Sunteți pe pagina 1din 126

770-798-2423

dstallworth@ofsoptics.com

David Stallworth

FTTH Fundamental Planning


and Design

(RF OVER GLASS)

and
RFOG

(Fiber to the Home/Premise/x


GPON, BPON, EPON)

This presentation applies to


FTTH

Lets say you are going to place FTTx to


all living and business units
in the city below :

Or you are going to place cable


in a new development:

Where should the splitters be placed?

Where should the feeder boundaries be placed?

Where do the branch feeder routes go?

Where should the feeder routes be placed?

How many feeder routes?

Where should the hub/headend/


central office be placed?

CENTRALIZED OR
DISTRIBUTED SPLITTER

SPLITTER
CONNECTORS

DROP CONNECTORS

PON DISTRIBUTION
CABLE
FIBER
TERMINATION

CENTRALIZED CABINET
FEEDER CABLE

HEADEND
ELECTRONICS
(Optical Line
Card)

ARE THERE ANY OTHER FACTORS


TO CONSIDER?

ARE THERE ANY RELATIONSHIPS


BETWEEN COSTS?

WHAT ARE ALL THE COSTS TO CONSIDER?

CUSTOMER
END
ELECTRONICS

FIBER DROP

PON DROP
CLOSURES

ABOVE OR BELOW GROUND


INFRASTRUCTURE

CONTRACTOR PLACING COST

GEOGRAPHY

CUSTOMER TAKE RATE

OTHER FACTORS TO CONSIDER:

Your Dynamics matter:


Take Rate
Labor Rate
Housing Density

FUSION SPLICING

S P L IT T E R L O C A T IO N

D RO P C O NTR A C T C O STS

F IB E R D R O P

PON DROP CLOSURES

P O N D IS T R IB U T IO N
CABLE

PON DESIGN

HELP!

FEEDER CABLE

DISTRIBUTED SPLITTERS

SPLITTER LOCATION

CENTRALIZED CABINET

TAKE RATE

HEADEND ELECTRONICS

INSTALLATION LABOR

DROP
CONNECTORS

CONSTRUCTION LABOR

SPLITTER
CONNECTORS

WE NEED A WAY TO DECIDE


WHAT DESIGN IS BEST

WE NEED A WAY TO EXAMINE


THOSE RELATIONSHIPS TOGETHER

OPTICOST MODELS
PROVIDE
THE ANSWER

study technique)

(classic cost

Ideal Location?

CABINET AREA SIZE TO STUDY:


1 PON UP TO 32 PONS PER CABINET AREA
OR 32 TO 1024 LIVING UNITS

TOTAL AREA HAS


2048 LIVING UNITS
AND 64 PONS

EACH SQUARE IS
500 LONG AND
500 WIDE

EACH SQUARE IS
A 32 HOME PON

AN IDEAL AREA

Drop Closure

Pedestal
(Drop
Closure)

Drop Cable

Buried Distribution Cable


Drop Closure

Centralized Cabinet Locations


Locations

Central Office / Head End

Aerial
Distribution
Cable

MDU
Termination

MDU

Residential

Family

Single

OFS OptiCost Models


Guidelines for selecting the right solution

Where should the hub/headend/


central office be placed?

10

10

10

10

Ideal Hub/Node Placement

Cost

50

100

150

200

250

300

350

400

Cost variance from ideal

Variance from Ideal

Cost increase
from Ideal

Ideal Hub/Node Placement

20 km

Serving Area Boundary

Place in geographical center

Hub/
Node

Why?
Provide 20km reach to all subscribers

Ideal Hub/Node Placement

Serving Area Boundary

Place in living unit density center

Hub/
Node

Why?
Minimize cable lengths
and sizes

Ideal Hub/Node Placement

20 km

Serving Area Boundary

Place in living unit density center

Place in geographical center

Hub/
Node

Why?
Provide 20km reach to all subscribers

Why?
Minimize cable lengths
and sizes

Ideal Hub/Node Placement

20 km

Serving Area Boundary

Place in living unit density center

Place in geographical center

Hub/
Node

Determine the optimum mix


of geographical and density center

Ideal Hub/Node Placement

Ideal Location

What about new developments:

Ideal Hub/Node Placement

Generally, Density Center is more critical

Ideal Location

The same methods apply to developments:


Geographical center
and Density center

Ideal Hub/Node Placement

Phase 2

Use best location available- not at the front

Phase 3

The problem:
Developments built in phases

Ideal Hub/Node Placement

Phase 1

Where should an Optical


Splitter Cabinet be placed?

