Facultad Politcnica
L= 0,9 mH/km
C=0,015 F/km
Encontrar:
a) La tensin y corriente en el extremo generador
Lnea de longitud media
VS = A.VR +B.IR
IS = D.IR + C.VR
Z = (R + jL).l = (0,035 + j.2.60.0,9.10-3).200 = 68, 2284,11
Y = (G+jC).l = (0 + j.2.60.0,015.10-6).200 = 1,131.10-3 90 S
A=D= 1+
Z .Y
(68, 2284,11).1,131.103 90S
= 1+
= 0,9616 0,236
2
2
Z .Y
(68, 2284,11)(1,131.103 90S )
) = (1,131.103 90S )(1
=
4
4
C=1,11.10-3 90,12 S
IR
PR
400.106W
759, 67 A
3.U R .FP
3.380.103V .0,8
VR
380.103
V
3
380.103V
) + ( 68, 2284,11 )(759,67 -36,87)
3
VS=249209,62 8,985V
US= 3 VS=431643,72 8,985 V
IS = D.IR + C.VR=(0,9616 0,236)( 759,67 -36,87) + (1,11.10-3 90,12 S) (
IS=616,47 -18,2 A
b) La regulacin de tensin
431643, 72V
US
380.103V
UR
0,9616
.100 %=
Reg T= A
.100%
UR
380.103V
Reg T =18,13%
c) La eficiencia
PR 400MW
PS 3.U S .I S .cos( ) 3.(431643, 72V ).(616, 47 A).cos(8,985 (18, 2))
PS 409978927, 6W
PR
400.106W
.100%
.100%
PS
409978927, 6W
97,57%
380.103V
)
3
VS = A.VR +B.IR
IS = D.IR + C.VR
Z = (R + jL).l = (0,036 + j.2.60.0,8.10-3).130=39,49 83,2
Y = (G+jC).l = (0 + j.2.60.0,0112.10-6).130 = 5,49.10-4 90 S
A D 1
Z .Y
(39, 4983, 2)(5, 49.104 90S )
1
0,9890, 07434
2
2
B=Z=39,49 83,2
Z .Y
(39, 4983, 2)(5, 49.104 90S )
) (5, 49.104 90S )(1
) 5, 46.104 90, 04 S
4
4
SR
270.106VA
IR
479, 64 A
3.U R
3.325.103V
C Y (1
I R I R cos 1 (0,8)
I R 479, 64 36,87 A
VS AV
. R B.I R (0,9890, 07434)(
325.103V
) (39, 4983, 2)(479, 64 36,87)
3
VS=199142,07 4,0144 V
US=
.VS=
.(199142,07 4,0144 V)
US=344924,2 4,0144 V
325.103V
)
3
PS=218661044,6 W
US
UR
A
Reg T=
.100 % =
UR
100 % = 7,31 %
A=D=1
IS = D.IR + C.VR
B=Z
C=0
999,87 A
3.U R
3.220.103V
I R I R cos1 (0,8) 999,87 36,87 A
220.103V
VS AV
. R B.I R 1.(
) (20,8873,3)(999,87 36,87) 144348,3434,93V
3
US=
.VS=
.(144348,343 4,93 V)
US=250018,7 4,93 V
IS = D.IR + C.VR= 1.(999,87 -36,87A) + 0 = 999,87 -36,87 A
PS 3.U S .I S .cos( ) 3.(250018,7V )(999,87 A).cos(4,93 (36,87))
PS=322782755,1 W
US
UR
A
.100 % =
Reg T=
UR
Reg T =13,65 %
100 %
PR
304,8.106W
.100%
.100% 94, 43%
PS
322782755,1W
94, 43%
b- 381 MVA a factor de potencia 0,8 en adelanto
VS = A.VR +B.IR
A=D=1
IS = D.IR + C.VR
B=Z
C=0
SR
381.106VA
999,87 A
3.U R
3.220.103V
VS AV
. R B.I R 1.(
US=
.VS=
220.103V
) (20,8873,3)(999,8736,87) 121410, 069,3V
3
.(121410,06 9,3 V)
US=210288,4 9,3 V
IS = D.IR + C.VR= 1.(999,87 36,87A) + 0 = 999,87 36,87 A
PS 3.U S .I S .cos( ) 3.(210288, 4V )(999,87 A).cos(9,3 36,87)
PS=322828438,7 W
US
UR
.100 % =
Reg T= A
UR
Reg T = -4,4 %
100 %
PR
304,8.106W
.100%
.100% 94, 42%
PS
322828438, 7W
94, 42%
Comentario: Comparando los casos a y b demostraron la misma eficiencia en la
transmisin en cambio en la regulacin de tensin hubo diferencia.
