Sunteți pe pagina 1din 39

Parameter

Feature

Level

Class

Range

Units

Commands

DL
UL
BSPWRB
CELL
RSITE
TG

Common data
Common data
Common data
Common data
Common data
Common data

BSC
BSC
CELL
CELL
CELL
CELL

FIXED
FIXED
VARIABLE
FIXED
FIXED
VARIABLE

-12 to 12
-12 to 12
0 to 63
1 to 7 characters except ALL
3 to 15 characters
0 to 511

dB
dB
dB

RRLLC, RRLLP 0
RRLLC, RRLLP 0
RLCPC, RLCPP
RLDEI
RLDEI
RXMOI,
RXMOC,
RXMSC,
RXESE, RXESI,
RXTCI, RXTCE,
RXBLE, RXBLI,
RXPLI, RXPLE,
RXAPI, RXAPE,
RXMOP.

CGI

Common data

CELL

FIXED

CGI is MCC-MNC-LAC-CI. See range info


for each of these parameters.

RLDEC, RLDEP

MCC
MNC
LAC
CI
NCC
BCC
BCCHNO

Common data
Common data
Common data
Common data
Common data
Common data
Common data

CELL
CELL
CELL
CELL
CELL
CELL
CELL

FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED

3 digits
2 or 3 digits
1 to 65535
0 to 65535
0 to 7
0 to 7
128 to 251 (GSM 800)
512 to 810 (GSM 1900)

RLDEC, RLDEP
RLDEC, RLDEP
RLDEC, RLDEP
RLDEC, RLDEP
RLDEC, RLDEP
RLDEC, RLDEP
RLDEC, RLDEP

310
410

BCCHTYPE

Common data

CELL

FIXED

COMB, COMBC, NCOMB

RLDEC, RLDEP NCOMB

COMB for 1 TRU


NCOMB for > 1 TRU

AGBLK

Common data

CELL

FIXED

0 to 2 (COMB, COMBC)
0 to 7 (NCOMB)

RLDEC, RLDEP 1

MFRMS

Common data

CELL

FIXED

2 to 9

CCCH
RLDEC, RLDEP 6
multiframes

4 for Nortel MSC


4 or 6 for others

FNOFFSET

Common data

CELL

FIXED

0 to 1325

TDMA
frames

RLDEC, RLDEP 0

ECSC
SCTYPE
MNCDIGITHAND
TSC
MSTXPWR

Common data
Common data
Common data
Common data
Common data

CELL
CELL
BSC
CELL
CELL

FIXED
FIXED
FIXED
FIXED
VARIABLE

NO, YES
UL, OL
0 to 2
0 to 7
13 to 43 odd values (GSM 800)
4 to 30 even values (GSM 1900)

RLSBC, RLSBP NO
RLDSI
RAEPC, RAEPP 0
RLDTC, RLDTP Set to same as BCC
RLCPC, RLCPP

YES

BSPWRT
CHGR

Common data
Common data

CELL
CELL

VARIABLE
FIXED

0 to 63
0 to 15

STATE
NUMREQBPC

Common data
Common data

CELL
CELL

FIXED
FIXED

ACTIVE, HALTED
8 to 128 in steps of 8, SYSDEF

ARFCN

dBm
dBm

Ericsson Default

RLCPC, RLCPP
RLCCC,
0
RLDGI , RLCFP
RLSTC, RLSTP
RLBDC, RLBDP SYSDEF

Cingular
Recommendation
0
0

0 to 7
0 to 7
12 to 15 BCCH's

2
Set to same as BCC
30 (GSM1900)
33 (GSM800)
1,2,3
ACTIVE
8 X number of TRUs in
channel group

Page 1 of 39

Parameter

Feature

Level

Class

Range

Units

Commands

Ericsson Default

Cingular
Recommendation

DCHNO

Common data

CELL

FIXED

128 to 251 (GSM 800)


512 to 810 (GSM 1900)

ARFCN

RLCFI, RLCFE,
RLCFP

BCCD

Common data

CELL

VARIABLE

YES, NO

RLCFI, RLCFE,
RLCFP

YES

YES

SDCCH

Common data

CELL

FIXED

0 to 16
0 to 7 if CCHPOS = BCCH
0 to 3 if CCHPOS = BCCH and cell is
extended range

RLCCC, RLCFP 1

CCHPOS
TN

Common data
Common data

CELL
CELL

FIXED
FIXED

BCCH, TN
0 to 3, 0 or 2 (extended range)

RLCCC, RLCFP TN
RLCCC, RLCFP 2

CBCH
TRADROPLEVEL

Common data
Common data

CELL
BSC

FIXED
FIXED

YES, NO
0, 10 to 60, 110 to 160

RLCCC, RLCFP NO
RAEPC, RAEPP.

NO
25 - Alarm = A1
125 - Alarm = A3

TRADROPNOTRAF

Common data

BSC

FIXED

RAEPC, RAEPP.

25 or 15

CELLR

Neighbouring cell relation data

CELL

VARIABLE

1 to 7 characters except ALL

RLNRI, RLNRC,
RLNRE, RLNRP

CTYPE

Neighbouring cell relation data

CELL

VARIABLE

EXT, Omitted

RLDEI, RLLHP,
RLDEP

RELATION
CS

Neighbouring cell relation data


Neighbouring cell relation data

CELL
CELL

VARIABLE
FIXED

SINGLE, OMITTED
YES, NO

RLNRI
OMITTED
RLNRC, RLNRP NO

ACCMIN

Idle mode behaviour

CELL

VARIABLE

47 to 110

dBm

RLSSC, RLSSP 110

CCHPWR

Idle mode behaviour

CELL

FIXED

13 to 43 in steps of 2 (GSM 800)


4 to 30 in steps of 2 (GSM 1900)

dBm

RLSSC, RLSSP

30 (GSM1900)
33 (GSM800)

CRH
NCCPERM
SIMSG

Idle mode behaviour


Idle mode behaviour
Idle mode behaviour

CELL
CELL
CELL

FIXED
FIXED
FIXED

0 to 14 in steps of 2
0 to 7
1, 7, 8

dB

RLSSC, RLSSP 4
RLSSC, RLSSP
RLSMC, RLSMP SIMSG=1 MSGDIST=ON
SIMSG=7 MSGDIST=OFF
SIMSG=8 MSGDIST=OFF

4
0,1,2,3,4,5,6,7
1, ON
7, OFF
8, OFF

MSGDIST

Idle mode behaviour

CELL

FIXED

ON, OFF

RLSMC, RLSMP SIMSG=1 MSGDIST=ON 1, ON


SIMSG=7 MSGDIST=OFF 7, OFF
SIMSG=8 MSGDIST=OFF 8, OFF

CB
CBQ

Idle mode behaviour


Idle mode behaviour

CELL
CELL

FIXED
FIXED

YES, NO
HIGH, LOW

RLSBC, RLSBP NO
RLSBC, RLSBP HIGH

1 TRU = 0 (COMB)
2 TRU = 1 (NCOMB)
3 TRU = 1 (NCOMB)
4 TRU = 1 (NCOMB)
5 TRU = 2 (NCOMB)
6 TRU = 2 (NCOMB)
7 TRU = 3 (NCOMB)
8 TRU = 4 (NCOMB)
9 TRU = 4 (NCOMB)
10 TRU = 4 (NCOMB)
11 TRU = 4 (NCOMB)
12 TRU = 4 (NCOMB)

