Documente Academic
Documente Profesional
Documente Cultură
Feature
Level
Class
Range
Units
Commands
DL
UL
BSPWRB
CELL
RSITE
TG
Common data
Common data
Common data
Common data
Common data
Common data
BSC
BSC
CELL
CELL
CELL
CELL
FIXED
FIXED
VARIABLE
FIXED
FIXED
VARIABLE
-12 to 12
-12 to 12
0 to 63
1 to 7 characters except ALL
3 to 15 characters
0 to 511
dB
dB
dB
RRLLC, RRLLP 0
RRLLC, RRLLP 0
RLCPC, RLCPP
RLDEI
RLDEI
RXMOI,
RXMOC,
RXMSC,
RXESE, RXESI,
RXTCI, RXTCE,
RXBLE, RXBLI,
RXPLI, RXPLE,
RXAPI, RXAPE,
RXMOP.
CGI
Common data
CELL
FIXED
RLDEC, RLDEP
MCC
MNC
LAC
CI
NCC
BCC
BCCHNO
Common data
Common data
Common data
Common data
Common data
Common data
Common data
CELL
CELL
CELL
CELL
CELL
CELL
CELL
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
3 digits
2 or 3 digits
1 to 65535
0 to 65535
0 to 7
0 to 7
128 to 251 (GSM 800)
512 to 810 (GSM 1900)
RLDEC, RLDEP
RLDEC, RLDEP
RLDEC, RLDEP
RLDEC, RLDEP
RLDEC, RLDEP
RLDEC, RLDEP
RLDEC, RLDEP
310
410
BCCHTYPE
Common data
CELL
FIXED
AGBLK
Common data
CELL
FIXED
0 to 2 (COMB, COMBC)
0 to 7 (NCOMB)
RLDEC, RLDEP 1
MFRMS
Common data
CELL
FIXED
2 to 9
CCCH
RLDEC, RLDEP 6
multiframes
FNOFFSET
Common data
CELL
FIXED
0 to 1325
TDMA
frames
RLDEC, RLDEP 0
ECSC
SCTYPE
MNCDIGITHAND
TSC
MSTXPWR
Common data
Common data
Common data
Common data
Common data
CELL
CELL
BSC
CELL
CELL
FIXED
FIXED
FIXED
FIXED
VARIABLE
NO, YES
UL, OL
0 to 2
0 to 7
13 to 43 odd values (GSM 800)
4 to 30 even values (GSM 1900)
RLSBC, RLSBP NO
RLDSI
RAEPC, RAEPP 0
RLDTC, RLDTP Set to same as BCC
RLCPC, RLCPP
YES
BSPWRT
CHGR
Common data
Common data
CELL
CELL
VARIABLE
FIXED
0 to 63
0 to 15
STATE
NUMREQBPC
Common data
Common data
CELL
CELL
FIXED
FIXED
ACTIVE, HALTED
8 to 128 in steps of 8, SYSDEF
ARFCN
dBm
dBm
Ericsson Default
RLCPC, RLCPP
RLCCC,
0
RLDGI , RLCFP
RLSTC, RLSTP
RLBDC, RLBDP SYSDEF
Cingular
Recommendation
0
0
0 to 7
0 to 7
12 to 15 BCCH's
2
Set to same as BCC
30 (GSM1900)
33 (GSM800)
1,2,3
ACTIVE
8 X number of TRUs in
channel group
Page 1 of 39
Parameter
Feature
Level
Class
Range
Units
Commands
Ericsson Default
Cingular
Recommendation
DCHNO
Common data
CELL
FIXED
ARFCN
RLCFI, RLCFE,
RLCFP
BCCD
Common data
CELL
VARIABLE
YES, NO
RLCFI, RLCFE,
RLCFP
YES
YES
SDCCH
Common data
CELL
FIXED
0 to 16
0 to 7 if CCHPOS = BCCH
0 to 3 if CCHPOS = BCCH and cell is
extended range
RLCCC, RLCFP 1
CCHPOS
TN
Common data
Common data
CELL
CELL
FIXED
FIXED
BCCH, TN
0 to 3, 0 or 2 (extended range)
RLCCC, RLCFP TN
RLCCC, RLCFP 2
CBCH
TRADROPLEVEL
Common data
Common data
CELL
BSC
FIXED
FIXED
YES, NO
0, 10 to 60, 110 to 160
RLCCC, RLCFP NO
RAEPC, RAEPP.
NO
25 - Alarm = A1
125 - Alarm = A3
TRADROPNOTRAF
Common data
BSC
FIXED
RAEPC, RAEPP.
25 or 15
CELLR
CELL
VARIABLE
RLNRI, RLNRC,
RLNRE, RLNRP
CTYPE
CELL
VARIABLE
EXT, Omitted
RLDEI, RLLHP,
RLDEP
RELATION
CS
CELL
CELL
VARIABLE
FIXED
SINGLE, OMITTED
YES, NO
RLNRI
OMITTED
RLNRC, RLNRP NO
ACCMIN
CELL
VARIABLE
47 to 110
dBm
CCHPWR
CELL
FIXED
dBm
RLSSC, RLSSP
30 (GSM1900)
33 (GSM800)
CRH
NCCPERM
SIMSG
CELL
CELL
CELL
FIXED
FIXED
FIXED
0 to 14 in steps of 2
0 to 7
1, 7, 8
dB
RLSSC, RLSSP 4
RLSSC, RLSSP
RLSMC, RLSMP SIMSG=1 MSGDIST=ON
SIMSG=7 MSGDIST=OFF
SIMSG=8 MSGDIST=OFF
4
0,1,2,3,4,5,6,7
1, ON
7, OFF
8, OFF
MSGDIST
CELL
FIXED
ON, OFF
CB
CBQ
CELL
CELL
FIXED
FIXED
YES, NO
HIGH, LOW
RLSBC, RLSBP NO
RLSBC, RLSBP HIGH
1 TRU = 0 (COMB)
2 TRU = 1 (NCOMB)
3 TRU = 1 (NCOMB)
4 TRU = 1 (NCOMB)
5 TRU = 2 (NCOMB)
6 TRU = 2 (NCOMB)
7 TRU = 3 (NCOMB)
8 TRU = 4 (NCOMB)
9 TRU = 4 (NCOMB)
10 TRU = 4 (NCOMB)
11 TRU = 4 (NCOMB)
12 TRU = 4 (NCOMB)
CG0: 1 to 7
CG1: 0 to 7
Omitted
YES (Co-sited)
NO (Not co-sited)
110
NO
HIGH
Page 2 of 39
Parameter
Feature
Level
Class
Range
Units
Commands
Ericsson Default
Cingular
Recommendation
ACC
MAXRET
TX
ATT
T3212
CELL
CELL
CELL
CELL
CELL
FIXED
FIXED
FIXED
FIXED
FIXED
0 to 15, CLEAR
1, 2, 4, 7
3 to 12, 14, 16, 20, 25, 32, 50
YES, NO
0 to 255
Deci hours
RLSBC, RLSBP
RLSBC, RLSBP
RLSBC, RLSBP
RLSBC, RLSBP
RLSBC, RLSBP
CLEAR
4
50
YES
40
CLEAR
7
32
YES
9 for standard cells
4 for MSC/BSC border
cells
CRO
CELL
FIXED
0 to 63
dB
RLSBC, RLSBP 0
0 for GSM1900
3 for GSM850
TO
PT
FASTASSIGN
NOOFPHYSINFOMSG
TIMER3105
EVALTYPE
TINIT
CELL
CELL
BSC
BSC
BSC
BSC
BSC
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
0 to 7
0 to 31
0, 1
0 to 254
0 to 254
1, 3
0 to 120
dB
RLSBC, RLSBP
RLSBC, RLSBP
RAEPC, RAEPP
RAEPC, RAEPP
RAEPC, RAEPP
RLLBC, RLLBP
RLLBC, RLLBP
0
0
0
35
4
1
10
0
0
0
35
6
3
TALLOC
Locating
BSC
FIXED
0 to 120
SACCH
periods
