4046 E
10
11
12
series:
IFPM = INTERNORMEN-Fluid Purifier Systems, mobile
nominal size: 71
sealing material:
V
= Viton (FPM)
pump unit:
P23
= pump unit 23, NG 80.50
motor:
D01
= B5/90L/4.1,8.1800.265/460.D.60.1.-.-.rotary current motor 265/460 V, 60 Hz, approx. 1700 RPM, 2.4 HP, protection IP 55
10
vacuum pump:
VP07 = vacuum pump 07, 265/460 V, 3-phase, 60 Hz, 2.0 HP, protection IP 55
11
clogging sensor:
VS1
= VS1.1,5.V.-. GS.B.E electronical, at p1 and p2, 22 PSI, see sheet-no. 1607
12
supply voltage:
B
= 480V, 3-phase
series:
01NR. =
EDV 08/12
info-internormen@eaton.com
www.eaton.com/filtration
2. Description:
2.1. Effects of Water Contamination:
Water is one of the most common contaminants and the second most destructive besides particulate contamination. Some of the most damaging problems water contamination can cause are:
Fluid breakdown
- Additive depletion
- Reduction of the lubrication properties of the fluid
- Oil oxidation
Internal corrosion
Abrasive wear in system components
Reduced dielectric strength
3. Technical data:
Inlet connection:
Outlet connection:
Circulation flow rate: *
Operating vacuum:**
E-motor hydraulic pump:
E-motor vacuum pump:
Heater capacity:
Filter type:
Seal material:
Maximum viscosity:
Water extraction rate:***
Ambient temperature:
Fluid temperature:
weight:
*
**
***
US 4046 E
4. Test methods: