Switching Network (SN(B))

Objectives
The participant is able to
 name the units of the SN(B) and their functions
 localize the modules of the SN(B)
 maintain the SN
 operate the SN

Contents
1
1.1
1.2
1.3
2
2.1
2.2
2.3
3
4

Functional Description
Introduction
Hardware
SN(B) Rack and Module Frames
MML Commands
Interrogating the SN
Configuring SN Components
Diagnose SN Components
Exercises
Solutions

MN2512E6A02

3
4
6
16
19
20
22
26
29
35

Siemens

Switching Network (SN(B))

MN2512E6A02

Switching Network (SN(B))

Siemens

1 Functional Description

MN2512E6A02

Siemens

Switching Network (SN(B))

1.1 Introduction
The switching network SN is the link inside a node for:


traffic connections between LTGs (temporary through connections)

the EWSD internal message exchange between LTG, CCNC and CP control units
via fixed message channels MCH

CCS7 signaling messages between CCS7 signaling channels in PCM links


connected to the LTG and the CCNC (fixed connections set by command).

The switching network is fully duplicated (SN0 and SN1). For traffic connections, one
is the active, the other one the standby side. All calls are always simultaneously
through connected via both SN sides while the LTG only through connects user
channel information received from the active SN to the PCM links. If the active SN
fails the system switches to the standby SN without any loss.
Through connection in the SN occurs in accordance with the "time space time"
principle (change of time slot change of space slot change of time slot). Each
through connection ensures a transparent bidirectional 64kbit/s path through the SN.
In addition to temporary through connections (transient calls), the following nonswitched connections also apply:


nailed-up connections (NUC) set by MML command

through connection of message channels between LTG control units and the
message buffer (permanently specified by CP software).

Every connection between the SN and other functional units use secondary digital
carrier lines (SDC) with a bit rate of 8192kbps (mostly called 8Mbit system or
highways), carrying 128 standard 64kbps time slots (numbers 0-127).

MN2512E6A02

Switching Network (SN(B))

Siemens

LTG1

SN1

SN0

Traffic, CCS7 signaling, internal messages


LTGn

CCNC
CCS7 signaling, internal messages

Coordination Area

Internal messages

Fig. 1 Position of the switching network in the D900 system

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN2512E6A02

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

Siemens

Switching Network (SN(B))

1.2 Hardware
The SN for EWSD systems is available in different capacity stages. With the
exception of the small switching network for a maximum of 63 LTGs (combined
space-time stages), each SN consists of the subunits time stage group (TSG) and
space stage group (SSG).
Time Stage Group (TSG):
Each TSG connects the SDC to/from the LTG, CCNC, and MB. 64 of this SDCs can
be connected to each TSG. An SN is made of a maximum of 8 duplicated TSG. Each
TSG contains a switch group control (SGC) which is connected to the CP via the
message buffer (MB) with an own SDC line. The SGC receives setting instructions
for temporary or fixed bidirectional 64kbps through connections from the CP. The
SGC implements through connections by setting the individual time stage modules
(TSM) in a TSG. Inside a TSG each TSM can change the position in time and space of
any time slot arbitrarily for a group of 8 connected SDC.
Space Stage Group (SSG):
The SSG through connects a call between TSM inside the same or different TSG. An
SN consists of a maximum of 4 duplicated SSG. Inside the SSG is a switch group
control (SGC) connected to the CP via the message buffer (MB). The SGC receives
setting instructions for temporary or fixed bidirectional 64kbps through connections
from the CP. The SGC implements through connections by setting the individual
space stage modules (SSM) in an SSG. Each SSM can change the space slot of the
time slot for connected SDC arbitrarily.
External and internal connections
The following types of secondary digital carriers (SDC) with 8Mbps form the internal
and external interfaces of the SN:

SDC:LTG between TSG and maximum 63 LTG for circuit connections (time slots
1-127) and for message exchange between the LTG GP control unit and the CP
(message channel to time slot 0). Any TSG port can be used except 0, which is
reserved for the SDC:TSG to the message buffer.

one or two SDC:CCNC to through connect CCS7 messages between the CCNC
and the signaling channels in the PCM links. Can use any TSG port except 0 (MB).

one SDC:TSG between TSG and MB to transfer the message channel for all LTG
in this TSG to the CP. Always connected to port 0 of every TSG.

one SDC:SGC between the SGC control unit in a TSG/SSG and the MB to transfer
the CP setting instructions to TSG/SSG

The individual TSG and SSG are connected to each other via SDC:SSG

MN2512E6A02

Switching Network (SN(B))

Siemens

Internal
Interfaces

64 SDC:LTG ports per TSG

SN 0 or SN 1

SDC:LTG

Time
Stage
Group

LTG1
SDC:LTG
LTGn

SDC:SSG

SDC:CCNC

Space
Stage
Group

SDC:SSG

CCNC

Port 0 on every TSG

CP

SDC:SSG

MB
SDC:TSG

MBU
SDC:SGC
SGC
MBU
SDC:SGC
SGC

Fig. 2 Interfaces and internal structure of the SN

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN2512E6A02

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

Siemens

Switching Network (SN(B))

Capacity stages
As the SN is available in different increments the actual size of the switching
network can be matched to the expected traffic volume in an exchange. The volume
of traffic to be through connected measured in Erlangs is used as the dimensional
size.
TIP
In addition to the increments listed the special implementation of SN for 31 LTG and
for 63 LTG is also available for small EWSD.
Capacity / space requirements for SN increments:


If a CCNC is connected, 1 or 2 SDC:CCNC are added depending on the number of


CCS7 signaling channels; the number of SDC:LTG is reduced accordingly.

Space requirements inside a rack:


Each TSG requires only one frame inside a rack. Each SSG requires only a half of a
frame inside a rack. The remaining space inside the rack can be used for LTG.
In a TSG rack it is possible to install a maximum of 4 LTG module frames.
In an SSG rack it is possible to install a maximum of 4 LTG module frames.
In the SN:63LTG rack it is possible to install a maximum of 4 LTG module frames.
The SN:31LTG is stored inside the CP rack.

TIP
Mobile systems are not fully equipped with all possible LTGs. Because of the much
higher signaling load in a PLMN, the amount of internal messages would be too high
for the message buffer. Fig. 3 shows the capacity stages of EWSD and D900
systems.

MN2512E6A02

Switching Network (SN(B))

Siemens

Capacity stages of the switching networks


EWSD exchanges

SN126

SN252

SN504

Maximum number of SDC:LTGs

126

252

504

Maximum number of SDC:CCNC

Number of SDC:TSG for message exchange

Number of SDC:SGC for call setup

12

SN126

SN252

SN504

Maximum number of SDC:LTGs

62

124

248

Maximum number of SDC:CCNC

Number of SDC:TSG for message exchange

Number of SDC:SGC for call setup

12

D900 exchanges

TSG
0.0

TSG
0.1

SSG
0.0

SN0

TSG
1.0

TSG
1.1

SSG
1.0

SN1

TSG
0.0

TSG
0.1

TSG
0.2

TSG
0.3

SSG
0.0&0.1

SN0

TSG
1.0

TSG
1.1

TSG
1.2

TSG
1.3

SSG
1.0&1.1

SN1

TSG
0.0

TSG
0.1

TSG
0.2

TSG
0.3

TSG
0.4

TSG
0.5

TSG
0.6

TSG
0.7

SSG
SSG
0.0&0.1 0.2&0.3

SN0

TSG
1.0

TSG
1.1

TSG
1.2

TSG
1.3

TSG
1.4

TSG
1.5

TSG
1.6

TSG
1.7

SSG
SSG
1.0&1.1 1.2&1.3

SN1

SN:126LTG

SN:252LTG

SN:504LTG

Fig. 3 Capacity stages of the switching network

MN2512E6A02

Siemens

Switching Network (SN(B))

1.2.1 SN(B) Functional Units and Modules


The SN(B) is divided into the following functional units:


Time switch circuit (TSC)


A TSC can connect each incoming time slot belonging to one of the 4 connected
SDC:LTG to a random outgoing time slot on any of the 4 connected SN internal
SDCs. As each of the SDCs is always bidirectional a TSC is divided into TSC
incoming and TSC outgoing.