RLLBC, RLLBP
TURGEN
Locating
BSC
FIXED
0 to 120
SACCH
periods
RLLBC, RLLBP
TAAVELEN
SSEVALSD
QEVALSD
SSEVALSI
QEVALSI
SSLENSD
Locating
Locating
Locating
Locating
Locating
Locating
BSC
CELL
CELL
CELL
CELL
CELL
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
1 to 20
1 to 9
1 to 9
1 to 9
1 to 9
1 to 20
RLLBC, RLLBP
RLLFC, RLLFP
RLLFC, RLLFP
RLLFC, RLLFP
RLLFC, RLLFP
RLLFC, RLLFP
4
6
6
6
6
10
QLENSD
Locating
CELL
FIXED
1 to 20
SACCH
periods
RLLFC, RLLFP
10
10
SSLENSI
Locating
CELL
FIXED
1 to 20
SACCH
periods
RLLFC, RLLFP
QLENSI
Locating
CELL
FIXED
1 to 20
SACCH
periods
RLLFC, RLLFP
SSRAMPSD
Locating
CELL
FIXED
1 to 20
SACCH
periods
RLLFC, RLLFP
SSRAMPSI
Locating
CELL
FIXED
1 to 20
SACCH
periods
RLLFC, RLLFP
MISSNM
BSPWR
MSRXMIN
Locating
Locating
Locating
CELL
CELL
CELL
FIXED
VARIABLE
FIXED
0 to 18
0 to 80
0 to 150
BSRXMIN
Locating
CELL
FIXED
0 to 150
10 ms
SACCH
periods
SACCH
periods
dBm
dBm
(negative)
dBm
(negative)
10
2
2
4
6
6
6
6
10
RLLOC, RLLOP 3
RLLOC, RLLOP
RLLOC, RLLOP
3
variable
104
RLLOC, RLLOP
150
Page 3 of 39
Parameter
Feature
Level
Class
Range
Units
Commands
Ericsson Default
Cingular
Recommendation
MSRXSUFF
Locating
CELL
FIXED
0 to 150
dBm
(negative)
RLLOC, RLLOP
0 or 150
BSRXSUFF
Locating
CELL
FIXED
0 to 150
dBm
(negative)
RLLOC, RLLOP
150
BSTXPWR
KHYST
LHYST
TRHYST
KOFFSET
LOFFSET
TROFFSET
HIHYST
LOHYST
HYSTSEP
Locating
Locating
Locating
Locating
Locating
Locating
Locating
Locating
Locating
Locating
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
0 to 80
0 to 63
0 to 63
0 to 63
63 to 63
63 to 63
63 to 63
0 to 63
0 to 63
0 to 150
dBm
dB
dB
dB
dB
dB
dB
dB
dB
dBm
(negative)
RLLOC, RLLOP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
3
3
2
0
0
0
5
3
90
OFFSET
BADQDL
BADQUL
LOWSSDL
Locating
Locating
Locating
Locating
CELL
BSC
BSC
BSC
VARIABLE
FIXED
FIXED
FIXED
63 to 63
0 to 100
0 to 100
47 to 110
dB
dtqu
dtqu
dBm
(negative)
RLNRC, RLNRP
RAEPC, RAEPP
RAEPC, RAEPP
RAEPC, RAEPP
0
55
55
104
variable
3
3
2
0
0
0
5
3
70
0
55
55
102, 104
LOWSSUL
Locating
BSC
FIXED
47 to 110
dBm
(negative)
TALIM
Locating
CELL
VARIABLE
0 to 63 (normal range)
0 to 219 (extended range)
Bit periods
(bp)
RLLUC, RLLUP
62
62
PSSBQ
PSSTA
PTIMBQ
PTIMTA
BQOFFSET
BQOFFSETAFR
EXTPEN
QLIMDL
Locating
Locating
Locating
Locating
Locating
Locating
Locating
Locating
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
FIXED
FIXED
FIXED
FIXED
VARIABLE
VARIABLE
FIXED
VARIABLE
0 to 63
0 to 63
0 to 600
0 to 600
0 to 63
0 to 63
ON, OFF
0 to 100
dB
dB
s
s
dB
dB
dtqu
RLLPC, RLLPP
RLLPC, RLLPP
RLLPC, RLLPP
RLLPC, RLLPP
RLNRC, RLNRP
RLNRC, RLNRP
RLLOC, RLLOP
RLLUC, RLLUP
10
63
10
10
3
3
OFF
55
7
63
15
30
3
3
ON
45 non hopping
55 hopping
QLIMDLAFR
Locating
CELL
VARIABLE
0 to 100
dtqu
RLLUC, RLLUP
55
55 non hopping
65 hopping
QLIMUL
Locating
CELL
VARIABLE
0 to 100
dtqu
RLLUC, RLLUP
55
45 non hopping
55 hopping
QLIMULAFR
Locating
CELL
VARIABLE
0 to 100
dtqu
RLLUC, RLLUP
55
55 non hopping
65 hopping
PSSHF
PTIMHF
IBHOSICH
IHOSICH
SCHO
CELLQ
Locating
Locating
Locating
Locating
Locating
Locating
CELL
CELL
BSC
BSC
CELL
CELL
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
0 to 63
0 to 600
ON, OFF
ON, OFF
ON, OFF
HIGH, LOW
dB
s
RLLPC, RLLPP
RLLPC, RLLPP
RLLBC, RLLBP
RLLBC, RLLBP
RLLOC, RLLOP
RLLUC, RLLUP
63
5
OFF
OFF
OFF
HIGH
63
5
OFF
OFF
ON
HIGH
109
Page 4 of 39
Parameter
Feature
Level
Class
Range
Units
Commands
Ericsson Default
Cingular
Recommendation
MAXTA
Locating
CELL
FIXED
0 to 63 (normal range)
0 to 219 (extended range)
Bit periods
(bp)
RLLDC, RLLDP
63
63
RLINKUP
Locating
CELL
VARIABLE
1 to 63
SACCH
periods
RLLDC, RLLDP
16
32
RLINKT
Locating
CELL
VARIABLE
1 to 63
SACCH
periods
RLSSC, RLSSP 16
32
HPBSTATE
Locating
CELL
FIXED
ACTIVE, INACTIVE
ACTIVE
CHALLOC
Channel administration /
Immediate assignment on TCH
BSC
FIXED
0 to 2
RAEPC, RAEPP 0
EBANDINCLUDED
Channel administration /
Immediate assignment on TCH
BSC
FIXED
0 and 1
RAEPC, RAEPP 0
MAXCHDATARATE
Channel administration /
Immediate assignment on TCH
BSC
FIXED
96 and 144
RAEPC, RAEPP 96
96
SPEECHVERUSED
Channel administration /
Immediate assignment on TCH
BSC
FIXED
0 and 1
RAEPC, RAEPP 1
BSCMC
Channel administration /
Immediate assignment on TCH
BSC
FIXED
ON, OFF
RLCDC ,
RLCDP
OFF
OFF
CMDR
Channel administration /
Immediate assignment on TCH
CELL
FIXED
96 and 144
RLDRC ,
RLDRP
144
144
CHAP
Channel administration /
Immediate assignment on TCH
CELL
FIXED
0 to 10
RLHPC, RLHPP 0
BCCH on overlay 6 or
8, otherwise 0 or 1.
Multiband cell = 8.
