VSL

Strand Properties
Strand Type

13 mm (0.5'')

15 mm (0.6'')

Strand Type
N
S
Nominal diameter mm
12.5
12.9
Nominal area
mm 2
93
100
Tensile strength
MPa
1,860
1,860
Min. breaking load
kN
173
186
195 approx.
Young's modulus
GPa
max 2.5
Relaxation
%
The above values are indicative, and the regional standards must be applied.

N
15.2
140
1,860
260

S
15.7
150
1,860
279

Tendon Properties
Strands Type 0.5''

Number
of strands
per
tendon
u
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55

Strands Type 0.5'' N


1,860 MPa

Strands Type 0.6''

Strands Type 0.5'' S


1,860 MPa

Area of
the tendon
mm2

Minimum
breaking load
kN

Area of
the tendon
mm2

Minimum
breaking load
kN

93
186
279
372
465
558
651
744
837
930
1,023
1,116
1,209
1,302
1,395
1,488
1,581
1,674
1,767
1,860
1,953
2,046
2,139
2,232
2,325
2,418
2,511
2,604
2,697
2,790
2,883
2,976
3,069
3,162
3,255
3,348
3,441
3,534
3,627
3,720
3,813
3,906
3,999
4,092
4,185
4,278
4,371
4,464
4,557
4,650
4,743
4,836
4,929
5,022
5,115

173
346
519
692
865
1,038
1,211
1,384
1,557
1,730
1,903
2,076
2,249
2,422
2,595
2,768
2,941
3,114
3,287
3,460
3,633
3,806
3,979
4,152
4,325
4,498
4,671
4,844
5,017
5,190
5,363
5,536
5,709
5,882
6,055
6,228
6,401
6,574
6,747
6,920
7,093
7,266
7,439
7,612
7,785
7,958
8,131
8,304
8,477
8,650
8,823
8,996
9,169
9,342
9,515

100
200
300
400
500
600
700
800
900
1,000
1,100
1,200
1,300
1,400
1,500
1,600
1,700
1,800
1,900
2,000
2,100
2,200
2,300
2,400
2,500
2,600
2,700
2,800
2,900
3,000
3,100
3,200
3,300
3,400
3,500
3,600
3,700
3,800
3,900
4,000
4,100
4,200
4,300
4,400
4,500
4,600
4,700
4,800
4,900
5,000
5,100
5,200
5,300
5,400
5,500

186
372
558
744
930
1,116
1,302
1,488
1,674
1,860
2,046
2,232
2,418
2,604
2,790
2,976
3,162
3,348
3,534
3,720
3,906
4,092
4,278
4,464
4,650
4,836
5,022
5,208
5,394
5,580
5,766
5,952
6,138
6,324
6,510
6,696
6,882
7,068
7,254
7,440
7,626
7,812
7,998
8,184
8,370
8,556
8,742
8,928
9,114
9,300
9,486
9,672
9,858
10,044
10,230

Number
of strands
per
tendon
u
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55

Strands Type 0.6'' N


1,860 MPa
Area of
the tendon
mm2

140
280
420
560
700
840
980
1,120
1,260
1,400
1,540
1,680
1,820
1,960
2,100
2,240
2,380
2,520
2,660
2,800
2,940
3,080
3,220
3,360
3,500
3,640
3,780
3,920
4,060
4,200
4,340
4,480
4,620
4,760
4,900
5,040
5,180
5,320
5,460
5,600
5,740
5,880
6,020
6,160
6,300
6,440
6,580
6,720
6,860
7,000
7,140
7,280
7,420
7,560
7,700

Minimum
breaking load
kN

260
520
780
1,040
1,300
1,560
1,820
2,080
2,340
2,600
2,860
3,120
3,380
3,640
3,900
4,160
4,420
4,680
4,940
5,200
5,460
5,720
5,980
6,240
6,500
6,760
7,020
7,280
7,540
7,800
8,060
8,320
8,580
8,840
9,100
9,360
9,620
9,880
10,140
10,400
10,660
10,920
11,180
11,440
11,700
11,960
12,220
12,480
12,740
13,000
13,260
13,520
13,780
14,040
14,300