4- Una lnea de transmisin de 500 kV trifsica tiene una longitud de 250 km. La
impedancia serie es de Z=0,045 + j0,4 por fase por km y admitancia shunt Y=j4.10-6
siemens por fase por km. Evaluar el equivalente y la matriz de transmisin.
ZC
Z
(0, 045 j 0, 4)
l
2
l
2
l
2
8,85.103 j 0,15835
l
2
8,85.103
9, 0728
senh(
Y
1
l
1
2
.tgh( )
.
2 ZC
2
ZC cosh( l )
2
e e 2
l
l
e 2 e 2
1
1
2
2
. l 2
l
l
ZC 2l
Z
l
C
e e 2
e 2 e 2
2
2
2
2
Y
1
e8,85.10 9, 0728 e8,85.10 9, 0728
. 8,85.103
4,9974.104 90, 038S
8,85.103
2 317, 2236 3, 21 e
9, 0728 e
9, 0728
A D 1
Z .Y
Y
1 Z . 1 (98,953383, 7)(4,9974.104 90, 038S ) 0,950860,325
2
2
B Z 98,953383,7
C Y (1
Z Y
Y
Z Y
98,953383, 7
) 2. (1 ) 2(4,9974.104 90, 038S )(1
.4,9974.104 90, 038S )
2 2
2
2 2
2
C 9,7492.104 90, 2S
VS = A.VR +B.IR
IS = D.IR + C.VR
Matriz de transmisin
0,950860,325
VS
I S 9, 7492.104 90, 2
98,953383, 7
VR
I
0,950860,325 R
Circuito equivalente
Z 98,953383,7
Y
4,9974.104 90,038S
2
5- Una lnea de transmisin de 500kV de 60Hz trifsica tiene una longitud de 300 km.
La inductancia de la lnea es de 0,97 mH/km por fase y la capacitancia de 0,0115
F/km por fase. Asumir que no existen perdidas en la lnea.
a-Determinar la constante de propagacin, la impedancia caracterstica ZC, la
velocidad de propagacin v y la longitud de onda de la lnea .
Z R j L 0 j L j L
Y G jC 0 jC jC
Z .Y
j L
L
0,97.103
290, 427
jC
C
0, 0115.106
ZC 290, 427
v
1
1
299409, 2495km / s
LC
(0,97.103 )(0, 0115.106 )
v 299409, 2495km / s
v 299409, 2495km / s
4990,154km
f
60 Hz
2
2
4990,154km
1, 2591165.103 km1
4990,154km
U R 500 KV
500 KV
3
PR 800MW
VR
FP 0,8(atraso)
PR 3.U R .I R .FP
PR
800.106 W
IR
1154, 7 A
3.U R .FP
3.500.103V .0,8
I R I R cos 1 (0,8) 1154, 7 36,87 A
2
2
2
A D 0,9295
e l e l e0 l e0 l 121, 6426 1 21, 6426
j 0,3688
2
2
2
B ZC .senh( l ) (290, 427).( j 0,3688) j107,114 107,11490
senh( l )
1
1
.senh( l )
.( j 0,3688) 1, 26985.10 3 90S
ZC
290, 427
VS AV
. R B.I R (0,9295).(
500.103V
) (107,11490)(1154, 7 36,87 A) 356539,5416,1124V
3
U S 3.VS 3.(356539,5416,1124V )
U S 617544,616,1124V
500.103V
)
3
I S 902,333 17,9V
PS 3.U S .I S .cos( ) 3.(617544,6V )(902,333 A).cos(16,1124 (17,9))
PS 800030598,9W
| US |
617544, 6V
|UR |
500.103V
| A|
0,9295
Re g
100%
100%
|UR |
500.103V
Reg T = 32,88%
PR
800.106W
.100%
.100% 99,9962%
PS
800030598,9W
99,9962%
6- Una lnea de transmisin de 550kV de 60Hz trifsica tiene una longitud de 300 km.
Los parmetros de la fase por unidad de longitud son:
r=0,036 /km
L= 0,97 mH/km
C=0,0115 F/km
a- Determinar el desempeo de la lnea cuando la carga alimentada en el
extremo receptor es 800 MW, factor de potencia 0,8 en atraso a 500kV.