SAS
Channel administration /
Immediate assignment on TCH
CELL
FIXED
QUALITY
NECI
Channel administration /
Immediate assignment on TCH
CELL
FIXED
0 and 1
RLSSC, RLSSP 0
MC
Channel administration /
Immediate assignment on TCH
CELL
FIXED
ON, OFF
RLCDC ,
RLCDP
OFF
CHCODING
GPRS/EGPRS Channel
Administration
BSC
FIXED
CS-1 or CS-2
RAEPC, RAEPP 2
GPRSNWMODE
GPRS/EGPRS Channel
Administration
BSC
FIXED
0 to 3
RAEPC, RAEPP 2
GPRSPRIO
GPRS/EGPRS Channel
Administration
BSC
FIXED
0 to 63
RAEPC, RAEPP 0
PILTIMER
GPRS/EGPRS Channel
Administration
BSC
FIXED
1 to 3600
RAEPC, RAEPP 20
10
EGPRSBPCLIMIT
GPRS/EGPRS Channel
Administration
BSC
FIXED
0 to 8160
BPC's
DBTSP
ONDEMANDGPHDEV
GPRS/EGPRS Channel
Administration
BSC
FIXED
1 and 256
RAEPC, RAEPP 20
20
BSC
FIXED
0 to 63
RAEPC, RAEPP 5
PSETCHKPERIOD
BSC
VARIABLE
0 to 60
RAEPC, RAEPP 5
GPRS/EGPRS Channel
Administration
min
OFF
Page 5 of 39
Parameter
Feature
Level
Class
Range
Units
Commands
Ericsson Default
TBFDLLIMIT
GPRS/EGPRS Channel
Administration
BSC
FIXED
1 to 8
RAEPC, RAEPP 2
TBFULLIMIT
GPRS/EGPRS Channel
Administration
BSC
FIXED
1 to 6
RAEPC, RAEPP 2
NACCACT
GPRS/EGPRS Channel
Administration
BSC
FIXED
0 or 1
RAEPC, RAEPP 1
PDCHPREEMPT
GPRS/EGPRS Channel
Administration
BSC
FIXED
0 to 4
GPRSSUP
GPRS/EGPRS Channel
Administration
CELL
FIXED
ON, OFF
ON
FPDCH
GPRS/EGPRS Channel
Administration
CELL
FIXED
0 to 8
0 to 4 (extended range)
RLGSC, RLGSP 0
SCALLOC
GPRS/EGPRS Channel
Administration
CELL
FIXED
RAEPC, RAEPP UL
BOTHUL (FPDCH in
Underlaid)
BOTHOL (FPDCH in
Overlaid)
PDCHALLOC
GPRS/EGPRS Channel
Administration
CELL
FIXED
FIRST
PSKONBCCH
GPRS/EGPRS Channel
Administration
CELL
FIXED
ENABLED, DISABLED
ENABLED
NUMREQCS3CS4BPC
GPRS/EGPRS Channel
Administration
CELL
FIXED
0 to 128
RLBDC, RLBDP 0
NUMREQEGPRSBPC
GPRS/EGPRS Channel
Administration
CELL
FIXED
0 to 128
RLBDC, RLBDP 0
TN7BCCH
GPRS/EGPRS Channel
Administration
CELL
FIXED
EGPRS, GPRS
GPRS
GPRSEDAACT
GPRS/EGPRS Channel
Administration
BSC
FIXED
0 or 1
RAEPC, RAEPP 0
PULSCHEDINT
GPRS/EGPRS Channel
Administration
BSC
FIXED
0 to 10, 99
RAEPC, RAEPP 0
DMPSTATE
CELL
FIXED
ACTIVE or INACTIVE
RLPCI, RLPCE,
RLPCP
INACTIVE
ACTIVE
AMRPCSTATE
CELL
FIXED
ACTIVE or INACTIVE
RLAPI, RLAPE,
RLAPP
INACTIVE
ACTIVE
SSDESUL
CELL
VARIABLE
47 to 110
dBm
(negative)
RLPCC, RLPCP 85
104
SSDESULAFR
CELL
VARIABLE
47 to 110
dBm
(negative)
RLAPC, RLAPP 85
104
SSLENUL
CELL
FIXED
3 to 15
SACCH
periods
RLPCC, RLPCP 5
LCOMPUL
QDESUL
QDESULAFR
QLENUL
CELL
CELL
CELL
CELL
VARIABLE
VARIABLE
VARIABLE
FIXED
0 to 100
0 to 70
0 to 70
1 to 20
%
dtqu
dtqu
SACCH
periods
RLPCC, RLPCP
RLPCC, RLPCP
RLAPC, RLAPP
RLPCC, RLPCP
6
20
40
3
70
20
20
8
Cingular
Recommendation
1 (R10)
4 (R11)
Page 6 of 39
Parameter
Feature
Level
Class
Range
Units
Commands
QCOMPUL
REGINTUL
CELL
CELL
VARIABLE
FIXED
0 to 100
1 to 30
%
SACCH
periods
RLPCC, RLPCP 30
RLPCC, RLPCP. 5
90
1
DTXFUL
CELL
FIXED
0 to 40
SACCH
periods
RLPCC, RLPCP 5
STEPLIMDL
ALPHA
BSC
BSC
FIXED
VARIABLE
ON, OFF
0 to 10
0.1
OFF
RAEPC, RAEPP 0
OFF
0
GAMMA
GPRS/EGPRS Dynamic MS
Power Control
CELL
VARIABLE
dB
RLGSC, RLGSP 0
AMRPCSTATE
CELL
FIXED
ACTIVE or INACTIVE
RLAPI, RLAPE,
RLAPP
INACTIVE
ACTIVE
UPDWNRATIO
DBPSTATE
BSC
CELL
FIXED
FIXED
100 to 700
ACTIVE or INACTIVE
200
ACTIVE
SDCCHREG
SSDESDL
CELL
CELL
FIXED
VARIABLE
ON, OFF
47 to 110
ON
90 or 93
SSDESDLAFR
CELL
VARIABLE
47 to 110
dBm
(negative)
RLAPC, RLAPP 70
96
REGINTDL
CELL
FIXED
1 to 10
SACCH
periods
RLBCC, RLBCP 5
SSLENDL
CELL
FIXED
3 to 15
SACCH
periods
RLBCC, RLBCP 5
LCOMPDL
QDESDL
QDESDLAFR
QCOMPDL
QLENDL
CELL
CELL
CELL
CELL
CELL
VARIABLE
VARIABLE
VARIABLE
VARIABLE
FIXED
0 to 100
0 to 70
0 to 70
0 to 60
1 to 20
%
dtqu
dtqu
%
SACCH
periods
RLBCC, RLBCP
RLBCC, RLBCP
RLAPC, RLAPP
RLBCC, RLBCP
RLBCC, RLBCP
5
30 to 40
40
50 to 55
3
BSPWRMIN
DTXD
DTXU
HOP
CELL
CELL
CELL
CELL
FIXED
FIXED
FIXED
FIXED
20 to +50
ON, OFF
0 to 2
ON, OFF, TCH
dBm
RLBCC, RLBCP 20
RLCXC, RLCXP OFF
RLSSC, RLSSP
RLCHC, RLCFP OFF
HSN
FHOP
Frequency Hopping
Frequency Hopping
CELL
CELL
VARIABLE
VARIABLE
0 to 63
BB, SY
RLCHC, RLCFP
RXMOC,
RXMOP
COMB
Frequency Hopping
CELL
VARIABLE
FLT, HYB
RXMOI,
RXMOC,
RXMOP
CONFMD
Frequency Hopping
CELL
VARIABLE
RXMSC,
RXMOC,
RXMOP
MAIO
MAIO Management
CELL
VARIABLE
0 to 63 or DEFAULT
dBm
(negative)
Ericsson Default
70
20
20
30
8
Cingular
Recommendation
-20
ON
1
ON for TCH
OFF for BCCH
SY
HYB
NODEL
MINDIST
Page 7 of 39
Parameter
Feature
Level
Class
Range
IHO
TMAXIHO
TIHO
MAXIHO
QOFFSETUL
Intra-Cell Handover
Intra-Cell Handover
Intra-Cell Handover
Intra-Cell Handover
Intra-Cell Handover
CELL
CELL
CELL
CELL
CELL
FIXED
FIXED
FIXED
VARIABLE
VARIABLE
ON, OFF
0 to 60
0 to 60
0 to 15
50 to +50
QOFFSETULAFR
Intra-Cell Handover
CELL
VARIABLE
QOFFSETDL
Intra-Cell Handover
CELL
QOFFSETDLAFR
Intra-Cell Handover
SSOFFSETUL
SSOFFSETULAFR
SSOFFSETDL
SSOFFSETDLAFR
ASSOC
IBHOASS
AW
CAND
AWOFFSET
SCLDTIMEINT
Units
Commands
Ericsson Default
Cingular
Recommendation
dtqu
RLIHC, RLIHP
RLIHC, RLIHP
RLIHC, RLIHP
RLIHC, RLIHP
