DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5/7SD522

02.04.11 19:00:38

DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5


MLFB: 7SD52215NB997HJ4
Parameter set version: V04.61.04
Device path: C:\Siemens\Digsi4\D4PROJ\Dewa\P7DI\GV\SD\00000037
Author:
Creation date: 30.03.11 08:56:26
Last modified: 02.04.11 18:49:12
Operating mode: Offline
Comment:
Setting values in: Secondary value description

PRINT - CONTENTS
1 Configuration - short (column-oriented)
1.1 Binary inputs
1.2 Binary outputs
1.3 LEDs
1.4 CFC
1.5 System interface IEC 61850

2
2
2
2
3
4

Page 1 of 10

SIMATIC

DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5/7SD522

02.04.11 19:00:38

1 Configuration - short (column-oriented)


1.1 Binary inputs
Binary
inputs

No.

Group

Information

Type Configuration

P.System Data 2 >Control & Indication Circuit DC Fail

SP

P.System Data 2 >Main-2 Protection Fail

SP

P.System Data 2 > CB contact (52a) - R phase

SP

P.System Data 2 > CB contact (52a) - Y phase

SP

P.System Data 2 > CB contact (52a) - B phase

SP

00380 P.System Data 2 >CB aux. contact 3pole Open

SP

00411 P.System Data 2 >CB1 aux. 3p Open (for AR, CB-Test)

SP

P.System Data 2 >CB Open command received

SP

Breaker Failure

SP

P.System Data 2 >VT MCB Tripped

SP

10

P.System Data 2 >Trip Coil -1 faulty

SP

11

Remote Signals

SP

>CBF INITIATED BY BUSBAR PROTECTION

>InterTRIP SEND(IS3) - M1Reactor protn.

1.2 Binary outputs


BO

No.

Group

Information

Type Configuration

03229 Prot. Interface

Prot Int 1: Reception of faulty data

OUT U

03230 Prot. Interface

Prot Int 1: Total receiption failure

OUT U

03233 Prot. Interface

Device table has inconsistent numbers

OUT U

03234 Prot. Interface

Device tables are unequal

OUT U

03235 Prot. Interface

Differences between common parameters

OUT U

03239 Prot. Interface

Prot Int 1: Transmission delay too high

OUT U

03258 Prot. Interface

ProtInt1:Permissible error rate exceeded

OUT U

03487 Diff.-Topo

Equal IDs in constellation

OUT U

>VT MCB Tripped

SP

P.System Data 2

00167 Measurem.Superv Failure: Voltage Balance

OUT U

00168 Measurem.Superv Failure: Voltage absent

OUT U

00169 Measurem.Superv VT Fuse Failure (alarm >10s)

OUT U

00170 Measurem.Superv VT Fuse Failure (alarm instantaneous)

OUT U

00511 P.System Data 2

Relay GENERAL TRIP command

OUT U

01476 Breaker Failure

BF Trip T1 (local trip) - 3pole

OUT U

01494 Breaker Failure

BF Trip T2 (busbar trip)

OUT U

01494 Breaker Failure

BF Trip T2 (busbar trip)

OUT U

01494 Breaker Failure

BF Trip T2 (busbar trip)

OUT U

>Control & Indication Circuit DC Fail

SP

P.System Data 2

00511 P.System Data 2

Relay GENERAL TRIP command

OUT U

01476 Breaker Failure

BF Trip T1 (local trip) - 3pole

OUT U

01494 Breaker Failure

BF Trip T2 (busbar trip)

OUT U

10 00290 Measurem.Superv Alarm: Broken current-wire detected L1

OUT U

10 00291 Measurem.Superv Alarm: Broken current-wire detected L2

OUT U

10 00292 Measurem.Superv Alarm: Broken current-wire detected L3

OUT U

11 01494 Breaker Failure

BF Trip T2 (busbar trip)

OUT U

13 00051 Device

Device is Operational and Protecting

OUT U

20 03141 Diff. Prot

Diff: General TRIP

OUT U

20 03517 Intertrip

I.Trip: General TRIP

OUT U

20 04435 DTT Direct Trip

DTT TRIP command L123

OUT U

20 01476 Breaker Failure

BF Trip T1 (local trip) - 3pole

OUT U

Trip Extension to CB

SP

21 03141 Diff. Prot

Diff: General TRIP

OUT U

21 03517 Intertrip

I.Trip: General TRIP

OUT U

21 04435 DTT Direct Trip

DTT TRIP command L123

OUT U

21 01476 Breaker Failure

BF Trip T1 (local trip) - 3pole

OUT U

Trip Extension to CB

SP

22 03141 Diff. Prot

Diff: General TRIP

OUT U

22 03517 Intertrip

I.Trip: General TRIP

OUT U

22 04435 DTT Direct Trip

DTT TRIP command L123

OUT U

22 01476 Breaker Failure

BF Trip T1 (local trip) - 3pole

OUT U

Trip Extension to CB

SP

20

21

22

User-def.

User-def.

User-def.

Page 2 of 10

SIMATIC

DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5/7SD522

02.04.11 19:00:38

1.3 LEDs
LEDs

No.