THE IDEAL PLACE IS IN THE MIDDLE


OF THE AREA THE CABINET WILL
SERVE

10
32 HOME
PON AREAS

SPLITTER CABINET- WHERE TO PLACE IT

MULTIPLE CABINET PLACEMENT

USE
160 HOME
CABINET

10
32 HOME
PON AREAS

How big should the cabinet be?


How many homes served from one
cabinet?

TOTAL AREA HAS


2048 LIVING UNITS
AND 64 PONS

EACH SQUARE IS
500 LONG AND
500 WIDE

EACH SQUARE IS
A 32 HOME PON

AN IDEAL AREA

256
Homes/
cabinet

512
Homes/
cabinet

1024
Homes/
cabinet

32
Homes/
cabinet

64
Homes/
cabinet

128
Homes/
cabinet

6 CABINET SIZE PLANS

Cost Models studies various cabinet sizes

Cabinet Size:

Overall Costs

1024

512

128

Cabinet Size

256

64

256 Living Units


32

Ideal Cabinet size =

ideal Cabinet Size

Cabinet Size:

$/S UB

500

1000

1500

2000

2500

3000

3500

PLAN NUMBER

TAKE RATE ANALYSIS

100%

90%

80%

70%

60%

50%

40%

35%

30%

20%

10%

200
100

400
300

600
500

800
700

900

MDUs
6

500'
3

1028
512
256
128
64
32

0.6

0.3

0.2

1000' 1500' 2000' 3000' PON Size

Single Family

700'

Typical Urban/Suburban Developments


Are 6-8 Homes per Acre for Single Family

15

100' 300'

CABINET SIZE & HOUSING DENSITY

Homes/ Acre 139

COST PER SUB

6. MOST ECONOMICAL SIZE CENTERS AROUND 256 WHEN ALL


FACTORS ARE CONSIDERED
(MOST SENSITIVE TO TAKE RATE, PON SIZE, CABINET COST)

5. CABINET COST IS MODERATELY SENSITIVE WHEN SELECTING


CABINET SIZE (CONSIDER $/LIVING UNIT FOR EACH SIZE)

4. TAKE RATE IS VERY SENSITIVE WHEN SELECTING CABINET SIZE

3. CO ELECTRONICS COST ARE FAIRLY INSENSITVE WHEN


SELECTING CABINET SIZE

2. SPLITTER COST ARE FAIRLY INSENSITIVE WHEN SELECTING


CABINET SIZE

1. PON AREA SIZE IS MODERATELY SENSITIVE:


BIGGER PONS PUSHES IDEAL SIZE SMALLER
SMALLER PONS PUSHES IDEAL SIZE BIGGER

CONCLUSIONS

even for an optimistic take-rate, it is optimal to


aggregate about 192-224 homes (6-8 splitters) in an
urban deployment and 96-128 homes in a rural
deployment. In the urban context, the lowest cost
architecture taking into account the additional
fiber related costs and OLT port savings has an
OFAP (Optimal Fiber Aggregation Point) size of
about 200 homes.

Anupam Banerjee, Marvin Sirbu


Carnegie Mellon University
Pittsburgh, PA
Towards Technologically and Competitively
Neutral Fiber to the Home (FTTH) Infrastructure

OUTSIDE VALIDATION:

Where should the feeder boundaries be


placed?

Where do the branch feeder routes go?

Where should the feeder routes be


placed?

How many feeder routes?

