Sunteți pe pagina 1din 8

MAHIMTURA CONSULTANTS PVT.

LTD

Project :- Residential Tower at Curry Road, Mumbai


For NISH DEVELOPERS PVT LTD

C/ 6589 /2014

Date: 10/04/14
DESIGN BASIS REPORT

PROJECT

PROPOSED RESIDENTIAL TOWER AT CURRY ROAD MUMBAI

CLEINT

M/S. NISH DEVELOPERS PVT. LTD.

ARCHITECT

VIVEK BHOLE

STRUCTURAL CONSULTANT

M/S. MAHIMTURA CONSULTANTS PVT. LTD.

GEO-TECH CONSULTANTS

PROF. G. B . CHAUDHARI

1.

INTRODUCTION
The RESIDENTIAL Building consists of Lower basement + Ground floor + 9 podium Floor
+ Service Floor + 56 typical floors + Terrace & LMR / OHT

2.

AIM OF DESIGN
The aim of design is the achievement of an acceptable probability that structures being
designed will perform satisfactorily during their intended life. With an appropriate degree of
safety, they should sustain all the loads and deformations of normal construction and use and
have adequate durability and adequate resistance to the effects of misuse and fire.

3.

DESIGN ASSUMPTION
a)

Structural System
The Structural system for the Residential Building consists of RCC framed (column,
beams, slabs & shear wall) structure.

3.

DESIGN LOADS
a)

Imposed Loads
The Imposed Loads that are envisaged to act permanently (wherever applicable) are
as following :-

Item
Floor finish 20thk tiles on 20thk cement mortar
Weathering Proof course 100thk brickbat coba

Intensity in KN/m2 of plan area


1.5
2

with IPS finish.

Page No. 1

MAHIMTURA CONSULTANTS PVT. LTD

Project :- Residential Tower at Curry Road, Mumbai


For NISH DEVELOPERS PVT LTD

The superimposed load or otherwise live load is assessed based on the occupancy
classifications as per IS:875 (Part 2) 1987 and are listed as below.
Residential building
Residential building
Residential building
Residential building
Residential building
Multipurpose Hall
Podium (Parking floors)
Refuse floor
4.

Occupancy Classification
Residential Room
Toilets & Bath Rooms
Staircase & Corridors
Roof with access
Car parking (Double stack parking)
-

UDL (KN/m2)
2
2
3
1.5
4
5
4

WIND LOADS ;
Wind tunnel report is enclosed ;

5.

Base dimension along X-dir, L

112.65 m

Base dimension along Y-dir, B

54.7 m

Time period x direction as per 0.1 n

6.8 sec

Time period y direction as per 0.1 n

6.8 sec

Time period x direction as per E tabs model

6.45 sec

Time period y direction as per E tabs model

5.99 sec

Aspect Ratio = H/L = 255.35/ 112.65

2.27 . Along X- dir

Aspect Ratio = H/B = 255.35/ 54.7

4.67 . Along Y- dir

EARTHQUAKE LOAD
The loading due to earthquake is assessed based on the provisions of IS:1893(Part-1):2002

Seismic Zone

III

Table-2

Zone factor (Z)

0.16.

Table-6

Importance Factor (I)

1.00 (Residential Building)

Table-7

Response Reduction Factor (R)

4.0

Height of building (H)

255.35 m

Base dimension of the building along the


considered direction of lateral force (D )