Group

Information

Type Configuration

00511 P.System Data 2

Relay GENERAL TRIP command

OUT L

01476 Breaker Failure

BF Trip T1 (local trip) - 3pole

OUT L

01494 Breaker Failure

BF Trip T2 (busbar trip)

OUT L

00503 P.System Data 2

Relay PICKUP Phase L1

OUT U

P.System Data 2

Relay Trip L1

SP

00504 P.System Data 2

Relay PICKUP Phase L2

OUT U

Relay Trip L2

SP

Relay PICKUP Phase L3

OUT U

P.System Data 2

00505 P.System Data 2

P.System Data 2

L
L

Relay Trip L3

SP

03141 Diff. Prot

Diff: General TRIP

OUT L

10

01494 Breaker Failure

BF Trip T2 (busbar trip)

OUT L

11

04435 DTT Direct Trip

DTT TRIP command L123

OUT L

12

03229 Prot. Interface

Prot Int 1: Reception of faulty data

OUT U

12

03230 Prot. Interface

Prot Int 1: Total receiption failure

OUT U

12

03233 Prot. Interface

Device table has inconsistent numbers

OUT U

12

03234 Prot. Interface

Device tables are unequal

OUT U

12

03235 Prot. Interface

Differences between common parameters

OUT U

12

03239 Prot. Interface

Prot Int 1: Transmission delay too high

OUT U

12

03258 Prot. Interface

ProtInt1:Permissible error rate exceeded

OUT U

12

03487 Diff.-Topo

Equal IDs in constellation

OUT U

>VT MCB Tripped

SP

P.System Data 2

13

13

00167 Measurem.Superv Failure: Voltage Balance

OUT U

13

00168 Measurem.Superv Failure: Voltage absent

OUT U

13

00169 Measurem.Superv VT Fuse Failure (alarm >10s)

OUT U

13

00170 Measurem.Superv VT Fuse Failure (alarm instantaneous)

OUT U

13

00290 Measurem.Superv Alarm: Broken current-wire detected L1

OUT U

13

00291 Measurem.Superv Alarm: Broken current-wire detected L2

OUT U

13

00292 Measurem.Superv Alarm: Broken current-wire detected L3

OUT U

14

P.System Data 2

>Control & Indication Circuit DC Fail

SP

1.4 CFC
No.

Group

00016 Device

Information

Source Destination

>DataStop / >Stop data transmission

Device

UnlockDT / Unlock data transmission via BI

Device

Reset LED / Reset LED

Device

Brk OPENED / Breaker OPENED

Device

FdrEARTHED / Feeder EARTHED

00380 P.System Data 2

>CB 3p Open / >CB aux. contact 3pole Open

00503 P.System Data 2

Relay PICKUP L1 / Relay PICKUP Phase L1

00504 P.System Data 2

Relay PICKUP L2 / Relay PICKUP Phase L2

00505 P.System Data 2

Relay PICKUP L3 / Relay PICKUP Phase L3

00511 P.System Data 2

Relay TRIP / Relay GENERAL TRIP command

P.System Data 2

>CB 52a-R / > CB contact (52a) - R phase

P.System Data 2

>CB 52a-Y / > CB contact (52a) - Y phase

P.System Data 2

>CB 52a-B / > CB contact (52a) - B phase

P.System Data 2

>L1 Trip / Relay Trip L1

P.System Data 2

>L2 Trip / Relay Trip L2

P.System Data 2

>L3 Trip / Relay Trip L3

P.System Data 2

>VTMCBTR / >VT MCB Tripped

P.System Data 2

VT Prot Op / VT Protection Operated

P.System Data 2

Comms Fail / Communication Fail

P.System Data 2

ITR.Send / Intertrip Send

03141 Diff. Prot

Diff. Gen. TRIP / Diff: General TRIP

03190 Diff. Prot

Test Diff. / Diff: Set Teststate of Diff. protection

03517 Intertrip

ITrp. Gen. TRIP / I.Trip: General TRIP

X
X
X

Remote Signals

>DIST CS / >Distance Carrier Send

Remote Signals

>IS3 Send / >InterTRIP SEND(IS3) - M1Reactor protn.

Remote Signals

>DIST CR / >Distance Carrier Receive

Remote Signals

> IR3 Recieved / > IR3 Rec- M1RP Trip

Remote Signals

>CBF ITR send / >CBF Intertrip Send IS1

Remote Signals

>DEF CS / > DEF Carrier Send

Remote Signals

>CBF ITR RCV / >CBF Intertrip received IR1

Page 3 of 10

SIMATIC
No.

DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5/7SD522


Group

Remote Signals

Information
>DTT Trip L123 / >Direct Transfer Trip INPUT 3ph L123

04435 DTT Direct Trip

DTT TRIP L123 / DTT TRIP command L123

DTT Direct Trip

Source Destination

>DEF CR / >DEF Carrier Receive

04417 DTT Direct Trip

X
X
X

>ITR Recv / >Intertrip Received Indication IR1

07104 Back-Up O/C

>BLOCK O/C I>> / >BLOCK Backup OverCurrent I>>

07191 Back-Up O/C

O/C PICKUP I>> / Backup O/C Pickup I>>

00168 Measurem.Superv Fail U absent / Failure: Voltage absent

00169 Measurem.Superv VT FuseFail>10s / VT Fuse Failure (alarm >10s)

00170 Measurem.Superv VT FuseFail / VT Fuse Failure (alarm instantaneous)

00290 Measurem.Superv Broken Iwire L1 / Alarm: Broken current-wire detected L1

00291 Measurem.Superv Broken Iwire L2 / Alarm: Broken current-wire detected L2

00292 Measurem.Superv Broken Iwire L3 / Alarm: Broken current-wire detected L3

Measurem.Superv CT Fail / CT Fail

01307 Earth Fault O/C

>EF BLOCK 3I0>> / >Earth Fault O/C Block 3I0>>

01310 Earth Fault O/C

>EF InstTRIP / >Earth Fault O/C Instantaneous trip

01355 Earth Fault O/C

EF 3I0>> Pickup / E/F 3I0>> PICKED UP

01369 Earth Fault O/C

EF 3I0p TRIP / E/F 3I0p TRIP

01415 Breaker Failure

>BF Start 3pole / >BF: External start 3pole

01476 Breaker Failure

BF T1-TRIP L123 / BF Trip T1 (local trip) - 3pole

01494 Breaker Failure

BF T2-TRIP(bus) / BF Trip T2 (busbar trip)

>BB-CBFINI / >CBF INITIATED BY BUSBAR PROTECTION

03229 Prot. Interface

PI1 Data fault / Prot Int 1: Reception of faulty data

03230 Prot. Interface

PI1 Datafailure / Prot Int 1: Total receiption failure

03233 Prot. Interface

DT inconsistent / Device table has inconsistent numbers

03234 Prot. Interface

DT unequal / Device tables are unequal

03235 Prot. Interface

Par. different / Differences between common parameters

03239 Prot. Interface

PI1 TD alarm / Prot Int 1: Transmission delay too high

03256 Prot. Interface

PI1 unsym. / Prot.1: Delay time unsymmetry to large

03258 Prot. Interface

PI1 Error / ProtInt1:Permissible error rate exceeded

03484 Diff.-Topo

Logout / Local activation of Logout state

03487 Diff.-Topo

Breaker Failure

X
X
X

X
X

Equal IDs / Equal IDs in constellation

Control Device

Breaker / Breaker

Control Device

Breaker / Breaker

Control Device

Disc.Swit. / Disconnect Switch

Control Device

Disc.Swit. / Disconnect Switch

Control Device

EarthSwit / Earth Switch

Control Device

EarthSwit / Earth Switch

Control Device

Brk Open / Interlocking: Breaker Open

Control Device

Brk Close / Interlocking: Breaker Close

Control Device

Disc.Open / Interlocking: Disconnect switch Open

Control Device

Disc.Close / Interlocking: Disconnect switch Close

Control Device

E Sw Open / Interlocking: Earth switch Open

Control Device

E Sw Cl. / Interlocking: Earth switch Close

Process Data

>Door open / >Cabinet door open

Process Data

>CB wait / >CB waiting for Spring charged

00601 Measurement

IL1 = / I L1

00602 Measurement

IL2 = / I L2

00603 Measurement

IL3 = / I L3

Set Points(MV)
00285 Set Points(MV)

02.04.11 19:00:38

PF< / Lower setting limit for Power Factor

cosphi alarm / Power factor alarm

User-def.

Trip Ext / Trip Extension to CB

User-def.

I<5% / I<5%

Page 4 of 10

SIMATIC

DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5/7SD522

02.04.11 19:00:38

1.5 System interface IEC 61850


No.

Group

Information

Type

Source Destination Extended

Assigned IEC 61850 object (LD /


LN / DO)

Device

Test mode

IntSP

PROT/LLN0/Mod
PROT/LLN0/Beh
PROT/LPHD1/Proxy
PROT/PDIS1/Beh
PROT/PDIS1/Str
PROT/PDIS1/StrAG
PROT/PDIS1/StrBG
PROT/PDIS1/StrCG
PROT/PDIS1/StrAB
PROT/PDIS1/StrBC

Device

Stop data transmission

IntSP

PROT/LLN0/Mod
PROT/LLN0/Beh
PROT/PDIS1/Beh
PROT/PDIS2/Beh
PROT/PDIS3/Beh
PROT/PDIS4/Beh
PROT/PDIS5/Beh
PROT/PDIS10/Beh
PROT/PSCH1/Beh
PROT/PSDE1/Beh

00051 Device

Device is Operational and Protecting

OUT

PROT/LLN0/Health
PROT/LPHD1/PhyHealth
PROT/PDIS1/Health
PROT/PDIS2/Health
PROT/PDIS3/Health
PROT/PDIS4/Health
PROT/PDIS5/Health
PROT/PDIS10/Health
PROT/PSCH1/Health
PROT/PSDE1/Health

00052 Device

At Least 1 Protection Funct. is Active

IntSP

PROT/LLN0/Mod
PROT/LLN0/Beh
PROT/PDIS1/Beh
PROT/PDIS2/Beh
PROT/PDIS3/Beh
PROT/PDIS4/Beh
PROT/PDIS5/Beh

00055 Device

Reset Device

OUT

PROT/LPHD1/Proxy
PROT/XCBR1/Loc
PROT/XCBR1/BlkOpn
PROT/XCBR1/BlkCls
PROT/XCBR2/Loc
PROT/XCBR2/BlkOpn
PROT/XCBR2/BlkCls
PROT/XCBR3/Loc
PROT/XCBR3/BlkOpn
PROT/XCBR3/BlkCls

