

258,000

277,800

kW

14.0

22.4

28.0

33.5

40.0

45.0

50.4

56.0

63.0

69.0

73.0

80.0

kcal/h

12,000

19,300

24,100

28,800

34,400

38,700

43,300

48,100

54,100

59,300

62,700

68,800

Btu/h

47,800

76,400

95,500

114,500

136,800

153,400

172,000

191,200

215,100

235,300

249,300

273,500

kW

16.0

25.0

31.5

37.5

45.0

50.0

56.0

63.0

71.0

77.5

82.5

90.0

kcal/h

13,800

21,500

27,100

32,200

38,700

43,000

48,100

54,100

61,000

66,600

70,900

77,400

Btu/h

54,600

85,300

107,500

128,000

153,900

170,400

191,200

215,100

242,500

264,200

281,800

307,700

Natural Gray

Sound Pressure Level

Natural Gray

Maximum

(Overall A Scale)

RAS-22FSN1

AC 3 , 380-415V / 50Hz, 220V / 60Hz, 380V / 60Hz

kcal/h

Cabinet Color

Maximum

(Night-Shift)

dB

52 (47)

56 (51)

58 (53)

60 (55)

61 (56)

62 (57)

62 (57)

62 (57)

63 (58)

63 (58)

63 (58)

64 (59)

Dimensions H x W x D

mm

1,645 x 630 x 750

1,745 x 950 x 750

1,745 x 950 x 750

1,745 x 950 x 750

1,745 x 1,210 x 750

1,745 x 1,210 x 750

1,745 x 1,910 x 750

1,745 x 1,910 x 750

1,745 x 1,910 x 750

1,745 x 2,430 x 750

1,745 x 2,430 x 750

1,745 x 2,430 x 750

kg

160

215

225

225

335

335

460

460

535

675

675

720

23.0

24.0

25.0

1.4 (4) + 4.4 (2) x 4

1.8 (4) + 4.4 (2) x 4

1.4 (4) + 4.4 (2) x 5

Net Weight
Refrigerant (Flow Control)
Refrigerant Charge

R410A (Micro-Computer Control Expansion Valve)


kg

5.4

7.0

R410A (Micro-Computer Control Expansion Valve)

8.5

9.0

13.0

13.0

19.0

19.0

Hermetic (Scroll)

Compressor
Motor Output

kW

3.0 (4)

4.8 (4)

6.0 (4)

7.2 (4)

4.8 (4) + 4.4 (2)

6.0 (4) + 4.4 (2)

6.0 (4) + 5.6 (2)

7.2 (4) + 5.6 (2)

Air Flow Rate m3/min.

1.8 (4) + 4.4 (2) x 3

Multi-Pass Cross-Finned Tube

Propeller Fan

Condenser Fan

19.0
Hermetic (Scroll)

Multi-Pass Cross-Finned Tube

Heat Exchanger

Propeller Fan

87

138

172

185

210

210

344

344

344

382

382

382

(cfm)

(3,072)

(4,874)

(6,074)

(6,533)

(7,416)

(7,416)

(12,148)

(12,148)

(12,148)

(13,490)

(13,490)

(13,490)

kW

0.16 (8)

0.38 (8)

0.38 (8)

0.38 (8)

0.38 (8)

0.38 (8)

0.38 (8) + 0.275 (6)

0.38 (4) + 0.275 (6)

0.38 (4) + 0.275 (6)

0.38 (8) + 0.275 (6)

0.38 (8) + 0.275 (6)

0.38 (8) + 0.275 (6)

9.53

9.53-12.7

9.53-12.7

12.7-15.88

12.7-15.88

12.7-15.88

15.88-19.05

15.88-19.05

15.88-19.05

15.88-19.05

19.05-22.2

19.05-22.2

15.88

19.05-22.2

22.2-25.4

25.4-28.6

25.4-28.6

28.6-31.75

28.6-31.75

28.6-31.75

28.6-31.75

28.6-31.75

31.75-34.92

31.75-34.92

Min. Capacity of Indoor Units Connectable

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

Max. Number of Indoor Units Connectable

13

16

16

20

20

20

20

20

27

29

31

0.87

1.44

1.44

1.44

1.81

1.81

2.82

2.82

2.82

3.57

3.57

3.57

RAS-30FSN1

RAS-32FSN1

RAS-34FSN

RAS-36FSN

RAS-38FSN

RAS-40FSN

RAS-42FSN

Motor Output

11

RAS-10FSN1

AC 3 , 380-415V / 50Hz, 220V / 60Hz, 380V / 60Hz

Refrigerant Piping

Liquid

mm

Gas

Approximate Packing Measurement

m3

Model
Power Supply

AC 3 , 380-415V / 50Hz, 220V / 60Hz, 380V / 60Hz


kW

Nominal Cooling Capacity *1)

Nominal Cooling Capacity *2)

Nominal Heating Capacity

87.2

97.2

93.0

AC 3 , 380-415V / 50Hz, 220V / 60Hz, 380V / 60Hz

102.3

108.4

114.5

119.5

kcal/h

75,000

80,000

83,700

88,000

93,300

98,500

102,800

Btu/h

297,700

317,500

332,000

349,400

370,200

390,000

408,100

kW

85.0

90.0

96.0

101.0

107.0

113.0

118.0

kcal/h

73,100

77,400

82,600

86,900

92,100

97,200

101,600

Btu/h

290,000

307,700

327,900

344,900

365,400

385,900

403,000

kW

95.0

100.0

108.0

113.0

119.5

127.0

132.0
113,600

kcal/h

81,700

86,000

92,900

97,200

102,800

109,300

Btu/h

324,200

341,900

368,800

385,900

408,100

433,700

Cabinet Color
Sound Pressure Level

450,800

Natural Gray

Natural Gray

Maximum

Maximum

(Night-Shift)

dB

64 (59)

64 (59)

64 (59)

64 (59)

65 (60)

65 (60)

65 (60)

