Objectives
The participant is able to
name the units of the SN(B) and their functions
localize the modules of the SN(B)
maintain the SN
operate the SN
Contents
1
1.1
1.2
1.3
2
2.1
2.2
2.3
3
4
Functional Description
Introduction
Hardware
SN(B) Rack and Module Frames
MML Commands
Interrogating the SN
Configuring SN Components
Diagnose SN Components
Exercises
Solutions
MN2512E6A02
3
4
6
16
19
20
22
26
29
35
Siemens
MN2512E6A02
Siemens
1 Functional Description
MN2512E6A02
Siemens
1.1 Introduction
The switching network SN is the link inside a node for:
the EWSD internal message exchange between LTG, CCNC and CP control units
via fixed message channels MCH
The switching network is fully duplicated (SN0 and SN1). For traffic connections, one
is the active, the other one the standby side. All calls are always simultaneously
through connected via both SN sides while the LTG only through connects user
channel information received from the active SN to the PCM links. If the active SN
fails the system switches to the standby SN without any loss.
Through connection in the SN occurs in accordance with the "time space time"
principle (change of time slot change of space slot change of time slot). Each
through connection ensures a transparent bidirectional 64kbit/s path through the SN.
In addition to temporary through connections (transient calls), the following nonswitched connections also apply:
through connection of message channels between LTG control units and the
message buffer (permanently specified by CP software).
Every connection between the SN and other functional units use secondary digital
carrier lines (SDC) with a bit rate of 8192kbps (mostly called 8Mbit system or
highways), carrying 128 standard 64kbps time slots (numbers 0-127).
MN2512E6A02
Siemens
LTG1
SN1
SN0
CCNC
CCS7 signaling, internal messages
Coordination Area
Internal messages
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN2512E6A02
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Siemens
1.2 Hardware
The SN for EWSD systems is available in different capacity stages. With the
exception of the small switching network for a maximum of 63 LTGs (combined
space-time stages), each SN consists of the subunits time stage group (TSG) and
space stage group (SSG).
Time Stage Group (TSG):
Each TSG connects the SDC to/from the LTG, CCNC, and MB. 64 of this SDCs can
be connected to each TSG. An SN is made of a maximum of 8 duplicated TSG. Each
TSG contains a switch group control (SGC) which is connected to the CP via the
message buffer (MB) with an own SDC line. The SGC receives setting instructions
for temporary or fixed bidirectional 64kbps through connections from the CP. The
SGC implements through connections by setting the individual time stage modules
(TSM) in a TSG. Inside a TSG each TSM can change the position in time and space of
any time slot arbitrarily for a group of 8 connected SDC.
Space Stage Group (SSG):
The SSG through connects a call between TSM inside the same or different TSG. An
SN consists of a maximum of 4 duplicated SSG. Inside the SSG is a switch group
control (SGC) connected to the CP via the message buffer (MB). The SGC receives
setting instructions for temporary or fixed bidirectional 64kbps through connections
from the CP. The SGC implements through connections by setting the individual
space stage modules (SSM) in an SSG. Each SSM can change the space slot of the
time slot for connected SDC arbitrarily.
External and internal connections
The following types of secondary digital carriers (SDC) with 8Mbps form the internal
and external interfaces of the SN:
SDC:LTG between TSG and maximum 63 LTG for circuit connections (time slots
1-127) and for message exchange between the LTG GP control unit and the CP
(message channel to time slot 0). Any TSG port can be used except 0, which is
reserved for the SDC:TSG to the message buffer.
one or two SDC:CCNC to through connect CCS7 messages between the CCNC
and the signaling channels in the PCM links. Can use any TSG port except 0 (MB).
one SDC:TSG between TSG and MB to transfer the message channel for all LTG
in this TSG to the CP. Always connected to port 0 of every TSG.
one SDC:SGC between the SGC control unit in a TSG/SSG and the MB to transfer
the CP setting instructions to TSG/SSG
The individual TSG and SSG are connected to each other via SDC:SSG
MN2512E6A02
Siemens
Internal
Interfaces
SN 0 or SN 1
SDC:LTG
Time
Stage
Group
LTG1
SDC:LTG
LTGn
SDC:SSG
SDC:CCNC
Space
Stage
Group
SDC:SSG
CCNC
CP
SDC:SSG
MB
SDC:TSG
MBU
SDC:SGC
SGC
MBU
SDC:SGC
SGC
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN2512E6A02
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Siemens
Capacity stages
As the SN is available in different increments the actual size of the switching
network can be matched to the expected traffic volume in an exchange. The volume
of traffic to be through connected measured in Erlangs is used as the dimensional
size.
TIP
In addition to the increments listed the special implementation of SN for 31 LTG and
for 63 LTG is also available for small EWSD.
Capacity / space requirements for SN increments:
TIP
Mobile systems are not fully equipped with all possible LTGs. Because of the much
higher signaling load in a PLMN, the amount of internal messages would be too high
for the message buffer. Fig. 3 shows the capacity stages of EWSD and D900
systems.