00056 Device

Initial Start of Device

OUT

CTRL/LPHD1/DevStr

Reset LED

IntSP

CTRL/LLN0/LEDRs

00067 Device

Resume

OUT

CTRL/LPHD1/DevStr

00140 Device

Error with a summary alarm

OUT

CTRL/CALH1/GrAlm

00160 Device

Alarm Summary Event

OUT

CTRL/CALH1/GrWrn

00183 Device

Error Board 1

OUT

CTRL/LLN0/Health
CTRL/CALH1/ErrBoard1

00184 Device

Error Board 2

OUT

CTRL/LLN0/Health
CTRL/CALH1/ErrBoard2

00185 Device

Error Board 3

OUT

CTRL/LLN0/Health
CTRL/CALH1/ErrBoard3

00186 Device

Error Board 4

OUT

CTRL/LLN0/Health
CTRL/CALH1/ErrBoard4

00187 Device

Error Board 5

OUT

CTRL/LLN0/Health
CTRL/CALH1/ErrBoard5

00188 Device

Error Board 6

OUT

CTRL/LLN0/Health
CTRL/CALH1/ErrBoard6

00189 Device

Error Board 7

OUT

CTRL/LLN0/Health
CTRL/CALH1/ErrBoard7

30053 Osc. Fault Rec.

Fault recording is running

OUT

DR/RDRE1/RcdMade
DR/RDRE1/RcdStr

00379 P.System Data 2

>CB aux. contact 3pole Closed

SP

PROT/XCBR1/Pos

00380 P.System Data 2

>CB aux. contact 3pole Open

SP

PROT/XCBR1/Pos

00501 P.System Data 2

Relay PICKUP

OUT

PROT/PTRC1/Str

00503 P.System Data 2

Relay PICKUP Phase L1

OUT

PROT/PTRC1/Str

00504 P.System Data 2

Relay PICKUP Phase L2

OUT

PROT/PTRC1/Str

Device

Page 5 of 10

SIMATIC
No.

DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5/7SD522


Group

Information

Type

Source Destination Extended

02.04.11 19:00:38
Assigned IEC 61850 object (LD /
LN / DO)

00505 P.System Data 2

Relay PICKUP Phase L3

OUT

PROT/PTRC1/Str

00506 P.System Data 2

Relay PICKUP Earth

OUT

PROT/PTRC1/Str

00507 P.System Data 2

Relay TRIP command Phase L1

OUT

PROT/PTRC1/Tr

00508 P.System Data 2

Relay TRIP command Phase L2

OUT

PROT/PTRC1/Tr

00509 P.System Data 2

Relay TRIP command Phase L3

OUT

00511 P.System Data 2

Relay GENERAL TRIP command

OUT

00536 P.System Data 2

Relay Definitive TRIP

OUT

PROT/PTRC1/FinTr

P.System Data 2

>Control & Indication Circuit DC Fail

SP

CTRL/CIDCFLGGIO1/SPCSO1

P.System Data 2

>Main-2 Protection Fail

SP

CTRL/M2FAILGGIO1/SPCSO1

P.System Data 2

>CB Open command received

SP

CTRL/CBOPCDGGIO1/SPCSO1

P.System Data 2

>Trip Coil -1 faulty

SP

CTRL/TC1FLTGGIO1/SPCSO1

P.System Data 2

>VT MCB Tripped

SP

CTRL/VTMCBTGGIO1/SPCSO1

P.System Data 2

VT Protection Operated

SP

CTRL/VTPROTGGIO1/SPCSO1

P.System Data 2

Communication Fail

SP

CTRL/COMFLTGGIO1/SPCSO1

P.System Data 2

Intertrip Send

SP

CTRL/ITRSDGGIO1/SPCSO1

03120 Diff. Prot

Diff: Active

OUT

PROT/PDIF1/Mod
PROT/PDIF1/Beh
PROT/PDIF2/Mod
PROT/PDIF2/Beh
PROT/PTRC3/Mod
PROT/PTRC3/Beh

03132 Diff. Prot

Diff: Fault detection

OUT

PROT/PTRC3/Str

03133 Diff. Prot

Diff: Fault detection in phase L1

OUT

PROT/PTRC3/Str

03134 Diff. Prot

Diff: Fault detection in phase L2

OUT

PROT/PTRC3/Str

03135 Diff. Prot

Diff: Fault detection in phase L3

OUT

PROT/PTRC3/Str

03136 Diff. Prot

Diff: Earth fault detection

OUT

PROT/PTRC3/Str

03137 Diff. Prot

Diff: Fault detection of I-Diff>>

OUT

PROT/PDIF2/Str

03139 Diff. Prot

Diff: Fault detection of I-Diff>

OUT

03141 Diff. Prot

Diff: General TRIP

OUT

03145 Diff. Prot

Diff: TRIP L123

OUT

PROT/PTRC3/Op

03148 Diff. Prot

Diff: Differential protection is blocked

OUT

PROT/PDIF1/Mod
PROT/PDIF1/Beh
PROT/PDIF2/Mod
PROT/PDIF2/Beh
PROT/PTRC3/Mod
PROT/PTRC3/Beh

03149 Diff. Prot

Diff: Diff. protection is switched off

OUT

PROT/PDIF1/Mod
PROT/PDIF1/Beh
PROT/PDIF2/Mod
PROT/PDIF2/Beh
PROT/PTRC3/Mod
PROT/PTRC3/Beh

03176 Diff. Prot

Diff: Fault detection L1 (only)