Dimensions H x W x D

mm

1,745 x 2,430 x 750

1,745 x 2,430 x 750

1,745 x 3,390 x 750

1,745 x 3,390 x 750

1,745 x 3,390 x 750

1,745 x 3,390 x 750

1,745 x 3,390 x 750

kg

720

720

920

920

920

970

970

Refrigerant (Flow Control)

R410A (Micro-Computer Control Expansion Valve)


kg

Refrigerant Charge

26.0

26.0

28.5

R410A (Micro-Computer Control Expansion Valve)


31.0

31.0

32.0

Motor Output

kW

1.4 (4) + 4.4 (2) x 5

1.4 (4) + 4.4 (2) x 5

Heat Exchanger

3.4 (4) + 5.6 (2) x 4

32.0
Hermetic (Scroll)

Hermetic (Scroll)

Compressor

4.9 (4) + 5.6 (2) x 4

6.6 (4) + 5.6 (2) x 4

2.5 (4) + 5.6 (2) x 5

Propeller Fan

Propeller Fan

Condenser Fan

4.1 (4) + 5.6 (2) x 5

Multi-Pass Cross-Finned Tube

Multi-Pass Cross-Finned Tube


382

382

554

554

554

554

554

(cfm)

(13,490)

(13,490)

(19,564)

(19,564)

(19,564)

(19,564)

(19,564)

kW

0.38 (8) + 0.275 (6)

0.38 (8) + 0.275 (6)

0.38 (8) + 0.275 (6) x 2

0.38 (8) + 0.275 (6) x 2

0.38 (8) + 0.275 (6) x 2

0.38 (8) + 0.275 (6) x 2

0.38 (8) + 0.275 (6) x 2

19.05-22.2

19.05-22.2

19.05-22.2

19.05-22.2

19.05-22.2

19.05-22.2

19.05-22.2

31.75-34.92

31.75-34.92

31.75-34.92

34.9-41.3

34.9-41.3

34.9-41.3

34.9-41.3

Min. Capacity of Indoor Units Connectable

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

0.8 HP

Max. Number of Indoor Units Connectable

32

32

32

32

32

32

32

3.57

3.57

4.99

4.99

4.99

4.99

4.99

Air Flow Rate m3/min.

Motor Output

Refrigerant Piping

Liquid
Gas

Approximate Packing Measurement

mm

m3

1. The above cooling and heating capacities show the capacities when the outdoor unit is operated with
the 100% rating of indoor units, and are based on the standard JIS B8616-1984.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
*1) 19.5C WB (67F WB)
*2) 19.0C WB (66.2F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20C DB (68F DB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
6C WB (43F WB)
Piping Length: 7.5 Meters

(Overall A Scale)

Net Weight

NOTES :

Piping Lift : 0 Meter

2. The sound pressure is based on following conditions.


1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode.
In case of heating mode, the sound pressure level increases by approximately 1~2dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.

12

Indoor Units

Indoor Units

4-Way Cassette Type

2-Way Cassette Type

Extremely Quiet Operation and


Elegant Design Matching Any Interior

Quiet operation and


Low Height Design for Any Ceiling
Low-profile design allows installation in a
small space inside of ceiling.

Newly Developed "Wide Air Flow Wing"


"Wide Air Flow Wing" is installed turning to the both sides of
the air outlet to allow the air distribution in every four corners
of the panel. Consequently, the sophisticated and
outstandingly comfortable air-conditioned environment
without temperature irregularity is provided.

A compact turbo fan simplifies the structure and


reduces the height to 298 mm, for easy installation.
Compact Turbo Fan

The Shutter function is newly adopted to conceal the air


outlet with the louvers when the operation is stopped.
The louvers cover the air outlet horizontally with providing
the neat appearance.
Air is distributed to all
four corners of panel.

IN Operation

OFF Operation

13

Downsizing and weight reduction simplify


handling for easier renewal.
Simplified Panel Wiring
The panel wiring connector is shifted to the air inlet grille
inside. No need to open the electrical box cover for panel
wiring work.

General Data
Model
Indoor Unit Power Supply
kW

Nominal Cooling
Capacity *1)

kcal/h
Btu/h
kW

Nominal Cooling
Capacity *2)

kcal/h
Btu/h
kW

Nominal Heating
Capacity

kcal/h
Btu/h

Sound Pressure Level


(Overall A Scale)

dB

Dimensions H x W x D

mm

Net Weight
Refrigerant

Motor

RCI-1.0FSN2

RCI-1.5FSN2

RCI-2.0FSN2
RCI-2.5FSN2
RCI-3.0FSN2
AC 1 , 220-240V / 50Hz, 220V / 60Hz

2.9
2,500
9,900

4.1
3,550
14,100

5.8
5,000
19,800

7.3
6,300
25,000

2.8
2,400
9,600
3.2
2,800
10,900

4.0
3,400
13,600
4.8
4,100
16,400

5.6
4,800
19,100
6.3
5,400
21,500

7.1
6,100
24,200
8.5
7,300
29,000

30-28-27

23

m3

Adaptable Panel Model


Color
Dimensions H x W x D

Net Weight
Approximate
Packing Measurement

mm

kg
m3

8.3
7,100
28,200

11.6
10,000
39,700

14.5
12,500
49,600

8.0
6,900
27,300
9.0
7,700
30,700

11.2
9,600
38,200
12.5
10,700
42,600

14.0
12,000
47,800
16.0
13,800
54,600

13/12/11
(459/424/388)

38-35-33

39-37-35

298 x 840 x 840

24
26
R410A / R407C / R22 (Nitrogen-Charged for Corrosion-Resistance)
15/13.5/12
(530/477/424)

16/14/12
(565/494/424)

20/17/15
(706/600/530)

21/18/15
(741/635/530)

29
32/28/24
(1,130/989/847)
124

Flare-Nut Connection (With Flare Nuts)


6.35 / 15.88
9.53 / 15.88
VP25

6.35 / 12.7

0.22

Model
Indoor Unit Power Supply
kW

Nominal Cooling
Capacity *1)

kcal/h

Nominal Cooling
Capacity *2)

kcal/h

Nominal Heating
Capacity

kcal/h

Btu/h
kW
Btu/h
kW

Even rooms with a high ceiling can be comfortably


air-conditioned by setting the speed-up tap with the
remote controll switch.