MN2512E6A02
Siemens
SN126
SN252
SN504
126
252
504
12
SN126
SN252
SN504
62
124
248
12
D900 exchanges
TSG
0.0
TSG
0.1
SSG
0.0
SN0
TSG
1.0
TSG
1.1
SSG
1.0
SN1
TSG
0.0
TSG
0.1
TSG
0.2
TSG
0.3
SSG
0.0&0.1
SN0
TSG
1.0
TSG
1.1
TSG
1.2
TSG
1.3
SSG
1.0&1.1
SN1
TSG
0.0
TSG
0.1
TSG
0.2
TSG
0.3
TSG
0.4
TSG
0.5
TSG
0.6
TSG
0.7
SSG
SSG
0.0&0.1 0.2&0.3
SN0
TSG
1.0
TSG
1.1
TSG
1.2
TSG
1.3
TSG
1.4
TSG
1.5
TSG
1.6
TSG
1.7
SSG
SSG
1.0&1.1 1.2&1.3
SN1
SN:126LTG
SN:252LTG
SN:504LTG
MN2512E6A02
Siemens
In the SN(B) the individual functional units are assigned to modules as follows:
10
in the TSG the LIS function for 16 SDC is implemented in one LISB module
the LIS function of the SSG is implemented with 2 SS8|15 in one SSM8B module
MN2512E6A02
Siemens
SSG
TSG
TSMB
LISB
2x
LIL
SDC:LTG
2x
TSC
SSM8B
SSM16B
2x
LIS
LIS
SGC
SGC
LIM
LIM
SGCB
8x
SS
16|16
2x
SS8|15
SGCB
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN2512E6A02
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
11
Siemens
the TSC number is the same as the number of the corresponding LISB port
the number of the TSC port is the same as the number of the corresponding LISB
the SS8|15 number is the same as the number of the corresponding SS16|16 port
the number of the SS8|15 port is the same as the number of the corresponding
SS16|16
TSGx-x
SDC:LTG
0
LIL0
TSC0
2
14
LISB0
15
TSMB-0
4
LIL1
TSC1
2
14
LISB1
15
0
56
57
58
59
LIL14
62
63
14
15
2
3
LIL15
LISB2
TSMB-7
61
TSC14
60
TSC15
14
15
LISB3
12
MN2512E6A02
Siemens
SSGx-x
0
1
LIS0
SS8|15
0
0
1
0
1
14
14
15
SSM8B-0
0
1
LIS1
SS8|15
1
0
1
0
1
14
15
SS16|16
0
SS16|16
1
14
SSM16B-0
0
1
LIS14
SS8|15
2
0
1
0
1
14
15
14
7
SSM8B-1
0
1
LIS15
SS8|15
3
0
1
0
1
14
15
14
0
1
14
15
0
1
0
1
LIS14
SS8|15
14
0
1
14
15
SS16|16
6
SS16|16
7
SS16|16
8
SS16|16
9
SSM16B-1
14
SSM8B-7
0
1
LIS15
SS8|15
15
0
1
0
1
14
14
15
0
1
Not used
14
15
SS16|16
14
SS16|16
15
MN2512E6A02
13
Siemens
If an active unit fails the configuration status is changed so that all LTG remain
available.
Examples of protection switching:
14
MN2512E6A02
Siemens
LISB0
SSM8B0
LISB1
SSM8B1
LISB2
SSM8B2
LISB3
SSM8B3
TSGn-0
SSGn-0
LISB0
SSM8B4
LISB1
SSM8B5
LISB2
SSM8B6
LISB3
SSM8B7
TSGn-1
SN(B) 0 or 1
SSG0-0
TSG0-0
SSM8B
TSMB
SS
15|8
TSCO
LIL
LISB
SSM
16B
LIS
SS
8|15
TSCI
SN(B) 0
(active)
LTG
(LIU)
SN(B) 1
(standby)
TSMB
SSM8B
TSCO
LIL
SS15|8
LISB
TSCI
TSG1-0
SSM
16B
LIS
SS8|15
SSG1-0
MN2512E6A02
15
Siemens
MOLOC
101 113
137
149
161
197 209
221
233
245
257
269
281
293
305
TSMB7
TSMB6
TSMB4
LISB3
185
LISB2
173
LISB1
TSMB1
125
TSMB5
SGCB
LISB0
SSG(B) frame with one or two SSG belonging to the same SN plane
TSMB3
TSMB2
TSMB0
317
329
DCC
A rack always contains one of the following module frame types for redundant units
from SN0 and SN1:
341
MOLOC
101 113
125
137
149
161
185
209
221
233
245
257
269
281
293
317
329
DCC
SSM8B7
SSM16B1
305
SSM8B6
SSM8B5
SSM8B4
SGCB
SSM8B3
SSM16B0
SSM8B2
SSM8B1
SSM8B0
SSM8B7
SSM16B1
197
SSM8B6
SSG(B)x-x
SSM8B5
SGCB
173
SSM8B4
SSM8B3
SSM16B0
SSM8B2
SSM8B1
SSM8B0
DCC
SSG(B)x-x
341
16
MN2512E6A02
Fuses
Siemens
MUT01
Fuses
MUT01
F:LTGM
MUT02
F:LTGM
MUT02
F:LTGM
MUT03
F:LTGM
MUT03
F:LTGM
MUT04
F:LTGM
MUT04
F:LTGM
MUT05
F:LTGM
MUT05
SN0
F:SSG(B)
MUT06
SN0
F:TSG(B)
MUT06
SN1
F:SSG(B)