CG0: 1 to 7
CG1: 0 to 7

Omitted

YES (Co-sited)
NO (Not co-sited)
110

NO
HIGH

Page 2 of 39

Parameter

Feature

Level

Class

Range

Units

Commands

Ericsson Default

Cingular
Recommendation

ACC
MAXRET
TX
ATT
T3212

Idle mode behaviour


Idle mode behaviour
Idle mode behaviour
Idle mode behaviour
Idle mode behaviour

CELL
CELL
CELL
CELL
CELL

FIXED
FIXED
FIXED
FIXED
FIXED

0 to 15, CLEAR
1, 2, 4, 7
3 to 12, 14, 16, 20, 25, 32, 50
YES, NO
0 to 255

Deci hours

RLSBC, RLSBP
RLSBC, RLSBP
RLSBC, RLSBP
RLSBC, RLSBP
RLSBC, RLSBP

CLEAR
4
50
YES
40

CLEAR
7
32
YES
9 for standard cells
4 for MSC/BSC border
cells

CRO

Idle mode behaviour

CELL

FIXED

0 to 63

dB

RLSBC, RLSBP 0

0 for GSM1900
3 for GSM850

TO
PT
FASTASSIGN
NOOFPHYSINFOMSG
TIMER3105
EVALTYPE
TINIT

Idle mode behaviour


Idle mode behaviour
Locating
Locating
Locating
Locating
Locating

CELL
CELL
BSC
BSC
BSC
BSC
BSC

FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED

0 to 7
0 to 31
0, 1
0 to 254
0 to 254
1, 3
0 to 120

dB

RLSBC, RLSBP
RLSBC, RLSBP
RAEPC, RAEPP
RAEPC, RAEPP
RAEPC, RAEPP
RLLBC, RLLBP
RLLBC, RLLBP

0
0
0
35
4
1
10

0
0
0
35
6
3

TALLOC

Locating

BSC

FIXED

0 to 120

SACCH
periods

RLLBC, RLLBP

TURGEN

Locating

BSC

FIXED

0 to 120

SACCH
periods

RLLBC, RLLBP

TAAVELEN
SSEVALSD
QEVALSD
SSEVALSI
QEVALSI
SSLENSD

Locating
Locating
Locating
Locating
Locating
Locating

BSC
CELL
CELL
CELL
CELL
CELL

FIXED
FIXED
FIXED
FIXED
FIXED
FIXED

1 to 20
1 to 9
1 to 9
1 to 9
1 to 9
1 to 20

RLLBC, RLLBP
RLLFC, RLLFP
RLLFC, RLLFP
RLLFC, RLLFP
RLLFC, RLLFP
RLLFC, RLLFP

4
6
6
6
6
10

QLENSD

Locating

CELL

FIXED

1 to 20

SACCH
periods

RLLFC, RLLFP

10

10

SSLENSI

Locating

CELL

FIXED

1 to 20

SACCH
periods

RLLFC, RLLFP

QLENSI

Locating

CELL

FIXED

1 to 20

SACCH
periods

RLLFC, RLLFP

SSRAMPSD

Locating

CELL

FIXED

1 to 20

SACCH
periods

RLLFC, RLLFP

SSRAMPSI

Locating

CELL

FIXED

1 to 20

SACCH
periods

RLLFC, RLLFP

MISSNM
BSPWR
MSRXMIN

Locating
Locating
Locating

CELL
CELL
CELL

FIXED
VARIABLE
FIXED

0 to 18
0 to 80
0 to 150

BSRXMIN

Locating

CELL

FIXED

0 to 150

10 ms
SACCH
periods

SACCH
periods

dBm
dBm
(negative)
dBm
(negative)

10
2
2
4
6
6
6
6
10

RLLOC, RLLOP 3
RLLOC, RLLOP
RLLOC, RLLOP

3
variable
104

RLLOC, RLLOP

150

Page 3 of 39

Parameter

Feature

Level

Class

Range

Units

Commands

Ericsson Default

Cingular
Recommendation

MSRXSUFF

Locating

CELL

FIXED

0 to 150

dBm
(negative)

RLLOC, RLLOP

0 or 150

BSRXSUFF

Locating

CELL

FIXED

0 to 150

dBm
(negative)

RLLOC, RLLOP

150

BSTXPWR
KHYST
LHYST
TRHYST
KOFFSET
LOFFSET
TROFFSET
HIHYST
LOHYST
HYSTSEP

Locating
Locating
Locating
Locating
Locating
Locating
Locating
Locating
Locating
Locating

CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL

VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE
VARIABLE

0 to 80
0 to 63
0 to 63
0 to 63
63 to 63
63 to 63
63 to 63
0 to 63
0 to 63
0 to 150

dBm
dB
dB
dB
dB
dB
dB
dB
dB
dBm
(negative)

RLLOC, RLLOP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP
RLNRC, RLNRP

3
3
2
0
0
0
5
3
90

OFFSET
BADQDL
BADQUL
LOWSSDL

Locating
Locating
Locating
Locating

CELL
BSC
BSC
BSC

VARIABLE
FIXED
FIXED
FIXED

63 to 63
0 to 100
0 to 100
47 to 110

dB
dtqu
dtqu
dBm
(negative)

RLNRC, RLNRP
RAEPC, RAEPP
RAEPC, RAEPP
RAEPC, RAEPP

0
55
55
104

variable
3
3
2
0
0
0
5
3
70
0
55
55
102, 104

LOWSSUL

Locating

BSC

FIXED

47 to 110

dBm
(negative)

RAEPC, RAEPP 104

TALIM

Locating

CELL

VARIABLE

0 to 63 (normal range)
0 to 219 (extended range)

Bit periods
(bp)

RLLUC, RLLUP

62

62

PSSBQ
PSSTA
PTIMBQ
PTIMTA
BQOFFSET
BQOFFSETAFR
EXTPEN
QLIMDL

Locating
Locating
Locating
Locating
Locating
Locating
Locating
Locating

CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL

FIXED
FIXED
FIXED
FIXED
VARIABLE
VARIABLE
FIXED
VARIABLE

0 to 63
0 to 63
0 to 600
0 to 600
0 to 63
0 to 63
ON, OFF
0 to 100

dB
dB
s
s
dB
dB
dtqu

RLLPC, RLLPP
RLLPC, RLLPP
RLLPC, RLLPP
RLLPC, RLLPP
RLNRC, RLNRP
RLNRC, RLNRP
RLLOC, RLLOP
RLLUC, RLLUP

10
63
10
10
3
3
OFF
55

7
63
15
30
3
3
ON
45 non hopping
55 hopping

QLIMDLAFR

Locating

CELL

VARIABLE

0 to 100

dtqu

RLLUC, RLLUP

55

55 non hopping
65 hopping

QLIMUL

Locating

CELL

VARIABLE

0 to 100

dtqu

RLLUC, RLLUP

55

45 non hopping
55 hopping

QLIMULAFR

Locating

CELL

VARIABLE

0 to 100

dtqu

RLLUC, RLLUP

55

55 non hopping
65 hopping

PSSHF
PTIMHF
IBHOSICH
IHOSICH
SCHO
CELLQ

Locating
Locating
Locating
Locating
Locating
Locating

CELL
CELL
BSC
BSC
CELL
CELL

FIXED
FIXED
FIXED
FIXED
FIXED
FIXED

0 to 63
0 to 600
ON, OFF
ON, OFF
ON, OFF
HIGH, LOW

dB
s

RLLPC, RLLPP
RLLPC, RLLPP
RLLBC, RLLBP
RLLBC, RLLBP
RLLOC, RLLOP
RLLUC, RLLUP

63
5
OFF
OFF
OFF
HIGH

63
5
OFF
OFF
ON
HIGH

109

Page 4 of 39

Parameter

Feature

Level

Class

Range

Units

Commands

Ericsson Default

Cingular
Recommendation

MAXTA

Locating

CELL

FIXED

0 to 63 (normal range)
0 to 219 (extended range)

Bit periods
(bp)

RLLDC, RLLDP

63

63

RLINKUP

Locating

CELL

VARIABLE

1 to 63

SACCH
periods

RLLDC, RLLDP

16

32

RLINKT

Locating

CELL

VARIABLE

1 to 63

SACCH
periods

RLSSC, RLSSP 16

32

HPBSTATE

Locating

CELL

FIXED

ACTIVE, INACTIVE

RLPBI, RLPBP , INACTIVE


RLPBE

ACTIVE

CHALLOC

Channel administration /
Immediate assignment on TCH

BSC

FIXED

0 to 2

RAEPC, RAEPP 0

EBANDINCLUDED

Channel administration /
Immediate assignment on TCH

BSC

FIXED

0 and 1

RAEPC, RAEPP 0

MAXCHDATARATE

Channel administration /
Immediate assignment on TCH

BSC

FIXED

96 and 144

RAEPC, RAEPP 96

96

SPEECHVERUSED

Channel administration /
Immediate assignment on TCH

BSC

FIXED

0 and 1

RAEPC, RAEPP 1

BSCMC

Channel administration /
Immediate assignment on TCH

BSC

FIXED

ON, OFF

RLCDC ,
RLCDP

OFF

OFF

CMDR

Channel administration /
Immediate assignment on TCH

CELL

FIXED

96 and 144

RLDRC ,
RLDRP

144

144

CHAP

Channel administration /
Immediate assignment on TCH

CELL

FIXED

0 to 10

RLHPC, RLHPP 0

BCCH on overlay 6 or
8, otherwise 0 or 1.
Multiband cell = 8.

SAS

Channel administration /
Immediate assignment on TCH

CELL

FIXED

QUALITY, MAIO, MULTI

RLGAC, RLGAP QUALITY

QUALITY

NECI

Channel administration /
Immediate assignment on TCH

CELL

FIXED

0 and 1

RLSSC, RLSSP 0

MC

Channel administration /
Immediate assignment on TCH

CELL

FIXED

ON, OFF

RLCDC ,
RLCDP

OFF

CHCODING

GPRS/EGPRS Channel
Administration

BSC

FIXED

CS-1 or CS-2

RAEPC, RAEPP 2

GPRSNWMODE

GPRS/EGPRS Channel
Administration

BSC

FIXED

0 to 3

RAEPC, RAEPP 2

GPRSPRIO

GPRS/EGPRS Channel
Administration

BSC

FIXED

0 to 63

RAEPC, RAEPP 0

PILTIMER

GPRS/EGPRS Channel
Administration

BSC

FIXED

1 to 3600

RAEPC, RAEPP 20

10

EGPRSBPCLIMIT

GPRS/EGPRS Channel
Administration

BSC

FIXED

0 to 8160

BPC's

DBTSP

ONDEMANDGPHDEV

GPRS/EGPRS Channel
Administration

BSC

FIXED

1 and 256

RAEPC, RAEPP 20

20

ONDEMANDGPHDV64 GPRS/EGPRS Channel


Administration

BSC

FIXED

0 to 63

RAEPC, RAEPP 5

PSETCHKPERIOD

BSC

VARIABLE

0 to 60

RAEPC, RAEPP 5

GPRS/EGPRS Channel
Administration

min

OFF

Page 5 of 39

Parameter

Feature

Level

Class

Range

Units

Commands

Ericsson Default

TBFDLLIMIT

GPRS/EGPRS Channel
Administration

BSC

FIXED

1 to 8

RAEPC, RAEPP 2

TBFULLIMIT

GPRS/EGPRS Channel
Administration

BSC

FIXED

1 to 6

RAEPC, RAEPP 2

NACCACT

GPRS/EGPRS Channel
Administration

BSC

FIXED

0 or 1

RAEPC, RAEPP 1

PDCHPREEMPT

GPRS/EGPRS Channel
Administration

BSC

FIXED

0 to 4

GPRSSUP

GPRS/EGPRS Channel
Administration

CELL

FIXED

ON, OFF

RLGSI, RLGSE , OFF


RLGSP

ON

FPDCH

GPRS/EGPRS Channel
Administration

CELL

FIXED

0 to 8
0 to 4 (extended range)

