Sunteți pe pagina 1din 11

POWER ELECTRONICS-LAB (EE-321-F)

1.

STATIC CHARACTERISTICS OF POWER DIODE & SHOTTKY


DIODE AND TO STUDY REVERSE RECOVERY OF POWER
DIODE & SHOTTKY DIODE.
*
*
*
*
*
*
*
*

2.

CHARACTERISTICS OF IGBT & GTO


*
*
*
*
*
*

3.

SPECIFICATION
Study of IGBT characteristics
Ammeter
Voltmeter
Variable DC power supply: 12 V
Various test points
Detailed instruction manual
TO STUDY R, RC AND UJT FIRING CIRCUIT WITH PULSE
TRANSFORMER

*
*
*
*
*
4.

SPECIFICATION
To study the V-I Characteristics of Schotkey Diode
Digital Voltmeter and Ammeter
Ammeter
Voltmeter
Variable DC power supply: 12 V
Various test points
Reverse and Forward Characteristics can be performed
Detailed instruction manual

This trainer helps to study of R & RC Trigger Circuits. The


inbuilt power supply vanishes the hurdels of connecting
seperate power supply. The circuit diagram of R & RC
Trigger Circuits are printed on the board, so students can
understand the working of R & RC Triggered Circuit.
Half wave phase control using R triggered circuit & SCR.
Full wave phase control using RC triggered circuit &
TRIAC.
R triggering circuit.
Lamp load
Set of Patch chords & User's Manual.
TO STUDY OF FIRING CIRCUIT BASED ON ICS NE555,
7408 & 3140

SPECIFICATION
* Firing circuits on single board based on NE555, 7408 &
3140
* Gradual firing angle control.
* Test points for observe output of different circuits.
* Sockets to make different connections.
* Different experiments can be performed on single board.
* Detailed instruction manual
5.

TO STUDY OF PULSE TRANSFORMER & OPTOCOUPLER


TECHNIQUE
SPECIFICATION
* Firing circuits on single board using pulse transformer &

*
*
*
*
*
6.

opto coupler
Gradual firing angle control.
Test points for observe output of different circuits.
Sockets to make different connections.
Different experiments can be performed on single board.
Detailed instruction manual
TO STUDY OF SCR COMMUNICATION TECHNIQUE
CLASS A-E

SPECIFICATION
* In built AC and DC Power Supply
* On Board Firing circuit Board having more than 6
Communication circuit,
* On boards containing Pulse Transformer,
* Test point given for Observe Waveforms.
* Isolation between SCR and Firing angle Circuit.
* Detailed instruction manual

7.
SPEED CONTROL OF SMALL MOTOR USING SINGLE PHASE
HALF WAVE & FULL WAVE FULLY CONTROLLED CONVERTER
SPECIFICATION
* Power supply requirement : 230V AC, 1 Phase.
* Following parts provided on Single PCB with connecting
terminals.
* SCR 4 Nos.
* Digital Firing Control: 0-180 degree
* Load Resistor, Load Inductor
* On Board Digital Voltmeter
* On Board Digital Current Meter
* Standard Accessories:
* Training Manual.
* Connecting Patch cords.
* DC Motor HP
* Detailed instruction manual

8.

SPEED CONTROL OF SMALL MOTOR USING SINGLE PHASE


DUAL CONVERTER

9.

STUDY OF MC MURRAY - BED FORD HALF & FULL BRIDGE


INVERTER
*
*
*
*

10.

TO STUDY PARALLEL INVERTER TO DRIVE SMALL AC


INDUCTION MOTOR
*
*
*
*
*

11.

SPECIFICATION
On board Firing circuit
Inbuilt Pulse Transformer for Isolation.
Inbuilt Power supply.
Test Point given for Observe Waveforms

SPECIFICATION
On board Firing circuit
Inbuilt Pulse Transformer for Isolation.
Inbuilt Power supply.
Test Point given for Observe Waveforms.
Motor: HP Induction Motor

SPEED CONTROL OF A SMALL DC MOTOR USING MOSFET

NO QUOTE

BASED CHOPPER WITH OUTPUT VOLTAGE CONTROL


TECHNIQUE
SPECIFICATION
* On board Firing circuit ,Test point provided to check Output
at different block in built
* Power supply. Sockets are provided to make connections
* Chopper Based Motor Control Circuit
* On Board Digital Volt Meter
* On Board Digital Current Meter
* Lamp Load
* Motor: HP DC Motor

12.