MUT07
SN1
F:TSG(B)
MUT07
R:SSG(B)LTGM
R:TSG(B)LTGM
MN2512E6A02
17
Siemens
18
MN2512E6A02
Siemens
2 MML Commands
MN2512E6A02
19
Siemens
STAT SN ;
DISP TSG : SN= ;
The DISPTSG command displays the expansion data for one or both switching
network sides. It shows the number of time stage modules:
Amount of TSMs = (TSMMAX + 1) / 2
20
MN2512E6A02
Siemens
MSC2/D2MMPK1V9502-I21/000
1971 CA
MARTIN#1
98-12-18
16:08:14
3080/00226
STATSN;
EXEC'D
TSG
------0-0 ACT
0-1 PLA
SSG
------0-0 ACT
TSG
------1-0 STB
1-1 PLA
SSG
------1-0 STB
MSC2/D2MMPK1V9502-I21/000
1977 CA
MARTIN#1
98-12-18
16:08:37
3102/01025
DISPTSG:SN=X;
TSG TSMMAX
----+-----0-0
5
0-1
5
1-0
5
1-1
5
END JOB 1977
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN2512E6A02
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
21
Siemens
22
MN2512E6A02
Siemens
ACT
STB
MBL
UNA
NAC
MSC2/D2MMPK1V9502-I21/000
2179 CA
MARTIN#1
98-12-18
16:38:35
98-12-18
16:38:41
98-12-18
16:38:44
3077/06611
CONFSN:SN=0,OST=STB;
STARTING CONFIGURATION FOR SN
-0
MSC2/D2MMPK1V9502-I21/000
2179 CA
MARTIN#1
3077/06609
CONFSN:SN=0,OST=STB;
END OF CONFIGURATION FOR SN
-0
MSC2/D2MMPK1V9502-I21/000
2179 CA
MARTIN#1
CONFSN:SN=0,OST=STB;
3076/00007
EXEC'D
MN2512E6A02
23
Siemens
ACT
STB
MBL
UNA
NAC
MSC2/D2MMPK1V9502-I21/000
2191 CA
MARTIN#1
98-12-18
16:39:23
98-12-18
16:39:32
98-12-18
16:39:45
3077/06611
CONFTSG:SN=0,TSG=0,OST=MBL;
STARTING CONFIGURATION FOR TSG -0-0
MSC2/D2MMPK1V9502-I21/000
2191 CA
MARTIN#1
3077/06609
CONFTSG:SN=0,TSG=0,OST=MBL;
END OF CONFIGURATION FOR TSG -0-0
MSC2/D2MMPK1V9502-I21/000
2191 CA
MARTIN#1
CONFTSG:SN=0,TSG=0,OST=MBL;
3076/00007
EXEC'D
24
MN2512E6A02
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN2512E6A02
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Siemens
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
25
Siemens
26
MN2512E6A02
Siemens
MSC2/D2MMPK1V9502-I21/000
2437 CA
MARTIN#1
98-12-18
17:04:14
3085/00006
DIAGSN:SN=0,TA=ALL;
STARTED
MSC2/D2MMPK1V9502-I21/000
2437 CA
MARTIN#1
98-12-18
17:04:43
3076/01749
DIAGSN:SN=0,TA=ALL;
EXEC'D
MSC2/D2MMPK1V9502-I21/000
2479 CA
MARTIN#1
98-12-18
17:10:41
3085/00006
DIAGSSG:SN=0,SSG=0,TA=SSM,SUBUNT=SSM-0;
STARTED
98-12-18
17:10:48
3076/01749
DIAGSSG:SN=0,SSG=0,TA=SSM,SUBUNT=SSM-0;
EXEC'D
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MN2512E6A02
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
27
Siemens
28
MN2512E6A02
Siemens
3 Exercises
MN2512E6A02
29
Siemens
30
MN2512E6A02
Siemens
Exercise 1
Title:
Objectives:
Pre-requisite:
Task
Please answer the following questions
Query
102 LTGs and one CCNC are to be connected to the switching network. How
many TSMB modules are required ?
MN2512E6A02
31
Siemens
32
MN2512E6A02
Siemens
Exercise 2
Title:
Objectives:
Pre-requisite:
Task
Perform fault clearance for a given example!
Query
List the MMN procedure(s) which have to be performed!
MN2512E6A02
33
Siemens
34
MN2512E6A02
Siemens
4 Solutions
MN2512E6A02
35
Siemens
36
MN2512E6A02
Siemens
Solution 1
Title:
Objectives:
Pre-requisite:
Task
Please answer the following questions
Query
102 LTGs and one CCNC are to be connected to the switching network. How
many TSMB modules are required ?
8Mbps
MN2512E6A02
37
Siemens
38
MN2512E6A02