CO OR
HEADEND

MAIN
FEEDER

BRANCH
FEEDER

FEEDER DESIGN
Definitions

CO OR
HEADEND

FEEDER

FEEDER
BOUNDARY

IDEAL FEEDER DESIGN

10

10

10

10

Ideal Hub/Node Placement

Cost
0

50

100

150

200

250

300

350

400

Cost variance from ideal

Variance from Ideal

Ideal Hub/Node Placement

Cost increase
from Ideal

Ultimate needs

Design for the

At least 10 years

Design to last

CO OR
HEADEND

MAIN
FEEDER

BRANCH
FEEDER

FEEDER DESIGN
Definitions

Where to place the


optical splitter?

For FTTH:

IDEAL FEEDER DESIGN

Decentralized/
Distributed

Centralized

Home Run

Where should the splitter be placed?

Economic Justification

splitters in a cabinet

When to place optical

Cabinet

At what
Cost?

Optical Line Card (OLT)

Use

Efficiently

Centralized

Economic Reasons
to place a Cabinet

O
N
T
O
N
T

O
N
T
O
N
T

O
N
T

O
N
T

O
N
T

O
N
T

O
N
T

O
N
T
O
N
T

O
N
T

O
N
T

O
N
T

ONT ON SIDE OF HOUSE

20 HOMES

O
N
T

75% TAKE RATE

TAKE RATE = 15 / 20 OR

15 HOUSES TAKE SERVICE OF SOME TYPE

O
N
T

TAKE RATE
DEFINITION

$ P E R S U B S C R IB E R

2400
2200
2000
1800
1600
1400
1200
1000
800
600
400
200
0

100

90

80

INCREMENTAL
ELECTRONICS $/SUB

70

50
TAKE RATE %

60

40

ELECTRONICS VERSUS CENT. CABINET COMPARISON

30

20

10

200

400

600

800

1000

1200

$ P E R S U B S C R IB E R

100

90

CENT. CABINET
$/SUB

80

70

TAKE RATE %

60

50

ELECTRONICS VERSUS CENT. CABINET COMPARISON

40

30

20

10

1200

1400

1600

200

400

600

800

1000

$ PER SUBSCRIBER

100

90

CENT. CABINET
$/SUB

INCREMENTAL
ELECTRONICS $/SUB

80

70

60
50
TAKE RATE %

40

30

ELECTRONICS VERSUS CENT. CABINET COMPARISON

20

When to use splitter cabinets

10

LOW

100

HOUSING DENSITY

HIGH

90

80

60

TAKE RATE

70

50

40

30

CABINETS

20

SPLITTERS IN

8 KFT

Economic Splitter Location


DISTANCE FROM HEADEND

Economic Justification

or

Cabinet or Headend/Node

Optical Splitters in a

6000
1-12 fiber cable

6000

1000
1-12 fiber cable

PLAN 3- FIELD SPLITTERS

1 shelf to terminate
12 fibers

1 shelf to terminate
12 fibers

Central Office

6000
2-144 fiber cables

9-1x32 splitters
Cent. Cabinet

9-1x32 splitters
In field in drop
closures

PLAN 2- FIELD SPLITTERS

Bay to terminate
288 fibers

Central Office

Shelf with 9
x32 splitters

Central Office

PLAN 1- CO SPLITTERS

3 Options for Splitter


Placement:

288
homes

288
homes

288
homes

$/S u b

20

40

60

80

100

1000'

2000'

3000'
4000'
Distance to CO

5000'