RLGSC, RLGSP 0

SCALLOC

GPRS/EGPRS Channel
Administration

CELL

FIXED

UL, OL, BOTH UL, BOTH, OL

RAEPC, RAEPP UL

BOTHUL (FPDCH in
Underlaid)
BOTHOL (FPDCH in
Overlaid)

PDCHALLOC

GPRS/EGPRS Channel
Administration

CELL

FIXED

NOPREF, FIRST, LAST

RLGSC, RLGSP NOPREF

FIRST

PSKONBCCH

GPRS/EGPRS Channel
Administration

CELL

FIXED

ENABLED, DISABLED

RLGSC, RLGSP ENABLED

ENABLED

NUMREQCS3CS4BPC

GPRS/EGPRS Channel
Administration

CELL

FIXED

0 to 128

RLBDC, RLBDP 0

NUMREQEGPRSBPC

GPRS/EGPRS Channel
Administration

CELL

FIXED

0 to 128

RLBDC, RLBDP 0

TN7BCCH

GPRS/EGPRS Channel
Administration

CELL

FIXED

EGPRS, GPRS

RLBDC, RLBDP GPRS

GPRS

GPRSEDAACT

GPRS/EGPRS Channel
Administration

BSC

FIXED

0 or 1

RAEPC, RAEPP 0

PULSCHEDINT

GPRS/EGPRS Channel
Administration

BSC

FIXED

0 to 10, 99

RAEPC, RAEPP 0

DMPSTATE

Dynamic MS Power Control

CELL

FIXED

ACTIVE or INACTIVE

RLPCI, RLPCE,
RLPCP

INACTIVE

ACTIVE

AMRPCSTATE

Dynamic MS Power Control

CELL

FIXED

ACTIVE or INACTIVE

RLAPI, RLAPE,
RLAPP

INACTIVE

ACTIVE

SSDESUL

Dynamic MS Power Control

CELL

VARIABLE

47 to 110

dBm
(negative)

RLPCC, RLPCP 85

104

SSDESULAFR

Dynamic MS Power Control

CELL

VARIABLE

47 to 110

dBm
(negative)

RLAPC, RLAPP 85

104

SSLENUL

Dynamic MS Power Control

CELL

FIXED

3 to 15

SACCH
periods

RLPCC, RLPCP 5

LCOMPUL
QDESUL
QDESULAFR
QLENUL

Dynamic MS Power Control


Dynamic MS Power Control
Dynamic MS Power Control
Dynamic MS Power Control

CELL
CELL
CELL
CELL

VARIABLE
VARIABLE
VARIABLE
FIXED

0 to 100
0 to 70
0 to 70
1 to 20

%
dtqu
dtqu
SACCH
periods

RLPCC, RLPCP
RLPCC, RLPCP
RLAPC, RLAPP
RLPCC, RLPCP

6
20
40
3

70
20
20
8

Cingular
Recommendation

1 (R10)
4 (R11)

Page 6 of 39

Parameter

Feature

Level

Class

Range

Units

Commands

QCOMPUL
REGINTUL

Dynamic MS Power Control


Dynamic MS Power Control

CELL
CELL

VARIABLE
FIXED

0 to 100
1 to 30

%
SACCH
periods

RLPCC, RLPCP 30
RLPCC, RLPCP. 5

90
1

DTXFUL

Dynamic MS Power Control

CELL

FIXED

0 to 40

SACCH
periods

RLPCC, RLPCP 5

STEPLIMDL
ALPHA

Dynamic MS Power Control


GPRS/EGPRS Dynamic MS
Power Control

BSC
BSC

FIXED
VARIABLE

ON, OFF
0 to 10

0.1

OFF
RAEPC, RAEPP 0

OFF
0

GAMMA

GPRS/EGPRS Dynamic MS
Power Control

CELL

VARIABLE

0 to 62, even values

dB

RLGSC, RLGSP 0

AMRPCSTATE

Dynamic BTS Power Control

CELL

FIXED

ACTIVE or INACTIVE

RLAPI, RLAPE,
RLAPP

INACTIVE

ACTIVE

UPDWNRATIO
DBPSTATE

Dynamic BTS Power Control


Dynamic BTS Power Control

BSC
CELL

FIXED
FIXED

100 to 700
ACTIVE or INACTIVE

RAEPC, RAEPP 200


RLBCI, RLBCE, INACTIVE
RLBCP

200
ACTIVE

SDCCHREG
SSDESDL

Dynamic BTS Power Control


Dynamic BTS Power Control

CELL
CELL

FIXED
VARIABLE

ON, OFF
47 to 110

RLBCC, RLBCP OFF


RLBCC, RLBCP 70

ON
90 or 93

SSDESDLAFR

Dynamic BTS Power Control

CELL

VARIABLE

47 to 110

dBm
(negative)

RLAPC, RLAPP 70

96

REGINTDL

Dynamic BTS Power Control

CELL

FIXED

1 to 10

SACCH
periods

RLBCC, RLBCP 5

SSLENDL

Dynamic BTS Power Control

CELL

FIXED

3 to 15

SACCH
periods

RLBCC, RLBCP 5

LCOMPDL
QDESDL
QDESDLAFR
QCOMPDL
QLENDL

Dynamic BTS Power Control


Dynamic BTS Power Control
Dynamic BTS Power Control
Dynamic BTS Power Control
Dynamic BTS Power Control

CELL
CELL
CELL
CELL
CELL

VARIABLE
VARIABLE
VARIABLE
VARIABLE
FIXED

0 to 100
0 to 70
0 to 70
0 to 60
1 to 20

%
dtqu
dtqu
%
SACCH
periods

RLBCC, RLBCP
RLBCC, RLBCP
RLAPC, RLAPP
RLBCC, RLBCP
RLBCC, RLBCP

5
30 to 40
40
50 to 55
3

BSPWRMIN
DTXD
DTXU
HOP

Dynamic BTS Power Control


Discontinuous Transmission
Discontinuous Transmission
Frequency Hopping

CELL
CELL
CELL
CELL

FIXED
FIXED
FIXED
FIXED

20 to +50
ON, OFF
0 to 2
ON, OFF, TCH

dBm

RLBCC, RLBCP 20
RLCXC, RLCXP OFF
RLSSC, RLSSP
RLCHC, RLCFP OFF

HSN
FHOP

Frequency Hopping
Frequency Hopping

CELL
CELL

VARIABLE
VARIABLE

0 to 63
BB, SY

RLCHC, RLCFP
RXMOC,
RXMOP

COMB

Frequency Hopping

CELL

VARIABLE

FLT, HYB

RXMOI,
RXMOC,
RXMOP

CONFMD

Frequency Hopping

CELL

VARIABLE

NODEL, CMD, FASTREC, MINDIST

RXMSC,
RXMOC,
RXMOP

MAIO

MAIO Management

CELL

VARIABLE

0 to 63 or DEFAULT

RLCHC, RLCFP DEFAULT

dBm
(negative)

Ericsson Default

70
20
20
30
8

Cingular
Recommendation

-20
ON
1
ON for TCH
OFF for BCCH
SY
HYB

NODEL

MINDIST

Page 7 of 39

Parameter

Feature

Level

Class

Range

IHO
TMAXIHO
TIHO
MAXIHO
QOFFSETUL

Intra-Cell Handover
Intra-Cell Handover
Intra-Cell Handover
Intra-Cell Handover
Intra-Cell Handover