SPEED CONTROL OF SMALL AC INDUCTION MOTOR USING


SINGLE PHASE NON CIRCULATING TYPE BRIDGE BY
FREQUENCY CONVERSION
FEATURE
* All the components are fixed on bakelite sheet in a table top based
cabinet design
* Diagrammatic representation of concept
* Onboard Voltmeter
* Induction Motor (1HP)
* Onboard Ammeter
* Indicating Light
* User's Manual with patch cords.
* Educational standard 4mm wire connector and insulated terminals

ELECTRICAL MACHINES-II LAB (EE-327-F)


1.

STUDY OF THE NO LOAD AND BLOCK ROTOR TEST IN A


THREE PHASE SLIP RING INDUCTION MOTOR & DRAW ITS
CIRCLE DIAGRAM
FEATURE
* All the components are fixed on bakelite sheet in a table top based
cabinet design
* Diagrammatic representation of concept
* Onboard Voltmeter 0-300V
* Onboard Ammeter 0-5A
* Onboard Wattmeter 5/10A, 300/600V-02 Nos.
* Motor : 3 Phase AC Slip Ring Motor 3HP
* Speed : 1440 RPM
* Supply : 3 Phase 415V 3.6/4.8 A
* Mechanical Loading Arrangement
* Facility to plot the following curves
* Efficiency Vs Output Power
* Torque Vs Output Power
* Line Current Vs Output Power
* Power Factor Vs Output Power
* Slip Vs Output Power
* Torque Vs Speed
* Indicating Light
* User's Manual with patch cords.
* Educational standard 4mm wire connector and insulated terminals

2.

TO STUDY THE STARTING OF SLIP RING INDUCTION


MOTOR BY ROTOR RESISTANCE STARTER
FEATURE
* All the components are fixed on bakelite sheet in a table top based

*
*
*
*
*
*
*
*
*
*

3.

cabinet design
Diagrammatic representation of concept
Onboard digital Voltmeter
Onboard digital Ammeter
MCB for input protection
Starter: Rotor resistance type
Auto transformer starter
Motor: Three Phase Induction motor. (1HP)
Speed: 1420RPM
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated terminals

TO STUDY AND MEASURE DIRECT AND QUADRATURE AXIS


REACTANCE OF A 3 PHASE ALTERNATOR BY SLIP TEST
SPECIFICATION
* All the components are fixed on bakelite sheet in a table top based
cabinet
* Diagrammatic representation of concept
* Onboard digital Voltmeter
* Onboard digital Ammeter
* DC Shunt Motor Specifications (acts as Prime Mover)
* Rating : 2HP
* RPM : 1500 (no load)
* Insulation : Class B
* Synchronous Motor Specifications (acts as Generator)
* Rating : 3HP
* RPM : 1500 (no load)
* Insulation : Class B
* Rheostat 2.8A, 300 ohms
* Three Phase Variac, 10A
* Stand alone operation
* Indicating Light
* User's Manual with patch cords.
* Educational standard 4mm wire connector and insulated terminals

EXPERIMENT THAT CAN BE PERFORMED


* Study and Measurement of Direct Axis and Quadrature Axis
Reactance by Slip Test
OPTIONAL ACCESSORIES REQUIRED
AC TO DC RECTIFIER POWER SUPPLY (220V/40A)
4.

TO STUDY AND MEASURE POSITIVE, NEGATIVE AND ZERO


SEQUENCE IMPEDANCE OF A ALTERNATOR
SPECIFICATION
* All the components are fixed on bakelite sheet in a table top based
cabinet
* Diagrammatic representation of concept
* Onboard digital Voltmeter
* Onboard digital Ammeter
* DC Shunt Motor Specifications (acts as Prime Mover)
* Rating : 2HP
* RPM : 1500 (no load)
* Insulation : Class B
* Synchronous Motor Specifications (acts as Generator)
* Rating : 3HP
* RPM : 1500 (no load)
* Insulation : Class B
* Rheostat
* Three Phase Variac, 8A
* Stand alone operation
* Indicating Light
* User's Manual with patch cords.