OUT

PROT/PTRC3/StrA

03177 Diff. Prot

Diff: Fault detection L1E

OUT

PROT/PTRC3/StrAG

03178 Diff. Prot

Diff: Fault detection L2 (only)

OUT

PROT/PTRC3/StrB

03179 Diff. Prot

Diff: Fault detection L2E

OUT

PROT/PTRC3/StrBG

03180 Diff. Prot

Diff: Fault detection L12

OUT

PROT/PTRC3/StrAB

03181 Diff. Prot

Diff: Fault detection L12E

OUT

PROT/PTRC3/StrABG

03182 Diff. Prot

Diff: Fault detection L3 (only)

OUT

PROT/PTRC3/StrC

03183 Diff. Prot

Diff: Fault detection L3E

OUT

PROT/PTRC3/StrCG

03184 Diff. Prot

Diff: Fault detection L31

OUT

PROT/PTRC3/StrCA

03185 Diff. Prot

Diff: Fault detection L31E

OUT

PROT/PTRC3/StrCAG

03186 Diff. Prot

Diff: Fault detection L23

OUT

PROT/PTRC3/StrBC

03187 Diff. Prot

Diff: Fault detection L23E

OUT

PROT/PTRC3/StrBCG

03188 Diff. Prot

Diff: Fault detection L123

OUT

PROT/PTRC3/StrABC

03189 Diff. Prot

Diff: Fault detection L123E

OUT

PROT/PTRC3/StrABCG

03190 Diff. Prot

Diff: Set Teststate of Diff. protection

IntSP

PROT/PDIF1/Mod
PROT/PDIF1/Beh
PROT/PDIF1/Str
PROT/PDIF1/Op
PROT/PDIF2/Mod
PROT/PDIF2/Beh
PROT/PDIF2/Str
PROT/PDIF2/Op
PROT/PTRC3/Mod
PROT/PTRC3/Beh

PROT/PTRC1/Tr
X

PROT/PTRC1/Tr

PROT/PDIF1/Str
X

PROT/PTRC3/Op

Page 6 of 10

SIMATIC
No.

DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5/7SD522


Group

Information

Type

03193 Diff. Prot

Diff: Commissioning state is active

OUT

03517 Intertrip

Source Destination Extended


X

02.04.11 19:00:38
Assigned IEC 61850 object (LD /
LN / DO)
PROT/PDIF1/Mod
PROT/PDIF1/Beh
PROT/PDIF1/Str
PROT/PDIF1/Op
PROT/PDIF2/Mod
PROT/PDIF2/Beh
PROT/PDIF2/Str
PROT/PDIF2/Op
PROT/PTRC3/Mod
PROT/PTRC3/Beh

I.Trip: General TRIP

OUT

Remote Signals

>Distance Carrier Send

SP

Remote Signals

>InterTRIP SEND(IS3) - M1Reactor protn.

SP

Remote Signals

>Distance Carrier Receive

OUT

Remote Signals

> IR3 Rec- M1RP Trip

OUT

Remote Signals

>CBF Intertrip Send IS1

SP

Remote Signals

> DEF Carrier Send

SP

Remote Signals

>CBF Intertrip received IR1

OUT

Remote Signals

>DEF Carrier Receive

OUT

04417 DTT Direct Trip

>Direct Transfer Trip INPUT 3ph L123

SP

04435 DTT Direct Trip

DTT TRIP command L123

OUT

>Intertrip Received Indication IR1

SP

CTRL/ITRRECGGIO1/SPCSO1

07104 Back-Up O/C

>BLOCK Backup OverCurrent I>>

SP

PROT/PTOC3/Mod
PROT/PTOC3/Beh

07105 Back-Up O/C

>BLOCK Backup OverCurrent I>

SP

PROT/PTOC2/Mod
PROT/PTOC2/Beh

07106 Back-Up O/C

>BLOCK Backup OverCurrent Ip

SP

PROT/PTOC1/Mod
PROT/PTOC1/Beh

07130 Back-Up O/C

>BLOCK I-STUB

SP

PROT/PTOC4/Mod
PROT/PTOC4/Beh

07131 Back-Up O/C

>Enable I-STUB-Bus function

SP

PROT/PTOC4/Mod
PROT/PTOC4/Beh

07151 Back-Up O/C

Backup O/C is switched OFF

OUT

PROT/PTOC1/Mod
PROT/PTOC1/Beh
PROT/PTOC2/Mod
PROT/PTOC2/Beh
PROT/PTOC3/Mod
PROT/PTOC3/Beh
PROT/PTOC4/Mod
PROT/PTOC4/Beh
PROT/PTOC9/Mod
PROT/PTOC9/Beh