Soil type

L = 112.65 m
B = 54.7 m
Hard soil

Page No. 2

MAHIMTURA CONSULTANTS PVT. LTD

Project :- Residential Tower at Curry Road, Mumbai


For NISH DEVELOPERS PVT LTD

Fundamental natural time period (Ts) with INFILL WALLS in x direction


Ts

Sa/g

0.09 x h / d 0.5

0.09 x 255.35 / 112.65 0.5

2.15

0.46

..from CL.7.6.2 IS1893 (part I):2002

from FIG-2 IS 1893 (part I):2002

Fundamental natural time period (Ts) with INFILL WALLS in y direction


Ts

Sa/g

0.09 x h / d 0.5

0.09 x 255.35 / 54.7 0.5

3.02

0.33

..from CL.7.6.2 IS1893 (part I):2002

from FIG-2 IS 1893 (part I):2002

HORIZONTAL SEISMIC CO-EFFICIENT IN X DIRECTION


Ah

Z x I x Sa
2 xRxg
0.16 x 1 x 0.46
2x4

= 0.0093

DESIGN BASE SHEAR IN X DIRECTION


Vb

Ah x W

0.0093 X 3978616.56

37010.39 K N

HORIZONTAL SEISMIC CO-EFFICIENT IN Y DIRECTION


Ah

Z x I x Sa
2 xRxg
0.16 x 1 x 0.33
2x4

= 0.0066

DESIGN BASE SHEAR IN Y DIRECTION


Vb

Ah x W

0.0066 X 3978616.56

26258.87 K N

Page No. 3

MAHIMTURA CONSULTANTS PVT. LTD

Project :- Residential Tower at Curry Road, Mumbai


For NISH DEVELOPERS PVT LTD

STOREY DRIFT
The storey drift in any storey due to the minimum specified design lateral force, with partial
load factor of 1.0, shall not exceed 0.004 times the storey height.
SOFTWARE USED:ETABS
SAFE
6.

CHECK FOR LATERAL SWAY AS PER IS 456-2000


The allowable lateral sway under wind loading at top limited to H/500, where H is total
height of building.

7.

BASIC LOADS AND LOAD COMBINATIONS


The various loads are combined in accordance with the stipulations in IS:875 (Part 5)-1987.
Wherever imposed load is combined with earthquake load the appropriate part of the
imposed load as specified in IS:1893-2002 is adopted both for evaluating earthquake effect
and for combined load effects, used in such combination.
DL+LL
DL+EQX
DL-EQX
DL+EQZ
DL-EQZ
DL+WLX
DL-WLX
DL+WLZ
DL-WLZ
*****FACTORED LOAD CASES
1.5[DL+LL]
1.5[DL+EQX]
1.5[DL-EQX]
1.5[DL+EQZ]
1.5[DL-EQZ]
1.2[DL+LL+EQX]
1.2[DL+LL-EQX]
1.2[DL+LL+EQZ]
1.2[DL+LL-EQZ]

Page No. 4

MAHIMTURA CONSULTANTS PVT. LTD

Project :- Residential Tower at Curry Road, Mumbai


For NISH DEVELOPERS PVT LTD

****STRESS REVERSAL
[0.9DL+1.5EQX]
[0.9DL-1.5EQX]
[0.9DL+1.5EQZ]
[0.9DL-1.5EQZ]
**********WIND
1.5[DL+WLX]
1.5[DL-WLX]
1.5[DL+WLZ]
1.5[DL-WLZ]
1.2[DL+LL+WLX]
1.2[DL+LL-WLX]
1.2[DL+LL+WLZ]
1.2[DL+LL-WLZ]
***********STRESS REVERSAL
[0.9DL+1.5WLX]
[0.9DL-1.5WLX]
[0.9DL+1.5WLZ]
[0.9DL-1.5WLZ]
8.

LOAD FACTORS FOR DESIGN


Description of Load Combination

Load Factor for Primary Load Cases


Live
Wind
Seismic
Lo Load
Load
Load
ad
1.5
1.5
0.0
0.0
1.5
0
1.5
0.0
1.5
0
0
1.5
1.2
1.2
1.2
0.0
1.2
1.2
0
1.2
0.9
0
1.5
0.0
0.9
0
0
1.5

Dead
Dead load + Live load
Dead load + Wind load
Dead load + Seismic load
Dead load + Live load + Wind load
Dead load + Live load + Seismic load
Dead load + Wind load
Dead load + Seismic load
9.

ANALYSIS METHOD
The structure is analysed for Gravity Load and Lateral loads due to Earthquake/Wind loads
and its combinations.

10.

DESIGN METHODOLOGY

Page No. 5

MAHIMTURA CONSULTANTS PVT. LTD

Project :- Residential Tower at Curry Road, Mumbai


For NISH DEVELOPERS PVT LTD

All structural RCC members have been designed according to the Limit State Method as
specified in IS: 456-2000. All structural steel members have been designed according to
specified in IS: 800-2007. Appropriate loads and its combinations, as per relevant clauses in
Code IS: 456-2000, Code IS: 875 (Part-5) 1987, for the most unfavorable effects are chosen
for design.
11.

MATERIALS
The self-weight of the various elements are computed based on the built weight of materials
as given below:-

12

Materials

Unit Weight in KN/m3

Steel
Plain Concrete
Reinforced Concrete
Soil
Water
Brick, Fly ash block

78.50
24.00
25.00
18.00
10.00
20.00

CONSTRUCTION DETAILS
1.

Raft Foundation

Concrete Mix

M:40

Steel Fe500

2.

Columns

Concrete Mix
Steel

M: 60 ,M;50 , M40 , M30


Fe500

3.

