Sunteți pe pagina 1din 14

Produced on 01.07.2014 with Xpress Selection V6.7.1 - database Central 9.6.

7
Project name
Project address
Reference
Client name
Client address
Revision

1
1
1
1
1
1

Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.

1. Material List
Model
RXYQ16T
RXYQ8T
FXFQ20A
FXFQ25A
KHRQ22M20T
KHRQ22M29T9
KHRQ22M64T
KHRQ22M75T
BRC1E52A/B
BYCQ140DGW1
BHFQ22P1007
BRP2A81
Piping 6,4
Piping 9,5
Piping 12,7
Piping 15,9
Piping 19,1
Piping 22,2
Piping 28,6
Piping 34,9
Total cost

Qty
1
1
26
2
19
2
5
1
28
28
1
1
77,5m
68,0m
87,5m
69,0m
6,0m
6,0m
15,0m
8,0m

Description
Material cost
Heat pump/Heating only VRV IV HP NCH
Heat pump/Heating only VRV IV HP NCH
VRV FXFQ - Round flow cassette 20-125
VRV FXFQ - Round flow cassette 20-125
REFNET branch piping kit
REFNET branch piping kit
REFNET branch piping kit
REFNET branch piping kit
Remote controller
Self cleaning decoration panel
Outdoor unit multi connection piping kit for 2 outdoors
Cool/heat selctor (PCB)

Install. cost Subtotal

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 1

2. Indoor Unit Details


2.1.
Table
Abbreviations
Name
FCU
Tmp C
Rq TC
TC
Rq SC
SC
Tmp H
Rq HC
HC
Suct
Disch
Airflow
Sound
PS
MCA
Fuses
WxHxD
Wght
PI-C 50Hz
PI-C 60Hz
PI-H 50Hz
PI-H 60Hz

of

Logical name of the device


Device model name
Indoor conditions in cooling (dry bulb temp. / RH)
Required total cooling capacity
Available total cooling capacity
Required sensible cooling capacity
Available sensible cooling capacity
Indoor temperature in heating
Required heating capacity
Available heating capacity
Suction temperature
Discharge temperature
Supplied airflow
Sound pressure low and high
Power supply (voltage and phases)
Minimum Circuit Amps
Fuses
WidthxHeightxDepth
Weight of the device
Power input in cooling at 50Hz
Power input in cooling at 60Hz
Power input in heating at 50Hz
Power input in heating at 60Hz

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

2.2. Out 1 - RXYQ24T


Actual capacity data at conditions and connection ratio (95%) as entered
Name
Ind 2
Ind 3
Ind 1-1
Ind 1-2
Ind 5-1
Ind 4
Ind 6-1
Ind 6-2
Ind 6-3
Ind 5-2
Ind 7
Ind 8
E02
E03-1
E03-2
E05-1
E01-1
E01-2
E01-3
E04
E06-1
E06-2
E05-2
E07-1
E07-2
E07-3
E06-3
E06-4

FCU
FXFQ20A
FXFQ25A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ25A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A
FXFQ20A

Tmp C
C
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%
25,0 / 50%

Rq TC

TC

kW
kW
1,8
2,1
2,1
2,6
1,8
2,1
1,8
2,1
1,2
2,1
1,5
2,1
1,5
2,1
1,5
2,1
1,5
2,1
1,2
2,1
1,8
2,1
2,3
2,6
2,0
2,1
1,2
2,1
1,2
2,1
1,3
2,1
1,5
2,1
1,5
2,1
1,5
2,1
1,5
2,1
1,5
2,1
1,5
2,1
1,3
2,1
1,5
2,1
1,5
2,1
1,5
2,1
1,5
2,1
1,5
2,1

Rq SC

SC

kW
kW
n/a
1,6
n/a
1,9
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,9
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6
n/a
1,6

Tmp H
C
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0
21,0

Rq HC

HC

kW
kW
1,5
2,4
2,3
3,1
1,5
2,4
1,5
2,4
1,5
2,4
2,3
2,4
1,0
2,4
1,0
2,4
1,0
2,4
1,5
2,4
1,5
2,4
1,5
3,1
1,5
2,4
1,2
2,4
1,2
2,4
1,5
2,4
1,0
2,4
1,0
2,4
1,0
2,4
1,0
2,4
1,0
2,4
1,0
2,4
1,5
2,4
1,0
2,4
1,0
2,4
1,0
2,4
1,0
2,4
1,0
2,4

Discharge temperature
Name

Ind 2
Ind 3
Ind 1-1
Ind 1-2
Ind 5-1
Ind 4
Ind 6-1
Ind 6-2
Ind 6-3
Ind 5-2
Ind 7
Ind 8
E02
E03-1
E03-2

