Sunteți pe pagina 1din 58

IONOS-NMS For

FMX

Training Handbook
AET/TAC/ 8408 July 2011 issue

8408 IONOS-NMS for FMX July 2011 issue

DISCLAIMER
Documents supplied during the training sessions are not contractual.
Descriptions, schematics, diagrams and figures are for illustration only and can be changed
without notice.
For contractual figures, please refer to official documentation.

Page ii

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

SUMMARY
MODULE 1
To be able to configure FMX for IONOS-NMS management

IONOS-NMS Training handbook

Page iii

8408 IONOS-NMS for FMX July 2011 issue

Page iv

IONOS-NMS for FMX Training handbook

IONOS-NMS for
FMX

Module 1.
Goal :
To be able to configure FMX for IONOS-NMS
management
MODULE 1.
1.1. FMX MANAGEMENT
1.1.1. FRAME RELAY
1.1.2. GIE-P / GIE-S
1.2. SNMP
1.2.1. FMX HEADER WITH GIE-S
1.2.2. FMX HEADER WITH GIE-P
1.3. FMX NETWORK CONFIGURATION

IONOS-NMS for FMX Training handbook

1-1
1-3
1-5
1-10
1-11
1-13
1-14
1-18

Page 1-1

8408 IONOS-NMS for FMX July 2011 issue

1.3.1.
1.3.2.
1.3.3.
1.4.
1.5.
1.6.
1.6.1.
1.7.
1.7.1.
1.7.2.
1.7.3.
1.7.4.

PARAMETERS OF CONFIGURATION
PROXY CONFIGURATION (GIE-P)
GIE-S CONFIGURATION
FMX NETWORK EXAMPLE
FMX NETWORK MANAGEMENT WITH IONOS-NMS
EXERCISE : NETWORK OF FMX
CORRECT VERSION
PROCESS
ATLANTIS CARD CONFIGURATION ON PC PROXY
CREATION OF A FMX (GIE-P HEADER) ON IONOS-NMS
GIE-S CARD CONFIGURATION IN HEADER MODE
GIE-S CARD CONFIGURATION IN NON-HEADER MODE

Page 1-2

1-19
1-25
1-28
1-33
1-36
1-41
1-45
1-49
1-49
1-51
1-52
1-53

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.1. FMX management


Slide 2

IONOS-NMS : Operation and management

The LCT provides all operation and monitoring functions


of local or remote FMX :
Set up of shelves, cards, synchronization parameters.
Display of defaults, alarms and performances.
Maintenance operations such as loopbacks and
inventories.

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-3

8408 IONOS-NMS for FMX July 2011 issue

Slide 3

IONOS-NMS : Operation and management


Its possible from a local FMX to manage a remote FMX.
A FMX network is composed of FMX connected together via
management channels ( DLCI):

LCT
(local)

Local connection :
- Direct,
- Via MODEM.

Local FMX

Network
of FMX

Remote FMX

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-4

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.1.1. Frame Relay


Slide 4

IONOS-NMS : Frame Relay

LCT

FMX Header

from 1 to 9
FMX

FMX

FMX

FMX

Up to :
64 FMX and/or SAGEM 2048.
Only 50 FMX when using snmp
LCT (IONOS-NMS).
over a maximum of 10 levels.

FMX
from 1 to 8
FMX

* To reduce bandwidth consumption, management of the remote FMX is performed


via TS0 (7 directions) + 2 x 64kbps TS.
4

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-5

8408 IONOS-NMS for FMX July 2011 issue

Slide 5

IONOS-NMS : Frame Relay

Frame Relay (2Mb/s G704) :


8 Kbps (2 bits of the odd TS0s).
64 Kbps (any IT).
P1/P2 :
64 Kbps V24/V11.
Used to interconnect 2 Frame Relay FMX subnetworks .
DLCI (Data Link Connection Identifier).

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-6

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 6

IONOS-NMS : Frame Relay


FMX 2
Orderwire

(Remote)
GIE-S

COB
CARTE COB

A2S

Frame relay
Function

Network of
FMX

FMX 1
(Local)
Connection :
LCT
(local)

GIE-S
- LOCAL
- VIA MODEM

COB

Frame relay
Function

A2S

Orderwire

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-7

8408 IONOS-NMS for FMX July 2011 issue

Slide 7

IONOS-NMS : Frame Relay

FMX2

FMX1

GIE

COB

DLCI
FR

orderwire

G704

IP-ISO

COB

GIE

LCT

To an other FMX

To the manager
7

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-8

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 8

IONOS-NMS : Management Network

FMX Header :
Between IONOS-NMS and others FMX of the Frame Relay
management network

FMX none Header.