07152 Back-Up O/C

Backup O/C is BLOCKED

OUT

PROT/PTOC1/Mod
PROT/PTOC1/Beh
PROT/PTOC2/Mod
PROT/PTOC2/Beh
PROT/PTOC3/Mod
PROT/PTOC3/Beh
PROT/PTOC4/Mod
PROT/PTOC4/Beh
PROT/PTOC9/Mod
PROT/PTOC9/Beh

07153 Back-Up O/C

Backup O/C is ACTIVE

OUT

PROT/PTOC1/Mod
PROT/PTOC1/Beh
PROT/PTOC2/Mod
PROT/PTOC2/Beh
PROT/PTOC3/Mod
PROT/PTOC3/Beh
PROT/PTOC4/Mod
PROT/PTOC4/Beh
PROT/PTOC9/Mod
PROT/PTOC9/Beh

07191 Back-Up O/C

Backup O/C Pickup I>>

OUT

PROT/PTOC3/Str

07192 Back-Up O/C

Backup O/C Pickup I>

OUT

PROT/PTOC2/Str

07193 Back-Up O/C

Backup O/C Pickup Ip

OUT

PROT/PTOC1/Str

07201 Back-Up O/C

O/C I-STUB Pickup

OUT

PROT/PTOC4/Str

07221 Back-Up O/C

Backup O/C TRIP I>>

OUT

PROT/PTOC3/Op

07222 Back-Up O/C

Backup O/C TRIP I>

OUT

PROT/PTOC2/Op

07223 Back-Up O/C

Backup O/C TRIP Ip

OUT

PROT/PTOC1/Op

07235 Back-Up O/C

O/C I-STUB TRIP

OUT

DTT Direct Trip

PROT/PTOC4/Op

00161 Measurem.Superv Failure: General Current Supervision

OUT

00163 Measurem.Superv Failure: Current Balance

OUT

Page 7 of 10

SIMATIC
No.

DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5/7SD522


Group

Information

Type

Source Destination Extended

02.04.11 19:00:38
Assigned IEC 61850 object (LD /
LN / DO)