RLIHC, RLIHP
OFF
6
10
3
0
ON
6
10
1
-5 for hopping
-14 for fixed
50 to +50
dtqu
RLIHC, RLIHP
5 for hopping
0 for fixed
VARIABLE
50 to +50
dtqu
RLIHC, RLIHP
-5 for hopping
-14 for fixed
CELL
VARIABLE
50 to +50
dtqu
RLIHC, RLIHP
5 for hopping
0 for fixed
Intra-Cell Handover
Intra-Cell Handover
Intra-Cell Handover
Intra-Cell Handover
Assignment to Other Cell
Assignment to Other Cell
Assignment to Other Cell
Assignment to Other Cell
Assignment to Other Cell
Overlaid / Underlaid Subcells /
Subcell Load Distribution
CELL
CELL
CELL
CELL
BSC
BSC
CELL
CELL
CELL
BSC
VARIABLE
VARIABLE
VARIABLE
VARIABLE
FIXED
FIXED
FIXED
FIXED
VARIABLE
VARIABLE
30 to +30
30 to +30
30 to +30
30 to +30
ON, OFF
ON, OFF
ON, OFF
AWN, NHN, BOTH
0 to 63
100 to 1000
dB
dB
dB
dB
RLIHC, RLIHP
RLIHC, RLIHP
RLIHC, RLIHP
RLIHC, RLIHP
RLLBC, RLLBP
RLLBC, RLLBP
RLLOC, RLLOP
RLNRC, RLNRP
RLNRC, RLNRP
RAEPC, RAEPP
0
0
0
0
OFF
OFF
OFF
BOTH
3
100
24
24
16
16
ON
ON
ON
BOTH
5
100
SCLD
CELL
FIXED
ON, OFF
RLLLC, RLLLP
OFF
SCLDLL
CELL
VARIABLE
0 to 99
RLLLC, RLLLP
20
20
SCLDUL
CELL
VARIABLE
0 to 100
RLLLC, RLLLP
30
30
LOL
CELL
VARIABLE
0 to 200
dB
RLOLC, RLOLP
200
LOLHYST
CELL
VARIABLE
0 to 63
dB
RLOLC, RLOLP 3
TAOL
CELL
VARIABLE
0 to 61
Bit periods
RLOLC, RLOLP
61
TAOLHYST
CELL
VARIABLE
0 to 61
Bit periods
RLOLC, RLOLP
HCSBANDHYST
THO
NHO
HCSBAND
HCSBANDTHR
BSC
BSC
BSC
BSC
BSC
VARIABLE
FIXED
FIXED
VARIABLE
FIXED
0 to 63
10 to 100
2 to 10
1 to 8
0 to 150
dB
s
RLHBC, RLHBP
RLLBC, RLLBP
RLLBC, RLLBP
RLHBC, RLHBP
RLHBC, RLHBP
s
s
dB
ms
dBm
(negative)
2
30
3
95
2
30
3
2
2
Page 8 of 39
Parameter
Feature
Level
Class
Range
Units
Commands
Ericsson Default
Cingular
Recommendation
LAYER
CELL
FIXED
1 to 8
RLLHC, RLLHP
2 (GSM1900)
3 (GSM800)
LAYERTHR
CELL
FIXED
0 to 150
dBm
(negative)
RLLHC, RLLHP
75
95 (GSM1900)
85 (GSM800)
LAYERHYST
PSSTEMP
PTIMTEMP
FASTMSREG
XRANGE
MBCCHNO
CELL
CELL
CELL
CELL
CELL
CELL
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
0 to 63
0 to 63
0 to 600
ON, OFF
YES, NO
128 to 251 (GSM 800)
512 to 810 (GSM 1900)
dB
dB
s
RLLHC, RLLHP
RLLHC, RLLHP
RLLHC, RLLHP
RLLHC, RLLHP
RLDEC, RLDEP
RLMFC, RLMFP
2
0
0
OFF
NO
3
0
0
OFF
NO
ICMSTATE
CELL
FIXED
RLIMI, RLIMP ,
RLIME
PASSIVE
ACTIVE
INTAVE
CELL
FIXED
1 to 31
RLIMC, RLIMP
25
LSSTATE
BSC
FIXED
ACTIVE, INACTIVE
RLLSI, RLLSE,
RLLSP
INACTIVE
INACTIVE
CLSTIMEINTERVAL
CLSSTATE
BSC
CELL
VARIABLE
FIXED
100 to 1000
ACTIVE, INACTIVE
ms
100
INACTIVE
CLSACC
CLSLEVEL
CLSRAMP
HOCLSACC
RHYST
CLMRKMSG
MODE
CELL
CELL
CELL
CELL
CELL
BSC
BSC
VARIABLE
VARIABLE
FIXED
VARIABLE
VARIABLE
FIXED
FIXED
1 to 100
0 to 99
0 to 30
ON, OFF
0 to 100
0 to 3
MULTI, SINGLE
%
%
s
RLLCC, RLLCP
RLLCC, RLLCP
RLLCC, RLLCP
RLLCC, RLLCP
RLLCC, RLLCP
RAEPC, RAEPP
RLOMC,
RLOMP
40
20
16
ON
75
0
Single or Multi
GSYSTYPE
Multiband Operation
BSC
FIXED
RLTYC, RLTYI,
RLTYP
CSYSTYPE
Multiband Operation
CELL
FIXED
RLDEI, RLDEP
MBCR
DCAHANDOVER
DCASTATE
Multiband Operation
Differential Channel Allocation
Differential Channel Allocation
CELL
BSC
BSC
FIXED
FIXED
0 to 3
0, 1
ON, OFF
RLSSC, RLSSP 0
RAEPC, RAEPP 0
RLDCI, RLDCE , OFF
RLDCP
EMERGPRL
STATSINT
BSC
BSC
FIXED
FIXED
1 to 15
1 to 96
CHTYPE
CHRATE
PHSTATE
CELL
CELL
BSC
TCH, SDCCH
FR, HR
0,1
ARFCN
SACCH
periods
15 min.
periods
40
20
5
OFF
75
0
SINGLE
Mixed or GSM1900
GSM800 or GSM1900
GSM800 or GSM1900
0, 2 or 3
0
OFF
RLDCI , RLDCP
RLSCI, RLSCP
RLPRC, RLPRP
RLPRC, RLPRP
RAEPC, RAEPP 0
Page 9 of 39
Parameter
Feature
Level
Class
Range
Units
Commands
Ericsson Default
Cingular
Recommendation
ACSTATE
Adaptive Configuration of
Logical Channels
CELL
FIXED
ON, OFF
RLACI, RLACE,
RLACP
OFF
ON
SLEVEL
Adaptive Configuration of
Logical Channels
CELL
FIXED
0 to 2, CONG
RLACC, RLACP 0
STIME
Adaptive Configuration of
Logical Channels
CELL
FIXED
15 to 360
RLACC, RLACP 20
40
COEXUMTS
BSC
0, 1
RAEPC, RAEPP 0
0, 1
COEXUMTSINT
BSC
100 to 1000
1000
UMFI
CELL
MFDDARFCN: 0 to 16383
MSCRCODE: 0 to 511
DIVERSITY: DIV or NODIV
FDDQMIN
CELL
0 to 7
dB (relative
to -20)
RLSUC, RLSUP 0
FDDQOFF
CELL
0 to 15
dB
RLSUC, RLSUP 8
SPRIO
CELL
NO, YES
RLSUC, RLSUP NO
YES
QSI
CELL
0 to 15
4 dB from
-98dBm
RLSUC, RLSUP 15
ISHOLEV
CELL
0 to 99
RLLOC, RLLOP 20
99
FDDMRR
CELL
0 to 3
RLSUC, RLSUP 0
QSC
CELL
0 to 15
RLSUC, RLSUP 15
15
QSCI
CELL
0, 1
RLSUC, RLSUP 0
CELLR
CELL
RLNRI, RLNRE,
RLNRP, RLNCP
SET
MODE
Adaptive Multi-Rate
Adaptive Multi-Rate
BSC
BSC
FIXED
FIXED
RLADC, RLADP
RLADC, RLADP
HYST
THR
AMRFRSUPPORT
AMRHRSUPPORT
LQCACT
Adaptive Multi-Rate
Adaptive Multi-Rate
Adaptive Multi-Rate
Adaptive Multi-Rate
Link Quality Control in EGPRS
BSC
BSC
BSC
BSC
BSC
FIXED
FIXED
FIXED
FIXED
FIXED
0 to 15
0 to 63
0 to 4
0 to 4
0, 1
ms
RLUMC,
RLUMP
4 dB from
-98dBm
0.5 dB
0.5 dB
RLADC, RLADP
RLADC, RLADP
RAEPC, RAEPP 0
RAEPC, RAEPP 0
RAEPC, RAEPP 0
1
1
3
Page 10 of 39
Parameter
Feature
Level
Class
Range
LQCIR
LQCDEFAULTMCSDL
LQCDEFAULTMCSUL
LQCHIGHMCS
LQCUNACK
LA
CHCSDL
PCUQOS
BSC
BSC
BSC
BSC
BSC
CELL
CELL
BSC
FIXED
FIXED
FIXED
FIXED
FIXED
VARIABLE
VARIABLE
FIXED
THPMBRFACTOR
QOSTHP1
Units
Commands