* Educational standard 4mm wire connector and insulated terminals

EXPERIMENT THAT CAN BE PERFORMED


* to study and measure positive, negative and zero sequence
impedance of a alternator

OPTIONAL ACCESSORIES REQUIRED


AC TO DC RECTIFIER POWER SUPPLY (220V/40A)
5.

TO STUDY AND MEASURE SYNCHRONOUS IMPEDANCE AND


SHORT CIRCUIT RATIO OF SYNCHRONOUS GENERATOR
SPECIFICATION
* All the components are fixed on bakelite sheet in a table top based
cabinet
* Diagrammatic representation of concept
* Onboard digital Voltmeter
* Onboard digital Ammeter
* DC Shunt Motor Specifications (acts as Prime Mover)
* Rating : 2HP
* RPM : 1500 (no load)
* Insulation : Class B
* Synchronous Motor Specifications (acts as Generator)
* Rating : 3HP
* RPM : 1500 (no load)
* Insulation : Class B
* Rheostat 2.8A, 300 ohms
* Three Phase Variac, 10A
* Stand alone operation
* Indicating Light
* User's Manual with patch cords.
* Educational standard 4mm wire connector and insulated terminals

EXPERIMENT THAT CAN BE PERFORMED


* To study and measure synchronous impedance and short circuit
ratio of synchronous generator

OPTIONAL ACCESSORIES REQUIRED


AC TO DC RECTIFIER POWER SUPPLY (220V/40A)
6.
7.

STUDY OF POWER (LOAD) SHARING BETWEEN TWO THREE01


PHASE ALTERNATORS IN PARALLEL OPERATION CONDITION
SYNCHRONIZATION OF TWO THREE PHASE ALTERNATORS, BY
A) SYNCHROSCOPE METHOD
B) THREE DARK LAMP METHOD
C) TWO BRIGHT ONE DARK LAMP METHOD

FOR EXPERIMENT NO. 6 & 7


SPECIFICATION:
* All the components are fixed on bakelite sheet in a table top based
cabinet design
* Diagrammatic representation of concept
* Onboard Voltmeter
* Onboard Ammeter
* Onboard Wattmeter
* Phase Sequence indicator
* DC Machine (Prime Mover)
* DC Shunt
* Rating : 2 HP
* RPM : 1500
* Three Phase Machine (Generator)

*
*
*
*
*

Rating : 3 HP
RPM : 1500
Indicating Light
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated terminals

EXPERIMENT THAT CAN BE PERFORMED


* Study of Power (Load) sharing between Two Three Phase
alternators in parallel operation condition transfer of power from one
alternator to other alternator in parallel operation
* Synchronization
of
two
Three
Phase
Alternators,
by
Synchronoscope Method
- Three dark lamp Method
- Two bright one dark lamp method

OPTIONAL ACCESSORIES REQUIRED


AC TO DC RECTIFIER POWER SUPPLY (220V/40A)
8.

TO PLOT V- CURVE OF SYNCHRONOUS MOTOR


SPECIFICATION:
* All the components are fixed on bakelite sheet in a table top based
cabinet design
* Diagrammatic representation of concept
* Onboard Voltmeter
* Onboard Ammeter
* Onboard Wattmeter
* DC Shunt Generator
* Rating : 2 HP
* RPM : 1500
* Three phase synchronous motor
* Rating : 3 HP
* RPM : 1500
* Indicating Light
* Three phase Variac (10A) Closed Type
* Rheostat 2.8 A, 220 ohm
* Rheostat 5 A,110 ohm
* Digital Tachometer
* User's Manual with patch cords.
* Educational standard 4mm wire connector and insulated terminals

EXPERIMENT THAT CAN BE PERFORMED


* To plot V- Curve of synchronous motor.

