technical catalogue
Tmax T6.
New PR223EF and PR223DS
electronic releases
Preliminary - 1SDC210012D0201
OVERVIEW
THE RANGES
ACCESSORIES
CHARACTERISTIC CURVES
AND TECHNICAL
INFORMATION
WIRING DIAGRAMS
OVERALL
DIMENSIONS
ORDERING
CODES
T4 T5 T6
THE T GENERATION HAS GROWN.
State-of-the-art electronics
Apart from the PR221DS and PR222DS/P already
Tmax. T Generation.
EFDP
NEW PR223EF RELEASE. FREE THE INSTALLATIONS, WITH
LEVELS OF SELECTIVITY NEVER ACHIEVED BEFORE.
[A]
[A]
[No]
[V]
[V]
[kA]
[kA]
[kA]
[kA]
[kA]
[kA]
[kA]
(AC) 50 - 60 Hz
(DC)
B
C
N
S
H
L
V
[A]
[No]
[V]
(AC) 50 - 60 Hz
[A]
[No]
[V]
(AC) 50 - 60 Hz
[A]
[No]
[kA]
[kA]
1000 V AC
1000 V DC 4 poles in series
Switch-disconnectors
Ith
Ie (AC23)
Poles
Ue
[A]
[A]
[No]
[V]
Icm
Icw
[kA]
[kA]
(AC) 50 - 60 Hz
(DC)
Note: ABB SACEs moulded-case circuit-breakers are also available in the versions according to UL Standards (see
catalogue ABB SACE molded case circuit-breakers - UL 489 and CSA C22.2 Standard).
T1 1p
T1
T2
T3
T4
T5
T6
160
16160
1
240
125
25* (220/230 V AC)
160
16160
3/4
690
500
16
25
36
160
1,6160
3/4
690
500
16
25
36
50
70
85
250
63250
3/4
690
500
250/320
20320
3/4
690
750
400/630
320630
3/4
690
750
630/800/1000
6301000
3/4
690
750
36
50
36
50
70
120
200
36
50
70
120
200
36
50
70
100
T4
T5
T6
250/320
3/4
690
400/630
3/4
690
630/800/1000
3/4
690
T2
T3
T4
T5
T6
160
3
690
250
3
690
250/320
3
690
400/630
3
690
630/800/1000
3
690
T4
T5
T6
250
3/4
20
40
400/630
3/4
20
40
630/800
3/4
12
40
T1D
T3D
T4D
T5D
T6D
160
125
3/4
690
500
2.8
2
250
200
3/4
690
500
5.3
3.6
250/320
250/250
3/4
690
750
5.3
3.6
400/630
400/400
3/4
690
750
11
6
630/800/1000
630/800/800
3/4
690
750
30
15
The ranges
1
Index
Tmax circuit-breakers for power distribution
Electrical characteristics .........................................................................................................1/2
General characteristics............................................................................................................1/4
Thermomagnetic releases .......................................................................................................1/5
Electronic releases ..................................................................................................................1/6
Switch-disconnectors
Electrical characteristics .......................................................................................................1/20
ABB SACE
1/1
Interchangeability
Versions
Terminals fixed
withdrawable
plug-in
Fixing on DIN rail
Mechanical life
Electrical life @ 415 V AC
Basic dimensions - fixed version
Weight
fixed
withdrawable
plug-in
KEY TO TERMINALS
F = Front
1/2
(AC) 50-60 Hz
(DC)
[A]
[Nr]
[V]
[V]
[kV]
[V]
[V]
[kA]
[kA]
[kA]
[kA]
[kA]
[kA]
[kA]
[kA]
[kA]
[kA]
[%Icu]
[%Icu]
[%Icu]
[%Icu]
[%Icu]
[kA]
[kA]
[kA]
[kA]
[kA]
[ms]
TMF
TMD
TMA
TMG
TMG
PR221DS-LS/I
PR221DS-I
PR222DS-LSI
PR222DS-LSIG
PR222DS/PD-LSI
PR222DS/PD-LSIG
PR223DS
[No. operations]
[No. Hourly operations]
[No. operations]
[No. Hourly operations]
W [mm]
4 poles
W [mm]
D [mm]
H [mm]
3/4 poles
[kg]
3/4 poles
[kg]
3/4 poles
[kg]
EF = Front extended
ES = Front extended spread
Tmax T1 1P
Tmax T1
160
1
240
125
8
500
3000
B
25*
25 (at 125 V)
B
25
16
10
8
3
16
20
16
160
3/4
690
500
8
800
3000
C
40
25
15
10
4
25
30
25
N
50
36
22
15
6
36
40
36
N
65
36
30
25
6
36
40
36
S
85
50
45
30
7
50
55
50
75%
100%
100%
100%
100%
100%
75%
100%
75%
75%
75%
75%
75%
50%
50%
50%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100% 75% (70 kA)
100%
75%
100%
75%
100%
75%
52.5
7
A
IEC 60947-2
52.5
32
17
13.6
4.3
7
84
105
52.5
75.6
30
46.2
17
30
5.9
9.2
6
5
A
IEC 60947-2
143
75.6
63
52.5
9.2
3
187
105
94.5
63
11.9
3
220
154
121
75.6
13.6
3
F
FC Cu
25000
240
8000
120
25.4 (1 pole)
70
130
0.4 (1 pole)
F
FC Cu-EF-FC CuAl-HR
DIN EN 50022
25000
240
8000
120
76
102
70
130
0.9/1.2
Tmax T2
160
3/4
690
500
8
800
3000
R = Rear orientated
MC = Multicable
H
100
70
55
36
8
70
85
70
L
120
85
75
50
10
85
100
85
264
187
165
105
17
3
IEC 60947-2
F-P
F-FC Cu-FC CuAl-EF-ES-R
F-FC Cu-FC CuAl-EF-ES-R
DIN EN 50022
25000
240
8000
120
90
120
70
130
1.1/1.5
1.5/1.9
F = Fixed circuit-breaker
P = Plug-in circuit-breakers
ABB SACE
Tmax T3
Tmax T4
Tmax T5
Tmax T6
250
3/4
690
500
8
800
3000
L
200
120
100
85
70
100
70
50
V
300
200
180
150
80
150
100
70
N
70
36
30
25
20
36
25
16
400/630
3/4
690
750
8
1000
3500
H
100
70
65
50
40
70
50
36
630/800/1000
3/4
690
750
8
1000
3500
S
H
85
100
50
70
45
50
35
50
22
25
50
70
35
50
20
36
L
200
100
80
65
30
100
65
50
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100% 100%
100% 100%
100% 100%
100% 100%
100% 100%(1)
100%
100%
100%
100%
75%
75%
75%
75%
75%
75%
660
440
396
330
176
5
154
75.6
63
52.5
40
6
187
220
440
105
154
264
84
143
220
63
105
187
52.5
84
154
6
6
6
B (400 A)(3) - A (630 A)
IEC 60947-2
N
50
36
25
20
5
36
40
36
S
85
50
40
30
8
50
55
50
N
70
36
30
25
20
36
25
16
S
85
50
40
30
25
50
36
25
250/320
3/4
690
750
8
1000
3500
H
100
70
65
50
40
70
50
36
75%
75%
75%
75%
75%
50%
50% (27 kA)
50%
50%
50%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
105
75.6
52.5
40
7.7
7
187
105
84
63
13.6
6
154
75.6
63
52.5
40
5
187
105
84
63
52.5
5
IEC 60947-2
F-P
F-FC Cu-FC Cu Al-EF-ES-R
F-FC Cu-FC Cu Al-EF-ES-R
DIN EN 50022
25000
240
8000
120
105
140
70
150
1.5/2
2.7/3.7
W = Withdrawable
circuit-breakers
220
440
154
264
143
220
105
187
84
154
5
5
A
IEC 60947-2
(up to 50 A)
(up to 250 A)
F-P-W
F-FC Cu-FC CuAl-EF-ES-R-MC
EF-ES-HR-VR-FC Cu-FC CuAl
EF-ES-HR-VR-FC Cu-FC CuAl
20000
240
8000 (250 A) - 6000 (320 A)
120
105
140
103.5
205
2.35/3.05
3.6/4.65
3.85/4.9
(*) The breaking capacity for settings
In=16 A and In=20 A is 16 kA
S
85
50
40
30
25
50
36
25
L
200
120
100
85
70
100
70
50
V
300
200
180
150
80
150
100
70
N
70
36
30
25
20
36
20
16
100%
100%
100%
100%(1)
100%(2)
100%
100%
100%
100%(2)
100%(2)
100%
100%
100%
100%
75%
660
440
396
330
176
6
(up to 500 A)
(up to 500 A)
F-P-W
F-FC Cu-FC CuAl-EF-ES-R
EF-ES-HR-VR-FC Cu-FC CuAl
EF-ES-HR-VR-FC Cu-FC CuAl
20000
120
7000 (400 A) - 5000 (630 A)
60
140
184
103.5
205
3.25/4.15
5.15/6.65
5.4/6.9
(1)
100%
100%
100%
100%
75%
154
187
220
440
75.6
105
154
220
63
94.5
105
176
52.5
73.5
105
143
40
46.2
52.5
63
10
9
8
7
B (630A - 800A) - A (1000A)
IEC 60947-2
(4)
F-W
F-FC CuAl-EF-ES-R-RC
EF-HR-VR(4)
20000
120
7000 (630A) - 5000 (800A) - 4000 (1000A)
60
210
280
103.5
268
9.5/12
12.1/15.1
(3)
ABB SACE
1/3
General characteristics
The new Tmax series of moulded-case circuit-breakers, complying with the IEC 60947-2 Standards,
is widened with the new T6 size, which extends the range of application from 630 A up to 1000 A
with breaking capacities from 36 kA to 100 kA (at 380/415 V AC).
For the first time ABB SACE has developed a moulded-case circuit-breaker with rated current of 1000 A
which offers an alternative and more compact solution than a circuit-breaker of a larger size.
Dimensionally the new T6 has the same depth as T4 and T5 (D = 103.5 mm) therefore guaranteeing
a high level of standardisation of the metalwork structures, whereas a pole pitch of 70 mm makes
connection of the circuit-breaker terminals inside the switchgear convenient.
The protection releases which can be mounted on T6 to carry out protection of networks in alternating current are as follows:
TMA thermomagnetic releases with adjustable thermal threshold (I1 = 0.7...1 x In) and adjustable
magnetic threshold (I3 = 5...10 x In)
PR221DS, PR222DS/P, PR222DS/PD electronic releases
the new PR223DS and PR223EF releases.
The range of use in alternating current of the Tmax series varies, with T6 from 630 A up to 1000 A
with voltages up to 690 V.
The Tmax T6 circuit-breakers equipped with TMA can also be used in direct current installations, with
an application range from 630 A to 800 A and a minimum operating voltage of 24 V DC according
to the suitable wiring diagrams.
Interchangeability
The Tmax T6 circuit-breakers can be fitted either with
TMA thermomagnetic releases
or PR221DS, PR222DS/P,
PR222DS/PD, PR222MP and
Releases
TMA
Circuit-breakers
In (A)
630
800
T6 630
T6 800
T6 1000
PR221DS-LS/I or I
630
800
1000
800
1000
630
800
1000
630
PR223DS
PR222MP
800
630
1000
Range (A)
TMA
PR221DS
PR222DS/P
PR222DS/PD
PR223DS
630800
6301000
6301000
6301000
6301000
TMA
630800
AC
T6 630/800/1000
DC
T6 630/800
1/4
ABB SACE
Thermomagnetic releases
The Tmax T6 circuit-breakers can be equipped with thermomagnetic releases and are used for
protection of networks in alternating current and in direct current, with a range of uses from 630 A
to 800 A. They allow protection against overloads with a thermal device with adjustable threshold
made using the bimetal technique, and protection against short-circuit with a magnetic device with
adjustable threshold.
The four-pole circuit-breakers are available with the neutral setting at 50% or at 100% of the phase
setting.
Thermal threshold
Adjustable
Thermal threshold
1SDC210213F1002
TMA = thermomagnetic release with adjustable thermal threshold (I1 = 0,71 x In) and magnetic threshold (I3 = 510 x In)
TMA - T6
In [A]
630
800
630
800
400
500
I3 [A]
31506300
40008000
31506300
40008000
20004000
25005000
ABB SACE
1/5
General characteristics
The Tmax T6 circuit-breakers, for use in alternating current, can be equipped with PR221DS, PR222DS
(in the version with protection only and with the dialogue function), and PR223DS overcurrent releases constructed using the electronic technique. This allows protection functions to be obtained
which guarantee great reliability, trip precision and insensitivity to the electromagnetic components
in compliance with the Standards on the matter. The power supply needed for correct operation is
supplied directly by the release current transformers and tripping is always guaranteed, even under
single-phase load conditions, and in correspondence with the minimum setting.
The protection releases are made up of the current transformers (three or four depending on the
number of conductors to be protected), of the PR221DS, PR222DS or PR223DS protection unit in
the different versions available, and of an opening solenoid with demagnetisation (SA) which acts
directly on the circuit-breaker control group and which is housed in the release box.