Strands Type 0.6'' S


1,860 MPa
Area of
the tendon
mm2

Minimum
breaking load
kN

150
300
450
600
750
900
1,050
1,200
1,350
1,500
1,650
1,800
1,950
2,100
2,250
2,400
2,550
2,700
2,850
3,000
3,150
3,300
3,450
3,600
3,750
3,900
4,050
4,200
4,350
4,500
4,650
4,800
4,950
5,100
5,250
5,400
5,550
5,700
5,850
6,000
6,150
6,300
6,450
6,600
6,750
6,900
7,050
7,200
7,350
7,500
7,650
7,800
7,950
8,100
8,250

279
558
837
1,116
1,395
1,674
1,953
2,232
2,511
2,790
3,069
3,348
3,627
3,906
4,185
4,464
4,743
5,022
5,301
5,580
5,859
6,138
6,417
6,696
6,975
7,254
7,533
7,812
8,091
8,370
8,649
8,928
9,207
9,486
9,765
10,044
10,323
10,602
10,881
11,160
11,439
11,718
11,997
12,276
12,555
12,834
13,113
13,392
13,671
13,950
14,229
14,508
14,787
15,066
15,345

Multistrand Post - Tensioning

VSL

Stressing Anchorage VSL Type CS 2000


C

F1 resp. F2
E

J1 resp J2

K
30
B

Pxt stirrups or equivalent orthogonal reinforcement

X = Anchorage spacing
X r = Clearance to edge

Stressing Anchorage VSL Type CS 2000


Tendon
A
B
C
D
E 1) F1 F2
G
H
J1
J2
K
n
M
O
Unit
6-7
222 60 50 143 50 400 535 250 200
60/67
59/73 14
5
258 80 60 178 55 500 638 290 250
6-12
80/87
76/91 16
6
300 90 62 212 60 540 660 375 350 95/102 100/116 20
6-19
8
6-22
320 100 62 232 30 570 740 410 350 110/117 100/116 20
8
6-31
390 120 69 274 30 650 800 490 440 130/137 130/146 22
9
6-37
420 130 82 300 30 835 985 545 450 140/150 130/146 16
10 665 55
Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cube), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
L1: valid for CS STANDARD, L2 valid for CS PLUS and CS SUPER .
J1: standard inner/outer diameter of corrugated steel duct.
J2: standard inner/outer diameter of PT Plus duct.
n: number of spiral turns.
X: anchorage spacing, minimum clearance to edge Xc = 0.5*X + cover.
1) When diameter G to small to clear "nose" of bearing plate, set spiral back (i.e. E + 30mm).

18

11

300
390
490
530
630
685

Multistrand Post - Tensioning

VSL

Stressing Anchorage VSL Type Ec

Tendon Unit

Dimensions
J
10
10
12
14
16
18
20
22
22
22

n
3
3
4
5
6
6
7
7
8
9

X
145
160
200
270
350
370
440
480
510
550

6-3
135
125
50
95
55
40/45
160
145
6-4
150
155
55
110
65
45/50
200
210
6-7
190
170
60
135
84
60/67
250
260
6-12
250
245
75
170
118
80/87
330
345
6-19
310
305
95
200
150
100/107
400
440
6-22
340
365
100
220
178
110/117
430
480
6-31
390
350
120
260
192
130/137
510
540
6-37
430
450
135
280
215
140/150
550
605
Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
J: diameter of spiral steels.
n: number of spiral turns.
X: according to a0 of the French approval.