CELL
CELL
CELL
CELL
CELL

FIXED
FIXED
FIXED
VARIABLE
VARIABLE

ON, OFF
0 to 60
0 to 60
0 to 15
50 to +50

QOFFSETULAFR

Intra-Cell Handover

CELL

VARIABLE

QOFFSETDL

Intra-Cell Handover

CELL

QOFFSETDLAFR

Intra-Cell Handover

SSOFFSETUL
SSOFFSETULAFR
SSOFFSETDL
SSOFFSETDLAFR
ASSOC
IBHOASS
AW
CAND
AWOFFSET
SCLDTIMEINT

Units

Commands

Ericsson Default

Cingular
Recommendation

dtqu

RLIHC, RLIHP
RLIHC, RLIHP
RLIHC, RLIHP
RLIHC, RLIHP
RLIHC, RLIHP

OFF
6
10
3
0

ON
6
10
1
-5 for hopping
-14 for fixed

50 to +50

dtqu

RLIHC, RLIHP

5 for hopping
0 for fixed

VARIABLE

50 to +50

dtqu

RLIHC, RLIHP

-5 for hopping
-14 for fixed

CELL

VARIABLE

50 to +50

dtqu

RLIHC, RLIHP

5 for hopping
0 for fixed

Intra-Cell Handover
Intra-Cell Handover
Intra-Cell Handover
Intra-Cell Handover
Assignment to Other Cell
Assignment to Other Cell
Assignment to Other Cell
Assignment to Other Cell
Assignment to Other Cell
Overlaid / Underlaid Subcells /
Subcell Load Distribution

CELL
CELL
CELL
CELL
BSC
BSC
CELL
CELL
CELL
BSC

VARIABLE
VARIABLE
VARIABLE
VARIABLE
FIXED
FIXED
FIXED
FIXED
VARIABLE
VARIABLE

30 to +30
30 to +30
30 to +30
30 to +30
ON, OFF
ON, OFF
ON, OFF
AWN, NHN, BOTH
0 to 63
100 to 1000

dB
dB
dB
dB

RLIHC, RLIHP
RLIHC, RLIHP
RLIHC, RLIHP
RLIHC, RLIHP
RLLBC, RLLBP
RLLBC, RLLBP
RLLOC, RLLOP
RLNRC, RLNRP
RLNRC, RLNRP
RAEPC, RAEPP

0
0
0
0
OFF
OFF
OFF
BOTH
3
100

24
24
16
16
ON
ON
ON
BOTH
5
100

SCLD

Overlaid / Underlaid Subcells /


Subcell Load Distribution

CELL

FIXED

ON, OFF

RLLLC, RLLLP

OFF

ON for markets with


overlay/underlay. OFF
otherwise.

SCLDLL

Overlaid / Underlaid Subcells /


Subcell Load Distribution

CELL

VARIABLE

0 to 99

RLLLC, RLLLP

20

20

SCLDUL

Overlaid / Underlaid Subcells /


Subcell Load Distribution

CELL

VARIABLE

0 to 100

RLLLC, RLLLP

30

30

LOL

Overlaid / Underlaid Subcells /


Subcell Load Distribution

CELL

VARIABLE

0 to 200

dB

RLOLC, RLOLP

200

LOLHYST

Overlaid / Underlaid Subcells /


Subcell Load Distribution

CELL

VARIABLE

0 to 63

dB

RLOLC, RLOLP 3

TAOL

Overlaid / Underlaid Subcells /


Subcell Load Distribution

CELL

VARIABLE

0 to 61

Bit periods

RLOLC, RLOLP

61

TAOLHYST

Overlaid / Underlaid Subcells /


Subcell Load Distribution

CELL

VARIABLE

0 to 61

Bit periods

RLOLC, RLOLP

HCSBANDHYST
THO
NHO
HCSBAND
HCSBANDTHR

Hiearchical Cell Structures


Hiearchical Cell Structures
Hiearchical Cell Structures
Hiearchical Cell Structures
Hiearchical Cell Structures

BSC
BSC
BSC
BSC
BSC

VARIABLE
FIXED
FIXED
VARIABLE
FIXED

0 to 63
10 to 100
2 to 10
1 to 8
0 to 150

dB
s

RLHBC, RLHBP
RLLBC, RLLBP
RLLBC, RLLBP
RLHBC, RLHBP
RLHBC, RLHBP

s
s

dB
ms

dBm
(negative)

2
30
3
95

2
30
3
2
2

Page 8 of 39

Parameter

Feature

Level

Class

Range

Units

Commands

Ericsson Default

Cingular
Recommendation

LAYER

Hiearchical Cell Structures

CELL

FIXED

1 to 8

RLLHC, RLLHP

2 (GSM1900)
3 (GSM800)

LAYERTHR

Hiearchical Cell Structures

CELL

FIXED

0 to 150

dBm
(negative)

RLLHC, RLLHP

75

95 (GSM1900)
85 (GSM800)

LAYERHYST
PSSTEMP
PTIMTEMP
FASTMSREG
XRANGE
MBCCHNO

Hiearchical Cell Structures


Hiearchical Cell Structures
Hiearchical Cell Structures
Hiearchical Cell Structures
Extended Range
Double BA Lists

CELL
CELL
CELL
CELL
CELL
CELL

FIXED
FIXED
FIXED
FIXED
FIXED
FIXED

0 to 63
0 to 63
0 to 600
ON, OFF
YES, NO
128 to 251 (GSM 800)
512 to 810 (GSM 1900)

dB
dB
s

RLLHC, RLLHP
RLLHC, RLLHP
RLLHC, RLLHP
RLLHC, RLLHP
RLDEC, RLDEP
RLMFC, RLMFP

2
0
0
OFF
NO

3
0
0
OFF
NO

ICMSTATE

Idle Channel Measurements

CELL

FIXED

ACTIVE, PASSIVE, NOALLOC

RLIMI, RLIMP ,
RLIME

PASSIVE

ACTIVE

INTAVE

Idle Channel Measurements

CELL

FIXED

1 to 31

RLIMC, RLIMP

25

LSSTATE

Cell Load Sharing

BSC

FIXED

ACTIVE, INACTIVE

RLLSI, RLLSE,
RLLSP

INACTIVE

INACTIVE

CLSTIMEINTERVAL
CLSSTATE

Cell Load Sharing


Cell Load Sharing

BSC
CELL

VARIABLE
FIXED

100 to 1000
ACTIVE, INACTIVE

ms

RAEPC, RAEPP 100


RLLCI, RLLCE, INACTIVE
RLLCP

100
INACTIVE

CLSACC
CLSLEVEL
CLSRAMP
HOCLSACC
RHYST
CLMRKMSG
MODE

Cell Load Sharing


Cell Load Sharing
Cell Load Sharing
Cell Load Sharing
Cell Load Sharing
Multiband Operation
Multiband Operation

CELL
CELL
CELL
CELL
CELL
BSC
BSC

VARIABLE
VARIABLE
FIXED
VARIABLE
VARIABLE
FIXED
FIXED

1 to 100
0 to 99
0 to 30
ON, OFF
0 to 100
0 to 3
MULTI, SINGLE

%
%
s

RLLCC, RLLCP
RLLCC, RLLCP
RLLCC, RLLCP
RLLCC, RLLCP
RLLCC, RLLCP
RAEPC, RAEPP
RLOMC,
RLOMP

40
20
16
ON
75
0
Single or Multi

GSYSTYPE

Multiband Operation

BSC

FIXED

GSM800, GSM900, GSM1800, GSM1900,


MIXED

RLTYC, RLTYI,
RLTYP

CSYSTYPE

Multiband Operation

CELL

FIXED

GSM800, GSM900, GSM1800, GSM1900

RLDEI, RLDEP

MBCR
DCAHANDOVER
DCASTATE

Multiband Operation
Differential Channel Allocation
Differential Channel Allocation

CELL
BSC
BSC

FIXED
FIXED

0 to 3
0, 1
ON, OFF

RLSSC, RLSSP 0
RAEPC, RAEPP 0
RLDCI, RLDCE , OFF
RLDCP

EMERGPRL
STATSINT

Differential Channel Allocation


Differential Channel Allocation

BSC
BSC

FIXED
FIXED

1 to 15
1 to 96

CHTYPE
CHRATE
PHSTATE

Differential Channel Allocation


Differential Channel Allocation
Enhanced Multi-Level
Precedence and Pre-Emption
Service

CELL
CELL
BSC

TCH, SDCCH
FR, HR
0,1

ARFCN

SACCH
periods

15 min.
periods

40
20
5
OFF
75
0
SINGLE

Mixed or GSM1900
GSM800 or GSM1900

GSM800 or GSM1900
0, 2 or 3
0
OFF

RLDCI , RLDCP
RLSCI, RLSCP
RLPRC, RLPRP
RLPRC, RLPRP
RAEPC, RAEPP 0

Page 9 of 39

Parameter

Feature

Level

Class

Range

Units

Commands

Ericsson Default

Cingular
Recommendation

ACSTATE

Adaptive Configuration of
Logical Channels

CELL

FIXED

ON, OFF

RLACI, RLACE,
RLACP

OFF

ON

SLEVEL

Adaptive Configuration of
Logical Channels

CELL

FIXED

0 to 2, CONG

RLACC, RLACP 0

STIME

Adaptive Configuration of
Logical Channels

CELL

FIXED

15 to 360

RLACC, RLACP 20

40

COEXUMTS

GSM - UMTS Cell Reselection


and Handover

BSC

0, 1

RAEPC, RAEPP 0

0, 1

COEXUMTSINT

GSM - UMTS Cell Reselection


and Handover

BSC

100 to 1000

RAEPC, RAEPP 1000

1000

UMFI

GSM - UMTS Cell Reselection


and Handover

CELL

MFDDARFCN: 0 to 16383
MSCRCODE: 0 to 511
DIVERSITY: DIV or NODIV

FDDQMIN

GSM - UMTS Cell Reselection


and Handover

CELL

0 to 7

dB (relative
to -20)