The current transformers, housed inside the release box, supply the energy required for correct operation of the protection and to provide the signal needed to determine the current. They are available
with primary rated current as shown in the table.
When the protection trips, the circuit-breaker opens by means of the opening solenoid (SA), which
changes over a contact (AUX-SA, available on request) for signalling that the release has tripped.
Recovery of the signal is of the mechanical type and is carried out by resetting the circuit-breaker
operating lever.
The test of the opening solenoid (SA) can be carried out by means of the SACE TT1 test device. A
positive outcome of the test coincides with circuit-breaker opening.
Caption
For further in-depth information, please see the
Tmax Low voltage moulded-case circuitbreakers up to 630 A technical catalogue.
-25 C+70 C
90%
4566 Hz
IEC 60947-2 Annex F
Current transformers
PR221DS
PR222DS/P, PR222DS/PD or
PR223DS
In [A]
T6
L
S
I
T6
L
S
I
G
630
252630
6306300
6306300
252630
3786300
9457560
126630
800
320800
8008000
8008000
320800
4808000
12009600
160800
1000
4001000
100010000
100010000
4001000
60010000
150012000
2001000
The PR221DS, PR222DS/P and PR222DS/PD electronic releases, which can be mounted on T6,
have the same characteristics as the releases for T4 and T5, except for the trip curves times of the
L function on the PR222DS/P electronic release (for further in-depth information, please see the
Characteristic curves and technical information chapter).
1/6
ABB SACE
PR221DS-LS/I
Protection S
Dip-switch for
setting the neutral
(only for T4, T5 and T6)
Against short-circuit
with delayed trip
Protection L
Against overload
Socket for TT1
test unit
1SDC210002F1002
Protection I
Against short-circuit
with instantaneous trip
PR222DS/P
Protection I
Protection S
Against short-circuit
with instantaneous trip
Against short-circuit
with delayed trip
Protection L
Against overload
1SDC210003F1002
PR222DS/PD
Protection I
Protection S
Against short-circuit
with instantaneous trip
Against short-circuit
with delayed trip
Protection L
Against overload
Dip-switch for
setting the neutral
1SDC210004F1002
ABB SACE
1/7
PR223DS
Apart from the traditional L, S, I, and G protection functions, the PR223DS release, available on T4,T5
and T6, offers the possibility of obtaining the voltage values and of displaying the main electrical
values by means of the FDU.
Setting the PR223DS release can only be carried out electronically, i.e. using the PR010/T test unit
(setting in local mode) or the dialogue function (setting in remote mode). The range and the steps
are exactly the same as the PR222DS with electronic setting. Furthermore, by means of the VM210
accessory and without the use of voltage transformers, the voltage values of the single phases can
be made available to the user.
The PR223DS, fitted with the VM210 module and the FDU preset with auxiliary power supply, can
show the current, voltage, power and energy measurements on the front of the circuit-breaker.
Measurements
With distributed N
Without distributed N
I1, I2, I3
Apparent powers
Active powers
Ptot
Reactive powers
Qtot
Power factors
cos
cos
ETOT
ETOT
Peak factor
Frequency
For the neutral, it is possible to set the protection threshold of the functions to OFF, at 50% and at
100% of that of the phases. Moreover, on the front of the release pre-alarm and alarm signalling of
protection L are also available. The value of the pre-alarm threshold is 0.9xI1. Again on the front of
the release, the LEDs are available, which signal the following information:
condition of the opening solenoid connection
use of the default parameter
mode (local or remote)
presence of the auxiliary power supply
setting of the neutral.
1/8
ABB SACE
PR223DS
LED signalling
the status of the
circuit-breaker
Socket for connection
of SACE PR010/T
test unit
1SDC210214F1002
Trip curves(1)
at 6 x I1
t1 = 318s (step 0.5s)(2)
Tolerance: 10%
Against short-circuit
with inverse short
time delay trip and
trip characteristic
with inverse time
(I2t= constant) or definite time
at 8 x In
t2 = 0.050.5s (step 0.01s)
Tolerance: 10%(4)
istantaneous 30 ms
Protection functions
NOT
EXCLUDABLE
EXCLUDABLE
I2t=cost ON
I2t=cost OFF
EXCLUDABLE
EXCLUDABLE
(1)
ABB SACE
(2)
(3)
(4)
1/9
(AC) 50-60 Hz
(DC)
Weight
fixed
plug-in
withdrawable
LEGENDA TERMINALI
EF = Front extended
F = Front
ES = Front extended spread
R = Rear orientated
MC = Multi-cable
1/10
T4
T5
T6
250/320
3/4
690
750
8
1000
3500
L
200
120
100
85
70
400/630
3/4
690
750
8
1000
3500
L
200
120
100
85
70
630/800/1000
3/4
690
750
8
1000
3500
L
200
100
80
65
30
100%
100%
100%
100%
100%
100%
100%
100%
100%(1)
100%(2)
75%
75%
75%
75%
75%
440
264
220
187
154
A
IEC 60947-2
F-P-W
F-FC Cu-FC CuAl-EF-ES-R-MC
EF-ES-HR-VR-FC Cu-FC CuAl
20000
240
8000 (250A) - 6000 (320A)
120
105
140
103.5
205
2.35/3.05
3.6/4.65
3.85/4.9
440
264
220
187
154
B (400A) - A (630A)
IEC 60947-2
F-P-W
F-FC Cu-FC CuAl-EF-ES-R-MC
EF-ES-HR-VR-FC Cu-FC CuAl
20000
120
7000 (630A) - 5000 (800A)
60
140
184
103.5
205
3.24/4.15
5.15/6.65
5.4/6.9
440
220
176
143
63
B (630A - 800A) - A (1000A)
IEC 60947-2
F-W
F-FC CuAl-EF-ES-R-RC
EF-HR-VR
20000
120
7000 (630A) - 5000 (800A) - 4000 (1000A)
60
210
280
103.5
268
9.5/12
12.1/15.1
[A]
[No]
[V]
[V]
[kV]
[V]
[V]
[kA]
[kA]
[kA]
[kA]
[kA]
[%Icu]
[%Icu]
[%Icu]
[%Icu]
[%Icu]
[kA]
[kA]
[kA]
[kA]
[kA]
PR223EF
[No. operations]
[No. Hourly operations]
[No. operations]
[No. Hourly operations]
W [mm]
4 poles
W [mm]
D [mm]
H [mm]
3/4 poles
[kg]
3/4 poles
[kg]
3/4 poles
[kg]
F = Fixed circuit-breaker
P = Plug-in circuit-breaker
W = Withdrawable circuit-breaker
(1)
(2)
ABB SACE
PR223EF
The PR223EF electronic release available on T4, T5 and T6 in the L version for use in alternating current, is able to isolate a fault present in the network much more rapidly than with the zone selectivity
currently present on the market: when with typical zone selectivity the extinction times are around a
few hundred milliseconds with the PR223EF these are considerably reduced.
This performance is made possible thanks to the EFDP (Early Fault Detection and Prevention) algorithm, which is able to detect the short-circuit at its onset, exploiting analysis of the trend of the
shunted current in relation to the current. The PR223EF release therefore offers two performances
simultaneously which, until today, were antithetic: selectivity and trip rapidity.
Thanks to extremely rapid detection and elimination of the short-circuit, the MCCs equipped with
this release are selective up to over 100 kA, and are not subject to any limits regarding the number
of hierarchical levels of the installation. Trip rapidity, together with just as rapid transmission of the
order to wait, allow a high number of circuit-breakers to be interlocked, making a global selectivity
chain in the installation: by using the PR223EF no limitation in topological terms is introduced, with
distances between interlocked circuit-breakers reaching up to 300 metres, thereby making the
protection system highly flexible.
Zone selectivity is carried out by means of an interlocking protocol (Interlocking, IL). The connection
is made by means of a simple screened telephone cable which connects the circuit-breakers fitted
with the PR223EF. In the case of a fault, the circuit-breaker immediately to the supply side sends a
locking signal to the hierarchically higher circuit-breaker by means of the bus and, before intervening,
checks that a simular locking signal has not been reached by the circuit-breakers on the load side.
The soundness of the system is controlled by a monitoring function of the interlock channel, guaranteeing the system a very high level of safety. All the protection functions can be programmed remotely
using the dialogue function present on the release or locally by means of the PR010/T which can be
connected to the serial port on the front of the PR223EF.
The release can be supplied from a 24 V DC auxiliary source or directly through the current transformers (self-supply). In the presence of an auxiliary power supply:
the device implements the L, S, EF and G protection functions;
if the EF is disabled by the user, function I is enabled
zone selectivity is implemented on the S, EF and G functions
If it is under self-supply conditions:
the release disables the EF, implementing the classic protection
functions which also characterise the PR222/DS: L, S, I and G
zone selectivity is not enabled.
Connection of the interlock and auxiliary power supply is made
by means of the X3 and X4 connectors located on the back of
the release.
ABB SACE
1/11
Signals
By means of
CB state
Dialogue
Type
open, closed, tripped
FDU, Dialogue,
PR010/T
Number of operations
Dialogue
When there is an auxiliary power supply, the PR223EF, fitted with the VM210 module and the FDU
unit, makes it possible to display the installation currents, voltages, powers and energy.
The PR223EF release is an integral part of the circuit-breaker and is therefore not interchangeable
with the other protection releases available on T4, T5 and on T6.
Apart from the above-mentioned technical advantages, use of circuit-breakers equipped with the
PR223EF release means obtaining significant simplification of selection of the circuit-breakers inside
the installation, which is only correlated with the current and breaking capacity. Furthermore, with
EFDP zone selectivity, it is possible to reduce the size of the circuit-breakers and optimise cable and
busbar sizing, with consequent reduction of plant costs.
PR223EF
LED signalling
the status of the
circuit-breaker
Socket for connection
of SACE PR010/T
test unit
1SDC210215F1002
1/12
ABB SACE
Protection functions
EF
(2)
I1=0.4...1xIn
step 0.01xIn
t = 318s(1)
step 0.5 s
I2=0.6...10xIn
step 0.1xIn
t= 0.050.5s
step 0.01 s
I3=1.5...12xIn(2)
step 0,1xIn
Istantaneous
25ms
I4=0.2...1xIn
step 0.01xIn
t = 0.10.8s
step 0.01s
Interlock
Zone selectivity interface with Emax releases
Application
Power supply
Operating frequency
Operating temperature
Storage temperature
Relative humidity
Electromagnetic compatibility (LF and HF)
Dialogue
Protocol
Physical means
Measurement functions
Currents
Voltages, powers, unbalanced phases, energies
(1)
Not excludable.
Enabled with Vaux and with self-supply
The top value is limited to 12 s with the following circuit-breakers: T4-320, T5-630.
The top value is limited to 10 In with the following circuit-breakers: T4-320, T5-630, T6-1000.