Ericsson Default
Cingular
Recommendation
0, 1
MCS-1to MCS-9
MCS-1to MCS-9
MCS-1to MCS-9
0 to 2
ON, OFF
NA, CS-1 to CS-4
0, 1
RAEPC, RAEPP
RAEPC, RAEPP
RAEPC, RAEPP
RAEPC, RAEPP
RAEPC, RAEPP
RLGSC, RLGSP
RLGSC, RLGSP
RAEPC, RAEPP
1
MCS-5
MCS-5
MCS-9
1
ON
CS-2
0
1
5
3
9
1
OFF
CS-2
0
FIXED
0 to 10
RAEPC, RAEPP 0
FIXED
1 to 10
RAEPC, RAEPP 3
QOSTHP2
FIXED
1 to 10
RAEPC, RAEPP 2
CONVSTREAMTHP
FIXED
1 to 3
RAEPC, RAEPP 1
GPRSQOS
GPRS/EGPRS Channel
Administration
BSC
FIXED
0 to 1
DBTSP
0 - Legacy Orange
BSCs
1 - Legacy Blue BSCs
IRC
Interference Rejection
Combining
CELL
FIXED
ON, OFF
ON
FBOFFS
BAND
CELL
CELL
VARIABLE
FIXED
-40 to 40
GSM800, GSM900, GSM1800, GSM1900
dB
RLLOC, RLLOP 0
RLDGI , RLDGP
-10
GSM800 or GSM1900
DLDELAY
GPRS/EGPRS Connection
Control And Transfer
BSC
FIXED
0 to 5000
ms
1000
ESDELAY
GPRS/EGPRS Connection
Control And Transfer
BSC
FIXED
0 to 2000
ms
500
TFILIMIT
GPRS/EGPRS Connection
Control And Transfer
BSC
FIXED
0 to 31
RAEPC, RAEPP 4
ULDELAY
GPRS/EGPRS Connection
Control And Transfer
BSC
FIXED
1000
2000
USFLIMIT
GPRS/EGPRS Connection
Control And Transfer
BSC
FIXED
0 to 6
RAEPC, RAEPP 2
DHA
DMQB
CELL
CELL
FIXED
FIXED
ON, OFF
ON, OFF
ON
ON
DMQBAMR
CELL
VARIABLE
0 to 100
RLDMC,
RLDMP
50
50
DMQG
CELL
FIXED
ON, OFF
RLDMC,
RLDMP
OFF
ON
DMQGAMR
CELL
VARIABLE
0 to 100
RLDMC,
RLDMP
35
30
dtqu
dtqu
Page 11 of 39
Parameter
Feature
Level
Class
Range
DMSUPP
CELL
FIXED
ON, OFF
DMTHAMR
CELL
VARIABLE
0 to 100
DTHAMR
CELL
VARIABLE
ABISALLOC
ALLOCPREF
ANT
ANTA
ANTB
BTDM
CBCHD
CRT
CTEI
DMQBNAMR
DMQGNAMR
DMTHNAMR
Flexible Abis
DTM
Hardware
Hardware
Hardware
GPRS
GPRS
Ericsson MSC
Hardware
AMR
AMR
AMR
CELL
CELL
CELL
CELL
CELL
BSC
CELL
BSC
CELL
CELL
CELL
CELL
VARIABLE
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
Fixed, Flexible
QUAL, PACK
1-7 Character
1-7 Character
1-7 Character
6 to 1530 in steps of 6, OFF
Yes, No
RCR-SCRT
58 to 62
0 to 100
0 to 100
0 to 100
DTCB
CELL
VARIABLE
-63 to 63
DTCBHYST
CELL
VARIABLE
0 to 63
DTCBSC
DTHNAMR
EGPRSBPCLIMIT
BSC
CELL
BSC
VARIABLE
FIXED
FIXED
0,1
0 to 100
0-8160
0
20
0
0
2048
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
CELL
CELL
CELL
CELL
CELL
CELL
VARIABLE
VARIABLE
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
0-2 2
0-1
0 to 255
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 to 2500
0 or 1
0 to 59
1 to 60
2 to 61
3 to 62
ACTIVE, IDLE, Omitted
5 to 12
2
0
2
0
FBCHALLOC
FLEX64KGPRS
GTDM
HNDBEFOREBANSWM
HNDRELCHINTRAM
HNDSDCCHINTI
HNDSDCCHINTOM
HNDSDCCHM
HNDSDCCHTCHM
HNDTGSOPINTRA
LATAUSED
LIMIT1
LIMIT2
LIMIT3
LIMIT4
LISTTYPE
MAXLAPDM
Channel administration /
Immediate assignment on TCH
Flexible Abis
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Idle Channel Measurements
Idle Channel Measurements
Idle Channel Measurements
Idle Channel Measurements
Neighbor
DTM
Units
Commands
Ericsson Default
Cingular
Recommendation
RLDMC,
RLDMP
OFF
ON only in good
environment.
RLDMC,
RLDMP
20
start at 20
conservative.
RLDHC, RLDHP 20
start at 20
conservative.
Fixed
QUAL
Fixed
QUAL
OFF
No
120
NO
45
30
20
100
0
0
-63
Rxlev
Rxlev
Rxlev
Rxlev
1
1
1
1
1
1
80
0
2
6
12
22
RLIMC, RLIMP
RLIMC, RLIMP
RLIMC, RLIMP
RLIMC, RLIMP
1
1
1
1
1
1
80
0
1
3
6
12
Page 12 of 39
Parameter
Feature
Level
Class
Range
MAXNOSDCCHTRX
MAXSBLK
MAXSMSG
MBCRAC
MCCSUPPORT
MPDCH
MPWR
MSQUEUING
Channel administration /
Immediate assignment on TCH
GPRS
GPRS
GPRS
other
GPRS
Hardware
Wireless Priority Queing
BSC
CELL
CELL
BSC
BSC
CELL
CELL
BSC
VARIABLE
FIXED
FIXED
FIXED
FIXED
FIXED
VARIABLE
FIXED
1 to 4
1 to 4
1 to 16
0-1
0-2
Yes, No
0 to 63
0-1
NDIST
CELL
VARIABLE
NNCELLS
PAGLATA
PAGNUMBERLA
PAGREP1LA
PAGREPCT1LA
PAGREPGLOB
PAGTIMEFRST1LA
PAGTIMEFRSTGLOB
PAGTIMEREP1LA
PAGTIMEREPGLOB
PAGTIMEREPLATA
PDCHPREEMPT
PILTIMERFLEX
PRACHBLK
PRIMPLIM
PSCVL
QLENGTH
QOSMAPPING
RESLIMIT
ROMTBIPADDRLSW
ROMTBIPADDRMSW
RXD
SECPAGEPATH
SPDCH
SYNCSRC
SYSTYPE
TEI
TFMODE
TIMHNDCMDINTRAM
TIMPAGINGM
TRAFBLK
TRXC
TXID
CELL
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
CELL
BSC
CELL
CELL
BSC
CELL
BSC
CELL
BSC
BSC
CELL
BSC
CELL
BOTH
CELL
CELL
CELL
BSC
BSC
CELL
CELL
CELL
VARIABLE
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
VARIABLE
VARIABLE
VARIABLE
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
Units
Commands
Ericsson Default
Cingular
Recommendation
1
2
7
0
0
No
1
2
7
0
1
No
0 to 63
10
10
1 to 5
0 or 1
1 to3
0 to 3
0 to 3
0 or 1
2 to 10
2 to 10
2 to 10
2 to 10
2 to 10
0-4
0-100
1 to 12
1 to 8
FRV1, FRV2, FRV3, HRV1, HRV2, HRV3
0 to 32
0 to 2
1 to 100
0-65535
0-65535
A, B, AB
0 to 2
0 to 16
INTI, INTE, PCM, DEFAULT
GSM1900/GSM850
0 to 63 for G12, 0 to 57 for G01
M, S, SA
5 to 120
2 to 20
0 to 10
0 to 15
0 to 15
3
0
1
2
2
0
4
4
7
7
7
0
50
4
8
3
0
1
2
2
0
4
4
7
7
7
4
50
4
8
5
0
25
0
0
5
2
25
0
0
AB
1
0
DEFAULT
GSM1900
1
0
C
*
5
9
0
5
9
0
Page 13 of 39
Parameter
Comments
DL
UL
BSPWRB
CELL
RSITE
TG
CGI
MCC
MNC
LAC
CI
NCC
BCC
BCCHNO
BCCHTYPE
Whether BCCH is combined with SDCCH/4, not combined with SDCCH/4, or combined with SDCCH/4+CBCH.