Lnea de longitud larga
Z
0,3674584,38
2
2
2
A D 0,92951020, 42112
A D cosh( l )
0,369787,335
2
2
2
B Z C .senh( l ) (291,13 2,81).(0,369787,335) 107, 6384,525
senh( l )
1
1
.senh( l )
.(0,369787,335) 1, 27.10 3 90,145S
ZC
291,13 2,81
U R 500 KV
500 KV
3
PR 800MW
VR
FP 0,8(atraso)
PR 3.U R .I R .FP
IR
PR
800.106 W
1154, 7 A
3.U R .FP
3.500.103V .0,8
500.103V
) (107, 6384,525)(1154, 7 36,87 A) 364323, 214,92V
3
U S 631026,314,92V
500.103V
I S D.I R C.VR (0,92951020, 42112)(1154, 7 36,87 A) (1, 27.10 90,145S )(
)
3
I S 904,014 17, 45 A
3
PS 834523601,6W
| US |
631026,3V
|UR |
500.103V
| A|
0,9295102
Re g
100%
100%
|UR |
500.103V
Reg T = 35,78%
PR
800.106W
.100%
.100% 95,863%
PS
834523601, 6W
95,863%
VS
S V .I *
(600 j 400).106
S
3
IS *
793, 02 33, 7 A
525.103V
VS
3
*
VR AV
. S B.I S (0,92951020, 42112).(
525.103V
) (107,6384,525)(793,02 33,7 A) 236663,63 15,71V
3
U R 409913, 44 15,71V
PR 573602659,1W
| US |
525.103V
|UR |
409913, 44V
| A|
0,9295102
Re g
100%
100%
|UR |
409913, 44V
Reg T = 37,79%
PR
573602659,1W
.100%
.100% 95, 6%
PS
600.106W
95,6%
525.103V
)
3
Z R 290
U R 500 KV
500.103V
3
500.103V
V
3
IR R
995, 4315 A
ZR
290
VR
VS AV
. R B.I R (0,92951020, 42112).(
500.103V
) (107, 6384,525)(995, 4315 A) 298971, 621,3V
3
U S 517833,9821,3V
500.103V
I S D.I R C.VR (0,92951020, 42112)(995, 4315 A) (1, 27.10 90,145S )(
)
3
3
I S 996,8922 A
PS 3.U S .I S .cos( ) 3.(517833,98V )(996,89 A).cos(21,3 22)
PS 894058629,5W
| US |
517833,98V
|UR |
500.103V
| A|
0,9295102
Re g
100%
100%
|UR |
500.103V
Reg T = 11,42%
PR 3.U R .I R .FP 3.(500.103V ).(995, 4315 A).1 862068966,7W
PR
862068966, 7W
.100%
.100% 96, 422%
PS
894058629,5W
96, 422%
d- Determinar el perfil de tensin de la lnea para los siguientes casos: sin carga,
carga nominal, lnea terminada en el SIL y lnea cortocircuitada.
1, 26214.103 87, 2km1
I ( x) I (0).cosh( x)
I R I S .cosh( l )
1
V (0).senh( x)
ZC
VS
V
senh( l ) 0 I S S tgh( l )
ZC
ZC
Carga nominal:
Se considera VR Z L .I R
1
VS .sen( l )....(2)
ZC
VS .cos( l )
IS
Z'
Y'
j 0,3657.103 / m
290, 4343 Z L
j 4,3354.109 S / m
VS
.cos( l ) jI S .sen( l )
ZC '
I R I S .cos( l ) j
VS
sen( l )
ZC '
Comparando las dos ecuaciones para I R se puede verificar que VS ZC '.I S y la ecuacin
de tensin queda:
V ( x) VS .cos( x) jVS .sen( x) VS [cos( x) jsen( x)]
V ( x) VS .e j x
Lnea cortocircuitada
En cortocircuito se tiene que Z L 0 y consecuentemente VR 0 . De la ecuacin de la onda
de tensin se tiene:
V ( x) V (0).cosh( x) Z C .I (0).senh( x)
VR VS .cosh( l ) ZC .I S .senh( l ) 0 I S
VS
....(4)
ZC .tgh( l )
V ( x) VS .(cosh( x)
senh( x)
)
tgh( l )
550.103V
obtenemos el siguiente grfico que representa las
3
diversas tensiones a lo largo de la lnea de 300km correspondiente a cada caso
Considerando una tensin VS
3.5
x 10
Tension en [V]
2.5
Vaco
Carga nominal
SIL
Cortocircuito
1.5
0.5
0
0
0.5
1
1.5
2
Longitud de la lnea en [metros]
2.5
3
5
x 10
7- Una lnea de transmisin trifsica de 60Hz tiene una longitud de 175 millas. La
lnea tiene una impedancia serie total de 35 + j140 y una admitancia en paralelo de
j0,00093 siemens. Entrega 40 MW a 220 kV con 90% de factor de potencia en atraso.
