Sunteți pe pagina 1din 2

UNILAB ELECTRIC SUITE

Over 300 customers in 50 countries

UNILAB ELECTRIC SUITE is the last generation of software for design and rating of electric heat exchangers.
The software calculates electric coils with or without
fins, electric shell with Single Phase fluids, electric vaporizers with Bi Phase fluids (with or without overheating) and indirect electrical heaters. These exchangers
are often used in Refining, Power, Pulp and Paper, Gas
Engine and Gas Compression industries.
When you design an electric shell heater, there is a
sketch of the plate drawing to help the study of the resistances distribution.
UNILAB ELECTRIC SUITE (like all UNILAB software) has
a wide variety of fluids. It contains the thermodynamic
and thermophysical properties of more than 300 liquids
& gases, 12 mixtures of liquids and all the fluids inside
the REFPROP of NIST (National Institute of Standards
and Technology).
UNILAB ELECTRIC SUITE is the best solution for companies with a diverse production. Using a single program, you will simplify work procedures, unifying different projects. The software is composed by modules, as
described below.

BASIC MODULE

FINNED COIL

SMOOTH COIL

The basic module enables the


usage of the program and includes the fluid library above,
and other parameters tables. It
is possible to mix them, according to your request.

Module for design and verification of heat exchangers with


finned pack electrical resistances. They are transversal to the
fluid flow in treatment and sustained by a frame.

Module for design and verification of heat exchangers composed by smooth electrical resistances, transverse to the fluids flow.

SHELL

VAPORIZER

INDIRECT HEATER

Module for design and verification of exchangers used to heat


gases and liquids without
change phase and composed
by a Shell heat exchangers.

Module for verification of heat


exchangers that are designed to
transform a liquid into gas
(vaporization), when there is a
phase change.

Module for design and rating of


heaters immersed in a liquid
which is inside a tank. The electric resistances warm the liquid
(glycol, oil, etc..) which warms
the gas in the serpentines.

FUNCTIONALITIES
Calculation
modalities
Archive
management
Geometries
Materials

Fluids

Printouts
Drawings

Plate
drawing

Graphs
Correction
factors
Logo
Unit of
measurement
Projects
archive
Languages
Technical
support
Activation
modality
System
requirements

In verify
In design
Analysis of the phase transition: liquid-gas
Archive of materials, resistances, fins, geometries
Set, edit and erase the customers data, materials and fluids
Management of the geometrys data (fins and resistances)
and it is possible to add new ones
Management of the materials data and it is possible to add
new ones, specifying and inserting the following information:
Thermal Conductivity (W/m*K) and Density (kg/m3)
Use the fluids archive or add new ones
Fluids test with charts and/or tables
Insertion and usage of the Fluid Custom directly on the calculations mask (insert the thermophysical properties at the
average temperature)
Gases (pure and mixtures)
Liquids (pure and mixtures)
Refrigerants (ammonia, ethane, methane, propane, water)
Technical data
Further technical data
Exporting printouts to PDF, Word and Excel
Change the language directly on the printout
Print and export the drawings to PDF, Excel, Word formats
Add new drawings and manually specify the quotes
Design the plan of the plate automatically with the maximum
number of tubes possible (on the plate)
Manually delete tubes and modify information directly on the
drawing (like the tube disposition and the plate configuration) so the drawing will update automatically
Save the data that was modified directly on the drawing and
transfer them back to the calculation mask
Drawings can be exported into AutoCad (DXF)
Sheath temperature vs. rows number
Sheath temperature vs. fluid rate
Pressure drop vs. fluid rate
Exporting graphs to various formats (PDF, Word, PNG, etc)
These correction factors align the softwares results (with
approximation margin) with the experimental data
Logo and company data linked to the main brand of the
company
Choose, customize or modify the units of measurement: SI,
Imperial and Custom
Calculations can be saved and restored in files of small dimensions
Italian and English, other languages on request, with additional cost
Unicode support for non Latin alphabets
Available only to customers under subscription of the
maintenance contract
Automatic renewal of maintenance contract and it covers a
maximum of no. 3 technical licenses
Digital download - an internet connection is required for both
installation and activation. Further accesses to the internet
connection may be required while using the software
Operating System Microsoft Windows Vista, 7 and 8
32 or 64 bits

Book a demonstration online at:

bit.ly/unilabdemo

Watch videos at:

bit.ly/unilabyoutube

Finned
coil

Smooth
coil

Shell

Vaporizer

Indirect
heater

Follow us on:

bit.ly/unilablinkdin

Unilab Srl - Via Nino Bixio, 6 35131 Padova, Italy


Tel: +39 (0)49 8763311 Fax: +39 (0)49 8750196 - VAT no.: IT01334900287
Website: unilab.eu - E-mail: sales@unilab.eu