10
12
14
16
18
18
22
22

3
4
5
6
7
8
8
9

160
200
250
330
400
430
510
550

A
120
135
165
215
270
290
340
370
395
430

B
130
125
155
215
285
335
365
360
380
460

C
50
50
55
60
75
85
95
105
110
130

D
90
95
110
150
180
190
230
240
260
290

E
50
55
74
104
135
150
172
188
201
230

F
35/40
40/45
50/57
65/72
80/87
85/92
100/107
120/127
130/137
140/150

G
145
160
200
270
350
370
440
480
510
550

S trand
Type 0.6

S trand
Type 0.5

H
145
145
210
285
345
380
440
475
540
605

5-3
5-4
5-7
5-12
5-19
5-22
5-31
5-37
5-42
5-55

Stressing Anchorage VSL Type E

Tendon Unit

Dimensions
K
8
10
10
12
14
16
18
18
20
22
22

n
2.5
3.5
3.5
4.5
5.5
6.5
6.5
7.5
7.5
7.5
8.5

X
80
145
170
230
310
395
430
500
550
590
680

18
60
100
100
30/35
10
50
53
6-1
80
50
175
145
150
40/45
15
50
90
6-2
120
56
165
185
150
45/50
25
50
95
6-3
150
200
50/55
65
165
215
6-4
170
25
55
110
250
60/67
84
155
290
6-7
220
35
60
135
330
80/87
118
325
380
6-12
300
45
75
170
480
420
95/102
55
95
200
150
475
6-19
370
520
420
110/117
60
100
220
172
590
6-22
400
620
520
130/137
75
120
260
192
615
6-31
470
140/150
280
215
750
680
585
520
80
135
6-37
Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
K: diameter of spiral steels.
n: number of spiral turns.
X: according to a0 of the French approval.

8
10
10
12
14
16
18
18
20
22

2.5
3.5
3.5
4.5
5.5
6.5
7.5
7.5
8.5
9.5

100
145
185
215
290
380
480
520
660
680

S trand
Type 0.5

J
25/30
40/45
45/50
55/60
65/72
80/87
85/92
100/107
120/127
130/137
140/150

S trand
Type 0.6

5-1
5-3
5-4
5-7
5-12
5-19
5-22
5-31
5-37
5-42
5-55

A
70
120
140
180
250
300
330
400
420
450
520

B
10
15
20
25
35
45
50
60
65
60
75

C
45
50
50
55
60
75
85
95
105
110
130

D
42
90
95
110
150
180
190
230
240
260
290

E
15
50
55
74
104
135
150
172
188
201
230

F
60
175
170
165
205
355
430
490
505
530
605

G
80
145
170
230
310
395
430
500
550
590
680

H
90
135
150
200
275
330
360
420
455
490
560

Multistrand Post - Tensioning

VSL

Coupler VSL Type K

Coupler VSL Type K


B

S trand
Type 0.5

5-3
5-7
5-12
5-19
5-22
5-31
5-37
5-42
5-55

430
550
650
740
830
1,140
1,320
1,290
1,370

140
140
140
140
140
140
180
180
200

40
60
60
80
90
90
120
130
150

130
170
200
240
260
350
390
395
420

S trand
Type 0.6

Tendon Unit

6-2
6-3
6-4
6-7
6-12
6-19
6-22
6-31
6-37

380
490
520
630
730
860
930
1,090
1,390

150
160
160
160
160
160
160
180
200

30
60
60
70
80
90
90
130
130

140
150
160
190
240
280
310
360
430

Dimensions in mm.
For concrete strength, stressing, and spacing, please refer to anchorages types Ec or E.

Coupler VSL Type V

Coupler VSL Type V


E

Strand
Type 0.5

5-3
5-7
5-12
5-19
5-22
5-31

275
400
420
560
630
940

205
205
205
205
205
205

220
260
320
455
520
600

30
60
60
80
90
90

140
180
210
240
260
350

Strand
Type 0.6

Tendon Unit

6-2
6-3
6-4
6-7
6-12
6-19

160
260
290
400
500
630

215
225
225
225
225
225

200
210
210
220
410
580

30
60
60
70
80
90

150
160
170
200
250
290

Dimensions in mm.