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-9

8408 IONOS-NMS for FMX July 2011 issue

1.1.2. GIE-P / GIE-S


Slide 9

IONOS-NMS : Management Network

The GIE card manages the communication between the FMX


Header and IONOS-NMS :
GIE-P (P4.3B/P4.3C) :
None SNMP card.
Use of a Proxy-FMX to translate the SNMP protocol in
proprietary Sagem-FMX protocol.
GIE-S (P4.4A) :
SNMP card.

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-10

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.2. SNMP
Slide 10

IONOS-NMS based on SNMP


NEs
with
Embedded SNMP agents

IP

Management
station

Structure
Management
Information

describes

Management
Information
Base

10

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-11

8408 IONOS-NMS for FMX July 2011 issue

Slide 11

Simple Network Management Protocol (SNMP)

SNMP Protocol specifies the language


used by agents and management
stations to communicate.
Protocol :

IP
P
AP A
TR TR

GE
SSEETG
TTEATN
AvNSW
aSvra
W=rva
3var=
r5

type asynchronous question/answer.


Connectionless.
over UDP (User Datagram Protocol).

SNMP system handles three kinds of


requests :
GET
SET
TRAP
11

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-12

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.2.1. FMX header with GIE-S


Slide 12

IONOS-NMS : FMX Header with GIE-S

IONOS
NMS

FMX
GROUP
(remote FMX)
FMX
Header
local

G
I
E
S

IP

FMX
GROUP
(remote FMX)
FMX
Header
local

G
I
E
S

J129 connector with


RJ45 adaptation.
Ethernet

1 GIE-S in each FMX Header, other version (GIE-P) possible in others FMX.
12

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-13

8408 IONOS-NMS for FMX July 2011 issue

1.2.2. FMX header with GIE-P


Slide 13

IONOS-NMS : FMX Header with GIE-P

TRAP
SW
P
N
T
ERATA
SGTE
T
SE
G

IP

PROXY
iso-IP

))(%&
@H(&$*
@
#&@^*!^&#9
#$ #&&*

^& #$$
89

13

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-14

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 14

IONOS-NMS : FMX Header with GIE-P

Management by IONOS-NMS using an external proxy.


A proxy can manage 50 FMX.
FMX Header : 1 for 20 FMX.
The FMX Header has to be configured in mode Gateway.
FMX none Headers part of the Group are configured none gateway.
IONOS
NMS
PROXY

FMX Group

PROXY

FMX
Header

G
I
E
P

IP

X25
J129

PC
PROXY

Eth

14

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-15

8408 IONOS-NMS for FMX July 2011 issue

Slide 15

IONOS-NMS : Example physical presentation

G704

PROXY

X.25

G704

15

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-16

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 16

IONOS-NMS : Example logical presentation

DLCI 1

PROXY
DLCI 2

X.25
DLCI 3
DLCI 4

16

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-17

8408 IONOS-NMS for FMX July 2011 issue

1.3. FMX network configuration


Slide 17

IONOS-NMS

FMX network configuration :

17

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-18

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.3.1. Parameters of configuration


Slide 18

IONOS-NMS : FMX network configuration

Parameters of configuration :
FMX :
An IP/ISO address for each FMX (6 bytes, decimal value < 256 separated by a .).
An interface type for each FMX (with the neighbour FMX) : P1, P2 or Frame Relay.
An identifier (DLCI) for each Frame Relay communication between two FMX
IP/ISO Addresses :
The setting of a frame relay network management for FMX equipment using the
embedded channels of TS0 in the 2 Mbps links requires to take precautions with
the IPiso adress on the FMX equipment as follows :
In every FMX of a given frame relay management subnetwork, including the header FMX and
those connected via PI/P2 interfaces, The first element of the IPiso address (Network ID) must
be UNIQUE.
If there is a mix of P4.4a (GIE-S) FMX equipment and P4.3c (GIE-P) in the subnetwork, the
second element of the IPiso adress (Depth) must be ZERO.
18

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-19

8408 IONOS-NMS for FMX July 2011 issue

Slide 19

IONOS-NMS : FMX network configuration

Parameters of configuration :
FMX Header :
FMX with GIE-P card :
An IPv4 address for the Proxy used by the header.
X25 parameters (address, clock, DCE/DTE) of the link with the Proxy.
FMX with GIE-S card :
An IPv4 address for the header
Ethernet parameters (IP address, mask, default gateway, physical
configuration)
Managers IP addresses