CO vs. Centralized Splitters

CO VS. CABINETS

Centralized
Cabinet
Cost

CO Splitter
Cost

DISTANCE TO CO

8KFT

CABINETS

CO

SPLITTERS IN

SPLITTERS IN

Valid for take rates <50% only

CO vs. CABINETS

LOW

100

HOUSING DENSITY

HIGH

90

80

60

TAKE RATE

70

50

40

CO
30

20

SPLITTERS IN

CABINETS

SPLITTERS IN

8 KFT

Economic Splitter Location


DISTANCE FROM HEADEND

Economic Justification

or

or Distributed

Cabinet /Headend/Node

Optical Splitters in a

Packaged PLC splitter


with robust fiber cordage
helps prevent damage during
installation

Closure
Assembly

This holder designed


to hold splitters

Closure Trays

Ruggedized PLC Splitter in


Closure
Protects Splitter for durability and
field handling

DISTRIBUTED SPLITTING
DESIGN
STEP:
DEFINE
PON AREAS

CONFIDENTIAL
AND PROPRIETARY
PROPERTY OF BUCKEYE CABLEVISION INC.
DO NOT DISTRIBUTE OR DUPLICATE

STEP:
DETERMINE
SPLITTER
LOCATIONS

CONFIDENTIAL
AND PROPRIETARY
PROPERTY OF BUCKEYE CABLEVISION INC.
DO N OT DISTRIBUTE OR DUPLICATE

STEP:
DETERMINE
FIBER CABLE
ROUTES AND
SIZES

CONFIDENTIAL
AND PROPRIETARY
PROPERTY OF BUCKEYE CABLEVISION INC.
DO NOT DISTRIBUTE OR DUPLICATE

6000
2-144 fiber cables

1 shelf
terminate
1 shelf
to to
terminate
1212
fibers
fibers

6000
1000
1-12
fiber
cable
1-12
fiber
cable
9-1x32
splitters
9-1x32
splitters
Cabinet
InCent.
field in
drop
closures

PLAN
FIELD
SPLITTERS
PLAN
3- 2FIELD
SPLITTERS

Bay to terminate
288 fibers

Central
Office
Central
Office

Shelf with 9
1x32 splitters

Central Office

PLAN 1- CO SPLITTERS

CO vs. SPLITTERS IN
EACH PON
(DISTRIBUTED)

288
288
homes
homes

288
homes

DISTANCE TO CO

EACH PON

SPLITTERS IN

Valid for take rates >50% only

CO vs. SPLITTERS IN
EACH PON

8KFT

1200

1400

1600

200

400

600

800

1000

$ P E R S U B S C R IB E R

100

90

CENT. CABINET
$/SUB

INCREMENTAL
ELECTRONICS $/SUB

80

70

60
50
TAKE RATE %

40

30

ELECTRONICS VERSUS CENT. CABINET COMPARISON

20

10

LOW

100

HOUSING DENSITY

HIGH

90

80

60

TAKE RATE

70

EACH PON

SPLITTERS IN

50

40

CO
30

20

SPLITTERS IN

CABINETS

SPLITTERS IN

8 KFT

Economic Splitter Location


DISTANCE FROM HEADEND

Home
Run
1
2
2
2

Issue

Upgrade

New Install

Troubleshoot

Reliability

Centralized Distributed

Operational Concerns:

Density

Labor Rate

inside the PON Area:

Fundamental Design

2 factors affect

DAP Design
(inside 32 home PON area)

Cost Model Studied all variations

Labor Rate:

PON Design
(inside 32 home PON area)

250

300

Fusion Spliced $65/HR

Connectors on Drop

SplicedDouble
SplicedQuad

Direct- Mid
Split
Spliced

Direct Feed

Conventional

PON Cabling Drop Connectors Versus Fusion Splicing


$65/HR

Labor Rate Analysis

Conclusion:
Conventional Design is the most economical
when fusion splicing is used
up to a labor rate of $65-75/hr

50

100

150

200

$/SUBSCRIBER

Design?

Housing Density affect

How does

PON Design
(inside 32 home PON area)

Housing Density:

Least Dense: Rural


Areas

Subdivisions

Normal Density:

High Rises

Apartments

Most Dense:

Housing Density:

High Rises

OSP
Closure

Cable

Riser

Combiner

FDH

Drop

Terminal

ONT

Floor

Ceiling

Drop Cable

Terminal

Combiner

FDH

Four Components:

Installs very quickly

Minimizes impact on riser space

cabling:

Advantages over conventional

High Rise PON: Aggregation Architecture

FDH

Housing Density:

apartments)

(campus-style

Units (MDU)

Multi- Dwelling

IDEAL MDU DEVELOPMENT

LOOPED CABLE TO EACH BUILDING

DEDICATED CABLE TO EACH BUILDING

400

200

100

90

80

70

50
TURNOVER %

60

TRUCK ROLL

40

ADD'L ELECTRONICS
$/SUB

30

20

10

TRUCK ROLL COST VERSUS ELECTRONICS INCREMENTAL COST

600

$ PER SUBSCRIBER

4. BUILDING SIZE IS SLIGHTLY SENSITIVE TO SELECTING


AN APPROPRIATE DESIGN PLAN

3. DISTANCE IS SLIGHTLY SENSITIVE TO SELECTING


AN APPROPRIATE DESIGN PLAN

2. IF LOOPING THE CABLE IS IMPRACTICAL, THE SECOND BEST


PLAN IS WITH DEDICATED CABLES SERVED
FROM A 1X32 SPLITTER

1. THE MOST ECONOMICAL PLAN IS TO LOOP THE CABLE


BETWEEN BUILDINGS WITH A 1X32 FEEDING THE BUILDINGS.