Multistrand Post - Tensioning

VSL

Dead-End Anchorage VSL Type H

Dead-End Anchorage VSL Type H


Tendon Unit
5-3
5-4
5-7

6
Strand
Type 0.5

5-12
5-19
5-22
5-31
5-37
5-42
5-55

Strand
Type 0.6

6-3
6-4
6-7
6-12
6-19
6-22
6-31
6-37

Alternative

Type

1
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
3
1
2
3

I
I
I
II
II
II
I
II
II
II
II
II
II
II
II
II
II
II
II
II
II

230
310
150
370
170
350
310
470
310
570
390
670
470
770
470
870
670
570
1,170
870
570

70
70
170
70
190
190
270
190
390
190
390
310
430
310
550
350
430
550
350
430
670

930
930
930
1,280
1,280
1,280
1,280
1,280
1,280
1,280
1,280
1,480
1,480
1,680
1,680
1,680
1,680
1,680
1,980
1,980
1,980

180
180
200
200
230
230
300
300
350
350
350
350
400
400
400
400
400
400

155
155
155
155
155
155
155
155
155
155
165
165
165
165
165
185
185
185

12
12
14
14
14
14
16
16
16
16
18
18
18
18
18
20
20
20

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1
1
2
1
2
1
2
1
2
1
2
1
2
1
2

I
I
I
II
II
II
I
II
II
II
II
II
II
II
II

290
390
190
450
210
430
390
570
390
690
470
810
570
1,050
690

90
90
210
90
230
230
330
230
470
230
490
260
510
370
510

950
950
950
1,300
1,300
1,300
1,300
1,300
1,300
1,300
1,300
1,700
1,700
2,000
2,000

200
200
230
230
300
300
350
350
400
400
400
400

155
155
155
155
155
155
155
155
165
165
185
185

14
14
14
14
16
16
16
16
18
18
20
20

7
7
7
7
7
7
7
7
7
7
7
7

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
n: number of spiral turns.

Multistrand Post - Tensioning

VSL

Dead-End Anchorage VSL Type P

Dead-End Anchorage VSL Type P

Strand
Type 0.6

Strand
Type 0.5

Tendon Unit

5-1
5-3
5-7
5-12
5-19
5-22
5-31

120
230
230
230
230
230
230

60
70
140
210
350
350
350

300
350
400
500
600
800

130
190
220
260
260
260

100
150
180
180
180

188
262
264
316
316
316

8
12
12
14
16
16

4
4
5
5
5
5

6-1
6-2
6-3
6-4
6-7
6-12
6-19

130
230
230
230
230
230
230

80
60
100
100
185
280
470

250
300
350
400
500
700

130
190
190
220
260
260

100
150
150
150
180
180

188
262
262
264
316
316

8
12
12
14
16
16

4
4
4
5
5
5

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
n: number of spiral turns.

Dead-End Anchorage VSL Type U

Dead-End Anchorage VSL Type U

Strand
Type 0.6

Strand
Type 0.5

Tendon Unit

5-1
5-3
5-7
5-12
5-19
5-22
5-31

15
70
160
280
400
440
640

600
600
600
700
800
900
1,300

78
112
114
126
126
126

130
190
220
260
260
260

188
262
264
316
316
316

8
12
14
16
16
16

4
5
5
5
5
5

6-1
6-2
6-3
6-4
6-7
6-12
6-19

35
75
145
145
255
400
690

600
600
600
600
700
900
1,450

78
112
112
114
126
126

130
190
190
220
260
260

188
262
262
264
316
316

8
12
12
14
16
16

4
5
5
5
5
5

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
n: number of spiral turns.

