Sunteți pe pagina 1din 3

Callidus Low NOx Staged Gas Burner (CSGL)

DESIGNED FOR LOW NOx EMISSIONS

Advanced Burner Technology

Callidus Low NOx Staged Gas (CSGL) Burners



Extremely Stable

becoming the preferred staged

Able to fit in virtually any


application

gas low NOx process burner.

Natural draft or forced draft

10 to 1 turndowns

The Callidus (CSGL) is rapidly

An innovative design has been

The CSGL is stable and can achieve

Flat flame or round flame

Shorter Flame Lengths

employed which increases the

2 MM Btu/hr to 26 MM Btu/hr with

burners stability and allows for

higher levels possible

optimal performance on typical

Round flame tile has the smallest

Better NOx Reduction

refinery fuel gases and 100% natural

diameter of any comparable duty,

gas. The new design also increases

40-50 ppmv are typical without any

ultra-low NOx burner available,

the tile exit velocity which enhances

additional technologies (steam,

allowing for retrofits without floor

fuel/flue gas/air mixing, providing a

external flue gas, etc.)

modifications

shorter, stiffer flame as compared

Fires vertical (up or down) or

to other next generation Ultra-low


NOx burner designs.

Typical flame length of (1.56 m/MW)

The CSGL is a staged, gas, internal


flue gas recirculation burner

horizontally
Operates with a wide range of fuels

Reduced Maintenance

Using our extensive engineering

Perfect for retrofit of older heaters

No metallic flame holders to burn up

experience and ground breaking

originally designed for conventional

Primary tips are well away from the

innovation, Callidus designed the

raw gas and premix burners

combustion and cooled by air

CSGL to meet our customers

stream

challenges.

Staged tips are shielded by


refractory

With specific requests and


developmental mandates from
the industrys leading companies,
the CSGL was created with these

CSGL Capacities
Heat Release vs. Airside Pressure Drop

distinct advantages:

CSGL Capacities (Heat Release vs. Airside Pressure Drop)


30.00

No special operating needs


The CSGL does not require

SIZE 16

start-up lances or special

SIZE 14

Operations are no different than


a conventional burner

Heat Release (MMBtu/hr)

procedures
SIZE 12

20.00

SIZE 10
SIZE 9
SIZE 8
SIZE 7
SIZE 6

10.00

SIZE 5
SIZE 4
SIZE 3
SIZE 2

0.00
0

0.1

0.2

0.3

0.4

0.5

Airside Pressure Drop (inches w.c.)

0.6

0.7

0.8

0.9

Computational Fluid
Dynamic Modeling

ISO 9001:2008 Certification

Our in-house Computational Fluid


Dynamic Modeling (CFD) capabilities
combinedwith Fluentsoftwarecreates
3-D models of fired equipment. These
CFD models are combined with real world
experience and years of Callidus proven
Callidus headquarters - Tulsa, Oklahoma. USA

Global Coverage

R&D, to predict field performance of entire


systemsto avoid potential performance
problems prior to fabrication.

Tulsa, Oklahoma, USA, regional direct


sales offices in China, Belgium, India
and Brazil and with independent sales
representation around the world. Meeting
our customers expectations and setting

China Certification

At Callidus, quality assurance is


everyones job. Every step of the project

Callidus reaches the global market


through our headquarters located in

USA Certification

Advanced Manufacturing and


Fabrication Capabilities

is consistently reviewed to ensure that


we live up to the expectations of the
customer.

Upgrading our manufacturing and


fabrication facilities is an ongoing process
at Callidus. Our fabrication facilities

R&D Test Facility

employ the latest manufacturing practices

The Callidus,290 acre,R&D facility is in

and equipment. As a global leader in the

continual use for combustion technology

combustion technology market, much

research and development as well as

of our fabrication occurs in strategic

customer witnessed demonstrations.

in mind.

locations around the world.This approach

Our array of test systems allows us to

makes good economic sense, and

closely match actual field operating

Callidus Corporate Headquarters, USA

provides our customers the best value for

conditions, providing results which will

7130 South Lewis, Suite 335

their combustion system.

more accurately predict actual measured

the standards for the combustion industry


have always been our company goals.
Each burner system we design and
manufacture is built with those goals

performance.

Tulsa, OK 74136
Phone: +1 918 496 7599
Fax: +1 918 488 9450

Quality In Everything We Do

www.callidus.com

Our manufacturing facility demonstrates

Brussels, Belgium:

industry. In some cases, many of our

Phone: +32 2255 0909

the highest quality standards in the


internal quality assurance programs

Fax: +32 2251 8241

require higher performance standards

Sao Paulo, Brazil:

fabrication and manufacturing are certified

Phone: +55 11 3475 1885

than some industry certifications. Callidus


ISO 9001:2008 in USA and China.

Fax: +55 11 3475 1901


Shanghai, China:
Phone: +86 21 2894 3088
Fax: +86 21 5895 7546
Mumbai, India
Phone: +91 22 2582 2639
Fax: +91 22 2582 3345

April 2010
2010 Honeywell International Inc.

Callidus 82,000 sq. ft. manufacturing and


fabrication facility in USA

S-ar putea să vă placă și