1)
Suction line
Dimension the suction line so that the flow speed at maximum delivery rate
does not exceed 1 m/s. If this is not taken into account, the required suction
head Hz (as specified in the offer or data sheet ) must be increased by the
losses within the suction line. Also include flow losses by installing internal
fittings such as screens.
At the top, the upper line must run straight without increases, otherwise gas
or steam bubbles may separate, possibly reaching the pump in clusters.
This causes noise and pressure fluctuations.
2)
Gas bubble
3)
4)
5)
Pressure conduit
The pressure line is to be installed to rise continually! If this is impossible, the manufacturer
should be consulted.
Efficient flow speeds are approx. 1.5 3 m/s according to the length of the pressure line.
The installation of a check valve or a non-return valve must be avoided, if the pump is also
operated at zero delivery or very small flow volumes, since the installation can cause vibrations
and pressure fluctuations within the pressure line.