Current transformers
PR223EF
In [A]
T4
T5
T6
L
S
I
G
100
40100
601000
1501200
20100
160
64..160
961600
2401920
32...160
250
100250
1502500
3753000
50250
320
128320
1923200
4803200*
64320
400
630
800
1000
252630
6306300
9457560
126630
320800
8008000
12009600
160800
4001000
100010000
150012000
2001000
160400
2404000
6004800
80400
* For T5 4803840
ABB SACE
1/13
(AC) 50-60 Hz
(DC)
160
1100
3
690
500
8
800
3000
250
100200
3
690
500
8
800
3000
[A]
[A]
[No]
[V]
[V]
[kV]
[V]
[V]
N
65
36
30
25
6
S
85
50
45
30
7
H
100
70
55
36
8
L
120
85
75
50
10
N
50
36
25
20
5
S
85
50
40
30
8
[%Icu]
[%Icu]
[%Icu]
[%Icu]
[%Icu]
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
75% (70 kA)
75%
75%
75%
75%
75%
75%
75%
75%
50%
50% (27 kA)
50%
50%
50%
[kA]
[kA]
[kA]
[kA]
[kA]
[ms]
143
75.6
63
52.5
9.2
3
187
105
94.5
63
11.9
3
220
154
121
75.6
13.6
3
264
187
165
105
17
3
105
75.6
52.5
40
7.7
7
187
105
84
63
13.6
6
[kA]
[kA]
[kA]
[kA]
[kA]
IEC 60947-2
(MF up to In 12.5 A)
F-P
F-P
fixed
F - FC Cu - FC CuAl - EF ES - R - FC CuAl
F - FC Cu - FC CuAl - EF ES - R - FC CuAl
plug-in
F - FC Cu - FC CuAl - EF ES - R - FC CuAl
F - FC Cu - FC CuAl - EF ES - R - FC CuAl
DIN EN 50022
25000
240
8000
120
90
70
130
1.1
1.5
DIN EN 50022
25000
240
8000
120
105
70
150
1.5
2.7
withdrawable
fixed
plug-in
withdrawable
KEY TO TERMINALS
F = Front
EF = Front extended
ES = Front extended spread
FC Cu = Front for copper cables
FC CuAl = Front for copper-aluminium cables
R = Rear orientated
MC = Multicable
HR = Rear in horizontal flat bar
VR = Rear in vertical flat bar
1/14
Tmax T3
IEC 60947-2
Weight
Tmax T2
[No. operations]
[No. Hourly operations]
[No. operations]
[No. Hourly operations]
W [mm]
D [mm]
H [mm]
[kg]
[kg]
[kg]
F = Fixed circuit-breaker
P = Plug-in circuit-breaker
W = Withdrawable circuit-breaker
(*) Icw = 5 kA
75% for T5 630
50% for T5 630
(1)
(2)
ABB SACE
Tmax T4
Tmax T5
Tmax T6
800
630
3
690
750
8
1000
3500
L
200
120
100
85
70
V
300
200
180
150
80
N
70
36
30
25
20
S
85
50
40
30
25
400, 630
320, 400, 630
3
690
750
8
1000
3500
H
100
70
65
50
40
L
200
120
100
85
70
V
300
200
180
150
80
N
70
36
30
25
20
S
85
50
45
35
22
H
100
70
50
50
25
L
200
100
80
65
30
100%
100%
100%
100%
100%(1)
100%
100%
100%
100%(1)
100%(2)
100%
100%
100%
100%(2)
100%(2)
100%
100%
100%
100%
75%
100%
100%
100%
100%
75%
100%
100%
100%
100%
75%
75%
75%
75%
75%
75%
N
70
36
30
25
20
S
85
50
40
30
25
250, 320
10320
3
690
750
8
1000
3500
H
100
70
65
50
40
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
154
75.6
63
52.5
40
5
187
105
84
63
52.5
5
220
154
143
105
84
5
A
IEC 60947-2
440
264
220
187
154
5
660
440
396
330
176
5
154
75.6
63
52.5
40
6
187
220
440
105
154
264
84
143
220
63
105
187
52.5
84
154
6
6
6
B (400 A)(*) - A (630 A)
IEC 60947-2
660
440
396
330
176
6
154
187
220
440
75.6
105
154
220
63
94.5
105
176
52.5
73.5
105
143
40
46.2
52.5
63
10
9
8
7
B (630 A - 800 A) - A (1000 A)
IEC 60947-2
F-P-W
F-P-W
F-W
F - FC Cu - FC CuAl - EF - ES - R- MC
F - FC Cu - FC CuAl - EF - ES - R
F - FC CuAl - EF - ES - R - RC
EF - ES - R - FC Cu - FC CuAl
EF - ES - R - FC Cu - FC CuAl
EF - ES - R - FC Cu - FC CuAl
20000
240
8000
120
105
103.5
205
2.35
3.6
3.85
EF - ES - R - FC Cu - FC CuAl
20000
120
7000
60
140
103.5
205
3.25
5.15
5.4
ABB SACE
EF - HR - VR
20000
120
5000
60
210
103.5
268
9.5
12.1
1/15
1
PR222MP
Protection R
Against motor block
Protection I
Against short-circuit with
instantaneous trip
Protection L
Against motor overload
Protection U
Against phase
current unbalance or
loss of phase
Class
Class of motor starting
according to the IEC
60947-4-1 Standards
Man/Elt
1SDC210005F1002
Release parametrisation
methods
Selection between:
- PT(1) temperature sensor input
- 1/0 generic input
Setting the back-up time
Setting the reset
following trip:
- manual
- automatic
(1)
1/16
A special input is available to connect a PTC temperature probe, inserted in the motor to be protected
ABB SACE
1
PR222MP - Electronic
overcurrent releases
Tmax T6
In [A]
T6 800 N,S,H,L
630
252630
I1 [A]
310 x I1
I5 [A]
37808190
I3 [A]
0.4 x I1
I6 [A]
ABB SACE
l1
l3
I5
t5
I6
t6
le
la
Ip
ta
tp
m
c
=
=
=
=
=
=
=
=
=
=
=
=
=
1/17
(AC) 50-60 Hz
Weight
fixed
KEY TO TERMINALS
F = Front
FC Cu = Front for copper cables
(*) Icw = 5 kA
F = Fixed circuit-breakers
Tmax T6
250
3
1000
8
1000
3500
400, 630
3
1000
8
1000
3500
[kA]
L
12
V(1)
20
L
12
V(1)
20
630, 800
3
1000
8
1000
3500
L
12
[kA]
12
12
10
10
[kA]
24
[No. operations]
[No. Hourly operations]
3 poles
W [mm]
D [mm]
H [mm]
3 poles
Tmax T5
[A]
[No]
[V]
[kV]
[V]
[V]
PR221DS-LS
PR221DS-I
PR222DS-LSI
PR222DS-LSIG
Interchangeability
Versions
Terminals fixed
Mechanical life
Tmax T4
40
24
40
B (400 A)(*) - A (630A)
IEC 60947-2
F
FC Cu
20000
120
140
103.5
205
3.25
IEC 60947-2
F
FC Cu
20000
240
105
103.5
205
2.35
(1)
24
B
IEC 60947-2
F
F-FC CuAl-R
20000
120
210
103.5
268
9.5
1/18
630
800
ABB SACE
Weight
fixed
KEY TO TERMINALS
F = Front
FC Cu = Front for copper cables
Tmax T4
Tmax T5
Tmax T6
[kA]
[kA]
250
4
1000
8
1000
3500
V(1)
20
40
400, 630
4
1000
8
1000
3500
V(1)
20
40
630, 800
4
1000
8
1000
3500
L
12
40
[kA]
12
12
[kA]
40
A
IEC 60947-2
F
FC Cu
20000
240
140
103.5
205
3.05
40
B (400 A)* - A (630 A)
IEC 60947-2
(up to 500 A)
F
FC Cu
20000
120
184
103.5
205
4.15
24
B
IEC 60947-2
F
F-FC CuAl-R
20000
120
280
103.5
268
12
[A]
[No]
[V]
[kV]
[V]
[V]
[No. operations]
[No. Hourly operations]
4 poles
W [mm]
D [mm]
H [mm]
4 poles
(1)
(*) Icw = 5 kA
F = Fixed circuit-breakers
I1= 0.71 x In
In [A]
630
800
400
500
31506300
40008000
T6
I3 = 510 x In [A]
I3 = 510 x In
ABB SACE
1/19
Switch-disconnectors
Electrical characteristics
The Tmax switch-disconnectors are derived from the corresponding circuit-breakers, of which they
keep their overall dimensions, versions, fixing systems and the possibility of mounting accessories unaltered. This version only differs from the circuit-breakers in the absence of the protection releases.
The switch-disconnectors are characterised by a rated voltage of 690 V in alternating current and
up to 750 V in direct current.
Tmax T1D
Traditional thermal current, Ith
Rated service current in category AC23, Ie
Poles
Rated service current, Ue
Rated impulse withstand voltage, Uimp
Rated insulation voltage, Ui
Test voltage at industrial frequency for 1 min.
Rated short-circuit making capacity, Icm
(AC) 50-60 Hz
(DC)
Weight
fixed
plu-in
withdrawable
160
125
3/4
690
500
8
800
3000
2.8
187
2
IEC 60947-3
F
FCCu - EF - FCCuAl
25000
120
76
102
130
70
0.9/1.2
[No. operations]
[No. Hourly operations]
W [mm]
W [mm]
H [mm]
D [mm]
[kg]
[kg]
[kg]
3 poles
4 poles
[A]
[A]
[Nr.]
[V]
[V]
[kV]
[V]
[V]
[kA]
[kA]
[kA]
3/4 poles
3/4 poles
3/4 poles
(1)
Icu [kA]
T6D 630
T6D 800
T6D 1000
N
36
36
T6 630
S
H
50
70
50
70
L
100
100
N
36
T6 800
S
H
50
70
L
100
36
50
100
70
N
36
T6 1000
S
H
50
70
L
100
36
50
100
70
Applications
They can be used as general sub-switchgear circuit-breakers, as switching and isolating parts for
lines, busbars or groups of apparatus, or as bus-ties. They can be part of general isolation devices
of groups of machines or of assemblies for switching and protecting a motor.
Isolation
The main function carried out by this apparatus consists of isolating the circuit they are inserted in.
Once they are open, the contacts are at a distance which prevents an arc striking, respecting the
prescriptions of the standards regarding isolation behaviour. The position of the operating lever corresponds with certainty to the one of the contacts (positive operation).
1/20
ABB SACE
Tmax T3D
Tmax T4D
Tmax T5D
Tmax T6D
250
200
3/4
690
500
8
800
3000
5.3
105
3.6
IEC 60947-3
F-P
F-FCCuAl-FCCu-EF-ES-R
25000
120
105
140
150
70
1.5/2
2.1/3.7
250/320
250/250(2)
3/4
690
750
8
800
3000
5,3
440
3.6
IEC 60947-3
F-P-W
F-FCCuAl-FCCu-EF-ES-R-MC-HR-VR
20000
120
105
140
205
103.5
2.35/3.05
3.6/4.65
3.85/4.9
400/630
400/400(3)
3/4
690
750
8
800
3000
11
440
6
IEC 60947-3
F-P-W
F-FCCuAl-FCCu-EF-ES-R-HR-VR
20000
120
140
184
205
103.5
3.25/4.15
5.15/6.65
5.4/6.9
630/800/1000
630/800/800(4)
3/4
690
750
8
1000
3500
30
440
15
IEC 60947-3
F-W
F-FC CuAl-EF-ES-R-RC
20000
120
210
280
103.5
268
9.5/12
12.1/15.1
Protection
Each switch-disconnector must be protected on the supply side by a coordinated device which
safeguards it against short-circuits. The coordination table given in the previous page indicates the
Tmax circuit-breaker which can carry out the protection function for each switch-disconnector. This
is always apparatus of a corresponding or smaller size than that of the switch-disconnector.
Making capacity
The making capacity Icm is a considerably important performance since a switch-disconnector must
be able to support the dynamic, thermal and current stresses which can occur during closing, up to
the short-circuit closing conditions.
Withstand in closed position
This identifies the capacity to keep the closed position for short-time overcurrents. It is a significant
parameter which qualifies the performances of these pieces of apparatus.
ABB SACE
1/21
Accessories
Index
Accessories in common with the other sizes in the Tmax family ......................................... 2/3
Versions and types ............................................................................................................... 2/3
Connection terminals ........................................................................................................... 2/4
Remote control ..................................................................................................................... 2/7
Operating mechanisms and locks ........................................................................................ 2/8
Accessories for electronic releases ...................................................................................... 2/9
ABB SACE
2/1
Accessories
The high level of standardisation characterising the Tmax range also covers the accessories of the
T6 size: most of the accessories, which can be mounted on T6, are the same ones available for the
smaller sizes. The connection terminals, which can be mounted on T6, are the same as those available on S6, except for the rear terminals, which abandon their cylindrical shape to become uniform
with T4-T5 and therefore be orientated flat. Furthermore specific accessories for this size complete
the range of accessories for T6.
1SDC210217F1002
2/2
ABB SACE
Abbreviation
SOR - SOR-C
PS-SOR - PS-SOR-C
UVR - UVR-C
UVD
AUX-C
AUX
AUX-SA
AUP
AUE
ADP
FLD
RCQ
PR010/T
PR021/K
FBP
ATS
T1
T2
T3
T4
T5
T6
Caption: For further in-depth technical information about these accessories, please see the Tmax - Low voltage moulded-case circuit-breakers up to 630A technical catalogue.
1SDC210218F1002
1SDC210219F1002
T6 630
T6 800
T6 1000
F
Fixed
ABB SACE
2/3
Accessories
Connection terminals
The circuit-breaker Tmax T6 in the basic version is supplied with front terminals (F). Furthermore,
different types of terminals are available which can be combined with each other in various ways (top
of one type, bottom of a different type), allowing the circuit-breaker to be connected to the plant in
the most suitable way in relation to installation requirements.
A distinction can be made between:
front terminals, which allow cables or busbars to be connected acting directing from the front
of the circuit-breaker
rear orientated terminals, which allow installation of the circuit-breakers in switchgear with rear
access to both the cable and busbar connections.
Terminals are available for direct connection of bare copper or aluminium cables and terminals for
connection of busbars or cables terminated with cable terminals. The fixed parts can have EF, HR
or VR terminals.
For each type of terminal, the information needed to make the connections is summarised in the table
below. For connection with bare cables, the minimum and maximum cable cross-sections which can
be tightened in the terminals are indicated, as well as the types of cables (rigid or flexible) and the
diameter of the terminal. Flat terminals of different dimensions and composition are recommended
for connections with busbars. The torque values to apply to the terminal tightening screws of the
terminals for cables and to the screws used to connect the busbars to the flat terminals.
The circuit-breakers can be ordered complete with the required terminals (pre-assembled in the
factory), associating the standard version code of the circuit-breaker with those of the terminal kits,
or the terminals can be ordered individually in packs of 3 - 4 - 6 or 8 pieces.