Condition 1

Condition 2

Suct Disch Airflow Suct Disch Airflow


C
C
l/s
C
C
l/s
18,0
24,1
208
21,0
28,1
208
18,0
25,6
208
21,0
29,9
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
25,6
208
21,0
29,9
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Name

E05-1
E01-1
E01-2
E01-3
E04
E06-1
E06-2
E05-2
E07-1
E07-2
E07-3
E06-3
E06-4

Condition 1

Condition 2

Suct Disch Airflow Suct Disch Airflow


C
C
l/s
C
C
l/s
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208
18,0
24,1
208
21,0
28,1
208

Condition 1: The discharge temperature is calculated for an ambient temperature of -15,0C and a room
temperature of 18,0C, as specified in the Preferences window. It also uses the maximum connection ratio of
the installation and the corresponding fan speed of the indoor units.
Condition 2: The discharge temperature is calculated using the design ambient temperature 0,0C, a
room temperature of 21,0C and an operational connection ratio of maximum 130%.
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure
a thermal comfort level.
The discharge temperature of condition 2 is lower than 35,0C. Reducing the connection ratio may compensate this
and may raise the discharge temperature improving the thermal comfort level.
Name
Ind 2
Ind 3
Ind 1-1
Ind 1-2
Ind 5-1
Ind 4
Ind 6-1
Ind 6-2
Ind 6-3
Ind 5-2
Ind 7
Ind 8
E02
E03-1
E03-2
E05-1
E01-1
E01-2
E01-3
E04
E06-1
E06-2
E05-2
E07-1
E07-2
E07-3
E06-3

Sound
dBA
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31
28-31

PS
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph
220V 1ph

MCA
A
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3
0,3

Fuses
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std
Factory Std

WxHxD
mm
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840
840x204x840

Wght
kg
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

PI-C 50Hz

PI-C 60Hz

PI-H 50Hz

PI-H 60Hz

kW
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038

kW
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038

kW
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038

kW
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038
0,038

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Name
E06-4

Sound
PS
dBA
28-31
220V 1ph

MCA
Fuses
A
0,3 Factory Std

WxHxD
mm
840x204x840

Wght PI-C 50Hz PI-C 60Hz PI-H 50Hz PI-H 60Hz


kg
kW
kW
kW
kW
20
0,038
0,038
0,038
0,038

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

3. Outdoor Unit Details


3.1.
Table
Abbreviations

of

Name
Model
Comb
Tmp C
CC
Rq CC
EER
ESEER
Tmp H
HC
Rq HC
COP
Piping
Bse Refr

Logical name of the device


Device model name
Connection ratio
Outdoor temperature in cooling
Available cooling capacity
Required cooling capacity
EER at selection and nominal conditions
European Seasonal Energy Efficiency Ratio
Outdoor conditions in heating (dry bulb temp. / RH)
Available heating capacity (integrated heating capacity)
Required heating capacity
COP at selection and nominal conditions
Largest distance from indoor unit to outdoor unit
Standard factory refrigerant charge (5m actual piping length)
excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook
Ex Refr
Extra refrigerant charge
PS
Power supply (voltage and phases)
MCA
Minimum Circuit Amps
MFA
Maximum Fuse Amps
Run Amps Running Amps
St Curr
Starting current
Fuses
Fuses
WxHxD
WidthxHeightxDepth
Wght
Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

3.2. Outdoor Details


Name

Model

Comb
%

Out 1
Name

RXYQ24T
Model

95

Tmp C

CC

C
32,0

PS

kW
57,3

MCA
A

Out 1

RXYQ24T 400V 3Nph


* RXYQ16T
* RXYQ8T

Rq CC

31,5
18,5

EER

kW
43,5kW

ESEER

4,2 / 3,7

MFA Run Amps St Curr


A
40
20

A
21,3
7,5

6,8

Tmp H

HC

C
0,0 / 50%

kW
50,8

Fuses

Rq HC
kW
36,0kW

COP
2,8 / 4,1

WxHxD

Wght

mm

kg

cfr. local legislation 1240x1685x765


cfr. local legislation 930x1685x765

Piping
m
55,0

Bse Refr

Ex Refr

kg
16,3

kg
11,0

316
187

Sufficient distance should be respected between the modules according to the service & operation space rules
as mentioned in the databook.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

3.2.1. Out 1 - RXYQ24T


Model
RXYQ24T
FXFQ20A
FXFQ25A
KHRQ22M20T
KHRQ22M29T9
KHRQ22M64T
KHRQ22M75T
BRC1E52A/B
BYCQ140DGW1
BHFQ22P1007
BRP2A81
Piping 6,4
Piping 9,5
Piping 12,7
Piping 15,9
Piping 19,1
Piping 22,2
Piping 28,6
Piping 34,9
Total cost