AGBLK
No. CCCH blocks reserved for access grants, 1 if Sys info 7 & 8 or CBCH used with non combined SDCCH (i.e. BCCHTYPE = NCOMB, SDCCH = 1 or more and CBCH = YES) AGBLK = 0 if
BCCHTYPE = COMB
MFRMS
FNOFFSET
ECSC
SCTYPE
MNCDIGITHAND
TSC
MSTXPWR
Indicates whether MS in the cell is allowed to use early class mark sending
Subcell type. S-BCCH cell type - UL for 850MHz and OL for 1900MHz
0: 2-digit MNC sent. 1: 3-digit MNC sent on A-interface and 2-digit on Um. 2: 3-digit MNC sent
Training Sequence Code.
Maximum MS power while maintaining a TCH connection
BSPWRT
CHGR
STATE
NUMREQBPC
SYSDEF should only be used for cells with a single CHGR. If more than 1 CHGR is setup then NUMREQBPC should be set to 8 times the number of TRX required in the CHGR.
Page 14 of 39
Parameter
Comments
DCHNO
BCCD
Defines if the channel group frequencies are allowed for Immediate Assignment.
SDCCH
CCHPOS
TN
CBCH
TRADROPLEVEL
Flag for whether Cell Broadcast Channel is defined. Set to NO when BCCHTYPE COMBC is used
Transcoder threshold for high dropped call rate
TRADROPNOTRAF
CELLR
CTYPE
RELATION
CS
ACCMIN
CCHPWR
CRH
NCCPERM
SIMSG
MSGDIST
CB
CBQ
Page 15 of 39
Parameter
Comments
ACC
MAXRET
TX
ATT
T3212
CRO
TO
PT
FASTASSIGN
NOOFPHYSINFOMSG
TIMER3105
EVALTYPE
TINIT
TALLOC
TURGEN
TAAVELEN
SSEVALSD
QEVALSD
SSEVALSI
QEVALSI
SSLENSD
QLENSD
SSLENSI
QLENSI
SSRAMPSD
SSRAMPSI
Time to ramp up N-cell measurements on SDCCH STATE ACTIVE or HALTED C F Cell or Channel Group state.
MISSNM
BSPWR
MSRXMIN
BSRXMIN
Page 16 of 39
Parameter
Comments
MSRXSUFF
BSRXSUFF
BSTXPWR
KHYST
LHYST
TRHYST
KOFFSET
LOFFSET
TROFFSET
HIHYST
LOHYST
HYSTSEP
OFFSET
BADQDL
BADQUL
LOWSSDL
SS offset
DL BQ limit used for urgency counter - not used in HO algorithm
UL BQ limit used for urgency counter - not used in HO algorithm
DL low SS limit used for counter - not used in HO algorithm
LOWSSUL
TALIM
PSSBQ
PSSTA
PTIMBQ
PTIMTA
BQOFFSET
BQOFFSETAFR
EXTPEN
QLIMDL
QLIMDLAFR
RxQual threshold at MS for h/o. Lower threshold used for cells hopping over 6 or more frequencies, 55 if cell is not hopping *QLIMUL 0-100 55 45 C V RxQual threshold at BTS for h/o. Lower
threshold used for cells hopping over 6 or more frequencies, 55 if cell is hopping
QLIMUL
QLIMULAFR
RxQual threshold at BTS for h/o. Lower threshold used for cells hopping over 6 or more frequencies, 55 if cell is not hopping.
PSSHF
PTIMHF
IBHOSICH
IHOSICH
SCHO
CELLQ
Page 17 of 39
Parameter
Comments
MAXTA
Maximum timing advance permitted before disconnection. Normal cell can work to 63. RBS200 Xrange cell with SPP cards can work to 133 and new RBS2000 Xtended range hardware can work
to 219.
RLINKUP
RLINKT
HPBSTATE
CHALLOC
2: Non hopping TCH on BCCH is allocated as last preference 1: Non-hopping TCH on BCCH allocated as first preference 0: No preference
EBANDINCLUDED
Decide whether channels in the P-GSM 900 band only or whether also GSM 900 G1 channels are to be considered for handling of the radio features.
MAXCHDATARATE
Defines the maximum channel data rate allowed in the BSC - modem type.
SPEECHVERUSED
Decides if the used speech version shall be placed at the top in the list of allowed speech version at handover.
BSCMC
Identifies if more than one full rate TCH are allowed to be allocated for each MS connection in BSC internal cells.
CMDR
CHAP
SAS
NECI
0 = GSM est. causes only, 1 = phase 2 est. causes NEWNAME 1 TO 7 CHAR. EXCEPT ALL * * C F The parameter is used to change the name of a cell.
MC
CHCODING
GPRSNWMODE
GPRSPRIO
Sets the priority between PDCHs and the features Dynamic Half Rate Allocation/Half Rate Packing, Cell Load Sharing and Sub cell Load Distribution
PILTIMER
Time a dynamic PDCH channel can remain idle before being reconfigured to a TCH, EDGE\GPRS Cell = 10.
EGPRSBPCLIMIT
ONDEMANDGPHDEV
Number of reserved GPH devices in an RPP that can be used for on-demand PDCH only.
Page 18 of 39
Parameter
Comments
TBFDLLIMIT
The number of simultaneous TBFs for each PDCH is used as TBF downlink limit.
TBFULLIMIT
The number of simultaneous TBFs for each PDCH is used as TBF uplink limit. TDD 1 to 255, OFF OFF B F Ericsson MSC Parameter Only
NACCACT
PDCHPREEMPT
Defines what kind of on-demand PDCHs are possible to pre-empt for the CS traffic:
GPRSSUP
FPDCH
SCALLOC
Restrict EGPRS/GPRS to a certain subcell when a subcell exists. Set per Dedicated PDCH location.
PDCHALLOC
PSKONBCCH
NUMREQCS3CS4BPC
NUMREQEGPRSBPC
Minimum number of required EGPRS BPCs (set per CHGR). CHGR0 = 4, CHGR1 or greater = 0.
TN7BCCH
GPRSEDAACT
PULSCHEDINT
DMPSTATE
AMRPCSTATE
SSDESUL
SSDESULAFR
SSLENUL
LCOMPUL
QDESUL
QDESULAFR
QLENUL
Page 19 of 39
Parameter
Comments
QCOMPUL
REGINTUL
DTXFUL
STEPLIMDL
ALPHA
GAMMA
Gives target value for the received signal at the BTS (PS Specific).
AMRPCSTATE
UPDWNRATIO
DBPSTATE
SDCCHREG
SSDESDL
SSDESDLAFR
REGINTDL
SSLENDL
LCOMPDL
QDESDL
QDESDLAFR
QCOMPDL
QLENDL
BSPWRMIN
DTXD
DTXU
HOP
HSN
FHOP
COMB
CONFMD
MAIO
Page 20 of 39
Parameter
Comments
IHO
TMAXIHO
TIHO
MAXIHO
QOFFSETUL
QOFFSETULAFR
QOFFSETDL
Offset FQSS function along RxQual axis (downlink) ; -5 Hopping Layer, -14 BCCH Layer
QOFFSETDLAFR
SSOFFSETUL
SSOFFSETULAFR
SSOFFSETDL
SSOFFSETDLAFR
ASSOC
IBHOASS
AW
CAND
AWOFFSET
SCLDTIMEINT
SCLD
SCLDLL
SCLDUL
LOL
Path loss threshold. S-BCCH cell type = (EIRP+85), if data on BCCH set to LOL=0.