To receive the circuit-breaker with mixed terminals, the two terminal half-kits must be specified in
the order, indicating the one to be mounted at the top as the first half-kit and, after that, the one to
be mounted at the bottom. Moreover, it is very important to remember that if the top terminals are
the same as the bottom ones, it is compulsory to order the complete kit (6 or 8 pieces) and not the
two half-kits.
To complete the range, high and low terminal covers, protections for high terminal covers and phase
separator partitions are also available.
All the terminals which can be mounted on T6, with the sole exception of the rear terminals and of
the front terminals, are the same as those mounted on Isomax S6.
T6 630
T6 800
T6 1000
EF
ES
FC CuAl FC CuAl
Front
terminals
Front
extended
terminals
Front
extended
spread
terminals
Front
terminals
for CuAl
cables
F (2)
F (2)
F-W
F-W
F
F
Front
terminals
for CuAl
cables(1)
F
F(3)
RC
HR
VR
Rear
terminals for
CuAl cables
Rear
terminals
Rear
flat
horizontal
terminals
Rear
flat
vertical
terminals
F
F
F
F
F(3)
W
W
W
W
(1)
House externally
Standard supply
The T6 1000 A circuit-breaker must mount a type of terminals among those shown in the table
F = Fixed
W = Withdrawable
(2)
(3)
2/4
ABB SACE
Terminals
1SDC210015F1002
Front terminals - F
Version
Pieces
F
F
2
2
T6 630
T6 800
40
12
5
2x7
50
12
5
2x7
Tightening (Nm)
9
9
Terminal covers
top
bottom
R
R
R
R
Phase separators
R
R
2
1SDC210016F1002
(2)
Pieces
F-W
F-W
2
2
Busbars (mm)
L
H
40
5
11(2)
50
5
14
40
11(2)
50
14
Tightening (Nm)
A
B (1)
9
18
9
30
Terminal covers
top
bottom
Phase separators
Tightening (Nm)
A
B(1)
9
30
9
30
9
30
Terminal covers
top
bottom
Phase separators
R (2)
R (2)
1SDC210017F1002
(1)
Version
Version
Pieces
F
F
F
1
1
1
Busbars (mm)
Cable terminal (mm)
L
H
80
5
3 x 13
3 x 45
13
80
8
3 x 13
3 x 45
13
80
8
3 x 13
3 x 45
13
ABB SACE
2/5
Accessories
Connection terminals
1SDC210228F1002
Allow bare copper or aluminium cables to be connected directly to the circuit-breaker (solid aluminium cables cannot be used)
Type
Mounting
Version
Pieces
T6 630
T6 800
T6 1000
standard
external
external
F
F
F
2
3
4
Cable (mm2)
rigid
2 x 240
3 x 185
4 x 150
clamp (mm)
Terminal covers
top
bottom
R
21.5
19
19
Phase separators
R
1SDC210021F1002
Tightening (Nm)
A
B
5
31
9
43
9
43
Allow busbars or cables with cable terminal to be connected on the rear. They can be installed in 4 different positions to facilitate cable/busbar connection
Type
T6 630
T6 800
T6 1000
Pieces
F
F
F
L
40
50
50
2
2
2
Busbars (mm)
H
5
5
6
14
14
14
Tightening (Nm)
A
B(1)
18
30
18
30
18
30
Terminal covers
top
bottom
Phase separators
1SDC210022F1002
1SDC210022F1002
(1)
Version
Pieces
F
F
2
3
T6 630
T6 800
Tightening (Nm)
A
B
9
43
9
31
clamp (mm)
21
17.5
Terminal covers
top
bottom
S
1SDC210229F1002
Type
Allow busbars or cables with cable terminal to be connected on the rear. There are rear horizontal or vertical terminals
Type
T6 630
T6 800
(1)
Version
W
W
Pieces
2
2
L
40
50
Busbars (mm)
H
5
14
5
14
40
14
50
14
Tightening (Nm)
B(1)
30
30
Phase separators
2/6
ABB SACE
Accessories
Remote control
With the stored energy motor operator, it is possible to control both opening and closing of the
circuit-breaker on which it is installed. During opening of the circuit-breaker, the spring system is
rechargedautomatically: the stored energy is exploited in this way to close the circuit-breaker.
The motor operator is always supplied with socket-plug connectors with 1m long cables and is
always fitted with a padlock. The connectors, once inserted in the special slot on the left-hand side
of the circuit-breaker, extend in relation to the outline of the circuit-breaker itself.
The motor operator can be fitted both with a key lock in the open position (with the same MOL-S keys
for groups of circuit-breakers or
different MOL-D keys) and with
MOE and MOE-E
an MOL-M key lock against
Tmax T6
manual operation: in the former
Rated voltage, Un
AC [V]
DC [V]
case, the lock in the open po
24
4860
sition is both of electrical and
110125
110125
mechanical type, in the latter
220250
220250
case, only of mechanical type,
380
1SDC210221F1002
1SDC210220F1002
ABB SACE
2/7
Accessories
Operating mechanisms and locks
1SDC210222F1002
The Tmax T6 circuit-breaker can be fitted with a rotary handle operating mechanism. The technical
characteristics are the same as the rotary operating mechanisms for T4-T5, with exception of the
handle of the direct rotary handle operating mechanism which is distinguished by an articulated joint
so that the switchgear door can be opened in the case of an emergency.
Locks
The following table indicates the locks available on T6, T5 and T4 (common accessories).
T4
FDL
KLF-D and KLF-S
KLF-FP and PLL FP
MOL-D and MOL-S
MOL-M
T5
T6
Caption: For further in-depth technical information about these accessories, please see the Tmax - Low voltage moulded-case circuit-breakers
up to 630A technical catalogue.
2/8
1SDC210028F1002
1SDC210026F1002
1SDC210025F1002
1SDC210027F1002
This allows installation of two circuit-breakers on a single support and, by means of special lever
mechanisms, makes the mechanically interdependent. It prevents operation in parallel of two power
supply sources (e.g.: normal - emergency). It consists of a kit of levers and assembly accessories and
of a metal support. The circuit-breakers and any control accessories must be ordered separately. The
mechanical interlock available for T6 in the version for side-by-side circuit-breakers and for stacked
circuit-breakers is the same as the one used to interlock Isomax S6.
To be able to receive the circuit-breakers already mounted on the interlock plate, the code
1SDA050093R1 must be specified as the accessory of the second circuit-breaker (or fixed part)
which is to be interlocked.
ABB SACE
Accessories
Accessories for electronic releases
Connectors
The X3 and X4 connectors allow connection of the electronic with units or components of external
plants. In fact, they are used to make the alarm signal of L, connection of the external neutral, connection to the PR020/K signalling unit, to the PR212/CI contactor control unit or to the PTC motor
temperature sensor, available outside, and allow two-way communication between the circuit-breaker
fitted with dialogue and the outside or vice versa.
Both the connectors are available both for fixed version circuit-breakers and for plug-in or withdrawable version circuit-breakers.
Connector
Function
Release
X3
PR021/K
L alarm signalling
Auxiliary power supply
IM210
EP 010
External neutral
VM210
IM210
PR212/CI
PTC
X4
ext. CT
T6 630
[A]
630
T6 800
[A]
800
T6 1000
[A]
1000
ABB SACE
2/9
Accessories
Accessories for electronic releases
VM210
The VM210 accessory combined with the PR223EF and PR223DS protection devices is able to
provide the various measurements of the electrical values of the installation.
1SDC210223F1002
Values
24 V DC20%
-25 C+70 C
5%...98%
Certifications
Product
Electromagnetic compatibility
IEC 60068
IEC 61010-1
The VM210 device is able to provide the measurements of up to 5 electronic releases. The connection distance between the module and the release is a maximum of 15 m. Anyway for distances over
1 m a screened multi-core connection cable must be used.
Measurements
With N
Without N
Apparent powers
Stot
Active powers
Ptot
Reactive powers
Qtot
Power factors
cos
cos
Active energy
Reactive energy
Apparent energy
Frequency
Peak factors
Circuit-breaker state
Open/closed
Protection function parameters
Remote / local control
(1)
2/10
only PR223EF
ABB SACE
IM210
The IM210 interlock module guarantees extension of the zone selectivity from the PR223EF of the
Tmax range to the Emax PR122 and PR123 electronic releases. The device makes interfacing
between protocol IL of the PR223EF and the zone selectivity ZS of the PR122 and PR123 devices
possible. In particular:
2
ZS-G
ZS-S (S,EF)
ZS-S (S,EF)
ZS-G
IM210
MONITOR
IL (S,G,EF)
Values
24 V DC 20%
-25 C+70 C
5%...98%
Certifications
Environmental tests
Electromagnetic compatibility
IEC 60068
IEC 61000
SD-TestBus 2
SD-TestBus 2 is the ABB SACE commissioning and diagnostic software for all Modbus RTU devices.
It can be used during system startup, or to troubleshoot an installed network.
SD-TestBus 2 automatically scans the RS-485 bus, detects all connected devices and checks
their communication settings. All possible combination of device address, parity and baud rate are
checked.
ABB SACE
2/11
Index
Characteristic curves
Trip curves for distribution
Circuit-breakers with thermomagnetic releases ................................................................... 3/2
Circuit-breakers with electronic releases ............................................................................ 3/3
Trip curves for advanced zone selectivity
Circuit-breakers with electronic release PR223EF ............................................................... 3/6
Trip curves for motor protection
Circuit-breakers with electronic release PR221DS-I ............................................................ 3/10
Circuit-breakers with electronic release PR222MP .............................................................. 3/11
Specific let-through energy curves
230 V .................................................................................................................................... 3/13
400-440 V ............................................................................................................................. 3/13
500 V .................................................................................................................................... 3/14
690 V .................................................................................................................................... 3/14
Current-limiting curves
230 V .................................................................................................................................... 3/15
400-440 V ............................................................................................................................. 3/15
500 V .................................................................................................................................... 3/16
690 V .................................................................................................................................... 3/16
Technical information
Temperature performances
Circuit-breakers with magnetic only, electronic releases and switch-disconnectors ......... 3/17
Circuit-breakers with thermomagnetic releases .................................................................. 3/19
Dissipated powers ............................................................................................................... 3/19
Special applications
Use of the apparatus at 16 2/3Hz ....................................................................................... 3/20
Use of the apparatus in direct current ................................................................................. 3/20
Application example of advanced zone selectivity with PR223EF ...................................... 3/21
ABB SACE
3/1
t [s]
104
TMA
In = 630 A
103
102
10
10-1
10-1
T6 800
t [s]
1,05
10
102
x I1
1SDC210031F1002
10-2
104
TMA
In = 800 A
103
102
10
10-1
10-1
3/2
1,05
10
102
x I1
1SDC210032F1002
10-2
ABB SACE
t [s]
104
0,4-0,44-0,48-0,52-0,56-0,6-0,64-0,68-0,72-0,76-0,8-0,84-0,88-0,92-0,96-1
Functions L-I
0,4
103
1,5
2 2,5
8 8,5
9 10
102
10
102
1
T6 630
T6 800
T6 1000
10-1
10-2
1SDC210033F1002
3
10-3
10-1
T6 630/800/1000
t [s]
10
104
10
I [kA]
0,4-0,44-0,48-0,52-0,56-0,60-0,64-0,680,72-0,76-0,80-0,84-0,88-0,92-0,96-1
PR221DS
1
0,4
Functions L-S
x In
103
1,5
2
2,5
3
102
3,5
4,5
10
102
1
T6 630
T6 800
T6 1000
10-1
10-3
10-1
10
x In
ABB SACE
10
I [kA]
1SDC210034F1002
10-2
3/3
T6 630/800/1000
t [s]
PR222DS/P
PR222DS/PD and
PR223DS
104
0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,981
0,4
103
Functions L-S-I
(I2t const = ON)
5,5
2,5 3
6,5
4,5
0,6
102
7
5
7,5
8
Note
9
9,5
1,5
10
10,5
12
102
I2t ON
T6 630
T6 800
T6 1000
10-1
10-2
1SDC210035F1002
3
10-3
10-1
T6 630/800/1000
PR222DS/P
PR222DS/PD and
PR223DS
t [s]
10
104
x In
0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,981
0,4
103
Functions L-S-I
(I2t const = OFF)
2,5
4 4,5
5,5
6,5
102
7,5
8
Note
(1) The electronic settings are available
for the PR223DS.
(2) For T6 In = 1000 A
with PR222, the available electronic
settings for t1 are: 3s, 6s, 12s and
18s.
(3) For T6 In = 1000 A
I3max = 10 x In.
10
I [kA]
1,2
0,6
9
9,5
1,5
10
10,5
12
102
I2t OFF
T6 630
T6 800
T6 1000
10-1
10-3
10-1
10
1
x In
3/4
10
I [kA]
1SDC210036F1002
10-2
ABB SACE
T6 630/800/1000
PR222DS/P
PR222DS/PD and
PR223DS
Functions G
t [s]
104
0,2 0,25
103
0,8
102
10
10-1
10-2
10-3
10-1
ABB SACE
10
102
x In
1SDC210037F1002
3/5
PR223EF
t [s]
104
0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,981
T4 250/320
T5 400/630
0,4
103
Functions L-S-I
(I2t const = ON)
0,6
102
With self-supply
10
Note
1,5
12
10
102
I2t ON
T4
10-1
T5 400
T5 630
10-2
10-3
10-1
PR223EF
t [s]
104
With self-supply
0,4
103
102
10
Note
For all the CT sizes t1 = 18s, except
with 320 A CT (T4) and 630 A (T5)
where t1 = 12s.
