MY TR TH XCH TAY

MY TR TH XCH TAY

Seri Pneume cung cp tin nghi tin tin

Cng ngh c o vi hiu sut cao


02 Stream(iu tr lu lng cao)
ACPAP+
Kh nng t to kh

Pneuma Series Features


Pneuma 1
Dual Limb

MODE

Pneuma 2

Single Limb *Single Limb*


Ex-Valve

Dual Limb

Single Limb *Single Limb*


Ex-Valve

PACV
PSIMV
VACV
VSIMV
AUTO (Emergency quick start)
Spont+
PRVC
O2Stream
ACPAP+
ABIPAP+

Trend

Trend (72hrs)

Peripherals

High Pressure Oxygen Mixer


Low Flow Oxygen Supply Inlet
Exhalation Drive Line Input
Proximal Pressure Line Input

Optional

Nasal Cannula for O2Stream


SpO 2
EtCO 2
Remark : *single limb * - Single limb circuit with external exhalation valve

Head Office / 1st Factory

Branch Office / 2nd Factory

Industrial Zone 861-10, Toegye-dong, Chuncheon-si,


Gangwon-do, Korea
(ZIP code 200-944)

5th Floor, A-dong, Woolimlionsvalley 5th.


#144-3,4 Sangdaewon-dong, Jungwon-gu, Seongnam-si,
Gyeonggi-do, South Korea (ZIP code 462-739)

TEL: +82. 70. 7119. 2540


FAX: +82. 33. 264. 5999
e-mail: sales@mek-ics.com
www.mek-ics.com

TEL: +82. 70. 7119. 2520


FAX: +82. 31. 735. 2761
e-mail: sales@mek-ics.com
www.mek-ics.com

0470

MTV 1000

Multi Purpose Ventilator for

Hospital, Long Term Care and Transport

Pneuma1
Dual Limb Circuit >
PACV, PSIMV, VACV, VSIMV, Spont(Spont+PS) , PRVC,
Apnea Back-up Ventilation, AUTO(Emergency Quick Start)

Mn
hnh
mu
TFTScreen
7"
7
Color
TFT
Touch

Nm
iufor
chnh
thit
lp thng s
Encorder
setting
parameter

Single Limb Circuit >


PACV, PSIMV, PRVC, Apnea Back-up Ventilation.
ACPAP+, ABiPAP+
Optional : SpO2, EtCO2

Optional
: SpO2,
La chn
thm:EtCO2
Sp02, EtC02

Pneuma2
Dual Limb Circuit >
PACV, PSIMV, VACV, VSIMV, Spont(Spont+PS),
PRVC, AUTO(Emergency Quick Start), Apnea Back-up Ventilation.

Single Limb Circuit >


PACV, PSIMV, PRVC, Spont(Spont+PS), Apnea Back-up
Ventilation, ACPAP+, ABiPAP+,
O2 Stream with high flow oxygen supply.
with High Pressure Oxygen Mixer
Optional : SpO2, EtCO2, Nasal Cannula for O2Stream

u vo Pressure
p lc dng
Proximal
Line gn
Input
u ra thot
hiLine
thOutlet
Exhalation
Drive

PSV

Pneuma1

LAN,
Upgrade
NngUSB
cp RS-232
cng LAN,
USB,Port
RS-232

Quick Pause
Pressure

=Easy Expiration

Trigger
Flow-Machine
Ex.time

H tr p lc CPAP+ thch nghi


O2 stream

Hospital.
Bnh
Vin

Home Care.
Chm
sc gia nh

Transport.
Vn
chuyn

Recently
themc
clinical
aimlm
of ventilator
minimized
of lung
Gn y
ch
sng caismy
th c
gim thiu
injury
and recovered
spontaneous
respiration.
should
tn
thng
phi v of
phc
hi h hp
t nhin.It N
s c tha
thun
cchthat
cninterrupt
thn m
lm gin
h thng thng
be dealvi
withmt
carefully
ventilation
andon
assistance
gi
v h tr
trongAfter
lmweaning
sng. Sau
khi cai my
bng h
of breathing
in th
clinically.
by ventilation,
it may
thng
my
th,
n
c
th
xy
ra

s
dng
my
th
happen to use the ventilator (or assistance of breathing) (hoc h
tr
th)
li thng
la method
mt phng
php
cn thit h
again
frequent.
That xuyn.
is necessary
for proper
and
tr
th
thch
hp
v
hiu
qu.
effective assistance of breathing.
Cc
lu
lng
cao tr
liu l thit
b ph
hp
vi phng
The
High
Flow
Therapy
is suitable
device
for the
method
php ny. Trong kha cnh ny, n khc vi CPAP mi. Chc
and it is contrived by principal that makes sufficient ventilation
nng ny c s dng vi ng thng mi c sng ch c
in the nasal cavity and upper airway. In this aspect, it is
bit v s dng vi m.
different from Nasal CPAP. This function is using with Nasal
Cannula was contrived specially and use with humidifier.

Flow-Patient

ACPAP+
(Adaptive CPAP Plus Pressure Support)
[ACPAP+ Function]
It isN
developed
withtrin
high vi
technology
whichcao,
applying
to the
c pht
cng ngh
p dng
cho
my th
khoa
Hi
sc tch
cc
bc cao
v bnh
highest
class
ICU
ventilator
and
applying
for nht
a patent.
It is
nhn. Nreaserch
c i
micomfortable
d n nghin
cu "thoi
mi
innovated
object
breathing
in CPAP.
khi
Th
"
trong
CPAP.
MEKICS
to
ra
cng
ngh
MEKICS created unique ACPAP+ technology completed
ACPAP+
duy nht
hon thnhbreathing
ng thi
hiu qu lm
the
clinical effect
and comfortable
simultaneous.

sng v thoi mi trong lc th.

[Principal]
Based
theCPAP,
CPAP, it
contrived
to ch
minimize
breaths
Daon
trn
nisc
sng
tiofthiu
hi
th kh
khn
CPAP
nh of
cm
ngopen,
h ng
with
difficulty
in trong
CPAP as
induction
airway
pressure
th, h that
tr p
lc cpatients
gim n
lc inca
bnh nhn,
support
is decreased
effort
inspiration,
and
v
gin
on
tch
cc
(ngt
p
lc
nhanh)
lm cho
active break (rapid pressure interruption) that makes
easyth
dexpiration.
dng hn.
of

[Technology]
It isN
decreased
Inspiratory
Phase
Work
Breathing
through
c gim
th giai
on
ht of
vo
thng qua
chc
nng kch Trigger
hot(Trigger)
v chc
nng function.
h tr pIt lc.
Inspiratory
functionht
andvo
Pressure
Support
N lmpossible
cho ctoth
ht phiwith
vismall
n lc
nh
bnh
nhn
makes
inhalation
effort
of ca
patient
(WOB_
(WOB_inspiration).
inspiration). It is decreased Expiratory Phase Work of Breathing
N c
gim th
giai
th the
ra thng
qua and
through
Ex_Sesnse.
In this
time,on
interrupt
flow rapidly
Ex_Sense(
nhy
th
ra
c
th
iu
chnh
c).
supply brk_time (Expiration Break Time). It makes possibleTrong
to
thi gian ny, gin on dng chy nhanh chng v cung
exhalation with small effort of patient (WOB_expiration) and
cp brk_time (thi gian gin on th ra). N lm cho c th
minimize of breaths with difficulty.

th ra vi n lc nh ca bnh nhn (WOB_expiration) v


gim thiu hi th mt cch kh khn.

* (brk_time: Expiration Break Time): Application to most


convenience respiration pattern.

S-ar putea să vă placă și