OPTIONAL ACCESSORIES REQUIRED


AC TO DC RECTIFIER POWER SUPPLY (220V/40A)
9.

TO STUDY AND VERIFY LOAD CHARACTERISTICS OF


LONG SHUNT & SHORT SHUNT COMMUTATIVELY
COMPOUND GENERATOR USING 3 PHASE INDUCTION
MOTOR AS PRIME MOVER
SPECIFICATION
* All the components are fixed on bakelite sheet in a table top
based cabinet
* Diagrammatic representation of concept
* Machine used as prime mover

*
*
*
*
*
*
*
*
*
*
*
*

Three phase induction motor (3HP)


Compound generator 2KVA
Onboard DC Voltmeter 2 Nos.
Onboard DC Ammeter 2 Nos.
Onboard AC Voltmeter 1 Nos.
Onboard AC Ammeter 1 Nos.
Indicating Light
Three phase Variac (10 A) closed type
Rheostat 5 A,110 ohm
Resistive Load 3.5KW
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated
terminals

EXPERIMENT THAT CAN BE PERFORMED


* Study and verify the Load Characteristics of long Shunt
Comulatively Compound Generator
* Study and verify the Load Characteristics of short Shunt
Comulatively Compound Generator
OPTIONAL ACCESSORIES REQUIRED
AC TO DC RECTIFIER POWER SUPPLY (220V/40A)
10.

TO PERFORM O.C. TEST ON SYNCHRONOUS GENERATOR


AND DETERMINE THE FULL LOAD REGULATION OF A THREE
PHASE SYNCHRONOUS GENERATOR BY SYNCHRONOUS
IMPEDANCE METHOD
SPECIFICATION
* All the components are fixed on bakelite sheet in a table top
based cabinet
* Diagrammatic representation of concept
* Onboard Voltmeter - 2 No.
* Onboard Ammeter - 2 No.
* Onboard Wattmeter
* DC Shunt Motor
* Salient Pole Generator
* Experiment panel that contains :* MCB
* Tachometer
* Indicating Light
* User's Manual with patch cords.
* Educational standard 4mm wire connector and insulated
terminals
EXPERIMENT THAT CAN BE PERFORMED
* To perform o.c. test on synchronous generator and determine
the full load regulation of a three phase synchronous
generator by synchronous impedance method

OPTIONAL ACCESSORIES FOR ABOVE ITEMS


(WHEREVER REQUIRED)
AC TO DC RECTIFIER POWER SUPPLY (220V/40A)
SPECIFICATION
* DC Power Supply 200V/40A

*
*
*
*

On Board Voltmeter
On Board Ammeter
MCB 20A
Variable Supply 0 220V

POWER SYSTEMS LAB (EE-328-F)


1.

TO DRAW THE OPERATING CHARACTERISTCS OF IDMT


RELAY
*
*
*
*
*
*
*
*
*
*
*
*
*
*

2.

Diagrammatic representation on concept on the panel


On board built in digitals meters
Indicating lights
Onboard Digital Voltmeter
Onboard Digital Ammeter
Loading current transformer
Auto transformer 0-270W
IDMT Relay type CDG
Timer with Start and Stop facility
Push Button for Timer start & stop
Rotary Switch
DP Switch
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated terminals

TO STUDY THE PERFORMANCE OF EARTH FAULT RELAY


*
*
*
*
*
*
*
*
*
*

Diagrammatic representation on concept on the panel


On board built in digitals meters
Indicating lights
Onboard Digital Ammeter AC 0-5A - 03 Nos.
Onboard Digital Ammeter AC 0-1A
Rheostat- 100ohm-5A -03 Nos.
Auxiliary DC supply 110V
Onboard digital timer
Three phase auto transformer
Static IDMT Earth fault Relay

*
*
*
*
*

3.

Timer with Start and Stop facility


Push Button for Timer start & stop
DP Switch
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated terminals

TO STUDY PERFORMANCE OF A OVER VOLTAGE RELAY


*
*
*
*
*
*
*
*
*
*
*

4.