Link interface to LTG (LIL)


The LIL is the interface to the LTG. It is responsible for propagation time
equalization of the SDC:LTG.

Space switch SS16|16


An SS16|16 can connect any incoming time slot belonging to one of the 16
connected SDC to the outgoing time slot with the same number belonging to any
of these 16 SDC.

Space Switch SS8|15


An SS8|15 is connected to 8 SDC on one side and 15 SDC on the other side.
Each SS8|15 is divided into two subunits. One unit can connect any incoming time
slot belonging to one of the 8 SDC on one side to the outgoing time slot with the
same number belonging to one of the 15 SDC on the other side. The other
subunit can connect any incoming time slot belonging to one of the 15 SDC on
one side to the outgoing time slot with the same number belonging to one of the
8 SDC on the other side.

Link interface between TSG and SSG (LIS)


The SDC:SSG (TSG SSG) are connected to SSG and TSG via the LIS. These act
as interfaces for propagation time equalization of the individual SDC. In addition
the LIS specifies which TSG (SN0 or 1) will interoperate with which SSG (SN0 or
1). In this sense it can be compared to the LIU function inside the LTG.

Switch group control (SGC)


Each SGC controls the functional units in its TSG/SSG. To do this it interacts with
the CP via its SDC:SGC.

Link Interface to message buffer (LIM)


The interface function for the SDC:SGC to the message buffer is implemented by
means of the LIM component.

In the SN(B) the individual functional units are assigned to modules as follows:

10

2 TSC including LIL function are implemented in one TSMB module

in the TSG the LIS function for 16 SDC is implemented in one LISB module

the LIS function of the SSG is implemented with 2 SS8|15 in one SSM8B module

8 SS16|16 are implemented in one SSM16B module

LIM and SGC functions are implemented in one SGCB

MN2512E6A02

Switching Network (SN(B))

Siemens

SSG

TSG
TSMB

LISB

2x
LIL

SDC:LTG

2x
TSC

SSM8B

SSM16B

2x
LIS

LIS

SGC

SGC

LIM

LIM

SGCB

8x
SS
16|16

2x
SS8|15

SGCB

Fig. 4 Internal structure of TSG and SSG

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN2512E6A02

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

11

Switching Network (SN(B))

Siemens

1.2.2 Interconnection between Functional Units


Rules for internal connections inside the TSG:


the TSC number is the same as the number of the corresponding LISB port

the number of the TSC port is the same as the number of the corresponding LISB

Rules for internal connections inside the SSG:




the SS8|15 number is the same as the number of the corresponding SS16|16 port

the number of the SS8|15 port is the same as the number of the corresponding
SS16|16

TSGx-x
SDC:LTG
0

LIL0

TSC0

2
14

LISB0

15

TSMB-0
4

LIL1

TSC1

2
14

LISB1

15
0
56
57
58

59

LIL14

62

63

14

15

2
3

LIL15

LISB2

TSMB-7

61

TSC14

60

TSC15

14

15

LISB3

Fig. 5 Internal connections of a TSG

12

MN2512E6A02

Switching Network (SN(B))

Siemens

SSGx-x

0
1
LIS0

SS8|15
0

0
1

0
1

14

14
15

SSM8B-0
0
1
LIS1

SS8|15
1

0
1

0
1

14
15

SS16|16
0

SS16|16
1

14

SSM16B-0
0
1
LIS14

SS8|15
2

0
1

0
1
14
15

14

7
SSM8B-1
0
1
LIS15

SS8|15
3

0
1

0
1

14
15

14

0
1
14
15
0
1
0
1
LIS14

SS8|15
14

0
1

14
15

SS16|16
6

SS16|16
7

SS16|16
8

SS16|16
9

SSM16B-1

14

SSM8B-7
0
1
LIS15

SS8|15
15

0
1

0
1

14

14
15
0
1
Not used
14
15

SS16|16
14

SS16|16
15

Fig. 6 Internal connections of a SSG

MN2512E6A02

13

Siemens

Switching Network (SN(B))

Interconnection of TSG and SSG


Fig. 7 shows an example of cable connections between TSG and SSG. An SN
126LTG was selected for this example. The duplication is not shown.
TIP
Each line represents two cables. Each cable contains the wires of 16SDC:SSG for
one transmission direction.