For T4 In = 320 A and T5 In = 630 A
I3 max = 10 x In.
10
I [kA]
x In
0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,981
T4 250/320
T5 400/630
Functions L-S-I
(I2t const = OFF)
10
1SDC210038F1002
1,5
0,6
12
10
102
I2t OFF
T4
T5 400
10-1
T5 630
10-3
10-1
10
x In
3/6
10
I [kA]
1SDC210039F1002
10-2
ABB SACE
T6 630/800/1000
t [s]
104
0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,981
PR223EF
0,4
103
Functions L-S-I
(I2t const = ON)
0,6
102
With self-supply
10
Note
1,5
12
10
102
I2t ON
T6 630
10-1
T6 800-1000
10-2
10-1
T6 630/800/1000
t [s]
104
0,4
With self-supply
10
I [kA]
103
102
10
Note
For T6 In = 1000 A I3 max = 10 x In.
x In
0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,981
PR223EF
Functions L-S-I
(I2t const = OFF)
10
1SDC210210F1002
3
10-3
1,5
0,6
12
10
102
I2t OFF
T6 630
T6 800-1000
10-1
10-3
10-1
10
1
x In
ABB SACE
10
I [kA]
1SDC210211F1002
10-2
3/7
PR223EF
t [s]
104
T4 250/320
T5 400/630
T6 630/800/1000
103
Functions L-S-I
(I2t const = ON)
102
0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,981
0,4
0,6
10
With auxiliary
power supply
12
10
Note
For all the CT sizes t1 = 18s, except
with 320 A CT (T4) and 630 A (T5)
where t1 = 12s.
For T4 In = 320 A and T5 In = 630 A
I3 max = 10 x In.
I2t ON
1
10-1
10-2
10-3
10-1
10 2
x In [kA]
10
1SDC210040F1002
3
PR223EF
t [s]
104
T4 250/320
T5 400/630
T6 630/800/1000
103
Functions L-S-I
(I2t const = OFF)
102
0,4-0,42-0,44-0,46-0,48-0,5-0,52-0,54-0,56-0,58-0,6-0,62-0,64-0,66-0,680,7-0,72-0,74-0,76-0,78-0,8-0,82-0,84-0,86-0,88-0,9-0,92-0,94-0,96-0,981
0,4
0,6
10
With auxiliary
power supply
12
10
Note
For all the CT sizes t1 = 18s, except
with 320 A CT (T4) and 630 A (T5)
where t1 = 12s.
For T4 In = 320 A and T5 In = 630 A
I3 max = 10 x In.
I2t ON
1
10-1
10-3
10-1
3/8
10
10 2
x In [kA]
1SDC210041F1002
10-2
ABB SACE
PR223EF
T4 250/320
T5 400/630
T6 630/800/1000
t [s]
104
0,2...1
0,2
103
Function G
102
10
10-1
10-2
10-1
ABB SACE
10
102
x In
1SDC210042F1002
3
10-3
3/9
104
PR221DS-I
Function I
103
1,5
2 2,5 3
3,5
T6 630-800
102
8,5
T6 1000
9
10
10
102
1
10-1
T6 630
10-2
T6 800-1000
10-3
10-1
3/10
10
x In
10
I [kA]
1SDC210043F1002
ABB SACE
t [s]
105
PR222MP
hot
Function L
(hot and cold intervention)
cold
104
103
102
10A
10
30
20
10
10A
30
20
10
10A
10-1
T6 800
t [s]
1,05
10
102
x I1
1SDC210044F1002
10-1
105
PR222MP
hot
Function L
(hot intervention with 1 or
2 phases supplied)
104
103
102
10A
10
30
20
10
10A
10-1
ABB SACE
1,05
10
102
x I1
1SDC210045F1002
10-1
3/11
t [s]
105
PR222MP
U function
Functions R-U
R function
104
103
102
4
5
6
7
8
10
10
10
7
4
10-1
T6 800
t [s]
1,05
10
102
x I1
1SDC210046F1002
10-1
103
PR222MP
13
12
Function I
11
102
10
9
8
10
6
10-1
10-2
10-1
3/12
1,05
10
102
x In
1SDC210047F1002
10-3
ABB SACE
T6 630/800/1000
230 V
102
T6 800-1000
10
T6 630
10
T6 630/800/1000
10
102
103
Irms [kA]
1SDC210048F1002
3
-1
400-440 V
102
T6 800-1000
T6 630
10
10-1
1
ABB SACE
10
102
103
Irms [kA]
1SDC210049F1002
3/13
T6 630/800/1000
2
I 2t [(kA) 2s] 10
500 V
T6 800-1000
T6 630
10
10-1
1
T6 630/800/1000
102
Irms [kA]
10
1SDC210050F1002
3
I2t [(kA)2s] 103
690 V
102
T6 800-1000
10
T6 630
10-1
1
3/14
10
102
103
Irms [kA]
1SDC210051F1002
ABB SACE
Current-limiting curves
T6 630/800/1000
Ip [kA]
230 V
102
T6 800-1000
T6 630
10
T6 630/800/1000
10
102
103
Irms [kA]
1SDC210052F1002
3
Ip [kA]
400-440 V
102
T6 800-1000
T6 630
ABB SACE
10
102
103
Irms [kA]
1SDC210053F1002
10
3/15
Current-limiting curves
T6 630/800/1000
Ip [kA] 102
T6 800-1000
500 V
T6 630
10
1
1
T6 630/800/1000
102
Irms [kA]
10
1SDC210054F1002
3
Ip [kA]
690 V
102
T6 800-1000
T6 630
3/16
10
102
103
Irms [kA]
1SDC210055F1002
10
ABB SACE
Temperature performances
Circuit-breakers with magnetic only, electronic releases
and switch-disconnectors
T6 630 and T6D 630
Fixed
up to 40 C
Imax [A]
I1
50 C
Imax [A]
I1
60 C
Imax [A]
I1
70 C
Imax [A]
I1
630
630
630
598.5
0.95
FC
630
630
598.5
0.95
567
0.9
R (HR-VR)
630
630
567
0.9
504
0.8
R = Rear terminals
FC
1SDC210056F1002
R (HR-VR)
up to 40 C
Imax [A]
I1
50 C
Imax [A]
I1
60 C
Imax [A]
I1
70 C
Imax [A]
I1
EF
630
630
598.5
0.95
567
0.9
VR
630
630
598.5
0.95
567
0.9
HR
630
598.5
0.95
567
0.9
504
0.8
EF-VR
1SDC210057F1002
HR
ABB SACE
3/17
Temperature performances
Circuit-breakers with magnetic only, electronic releases
and switch-disconnectors
T6 800 and T6D 800
Fixed
up to 40 C
Imax [A]
I1
50 C
Imax [A]
I1
60 C
Imax [A]
I1
70 C
Imax [A]
I1
800
800
800
760
0.95
FC
800
800
760
0.95
720
0.9
R (HR-VR)
800
800
720
0.9
640
0.8
R = Rear terminals
FC
R (HR-VR)
R
1SDC210058F1002
3
T6 800 and T6D 800
Withdrawable
up to 40 C
Imax [A]
I1
50 C
Imax [A]
I1
60 C
Imax [A]
I1
70 C
Imax [A]
I1
EF
800
800
760
0.95
720
0.9
VR
800
800
760
0.95
720
0.9
HR
800
760
0.95
720
0.9
640
0.8
EF-VR
1SDC210059F1002
HR
3/18
ABB SACE
up to 40 C
Imax [A]
I1
50 C
Imax [A]
I1
60 C
Imax [A]
I1
70 C
Imax [A]
I1
FC
1000
1000
913
0.91
817
0.82
R (HR)
1000
926
0.93
845
0.85
756
0.76
R (VR)
1000
961
0.96
877
0.88
784
0.78
1100
1000
FC
R (VR)
900
R (HR)
ES
35
40
45
50
55
60
65
70
1SDC210209F1002
10 C
MIN MAX
520 740
685 965
20 C
MIN MAX
493 705
640 905
30 C
MIN MAX
462 660
605 855
40 C
MIN MAX
441 630
560 800
50 C
MIN MAX
405 580
520 740
60 C
MIN MAX
380 540
470 670
70 C
MIN MAX
350 500
420 610
Dissipated powers
Power [W/pole]
TMA
PR221-222-223
ABB SACE
T6
In [A]
630
800
630
800
1000
F
30.6
31
30
32
50
W
30
39.6
38.3
41.6
3/19
Special applications
Caption
For further information on the electrical circuit
diagrams, please see the Tmax - Low voltage
moulded-case circuit-breakers up to 630 A
technical catalogue.
Wiring
diagram
A
A
B-C
D
36 50 70 100
20 35 50 70
16 20 36 50
- 40
Trip thresholds
The thermal threshold of the circuit-breaker is the same as for the normal version. For the magnetic threshold, a correction coefficient must
be used on the protection thresholds as indicated in the table:
Circuit-breaker
T6
Diagram A
Diagram B-C
Diagram D
0.9
0.9
0.9
3/20
Circuit-breaker
T6
0.9
0.9
Diagram F
0.9
ABB SACE
t 1E4s
2
Vaux
1E3s
100s
L
1
10s
1s
S
0.1s
I
2
1E-2s
EF
EF
0.1 kA
1 kA
10 kA
Iu
ABB SACE
3/21
Wiring diagrams
Index
Wiring diagrams
Information for reading - Circuit-breakers ............................................................................ 4/2
Electrical circuit diagrams of the Tmax T6 circuit-breakers ................................................. 4/3
Electrical accessories for Tmax T6 ...................................................................................... 4/4
ABB SACE
4/1
Wiring diagrams
Information for reading - Circuit-breakers
Caption
*
A1
A2
A4
H
K51
=
=
=
=
=
=
=
M
Q
R
S1, S2
S3
K51/18
S51/S
S751I/13
=
=
=
=
=
=
=
=
SC
SC3
SO
SO3
SY
=
=
=
=
=
TI
TI/L1
TI/L2
TI/L3
TI/N
W1
W2
W3
X11
X3,X4
=
=
=
=
=
=
=
=
=
=
XA
XA8
=
=
XF
X0
XV
YO1
=
=
=
=
Description of figures
Fig. 11
Fig. 12
Fig. 32
Fig. 39
Fig. 40
4/2
Wiring diagrams
Electrical circuit diagrams of the Tmax T6 circuit-breakers
with PR223
PR223DS
or PR223EF
1SDC210061F1002
1SDC210060F1002
State of operation
PR223DS
or PR223EF
Fixed version three-pole circuit-breaker with current transformer on neutral conductor, external to circuit-breaker
1SDC210061F1002
PR223DS
or PR223EF
Caption
For the circuit diagrams of T6 with PR221,
PR222 and PR222MP, please see the diagrams on the Tmax - Low voltage mouldedcase circuit-breakers up to 630 A technical
catalogue.