RLSUC, RLSUP 0

FDDQOFF

GSM - UMTS Cell Reselection


and Handover

CELL

0 to 15

dB

RLSUC, RLSUP 8

SPRIO

GSM - UMTS Cell Reselection


and Handover

CELL

NO, YES

RLSUC, RLSUP NO

YES

QSI

GSM - UMTS Cell Reselection


and Handover

CELL

0 to 15

4 dB from
-98dBm

RLSUC, RLSUP 15

ISHOLEV

GSM - UMTS Cell Reselection


and Handover

CELL

0 to 99

RLLOC, RLLOP 20

99

FDDMRR

GSM - UMTS Cell Reselection


and Handover

CELL

0 to 3

RLSUC, RLSUP 0

QSC

GSM - UMTS Cell Reselection


and Handover

CELL

0 to 15

RLSUC, RLSUP 15

15

QSCI

GSM - UMTS Cell Reselection


and Handover

CELL

0, 1

RLSUC, RLSUP 0

CELLR

GSM - UMTS Cell Reselection


and Handover

CELL

1 to 7 characters except ALL

RLNRI, RLNRE,
RLNRP, RLNCP

SET
MODE

Adaptive Multi-Rate
Adaptive Multi-Rate

BSC
BSC

FIXED
FIXED

FR3, FR4, HR3, HR4


1 to 5 (Half Rate)
1 to 8 (Full Rate)

RLADC, RLADP
RLADC, RLADP

HYST
THR
AMRFRSUPPORT
AMRHRSUPPORT
LQCACT

Adaptive Multi-Rate
Adaptive Multi-Rate
Adaptive Multi-Rate
Adaptive Multi-Rate
Link Quality Control in EGPRS

BSC
BSC
BSC
BSC
BSC

FIXED
FIXED
FIXED
FIXED
FIXED

0 to 15
0 to 63
0 to 4
0 to 4
0, 1

ms

RLUMC,
RLUMP

4 dB from
-98dBm

0.5 dB
0.5 dB

RLADC, RLADP
RLADC, RLADP
RAEPC, RAEPP 0
RAEPC, RAEPP 0
RAEPC, RAEPP 0

1
1
3

Page 10 of 39

Parameter

Feature

Level

Class

Range

LQCIR
LQCDEFAULTMCSDL
LQCDEFAULTMCSUL
LQCHIGHMCS
LQCUNACK
LA
CHCSDL
PCUQOS

Link Quality Control in EGPRS


Link Quality Control in EGPRS
Link Quality Control in EGPRS
Link Quality Control in EGPRS
Link Quality Control in EGPRS
GPRS Link Adaptation
GPRS Link Adaptation
GPRS/EGPRS Quality of Service

BSC
BSC
BSC
BSC
BSC
CELL
CELL
BSC

FIXED
FIXED
FIXED
FIXED
FIXED
VARIABLE
VARIABLE
FIXED

THPMBRFACTOR

GPRS/EGPRS Quality of Service BSC

QOSTHP1

Units

Commands

Ericsson Default

Cingular
Recommendation

0, 1
MCS-1to MCS-9
MCS-1to MCS-9
MCS-1to MCS-9
0 to 2
ON, OFF
NA, CS-1 to CS-4
0, 1

RAEPC, RAEPP
RAEPC, RAEPP
RAEPC, RAEPP
RAEPC, RAEPP
RAEPC, RAEPP
RLGSC, RLGSP
RLGSC, RLGSP
RAEPC, RAEPP

1
MCS-5
MCS-5
MCS-9
1
ON
CS-2
0

1
5
3
9
1
OFF
CS-2
0

FIXED

0 to 10

RAEPC, RAEPP 0

GPRS/EGPRS Quality of Service BSC

FIXED

1 to 10

RAEPC, RAEPP 3

QOSTHP2

GPRS/EGPRS Quality of Service BSC

FIXED

1 to 10

RAEPC, RAEPP 2

CONVSTREAMTHP

GPRS/EGPRS Quality of Service BSC

FIXED

1 to 3

RAEPC, RAEPP 1

GPRSQOS

GPRS/EGPRS Channel
Administration

BSC

FIXED

0 to 1

DBTSP

0 - Legacy Orange
BSCs
1 - Legacy Blue BSCs

IRC

Interference Rejection
Combining

CELL

FIXED

ON, OFF

RLDEC, RLDEP OFF

ON

FBOFFS
BAND

Multi Band Cell


Multi Band Cell

CELL
CELL

VARIABLE
FIXED

-40 to 40
GSM800, GSM900, GSM1800, GSM1900

dB

RLLOC, RLLOP 0
RLDGI , RLDGP

-10
GSM800 or GSM1900

DLDELAY

GPRS/EGPRS Connection
Control And Transfer

BSC

FIXED

0 to 5000

ms

RAEPC, RAEPP 2200

1000

ESDELAY

GPRS/EGPRS Connection
Control And Transfer

BSC

FIXED

0 to 2000

ms

RAEPC, RAEPP 750

500

TFILIMIT

GPRS/EGPRS Connection
Control And Transfer

BSC

FIXED

0 to 31

RAEPC, RAEPP 4

ULDELAY

GPRS/EGPRS Connection
Control And Transfer

BSC

FIXED

1000

RAEPC, RAEPP 1000

2000

USFLIMIT

GPRS/EGPRS Connection
Control And Transfer

BSC

FIXED

0 to 6

RAEPC, RAEPP 2

DHA
DMQB

Dynamic AMR HR Allocation


Dynamic FR/HR Mode
Adaptation

CELL
CELL

FIXED
FIXED

ON, OFF
ON, OFF

RLDHC, RLDHP OFF


RLDMC,
OFF
RLDMP

ON
ON

DMQBAMR

Dynamic FR/HR Mode


Adaptation

CELL

VARIABLE

0 to 100

RLDMC,
RLDMP

50

50

DMQG

Dynamic FR/HR Mode


Adaptation

CELL

FIXED

ON, OFF

RLDMC,
RLDMP

OFF

ON

DMQGAMR

Dynamic FR/HR Mode


Adaptation

CELL

VARIABLE

0 to 100

RLDMC,
RLDMP

35

30

dtqu

dtqu

Page 11 of 39

Parameter

Feature

Level

Class

Range

DMSUPP

Dynamic FR/HR Mode


Adaptation

CELL

FIXED

ON, OFF

DMTHAMR

Dynamic FR/HR Mode


Adaptation

CELL

VARIABLE

0 to 100

DTHAMR

Dynamic AMR HR Allocation

CELL

VARIABLE

ABISALLOC
ALLOCPREF
ANT
ANTA
ANTB
BTDM
CBCHD
CRT
CTEI
DMQBNAMR
DMQGNAMR
DMTHNAMR

Flexible Abis
DTM
Hardware
Hardware
Hardware
GPRS
GPRS
Ericsson MSC
Hardware
AMR
AMR
AMR

CELL
CELL
CELL
CELL
CELL
BSC
CELL
BSC
CELL
CELL
CELL
CELL

VARIABLE
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED

Fixed, Flexible
QUAL, PACK
1-7 Character
1-7 Character
1-7 Character
6 to 1530 in steps of 6, OFF
Yes, No
RCR-SCRT
58 to 62
0 to 100
0 to 100
0 to 100

DTCB

Overlaid / Underlaid Subcells /


Subcell Load Distribution

CELL

VARIABLE

-63 to 63

DTCBHYST

Overlaid / Underlaid Subcells /


Subcell Load Distribution

CELL

VARIABLE

0 to 63

DTCBSC
DTHNAMR
EGPRSBPCLIMIT

Overlaid / Underlaid Subcells /


Subcell Load Distribution
AMR
GPRS

BSC
CELL
BSC

VARIABLE
FIXED
FIXED

0,1
0 to 100
0-8160

0
20

0
0
2048

BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
CELL
CELL
CELL
CELL
CELL
CELL

VARIABLE
VARIABLE
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED

0-2 2
0-1
0 to 255
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 to 2500
0 or 1
0 to 59
1 to 60
2 to 61
3 to 62
ACTIVE, IDLE, Omitted
5 to 12

2
0

2
0

FBCHALLOC
FLEX64KGPRS
GTDM
HNDBEFOREBANSWM
HNDRELCHINTRAM
HNDSDCCHINTI
HNDSDCCHINTOM
HNDSDCCHM
HNDSDCCHTCHM
HNDTGSOPINTRA
LATAUSED
LIMIT1
LIMIT2
LIMIT3
LIMIT4
LISTTYPE
MAXLAPDM

Channel administration /
Immediate assignment on TCH
Flexible Abis
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Idle Channel Measurements
Idle Channel Measurements
Idle Channel Measurements
Idle Channel Measurements
Neighbor
DTM

Units

Commands

Ericsson Default

Cingular
Recommendation

RLDMC,
RLDMP

OFF

ON only in good
environment.

RLDMC,
RLDMP

20

start at 20
conservative.