14
RCD-1.0FSN2

RCD-1.5FSN2

2.9
2,500
9,900

4.1
3,550
14,100

2.8
2,400
9,600

4.0
3,400
13,600

5.6
4,800
19,100

7.1
6,100
24,200

4.8
4,100
16,400

6.3
5,400
21,500

8.5
7,300
29,000

Btu/h

3.2
2,800
10,900

Sound Pressure Level


(Overall A Scale)

dB

34-32-30

Dimensions H x W x D

mm

Net Weight
Refrigerant
34/29/25
(1,201/1,024/883)

56

Condensate Drain
Approximate
Packing Measurement

RCI-5.0FSN2

32-30-28

W
mm

RCI-4.0FSN2

248 x 840 x 840

Connections
Liquid / Gas

Speed-up tap ensures comfortable air conditioning


even when installed as in the high ceiling.

The length of the 3HP type is shortened from 1,320 mm to


860 mm, the height is also shortened, and the volume is
reduced by about 50%.The reduced weight of 30 kg also
makes handling much easier.

General Data

kg

m3/min.
Air Flow Rate Hi/Me/Lo (cfm)

Top-class noise control thanks to compact turbo fan.


The three-dimensional twisted wings of the compact turbo fan
greatly reduce noise, and electromagnetic disturbance is
minimized by PWM (Pulse Width Modulation) control.

Industry-leading Low Sound Pressure Level


Highly-advanced low sound pressure level, 30 dB(A)
(1.0~2.0HP: at HIGH speed operation) is realized by
adopting the new DC fan motor and the vibration-proof
structure which protects the turbo fan from abnormal
sound. The low sound pressure level is 2 dB lower than the
conventinal units and further quiet operation is achieved.

298mm
Ceiling

35-32-30

Liquid / Gas

Approximate
Packing Measurement

P-N23WA
Silky White

Adaptable Panel Model


Color

37 x 950 x 950
6

Dimensions H x W x D

0.09

NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions. 1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. *3) In case of using R407C or R22, use the accessory adaptor and 19.05 piping.

11.6
10,000
39,700

14.5
12,500
49,600

8.0
6,900
27,300

11.2
9,600
38,200

14.0
12,000
47,800

9.0
7,700
30,700

12.5
10,700
42,600

16.0
13,800
54,600

40-36-33

43-40-36

298 x 1,420 x 620


30

48

R410A / R407C / R22 (Nitrogen-Charged for Corrosion-Resistance)


10/9/8
(353/318/282)

13/11/9
(459/388/318)

35

mm

6.35 / 12.7

15/13/11
(530/459/388)

19/16/14
(671/565/494)

55
Flare-Nut Connection (With Flare Nuts)
6.35 / 15.88
9.53 / 15.88

Condensate Drain
0.26

RCD-5.0FSN2

38-34-31

27

Connections

9.53 / 15.88*3)

RCD-4.0FSN2

298 x 860 x 620

kg

m3/min.
Air Flow Rate Hi/Me/Lo (cfm)
Motor

RCD-2.0FSN2
RCD-2.5FSN2
RCD-3.0FSN2
AC 1 , 220-240V / 50Hz, 220V / 60Hz
5.8
7.3
8.3
5,000
6,300
7,100
19,800
25,000
28,200

29/24/21
(1,024/847/742)

34/29/25
(1,201/1,024/883)

35 x 2

55 x 2
9.53 / 15.88*3)

VP25
m3

0.23

0.37

P-N23DWA

P-N46DWA

Silky White
mm

30 x 1,100 x 710

30 x 1,660 x 710

Net Weight

kg

Approximate
Packing Measurement

m3

0.10

0.15

NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions. 1.5 Meters Beneath the Unit.
Voltage of the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. *3) In case of using R407C or R22, use the accessory adaptor and 19.05 piping.

Indoor Units

Indoor Units

In-the-ceiling Type

Ceiling Type

Quiet Operation and Low Height Design for


Limited Space Inside of the Ceiling

Quiet Operation, Easy Installation and


Space-Saving Slim Design
Space-saving Design

Simple Installation and Maintenance

Less than 270 mm in height, this unit can be fit into


practically any previously existing false ceiling or formerly
ducted space without substantial modification (0.82.5HP).

Installation time is much shorter.


*By 30% (Hitachis comparison)

A long-life filter (mildew-proof) is fitted as standard.


No maintenance is required for about 2,500 hours of
operation. *For ordinary offices

Minimum 5mm

Noise and vibration drastically reduced by our


original design.

270mm
(0.8HP ~ 2.5HP)

Broader range of external static pressure.


Flexibly supports a wide range of installation
conditions at site, e.g. longer ducts.

3.0HP model downsized

Amenity improved by auto-louver at air opening.

The width is 250mm Slimmer and the weight 9kg lighter


than the current model, thus delivery and installation is
easier.
9kg
Current Model
New Model

The round, lower part of the air opening complements the


gentle, quiet operation. The auto-louver in the upper part
of the opening automatically controls upward and
downward motion of air flow, while the grille serves as a
shutter when stopped.

Less

In addition to the standard Hi-Me-Lo, the speed-up tap can


be set by remote control. Available for external static
pressure of up to 80 Pa for 0.8-2.5 HP and 170 Pa for 3-5 HP.

15

The large fan and improved resistance of the air-flow


path lower the r.p.m. of the blower, thus reducing noise
and vibration.