Protection Switching Options:


Fig. 8 shows the position of the switches in the LIS functional units (in the TSG LISB
and SSG SSM8B) for the following SN configurations:


TSG and SSG in SN0 are active

TSG and SSG in SN1 are in stand by status

If an active unit fails the configuration status is changed so that all LTG remain
available.
Examples of protection switching:

14

TSG 0-0 fails:


TSG and SSG in SN1 are activated automatically, SSG0-0 changes to standby

SSG 1-0 also fails:


TSG 1-0 and SSG0-0 become active and interoperate (crossover switching)

MN2512E6A02

Switching Network (SN(B))

Siemens

LISB0

SSM8B0

LISB1

SSM8B1

LISB2

SSM8B2

LISB3

SSM8B3

TSGn-0

SSGn-0

LISB0

SSM8B4

LISB1

SSM8B5

LISB2

SSM8B6

LISB3

SSM8B7

TSGn-1

SN(B) 0 or 1

Fig. 7 Example of interconnection between TSGs and SSGs

SSG0-0

TSG0-0
SSM8B

TSMB

SS
15|8

TSCO
LIL

LISB

SSM
16B

LIS
SS
8|15

TSCI

SN(B) 0
(active)

LTG
(LIU)

SN(B) 1
(standby)
TSMB

SSM8B

TSCO
LIL

SS15|8
LISB

TSCI

TSG1-0

SSM
16B

LIS
SS8|15

SSG1-0

Fig. 8 Protection switching options

MN2512E6A02

15

Switching Network (SN(B))

Siemens

1.3 SN(B) Rack and Module Frames


Each SN rack always contains 2 SN module frames. These can be installed inside the
rack at the top or bottom. The remaining space inside the rack can be used for LTG
and/or MB.

MOLOC

101 113

137

149

161

197 209

221

233

245

257

269

281

293

305

TSMB7

TSMB6

TSMB4

LISB3

185

LISB2

173

LISB1

TSMB1
125

TSMB5

TSG(B) frame with one SN:63LTG plane

SGCB

LISB0

SSG(B) frame with one or two SSG belonging to the same SN plane

TSMB3

TSMB2

TSG(B) frame with one TSG

TSMB0

317

329

DCC

A rack always contains one of the following module frame types for redundant units
from SN0 and SN1:

341

Module frame F:TSG(B)

MOLOC

101 113

125

137

149

161

185

209

221

233

245

257

269

281

293

317

329

DCC

SSM8B7

SSM16B1
305

SSM8B6

SSM8B5

SSM8B4

SGCB

SSM8B3

SSM16B0

SSM8B2

SSM8B1

SSM8B0

SSM8B7

SSM16B1

197

SSM8B6

SSG(B)x-x

SSM8B5

SGCB
173

SSM8B4

SSM8B3

SSM16B0
SSM8B2

SSM8B1

SSM8B0

DCC

SSG(B)x-x

341

Module frame F:SSG(B)

Fig. 9 Frames for the SN(B)

16

MN2512E6A02

Switching Network (SN(B))

Fuses

Siemens

MUT01

Fuses

MUT01

F:LTGM

MUT02

F:LTGM

MUT02

F:LTGM

MUT03

F:LTGM

MUT03

F:LTGM

MUT04

F:LTGM

MUT04

F:LTGM

MUT05

F:LTGM

MUT05

SN0

F:SSG(B)

MUT06

SN0

F:TSG(B)

MUT06

SN1

F:SSG(B)

MUT07

SN1

F:TSG(B)

MUT07

R:SSG(B)LTGM

R:TSG(B)LTGM

Fig. 10 Examples of rack layouts for the SN

MN2512E6A02

17

Siemens

18

Switching Network (SN(B))