RLDHC, RLDHP 20

start at 20
conservative.
Fixed
QUAL

Fixed
QUAL

OFF
No

120
NO

45
30
20

100
0
0

-63

Rxlev
Rxlev
Rxlev
Rxlev

1
1
1
1
1
1
80
0
2
6
12
22

RLIMC, RLIMP
RLIMC, RLIMP
RLIMC, RLIMP
RLIMC, RLIMP

1
1
1
1
1
1
80
0
1
3
6
12

Page 12 of 39

Parameter

Feature

Level

Class

Range

MAXNOSDCCHTRX
MAXSBLK
MAXSMSG
MBCRAC
MCCSUPPORT
MPDCH
MPWR
MSQUEUING

Channel administration /
Immediate assignment on TCH
GPRS
GPRS
GPRS
other
GPRS
Hardware
Wireless Priority Queing

BSC
CELL
CELL
BSC
BSC
CELL
CELL
BSC

VARIABLE
FIXED
FIXED
FIXED
FIXED
FIXED
VARIABLE
FIXED

1 to 4
1 to 4
1 to 16
0-1
0-2
Yes, No
0 to 63
0-1

NDIST

Overlaid / Underlaid Subcells /


Subcell Load Distribution

CELL

VARIABLE

NNCELLS
PAGLATA
PAGNUMBERLA
PAGREP1LA
PAGREPCT1LA
PAGREPGLOB
PAGTIMEFRST1LA
PAGTIMEFRSTGLOB
PAGTIMEREP1LA
PAGTIMEREPGLOB
PAGTIMEREPLATA
PDCHPREEMPT
PILTIMERFLEX
PRACHBLK
PRIMPLIM
PSCVL
QLENGTH
QOSMAPPING
RESLIMIT
ROMTBIPADDRLSW
ROMTBIPADDRMSW
RXD
SECPAGEPATH
SPDCH
SYNCSRC
SYSTYPE
TEI
TFMODE
TIMHNDCMDINTRAM
TIMPAGINGM
TRAFBLK
TRXC
TXID

Overlaid / Underlaid Subcells /


Subcell Load Distribution
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
Ericsson MSC
GPRS
Flexible Abis
GPRS
GPRS
Ericsson MSC
Wireless Priority Queing
GPRS
Wireless Priority Queing
Remote OMT
Remote OMT
Hardware
Ericsson MSC
GPRS
Hardware
Common data
Hardware
Hardware
Ericsson MSC
Ericsson MSC
GPRS
Hardware
Hardware

CELL
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
BSC
CELL
BSC
CELL
CELL
BSC
CELL
BSC
CELL
BSC
BSC
CELL
BSC
CELL
BOTH
CELL
CELL
CELL
BSC
BSC
CELL
CELL
CELL

VARIABLE
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
VARIABLE
VARIABLE
VARIABLE
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED

Units

Commands

Ericsson Default

Cingular
Recommendation
1
2
7
0
0

No

1
2
7
0
1
No

0 to 63

10

10

1 to 5
0 or 1
1 to3
0 to 3
0 to 3
0 or 1
2 to 10
2 to 10
2 to 10
2 to 10
2 to 10
0-4
0-100
1 to 12
1 to 8
FRV1, FRV2, FRV3, HRV1, HRV2, HRV3
0 to 32
0 to 2
1 to 100
0-65535
0-65535
A, B, AB
0 to 2
0 to 16
INTI, INTE, PCM, DEFAULT
GSM1900/GSM850
0 to 63 for G12, 0 to 57 for G01
M, S, SA
5 to 120
2 to 20
0 to 10
0 to 15
0 to 15

3
0
1
2
2
0
4
4
7
7
7
0
50
4
8

3
0
1
2
2
0
4
4
7
7
7
4
50
4
8

5
0
25
0
0

5
2
25
0
0
AB

1
0
DEFAULT
GSM1900

1
0
C
*

5
9
0

5
9
0

Page 13 of 39

Parameter

Comments

DL
UL
BSPWRB
CELL
RSITE
TG

Downlink Line level


Uplink Line Level.
BS output power for the BCCH channel
Cell Name
Radio Site Name. Identity of the radio site where the transceiver group (TG) is located.
Transceiver group (TG) identity.

CGI

Cell Global Identity

MCC
MNC
LAC
CI
NCC
BCC
BCCHNO

Mobile Country code


Mobile Network Code.
Location Area Code
Cell Identity code
Network Color Code.
Base Station Color Code.
Absolute RF channel number for BCCH.

BCCHTYPE

Whether BCCH is combined with SDCCH/4, not combined with SDCCH/4, or combined with SDCCH/4+CBCH.

AGBLK

No. CCCH blocks reserved for access grants, 1 if Sys info 7 & 8 or CBCH used with non combined SDCCH (i.e. BCCHTYPE = NCOMB, SDCCH = 1 or more and CBCH = YES) AGBLK = 0 if
BCCHTYPE = COMB

MFRMS

No. paging multiframes; 4 - Nortel MSC, 6 - all other MSC type

FNOFFSET

Offset in TDMA timing between cells at a synchronized site.

ECSC
SCTYPE
MNCDIGITHAND
TSC
MSTXPWR

Indicates whether MS in the cell is allowed to use early class mark sending
Subcell type. S-BCCH cell type - UL for 850MHz and OL for 1900MHz
0: 2-digit MNC sent. 1: 3-digit MNC sent on A-interface and 2-digit on Um. 2: 3-digit MNC sent
Training Sequence Code.
Maximum MS power while maintaining a TCH connection

BSPWRT
CHGR

BS output power for the non-BCCH channels


Channel group number. 0 - BCCH, 1- 1900 Hopping, 2- 850 Hopping or 2nd 1900 Cabinet Hopping set

STATE
NUMREQBPC

SYSDEF should only be used for cells with a single CHGR. If more than 1 CHGR is setup then NUMREQBPC should be set to 8 times the number of TRX required in the CHGR.

Page 14 of 39

Parameter

Comments

DCHNO

Absolute RF channel number.

BCCD

Defines if the channel group frequencies are allowed for Immediate Assignment.

SDCCH

Dependent upon the quantity of TRXs. If cell is XRANGE then limit is 3

CCHPOS
TN

Timeslot on which SDCCH/8 will be defined. CHGR0: 1- 7, CHR1 or greater: 0-7.

CBCH
TRADROPLEVEL

Flag for whether Cell Broadcast Channel is defined. Set to NO when BCCHTYPE COMBC is used
Transcoder threshold for high dropped call rate

TRADROPNOTRAF
CELLR

Related cell designation.

CTYPE

External cell that belongs to another BSC

RELATION
CS

The parameter is only specified when the relation is oneway.


Co-site, which indicates if a cell shares the same site as its neighbor. S-BCCH cell type = YES.

ACCMIN

Minimum RxLev at MS to access a cell: Urban/Suburban/Rural -110 dBm

CCHPWR

Maximum power a MS can use when accessing a cell

CRH
NCCPERM
SIMSG

Cell Reselect Hysteresis for location area boundaries


Permitted network color codes for meas. Reports
System Information BCCH Message distribution.

MSGDIST

System Information BCCH Message distribution.

CB
CBQ

Barring of cell (prevents cell access (not h/o in))


Defines cell priority for phase 2 idle mode selection

Page 15 of 39

Parameter

Comments

ACC
MAXRET
TX
ATT
T3212

Access Control Class barring


Max. no. random access retries on RACH
spreading of retransmissions on the RACH
Flag to initiate IMSI Attach/Detach
Periodic location update timer period

CRO

Offset between cells for idle mode selection.

TO
PT
FASTASSIGN
NOOFPHYSINFOMSG
TIMER3105
EVALTYPE
TINIT

Negative temp. offset applied on top of CRO


Duration for which temporary offset applied
Specifies if Locating shall wait before sending the requested candidate list
Indicates the maximum number of repetitions of physical information messages during the handover procedure
Defines the time between repetitions of physical information messages during the handover procedure.
Choice of handover algorithm
Min. time before handover after call init. or handover

TALLOC

Min. time between allocation attempts for better cell

TURGEN

Min. time between allocation attempts for urgency

TAAVELEN
SSEVALSD
QEVALSD
SSEVALSI
QEVALSI
SSLENSD

Timing Advance (TA) averaging window length


RxLev averaging filter type on TCH
RxQual averaging filter type on TCH
RxLev averaging filter type on SDCCH
RxQual averaging filter type on SDCCH
Length of RxLev aver. filter for SSEVALSD = 6 - 9

QLENSD

Length of RxQual aver. filter for QEVALSD = 6 - 9

SSLENSI

Length of RxLev aver. filter for SSEVALSI = 6 - 9

QLENSI

Length of RxQual aver. filter for QEVALSI = 6 - 9

SSRAMPSD

Time to ramp up N-cell measurements on TCH

SSRAMPSI

Time to ramp up N-cell measurements on SDCCH STATE ACTIVE or HALTED C F Cell or Channel Group state.