Multistrand Post - Tensioning

VSL

Intermediate Anchorage VSL Type Z

Intermediate Anchorage VSL Type Z

Strand
Type 0.6

Strand
Type 0.5

Tendon Unit

F 2)

1)

5-2
5-4 1)
5-6
5-12
5-22

130
160
200
280
350

60
70
90
140
170

80
90
130
140
200

60
65
85
90
120

400
500
600
1,000
1,450

560
720
890
1,440
2,070

170
200
240
320
390

6-2 1)
6-4 1)
6-6
6-12
6-22

140
170
210
300
400

70
80
100
160
190

90
100
140
160
250

65
70
90
100
145

450
900
1,000
1,350
1,500

620
1,130
1,320
1,910
2,290

180
210
250
340
440

2)

Dimensions in mm.
1) Tension ring only on side 2.
2) Dependent upon the shape of the concrete surface.
The values stated apply for surfaces which are not curved.

Dead-End Anchorage VSL Type ZU

Intermediate Anchorage VSL Type ZU


Tendon Unit
Strand
Type 0.5''

5-2
5-4
5-6

1)

Strand
Type 0.6''

6-2
6-4
6-6

1)

1)

1)

F 2)

165
165
165

103
103
113

80
88
95

60
65
70

450
600
650

655
835
925

200
200
220

170
170
200

105
105
120

90
92
105

65
65
75

450
560
650

700
815
930

210
220
240

Dimensions in mm.
1) Tension ring only on side 2.
2) Dependent upon the shape of the concrete surface.
The values stated apply for surfaces which are not curved.

2)

Multistrand Post - Tensioning

VSL

Dead-End Anchorage VSL Type L

Dead-End Anchorage VSL Type L


5-4
5-7
5-12
5-19
5-22
5-31

A Int/ext

B Int/ext

R min.

50/55
65/72
80/87
90/97
95/102
110/117

45/50
55/60
65/72
80/87
85/92
100/107

600
600
900
1,100
1,200
1,400

Strand
Type 0.6

Strand
Type 0.5

Tendon Unit

6-2
50/55
45/50
600
6-3
50/55
45/50
600
6-4
55/60
50/55
600
6-7
75/82
60/67
750
6-12
90/97
80/87
1,000
6-19
100/117
95/102
1,300
Dimensions in mm.
Dimensions are valid for nominal concrete strength:
28 MPa (cube), 23 MPa (cylinder), at the time
of stressing, for a maximum stressing force
of 80% of the tendon breaking load.

Dead-End Anchorage VSL Type AF

Dead-End Anchorage VSL Type AF for vertical tendons


Tendon Unit

6-12
265
700
60
460
90
95/102
380
450
16
9
60
410
60
460
90
120/127
480
540
18
9
60
510
6-19
315
700
60
660
90
150/157
620
660
20
11
80
650
6-31
375
900
Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
Maximum prestressing force (80% of minimum tendon breaking load) may be applied when mortar of first injection
in the AF anchor reaches 100 MPa (cube).
n: number of spiral turns or ortogonal stirrups.
X: anchorage spacing, minimum clearance to edge Xc = 0.5*X + cover.

Multistrand Post - Tensioning

VSL

Ducts PT-PLUSTM System

Type

Unit

0,5
5-12
59
5-19
76
5-31
100
5-37
130
Dimensions in mm.

10

0,6
6-7
6-12
6-19/22
6-31

58
76
100
130

63
81
106
136

73
91
116
146

2.5
2.5
3.0
3.0

42.0
52.5
60.0
50.8

82
100
123
156

108
116
126
139

106
124
147
177

Corrugated Steel Ducts


Sizes of the Ducts and Eccentricity of the Centre
of Gravity of Strands

Tendon unit
5-1
5-3
5-4
5-7
5-12
5-19
5-22
5-31
5-37
5-42
5-55
Dimensions in mm.