19

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-20

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 20

IONOS-NMS : FMX network configuration

Header using the GIE-P card (P4.3B or P4.3C) :


2 steps :
FMX configuration :
Declaration of IP/ISO addresses and interfaces (FR, P1/P2).
Creation of Frame Relay connections.
Configuration of Gateways (X25, P1/P2).
Proxy configuration :
Reading of the current configuration (Load Command).
Modification of the configuration (Modify and Build).
Loading of the configuration in the Proxy (Send).
20

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-21

8408 IONOS-NMS for FMX July 2011 issue

Slide 21

IONOS-NMS : FMX network configuration


Management network equipments (GIE-P) :

21

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-22

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 22

IONOS-NMS : FMX network configuration


Frame Relay connections (GIE-P) :

22

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-23

8408 IONOS-NMS for FMX July 2011 issue

Slide 23

IONOS-NMS : FMX network configuration


FMX Header configuration (GIE-P) :

23

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-24

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.3.2. Proxy configuration (GIE-P)


Slide 24

IONOS-NMS : FMX network configuration


Proxy configuration (GIE-P) :

24

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Slide 25
IONOS-NMS for FMX Training handbook

Page 1-25

8408 IONOS-NMS for FMX July 2011 issue

IONOS-NMS : FMX network configuration


Proxy configuration (GIE-P) :

25

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-26

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 26

IONOS-NMS : FMX network configuration


Proxy configuration (GIE-P) :

26

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-27

8408 IONOS-NMS for FMX July 2011 issue

1.3.3. GIE-S Configuration


Slide 27

IONOS-NMS : FMX network configuration

Header using the GIE-S card (P4.4A) :


FMX configuration :
Declaration of IP/ISO addresses, interfaces (FR, P1/P2) and
identification number ( ID FMX ).
Creation of Frame Relay connections.
Configuration of IPv4 addresses ( Ethernet port, managers list ).

27

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-28

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 28

IONOS-NMS : FMX network configuration


Management network equipments (GIE-S) :

28

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-29

8408 IONOS-NMS for FMX July 2011 issue

Slide 29

IONOS-NMS : FMX network configuration


Frame Relay connections (GIE-S) :

29

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-30

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 30

IONOS-NMS : FMX network configuration


Ethernet port and/or P1/P2 (GIE-S) :

30

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-31

8408 IONOS-NMS for FMX July 2011 issue

Slide 31

IONOS-NMS : FMX network configuration


Managers IP addresses (GIE-S) :

31

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-32

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.4. FMX network example


Slide 32

IONOS-NMS : FMX network example (GIE-S)


IONOS NMS

Ethernet

IPv4 = 192.168.0.1
IPv4 = 192.168.0.172
P2

P1

2
IP iso = 1.0.2.0.0.0

IP iso = 1.0.1.0.0.0
FR

FR

FR

3
IP iso = 1.0.3.0.0.0

4
IP iso = 1.0.4.0.0.0

5
IP iso = 1.0.5.0.0.0
32

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-33

8408 IONOS-NMS for FMX July 2011 issue

Slide 33

IONOS-NMS : FMX network example (GIE-S)


Equipment table 1 :
IP iso
1.0.1.0.0.0
1.0.2.0.0.0
1.0.4.0.0.0
1.0.5.0.0.0
1.0.3.0.0.0
255.0.0.0.0.0

interface
P2 next
P2
P2
FR
FR

ID
1
2
4
5
3
0

Name
FMX 1
FMX 2
FMX 4
FMX 5
FMX 3
Manager

ID
0
0
0
0
0

Name
FMX 2
FMX 1
Manager
FMX 4
FMX 5

NB : 255.0.0.0.0.0 Type :other = Manager

ROLE : HEADER
TMN - P2 codirectional

Equipment table 2 :
IP iso
1.0.2.0.0.0
1.0.1.0.0.0
255.0.0.0.0.0
1.0.4.0.0.0
1.0.5.0.0.0

interface
P1 next
P1
FR
FR

P1 codirectional - P2 codirectional
33

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-34

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 34

IONOS-NMS : FMX network example (GIE-S)