MISSNM
BSPWR
MSRXMIN

Max. allowed missing meas. reports before reset


Tx power on BCCH carrier (at reference point)
Min. SS at MS to consider n-cell a h/o candidate

BSRXMIN

Min. SS at BTS to consider n-cell a h/o candidate

Page 16 of 39

Parameter

Comments

MSRXSUFF

Sufficient SS at MS to consider cell for PL ranking

BSRXSUFF

Sufficient SS at a BTS to consider cell for PL rank

BSTXPWR
KHYST
LHYST
TRHYST
KOFFSET
LOFFSET
TROFFSET
HIHYST
LOHYST
HYSTSEP

Tx power on non-BCCH carrier (at reference point)


Hysteresis applied when both cells ranked on SS
applied when both cells ranked on PL
Hysteresis when in transition between K and L
Signal strength offset when evaluating K-cells.
Offset applied when both cells are ranked on PL
Offset when in transition between K and L
SS hysteresis when evaluating high SS cells
SS hysteresis when evaluating low SS cells
SS hysteresis when evaluating high SS cells

OFFSET
BADQDL
BADQUL
LOWSSDL

SS offset
DL BQ limit used for urgency counter - not used in HO algorithm
UL BQ limit used for urgency counter - not used in HO algorithm
DL low SS limit used for counter - not used in HO algorithm

LOWSSUL

UL low SS limit used for counter - not used in HO algorithm

TALIM

Timing advance threshold for handover

PSSBQ
PSSTA
PTIMBQ
PTIMTA
BQOFFSET
BQOFFSETAFR
EXTPEN
QLIMDL

SS penalty on cell from which h/o occurs (RxQual)


SS penalty on cell from which h/o occurs (TA)
Duration of penalty PSSBQ for RxQual h/o
Duration of penalty PSSTA for TA h/o
Bad RxQual h/o corridor or negative hysteresis
Bad RxQual h/o corridor or negative hysteresis for AMR FR.
Flag to enable penalty "transfer" for inter-BSC h/o
RxQual threshold at MS for h/o. Lower threshold used for cells hopping over 6 or more frequencies, 55 if cell is hopping

QLIMDLAFR

RxQual threshold at MS for h/o. Lower threshold used for cells hopping over 6 or more frequencies, 55 if cell is not hopping *QLIMUL 0-100 55 45 C V RxQual threshold at BTS for h/o. Lower
threshold used for cells hopping over 6 or more frequencies, 55 if cell is hopping

QLIMUL

Quality limit uplink for handover. Urgency detection parameter.

QLIMULAFR

RxQual threshold at BTS for h/o. Lower threshold used for cells hopping over 6 or more frequencies, 55 if cell is not hopping.

PSSHF
PTIMHF
IBHOSICH
IHOSICH
SCHO
CELLQ

SS penalty applied to a cell to which h/o fails


Duration of penalty PSSHF for handover failure
Flag to enable SDCCH handover inter-BSC
Flag for enabling intra-cell handover on SDCCH
Flag to enable SDCCH handover
Defines if cell is suitable for RPD load regulation

Page 17 of 39

Parameter

Comments

MAXTA

Maximum timing advance permitted before disconnection. Normal cell can work to 63. RBS200 Xrange cell with SPP cards can work to 133 and new RBS2000 Xtended range hardware can work
to 219.

RLINKUP

Radio Link Timeout counter value on the uplink.

RLINKT

Radio link Timeout counter value for MS (D/L)

HPBSTATE

Switch for handover power boost

CHALLOC

2: Non hopping TCH on BCCH is allocated as last preference 1: Non-hopping TCH on BCCH allocated as first preference 0: No preference

EBANDINCLUDED

Decide whether channels in the P-GSM 900 band only or whether also GSM 900 G1 channels are to be considered for handling of the radio features.

MAXCHDATARATE

Defines the maximum channel data rate allowed in the BSC - modem type.

SPEECHVERUSED

Decides if the used speech version shall be placed at the top in the list of allowed speech version at handover.

BSCMC

Identifies if more than one full rate TCH are allowed to be allocated for each MS connection in BSC internal cells.

CMDR

Maximum channel data rate for a cell - modem type

CHAP

Channel allocation profile selection.

SAS

Single slot allocation strategy

NECI

0 = GSM est. causes only, 1 = phase 2 est. causes NEWNAME 1 TO 7 CHAR. EXCEPT ALL * * C F The parameter is used to change the name of a cell.

MC

ON=multiple channels allocations to MS allowed

CHCODING

GPRS Channel coding scheme to be used

GPRSNWMODE

GPRS Network Mode determines if a PBCCH exists in the cell.

GPRSPRIO

Sets the priority between PDCHs and the features Dynamic Half Rate Allocation/Half Rate Packing, Cell Load Sharing and Sub cell Load Distribution

PILTIMER

Time a dynamic PDCH channel can remain idle before being reconfigured to a TCH, EDGE\GPRS Cell = 10.

EGPRSBPCLIMIT

Maximum allowed number of EGPRS timeslots or data connections in the BSC.

ONDEMANDGPHDEV

Number of reserved GPH devices in an RPP that can be used for on-demand PDCH only.

ONDEMANDGPHDV64 On Demand GPH Subdevices (64k).


PSETCHKPERIOD

Periodic check of GPRS primary dedicated channels.

Page 18 of 39

Parameter

Comments

TBFDLLIMIT

The number of simultaneous TBFs for each PDCH is used as TBF downlink limit.

TBFULLIMIT

The number of simultaneous TBFs for each PDCH is used as TBF uplink limit. TDD 1 to 255, OFF OFF B F Ericsson MSC Parameter Only

NACCACT

Activate/Deactivate Network Assisted Cell Change Feature

PDCHPREEMPT
Defines what kind of on-demand PDCHs are possible to pre-empt for the CS traffic:
GPRSSUP

Activates/deactivates GPRS support for a cell

FPDCH

Number of dedicated PDCH in cell.

SCALLOC

Restrict EGPRS/GPRS to a certain subcell when a subcell exists. Set per Dedicated PDCH location.

PDCHALLOC

Allocates PDCH on BCCH frequency first.

PSKONBCCH

Used to disable the use of 8-PSK on the BCCH carrier.

NUMREQCS3CS4BPC

Number of required CS 3/4 BPCs (set per CHGR).

NUMREQEGPRSBPC

Minimum number of required EGPRS BPCs (set per CHGR). CHGR0 = 4, CHGR1 or greater = 0.

TN7BCCH

Allowance of EGPRS or GPRS on TN7 of the BCCH frequency.

GPRSEDAACT

GPRS Extended Dynamic Allocation Activation.

PULSCHEDINT

Persistent uplink PDCH scheduling interval.

DMPSTATE

Dynamic MS power control state.

AMRPCSTATE

Adaptive Multi-Rate (AMR) power control state.

SSDESUL

Desired Signal Strength uplink at BTS

SSDESULAFR

Desired Signal Strength uplink at BTS for AMR FR

SSLENUL

Length of U/L DPC RxLev averaging filter

LCOMPUL
QDESUL
QDESULAFR
QLENUL

How much path loss is compensated for in MS PC algorithm


Desired RxQual at BTS Rx
Desired RxQual at BTS Rx for AMR FR
Length of uplink DPC RxQual averaging filter

Page 19 of 39

Parameter

Comments

QCOMPUL
REGINTUL

Weighting of RxQual compensation in MS DPC


Uplink or MS Power Control Regulation interval

DTXFUL

No. of meas. reports in new cell before FULL meas.

STEPLIMDL
ALPHA

When on the step size of BTS PC is limited to 2 dB per SACCH


Path loss compensation for GPRS power control

GAMMA

Gives target value for the received signal at the BTS (PS Specific).

AMRPCSTATE

Adaptive Multi-Rate (AMR) power control state.

UPDWNRATIO
DBPSTATE

Ratio of up to down regulation speed of power control


Dynamic BSC power control state.

SDCCHREG
SSDESDL

Controls whether D/L DPC used on SDCCH


Downlink desired signal strength at MS

SSDESDLAFR

Downlink desired signal strength at MS for AMR FR

REGINTDL

Downlink Power control regulation interval/period

SSLENDL

Length of Signal Strength averaging filter D/L DPC

LCOMPDL
QDESDL
QDESDLAFR
QCOMPDL
QLENDL

SS path loss compensation in DL


Desired Quality in DL
Desired Quality in DL for AMR FR
Quality path loss compensation in DL
Length of RxQual averaging period for D/L DPC

BSPWRMIN
DTXD
DTXU
HOP

Minimum DL dynamic power level


Enable/disable of downlink DTX
MS Discontinuous Transmission (DTX) control (u/l), 0 = may use; 1 = shall use, 2 = shall not use DTX
Frequency hopping status, OFF for CHGR=0,ON for GHGR=1

HSN
FHOP

The hopping sequence number


Specifies Base Band or SYnthesized frequency hopping

COMB

Defines which combiner type is used for frequency hopping

CONFMD

Defines configuration method impact

MAIO

Hopping sequence number.

Page 20 of 39

Parameter

Comments

IHO
TMAXIHO
TIHO
MAXIHO
QOFFSETUL

Flag enabling intra-cell handover on a sub-cell, required if Frequency Hopping active.


