Vol. 4 No. 2
Biodegradable composites
Following injuries such as bone
fracture or damage, a replacement
for the destroyed material might be
necessary for the successful recovery
of the patient. Currently, autografting
Vol. 4 No. 2
49
Fig. 2 Interference screws made by injection moulding of PLA (left), hydroxyl apatite
(centre), and 316L stainless steel (right)
50
Vol. 4 No. 2
Vol. 4 No. 2
Towards production of
micro implants
In order to demonstrate the potential of
PIM regarding precision and reproducibility the smallest bone in the human
ear, the stapes, was replicated under
series production conditions. Design
and manufacturing of the micro injection mould was performed by Kraemer
Engineering, Rendsburg, Germany.
Initial process setup was conducted
using ultrafine stainless steel powder,
as presented in Fig. 6.
Since biocompatible materials are
required for medical implants the investigations were determined with titanium.
A titanium grade 1 powder with d50
about 15 m was used for the Titanium
feedstock preparation. In comparison
to conventional PIM the amount of
backbone polymer inside the binder
system was increased from approx.
25 % to 50 % to ensure the replication
of the small component structures.
Because of the higher polymer content,
feedstock and mould temperatures had
to be raised approximately 25C during
the injection moulding process, which
51
Conclusion
Fig. 7 Measurement positions for determining the tolerances of the titanium stapes
Authors
Janne Haack Dipl.-Ing. (FH), Dr. Philipp
Imgrund, Dr. Sebastian Hein, Vera
Friederici, Dr. Natalie Salk
Biomaterials Technology
Fraunhofer-IFAM
Wiener Strae 12
28359 Bremen, Germany
Tel: +49 421 2246 216
Fax: + 49 421 2246 300
philipp.imgrund@ifam.fraunhofer.de
Acknowledgments
Fig. 8 Weight measurements of 90 titanium stapes
MP1
MP2
MP3
MP4
MP5
Weight [mg]
714
1507
287
2284
263
5.31
94
13
10
0,03
13.1
0.9
3.3
0.4
3.3
0.6
52
References
[1] Stevens B, Yang Y, Mohandas A,
Strucker B, Nguyen K T, J. Biomed
Mater Res Part B: Appl Biomater, 2008,
85B, 573-582
[2] Rezwan K, Chen Q Z, Blaker J J,
Boccaccini A R, Biomaterials, 2006, 27,
3413-3431
[3] Bruinink A, Kaiser P, Meyer C,
Advanced Engineering Materials, 2005,
Vol. 7, Issue 5, 411-418
[4] Cooper L F, Journal of Prosthetic
Dentistry, 2000, 84, 522-534
[5] Tsyganov I, Maitz M F, Wieser E,
Richter E, Reuther H, Surface and Coatings Technology, 2005, 200, 1041-1044
[6] Imgrund P, Rota A, Simchi A, Journal
of Materials Processing Technology,
2008, 200, 259-264
[7] Quinard C, Barriere T, Gelin J C,
Powder Technology 2009, 190, 123128
[8] MIM-Expertenkreis im Gemeinschaftsausschuss Pulvermetallurgie
MIM-Tolerances, 2002
[9] Imgrund P, Plaggenborg T, Mikroproduktion, 2008, 04, 24-29
Vol. 4 No. 2
Postcode....................................................................................Country............................................................................................
Tel: .............................................................................................. Fax: ....................................................................................................
E-mail: ........................................................................................
Subscription period
Powder Injection Moulding International is published on a quarterly basis.Your subscription will commence with the next
available issue unless otherwise requested (please email paul@inovar-communications.com)
Payment options
Please invoice me. I understand that subscriptions will not start until full payment is made.
Please charge .............. to my credit card as follows: VISA MasterCard American Express
Name on Card:..................................................................................................................................................
Card Number:........................................................................................... 3/4 Digit Security Code ...........
Expiry Date:............................................................................................... .
.
Signature:.................................................................................................... Date:...............................................
www.pim-international.com
Vol. 4 No. 2
53
www.pim-international.com