Transformer protection relays

series

20

model

P721

P630C

P631

20TE

Compact

40TE

Case size
CT Inputs
VT Inputs
Opto Inputs (max)
Output Contacts (max)
Analogue Input/Output (max )
RTDs (option)
Function Keys/Hotkeys
Interlocking logic
PROTECTION FUNCTION

Overexcitation
Negative sequence
overcurrent
Negative sequence
overvoltage
Thermal overload
Ground fault
Phase overcurrent
Circuit breaker failure
Over/Under voltage
Ground fault directional
Phase directional
Under/Over frequency
Restricted earth fault
Transformer diff. (windings)
CT supervision
Trip Circuit Supervision
VT supervision
2 nd harmonic restraint
Overfluxing/ 5th harmonic

Busbar protection relays


30

14

P632

40
P633

40 or 84TE 40 or 84TE

P634

P642

P643

P645

84TE

40TE

60TE

60 or 80TE

50/51N

50/51P
50BF

24

10

10

10

PROTECTION FUNCTION

ANSI

Ground fault
Phase overcurrent
Circuit breaker failure
Busbar
Check Zones
Phase segregated differential
Sensitive earth fault differential
CT supervision
Trip Circuit Supervision
VT supervision
Phase comparison
Central unit (Nbr of feeders)
Peripheral units 8 zones
CT supervision
CT saturation detection

50/51N

50/51P

24

24

TCS

VTS

3
5

16

24

40

21

32

50BF

87BB

87CZ

87P

8 zones

2 zones

87P

8 zones

CTS

TCS

VTS

No limit

up to 28

Voltage, frequency, and ancillary protection relays


series
20
model
Dimensions
CT Inputs
VT Inputs
Opto Inputs (max)
Output Contacts (max)
PROTECTION FUNCTION

Check synchronising
Undervoltage
Phase sequence voltage
Breaker failure protection
Overvoltage
Residual overvoltage
Restricted earth fault
Wattmetric earth fault
Phase directional with DLR option

22

18

4/4

12

67P

87T

24

34

CTS

4/4

40

80TE

12

34

67N

87G/64

P746

60TE

4/4

1 or 4

81

P743

40TE

22

18

1 or 4

P742

80TE

1/2

12

1 or 2

P741

20TE

30

59/27

P723

1/2

15

Device

22

12

47
49

40

1/2

46

20

Case size
CT Inputs
VT Inputs
Opto Inputs (max)
Output Contacts (max)
Function Keys/Hotkeys

ANSI
24

series

P821

P921

P922

P923

P341

P841

P849

20TE

20TE

20TE

20TE

40 TE or 60TE

60TE or 80 TE

80TE

5 or 8

4
4

4 or 5

16

16 or 24

64

15

14 or 32

60

1 or 2

1 or 2

ANSI
25
27
47/27D
50BF

59

59N

64

64N/32N

67P

Autoreclose

79

Under/Over frequency

81

Rate of change of frequency (df/dt+t)


Frequency supervised average
rate of change of frequency (f+f/t)
Frequency supervised rate of
change of frequency (f+df/dt)
Voltage vector shift
Trip circuit supervision
3 pole tripping
Ferroresonance detection
High speed contact

40

1 or 1/2

81R

81RAV

81RF

dVq

TCS

23