Equipment table 3 :
IP iso

interface ID

1.0.3.0.0.0

Name

FMX 3

1.0.1.0.0.0

FR

FMX 1

255.0.0.0.0.0

FR

Manager

P1 codirectional - P2 codirectional
Equipment table 4 :
1.0.4.0.0.0
1.0.2.0.0.0

FR

FMX 4

FMX 2

1.0.1.0.0.0

FR

FMX 1

255.0.0.0.0.0

FR

Manager

All equipments 1, 2, 3, 4 and 5 are Gateway

P1 codirectional - P2 codirectional
Equipment table 5 :
1.0.5.0.0.0

FMX 5

1.0.4.0.0.0

FR

FMX 4

1.0.2.0.0.0

FR

FMX 2

1.0.1.0.0.0

FR

FMX 1

255.0.0.0.0.0

FR

Manager

Caution :
In case of PC Proxy (with GIE-P)
equipments 3-4-5 are None gateway.

P1 codirectional - P2 codirectional
34

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-35

8408 IONOS-NMS for FMX July 2011 issue

1.5. FMX network management with IONOSNMS


Slide 35

IONOS-NMS

FMX network management with IONOS-NMS :

35

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-36

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 36

IONOS-NMS

IONOS-NMS manages on FMX equipments only :


FMX configuration/operation.
Alarms management.
2Mbps links between FMX are not managed in IONOS-NMS.
They can be created in the network topology view.
Its only a graphic and static view of the link (no specific alarm
for the link).

36

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-37

8408 IONOS-NMS for FMX July 2011 issue

Slide 37

IONOS-NMS : FMX network configuration

Create subnetworks.
Create a network element (FMX).
Create links between FMX.

37

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-38

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 38

IONOS-NMS : FMX network exploitation


FMX configuration and exploitation (card, ports, connections,) with the LCT :

38

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-39

8408 IONOS-NMS for FMX July 2011 issue

Slide 39

IONOS-NMS : management of Alarms

Alarms log :

Current alarms
39

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-40

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.6. Exercise : Network of FMX


Slide 40

Exercise : Network of FMX


Address plan of FMX with GIE.S :
FMX 1

A2 S

A2 S
1

FMX 3

Header

DLCI 1
DLCI 2
DLCI 3
GIE.S
IP iso : 1.0.1.0.0.0

Slot
14

Slot
12

A2 S

A2 S
Slot
11

FMX 2

1
GIE.S
IP iso : 1.0.2.0.0.0

Slot
13

PC Server
GIE.S
IP Add : 192.168.0.1/16
IP iso : 1.0. 3.0.0.0

Eth.

192.168.0.140
255.255.0.0

FMX 4

1
GIE.S
IP iso : 1.0.4.0.0.0

40

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-41

8408 IONOS-NMS for FMX July 2011 issue

Slide 41

Exercise : Network of FMX


Management network equipment :
Table FMX 1 :
IP iso

interface

ID

Name

Table FMX 2 :
IP iso

interface

ID

Name

Table FMX 3 :
IP iso

interface

ID

Name

Table FMX 4 :
IP iso

interface

ID

Name

41

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-42

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 42

Exercise : Network of FMX


FR frames relay connections :
FMX 1 :

DLCI

Source

Destination

FMX 2 :

DLCI

Source

Destination

FMX 3 :

DLCI

Source

Destination

FMX 4 :

DLCI

Source

Destination

42

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-43

8408 IONOS-NMS for FMX July 2011 issue

Slide 43

Exercise : Network of FMX


IP link and P1/P2 link configuration :

Configuration of the FMX Header (FMX 3) :


IP link and P1-P2 link configuration of FMX 3 :

Choose :
IP v4 address :
Subnetwork Mask :
Default gateway :

RGT/P2 contra or codirectional

Manager Addresses :
For the FMX Header :

43

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-44

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.6.1. Correct version


Slide 44

Correct version : Network of FMX


Address plan of FMX with GIE.S :
A2 S

FMX 1

A2 S
1

FMX 3

Header

DLCI 1
DLCI 1

DLCI 2

DLCI 2
DLCI 3
GIE.S
IP iso : 1.0.1.0.0.0

Slot
14

Slot
12

A2 S

A2 S
Slot
11

FMX 2

Eth.