MN2512E6A02

Switching Network (SN(B))

Siemens

2 MML Commands

MN2512E6A02

19

Siemens

Switching Network (SN(B))

2.1 Interrogating the SN


Interrogating the SN

STAT SN ;
DISP TSG : SN= ;
The DISPTSG command displays the expansion data for one or both switching
network sides. It shows the number of time stage modules:
Amount of TSMs = (TSMMAX + 1) / 2

20

MN2512E6A02

Switching Network (SN(B))

Siemens

MSC2/D2MMPK1V9502-I21/000
1971 CA
MARTIN#1

98-12-18

16:08:14

3080/00226

STATSN;

EXEC'D

TSG
------0-0 ACT
0-1 PLA

SSG
------0-0 ACT

TSG
------1-0 STB
1-1 PLA

SSG
------1-0 STB

END JOB 1971

MSC2/D2MMPK1V9502-I21/000
1977 CA
MARTIN#1

98-12-18

16:08:37

3102/01025

DISPTSG:SN=X;
TSG TSMMAX
----+-----0-0
5
0-1
5
1-0
5
1-1
5
END JOB 1977

Fig. 11 Interrogation of the SN

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN2512E6A02

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

21

Siemens

Switching Network (SN(B))

2.2 Configuring SN Components


Configuring SN components

CONF SN : SN= ,OST= [ ,UNCOND= ] [ ,SUP= ] ;


CONF SSG : SN= ,SSG= ,OST= [ ,UNCOND= ] [ ,SUP= ] ;
CONF TSG : SN= ,TSG= ,OST= [ ,UNCOND= ] [ ,SUP= ] ;
TIP
It is not possible to configure a SN half to active. to change the operating status of
the SN halves, configure the active SN to STB.

22

MN2512E6A02

Switching Network (SN(B))

Siemens

ACT

STB

MBL

UNA

NAC
MSC2/D2MMPK1V9502-I21/000
2179 CA
MARTIN#1

98-12-18

16:38:35

98-12-18

16:38:41

98-12-18

16:38:44

3077/06611

CONFSN:SN=0,OST=STB;
STARTING CONFIGURATION FOR SN

-0

FROM ACT TO STB

END TEXT 2179

MSC2/D2MMPK1V9502-I21/000
2179 CA
MARTIN#1

3077/06609

CONFSN:SN=0,OST=STB;
END OF CONFIGURATION FOR SN

-0

FROM ACT TO STB

END TEXT 2179

MSC2/D2MMPK1V9502-I21/000
2179 CA
MARTIN#1
CONFSN:SN=0,OST=STB;

3076/00007
EXEC'D

END JOB 2179


Fig. 12 Configuring the SN

MN2512E6A02

23

Switching Network (SN(B))

Siemens

ACT

STB

MBL

UNA

NAC

MSC2/D2MMPK1V9502-I21/000
2191 CA
MARTIN#1

98-12-18

16:39:23

98-12-18

16:39:32

98-12-18

16:39:45

3077/06611

CONFTSG:SN=0,TSG=0,OST=MBL;
STARTING CONFIGURATION FOR TSG -0-0

FROM STB TO MBL

END TEXT 2191

MSC2/D2MMPK1V9502-I21/000
2191 CA
MARTIN#1

3077/06609

CONFTSG:SN=0,TSG=0,OST=MBL;
END OF CONFIGURATION FOR TSG -0-0

FROM STB TO MBL

END TEXT 2191

MSC2/D2MMPK1V9502-I21/000
2191 CA
MARTIN#1
CONFTSG:SN=0,TSG=0,OST=MBL;

3076/00007
EXEC'D

END JOB 2191


Fig. 13 Configuring the TSG or SSG

24

MN2512E6A02

Switching Network (SN(B))

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN2512E6A02

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

Siemens

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

25

Siemens

Switching Network (SN(B))

2.3 Diagnose SN Components


Diagnose SN components

DIAG SN : SN= ,TA= ;