False Ceiling

Weight 46kg

Weight 37kg

RPI-1.0FSN2

RPI-1.5FSN2

Indoor Unit Power Supply

Nominal Cooling
Capacity *2)
Nominal Heating
Capacity

kW
kcal/h
Btu/h
kW
kcal/h
Btu/h

2.3
2,000
7,900
2.2
1,900
7,500
2.5
2,100
8,500

2.9
2,500
9,900
2.8
2,400
9,600
3.2
2,800
10,900

Sound Pressure Level


(Overall A Scale)

dB

Dimensions H x W x D

mm

270 x (650+75)
x 720

kg

26

Net Weight
Refrigerant

3
Air Flow Rate Hi/Me/Lo m /min.
(cfm)
External Pressure
Motor
W

Gas
Condensate Drain

Approximate
Packing Measurement

RPI-2.5FSN2

4.1
3,550
14,100
4.0
3,400
13,600
4.8
4,100
16,400

5.8
5,000
19,800
5.6
4,800
19,100
6.3
5,400
21,500

35-33-31

8/7/6
(283/247/212)
60

RPI-3.0FSN2

RPI-4.0FSN2

Heat Exchanger

RPI-5.0FSN2

7.3
6,300
25,000
7.1
6,100
24,200
8.5
7,300
29,000

8.3
7,100
28,200
8.0
6,900
27,300
9.0
7,700
30,700

11.6
10,000
39,700
11.2
9,600
38,200
12.5
10,700
42,600

14.5
12,500
49,600
14.0
12,000
47,800
16.0
13,800
54,600

36-34-32

42-39-35

43-40-36

44-41-37

270 x (900+75)
x 720

RPI-8FSN

RPI-10FSN

350 x (650+75) 350 x (900+75) 350 x (1,300+75)


x 800
x 800
x 800

35
46
37
R410A / R407C / R22 (Nitrogen-Charged for Corrosion-Resistance)

4W, 380-415V / 50Hz,


380V / 60Hz
23.3
29.1
20,000
25,000
79,400
99,200
22.4
28.0
19,300
24,100
76,400
95,500
25.0
31.5
21,500
27,100
85,300
107,500

45(42)*

Downward
Flow

The wireless light receiver kit (option) can be installed


easily through the hole in the lower cover.

Horizontal
Flow

470 x 1,250
x 1,120

mm

6.35

mm

12.7

15.88

m3

0.21

760 (510)* 1,080 (810)*


Brazing Connection
9.53*6)
9.53*6)

9.53

15.88
VP25

15.88*5)

Model
Indoor Unit Power Supply
kW

Nominal Cooling
Capacity *1)

19.05*7)

22.2*8)

Nominal Cooling
Capacity *2)

0.38

0.52

1.060.37

1.06

NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions. 1.5 Meter Beneath the Unit. With Discharge Duct (2.0m) and Return Duct (1.0m).
0.8~5.0FSN2: Voltage of the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1 or 2dB.
8 and 10FSN: Voltage of the power source for the indoor fan motor is 380V. In case of the power source of 415V, the sound pressure level increases by about 2dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The values with ( )* of sound pressure level, air flow rate, external pressure and motor output indicate the values incase of external pressure setting at 110Pa (130Pa for 410V).
4. The data for external pressure *3) indicates "Standard Pressure Setting ( High Pressure Setting - Low Pressure Setting )" values when a filter is not used.
The data for external pressure *4) indicates the values when a filter is not used.
5. *5) In case of using R407C or R22, use the accessory adaptor and 19.05 piping. *6) In case of using R407C or R22, use the accessory reducer and 12.7 piping.
*7) In case of using R407C or R22, use the accessory reducer and 25.4 piping. *8) In case of using R407C or R22, use the accessory reducer and 28.6 piping.

kW
kcal/h
Btu/h
kW

Nominal Heating
Capacity
Sound Pressure Level
(Overall A Scale)

kcal/h
Btu/h

RPC-2.0FSN2

RPC-2.5FSN2

RPC-4.0FSN2

RPC-5.0FSN2

7.3
6,300
25,000

RPC-3.0FSN2
AC 1 , 220-240V / 50Hz, 220V / 60Hz
8.3
7,100
28.200

5.8
5,000
19,800

11.6
10,000
39,700

14.5
12,500
49,600

5.6
4,800
19,100

7.1
6,100
24,200

8.0
6,900
27,300

11.2
9,600
38,200

14.0
12,000
47,800

6.3
5,400
21,500

8.5
7,300
29,000

9.0
7,700
30,700

12.5
10,700
42,600

16.0
13,800
54,600

dB

44-41-38

40-37-34
Silky White

Cabinet Color
Dimensions H x W x D

Net Weight
Refrigerant

mm

210 x 1,100 x 670

210 x 1,320 x 670

270 x 1,320 x 670

270 x 1,580 x 670

kg

26

30

34

42

R410A / R407C / R22 (Nitrogen-Charged for Corrosion-Resistance)

m3/min.
Air Flow Rate Hi/Me/Lo (cfm)
Motor

0.29

kcal/h
Btu/h

100

58

290

General Data

52(50)*

16/14/12
58 (58)*
72 (72)*
19/17/14
37/31/25
13/11/9
15/13/11
27/23/19
(459/388/318) (530/459/388) (565/494/424) (671/600/494) (954/812/671) (1,306/1,095/883) (2,048 (2,048)*) (2,542 (2,542)*)
220 (110)* / 260 (130)* *4)
120 (170-60)*3)
50 (80-30)*3)

0.230.27

While
Stopped

AC 3

75
150
Flare-Nut Connection (With Flare Nuts)
6.35
9.53

Connections
Liquid

RPI-2.0FSN2

AC 1 , 220-240V / 50Hz, 220V / 60Hz

kW
kcal/h
Btu/h

Heat Exchanger

Each part of the system is fully functional.