192.168.0.140
255.255.0.0

FMX 4

DLCI 3

DLCI 2

GIE.S
IP iso : 1.0.2.0.0.0

PC Server
GIE.S
IP Add : 192.168.0.1/16
IP iso : 1.0. 3.0.0.0

Slot
13

1
GIE.S
IP iso : 1.0.4.0.0.0

44

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-45

8408 IONOS-NMS for FMX July 2011 issue

Slide 45

Correct version : Network of FMX


Management network equipment :
Table FMX 1 :
IP iso
1.0.1.0.0.0
1.0.3.0.0.0
255.0.0.0.0.0
Table FMX 2 :
IP iso
1.0.2.0.0.0
1.0.3.0.0.0
255.0.0.0.0.0
Table FMX 3 :
IP iso
1.0.1.0.0.0
1.0.2.0.0.0
1.0.3.0.0.0
1.0.4.0.0.0
255.0.0.0.0.0
Table FMX 4 :
IP iso
1.0.4.0.0.0
1.0.3.0.0.0
255.0.0.0.0.0

interface
FR
FR

interface
FR
FR
interface
FR
FR
FR
FR
interface
FR
FR

ID
0
0
0

Name
FMX 1
FMX 3
Manager

ID
0
0
0

Name
FMX 2
FMX 3
Manager

ID
1
2
3
4
0

Name
FMX 1
FMX 2
FMX 3
FMX
Manager

ID
0
0
0

Name
FMX 4
FMX 3
Manager
45

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-46

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

Slide 46

Correct version : Network of FMX


FR frames relay connections :
FMX 1 :

FMX 2 :

FMX 3 :

FMX 4 :

DLCI

Source

Destination

GIE (64Kbits/s)
1.0.1.0.0.0

A2S ; Slot14 ; port 1; bits 7 and 8 (8Kbps)


1.0.3.0.0.0

A2S ; Slot14 ; port 1; bits 7 and 8 (8Kbps)


1.0.3.0.0.0

A2S ; Slot14 ; port 2; bits 7 and 8 (8Kbps)


1.0.2.0.0.0

DLCI

Source

Destination

GIE (64Kbits/s)
1.0.2.0.0.0

A2S ; Slot13 ; port 1; bits 7 and 8 (8Kbps)


1.0.3.0.0.0

DLCI

Source

Destination

GIE (64Kbits/s)
1.0.3.0.0.0

A2S ; Slot12 ; port 1; bits 7 and 8 (8Kbps)


1.0.1.0.0.0

GIE (64Kbits/s)
1.0.3.0.0.0

A2S ; Slot12 ; port 1; bits 7 and 8 (8Kbps)


1.0.2.0.0.0

GIE (64Kbits/s)
1.0.3.0.0.0

A2S ; Slot12 ; port 2; bits 7 and 8 (8Kbps)


1.0.4.0.0.0

DLCI

Source

Destination

GIE (64Kbits/s)
1.0.4.0.0.0

A2S ; Slot11 ; port 1; bits 7 and 8 (8Kbps)


1.0.3.0.0.0
46

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

IONOS-NMS for FMX Training handbook

Page 1-47

8408 IONOS-NMS for FMX July 2011 issue

Slide 47

Correct version : Network of FMX


IP link and P1/P2 link configuration :

Configuration of the FMX Header (FMX 3) :


IP link and P1-P2 link configuration of FMX 3 :

Choose :
IP v4 address :
Subnetwork Mask :
Default gateway :

Manager Addresses :
For the FMX Header :

RGT/P2 contra or codirectional


192.168.0.1
255.255.0.0
192.168.0.140 (router @).

192.168.0.140

47

| AET/TAC 8408 | July 2011

______________________________________________________________________________________________
___________________________________________________________________________________________

Page 1-48

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.7. Process
1.7.1. ATLANTIS card configuration on PC Proxy
Access path to ATLANTIS card parameters :
Start > Settings > Control Panel
Double click on Network Connections icon > Service > ATLANTIS- Header X25/ISDN (Prima
P2) > Properties.

Click on

VOIE A &

Then on

Inside the tools bar.

Type of data circuit

DB25

Type of protocol

X25

Type of Network

Transpac-(FR)

Type of behaviour

TERM / DTE

Recovery block

or DCE

nX25

Disconnections on exit appli

Transmission of nX25

Timer of network disconnection

Reception of nX25

Transmission of NUI

Click on

To see the second window

n of assigned VL

Flow ctrl parameters

Number of CVP

Transmitted block window

Number of incoming VL

Received block window

n of low mixed VL

Transmitted block size

256

n of high mixed VL

128

Received block size

256

n of low outgoing VL
n of high outgoing VL

IONOS-NMS for FMX Training handbook

Page 1-49

8408 IONOS-NMS for FMX July 2011 issue

Click on

Link layer:

Physical layer:

K Frame window

N2 meter

10

T1 Temporisation

20

Clock

External

x If DTE

Internal

If DCE

Speed rate

64000

Disc before SABM

Line interface

V24/V28

Transmission of XID

Management command
Management signal DTR
Waiting tempo DSR

Management signal RI

Page 1-50

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.7.2. Creation of a FMX (GIE-P Header) on IONOSNMS


I Creation of NE on IONOS-NMS :
- Open NMS Client.
- Create a NE.
- Type : FMX P4.3C.
- Give a name.
- Give a Equipment number ( has to be unique ).
- Give the PC Proxy IP address.
- Tick the under Proxy box.
- Create 2Mbps interface ( virtual, only for style of drawing ).
II PC Proxy configuration :
1.