Dia. of Duct
int/ext

Eccentricity

Tendon Unit

Dia. of Duct
int/ext

Eccentricity

20/25
35/40
40/45
50/57
65/72
80/87
85/92
100/107
120/127
130/137
140/150

4
7
7
8
11
13
12
14
23
26
23

6-1
6-2
6-3
6-4
6-7
6-12
6-19
6-31
6-37

25/30
35/40
40/45
45/50
60/67
80/87
100/107
130/137
140/150

5
6
6
6
10
14
17
22
25

Dimensions in mm.

Multistrand Post - Tensioning

VSL

Block Out Dimensions and Clearance Requirement


Jack Type A min.
ZPE-23FJ
ZPE-30
ZPE-3
ZPE-60
ZPE-7A
ZPE-12St2
ZPE-200
ZPE-19
ZPE-460/31
ZPE-500
ZPE-750
ZPE-1000
ZPE-1250
Dimensions in mm.

30
30
30
30
50
50
50
60
80
80
80
90

300
600
550
650
800
700
1,100
850
700
1,150
1,350
1,300
1,350

1,200
1,100
1,000
1,100
1,200
1,300
2,100
1,500
1,500
2,000
2,300
2,200
2,250

116
140
200
180
300
310
330
390
485
585
570
790
660

90
100
150
140
200
200
210
250
300
330
365
450
375

11

Stressing Jack Data

Type I (ZPE-23FJ)
Designation
Type
Length
(mm)
Diameter
(mm)
Stroke
(mm)
Piston area (cm 2)
Capacity
(kN)
Pressure
(bar)
Weight
(kg)
Used for 13 mm
(0.5'') tendon types
Used for 15 mm
(0.6'') tendon types

Type II (ZPE-19)

ZPE-23FJ ZPE-30
I
790
116
200
47.1
230
488
23
5-1

III
720
140
250
58.32
320
549
28
5-1

6-1

6-1

Type III (ZPE-500)

ZPE-3

ZPE-60

ZPE-7A ZPE-12St2 ZPE-200

ZPE-19

ZPE-460/31 ZPE-500 ZPE-750 ZPE-1000 ZPE-1250

III
475
200
160
103.6
500
483
47
5-2
5-3
6-2

III
615
180
250
126.4
632
500
74
5-2
to 5-4
6-2
6-3

III
690
280
160
203.6
1,064
523
115
5-6
5-7
6-4

II
750
390
100
500.3
2,900
580
294
5-18
5-19
6-12

II
580
485
100
804
4,660
580
435
5-22
5-31
6-18
6-19

II
550
310
100
309.4
1,850
598
151
5-12

III
960
315
300
325.7
2,000
614
305
5-12

6-6
6-7

6-6
6-7

III
II
III
II
1,000
1,185 1,200 1,290
550
520
790
620
200
150
200
150
894.6 1,247.00 1,809.50 2,168.00
5,000
7,500 10,000 12,500
559
601
553
577
1,064
1,100 2,290 1,730
5-22
5-31
5-37
5-37
5-31
5-37 to 5-55 to 5-55
6-18
6-31
6-31
6-31
to 6-22
to 6-43 to 6-55

Bonded Slab Post - Tensioning System

VSL

Stressing Anchorage VSL Type SO

12

K-30
75
110 1.5 x K
10
SO 5-4
306
144
250
96
65
103
K-30
75
120 1.5 x K
12
SO 6-4
330
168
280
115
75
127
Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 20 MPa (cube), 16 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
1) Use actual K when calculating H.
2) L shall be the maximum permitted by the slab thickness and cover, whereas Lm i n = 1.5 x K.

14
16

370
400

Type

H1)

Kmin

Lmin 2)

Dimensions of Ducts
Tendon unit

18

21

72

75

0.3

21

35

72

86

2.0

5-4
Steel Duct
Polyethylene
Duct
PT-PLUS T M
Dimensions in mm.