RPI-0.8FSN2

Nominal Cooling
Capacity *1)

Fan

Fan

Slimmer

General Data
Model

New Model

Current Model

Auto-louver

250mm

Width 650mm

Width 900mm

Improved Resistance of Air-flow Path

14/12/10
(494/424/353)
35

Connections
Liquid / Gas

mm

6.35 / 15.88

18/15/12
(636/530/424)
50
Flare-Nut Connection (With Flare Nuts)
9.53 / 15.88

Condensate Drain

Approximate
Packing Measurement
Standard Accessories

25/21/18
(883/742/636)

33/28/23
(1,165/989/812)

95

135
9.53 / 15.88*3)

VP20
m3

0.30

0.43

0.36

0.50

Mounting Bracket

NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions. 1 Meter Beneath the Unit and 1 Meter from Discharge Grille.
Voltage of the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. *3) In case of using R407C or R22, use the accessory adaptor and 19.05 piping.

16

Indoor Units

Indoor Units

Wall Type

Floor Type

Industry-leading Compactness
Flat Panel at The Front

Slim Design for Perimeter Zone Air Conditioning

Top-Class Compact and Light Weight Design

Space-saving slim unit, only 220 mm in depth.

More Choice to select the installation place thanks to the


reduction of wideness in 2.5,3.0 and 4.0HP

Slim line design only 220 mm in depth, allowing it to be


installed without spoiling the style or beauty of the room.

1,390mm

Effective Use of Space by Window


Conventional Model

With a height of 630 mm, may be installed by a window


leaving plenty of window space. Best installed in a
perimeter zone.

New Model

25%

decreased

1,150mm

User Friendly

Stylish Design and Maintenance


Flat panel is adopted in a front part of all models.
This flat panel also contributes to an easy maintenance.
2.0, 2.5, 3.0 and 4.0HP have been included as new-line-up
of flat panel.

Easy switching from wireless to wired remote controller by


Dip Switch built-in the receiver part.
Direct connection with terminal board is available in 2.0,
2.5, 3.0 and 4.0HP when being connected to wired remote
controller.
All alarm code is displayed when using wireless remote
controller by combining the flashing times of "Timer",
"Filter/Defrosting" (All models).

17

General Data
Model
Indoor Unit Power Supply

11.6
10,000
39,700

2.8
2,400
9,600

4.0
3,400
13,600

5.6
4,800
19,100

7.1
6,100
24,200

8.0
6,900
27,300

11.2
9,600
38,200

Btu/h

3.2
2,800
10,900

4.8
4,100
16,400

6.3
5,400
21,500

8.5
7,300
29,000

9.0
7,700
30,700

12.5
10,700
42,600

dB

38-36-34

40-38-36

41-39-37

kcal/h

kcal/h

Cabinet Color

Net Weight
Refrigerant

280 x 780 x 210


10

kg

m3/min.
Air Flow Rate Hi/Me/Lo (cfm)
Motor

10/8/7
(353/283/247)

295 x 1,030 x 208

11/10/9
(388/353/318)

Standard Accessories

333 x 1,150 x 245

20

mm

6.35 / 12.7

14/12/10
(494/424/353)

18

17/16/14
(600/565/494)

Flare-Nut Connection (With Flare Nuts)


6.35 / 15.88 or 12.7*3)

0.07

0.11

Floor Type

Model

Floor Concealed Type

22/20/17
(777/706/600)

kW

4.1
3,550
14,100
4.0
3,400
13,600

2.9
2,500
9,900
2.8
2,400
9,600

4.1
3,550
14,100
4.0
3,400
13,600

Btu/h

3.2
2,800
10,900

4.8
4,100
16,400

3.2
2,800
10,900

4.8
4,100
16,400

dB

35-32-29

38-35-31

35-32-29

38-35-31

630 x 1,170 x 220

620 x 848 x 220

620 x 973 x 220

kcal/h

Nominal Cooling
Capacity *2)

kcal/h

Btu/h
kW
Btu/h
kW

Nominal Heating
Capacity
Sound Pressure Level
(Overall A Scale)

Net Weight
Refrigerant

kcal/h

0.13

Wall Mounting Bracket

NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on the following conditions measured. 1 Meter Beneath the Unit and 1 Meter from Inlet Grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. *3) The refrigerant piping size may be required to change depending on the outdoor unit to be connected.
If 12.7 pipe is used at the gas side, remove the flare adaptor at the indoor unit gas piping. Then attach the flare nut (accessory) for pipe connection.

Spring White
mm

630 x 1,045 x 220

kg

25

m3/min.
Air Flow Rate Hi/Me/Lo (cfm)
W

8.5/7/6
(300/247/212)
20

Connections
Liquid / Gas

mm

Condensate Drain

Approximate
Packing Measurement

RPFI-1.5FSN2E

2.9
2,500
9,900
2.8
2,400
9,600

Nominal Cooling
Capacity *1)

Motor
9.53 / 15.88

RPFI-1.0FSN2E
RPF-1.5FSN2E
AC 1 , 220-240V / 50Hz, 220V / 60Hz

Indoor Unit Power Supply

Dimensions H x W x D

18

VP16
m3

Special emphasis placed on interior design compatibility as well


as space saving design, allowing it to fit perfectly into the space
below a bay window.

Cabinet Color

30

Condensate Drain
Approximate
Packing Measurement

49-46-43

12
R410A / R407C / R22 (Nitrogen-Charged for Corrosion-Resistance)

Connections
Liquid / Gas

43-40-37

White
mm

So compact that it fits into even a tiny space.

RPF-1.0FSN2E
8.3
7,100
28,200

kW

Dimensions H x W x D

RPK-4.0FSNSM2

7.3
6,300
25,000

Btu/h

Sound Pressure Level


(Overall A Scale)

RPK-3.0FSNSM2

5.8
5,000
19,800

kW

Nominal Heating
Capacity

RPK-2.0FSNSM2
RPK-2.5FSNSM2
AC 1 , 220-240V / 50Hz, 220V / 60Hz

4.1
3,550
14,100

Btu/h

Nominal Cooling
Capacity *2)

RPK-1.5FSNSM2

2.9
2,500
9,900

kcal/h

Compact Design for Limited Space Inside of


Perimeter Wall

General Data
RPK-1.0FSNSM2

kW

Nominal Cooling
Capacity *1)

Floor Concealed Type

m3

0.26

28
19
R410A / R407C / R22 (Nitrogen-Charged for Corrosion-Resistance)
12/10/9
(424/353/318)

8.5/7/6
(300/247/212)

28
20
Flare-Nut Connection (With Flare Nuts)
6.35 / 12.7
18.5 OD
0.29

0.20

23
12/10/9
(424/353/318)
28

0.23

NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
Floor Type: 1.5 Meters from the Unit and 1.5 Meters from Floor Level. Floor Concealed Type: 1.5 Meters from the Unit and 1.5 Meters from the Floor Level.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.