ABB SACE
4/3
Wiring diagrams
Electrical accessories for Tmax T6
1SDC210062F1002
Remote control
L2
L3
1SDC210063F1002
4/4
ABB SACE
L1
L2
L3
1SDC210063F1002
Caption
ABB SACE
4/5
Overall dimensions
Index
Overall dimensions
Tmax T6 - Fixed circuit-breaker ............................................................................................. 5/2
Tmax T6 - Terminals ............................................................................................................... 5/4
Tmax T6 - Withdrawable circuit-breaker ................................................................................ 5/7
Tmax T6 - Terminals ............................................................................................................... 5/8
Accessories for Tmax T6 ........................................................................................................ 5/9
Distances to be respected ................................................................................................... 5/14
ABB SACE
5/1
Overall dimensions
Tmax T6
Fixed circuit-breaker
210 (3P)
70
105
70
70
2.7
134
115
103.5
140
= =
5.5
280 (4P)
62.25
66.75
142
= =
107
1SDC210067F1002
1SDC210066F1002
149
= =
152
=
138
107
159
116
77.75
1SDC210065F1002
1SDC210064F1002
268
105
2.7
1SDC210068F1002
Fixing on sheet
61.25
Caption
140
35
118.5
5.5 - M5
3 POLES
5/2
1SDC210070F1002
1SDC210069F1002
237
237
118.5
5.5 - M5
4 POLES
ABB SACE
R 18
150.5
630 A (4 POLES)
140
35
70
= =
85.75
241.5
1SDC210075F1002
R 21.5
150.5
118.5
301
237
1SDC210074F1002
171.5
150.5
5.5 - M5
118.5
301
237
84
238
630 A (3 POLES)
R 21.5
1SDC210073F1002
301
118.5
150.5
1SDC210072F1002
168
237
301
237
R 18
5.5 - M5
140
35
5.5 - M5
118.5
5.5 - M5
70
= =
ABB SACE
5/3
Overall dimensions
Tmax T6
Terminals
Front - F
MAX 40
MIN5 MAX10
1SDC210077F1002
120.5
18 MIN
MAX 12
23
0.1
1SDC210076F1002
22.5
6.5
70
45.7
28
70
1SDC210079F1002
120.5
21.5
1SDC210078F1002
134
20.25
630 A
70
70
59
20
19
1SDC210081F1002
120.5
1SDC210080F1002
134
39
25.5
800 A
70
70
59
26
19
1SDC210231F1002
120. 5
1SDC210230F1002
134
39
26
1000 A
5/4
ABB SACE
Front extended - EF
70
70
70
40
36.5
1SDC210083F1002
167.5
1SDC210082F1002
134
48.5
11
630 A
70
70
70
50
33.5
1SDC210085F1002
162.5
1SDC210084F1002
134
48.5
14
800 A
116
116
88
116
88
45
45
90
88
45
23
45
116
116
88
23
45
90
50
13
13
4 POLES
1SDC210088F1002
1SDC210087F1002
134
1SDC210086F1002
134
230.5
116.5
116.5
3 POLES
Caption
1
ABB SACE
5/5
Overall dimensions
Tmax T6
Terminals
Rear for copper cables Cu/Al - RC CuAl
23.1
1SDC210090F1002
1SDC210089F1002
147
28
134
21.5
48.1
70
120.5
70
39.5
70
630 A
48.1
70
1SDC210092F1002
147
1SDC210091F1002
134
41
17.5
23.1
137.5
120.5
70
39.5
70
800 A
Rear - R
280 (4P)
210 (3P)
8
70
70
70
33
1SDC210093F1002
53
1SDC210094F1002
120.5
73
14
1SDC210095F1002
53
3-4 POLES
1
53
70
8
73
1SDC210097F1002
1SDC210096F1002
14
120.5
Caption
1
70
33
70
3-4 POLES
5/6
ABB SACE
Withdrawable
4
70
77
70
273
Moving part
145
208
70
167
190.5
196
35.5
123.5
1SDC210099F1002
1SDC210098F1002
Fixed part
140
84.5
280 (4P)
210 (3P)
isolating
27.5 corsa
di distance
sezionamento
3
144.75
Caption
1SDC210100F1002
Fixing on sheet
295
circuit-breaker
136.5
193.5
14
96.5
18
1SDC210102F1002
148.5
= =
32
18.5
150
89.5
1SDC210101F1002
100.25
173
210
75.25
122
R min. 200
140
R2
8.5 - M8
107
284
3 POLES
ABB SACE
1SDC210104F1002
144
77.5
214
120
120
8.5 - M8
1SDC210103F1002
144
77.5
77.5
77.5
R2
4 POLES
5/7
Overall dimensions
Tmax T6
Terminals
Front extended - EF
70
70
70
3
20
40
172.5
14
1SDC210106F1002
1SDC210105F1002
31
10
1SDC210109F1002
14
1SDC210108F1002
1SDC210107F1002
70
40
20
10
70
3-4 POLES
20
70
70
70
1SDC210112F1002
1SDC210111F1002
14
1SDC210110F1002
40
10
3-4 POLI
5/8
ABB SACE
Overall dimensions
Accessories for Tmax T6
Fixed version
Caption
Transmission unit
5.5
103.5
5.5
85..500
25
42.5
82
105.5
25
1SDC210113F1002
2.7
2.7
1SDC210114F1002
5.5
2
3
41.5
42.5
1SDC210115F1002
32
105
R 200 min.
41.5
1SDC210116F1002
50
45
50
Minimum rotation
radius for door
fulcrum
Caption
Det. A
33
5
3
140.5
2.7
2.7
41.5
R min. 200
With flange
152
173
100.25
142
85.5
1SDC210120F1002
151
90
148.5
14
96.5
43
142
R min. 200
1SDC210121F1002
14
96.5
43
ABB SACE
1SDC210122F1002
5.5
1SDC210118F1002
5.5
1SDC210119F1002
140
5.5
190
146.5
103.5
42.5
84.5
140
1SDC210117F1002
Without flange
5/9
Overall dimensions
Accessories for Tmax T6
Fixed version
Caption
Overall dimensions with
cabled auxiliary contacts
mounted (only 3Q 1SY)
140
= =
5.5
191.5
5.5
1SDC210123F1002
5.5
142
= =
148,5
= =
142
71.25
R min. 200
1SDC210126F1002
151
75,75
1SDC210125F1002
173
86.5
152
= =
R min. 200
With flange
222
233
1SDC210127F1002
1SDC210124F1002
14 0
70
Motor operator
Without flange
140
35
3 POLES
5/10
1SDC210129F1002
1SDC210128F1002
237
237
118.5
118.5
5.5 -M5
4 POLES
ABB SACE
Caption
1
158
146.5
103.5
140
2.7
2.7
17
Det. A
140.5
1SDC210131F1002
1SDC210130F1002
140
84.5
43
43
14
Det. A
14
148.5
R min. 200
142
R min. 200
1SDC210135F1002
1SDC210134F1002
96.5
142
85.5
1SDC210133F1002
151
90
96.5
1SDC210132F1002
100.25
173
152
=
5
140
35
3 POLES
ABB SACE
1SDC210137F1002
1SDC210136F1002
237
237
118.5
118.5
5.5 -M5
4 POLES
5/11
Overall dimensions
Accessories for Tmax T6
Withdrawable
version
Motor operator
isolating
27.5 corsa
di distance
sezionamento
241
1SDC210138F1002
1SDC210139F1002
14 0
70
37
140
3
281.5
18
122
R min. 200
1SDC210141F1002
148.5
= =
32
32.5
75.25
150
1SDC210140F1002
86.25
173
210
75.25
5/12
ABB SACE
140
1
2
1SDC210143F1002
Det. A
isolating
27.5 corsa
di distance
sezionamento
1SDC210119F1002
84.5
140
Caption
190.5
240
33
1SDC210142F1002
18
122
R min. 200
96.5
1SDC210145F1002
148.5
= =
32
14
18.5
150
89.5
43
1SDC210144F1002
100.25
173
210
75.25
ABB SACE
5/13
Overall dimensions
Distances to be respected
T6
(mm)
(mm)
(mm)
35(*)
25
20
(*)
1SDC210152F1002
4 poles
3 poles
4 poles
210
280
210
280
1SDC210153F1002
T6
3 poles
180
Caption
1
Insulated cable
Cable terminal
1SDC210154F1002
Note: The dimensions shown apply for operating voltage Ub up to 690 V. The
dimensions to be respected must be added to the maximum dimensions of the
various different versions of the circuit-breakers, including the terminals.
5/14
ABB SACE
Ordering codes
Index
General information .............................................................................................................. 6/2
Circuit-breaker T6 for power distribution ............................................................................. 6/3
Circuit-breaker T5 for power distribution ............................................................................. 6/7
Circuit-breaker T4 for power distribution ............................................................................. 6/9
Circuit-breakers for advanced zone selectivity .................................................................... 6/11
Circuit-breakers for motor protection................................................................................... 6/12
Circuit-breakers for applications up to 1000 V .................................................................... 6/13
Switch-disconnectors .......................................................................................................... 6/14
Fixed parts, conversion kits and interruption parts .............................................................. 6/15
Accessories .......................................................................................................................... 6/16
ABB SACE
6/1
Ordering codes
General information
F = Front
terminals
EF = Front
extended
terminals
FC CuAl =
Front
terminals for
Cu/Al cables
FC CuAl =
Front
terminals for
Cu/Al cables
ES = Front
extended
spread
terminals
R = Rear
terminals
(housed externally)
RC CuAl =
Rear
terminals for
Cu/Al cables
HR =
Rear flat
horizontal
terminals
I3
Magnetic trip
current [A]
Iu
Rated uninterrupted
current of the
circuitbreaker [A]
In
Icu
Rated ultimate
short-circuit
breaking capacity [A]
VR =
Rear flat
vertical
terminals
TMA
= Thermomagnetic
release with
adjustable thermal
and magnetic
threshold
6/2
ABB SACE
Ordering codes
Circuit-breaker T6 for power distribution
T6N 630
Fixed (F)
Iu (40 C) = 630
A - Icu (415 V) = 36 kA
F = Front terminals
In
Electronic release
T6N 630 F F
T6N 630 F F
T6N 630 F F
T6N 630 F F
T6N 630 F F
PR221DS-LS/I
PR221DS-I
PR222DS/P-LSI
PR222DS/P-LSIG
PR223DS
F = Front terminals
In
T6N 800
Fixed (F)
Iu (40 C) = 800
I3
31506300
060226
060227
060228
060229
060230
060231
060232
060233
060234
060235
1SDA..R1
3 poles
4 poles
060202
N = 50% N = 100%
060203
060210
A - Icu (415 V) = 36 kA
F = Front terminals
In
Electronic release
T6N 800 F F
T6N 800 F F
T6N 800 F F
T6N 800 F F
T6N 800 F F
PR221DS-LS/I
PR221DS-I
PR222DS/P-LSI
PR222DS/P-LSIG
PR223DS
F = Front terminals
In
T6N 1000
Fixed (F)
630
630
630
630
630
630
1SDA..R1
3 poles
4 poles
Iu (40 C) = 1000
800
800
800
800
800
800
I3
40008000
1SDA..R1
3 poles
4 poles
060268
060269
060270
060271
060272
060273
060274
060275
060276
060277
1SDA..R1
3 poles
4 poles
060214
N = 50% N = 100%
060215
060222
A - Icu (415 V) = 36 kA
F = Front terminals
In
1SDA..R1
3 poles
4 poles
Electronic release
T6N 1000 F F
PR221DS-LS/I
1000
060537
T6N 1000 F F
PR221DS-I
1000
060538
T6N 1000 F F
PR222DS/P-LSI
1000
060539
T6N 1000 F F
PR222DS/P-LSIG
1000
060540
T6N 1000 F F
PR223DS
1000
060541
Note: The circuit-breaker must be equipped with one of the connection terminals shown at page 2/4.
T6S 630
Fixed (F)
Iu (40 C) = 630
A - Icu (415 V) = 50 kA
F = Front terminals
Electronic release
T6S 630 F F
T6S 630 F F
T6S 630 F F
T6S 630 F F
T6S 630 F F
F = Front terminals
Thermomagnetic release - TMA
T6S 630 F F
ABB SACE
060542
060543
060544
060545
060546
In
PR221DS-LS/I
PR221DS-I
PR222DS/P-LSI
PR222DS/P-LSIG
PR223DS
In
630
630
630
630
630
630
I3
31506300
1SDA..R1
3 poles
4 poles
060236
060237
060238
060239
060240
060241
060242
060243
060244
060245
1SDA..R1
3 poles
4 poles
060204
N = 50% N = 100%
060205
060211
6/3
Ordering codes
Circuit-breaker T6 for power distribution
T6S 800
Fixed (F)
Iu (40 C) = 800
A - Icu (415 V) = 50 kA
F = Front terminals
In
Electronic release
T6S 800 F F
T6S 800 F F
T6S 800 F F
T6S 800 F F
T6S 800 F F
PR221DS-LS/I
PR221DS-I
PR222DS/P-LSI
PR222DS/P-LSIG
PR223DS
F = Front terminals
In
T6S 1000
Fixed (F)
Iu (40 C) = 1000
800
800
800
800
800
800
I3
40008000
1SDA..R1
3 poles
4 poles
060278
060279
060280
060281
060282
060283
060284
060285
060286
060287
1SDA..R1
3 poles
4 poles
060216
N = 50% N = 100%
060217
060223
A - Icu (415 V) = 50 kA
F = Front terminals
In
1SDA..R1
3 poles
4 poles
Electronic release
T6S 1000 F F
PR221DS-LS/I
1000
060547
T6S 1000 F F
PR221DS-I
1000
060548
T6S 1000 F F
PR222DS/P-LSI
1000
060552
T6S 1000 F F
PR222DS/P-LSIG
1000
060554
T6S 1000 F F
PR223DS
1000
060555
Note: The circuit-breaker must be equipped with one of the connection terminals shown at page 2/4.