MDU CONCLUSIONS

Housing Density:

Subdivisions

Normal Density:

Cost Model Studied all variations

PON Design
(inside 32 home PON area)

50

100

150

200

250

300

350

400

100'

200'

400'

SplicedDouble
SplicedQuad

Direct- Mid
Split
Spliced

Direct Feed

Conventional

Conclusion:
Conventional Design is the most economical
For all SFR densities

50' Lots

PON Cabling based on lot size

Single Family Residential Areas- Urban/Suburban

$/SUBSCRIBER

11

13
14
15
16
17
18
19
20
21
22
23
24

12

10

ORANGE

BLUE

Distributed Splitting

Distribution Design Technique-

Housing Density:

Least Dense:
Rural Areas

1x16
1x2

1x8
1x4

1x4
1x8

1x32

1x2

1x4

1x8

1x2

1x4

1x2

12 fiber

1x4

12 fiber

1x8

12 fiber

1x32

24 fiber

1x2

1x4

1x2

1x4

1x8

Optical Splitter Options

1x2

1x4

1x2

1x4

5000

6000

7000

0 0

1000

2000

3000

4000

TO TAL CO S T

3
5
7
9
PON DISTANCE IN KFT

11

When to distribute splitters

1X4/1
X8
SPLI
TTER

1X32
SPLI
TTER

8
8

8
8

Distributed Splitting Technique

Rural Area

LOW

100

HOUSING DENSITY

HIGH

90

80

70

60

50

TAKE RATE

EACH PON

SPLITTERS IN

40

30

CO
20

10

SPLITTERS IN

CABINETS

SPLITTERS IN

RURAL AREA
8 KFT
6
4
2
0

Economical Splitter Location

DISTANCE FROM HEADEND

PON cable design

PON Design
(inside 32 home PON area)

2. Use 2 fiber drop to have a spare fiber


available

1. Design for about 8 drops per closure

Fiber Drop Design:

4. Plan approval up front streamlines approval process

3. Proper cable sizing for the entire network

build dates

2. Manage budgets over the years to meet targeted

all the pieces fit together in the end

1. Have a long range plan to follow to make sure

Lessens Learned:

Fundamental Planning and Design

1 Fiber to each
unit in towm
fromCOor node

Splitters in
COor node

Vertical quick
connect design

HIgh Rise

No

PON < 5000'

SIngle Family

Connectorized
Drop
Design

Labor Rate <$75

Conventional
Design
Fusion Splice Drops

Yes

Yes

1x32 Distributed
Splitting

Optional
Inside Small Towns

loop cable
Distribute
Splitters

Campus Style

Multi-Dwelling

Housing Density

Conventional
Design
Fusion Splice Drops

1x4/8 Distributed
Splitting

No

Yes

No

Vertical quick
connect design

HIgh Rise

>50%

Take Rate

Yes

Yes

Labor Rate< $75

1x32 Splitters
in 256home
cabinets

1 Fiber to each
unit from
cabinet or node

Splitters in
cabinet or
onsite node

Campus Style

Conventional
Design
Fusion Splice Drops

Multi-Dwelling

Yes

No

PON < 5000'