System Equipment

Remote Controllers

Total Heat Exchanger


Provides a Comfortable Environment by
Control Interlocking with Air Conditioning Units

Individual Control
Controllable Using the Remote Control Switch
for The Air Conditioning Unit

Fixed Type Heat Exchanging Element


The newly-developed fixed type heat exchanging element
with high temperature. exchange efficiency equivalent to
the rotor type element, has been adopted for the new total
heat exchangers (Temp Exchange Efficiency: 77%<in case
of 500m3/h type unit>). Additionaly, reliability is increased
due to reduction of moving parts.

Can be controlled in various ways using the remote


control switch for the air conditioning unit (PC-AR).

Automatic Selection of Most Suitable Ventilation Mode


Depending on temperature conditions both outdoors
and indoors, the most suitable ventilation mode is
automatically selected, helping to save energy.

Low weight with Simple Unit Structure: 33kg


(in case of 500m3/h type unit)

Various Control Examples


Standard Connection

Central Station (PSC-5S, PSC-A64S)

3
H-LINK

Example
of
System

SET-FREE
PC-AR

Component of
System

Central Station (PSC-5S, PSC-A64S)


Remote Control Switch (PC-AR)

Hitachi Computer Control Network SystemCS-NET [PSC-6WTX]


4

5
H-LINK

CSNET

PC-AR

Outlook of
System

H-LINK

H-LINK

CSNET

PC-AR

General Data
Model

KPI-2521

KPI-5021

KPI-8021

KPI-10021

AC 1 , 220-240V / 50Hz, 220V / 60Hz

Air Flow Rate

50Hz

m /h

250/250/165

500/500/350

800/800/670

1,000/1,000/870

High/Med/Low

60Hz

m3/h

250/250/150

500/500/300

800/800/660

1,000/1,000/720

External Pressure *1)

50Hz

Pa

65/40/20

150/60/30

140/100/70

160/100/80

High/Med/Low

60Hz

Pa

100/50/20

200/60/20

230/120/80

200/110/60

50Hz

dB

26.5-27.5/25-26/21-22

32.5-33.5/30-31/23.5-24.5

33.5-34.5/32-33/30-31

36-37/34-35/31.5-32.5

60Hz

dB

28.5/25.5/21

32.5/28.5/23

35/31/29

36/34/30

mm

275 x 735 x 780

317 x 1,016 x 888

398 x 1,004 x 1,164

398 x 1,231 x 1,164

Net Weight

kg

21

33

61

72

Approximate Packing
Measurement

m3

0.26

0.46

0.70

0.84

Sound Pressure Level


(Overall A Scale) at
1.5m from the unit
under *2) *3)
High/Med/Low
Dimensions H x W x D

A remote control thermo function is provided.

If a problem occurs, an alarm code immediately


shows the details of the trouble. A self-diagnosis
function is incorporated.

PC-LH3A Wireless Remote Control Switch


No wiring work is required.
Two or more units can be operated simultaneously by remote control.
(*Receiver kit is required.)

NOTES:
*1. Use it under the following conditions. KPI-8021: 29Pa or more, KPI-10021: 49Pa or more
*2. The sound pressure level is based on following conditions.
1.5 Meter beneath the unit and this data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.
*3. The sound pressure level is based on the total heat exchange mode.
In case of the bypass ventilation mode, the sound pressure level is incrased by approximately 1dB(A).

Half-size Remote Control Switch

The main function of this easy-to-use remote


control is temperature setting.

If a problem occurs, an alarm code immediately


shows the details of the trouble.

Suitable for facilities such as hotels, etc.


used by various people.

Use the handy remote control together with CS-NET.

"2 remote controls" or "group control


(for 16 controls max.)" can be used, similarly to
the standard remote control.

When using it with the handy remote control,


set the handy remote control as master and
the half-size remote control as slave.

PSC-A1T 7 Days Timer

Interface and Software by PSC-6WTX (* PCs shall be supplied at site)


Remote Control Switch (PC-AR)

Indoor Unit Power Supply

All the functions of the indoor unit can be


selected by remote control switches.

CSNET

PC-AR

Able to control up to 128 Indoor Units consist of 16 refrigeration series

Component of
System

Timer can be set at half-hour intervals


up to 72 hours.

PC-ARH

Able to control up to 128 Indoor Units


consisting of 16 refrigeration series

Able to control with


PC-AR directly

Remote Control Switch (PC-AR)

Example
of
System

Large LCD

PSC-5S
PSC-A64S

PC-AR

T.H.E+PC-AR

Able to control up to 16 Indoor Units and


Total Heat Exchanger Units

Outlook of
System

Remote Control Switch

PC-AR

UTOPIA

PC-AR

19

:Total Heat
Exchanger (T.H.E)

:Indoor Unit

PC-AR

By using with PSC-5S, PSC-A64S and PC-AR


controllers, the air conditioners controlled by
them can be operated according to a schedule.

Two types of weekly schedule (A and B) can be


set, and can easily be changed for summer and
winter.

The timer can be set at 7-day intervals, and


operation/stop can be set 3 times daily.

Settings are all digitally displayed, allowing


operations and settings to be checked easily.

Remote control can be prohibited in


accordance with the OFF time
(when used with PSC-5S, PSC-A64S and PC-AR).

The power failure backup function prevents the


timer from being stopped by a power failure
lasting up to 2 weeks.