00164 Measurem.Superv Failure: General Voltage Supervision

OUT

00167 Measurem.Superv Failure: Voltage Balance

OUT

00168 Measurem.Superv Failure: Voltage absent

OUT

00169 Measurem.Superv VT Fuse Failure (alarm >10s)

OUT

00170 Measurem.Superv VT Fuse Failure (alarm instantaneous)

OUT

00296 Measurem.Superv Current summation superv is switched OFF

OUT

00290 Measurem.Superv Alarm: Broken current-wire detected L1

OUT

PROT/PDIF3/Mod
PROT/PDIF3/Beh

00291 Measurem.Superv Alarm: Broken current-wire detected L2

OUT

PROT/PDIF3/Mod
PROT/PDIF3/Beh

00292 Measurem.Superv Alarm: Broken current-wire detected L3

OUT

PROT/PDIF3/Mod
PROT/PDIF3/Beh

Measurem.Superv CT Fail

SP

CTRL/CTFAILGGIO1/SPCSO1

01305 Earth Fault O/C

>Earth Fault O/C Block 3I0>>>

SP

PROT/PTOC7/Mod
PROT/PTOC7/Beh

01307 Earth Fault O/C

>Earth Fault O/C Block 3I0>>

SP

PROT/PTOC6/Mod
PROT/PTOC6/Beh

01308 Earth Fault O/C

>Earth Fault O/C Block 3I0>

SP

PROT/PTOC5/Mod
PROT/PTOC5/Beh

01309 Earth Fault O/C

>Earth Fault O/C Block 3I0p

SP

PROT/PTOC8/Mod
PROT/PTOC8/Beh

01331 Earth Fault O/C

Earth fault protection is switched OFF

OUT

PROT/PTOC5/Mod
PROT/PTOC5/Beh
PROT/PTOC6/Mod
PROT/PTOC6/Beh
PROT/PTOC7/Mod
PROT/PTOC7/Beh
PROT/PTOC8/Mod
PROT/PTOC8/Beh

01332 Earth Fault O/C

Earth fault protection is BLOCKED

OUT

PROT/PTOC5/Mod
PROT/PTOC5/Beh
PROT/PTOC6/Mod
PROT/PTOC6/Beh
PROT/PTOC7/Mod
PROT/PTOC7/Beh
PROT/PTOC8/Mod
PROT/PTOC8/Beh

01333 Earth Fault O/C

Earth fault protection is ACTIVE

OUT

PROT/PTOC5/Mod
PROT/PTOC5/Beh
PROT/PTOC6/Mod
PROT/PTOC6/Beh
PROT/PTOC7/Mod
PROT/PTOC7/Beh

01354 Earth Fault O/C

E/F 3I0>>> PICKED UP

OUT

PROT/PTOC7/Str

01355 Earth Fault O/C

E/F 3I0>> PICKED UP

OUT

PROT/PTOC6/Str

01356 Earth Fault O/C

E/F 3I0> PICKED UP

OUT

PROT/PTOC5/Str

01357 Earth Fault O/C

E/F 3I0p PICKED UP

OUT

PROT/PTOC8/Str

01358 Earth Fault O/C

E/F picked up FORWARD

OUT

PROT/PTOC5/Str
PROT/PTOC6/Str
PROT/PTOC7/Str
PROT/PTOC8/Str
PROT/PTRC1/Str

01359 Earth Fault O/C

E/F picked up REVERSE

OUT

PROT/PTOC5/Str
PROT/PTOC6/Str
PROT/PTOC7/Str
PROT/PTOC8/Str
PROT/PTRC1/Str

01366 Earth Fault O/C

E/F 3I0>>> TRIP

OUT

PROT/PTOC7/Op

01367 Earth Fault O/C

E/F 3I0>> TRIP

OUT

PROT/PTOC6/Op

01368 Earth Fault O/C

E/F 3I0> TRIP

OUT

PROT/PTOC5/Op

01369 Earth Fault O/C

E/F 3I0p TRIP

OUT

PROT/PTOC8/Op

01120 Fault Locator

Flt Locator: Distance [%] to fault

VI

PROT/RFLO1/FltDisPrc

01133 Fault Locator

Fault locator setting error K0,angle(K0)

OUT

PROT/RFLO1/Health

01111 Fault Locator

Fault locator active

OUT

PROT/RFLO1/Mod
PROT/RFLO1/Beh

01451 Breaker Failure

Breaker failure is switched OFF

OUT

PROT/RBRF1/Mod
PROT/RBRF1/Beh

01452 Breaker Failure

Breaker failure is BLOCKED

OUT

PROT/RBRF1/Mod
PROT/RBRF1/Beh

01461 Breaker Failure

Breaker failure protection started

OUT

PROT/RBRF1/Str

01476 Breaker Failure

BF Trip T1 (local trip) - 3pole

OUT

PROT/RBRF1/OpIn

Page 8 of 10

SIMATIC
No.

DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5/7SD522


Group

Information

Type

Source Destination Extended


X

02.04.11 19:00:38
Assigned IEC 61850 object (LD /
LN / DO)

01494 Breaker Failure

BF Trip T2 (busbar trip)

OUT

03229 Prot. Interface

Prot Int 1: Reception of faulty data

OUT

PROT/RBRF1/OpEx

03230 Prot. Interface

Prot Int 1: Total receiption failure

OUT

03233 Prot. Interface

Device table has inconsistent numbers

OUT

03234 Prot. Interface

Device tables are unequal

OUT

03235 Prot. Interface

Differences between common parameters

OUT

03239 Prot. Interface

Prot Int 1: Transmission delay too high

OUT

03258 Prot. Interface

ProtInt1:Permissible error rate exceeded

OUT

03487 Diff.-Topo

Equal IDs in constellation

OUT

03491 Diff.-Topo

Relay 1 in Login state

OUT

MEAS/MMXU2/Mod
MEAS/MMXU2/Beh

03492 Diff.-Topo

Relay 2 in Login state

OUT

MEAS/MMXU3/Mod
MEAS/MMXU3/Beh

Cntrl Authority

Control Authority

IntSP

CTRL/LLN0/Loc

Control Device

Breaker

CF_D12 X

Control Device

Breaker

DP

Control Device

Disconnect Switch

CF_D2

Control Device

Disconnect Switch

DP

Control Device

Earth Switch

CF_D2

Control Device

Earth Switch

DP

Control Device

Q2 Open/Close

CF_D2

Control Device

Q2 Open/Close

DP

Control Device

Q9 Open/Close

CF_D2

Control Device

Q9 Open/Close

DP

CTRL/Q9XSWI1
CTRL/Q9CSWI1
Disconnector
Q9 OpCnt=

00601 Measurement

I L1

MV

MEAS/MMXU1/A

00602 Measurement

I L2

MV

MEAS/MMXU1/A

00603 Measurement

I L3

MV

MEAS/MMXU1/A

00610 Measurement

3I0 (zero sequence)

MV

MEAS/MMXU1/A
MEAS/MSQI1/SeqA

00619 Measurement

I1 (positive sequence)

MV

MEAS/MSQI1/SeqA

00620 Measurement

I2 (negative sequence)

MV

MEAS/MSQI1/SeqA

00644 Measurement

Frequency

MV

MEAS/MMXU1/Hz

00621 Measurement

U L1-E

MV

MEAS/MMXU1/PhV

00622 Measurement

U L2-E

MV

MEAS/MMXU1/PhV

00623 Measurement

U L3-E

MV

MEAS/MMXU1/PhV

00624 Measurement

U L12

MV

MEAS/MMXU1/PPV

00625 Measurement

U L23

MV

MEAS/MMXU1/PPV

00626 Measurement

U L31

MV

MEAS/MMXU1/PPV

00684 Measurement

U0 (zero sequence)

MV

MEAS/MSQI1/SeqV

00634 Measurement

U1 (positive sequence)

MV

MEAS/MSQI1/SeqV

CTRL/Q0XCBR1
CTRL/Q0CSWI1
Circuit breaker
Q0 OpCnt=
X

CTRL/Q0XCBR1
CTRL/Q0CSWI1
Circuit breaker
Q0 OpCnt=
CTRL/Q1XSWI1
CTRL/Q1CSWI1
Disconnector
Q1 OpCnt=

CTRL/Q1XSWI1
CTRL/Q1CSWI1
Disconnector
Q1 OpCnt=
CTRL/Q8XSWI1
CTRL/Q8CSWI1
Ground switch
Q8 OpCnt=

CTRL/Q8XSWI1
CTRL/Q8CSWI1
Ground switch
Q8 OpCnt=
CTRL/Q2XSWI1
CTRL/Q2CSWI1
Disconnector
Q2 OpCnt=

CTRL/Q2XSWI1
CTRL/Q2CSWI1
Disconnector
Q2 OpCnt=
CTRL/Q9XSWI1
CTRL/Q9CSWI1
Disconnector
Q9 OpCnt=

Page 9 of 10

SIMATIC
No.