T6H 630
Fixed (F)
Iu (40 C) = 630
A - Icu (415 V) = 70 kA
F = Front terminals
Electronic release
T6H 630 F F
T6H 630 F F
T6H 630 F F
T6H 630 F F
T6H 630 F F
Iu (40 C) = 800
In
630
630
630
630
630
630
I3
31506300
1SDA..R1
3 poles
4 poles
060246
060247
060248
060249
060250
060251
060252
060253
060254
060255
1SDA..R1
3 poles
4 poles
060206
N = 50% N = 100%
060207
060212
A - Icu (415 V) = 70 kA
F = Front terminals
Electronic release
T6H 800 F F
T6H 800 F F
T6H 800 F F
T6H 800 F F
T6H 800 F F
F = Front terminals
Thermomagnetic release - TMA
T6H 800 F F
6/4
In
PR221DS-LS/I
PR221DS-I
PR222DS/P-LSI
PR222DS/P-LSIG
PR223DS
F = Front terminals
T6H 800
Fixed (F)
060556
060557
060558
060559
060560
In
PR221DS-LS/I
PR221DS-I
PR222DS/P-LSI
PR222DS/P-LSIG
PR223DS
In
800
800
800
800
800
800
I3
40008000
1SDA..R1
3 poles
4 poles
060289
060290
060291
060292
060293
060294
060295
060296
060297
060298
1SDA..R1
3 poles
4 poles
060218
N = 50% N = 100%
060219
060224
ABB SACE
T6H 1000
Fixed (F)
Iu (40 C) = 1000
A - Icu (415 V) = 70 kA
F = Front terminals
In
1SDA..R1
3 poles
4 poles
Electronic release
T6H 1000 F F
PR221DS-LS/I
1000
060561
T6H 1000 F F
PR221DS-I
1000
060562
T6H 1000 F F
PR222DS/P-LSI
1000
060563
T6H 1000 F F
PR222DS/P-LSIG
1000
060564
T6H 1000 F F
PR223DS
1000
060565
Note: The circuit-breaker must be equipped with one of the connection terminals shown at page 2/4.
T6L 630
Fixed (F)
Iu (40 C) = 630
F = Front terminals
In
Electronic release
T6L 630 F F
T6L 630 F F
T6L 630 F F
T6L 630 F F
T6L 630 F F
PR221DS-LS/I
PR221DS-I
PR222DS/P-LSI
PR222DS/P-LSIG
PR223DS
F = Front terminals
In
T6L 800
Fixed (F)
Iu (40 C) = 800
630
630
630
630
630
630
I3
31506300
1SDA..R1
3 poles
4 poles
060256
060257
060258
060259
060260
060262
060263
060264
060265
060266
1SDA..R1
3 poles
4 poles
060208
N = 50% N = 100%
060209
060213
F = Front terminals
In
Electronic release
T6L 800 F F
T6L 800 F F
T6L 800 F F
T6L 800 F F
T6L 800 F F
PR221DS-LS/I
PR221DS-I
PR222DS/P-LSI
PR222DS/P-LSIG
PR223DS
F = Front terminals
In
T6L 1000
Fixed (F)
Iu (40 C) = 1000
F = Front terminals
800
800
800
800
800
800
I3
40008000
1SDA..R1
3 poles
4 poles
060299
060300
060301
060302
060303
060305
060306
060307
060308
060309
1SDA..R1
3 poles
4 poles
060220
N = 50% N = 100%
060221
060225
1SDA..R1
3 poles
4 poles
Electronic release
T6L 1000 F F
PR221DS-LS/I
1000
060574
T6L 1000 F F
PR221DS-I
1000
060575
T6L 1000 F F
PR222DS/P-LSI
1000
060576
T6L 1000 F F
PR222DS/P-LSIG
1000
060577
T6L 1000 F F
PR223DS
1000
060578
Note: The circuit-breaker must be equipped with one of the connection terminals shown at page 2/4.
ABB SACE
060566
060567
060568
060569
060573
060580
060581
060582
060583
060584
6/5
Ordering codes
Circuit-breaker T6 for power distribution
Releases for T6
F = Front terminals
In
1SDA..R1
3 poles
4 poles
Electronic release
PR221DS-LS/I
PR221DS-LS/I
PR221DS-LS/I
PR221DS-I
PR221DS-I
PR221DS-I
630
800
1000
630
800
1000
060351
060363
060596
060352
060364
060597
060357
060369
060602
060358
060370
060603
PR222DS/P-LSI
PR222DS/P-LSI
PR222DS/P-LSI
630
800
1000
060353
060365
060598
060359
060371
060604
PR222DS/P-LSIG
PR222DS/P-LSIG
PR222DS/P-LSIG
630
800
1000
060354
060366
060599
060360
060372
060605
PR223DS
PR223DS
PR223DS
630
800
1000
060376
060378
060608
060377
060379
060609
PR222DS/PD-LSI
PR222DS/PD-LSI
PR222DS/PD-LSI
630
800
1000
060355
060367
060600
060361
060373
060606
PR222DS/PD-LSIG
PR222DS/PD-LSIG
PR222DS/PD-LSIG
630
800
1000
060356
060368
060601
060362
060374
060607
F = Front terminals
Thermomagnetic release - TMA
TMA 630-6300
TMA 800-8000
In
630
800
I3
31506300
40008000
1SDA..R1
3 poles
4 poles
060347
060349
N = 50% N = 100%
060348
060472
060350
060473
6/6
ABB SACE
Ordering codes
Circuit-breaker T5 for power distribution
T5N 400
Fixed (F)
Iu (40 C) = 400
A - Icu (415 V) = 36 kA
F = Front terminals
Electronic release
T5N 400 F F
T5N 400 F F
T5N 630
Fixed (F)
Iu (40 C) = 630
PR223DS
PR223DS
Iu (40 C) = 400
Iu (40 C) = 630
Fixed (F)
PR223DS
PR223DS
PR223DS
ABB SACE
1SDA..R1
3 poles
4 poles
059533
059534
1SDA..R1
3 poles
4 poles
059535
059537
059536
059538
630
1SDA..R1
3 poles
4 poles
059539
059540
A - Icu (415 V) = 70 kA
In
PR223DS
PR223DS
320
400
1SDA..R1
3 poles
4 poles
059541
059543
059542
059544
A - Icu (415 V) = 70 kA
F = Front terminals
Electronic release
T5H 630 F F
320
400
In
F = Front terminals
Iu (40 C) = 630
059530
059532
A - Icu (415 V) = 50 kA
Electronic release
T5H 400 F F
T5H 400 F F
T5H 630
Fixed (F)
630
In
F = Front terminals
Iu (40 C) = 400
059529
059531
A - Icu (415 V) = 50 kA
F = Front terminals
Electronic release
T5S 630 F F
T5H 400
In
PR223DS
Electronic release
T5S 400 F F
T5S 400 F F
T5S 630
Fixed (F)
320
400
1SDA..R1
3 poles
4 poles
A - Icu (415 V) = 36 kA
F = Front terminals
Electronic release
T5N 630 F F
T5S 400
Fixed (F)
In
In
PR223DS
630
1SDA..R1
3 poles
4 poles
059545
059546
6/7
Ordering codes
Circuit-breaker T5 for power distribution
T5L 400
Fixed (F)
Iu (40 C) = 400
F = Front terminals
Electronic release
T5L 400 F F
T5L 400 F F
T5L 630
Fixed (F)
Iu (40 C) = 630
PR223DS
PR223DS
Iu (40 C) = 400
In
PR223DS
Iu (40 C) = 630
630
In
PR223DS
PR223DS
059548
059550
1SDA..R1
3 poles
4 poles
059551
059552
320
400
1SDA..R1
3 poles
4 poles
059553
059555
059554
059556
F = Front terminals
Electronic release
T5V 630 F F
059547
059549
F = Front terminals
Electronic release
T5V 400 F F
T5V 400 F F
T5V 630
Fixed (F)
320
400
1SDA..R1
3 poles
4 poles
F = Front terminals
Electronic release
T5L 630 F F
T5V 400
Fixed (F)
In
In
PR223DS
630
1SDA..R1
3 poles
4 poles
059557
059558
Releases for T5
In
Electronic release
PR223DS
PR223DS
PR223DS
320
400
630
1SDA..R1
3 poles
4 poles
059567
059569
059571
059568
059570
059572
6/8
ABB SACE
Ordering codes
Circuit-breaker T4 for power distribution
T4N 250
Fixed (F)
Iu (40 C) = 250
A - Icu (415 V) = 36 kA
F = Front terminals
Electronic release
T4N 250 F F
T4N 250 F F
T4N 250 F F
T4N 320
Fixed (F)
Iu (40 C) = 320
PR223DS
PR223DS
PR223DS
Iu (40 C) = 250
Iu (40 C) = 320
PR223DS
PR223DS
PR223DS
PR223DS
ABB SACE
1SDA..R1
3 poles
4 poles
059495
059496
1SDA..R1
3 poles
4 poles
059497
059499
059501
059498
059500
059502
320
1SDA..R1
3 poles
4 poles
059503
059504
A - Icu (415 V) = 70 kA
In
PR223DS
PR223DS
PR223DS
100
160
250
1SDA..R1
3 poles
4 poles
059505
059507
059509
059506
059508
059510
A - Icu (415 V) = 70 kA
F = Front terminals
Electronic release
T4H 320 F F
100
160
250
In
F = Front terminals
Iu (40 C) = 320
059490
059492
059494
A - Icu (415 V) = 50 kA
Electronic release
T4H 250 F F
T4H 250 F F
T4H 250 F F
T4H 320
Fixed (F)
320
In
F = Front terminals
Iu (40 C) = 250
059489
059491
059493
A - Icu (415 V) = 50 kA
F = Front terminals
Electronic release
T4S 320 F F
T4H 250
Fixed (F)
In
PR223DS
Electronic release
T4S 250 F F
T4S 250 F F
T4S 250 F F
T4S 320
Fixed (F)
100
160
250
1SDA..R1
3 poles
4 poles
A - Icu (415 V) = 36 kA
F = Front terminals
Electronic release
T4N 320 F F
T4S 250
Fixed (F)
In
In
PR223DS
320
1SDA..R1
3 poles
4 poles
059511
059512
6/9
Ordering codes
Circuit-breaker T4 for power distribution
T4L 250
Fixed (F)
Iu (40 C) = 250
F = Front terminals
Electronic release
T4L 250 F F
T4L 250 F F
T4L 250 F F
T4L 320
Fixed (F)
Iu (40 C) = 320
PR223DS
PR223DS
PR223DS
F = Front terminals
Iu (40 C) = 250
In
PR223DS
Iu (40 C) = 320
320
In
PR223DS
PR223DS
PR223DS
059514
059516
059518
1SDA..R1
3 poles
4 poles
059519
059520
100
160
250
1SDA..R1
3 poles
4 poles
059521
059523
059525
059522
059524
059526
F = Front terminals
Electronic release
T4V 320 F F
059513
059515
059517
F = Front terminals
Electronic release
T4V 250 F F
T4V 250 F F
T4V 250 F F
T4V 320
Fixed (F)
100
160
250
1SDA..R1
3 poles
4 poles
Electronic release
T4L 320 F F
T4V 250
Fixed (F)
In
In
PR223DS
320
1SDA..R1
3 poles
4 poles
059527
059528
Releases for T4
In
Electronic release
PR223DS
PR223DS
PR223DS
PR223DS
100
160
250
320
1SDA..R1
3 poles
4 poles
059559
059561
059563
059565
059560
059562
059564
059566
6/10
ABB SACE
Ordering codes
Circuit-breakers for advanced zone selectivity
T4L 250
Fixed (F)
Iu (40 C) = 250
F = Front terminals
In
Electronic release
T4L 250 F F
PR223EF
T4L 250 F F
PR223EF
T4L 250 F F
PR223EF
Note: Please ask ABB SACE for availability
T4L 320
Fixed (F)
Iu (40 C) = 320
Iu (40 C) = 400
In
Iu (40 C) = 630
059482
1SDA..R1
3 poles
4 poles
059483
059485
059484
059486
1SDA..R1
3 poles
4 poles
059487
059488
630
1SDA..R1
3 poles
4 poles
060261
060267
F = Front terminals
In
Iu (40 C) = 1000
800
1SDA..R1
3 poles
4 poles
060304
060310
F = Front terminals
Electronic release
T6L 1000 F F
PR223EF
Note: Please ask ABB SACE for availability
ABB SACE
630
In
Electronic release
T6L 800 F F
PR223EF
Note: Please ask ABB SACE for availability
T6L 1000
Fixed (F)
059481
F = Front terminals
Iu (40 C) = 800
320
400
In
Electronic release
T6L 630 F F
PR223EF
Note: Please ask ABB SACE for availability
T6L 800
Fixed (F)
1SDA..R1
3 poles
4 poles
F = Front terminals
Iu (40 C) = 630
320
In
Electronic release
T5L 630 F F
PR223EF
Note: Please ask ABB SACE for availability
T6L 630
Fixed (F)
059476
059478
059480
F = Front terminals
Electronic release
T5L 400 F F
PR223EF
T5L 400 F F
PR223EF
Note: Please ask ABB SACE for availability
T5L 630
Fixed (F)
059475
059477
059479
F = Front terminals
Electronic release
T4L 320 F F
PR223EF
Note: Please ask ABB SACE for availability
T5L 400
Fixed (F)
100
160
250
1SDA..R1
3 poles
4 poles
In
1000
1SDA..R1
3 poles
4 poles
060579
060585
6/11
Ordering codes
Circuit-breakers for motor protection
T6N 800
Fixed (F)
Iu (40 C) = 800
A - Icu (415 V) = 36 kA
F = Front terminals
Electronic release for motor protection
T6N 800 F F