Centralized Control
PSC-5S
PSC-A64S Central Station
By connecting to H-LINK, a group of up to
16(PSC-5S) and 64(PSC-A64S) remote controls
can be used and up to 128 indoor units can be
controlled.
Up to 8 units can be connected to H-LINK.
In addition to the basic functions, the operation
mode and temperature setting,
air quantity or auto louver can be set.

If a problem occurs, an alarm code immediately


shows the details of the trouble.
An external input terminal is provided as
standard. External signals enable the following
functions.
Central operation/stop
Demand control emergency stop
Central operation output
Central alarm output

20

CS-NET

~Hitachi Computer Controlled Network System~

CS-NET is Hitachi's computer control


network system for the SET-FREE VRF,
SET-FREE mini and UTOPIA ranges. The
system is designed to run on Microsoft
Windows 2000 and has the ability to
control up to 16 outdoor units and 128
indoor units per interface. The flexibility
of the SET-FREE system allows the
internal data to be easily accessed and
controlled by the user, with features
including temperature, mode and fan
speed setting and groupings.
R

CS-NET Features
Control Function

Central Station W (PSC-6WTX)

Monitoring Function

By using an HARC40 adapter connectable to a personal computer by USB,


the air conditioners can be centrally controlled.

On/Off Control

On/Off Control

Operation Mode Setting

Operation Mode

Temperature Setting

Set Fan Speed

Air Direction Setting

Set Air Direction

Remote Control Fully


allowed/prohibited

Set Temperature

USB Connection (Field supply)

Filter Sign

Fan Speed Setting


(cannot be set by wireless
remote control)

PCB

Max. 16 Indoor Units


per cycle for 10 and 12HP
outdoor unit and 128 units
per H-LINK in CS-NET system

ID=7

Required system configuration:


Windows 2000; at least 128 MB of RAM;
at least 10 GB of hard disk space

Alarm Code

Air Inlet Temperature

Open Network System (LONWORKS ) for BMS *

2
LONWORKS *
R

HARC 40

P/C

BMS for LONWORKS

H-LINK

HARC70-P1 *3

PCB

PCB

PCB

PCB

fri

ge

ra

nt

Pi

pe

Max. number of indoor units


connectable 8 remote control
groups (max. 120 units)

R
e

Lighting, Elevator, etc.

System Example

Interface
Outdoor Unit

LONWORKS

Transmission Line

H-LINK
Refrigerant Pipe

BMS for LONWORKS

HARC-BX*4

Indoor Unit

*1: An abbreviation of Building Management


System, which is indispensable for building
maintenance.

CS-NET
Remote Controllers

Maximum length of transmission wire for H-LINK is 1,000 meters.


When H-LINK relays(PSC-5HR*) are used, this length is increased
to 2,000 (1 PSC-5HR) ~ 5,000 (4 PSC-5HRs) meters.
Transmission wire can be wired to all units regardless of the
refrigerant system.

Option

*2: "LONWORKS" are trademarks of Echelon


Corporation registered in the United States and
other countries.
*3: Use the PC-AR remote control switch when
using HARC70-P1.
*4: Choose Standard or Options A or B depending
on the control specifications meeting your
needs. For more details, contact your local dealer.
Use the PC-AR remote control switch when
using HARC-BX.

Max. number of indoor units


connectable
Standard specification: 64
Option A spec.: 64
Option B spec.: 32

Lighting, Elevator, etc.


Interface

22

By using the HARC-BX or HARC70-P1 adapter for LONWORKS to connect air conditioners to
the total building control system, air conditioners can be centrally controlled.

H-LINK is a system to connect the control wires for outdoor and indoor units
across two or more refrigerant cycles. Regardless of the branching of
wirings, all the units can be controlled, thus total costs can be reduced.

INK
H-L

PCB

*3: Up to 8 HARC 40 can be connected.

H-LINK System
21

HARC 40*3
ID=0 (Option)

*1: If the number of indoor units per a refrigerant


cycle is 17 or greater, count one outdoor unit
as two units.
*2: Max. total length of transmission wire is
1,000 meters.

Alarm

Filter Sign Resetting

Max. 16*1 Outdoor Units

H-LINK*2

Remote Control Prohibition


Setting

Remote Control Partially


allowed/prohibited

USB Hub
(Field supply)

CS-NET

Optional Parts

~Hitachi Computer Controlled Network System~

Interface (Option)

Indoor Units

You can select the air conditioner control interface depending on


your needs to create a comfortable space.

4-Way Cassette Type


1.0 ~ 2.5

HP

HARC 40

Air Panel

Specifications
Connection Method to
Upper System

Connection by USB (Universal Serial Bus) to PC

Control Item at
Upper System

Monitiring Item at
Upper System

On / Off Control
Air Direction Setting Fan Speed Setting
Operation Mode Setting Remote Control Fully Filter Sign Resetting
Temperature Setting
Air Direction Setting
Allowed/Prohibited
[Cooling :19C ~ 30C
Remote Control Partially (Cannot be set by
Allowed/Prohibited
Heating : 17C ~ 30C]
wireless remote control)
On / Off
Operation Mode
Set Fan Speed
Set Air Direction

Set Temperature
Remote Control
Prohibition Setting
Filter Sign

Alarm
Alarm Code
Air Inlet Temperature

HARC70-P1
Connection Method to
Upper System

3-Way Outlet Parts Set

PI-23LS5

F-23L4-D

Deodorant Filter

F-46L4-D

Filter Box

B-23H4

Antibacterial Long-life Filter

F-23L4-KS

F-23L4-K

1
Fresh Air Intake Kit *

OACI-232

2
T-Pipe Connection Kit *

TKCI-232

Duct Adapter

*3

PD-75 ( 75)

Connection by SNVT (Standard Network Variable Type) to


LONWORKS Network

4.0 and 5.0

1.0 ~ 3.0

HP
Air Panel

P-N46DWA

P-N23DWA

Quantity of Connection 8 Remote Control Groups

By using the HARC70-P1 adapter for


LONWORKS to connect air conditioners
to the total building control system, air
conditioners can be centrally controlled.