Diagrammatic representation on concept on the panel


On board built in digitals meters
Indicating lights
Rheostat- 400ohm/1.7A
Auxiliary DC supply 110V
Onboard digital timer
Single phase auto transformer 230V/4A
Static Over voltage Relay
DP Switch
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated terminals

TO STUDY PERFORMANCE OF UNDER VOLTAGE RELAY


*
*
*
*
*
*
*
*
*
*
*
*

5.

Diagrammatic representation on concept on the panel


On board built in digitals meters
Indicating lights
Rheostat- 400ohm/1.7A
Auxiliary DC supply 110V
Onboard digital Voltmeter
Variable voltage source
Onboard digital timer
Single phase auto transformer 230V/4A
DP Switch
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated terminals

TESTING OF BREAKDOWN STRENGTH OF A


TRANSFORMER OIL
TO STUDY FLASH POINT TEST OF TRANSFORMER OIL

6.

FOR EXPERIMENT NO. 5 & 6


*
*
*
*
*
*
*
7.

On board built in digitals meters


Onboard Digital Voltmeter
Onboard Lamp
Indicating lights
Transformer oil testing apparatus
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated
terminals
TO FIND ABCD, HYBRID & IMAGE PARAMETERS OF A
MODEL OF TRANSMISSION LINE

*
*
*
*
*
*
*
*
*

Diagrammatic representation on concept on the panel


On board built in digitals meters
Indicating lights
Onboard Digital Voltmeter - 02 Nos.
Onboard Digital Ammeter - 02 Nos.
Onboard Power factor meter
Lamp Load
Facility to calculate ABCD & Hybrid parameter experiment
Onboard Inductive Load

*
*
*
*
*
*
*
8.

Onboard Capacitive Load


Onboard Resistive Load
Onboard Wattmeter
Single phase auto transformer 0-270V
DP Switch
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated
terminals
TO STUDY PERFORMANCE OF A TRANSMISSION LINE
UNDER NO LOAD CONDITION & UNDER LOAD AT
DIFFERENT POWER FACTORS
TO OBSERVE THE FERRANTI EFFECT IN A MODEL OF
TRANSMISSION LINE

9.

FOR EXPERIMENT NO. 8 & 9


*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
10.

Diagrammatic representation on concept on the panel


On board built in digitals meters
Indicating lights
Onboard Digital Voltmeter - 02 Nos.
Onboard Digital Ammeter - 02 Nos.
Lamp Load
Facility to perform Ferranti Effect experiment
Facility to calculate study performance of a transmission line
under
No load condition & under load at different power factors
Onboard Inductive Load
Onboard Capacitive Load
Onboard Resistive Load
Onboard Wattmeter
Single phase auto transformer 0-270V -02Nos.
DP Switch
Rotary switch
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated
terminals
TO STUDY PERFORMANCE CHARACTERISTICS OF TYPICAL
DC DISTRIBUTION SYSTEM IN RADIAL AND RING MAIN
CONFIGURATION
TO STUDY RADIAL FEEDER PERFORMANCE WHEN
A) FED AT ONE END B) FED AT BOTH ENDS

12.

FOR EXPERIMENT NO. 10 & 12


*
*
*
*
*
*
*
*
*
*

11.

Diagrammatic representation on concept on the panel


On board built in digitals meters
Indicating lights
Onboard Digital Ammeter
Onboard Digital Voltmeter
Dc distribution network operated on 110V/2A
Facility to connect the network in Ring & radial configuration
Double pole MCB (Mini Circuit Breaker) for input
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated terminals

TO STUDY CHARACTERISTICS OF MCB & HRC FUSE


* Diagrammatic representation on concept on the panel

*
*
*
*
*
*
*
*
*
*

On board built in digitals meters


Indicating lights
Onboard Digital Ammeter AC 0-20A
Rheostat- 38ohm - 8.5A
Single phase auto transformer 230V/10A
Onboard Digital Timer with Start and Stop facility
DP Switch
MCB (Mini Circuit Breaker) and HRC fuse
User's Manual with patch cords.
Educational standard 4mm wire connector and insulated terminals

S-ar putea să vă placă și