Launch Proxy Configuration from a PC Client.

2.

Verify FTP PROFILE


- Click on A then on Modify .
- Give the PC Proxy address.
- Give User, password and port of the PC Proxy ( ex : administrator ; SaGeM ; 21 ).

3.

Make a Load to load all information from the PC Proxy to the PC client.
(systematic if we dont want to run over the Proxy configuration)

4.

Verify the Configuration


-

Proxy : X25@ = 00141


Manager : IP@ of PC server;
ex : 192.168.0.140
BMX : Configuration of FMX; Make ADD to add one FMX.
ID : Has to correspond to the equipment number of FMX given at the creation of
the NE on IONOS-NMS.
- Name : name of the FMX.
- @X25 : X25 address of the FMX in gateway mode; ex : 00541
- @IP : IPiso address of the FMX; ex : 1.0.0.0.0.1

5.

If we did some modifications ( ex : add FMX )


Make a Built ( we have to be in FTP Profile to turn accessible Built, Load
and Send keys).
Then make a Send :
 Tick the Proxy Reboot box ( modifications will take in count only after a
reboot of the PC Proxy )
 Send
IONOS-NMS for FMX Training handbook

Page 1-51

8408 IONOS-NMS for FMX July 2011 issue

1.7.3. GIE-S card configuration in header mode


1- Menu Configuration / general parameters select Gateway
2- Menu management network / TMN link and P1-P2 link configuration
Select TMN/P2
Give the IP address of the FMX Ethernet port ( J129 ) mask and gateway.
3- Menu management network / Manage network Equipment :
4- Change the FMX address ( by default 1.0.0.0.0.0 )
5- Give a FMX ID ( It will be the same one used when creating the NE on IONOS )
6- Add all FMX reachable by this equipment ( address + ID + (type = FMX )+ name
+ (interface = Frame relay or P2 ))
7- Add NMS ( type other ; ID = 0 ; @ IPv6= 255.0.0.0.0.0 and a name)
8- Menu Management network / Managers Address
Add all NMS IP addresses managing this equipment.
9-

Menu Management network / Frame relay connections


Add all frame relay connection
A- Give a name and a DLCI number ( 1 to 1024 )
B- Give IP iso addresses for source and destination entities
C- Select a rate ( 8kbits/s = 2 bits of TS0; 64 kbits/s = GIE or TS different of
TS0 )
D- Select source and destination entities ( GIE is always already relayed )
In any case GIE will be always selected as a source.

Page 1-52

IONOS-NMS for FMX Training handbook

8408 IONOS-NMS for FMX July 2011 issue

1.7.4. GIE-S card configuration in non-header mode


1- Menu Configuration / general parameters select Gateway
2- Menu management network / TMN link and P1-P2 link configuration
Select P1/P2 (ex: P1 co-directional /P2 co-directional )
3- Menu management network / Manage network Equipment :
4- Change the FMX address ( by default 1.0.0.0.0.0 )
5- Give a FMX ID = 0
6- Add all FMX reachable by this equipment ( address + ID=0 + type = FMX + name
+ interface = Frame relay or P1 or P2 )
7- Add NMS ( type other ; ID = 0 ; @ IPv6= 255.0.0.0.0.0 and a name)
8- Menu Management network / Managers Address
No need to put NMS address ( done by the header ).
9- Menu Management network / Frame relay connections
A- Add all frame relay connection
B- Give a name and a DLCI number ( 1 to 1024 )
C- Give IP iso addresses for source and destination entities
D- Select a rate ( 8kbits/s = 2 bits of TS0; 64 kbits/s = GIE or TS different of TS0 )
for source and destination
E- Select source and destination entities ( GIE is always already relayed )
In any case GIE will be always selected as a source.

IONOS-NMS for FMX Training handbook

Page 1-53

8408 IONOS-NMS for FMX July 2011 issue

Page 1-54

IONOS-NMS for FMX Training handbook