LOLHYST
TAOL
TAOLHYST
HCSBANDHYST
THO
NHO
HCSBAND
HCSBANDTHR
Page 21 of 39
Parameter
Comments
LAYER
LAYERTHR
Signal level threshold applying to that cell. (D-BCCH cell: 85 - 1900MHz, 95 - 850MHz)
LAYERHYST
PSSTEMP
PTIMTEMP
FASTMSREG
XRANGE
MBCCHNO
ICMSTATE
INTAVE
LSSTATE
CLSTIMEINTERVAL
CLSSTATE
CLSACC
CLSLEVEL
CLSRAMP
HOCLSACC
RHYST
CLMRKMSG
MODE
% idle channel free level, below which no shredded call is accepted by target cell
% idle channel free level at which shedding of calls is started
Time interval in which hysteresis is ramped down
Enable/disable acceptance of incoming h/o due to Load Sharing
Hysteresis reduction factor (how much of hysteresis zone is used for call shedding)
Indicates how the Classmark Change message will be handled if it is received as a first RR message from the Mobile Station
The BSC band operation mode identifier.
GSYSTYPE
Specifies the system type for the BSC. Mixed allows both 850MHz and 1900MHz within the same BSC.
CSYSTYPE
MBCR
DCAHANDOVER
DCASTATE
No. of n-cells from each band reported in measurement report: different between dual band and single band markets.
Differential Channel Allocation is not used
Differential channel allocation switch.
EMERGPRL
STATSINT
CHTYPE
CHRATE
PHSTATE
Page 22 of 39
Parameter
Comments
ACSTATE
SLEVEL
Remaining SDCCH sub channels when attempt to increase number will take place
STIME
COEXUMTS
Support for Coexistence of GSM and UMTS
COEXUMTSINT
Time interval between traffic load checking.
UMFI
UTRAN Measurement Frequency Information for cell reselection in GSM Idle Mode and GPRS/EGPRS Ready and Standby states
FDDQMIN
Defines the minimum threshold for the "quality" measure Ec/No for cell reselection to UTRAN cells.
FDDQOFF
Defines the inter-system cell reselection offset to UTRAN cells.
SPRIO
Indicates if 3G cells may be searched when BSIC decoding is required.
QSI
Indicates the threshold to start UTRAN FDD measurements in Idle mode and Stand-by and Ready states.
ISHOLEV
Inter system handover evaluations start. % of TCH idle.
FDDMRR
Defines how many measured neighbouring UTRAN cells should be included in measurement reports
QSC
Indicates the threshold to start UTRAN FDD measurements in Active mode. 15 = Never
QSCI
UTRAN measurements after entering active mode, before reading the first QSC. 0 = Use QSI threshold, 1 = always.
CELLR
SET
MODE
HYST
THR
AMRFRSUPPORT
AMRHRSUPPORT
LQCACT
Page 23 of 39
Parameter
Comments
LQCIR
LQCDEFAULTMCSDL
LQCDEFAULTMCSUL
LQCHIGHMCS
LQCUNACK
LA
CHCSDL
PCUQOS
Used to control which mode LQC shall run TBFs using RLC acknowledged mode.
Controls which DL MCS is used when LQC is switched OFF.
Used to control the MCS for uplink transfers
Used to define the highest allowed MCS level to be used
Used to shift the selection of MCS to a more robust MCS level when RLC unacknowledged mode is used.
Used to switch GPRS Link Adaptation ON and OFF
If GPRS Link Adaptation is switched on, then used as initial coding scheme for downlink
Activates or deactivates support for 3GPP TS 08.18 Packet Flow Management (PFM) in the PCU.
THPMBRFACTOR
To what degree should MBR be taken into account for scheduling interactive user.
QOSTHP1
QOSTHP2
CONVSTREAMTHP
Defines which THP to use if the requested traffic class is not available.
GPRSQOS
IRC
FBOFFS
BAND
Offset between BCCH frequency band group and non- BCCH frequency band group.
Frequency band supported by the transmitter/receiver
DLDELAY
Defines the time a downlink TBF is kept alive after there is no more user data to send in downlink.
ESDELAY
Defines the time a downlink TBF is kept alive after it has been automatically set up by the initiation of an uplink TBF.
TFILIMIT
Defines the minimum number of TFIs available for a PSET before ESDELAY or DLDELAY will initiate.
ULDELAY
USFLIMIT
Specifies the lower limit for available USFs before uplink TBF is released.
DHA
DMQB
DMQBAMR
DMQG
Defines whether or not Dynamic AMR Full Rate (FR) to AMR Half Rate (HR) Mode Adaptation quality evaluation is active.
DMQGAMR
Page 24 of 39
Parameter
Comments
DMSUPP
DMTHAMR
DTHAMR
ABISALLOC
ALLOCPREF
ANT
ANTA
ANTB
BTDM
CBCHD
CRT
CTEI
DMQBNAMR
DMQGNAMR
DMTHNAMR
Controls the way Abis paths are allocated to the TCHs capable of 64kbps, set per TG.
DTM connection shall be allocated with maximum speech quality considerations or with packing considerations prefer TCH/HR.
Name of antenna connected to transmitter
Name of antenna A connected to receiver
Name of antenna B connected to receiver
Base time duration of implicit detach of a mobile subscriber by the network, Ericsson MSC Only.
Shall PSI8 be transferred on the PBCCH or not.
Channel Rate and Type, Ericsson MSC Only.
TGC
Non-AMR trigger from HR to FR channel
Non-AMR trigger from FR to HR channel
HR Packing for Non-AMR Dual Rate capable MS units
DTCB
Distance to cell border threshold between active channel and neighboring BCCHs.
DTCBHYST
DTCBSC
DTHNAMR
EGPRSBPCLIMIT
Defines if the DTCB criterion is taken into consideration during subcell changes (1), or not (0)
HR Packing at initial call set-up for Non-AMR Dual Rate capable MS units.
Maximum allowed number of EGPRS timeslots or data connections in the BSC.
FBCHALLOC
FLEX64KGPRS
GTDM
HNDBEFOREBANSWM
HNDRELCHINTRAM
HNDSDCCHINTI
HNDSDCCHINTOM
HNDSDCCHM
HNDSDCCHTCHM
HNDTGSOPINTRA
LATAUSED
LIMIT1
LIMIT2
LIMIT3
LIMIT4
LISTTYPE
MAXLAPDM
0 - No selection preference; 1 - Select channels in BCCH frequency band first; 2 - Select channels in BCCH frequency band last. (Tri-Band Usage Only)
Abis resource allocation handling for EGPRS capable channel.
Guard time duration, Ericsson MSC Only.
Indicates if an inter-MSC handover is allowed on traffic channels before answer from B-subscriber, Ericsson MSC Only.
Defines the release of the original channel after expiration of the timer TIMHNDCMDINTRAM for handover time supervision in intra-MSC inter-BSC handover, Ericsson MSC Only.
Incoming inter-MSC handover on signaling channels in non-anchor MSC, Ericsson MSC Only.
Determines if outgoing inter-MSC handover is allowed on signaling channels in anchor MSC, Ericsson MSC Only.
Determines if intra-MSC inter-BSC handover is allowed on signaling channels, Ericsson MSC Only.
If intra-MSC inter-BSC handover is allowed from signaling to traffic channel, Ericsson MSC Only.
Time supervision of switching moment of the group switch (GS) in the MSC at intra-MSC inter-BSC handover.Ericsson MSCOnly
Defines the usage of LATA administration, Ericsson MSC Only.
Boundary between interference bands 1&2, Alt. Settings: 3 for macro-cells. 6 for micro cells
Boundary between interference bands 2&3, Alt. Settings: 5 for macro cells, 10 for micro cells
Boundary between interference bands 3&4, Alt. Settings: 8 for macro sells, 14 fro micro cells
Boundary between interference bands 4&5, Alt. Settings: 10 for macro cells, 18 for micro cells
This parameter identifies which type of list the chosen frequencies will be on.
DTM, to control the maximum length of the GPRS signaling messages sent on the FACCH.