SIngle Family

Connectorized
Drop
Design

1 Fiber to each
unit from
COor node

Splittersin
COor node

Customers >
4000' fromCO
or node

No

Housing Density

Conventional
Design
Fusion Splice Drops

1x4/8 Distributed
Splitting

No

Flow Chart

Design Decision

FTTH ACTUAL
EXAMPLES

32

19

64
13 0 0'
2 4 fib er

SS

31

S
35 0'
1 2 fib er

32
27 00 '
2 4 fib er

22 00 '
2 4 fib er

32
S

14 00 '
3 6 fib er

30 0'
2 4 fib er

60 0'
2 4 fib er

45 0 '
1 2 fib er

32 00 '
3 6 fib er

90 0'
3 6 fib er
12 0'
er
1 2 fib

16

15 50 '
3 6 fib er

17 00 '
2 4 fib er

32

30 0'
er
1 2 fib

1 50 0'
3 6 fib er

29

To Headend/CO

12 50 '
2 4 fib er

64
32

13 00 '
er
3 6 fib
60 0'
1 2 fib er

12 00 '
3 6 fib er

S
19

SS

S
S

3S2

64

65 0'
1 2 fib er

17 5'
er
1 2 fib
70 0 '
er
2 4 fib

90 0'
1 2 fib er

3 1S
17 50 '
2 4 fib er

12 00 '
er
2 4 fib
11 00 '
3 6 fib er

32

15 00 '
er
2 4 fib

15 50 '
er
2 4 fib

10 00 '
2 4 fib er

70 0'
1 2 fib er
23 50 '
2 4 fib er

32

12

2S7

Amount
4245
20100
12150

18

126

83000

Fiber Cable:
Size
12 FIBER
24 FIBER
36 FIBER

1x32 Optical Splitter

CLOSURES

Fiber Drop

AT-3BE8T7X-002

300524378

Order Code
AT-3BE12YT-012
AT-3BE12YT-024
AT-3BE12YT-036

0.284
0.35

SINGLE JACKET-DCM_12F A W _.35/.25@1310/1550


SINGLE JACKET-DCM_24F A W _.35/.25@1310/1550
SINGLE JACKET-DCM_36F A W _.35/.25@1310/1550

Grand Total:
Cost per home passed including drop:

2 Fiber flat drop

Cost per home passed:

TYCO 450A OR EQUIVALENT

0.14

$42,340

total

$53,960
$98.29

$11,620

$77

18900

12600

Cost
$879
$5,708
$4,253

150

700

0.207

Description

R1-1X32-FULL-UNC-00-BAL

Planning
Price

1800'
24 FIBER
CABLE

32

24
FIBER
CABLE

32

2300'
24 FIBER
CABLE

32

32

32

32

36 FIBER
CABLE

900'
24 FIBER
CABLE

1200'
24 FIBER
CABLE

275'
12 FIBER
CABLE

32

32
32

32

250'
12 FIBER
CABLE

36 FIBER
CABLE

95'
12 FIBER
CABLE

2500'
36 FIBE
CABLE

30

32

36 FIB
CABL

650'
12 FIBER
CABLE

2750'
24
FIBER
CABLE

36 FIBER
CABLE

2000'
24 FIBER
CABLE

3100'
36 FIBER
CABLE

AMOUNT
2170
10476
7100
2600

11

73

12 FIBER
24 FIBER
36 FIBER
144 FIBER

32 SPLITTER

CLOSURES

300524378

Part#
AT-3BEH2YT-012
AT-3BEH2YT-024
AT-3BEH2YT-036
AT-3BEH2YT-144

323 living units

TYCO 450A OR EQUIVALENT


PRICES ARE

3,124
3,380

0.44
1.3

$29,704

total

FOR PLANNING
PURPOSES ONLY

10,950

7,425

3,981

0.38

675

694

0.32

cost

150

$/unit

Cost per home passed = $92

Ruggedized 1x32 optical splitter

Description
LIGHT ARMOR_12F A W _.35/.25@1310/1550
LIGHT ARMOR_24F A W _.35/.25@1310/1550
LIGHT ARMOR_36F A W _.35/.25@1310/1550
LIGHT ARMOR_144F A W _.35/.25@1310/1550