6-4
5-4
6-4

Bonded Slab Post - Tensioning System

VSL

Dead-End Anchorages VSL Type H and Type P


Type H

Type

H 5-4
310
70
930
H 6-4
90
950
Dimensions in mm.
Dimensions are valid for nominal concrete strength: 20 MPa (cube), 16 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

Type P

13
Type

2E

H 5-4
230
65
360
H 6-4
80
430
Dimensions in mm.
Dimensions are valid for nominal concrete strength: 20 MPa (cube), 16 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

Coupler VSL Type SK

Type

SK 5-4
408
150
140
170
Dimensions in mm.
Dimensions are valid for nominal concrete strength: 20 MPa (cube), 16 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

Bonded Slab Post - Tensioning System

VSL

Stressing Jack Clearance Requirements

Jack Type
ZPE-23FJ
DKP-5
DKP-6

Tendon unit

A (mm)

B (mm)

C (mm)

5-4

1,100

260

280

6-4
5-4
6-4

1,100
1,000
1,200

260
260
400

300
270
300

Stressing Jack Data

14

ZPE-23FJ

Jack Type
A
B
C
D
Stroke
Piston area
Capacity
Pressure
Weight

(mm)
(mm)
(mm)
(mm)
(mm)
(cm2)
(kN)
(bar)
(kg)

790
116
195
200
47.10
230
488
23

DKP-5
560
162
105
150
200
31.03
147
473
19

DKP-6
615
240
84
165
200
49.26
230
467
30

Monostrand Post - Tensioning System

VSL

Stressing Anchorage VSL Type S-6

* for 20-mm cover, to be adjusted for other values as needed.


Dimensions in mm.
Dimensions are valid for nominal concrete strength: 24 MPa (cube), 20 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

Dead-End Anchorage VSL Type SF-6


15

Dimensions in mm.
Dimensions are valid for nominal concrete strength: 24 MPa (cube), 20 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

Coupler VSL Type SK-6

Dimensions in mm.
Dimensions are valid for nominal concrete strength: 24 MPa (cube), 20 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.

External Post - Tensioning System

VSL

Stressing Anchorage VSL Type E

Strand
Type 0.6

Tendon Unit
A

L 2)

Mmin

80
120
150
170
220
300
370
400
470
520

18
50
56
65
84
118
150
172
192
215

10
15
25
25
35
45
55
60
75
80

53
90
95
110
135
170
200
220
260
280

50
50
50
55
60
75
95
100
120
135

80
80
80
85
90
105
125
130
150
165

100
145
185
215
290
380
480
520
620
680

100
150
150
200
250
330
420
420
520
585

8
10
10
12
14
16
18
18
20
22

50
50
50
50
50
55
60
60
65
65

2.5
3.5
3.5
4.5
5.5
6.5
7.5
7.5
8.5
9.5

70
190
190
190
190
370
530
650
690
830

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
1) Bearing plate also made of cast iron.
2) L: number of spiral turns if the last spiral turn is welded, or L + 1 if the last spiral is opened.

Stressing Anchorage VSL Type Ec

Tendon Unit

Strand
Type 0.6

16

6-1
6-2
6-3
6-4
6-7
6-12
6-19 1)
6-22
6-31 1)
6-37 1)

Dimensions

6-3
6-4
6-7
6-12
6-19
6-22
6-31
6-37

Dimensions
A

135
150
190
250
310
340
390
430

95
110
135
170
200
220
260
280

C
65
77
96
115
135
135
165
175

L 1)

100
115
145
190
235
255
295
320

125
155
170
245
305
365
350
450

50
55
60
75
95
100
120
135

80
85
90
105
125
130
150
165

50
60
55
60
65
67
70
80

3
4
5
6
7
8
8
9

160
200
250
330
400
430
510
550

145
210
260
345
440
480
540
605

10
12
14
16
18
18
22
22

45
50
50
55
60
60
65
65

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
1) L: number of spiral turns.