DIAG SSG : SN= ,SSG= ,TA= ;
DIAG TSG : SN= ,TSG= ,TA= ;

26

MN2512E6A02

Switching Network (SN(B))

Siemens

MSC2/D2MMPK1V9502-I21/000
2437 CA
MARTIN#1

98-12-18

17:04:14

3085/00006

DIAGSN:SN=0,TA=ALL;

STARTED

END TEXT 2437

MSC2/D2MMPK1V9502-I21/000
2437 CA
MARTIN#1

98-12-18

17:04:43

3076/01749

DIAGSN:SN=0,TA=ALL;

EXEC'D

RESULT = NO FAULT DETECTED


END JOB 2437

MSC2/D2MMPK1V9502-I21/000
2479 CA
MARTIN#1

98-12-18

17:10:41

3085/00006

DIAGSSG:SN=0,SSG=0,TA=SSM,SUBUNT=SSM-0;

STARTED

END TEXT 2479


MSC2/D2MMPK1V9502-I21/000
2479 CA
MARTIN#1

98-12-18

17:10:48

3076/01749

DIAGSSG:SN=0,SSG=0,TA=SSM,SUBUNT=SSM-0;

EXEC'D

RESULT = NO FAULT DETECTED


END JOB 2479
Fig. 14 Diagnose the SN

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

MN2512E6A02

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

27

Siemens

28

Switching Network (SN(B))

MN2512E6A02

Switching Network (SN(B))

Siemens

3 Exercises

MN2512E6A02

29

Siemens

30

Switching Network (SN(B))

MN2512E6A02

Switching Network (SN(B))

Siemens

Exercise 1
Title:

Questions about the Switching Network)

Objectives:

Repetition of the topics in this chapter

Pre-requisite:

The student can explain the Switching Network

Task
Please answer the following questions

Query


What are the tasks of the switching network ?

102 LTGs and one CCNC are to be connected to the switching network. How
many TSMB modules are required ?

Which is the bit rate of the SN internal highways ?

Which capacity stages of a SN do you know ?

What is the time slot 0 between SN and LTG used for ?

Which unit performs the through-connection of a path in SN ?

What type of connection does the SN realize ?

What is the effect of a fault in the SN ?

MN2512E6A02

31

Siemens

32

Switching Network (SN(B))

MN2512E6A02

Switching Network (SN(B))

Siemens

Exercise 2
Title:

Standard HW Fault Clearance SN: Hands On Training

Objectives:

The participant is able to

Pre-requisite:

perform the SN fault clearance tasks of a network element


manager

Training exchange or Computer Based Simulator is available

MMN, CML and ECD

Task
Perform fault clearance for a given example!

Query
List the MMN procedure(s) which have to be performed!

MN2512E6A02

33

Siemens

34

Switching Network (SN(B))

MN2512E6A02

Switching Network (SN(B))

Siemens

4 Solutions

MN2512E6A02

35

Siemens

36

Switching Network (SN(B))

MN2512E6A02

Switching Network (SN(B))

Siemens

Solution 1
Title:

Questions about the Switching Network)

Objectives:

Repetition of the topics in this chapter

Pre-requisite:

The student can explain the Switching Network

Task
Please answer the following questions

Query


What are the tasks of the switching network ?

Through-connection of the speech channels. Emergency switchover.




102 LTGs and one CCNC are to be connected to the switching network. How
many TSMB modules are required ?

102 (LTG) + 1(CCNC) + 2(MBU) = 105 ; 105/8 => 14 TSMB




Which is the bit rate of the SN internal highways ?

8Mbps


Which capacity stages of a SN do you know ?

SN:63LTG, SN:126LTG, SN:256LTG, SN:504LTG




What is the time slot 0 between SN and LTG used for ?

Exclusively for internal signaling purposes (message channel)




Which unit performs the through-connection of a path in SN ?

SGCB upon commands it receives from the CP




What type of connection does the SN realize ?

Single channel, broadcast, nailed-up-connections




What is the effect of a fault in the SN ?

SN performs the switchover to standby plane

MN2512E6A02