Qty
1
26
2
19
2
5
1
28
28
1
1
77,5m
68,0m
87,5m
69,0m
6,0m
6,0m
15,0m
8,0m

Description
Material cost
Heat pump/Heating only VRV IV HP NCH
VRV FXFQ - Round flow cassette 20-125
VRV FXFQ - Round flow cassette 20-125
REFNET branch piping kit
REFNET branch piping kit
REFNET branch piping kit
REFNET branch piping kit
Remote controller
Self cleaning decoration panel
Outdoor unit multi connection piping kit for 2 outdoors
Cool/heat selctor (PCB)

Install. cost Subtotal

Standard factory refrigerant charge (5m actual piping length) = 16,3kg


Extra refrigerant charge = 0,0 + 1,7 + 77,5m(6,4) x 0,022 + 68,0m(9,5) x 0,059 + 13,0m(15,9) x 0,18 + 10,0m(12,7)
x 0,12 = 11,0kg
Piping Limitations
Connected indoor type(s): VRV
Maximum total length
Maximum longest actual length
Maximum longest equivalent length
Maximum main pipe length (size up of main pipe required if longer)
Maximum length first branch to last branch (size up of intermediate pipes required if longer)
Maximum length first branch to indoor units
Maximum length of indoor units to nearest branch
Maximum length difference between longest and shortest distance to indoor units
Maximum height difference, outdoor unit below indoor units
Minimum connection ratio, outdoor unit below indoor units
Maximum height difference, outdoor unit above indoor units
Minimum connection ratio, outdoor unit above indoor units
Maximum height difference in technical cooling, outdoor unit below indoor units
Maximum height difference in technical cooling, outdoor unit above indoor units
Maximum height difference between indoor units
Connection ratio range
Refrigerant pipe diameters
Maximum equivalent length from BP unit or VRV indoor to VRV REFNET (size up of intermediate pipes required
if longer)
Maximum equivalent length from BP unit or VRV indoor to VRV REFNET

1000,0m
165,0m
190,0m
90,0m
40,0m
90,0m
40,0m
40,0m
90,0m
110%
90,0m
80%
40,0m
90,0m
30,0m
50-130%
15,9 (liquid) x 34,9 (gas)
40,0m

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

90,0m

Pipe Capacities
Maximum Connection Index
149,9
199,9
289,9
419,9
639,9
> 639,9
Main pipe size up

Diameters
9,5x15,9
9,5x19,1
9,5x22,2
12,7x28,6
15,9x28,6
19,1x34,9
19,1x34,9

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

4. Piping Diagrams
Pipes marked with * in the diagrams must be connected to the device with a reducing joint.

4.1. Piping Out 1


Out 1
RXYQ24T RXYQ16T
RXYQ8T

12,7x28,6

9,5x19,1

BHFQ22P1007
8,0m
15,9x34,9 *

2,0m
15,9x28,
6
KHRQ22M75T

3,0m
15,9x28,
6
KHRQ22M64T

3,0m
12,7x28,
6
KHRQ22M64T

5,0m
12,7x28,
6
KHRQ22M64T

2,0m
4,0m
2,0m
3,0m
3,0m
12,7x28,
9,5x22,
9,5x22,
9,5x19,
9,5x19,
6
2
2
1
1
KHRQ22M64T
KHRQ22M64T
KHRQ22M29T9
KHRQ22M29T9

