Sunteți pe pagina 1din 41

1.

Shell installation
Installation Shell
First window that pop up
when you insert the
installation CD.
Press Install 800xA
System Installation Shell

Then push Run on the


other windows who are
popping up.

Installation Shell
This will install the system
shell on your computer.

Press Install
If not Microsoft.NET Framework 1.1 is not installed. This system shell wizard will
automatically install this. When this is done system shell is finished with installation

42

2. Automated installation
Automated Installation
Press Run Automated
Installation

System Planner
This is the system planner.
It will make the system you
want for your
network/computers.

Press Next

43

Choose Medium
Choose CD/DVD and push
DVD button in this window

44

System planner wizard

Press Next
Windows
Here you can choose to use
computer with Windows
installed or if you want to
install windows.
If you choose to use
preinstalled Windows read
the System Installation
guide for prerequisites
before installing the
software.
We have used blank pcs
This option makes a silent
installation of Windows on
c:\
Press Next

45

Nodes
The wizard prompts you to
choose a node setup.
We have used single nodes,
this creates the entire
system on one computer.

Click for Single


Engineering Node

Press Next

Connectivity
Choose the device
connectivity. In this system
there is only the AC 800M.

Press Next

46

Field bus
There is no usage of field
bus.

Press Next

Workgroup/Domain
In this system we use
workgroups.

Press Next

47

Summary

Press Next

Installation

Press Next

48

System Configuration
Choose workgroup, service
account,
password(Narvik8515) and
system description.

Press Next

Summary
Use the default settings on
all but password. Choose
an easier password. We
have used abb here.

Press Next

49

Node Name
Write in the name you
want to use for your
node/nodes
Press advanced
If you want to change the
IP-adress of the
node/nodes. This is not
necessary.

Press Next

System configuration IP
Mark the box as shown in
figure.

Press Next

50

System configuration IP
This will show the IPaddress for the node.

Press Next

Summary

Press Next

51

Setup Package
Choose where to store the
package. Use a diskette.

Press Next

Setup Package

Press Next

52

Setup Package
For information about the
setup package click on the
link in the window.

Press Next

Finished
You have now completed the
System Planner and are
ready to start with the
installation of Industrial IT.

Press Finish

53

Computers without Windows


If you are using computer without Windows, or want to reinstall Windows you have to
choose this in the System Planner.
To do a silent installation insert the Windows CD and the diskette created in System
Planner. This will install Windows automatically with the needed configurations on your
local hard drive (c:\). NB: Silent installation will format all data on local hard drive (c:\)
Installing Windows with the help of the disk you have created in System Planner is the
safest way of installing the system. This is because most of the settings needed by
Industrial IT are set automatically.
When using a pre-installed Windows there are a lot of requisites that have to be done to
your system. These are described in the System Installation book.

54

3. Industrial IT Single node installation guide


The installation of Industrial IT on a computer is self-explaining. We have done a single
node installation and created an installation guide. It is very important that you read the
information given in each step, and that you have patience with each step. If you rush
trough the installation and dont let each step finish it might compromise the rest of the
installation.

Required assets for installing Industrial IT on a computer


Windows XP Professional CD
CD/DVD Package from ABB
Administrator rights on the computer
Microsoft Word and Excel 2003 or newer
Diskette with a system created in System Planner
Turn off Windows Firewall and other firewalls that are included in some virus
programs.
Download all hot fixes for your OS from Windows update on the Internet.
This must be done to have a stable and safe OS before you do anymore
installation. Note: This can only be done if you are using computers with preinstalled Windows. If you are using a blank computer you will be prompted to
install hot-fixes during the installation. This should be done.

If the installation should crash there is two ways of starting it again.


Restart PC, and the installation process should continue.
The other way is to manually restart it as shown in figure below.
- Start
- Programs
- ABB industrial IT 800xA
System
- System Installation Shell
-Continue System installation

55

Manual start of installation, this requires a System Planner diskette


- Start
- Programs
- ABB industrial IT 800xA
System
- System Installation Shell
- Setup a new system

Manually Installation
Start

Manually Installation
Start

Click on Browse

56

Manually Installation Start


Browse after the stored
installed package. File
ending *.cct

Press Next

Manually Installation Start


Example:
*.cct file stored on floppy A:\

Press Next

57

Automated installation, this requires a System Planner diskette.