PC-ALH

2-Way Cassette Type


Specifications

23

Receiver Kit for Wireless Control

Kit for Deodorant Filter

Quantity of Connection 128 Indoor Units

By using an HARC40 adapter


connectable to a personal computer
by USB, the air conditioners can be
centrally controlled.

3.0 ~ 5.0
P-N23WA

Receiver Kit for Wireless Control

PC-ALHD

Kit for Deodorant Filter

Control Item at
Upper System

On/Off Order
Operation Mode Setting

Temperature Setting
All On/Off Order

Monitiring Item at
Upper System

On/Off State & Alarm


Operation Mode State

Temperature Setting
Individual Thermostat State

24

Deodorant Filter

F-23LD4-D

F-46LD4-D

B-23HD4

B-46HD4

Antibacterial Long-life Filter

F-23LD4-K

F-46LD4-K

1
Fresh Air Intake Kit *

OACID-231

Filter Box

OACID-461

Box Connection Kit *

HARC-BX

In-the-ceiling Type

Specifications
HARC-BX E (Standard)
Connection Method to
Upper System

TBCID-1

HP

Connection by SNVT (Standard Network Variable Type) to


LONWORKS Network

0.8 ~ 1.5

2.0 and 2.5

3.0

4.0

5.0

8.0 and 10.0

Long-Life Filter

F-15LI3C

F-23LI3C

F-23LI3

F-34LI3

F-46LI3

Filter Box

B-15MI3C

B-23MI3C

B-23MI3

B-34MI3

B-46MI3

Drain-up Mechanism Kit

Standard

DUPI-132C

Long-Life Filter Kit

Quantity of Connection 64 Indoor Units


Control Item at
Upper System

On/Off Order
Operation Mode Setting

Temperature Setting
All On/Off Order

Monitiring Item at
Upper System

On/Off State & Alarm


Operation Mode State

Temperature Setting
Individual Thermostat State

DUPI-162
PC-ALHZ

Receiver Kit for Wireless Control

HARC-BX E (Option A)
A HARC-BX can connect to multiple
H-LINK with H-LINK transmission
terminal to 8 PCB.
Points for control and monitor have
been increased to meet more points.
(Points for control and monitor is 8
times larger than HARC70P-1.)
You can select the number of
controls, monitor, and what to control
in the indoor unit from three choices
(Standard, Option A and Option B)
as needed.

Connection Method to
Upper System

Connection by SNVT (Standard Network Variable Type) to


LONWORKS Network

Control Item at
Upper System

On/Off Order
Operation Mode Setting
Temperature Setting

Monitiring Item at
Upper System

On/Off State & Alarm


Inlet Air Temperature

All On/Off Order


Fan Speed Setting
R.C.Sw Permission/Prohibition

HARC-BX E (Option B)
Connection Method to
Upper System

Connection by SNVT (Standard Network Variable Type) to


LONWORKS Network
R

Quantity of Connection 32 Indoor Units


Control Item at
Upper System
Monitiring Item at
Upper System

Floor and Ceiling Types

Quantity of Connection 64 Indoor Units

On/Off Order
Operation Mode Setting
Temperature Setting
On/Off State & Alarm
Operation Mode State
Fan Speed Setting

Fan Speed Setting


R.C.Sw Permission
/Prohibition
Temperature Setting
Louver Position
Alarm Code

All On/Off Order


Louver Position Setting
Inlet Air Temperature
Outlet Air Temperature
Outdoor Air Temperature

HP

RPF(I)
1.0 and 1.5

RPC
2.0 ~ 5.0

Receiver Kit for Wireless Control

PC-ALHZ

PC-ALHP

NOTES:
*1: It is necessary to use the Fresh Air Intake Kit to connect the fresh air intake duct to the unit.
*2: Used when two air intakes( 100 x 2)of the Fresh Air Intake Kit is changed to one air intake ( 150 x 1).
*3: Used when fresh air intake duct are connected to the indoor unit directly.
*4: Used when both of the Fresh Air Intake Kit and Filter Box are used.

DU-M280PIS

Optional Parts
Multi-kits
Applicable Outdoor Unit

RAS-5FSN
RAS-8FSN1
RAS-10FSN1

RAS-12FSN1
RAS-14FSN1
RAS-16FSN1

RAS-18FSN1
RAS-20FSN1
RAS-22FSN1
RAS-24FSN1

RAS-26FSN1
RAS-28FSN1
RAS-30FSN1
RAS-32FSN1

First Branch

Line Branch

First Branch
or
Last Branch

RAS-34FSN
RAS-36FSN
RAS-38FSN
RAS-40FSN
RAS-42FSN

MW-302AN
(E-302SN)
MW-162AN
(E-162SN)

MW-102AN
(E-102SN)

Project Name:

Consultant:

Contractor:

Delivery Date:

System Layout:

MW-242AN
(E-242SN)

MH-84AN
(E-84HSN)

4 Distributions

for 5~8 HP

Header Branch
(First Branch, Last Branch)

MH-108AN
(E-108HSN)

8 Distributions

for 5~10 HP

26

25

Control System
RCIFSN2
Remote Control Switch

PC-AR*1 (Without cable)

Wireless Remote
Control Switch

PC-LH3A

Half-size Remote
Control Switch

PC-ARH*2

7-Day Timer

PSC-A1T

Central Station

PSC-5S, PSC-A64S*3

Remote Control
Cable

PRC-5K,10K,15Kfor PC-AR

3P Connector Cable

PCC-1A

Remote Sensor

THM-R2A

P/C Network
System CS-NET

PSC-6WTX

: Applicable

: Not Applicable

RCDFSN2

RPIFSN(2)

RPCFSN2

NOTES:
*1: As the PC-AR does not include a remote control cable, prepare one in the field, or use PRC-5K, 10K, or 15K.
*2: Make sure that it is used with PC-AR or CS-NET.
*3: Supply 220V or 240V.

RPKFSNSM2

RPF(I)FSN2E