PR222MP
T6S 800
Fixed (F)
Iu (40 C) = 800
F = Front terminals
Iu (40 C) = 800
Iu (40 C) = 800
630
060311
In
1SDA..R1
3 poles
630
060312
In
1SDA..R1
3 poles
630
060313
In
1SDA..R1
3 poles
630
060314
In
1SDA..R1
3 poles
630
060375
A - Icu (415 V) = 70 kA
F = Front terminals
Electronic release for motor protection
T6H 800 F F
PR222MP
T6L 800
Fixed (F)
1SDA..R1
3 poles
T6H 800
Fixed (F)
In
F = Front terminals
Electronic release for motor protection
T6L 800 F F
PR222MP
Releases for T6
F = Front terminals
Electronic release
PR222MP
6/12
ABB SACE
Ordering codes
Circuit-breakers for applications up to 1000 V
T6L 630
Fixed (F)
Iu (40 C) = 630
F = Front terminals
Electronic release
T6L 630 F F
PR221DS-LS/I
T6L 630 F F
PR221DS-I
T6L 630 F F
PR222DS/P-LSI
T6L 630 F F
PR222DS/P-LSIG
Note: Please ask ABB SACE for availability
T6L 800
Fixed (F)
Iu (40 C) = 800
Iu (40 C) =
Iu (40 C) =
630
630
630
630
060319
060320
060321
060322
In
1SDA..R1
3 poles
800
800
800
800
060323
060324
060325
060326
F = Front terminals
In
T6L 800
Fixed (F)
1SDA..R1
3 poles
F = Front terminals
Electronic release
T6L 800 F F
PR221DS-LS/I
T6L 800 F F
PR221DS-I
T6L 800 F F
PR222DS/P-LSI
T6L 800 F F
PR222DS/P-LSIG
Note: Please ask ABB SACE for availability
T6L 630
Fixed (F)
In
I3
31506300
1SDA..R1
4 poles
060315
F = Front terminals
In
I3
40008000
1SDA..R1
4 poles
060317
ABB SACE
6/13
Ordering codes
Switch-disconnectors
T6D 630
Fixed (F)
Iu (40C) = 630
A - Icw = 15 kA
F = Front terminals
Electronic release
T6D 630 F F
T6D 800
Fixed (F)
Iu (40C) = 800
060343
060344
A - Icw = 15 kA
F = Front terminals
Electronic release
T6D 800 F F
T6D 1000
Fixed (F)
1SDA..R1
3 poles
4 poles
Iu (40C) = 1000
1SDA..R1
3 poles
4 poles
060345
060346
A - Icw = 15 kA
F = Front terminals
Electronic release
T6D 1000 F F
Note: Please ask ABB SACE for availability
1SDA..R1
3 poles
4 poles
060594
060595
6/14
ABB SACE
Ordering codes
Fixed parts, conversion kits and interruption parts
Withdrawable (W)
Fixed part
Withdrawable (W)
Fixed part
Withdrawable (W)
Fixed part
Conversion
of the version
Terminals
for fixed parts
Interruption parts
1SDA..R1
3 poles
4 poles
T6 W FP EF
060384
1SDA..R1
3 poles
4 poles
T6 W FP VR
060386
1SDA..R1
3 poles
4 poles
T6 W FP HR
060385
Type
1SDA..R1
3 poles
4 poles
060390
Type
1SDA..R1
3 poles
4 poles
EF
HR
VR
013984
013986
013988
060387
060389
060388
060391
013985
013987
013989
T6 630
F = Front terminals
1SDA..R1
3 poles
4 poles
060327
060328
060329
060330
060331
060332
060333
060334
T6 800
F = Front terminals
1SDA..R1
3 poles
4 poles
060335
060336
060337
060338
060339
060340
060341
060342
T6 1000
ABB SACE
F = Front terminals
1SDA..R1
3 poles
4 poles
060586
060587
060588
060589
060590
060591
060592
060593
6/15
Ordering codes
Accessories
Service releases
1SDC210166F1002
1SDC210165F1002
Type
uncabled version
SOR 12 V DC
SOR 24...30 V AC / DC
SOR 48...60 V AC / DC
SOR 110...127 V AC - 110...125 V DC
SOR 220...240 V AC - 220...250 V DC
SOR 380...440 V AC
SOR 480...525 V AC
cabled version
SOR-C 12 V DC
SOR-C 24...30 V AC / DC
SOR-C 48...60 V AC / DC
SOR-C 110...127 V AC - 110...125 V DC
SOR-C 220...240 V AC - 220...250 V DC
SOR-C 380...440 V AC
SOR-C 480...525 V AC
1SDA.....R1
T4-T5-T6
054862
054863
054864
054865
054866
054867
054868
054869
054870
054871
054872
054873
054874
054875
1SDC210166F1002
1SDC210165F1002
Type
uncabled version
UVR 24...30 V AC / DC
UVR 48 V AC / DC
UVR 60 V AC/DC
UVR 110...127 V AC - 110...125 V DC
UVR 220...240 V AC - 220250 V DC
UVR 380...440 V AC
UVR 480...525 V AC
cabled version
UVR-C 24...30 V AC / DC
UVR-C 48 V AC / DC
UVR-C 60 V AC/DC
UVR-C 110...127 V AC - 110...125 V DC
UVR-C 220...240 V AC - 220250 V DC
UVR-C 380...440 V AC
UVR-C 480...525 V AC
1SDA.....R1
T4-T5-T6
054880
054881
054882
054883
054884
054885
054886
054887
054888
054889
054890
054891
054892
054893
1SDA.....R1
T4-T5-T6
054876
054877
054878
054879
6/16
1SDA.....R1
T1...T6
051357
051358
051360
051361
ABB SACE
Electrical signals
1SDA.....R1
T1...T6
060392
051365
051366
051367
1SDC210168F1002
1SDC210167F1002
T6
051362
051363
051364
1SDA.....R1
T4-T5-T6
T6
uncabled version
AUX 1Q 1SY 250 V AC/DC
051368
AUX 3Q 1SY 250 V AC/DC
051369
AUX 3Q 1SY 24 V AC/DC
054914
cabled version
AUX-C 1Q 1SY 250 V AC/DC
054910
AUX-C 3Q 1SY 250 V AC/DC
054911
AUX-C 1Q 1SY 400 V AC
054912
AUX-C 2Q 400 V AC
054913
AUX-C 3Q 1SY 24 V AC/DC
054915
cabled contact in electronic version
AUX-E-C 1Q 1SY
054916
cabled contact for signalling manual/remote operation
054917
AUX-MO-C(1)
cabled contact for signalling trip coil release trip
AUX-SA 1 S51
060393
(1)
For T4-T5-T6 in plug-in/withdrawable versions it is necessary to order a socket-plug connector 3 poles 1SDA051364R1.
1SDA.....R1
T4-T5-T6
054920
054918
054921
054919
Type
ABB SACE
1SDA.....R1
T6
060394
6/17
Ordering codes
Accessories
Adapters - ADP
1SDC210171F1002
Type
ADP - Adapters 5pin
ADP - Adapters 6pin
ADP - Adapters 12pin
ADP - Adapters 10pin
1SDA.....R1
T4-T5-T6
055173
054922
054923
054924
Testing extension
1SDC210172F1002
Type
5-pin checking extension for blank tests on T4-T5-T6 P/W service releases
6-pin checking extension for blank tests on auxiliary contacts, (1+1)
service and residual current releases T4-T5-T6 P/W
12-pin checking extension for blank tests on auxiliary contacts (3+1) T4-T5-T6 P/W
10-pin checking extension for blank tests on motor operator
and early contacts T4-T5-T6 P/W
1SDA.....R1
T4-T5-T6
055351
055063
055064
055065
1SDC210173F1002
Type
MOE T6 24 V DC
MOE T6 48...60 V DC
MOE T6 110...125 V AC/DC
MOE T6 220...250 V AC/DC
MOE T6 380 V AC
1SDA.....R1
T6
060395
060396
060397
060398
060399
1SDA.....R1
T6
060400
060401
060402
060403
060404
Note: always supplied complete with the AUX-E-C electronic auxiliary contact.
6/18
ABB SACE
Direct - RHD
operating mechanism
Type
1SDC210175F1002
1SDC210174F1002
Rotary handle
1SDA.....R1
T6
060405
060406
060407
060408
Transmitted - RHE
Type
1SDA.....R1
T6
060409
060410
060411
060412
060413
060414
054932
060415
060416
1SDC210177F1002
1SDC210176F1002
1SDA.....R1
T4-T5-T6
054938
1SDC210178F1002
Type
1SDA.....R1
T4-T5
T6
054939
054940
054941
054942
054943
1SDC210179F1002
Operating
ABB SACE
060658
060659
060660
060661
060662
6/19
Ordering codes
Accessories
1SDC210180F1002
1SDA.....R1
T4-T5
T6
054904
054905
054906
054907
054908
054909
060611
060612
060613
060614
060615
060616
1SDC210181F1002
Type
FLD - for fixed and plug-in
FLD - for withdrawable
1SDA.....R1
T6
060417
060418
1SDA.....R1
T6
060685
060686
1SDC210182F1002
Type
KLF-D FP - Different key for each circuit-breaker
KLF-S FP - Same key for different groups of circuit-breakers
PLL FP - Lock padlocks
KLF-D Ronis FP - Lock Ronis type
Residual
SACE RCQ
current release
Type
6/20
1SDA.....R1
T4-T5-T6
055230
055231
055232
055233
1SDA.....R1
T1...T6
037388
037389
050542
037390
037391
037392
037393
037394
037395
050543
037396
037397
037398
ABB SACE
Type
1SDA.....R1
3 poles
4 poles
HTC S6-T6
014040
014041
1SDC210184F1002
1SDC210183F1002
1SDC210186F1002
1SDC210185F1002
1SDA.....R1
3 poles
4 poles
LTC S6-T6
014038
014039
Type
Sealable screws
1SDA.....R1
S6...T6
013699
Type
1SDC210189F1002
1SDC210188F1002
Separating partitions - PB
PB - pieces 4 - 3p
PB - pieces 6 - 4p
1SDA.....R1
S6-S7-T6
050696
050697
ABB SACE
6/21
Ordering codes
Accessories
Connecting terminals
Type
1SDC210192F1002
1SDC210191F1002
1SDC210190F1002
EF S6 630 - T6 630
EF S6 800 - T6 800
FC CuAl S6 630 - T6 630 2x240mm2
FC CuAl S6 800 - T6 800 3x185mm2 - external terminal
FC CuAl T6 1000 4x150 mm2 - external terminal
F T6 630 - T6 800 - Plugs with screws (1)
ES S6 - T6 (1/2 upper kit) 630 - T6 800
ES S6 - T6 630 - T6 800
R T6
RC S6 630 - T6 630 2x150 mm2
RC S6 800 - T6 800 3x240 mm2
(1)
4 pieces
6 pieces
8 pieces
023379
023383
023380
023384
060687
060421
050692
050704 (2)
060425
023381
023385
023389
023393
023390
023394
060688
060422
013920
013954
013922
013956
060689
060423
013921
013955
013923
013957
060690
060424
050693
060426
023391
023395
050688
060427
013924
013958
050689
060428
013925
013959
1SDC210194F1002
1SDC210193F1002
(2)
1SDA.....R1
3 pieces
1SDA.....R1
T4-T5
T6
055051
1SDC210195F1002
060429
6/22
ABB SACE
1SDA.....R1
052927
1SDA.....R1
T4-T5-T6
LSI
LSIG
055066
055067
Note: To be specified only in addition to the code of the automatic circuit-breaker, with analogous overcurrent release (PR222DS/P). To order
the release separately, see page 6/6.
1SDC210196F1002
Type
Connector X4 release tripped signal and neutral protection for plug-in
or withdrawable with PR222DS or PR223DS
Connector X3 release tripped signal for plug-in or withdrawable with PR222DS or PR223DS
Connettor X4 release tripped signal for fixed with PR222DS or PR223DS
Connettor X3 release tripped signal for fixed with PR222DS or PR223DS
CT for withdrawable external neutral - T6 630
CT for withdrawable external neutral - T6 800
CT for withdrawable external neutral - T6 1000
TT1 - Test unit
PR010/T - Test and configuration unit with electronic releases
PR222DS/P, PR222DS/PD, PR222MP or PR223DS
PR021/K - Signalling unit with electronic releases PR222DS/PD, PR222MP or PR223DS
PR212/CI - Contactor control for PR222MP
EP010 - Interfacing module for PR222/PD
Measuring module VM210 for PR223DS-EF
Interlock module IM210 for PR223EF - PR12x
Note: Please ask ABB SACE for availability
1SDA.....R1
T4-T5-T6
055062
055061
055060
055059
060430
060431
060610
037121
048964
059146
050708
059469
059602
059603
ABB SACE
6/23
L.V. Breakers
Via Baioni, 35
24123 Bergamo, Italy
Tel.: +39 035.395.111 - Telefax: +39 035.395.306-433
http://www.abb.com
1SDC210012D0201 - 04/2005
Printed in Italy
Tipografia