Beams & Slabs

M50 , M40 , M30 & Steel Fe 500

4.

External Wall

150 thk LIGHT WT Block wall as per architect layout.

5.
6.

Internal Wall
Floor to Floor HT

125 thk LIGHT WT block wall as per architect layout.


3.85 m

13.

CONCRETE

14.

All the concrete items for the construction have the following characteristics
Grade of Concrete
=
M60/M50/M40/M30
(Concrete design Mix as per IS 456-2000)
M15 (For P.C.C. )
Aggregate
=
20mm and down size, mechanically crushed
Aggregate
REINFORCEMENT
Steel reinforcement shall be of Grade Fe500 conforming to IS:1786-1985.

15

STRUCTURAL STEEL
Structural steel used in project is of Grade Fe250 and Fe350.

16.

EXPOSURE CONDITION

Page No. 6

MAHIMTURA CONSULTANTS PVT. LTD

Project :- Residential Tower at Curry Road, Mumbai


For NISH DEVELOPERS PVT LTD

Structural elements below Plinth level and Exterior External faces of walls are designed for
Moderate exposure condition and internal faces of walls, floor beams and slabs are designed
for mild exposure condition as per Table 16 of IS 456-2000.
17

COVER TO REINFORCEMENT
The clear cover to main reinforcement shall be as per IS: 456-2000.

18.

FOUNDATION SYSTEM
The structure is supported on columns and shear wall with RAFT foundation.
S.B.C. considered as per soil investigation report provided by PROF. G. B. CHAUDHARI

19.

CODES & STANDARDS


All the designs are conforming to the relevant Indian Standards. Some of the relevant Indian
Standard Codes, which have been followed for the structural designs, are given below.
Code

Description

IS:875 (Part-1)-1987

Code of Practice for Design Loads (Other than Earthquake) for


Building and Structures-Unit Weights of Buildings Materials
and Stored Material.

IS:875 (Part-2)-1987

Code of Practice for Design Loads (Other than Earthquake) for


Building and Structures-Imposed loads

IS:875 (Part-3)-1987

Code of Practice for Design Loads (Other than Earthquake) for


Buildings and Structures Wind Load.

IS:875 (Part-5)-1987

Code of Practice for Design Loads (Other than Earthquake) for


Buildings and Structures - Special Loads and Load
Combinations
Code of Practice for Plain and Reinforced Concrete

IS:456 -2000
IS:1893 (Part-1)-2002

Indian Standard Criteria for Earthquake Resistant Design of


Structures

IS:432 (Part-1)-1982

Specification of Mild Steel and Medium Tensile Steel bars and


Hard drawn Steel Wire for concrete reinforcement Mild Steel
and Medium Tensile Steel Bars.
Specification of Mild Steel and Medium Tensile Steel bars and
Hard drawn Steel Wire for concrete reinforcement Hard
drawn Steel Wire.
Specification for High Strength Deformed Steel Bars and
Wires for Concrete Reinforcement
Ductile Detailing of reinforced concrete structures subjected to
seismic forces code of practice.
Indian Standard Code of practice for Design & Construction
foundations in Soil: General Requirements.
Indian Standard Code of practice for Fire Safety Of Buildings
(General) : Details Of Construction.

IS:432 (Part-2)-1982
IS:1786-1985
IS:13920-1993
IS:1904
IS:1642-1989

TYPICAL CALCULATION FOR ARRIVING AT DUCTILE DETAILING:

Page No. 7

MAHIMTURA CONSULTANTS PVT. LTD

Project :- Residential Tower at Curry Road, Mumbai


For NISH DEVELOPERS PVT LTD

Size

1400 x 1200

As per IS:13920 : 1993 Clause 7.4.8


The area of cross section, Ash, of the bar forming rectangular hoop to be used as special confining
reinforcement shall not be less than.
Ash

0.18 x s x h x fck
fy

Ag - 1.0
Ak

For Concrete Mix M:50


fck =

50 N/mm2

Ash =

0.18 x 75 x 300 x

Ash

405

1.10

40.50mm2

Clear cover = 40 mm
50 1400 x 1200- - 1.0
500
1336 x 1136

- 1.0

Provide 8 @ 75mm C/C as hoops / links

H. R. MAHIMTURA
Consulting Structural Engineer
Registration No. STR/M/63

M/s. Mahimtura Consultants Pvt Ltd


Consulting Engineers,
Unique House, 3rd Floor,
25, S. A. Brelvi Road,
Fort, Mumbai 400 001.

Page No. 8