100

1x32 splitter

CLOSURES

Note: Drop calculated at 100' per living unit

300524378

Part#
AT-3BE12YT-012
AT-3BE12YT-024
AT-3BE12YT-036
AT-3BEH2YT-048

73800 AT-3BE8T7X-002

24

12 FIBER
24 FIBER
36 FIBER
48 FIBER

FIBER DROP

AMOUNT
1800
13400
5500
1200

564

0.47

$35,599

total

0.14

$62

$10,332

$48

FOR
PLANNING
PURPOSES ONLY

12,500

125

Cost per home passed =

PRICES ARE

2,035

0.37

16,200

3,886

0.29

675

414

cost
0.23

$/unit

Total Cost Per Home Passed =

Mini LT 2 fiber Flat drop cable

TYCO 450A OR EQUIVALENT

Ruggedized 1x32 optical splitter

Description
SINGLE JACKET-DCM_12F A W _.35/.25@1310/1550
SINGLE JACKET-DCM_24F A W _.35/.25@1310/1550
SINGLE JACKET-DCM_36F A W _.35/.25@1310/1550
SINGLE JACKET-DCM_48F A W _.35/.25@1310/1550

738 living units

PROPERTY OF BUCKEYE CABLEVISION INC.


DO NOT DISTRIBUTE OR DUPLICATE

Per home
passed =
$146

Per home
passed =
$86

CONFIDENTIAL
AND PROPRIETARY

Material
cost

Material
cost

CONFIDENTIAL
AND PROPRIETARY
PROPERTY OF BUCKE YE CABLEVISION INC.
DO NOT DISTRIBUTE OR DUPLICATE

14700

48

AT-3BE8T7X-002

(meters)
AMOUNT
50
2480
1700
900
Part#
AT-3BE12YT-012
AT-3BEH2YT-036
AT-3BEH2YT-072
AT-3BEH2YT-192

14700

48

AT-3BE8T7X-002

(DISTANCE CALCULATED AT 60m PER HOME PASSED)

FIBER DROP

CLOSURES

$30,387

0.47

Cost per home passed =

$152

$6,909

$124

FOR
PLANNING
PURPOSES ONLY

total

4,800

6,000

5,600
150

125

6,000

3,537

3.9300

700

2,635

1.5500

6000

30
1,786

0.7200

cost

$90

$6,909

$61

0.5900

$/unit

$/mtr)

Total Cost Per Home Passed =

Mini LT 2 fiber Flat drop cable

TYCO 450A OR EQUIVALENT


PRICES ARE

Description
SINGLE JACKET-DCM_12F A W _.35/.25@1310/1550
SINGLE JACKET-DCM_36F A W _.35/.25@1310/1550
SINGLE JACKET-DCM_72F A W _.35/.25@1310/1550
SINGLE JACKET-DCM_192F A W _.35/.25@1310/1550

Note: when comparing costs, add splicing cost for 84 additional splices

288 Orbital Cabinet


1
300530565
Orbital288-SCA-01-06-12YT-2/144-100F
1x32 splitter
8
300505856
S1-1X32-FULL-MPO/SCA-S-BAL-F
MPO Jumpers
32
300543022
MPO8UAPC/SCAPC-LL/TCF-HZ001-0.78M
Note: r/w cost, conctrete pad and conduit cost not included in this amount for cabinet

12 FIBER
36 FIBER
72 FIBER
192 FIBER

SPLITTER CABINET
PLAN

0.47

Total Cost Per Home Passed =

Mini LT 2 fiber Flat drop cable

$15,037

total

FOR
PLANNING
PURPOSES ONLY

6,000

125

5,200

30
3,658

0.7200
650

cost

$/unit
0.5900

$/mtr)

Cost per home passed =

PRICES ARE

R1-1X32-FULL-UNC-00-BAL

300524378

TYCO 450A OR EQUIVALENT

Description
SINGLE JACKET-DCM_12F A W _.35/.25@1310/1550
SINGLE JACKET-DCM_24F A W _.35/.25@1310/1550

245 living units

Part#
AT-3BE12YT-012
AT-3BE12YT-024

(DISTANCE CALCULATED AT 60m PER HOME PASSED)

FIBER DROP

CLOSURES

DISTRIBUTED SPLITTING
PLAN
(meters)
AMOUNT
12 FIBER
50
24 FIBER
5080
5130
1x32 splitter
8