External Post - Tensioning System

VSL

Stressing Anchorage VSL Type Ed

Strand
Type 0.6

Tendon Unit
6-7
6-12
6-19
6-31
6-37

Dimensions
A

N 1)

250
310
390
430
520

245
305
350
450
530

60
65
70
80
90

175
225
275
305
320

95
115
145
155
183

75
90
110
125
140

190
235
295
320
420

100
115
135
160
170

45
45
45
55
55

345
235
540
605
745

16
18
22
22
26

55
60
65
65
80

330
400
510
550
640

6
7
8
9
9

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
Special anchorage permitting easy tendon replacement.
1) N: number of spiral turns.

17

Stressing Anchorage VSL Type Edm

Strand
Type 0.6

Tendon Unit
6-1
6-2
6-3
6-4
6-7
6-12
6-19
6-22
6-31
6-37

Dimensions
A

BMIN

80
120
150
170
220
300
370
400
470
520

35
155
155
145
145
325
485
605
635
775

10
15
25
25
35
45
55
60
75
80

35
35
35
45
45
45
45
45
55
55

Dimensions in mm.
Dimensions are valid for:
Nominal concrete strength: 28 MPa (cube), 23 MPa (cylinder), at the time of stressing,
for a maximum stressing force of 80% of the tendon breaking load.
Special anchorage permitting easy tendon replacement..
Spirals: according to the dimensions of the opening at the anchorage.

Ground Anchors

VSL

VSL Permanent Anchors (K1)


Number
of strands
13 mm
(0.5)

Ultimate
capacity based
on 0.5S strand

Weight
of
strands

Cross sectional
area

Diameter Anchor
RA without Pi,
GA with Pi
(mm)
90
90
100
120
130

GA
without Pi
(mm)
85
85
95
115
125

GA
with Pi
(mm)
95
95
105
125
135

(kN)
(kg / m)
(mm2)
3
558
2.4
300
4
744
3.1
400
7
1,302
5.5
700
12
2,232
9.4
1,200
19
3,534
14.9
1,900
Data for anchors with higher capacity on request
Dimensions are same for ASTM A 416 strands, with respective ultimate capacity.
Drill hole diameter is approx. 20 mm bigger than anchor diameter, but need to be confirmed by local
drilling company.
For dimensions of anchorages and other data please contact your local VSL office.
- K1
:
Permanent Anchor.
- GA:
Ground Anchor.
- RA:
Rock Anchor.
- Pi :
Post-Injection.

VSL Temporary Anchors (K2 and K3)


18
Number
of strands
13 mm
(0.5)

Ultimate
capacity based
on 0.5S strand

Weight
of
strands

(kN)
(kg / m)
3
558
2.4
4
744
3.1
7
1,302
5.5
12
2,232
9.4
19
3,534
14.9
Data for anchors with higher capacity on request
K2:
with external spacer for thick grout cover.
K3:
without external spacer.

Cross sectional
area
(mm2)
300
400
700
1,200
1,900

Max. diameter of anchors


with or without post-injection
Type K2
(mm)
83
83
90
99
119

Type K3
(mm)
48
48
64
74
84

VSL Extractable Anchors (extractability of free length)


Number
of strands
15 mm
(0.6)

Ultimate
capacity based
on 0.6S strand

Test
load

Weight
of
strands

Cross sectional
area

Max.
diameter
of anchor

(kN)
(kN)
(kg / m)
(mm2)
(mm2)
300
90
2
379
323
2.4
450
90
3
568
485
3.5
600
90
4
758
647
4.7
750
90
5
948
808
5.9
900
100
6
1,137
970
7.1
1,050
100
7
1,327
1,132
8.2
Data for anchors with higher capacity on request
Dimensions are same for ASTM A 416 strands, with respective ultimate capacity.
Drill hole diameter is approx. 20 mm bigger than anchor diameter, but need to be confirmed by local drilling company.
For dimensions of anchorages and other data please contact your local VSL office.
Please note reduced strands ultimate capacity to permit extractability.

S-ar putea să vă placă și