Page 25 of 39
Parameter
Comments
MAXNOSDCCHTRX
MAXSBLK
MAXSMSG
MBCRAC
MCCSUPPORT
MPDCH
MPWR
MSQUEUING
NDIST
NNCELLS
PAGLATA
PAGNUMBERLA
PAGREP1LA
PAGREPCT1LA
PAGREPGLOB
PAGTIMEFRST1LA
PAGTIMEFRSTGLOB
PAGTIMEREP1LA
PAGTIMEREPGLOB
PAGTIMEREPLATA
PDCHPREEMPT
PILTIMERFLEX
PRACHBLK
PRIMPLIM
PSCVL
QLENGTH
QOSMAPPING
RESLIMIT
ROMTBIPADDRLSW
ROMTBIPADDRMSW
RXD
SECPAGEPATH
SPDCH
SYNCSRC
SYSTYPE
TEI
TFMODE
TIMHNDCMDINTRAM
TIMPAGINGM
TRAFBLK
TRXC
TXID
Page 26 of 39
Parameter
DL
UL
BSPWRB
CELL
RSITE
TG
CGI
MCC
MNC
LAC
CI
NCC
BCC
BCCHNO
BCCHTYPE
AGBLK
MFRMS
FNOFFSET
ECSC
SCTYPE
MNCDIGITHAND
TSC
MSTXPWR
BSPWRT
CHGR
STATE
NUMREQBPC
Page 27 of 39
Parameter
DCHNO
BCCD
SDCCH
CCHPOS
TN
CBCH
TRADROPLEVEL
TRADROPNOTRAF
CELLR
CTYPE
RELATION
CS
ACCMIN
CCHPWR
CRH
NCCPERM
SIMSG
MSGDIST
CB
CBQ
Page 28 of 39
Parameter
ACC
MAXRET
TX
ATT
T3212
CRO
TO
PT
FASTASSIGN
NOOFPHYSINFOMSG
TIMER3105
EVALTYPE
TINIT
TALLOC
TURGEN
TAAVELEN
SSEVALSD
QEVALSD
SSEVALSI
QEVALSI
SSLENSD
QLENSD
SSLENSI
QLENSI
SSRAMPSD
SSRAMPSI
MISSNM
BSPWR
MSRXMIN
BSRXMIN
Page 29 of 39
Parameter
MSRXSUFF
BSRXSUFF
BSTXPWR
KHYST
LHYST
TRHYST
KOFFSET
LOFFSET
TROFFSET
HIHYST
LOHYST
HYSTSEP
OFFSET
BADQDL
BADQUL
LOWSSDL
LOWSSUL
TALIM
PSSBQ
PSSTA
PTIMBQ
PTIMTA
BQOFFSET
BQOFFSETAFR
EXTPEN
QLIMDL
QLIMDLAFR
QLIMUL
QLIMULAFR
PSSHF
PTIMHF
IBHOSICH
IHOSICH
SCHO
CELLQ
Page 30 of 39
Parameter
MAXTA
RLINKUP
RLINKT
HPBSTATE
CHALLOC
EBANDINCLUDED
MAXCHDATARATE
SPEECHVERUSED
BSCMC
CMDR
CHAP
SAS
NECI
MC
CHCODING
GPRSNWMODE
GPRSPRIO
PILTIMER
EGPRSBPCLIMIT
ONDEMANDGPHDEV
ONDEMANDGPHDV64
PSETCHKPERIOD
Page 31 of 39
Parameter
TBFDLLIMIT
TBFULLIMIT
NACCACT
PDCHPREEMPT
GPRSSUP
FPDCH
SCALLOC
PDCHALLOC
PSKONBCCH
NUMREQCS3CS4BPC
NUMREQEGPRSBPC
TN7BCCH
GPRSEDAACT
PULSCHEDINT
DMPSTATE
AMRPCSTATE
SSDESUL
SSDESULAFR
SSLENUL
LCOMPUL
QDESUL
QDESULAFR
QLENUL
Page 32 of 39
Parameter
QCOMPUL
REGINTUL
DTXFUL
STEPLIMDL
ALPHA
GAMMA
AMRPCSTATE
UPDWNRATIO
DBPSTATE
SDCCHREG
SSDESDL
SSDESDLAFR
REGINTDL
SSLENDL
LCOMPDL
QDESDL
QDESDLAFR
QCOMPDL
QLENDL
BSPWRMIN
DTXD
DTXU
HOP
HSN
FHOP
COMB
CONFMD
MAIO
Page 33 of 39
Parameter
IHO
TMAXIHO
TIHO
MAXIHO
QOFFSETUL
QOFFSETULAFR
QOFFSETDL
QOFFSETDLAFR
SSOFFSETUL
SSOFFSETULAFR
SSOFFSETDL
SSOFFSETDLAFR
ASSOC
IBHOASS
AW
CAND
AWOFFSET
SCLDTIMEINT
SCLD
SCLDLL
SCLDUL
LOL
LOLHYST
TAOL
TAOLHYST
HCSBANDHYST
THO
NHO
HCSBAND
HCSBANDTHR
Page 34 of 39
Parameter
LAYER
LAYERTHR
LAYERHYST
PSSTEMP
PTIMTEMP
FASTMSREG
XRANGE
MBCCHNO
ICMSTATE
INTAVE
LSSTATE
CLSTIMEINTERVAL
CLSSTATE
CLSACC
CLSLEVEL
CLSRAMP
HOCLSACC
RHYST
CLMRKMSG
MODE
GSYSTYPE
CSYSTYPE
MBCR
DCAHANDOVER
DCASTATE
EMERGPRL
STATSINT
CHTYPE
CHRATE
PHSTATE
Page 35 of 39
Parameter
ACSTATE
SLEVEL
STIME
COEXUMTS
COEXUMTSINT
UMFI
FDDQMIN
FDDQOFF
SPRIO
QSI
ISHOLEV
FDDMRR
QSC
QSCI
CELLR
SET
MODE
HYST
THR
AMRFRSUPPORT
AMRHRSUPPORT
LQCACT
Page 36 of 39
Parameter
LQCIR
LQCDEFAULTMCSDL
LQCDEFAULTMCSUL
LQCHIGHMCS
LQCUNACK
LA
CHCSDL
PCUQOS
THPMBRFACTOR
QOSTHP1
QOSTHP2
CONVSTREAMTHP
GPRSQOS
IRC
FBOFFS
BAND
DLDELAY
ESDELAY
TFILIMIT
ULDELAY
USFLIMIT
DHA
DMQB
DMQBAMR
DMQG
DMQGAMR
Page 37 of 39
Parameter
DMSUPP
DMTHAMR
DTHAMR
ABISALLOC
ALLOCPREF
ANT
ANTA
ANTB
BTDM
CBCHD
CRT
CTEI
DMQBNAMR
DMQGNAMR
DMTHNAMR
DTCB
DTCBHYST
DTCBSC
DTHNAMR
EGPRSBPCLIMIT
FBCHALLOC
FLEX64KGPRS
GTDM
HNDBEFOREBANSWM
HNDRELCHINTRAM
HNDSDCCHINTI
HNDSDCCHINTOM
HNDSDCCHM
HNDSDCCHTCHM
HNDTGSOPINTRA
LATAUSED
LIMIT1
LIMIT2
LIMIT3
LIMIT4
LISTTYPE
MAXLAPDM
Page 38 of 39
Parameter
MAXNOSDCCHTRX
MAXSBLK
MAXSMSG
MBCRAC
MCCSUPPORT
MPDCH
MPWR
MSQUEUING
NDIST
NNCELLS
PAGLATA
PAGNUMBERLA
PAGREP1LA
PAGREPCT1LA
PAGREPGLOB
PAGTIMEFRST1LA
PAGTIMEFRSTGLOB
PAGTIMEREP1LA
PAGTIMEREPGLOB
PAGTIMEREPLATA
PDCHPREEMPT
PILTIMERFLEX
PRACHBLK
PRIMPLIM
PSCVL
QLENGTH
QOSMAPPING
RESLIMIT
ROMTBIPADDRLSW
ROMTBIPADDRMSW
RXD
SECPAGEPATH
SPDCH
SYNCSRC
SYSTYPE
TEI
TFMODE
TIMHNDCMDINTRAM
TIMPAGINGM
TRAFBLK
TRXC
TXID
Page 39 of 39