2,0m
9,5x15,
9
KHRQ22M20T

1,0m
9,5x15,
9
KHRQ22M20T

2,0m
9,5x15,
9
KHRQ22M20T

1,0m
6,4x12,7
KHRQ22M20T

KHRQ22M20T

Ind 2
FXFQ20A
5,0m
6,4x12,7
4,0m
6,4x12,
7

5,0m
9,5x15,9

Ind 3
FXFQ25A

KHRQ22M20
T

1,0m
6,4x12,
7

Ind 1-1
FXFQ20A

4,0m KHRQ22M20
9,5x15,9 T

Ind 1-2
FXFQ20A
1,0m
6,4x12,7
Ind 5-1
FXFQ20A

4,0m
6,4x12,7

1,0m
6,4x12,
7

3,0m
9,5x15,9

Ind 4
FXFQ20A

KHRQ22M20
T

Ind 6-1
FXFQ20A
4,0m
6,4x12,7
Ind 6-2
FXFQ20A

5,0m
6,4x12,7

2,0m
9,5x15,9
KHRQ22M20T
KHRQ22M20T

1,0m
6,4x12,
7

Ind 6-3
FXFQ20A

3,0m
9,5x15,9

Ind 5-2
FXFQ20A
6,0m
6,4x12,7
Ind 7
FXFQ20A

6,0m
6,4x12,7

Ind 8
FXFQ25A

5,0m
6,4x12,7

1,0m
6,4x12,
7

2,0m
9,5x15,9

E02
FXFQ20A

KHRQ22M20
T

E03-1
FXFQ20A
4,0m
6,4x12,7
1,0m
6,4x12,
7

8,0m
9,5x15,9

E03-2
FXFQ20A

KHRQ22M20
T

1,0m
6,4x12,
7

E05-1
FXFQ20A

4,0m KHRQ22M20
9,5x15,9 T

2,0m
6,4x12,
7

E01-1
FXFQ20A

3,0m KHRQ22M20
9,5x15,9 T

E01-2
FXFQ20A
3,0m
6,4x12,7
E01-3
FXFQ20A

5,0m
6,4x12,7

1,0m
6,4x12,
7

3,0m
9,5x15,9

E04
FXFQ20A

KHRQ22M20
T

E06-1
FXFQ20A
3,0m
6,4x12,7
1,0m
6,4x12,
7

3,0m
9,5x15,9

E06-2
FXFQ20A

KHRQ22M20
T

3,0m
6,4x12,
7

E05-2
FXFQ20A

7,0m KHRQ22M20
9,5x15,9 T

1,0m
6,4x12,
7

E07-1
FXFQ20A

1,0m KHRQ22M20
9,5x15,9 T

E07-2
FXFQ20A
3,5m
6,4x12,7
1,0m
6,4x12,7

3,0m
9,5x15,9

KHRQ22M20
T

E07-3

FXFQ20A
E06-3
FXFQ20A
3,0m
6,4x12,7

E06-4
FXFQ20A

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook.
F1F2 = Please select the cable type and size in accordance with the databook.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

5.1. Wiring Out 1


Out 1
RXYQ24T
RXYQ16T

IN F1,F2

F1,F2

P1,P2

Ind 3
FXFQ25A

32A
3Nph

P1,P2

BRC1E52A/
BRC1E52A/
B

L,N 0,3A
1ph

Q1,Q2

RXYQ8
T

L1,L2,L3,N
19A
3Nph

F1,F2

Ind 1-1
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

Ind 1-2
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

Ind 5-1
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

Ind 4
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

Ind 6-1
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

Ind 6-2
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

Ind 6-3
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

Ind 5-2
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

Ind 7
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

Ind 8
FXFQ25A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E02
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E03-1
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E03-2
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E05-1
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E01-1
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E01-2
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E01-3
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E04
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E06-1
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E06-2
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E05-2
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E07-1
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E07-2
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

E07-3
FXFQ20A

P1,P2

BRC1E52A/
B

L,N 0,3A
1ph

F1,F2

F1,F2

P1,P2
P1,P2

BRC1E52A/
BRC1E52A/B

E06-4
FXFQ20A
F1,F2

L,N

0,3A 1ph

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

6. Device Options
6.1. Outdoor Unit Options
Model
Description
Used by
BRP2A81
Cool/heat selctor (PCB)
Out 1 [RXYQ24T]
BHFQ22P1007 Outdoor unit multi connection piping kit for 2 outdoors Out 1 [RXYQ24T]

6.2. Indoor Unit Options


Model
Description
Used by
BYCQ140DGW1 Self cleaning decoration panel Ind 1-1 [FXFQ20A]
Ind 3 [FXFQ25A]
Ind 5-2 [FXFQ20A]
Ind 6-3 [FXFQ20A]
E01-1 [FXFQ20A]
E02 [FXFQ20A]
E04 [FXFQ20A]
E06-1 [FXFQ20A]
E06-4 [FXFQ20A]
E07-3 [FXFQ20A]

Ind 1-2 [FXFQ20A]


Ind 4 [FXFQ20A]
Ind 6-1 [FXFQ20A]
Ind 7 [FXFQ20A]
E01-2 [FXFQ20A]
E03-1 [FXFQ20A]
E05-1 [FXFQ20A]
E06-2 [FXFQ20A]
E07-1 [FXFQ20A]

Ind 2 [FXFQ20A]
Ind 5-1 [FXFQ20A]
Ind 6-2 [FXFQ20A]
Ind 8 [FXFQ25A]
E01-3 [FXFQ20A]
E03-2 [FXFQ20A]
E05-2 [FXFQ20A]
E06-3 [FXFQ20A]
E07-2 [FXFQ20A]

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

S-ar putea să vă placă și