Installation Start
This is the start of the
installation of Industrial It
on your computer.
This will automatically
start when you have done a
silent Windows
installation.

Press Next

Installation Wizard
The wizard shows what is
about to be done.

Press Next

58

Network Settings
On the installation the
network settings from the
diskette will be used.

Press Next

Network Settings
Shows computer name and
network settings.

Press Next

59

Network Checklist

Press Next

Network Checklist

Press Next

60

Restart

Finish

Installation

Press Next

61

Installation Wizard

Press Next

Windows Components

Press Next

62

Checklist Windows

Press Next

Checklist Windows

Press Next

63

Restart

Press Next

Installation Wizard

Press Next

64

Choosing Workgroup
Here you choose the
workgroup you want to
use.

Press Next

Checklist Windows

Press Next

65

Checklist Windows

Press Next

Restart

Press Next

66

Installation Wizard

Press Next

Add Groups
Creating the groups used in
the 800xA program.
Use the default settings.

Press Next

67

Add Users
Setting up the users.

Press Next

Create Service Account


Setting up the service
account in Windows.
Press Advanced
Input password. We have
used Narvik8515.

Press Next

68

Checklist Windows

Press Next

Checklist Windows

Press Next

Insert the IIT800xA-41-1 DVD#1 in the


DVD-rom.

Press OK

69

Installation Wizard

Press Next

System Checker
Gives you general
information about the
system. Also checks if you
have the needed
administrator rights.

Press Next

70

System Checker
Checks if your PC satisfy
the requirements.

Press Next

System Checker
Checks if needed programs
are installed.
Press Install
This has to be done until all
required programs are
installed.

Press Next

Restart the PC

71

Installation Wizard

Press Next

Installation Wizard

Press Next

72

Check user rights

Press Next

Check hardware

Press Next

73

System Checker
Checks if the Windows
components where
installed.

Press Install
If there is a program
missing, press install on it.

Press Next

System Checker
Checks if 3rd programs are
installed.
Press Install
Install the programs
needed.
Press Info
This will give additional
information on the 3rd party
programs needed.

74

WMI SNMP Provider


This message appears
when pressing info.
Follow this to install WMI
SNMP.

WMI SNMP Provider


Mark the Management
and.. as shown in the
figure.
Press Details

75

WMI SNMP Provider


Mark the checkbox as
shown in the figure.
Press OK
Press Next
When Windows
Component Wizard
window opens. This will
install the component.

System Checker

Press Next
When all 3rd party
programs have been
installed1.

Visual Basic 6.0 does not need to be installed at this point.

76

System Checker
Displays the installation
report.

Press Finish

Backup
We have chosen not do
make a backup in the
installation.

Press Skip

77

Install Industrial IT
This is when you start to
install the Industrial IT
software.

Press Install

Choose installation medium


Choose the medium you want to install the
software package from.

Press Cancel

78

Information Box

Press OK

Installation
Write the password you
have chosen in the
password block.

Press Next

79

Installation
Settings that will be
executed.

Press Next

Installation

Press Next

80

Installation
The rest of the steps are
automated.
When installation is
complete, do a restart of
the computer.
The installation takes time
and you should not restart
the computer or start any
other programs while
install.

81

Appendix VI. Post installation


After system installation has been done, your new system must be configured on your
computer. This is a walkthrough of what is necessary to do in the post installation.
Open Post installation document file [6]. Follow this instruction and start Configuration
wizard from the Start menu as shown in Figure 22.

Figure 22 Configuration Wizard start

Configuration wizard window will pop up, as shown in Figure 23


1. Chose Create system, see Figure 23. After choosing your configuration options
the system will configure itself with your options. This configuration will take
approximately 35 minutes. Do nothing on your computer while this is being
installed.
2. Check that connectivity server is running.
3. Check that firmware version in AC 800M controller is similar to the version in the
program Control builder M professional.

Figure 23 Configuration Wizard

82