DEWA / REVISED V1.2 / BRSH SS_F_DREP_M1FP_7SD5/7SD522


Group

Information

Type

Source Destination Extended

02.04.11 19:00:38
Assigned IEC 61850 object (LD /
LN / DO)

00635 Measurement

U2 (negative sequence)

MV

MEAS/MSQI1/SeqV

00641 Measurement

P (active power)

MV

MEAS/MMXU1/TotW

00642 Measurement

Q (reactive power)

MV

MEAS/MMXU1/TotVAr

00643 Measurement

Power Factor

MV

MEAS/MMXU1/TotPF

00645 Measurement

S (apparent power)

MV

MEAS/MMXU1/TotVA

07761 Measure relay1

Relay ID of 1. relay

MV

MEAS/MMXU2/RelId

07762 Measure relay1

IL1(% of Operational nominal current)

MV

MEAS/MMXU2/A

07763 Measure relay1

Angle IL1_rem <-> IL1_loc

MV

MEAS/MMXU2/A

07764 Measure relay1

IL2(% of Operational nominal current)

MV

MEAS/MMXU2/A

07765 Measure relay1

Angle IL2_rem <-> IL2_loc

MV

MEAS/MMXU2/A

07766 Measure relay1

IL3(% of Operational nominal current)

MV

MEAS/MMXU2/A

07767 Measure relay1

Angle IL3_rem <-> IL3_loc

MV

MEAS/MMXU2/A
MEAS/MMXU3/A

07769 Measure relay1

UL1(% of Operational nominal voltage)

MV

MEAS/MMXU2/PhV

07770 Measure relay1

Angle UL1_rem <-> UL1_loc

MV

MEAS/MMXU2/PhV

07771 Measure relay1

UL2(% of Operational nominal voltage)

MV

MEAS/MMXU2/PhV

07772 Measure relay1

Angle UL2_rem <-> UL2_loc

MV

MEAS/MMXU2/PhV

07773 Measure relay1

UL3(% of Operational nominal voltage)

MV

MEAS/MMXU2/PhV

07774 Measure relay1

Angle UL3_rem <-> UL3_loc

MV

MEAS/MMXU2/PhV

07781 Measure relay2

Relay ID of 2. relay

MV

MEAS/MMXU3/RelId

07782 Measure relay2

IL1(% of Operational nominal current)

MV

MEAS/MMXU3/A

07783 Measure relay2

Angle IL1_rem <-> IL1_loc

MV

MEAS/MMXU3/A

07784 Measure relay2

IL2(% of Operational nominal current)

MV

MEAS/MMXU3/A

07785 Measure relay2

Angle IL2_rem <-> IL2_loc

MV

MEAS/MMXU3/A

07786 Measure relay2

IL3(% of Operational nominal current)

MV

MEAS/MMXU3/A

07787 Measure relay2

Angle IL3_rem <-> IL3_loc

MV

MEAS/MMXU3/A

07789 Measure relay2

UL1(% of Operational nominal voltage)

MV

MEAS/MMXU3/PhV

07790 Measure relay2

Angle UL1_rem <-> UL1_loc

MV

MEAS/MMXU3/PhV

07791 Measure relay2

UL2(% of Operational nominal voltage)

MV

MEAS/MMXU3/PhV

07792 Measure relay2

Angle UL2_rem <-> UL2_loc

MV

MEAS/MMXU3/PhV

07793 Measure relay2

UL3(% of Operational nominal voltage)

MV

MEAS/MMXU3/PhV

07794 Measure relay2

Angle UL3_rem <-> UL3_loc

MV

MEAS/MMXU3/PhV

00924 Energy

Wp Forward

MVMV

MEAS/MMTR1/SupWh

00925 Energy

Wq Forward

MVMV

MEAS/MMTR1/SupVArh

00928 Energy

Wp Reverse

MVMV

MEAS/MMTR1/DmdWh

00929 Energy

Wq Reverse

MVMV

MEAS/MMTR1/DmdVArh

01000 Statistics

Number of breaker TRIP commands

VI

PROT/XCBR1/OpCnt

01027 Statistics

Accumulation of interrupted current L1

VI

PROT/XCBR1/SumSwARs1
PROT/XCBR2/SumSwARs

01028 Statistics

Accumulation of interrupted current L2

VI

PROT/XCBR1/SumSwARs2
PROT/XCBR3/SumSwARs

01029 Statistics

Accumulation of interrupted current L3

VI

PROT/XCBR1/SumSwARs3
PROT/XCBR4/SumSwARs