Encuentre la tensin en el extremo generador mediante:
Z (35 j140)
Y j 0, 00093S
PR 40 MW
U R 220 KV
220.103V
3
FP 0,9(atraso)
VR
PR 3.U R .I R .FP
PR
40.106 W
IR
116, 64 A
3.U R .FP
3.220.103V .0,9
I R I R cos 1 (0,9) 116, 64 25,842 A
A=D=1
VS AV
. R B.I R (1).(
B=Z
C=0
220.103V
) ((35 j140))(116, 64 25,842 A) 138413, 25,355V
3
U S 239738,6855,355V
220.103V
) ((35 j140))(116, 64 25,842 A) 130398,836,5985V
3
U S 3.VS 3.(130398,836,5985V )
U S 225857, 46,5985V
l 0, 044755
l 0,3635556rad
l 20,83
e l e l e l l e l l e0,04475520,83 e 0,044755 20,83
A D cosh( l )
2
2
2
A D 0,93570,975
e l e l e l l e l l e0,04475520,83 e0,044755 20,83
senh( l )
0,358483,3
2
2
2
B Z C .senh( l ) (393,92 7, 02).(0,358483,3) 141, 276,3
VS AV
. R B.I R (0,93570,975).(
U S 3.VS 3.(130153,326,5V )
U S 225432,166,5V
220.103V
) (141, 276,3)(116, 64 25,842 A) 130153,326,5V
3
8- Una lnea de transmisin trifsica de 60Hz tiene una longitud de 175 millas. La
lnea tiene una impedancia serie total de 35 + j140 y una admitancia en paralelo de
j0,00093 siemens. Entrega 40 MW a 220 kV con 90% de factor de potencia en atraso.
Determinar el circuito equivalente .
Z (35 j140)
Y j 0, 00093S
PR 40 MW
U R 220 KV
220.103V
VR
3
FP 0,9(atraso)
PR 3.U R .I R .FP
IR
PR
40.106 W
116, 64 A
3.U R .FP
3.220.103V .0,9
ZC
Z
(35 j140)
j
0, 0223775 j 0,1817778
2
2
2
l
0, 0223775
2
l
0,1817778rad
2
l
10, 4151
2
2
2
2
A D 0,93570,975
e l e l e l l e l l e0,04475520,83 e0,044755 20,83
senh( l )
0,358483,3
2
2
2
Z B Z C .senh( l ) (393, 92 7, 02).(0,358483,3) 141, 276,3
senh(
Y
1
l
1
2
.tgh( )
.
2 ZC
2
ZC cosh( l )
2
e2 e 2
l
l
e 2 e 2
1
1
2
. l 2 l
. l 2
l
ZC 2
Z
l
C
e e 2
e 2 e 2
2
2
2
Y
1
e0,022377510, 4151 e0,0223775 10, 4151
. 0,0223775
4, 7005.104 89,844225S
2 393,92 7, 02 e
10, 4151 e0,0223775 10, 4151
Circuito equivalente
Z 141, 276,3
Y
4,7005.104 89,844225S
2
f 60 Hz
PR 20 MW
U R 69 KV
69.103V
VR
3
FP 0,8(atraso)
l 50km
PR 3.U R .I R .FP
IR
PR
20.106 W
209,185 A
3.U R .FP
3.69.103V .0,8
A=D=1
VS AV
. R B.I R (1).(
B=Z
C=0
69.103V
) (21, 63475, 272)(209,185 36,87 A) 43474, 73, 71V
3
U S 75300,3253,71V
PS 20721199,62W
b- La regulacin de tensin
| US |
75300,325V
|UR |
69.103V
| A|
1
Re g
100%
100%
|UR |
69.103V
Reg T = 9,1309%
c- La eficiencia
PR
20.106W
.100%
.100% 96,52%
PS
20721199, 62W
96,52%