ALCALU TRIAL

26

1x32 splitter

CLOSURES

300524378

LPS1-A-SCAUNC-BR-072-07-50F
Allwave Advantage MW1LC-SC-20

Part#
AT-3BE8T7X-012
AT-3BE12YT-036
AT-3BE12YT-060
AT-3BE12YT-072

Note: 300' per home passed assumed for drop length

29700 AT-3BE8T7X-002

2
99

Fiber Shelves
Fiber jumpers

FIBER DROP

AMOUNT
15400
9100
17000
12700

12 FIBER
36 FIBER
60 FIBER
72 FIBER

Home Run from Remote

Hancock Tel

Note: 300' per home passed assumed for drop length

29700 AT-3BE8T7X-002

26

CLOSURES

FIBER DROP

4
14

AMOUNT
Part#
54200
AT-3BE8T7X-012

1x4 splitter
1x8 splitter

12 FIBER (Mini LT)

$6,850

total

0.14

PRICES ARE

$25,420

total

FOR
PLANNING
PURPOSES ONLY

2,600

100

2,800

1,485
700

3,000
15

0.48
1500

6,800
6,096

0.4

0.14

Total Cost Per Home Passed =

Mini LT 2 fiber Flat drop cable

$299

$4,158

Cost per home passed = $257

TYCO 450A OR EQUIVALENT

Ruggedized 1x32 optical splitter

72 port termination shelf


Fiber jumpers from splitter to shelf

2,639

0.29

cost
3,234

0.21

$/unit

$111

$4,158

$69

FOR
PLANNING
PURPOSES ONLY

2,600

100

600
3,500

250

Total Cost Per Home Passed =

Mini LT 2 fiber Flat drop cable

Description
Mini LT 12 fiber Flat drop cable
SINGLE JACKET-DCM_36F A W _.35/.25@1310/1550
SINGLE JACKET-DCM_60F A W _.35/.25@1310/1550
SINGLE JACKET-DCM_72F A W _.35/.25@1310/1550

99 living units

PRICES ARE

cost
11,382

150

0.21

$/unit

Cost per home passed =

Coyote In-Line Runt or equivalent

1x4 optical splitter


1x8 optical splitter

Description
Mini LT 12 fiber Flat drop cable

Design tips to save


splicing time

IDEAL FEEDER DESIGN

CO OR
HE

CO OR
HE

96

96
96

72
X

X
96

60
X
48

40
WORKING

96

72
X

48
X 96

48

SIZE CABLE TO REDUCE SPLICING

ELIMINATE UNECONOMICAL TAPERS

FIBER CABLE TAPERING

30 WORKING

24

How much bandwidth will


be needed in the future?

Full Spectrum Enabled: Zero Water Peak

Options

15
16

1
2
3
4
5
6
7
8
9
10
11
12
13
14
RF
1591
1611

1471
1491
1511
1531
1550
1571

1411
1431
1451

1271
1291
1311
1331
1351
1371
1391

O1
O2
O3
O4
O5
E1
E2
E3
E4
E5
S1
S2
S3
C1
C2
L1
L2
L3

20 nm spacing between wavelengths

18 wavelengths

ITU G.694.2 (1271 1611 nm)

CWDM Full Spectrum Wavelength grid

Wavelength Legend for Upgrade

Full Spectrum-CWDM

Technology Roadmap:

Figures 1 and 2 show SEM micrographs of fiber endfaces. In both cases the cleaved fiber surface was
briefly etched in acid (48% HF for 3 minutes).
SEM micrographs taken by OFS.

Figure 1. High purity synthetic silica fiber


.

No risk of long wavelength hydrogen aging loss


Minimizes degradation of strength and break
frequency

high purity synthetic silica:

Acne like condition shows difference between


pure and clean synthetic quartz vs natural quartz
with its impurities and inclusions.

Figure 2. Cheap natural quartz raw material fiber


clearly shows many pits and imperfections .

Alkali impurities can lead to long wavelength


hydrogen aging loss
Particulate inclusions can lead to degradation
of strength and increased break frequency

Natural Quartz raw material:

Stable Reliable Performance needed for FTTX

FTTH Designer

770-798-2423

dstallworth@ofsoptics.com

David Stallworth

Thank You!

S-ar putea să vă placă și