Maximum time between intra-cell handovers to consider them as consecutive.
Time for which intra-cell h/o inhibited
Maximum number of consecutive intra-cell handovers allowed. For OL / UL cells it must always be less than the no of CHGR in the subcell
Offset FQSS function along RxQual axis (uplink) ; -5 Hopping Layer, -14 BCCH Layer

QOFFSETULAFR

Offset FQSS function, RxQual axis (uplink) for AMR FR

QOFFSETDL

Offset FQSS function along RxQual axis (downlink) ; -5 Hopping Layer, -14 BCCH Layer

QOFFSETDLAFR

Offset FQSS function, RxQual axis (downlink) for AMR FR

SSOFFSETUL
SSOFFSETULAFR
SSOFFSETDL
SSOFFSETDLAFR
ASSOC
IBHOASS
AW
CAND
AWOFFSET
SCLDTIMEINT

Offset FQSS function along RxLev axis (uplink)


Offset FQSS function along RxLev axis (uplink), for AMR FR
Offset FQSS function along RxLev axis (downlink)
Offset FQSS function along RxLev axis (downlink) for AMR FR
Flag to enable assignment to another cell
Flag to enable assignment to another cell inter-BSC
Flag to enable assignment to worse cells from a cell
Candidate type.
Assignment to worse cell negative hysteresis
Time interval for checking the level of underlaid sub cell idle TCH for cells active for Sub cell Load Distribution.

SCLD

Subcell load distribution

SCLDLL

Subcell Load Distribution Lower Limit.

SCLDUL

Subcell Load Distribution Upper Limit.

LOL

Path loss threshold. S-BCCH cell type = (EIRP+85), if data on BCCH set to LOL=0.

LOLHYST

Hysteresis for path loss.

TAOL

Timing advance threshold. S-BCCH cell type = 61.

TAOLHYST

Hysteresis for timing advance.

HCSBANDHYST
THO
NHO
HCSBAND
HCSBANDTHR

Signal Strength hysteresis for the HCSBAND threshold.


Time int for measuring NHO to determine if MS is fast moving
Number of HO during THO that are allowed before MS is considered fast moving
Hierarchical Cell Structure band.
The signal strength threshold prioritizes cells within a HCSBAND.

Page 21 of 39

Parameter

Comments

LAYER

Assigns cell to HCS layer. Recommend GSM1900 less than GSM800.

LAYERTHR

Signal level threshold applying to that cell. (D-BCCH cell: 85 - 1900MHz, 95 - 850MHz)

LAYERHYST
PSSTEMP
PTIMTEMP
FASTMSREG
XRANGE
MBCCHNO

Hysteresis applied to the cell's Signal Threshold


Size of temp. penalty on meas. from new n-cells
Time of temp. penalty on meas. From new n-cells
ON=Fast moving MS handling on
Whether cell is defined as an extended range cell
Absolute RF channel number for measurement on BCCH.

ICMSTATE

ICM enable/disabled or used for statistical purpose

INTAVE

Interference Averaging period

LSSTATE

Cell Load Sharing at the BSC level

CLSTIMEINTERVAL
CLSSTATE

Time interval in which TCH activity is checked when load sharing


Cell load sharing active. inactive for a cell

CLSACC
CLSLEVEL
CLSRAMP
HOCLSACC
RHYST
CLMRKMSG
MODE

% idle channel free level, below which no shredded call is accepted by target cell
% idle channel free level at which shedding of calls is started
Time interval in which hysteresis is ramped down
Enable/disable acceptance of incoming h/o due to Load Sharing
Hysteresis reduction factor (how much of hysteresis zone is used for call shedding)
Indicates how the Classmark Change message will be handled if it is received as a first RR message from the Mobile Station
The BSC band operation mode identifier.

GSYSTYPE

Specifies the system type for the BSC. Mixed allows both 850MHz and 1900MHz within the same BSC.

CSYSTYPE

Specifies the system type for the cell.

MBCR
DCAHANDOVER
DCASTATE

No. of n-cells from each band reported in measurement report: different between dual band and single band markets.
Differential Channel Allocation is not used
Differential channel allocation switch.

EMERGPRL
STATSINT

Priority level for emergency calls.


Differential channel allocation statistics collection time interval.

CHTYPE
CHRATE
PHSTATE

Differential Channel Allocation is not used


Differential Channel Allocation is not used

Indicates if Pre-emption Handling is to be initiated.

Page 22 of 39

Parameter

Comments

ACSTATE

Enable/disable of dynamic change of SDCCH channels

SLEVEL

Remaining SDCCH sub channels when attempt to increase number will take place

STIME

Min time before dynamic SDCCH is reconfigured back to TCH

COEXUMTS
Support for Coexistence of GSM and UMTS
COEXUMTSINT
Time interval between traffic load checking.
UMFI
UTRAN Measurement Frequency Information for cell reselection in GSM Idle Mode and GPRS/EGPRS Ready and Standby states
FDDQMIN
Defines the minimum threshold for the "quality" measure Ec/No for cell reselection to UTRAN cells.
FDDQOFF
Defines the inter-system cell reselection offset to UTRAN cells.
SPRIO
Indicates if 3G cells may be searched when BSIC decoding is required.
QSI
Indicates the threshold to start UTRAN FDD measurements in Idle mode and Stand-by and Ready states.
ISHOLEV
Inter system handover evaluations start. % of TCH idle.
FDDMRR
Defines how many measured neighbouring UTRAN cells should be included in measurement reports
QSC
Indicates the threshold to start UTRAN FDD measurements in Active mode. 15 = Never
QSCI
UTRAN measurements after entering active mode, before reading the first QSC. 0 = Use QSI threshold, 1 = always.
CELLR

Related cell designation.

SET
MODE

AMR parameters SET, MODE, HYST, and THR to be trialed


1 = 4.75 Kbps (HR and FR)
2 = 5.15 Kbps (HR and FR)
3 = 5.90 Kbps (HR and FR)
4 = 6.70 Kbps (HR and FR)
5 = 7.40 Kbps (HR and FR)
6 = 7.95 Kbps (HR only)
7 = 10.2 Kbps (HR only)
8 = 12.2 Kbps (HR only)

HYST
THR
AMRFRSUPPORT
AMRHRSUPPORT
LQCACT

Hysteresis for changing the codec mode


Threshold for changing the codec mode
Adaptive Full-Rate feature switch.
Adaptive Half-Rate feature switch.
Used to switch LQC on or off on the downlink and uplink

Page 23 of 39

Parameter

Comments

LQCIR
LQCDEFAULTMCSDL
LQCDEFAULTMCSUL
LQCHIGHMCS
LQCUNACK
LA
CHCSDL
PCUQOS

Used to control which mode LQC shall run TBFs using RLC acknowledged mode.
Controls which DL MCS is used when LQC is switched OFF.
Used to control the MCS for uplink transfers
Used to define the highest allowed MCS level to be used
Used to shift the selection of MCS to a more robust MCS level when RLC unacknowledged mode is used.
Used to switch GPRS Link Adaptation ON and OFF
If GPRS Link Adaptation is switched on, then used as initial coding scheme for downlink
Activates or deactivates support for 3GPP TS 08.18 Packet Flow Management (PFM) in the PCU.

THPMBRFACTOR

To what degree should MBR be taken into account for scheduling interactive user.

QOSTHP1

Weight to use for interactive PFCs of THP1

QOSTHP2

Weight to use for interactive PFCs of THP2

CONVSTREAMTHP

Defines which THP to use if the requested traffic class is not available.

GPRSQOS

IRC

Activates the Interference Rejection Combining feature

FBOFFS
BAND

Offset between BCCH frequency band group and non- BCCH frequency band group.
Frequency band supported by the transmitter/receiver

DLDELAY

Defines the time a downlink TBF is kept alive after there is no more user data to send in downlink.

ESDELAY

Defines the time a downlink TBF is kept alive after it has been automatically set up by the initiation of an uplink TBF.

TFILIMIT

Defines the minimum number of TFIs available for a PSET before ESDELAY or DLDELAY will initiate.

ULDELAY

Defines the time an Uplink TBF is kept alive.

USFLIMIT

Specifies the lower limit for available USFs before uplink TBF is released.

DHA
DMQB

Dynamic AMR Half Rate Allocation feature state.


Defines whether or not Dynamic AMR Half Rate (HR) to AMR Full Rate (FR) Mode Adaptation due to bad quality is active.

DMQBAMR

Defines a threshold to initiate a change from HR to FR.

DMQG

Defines whether or not Dynamic AMR Full Rate (FR) to AMR Half Rate (HR) Mode Adaptation quality evaluation is active.

DMQGAMR

Defines a threshold to initiate a change from FR to HR.

Page 24 of 39

Parameter

Comments

DMSUPP

Dynamic FR/HR Mode Adaptation feature state.

DMTHAMR

Dynamic FR to HR Mode Adaptation threshold for AMR capable mobile.

DTHAMR

Defines a threshold to initiate AMR HR at call allocation.

ABISALLOC
ALLOCPREF
ANT
ANTA
ANTB
BTDM
CBCHD
CRT
CTEI
DMQBNAMR
DMQGNAMR
DMTHNAMR

Controls the way Abis paths are allocated to the TCHs capable of 64kbps, set per TG.
DTM connection shall be allocated with maximum speech quality considerations or with packing considerations prefer TCH/HR.
Name of antenna connected to transmitter
Name of antenna A connected to receiver
Name of antenna B connected to receiver
Base time duration of implicit detach of a mobile subscriber by the network, Ericsson MSC Only.
Shall PSI8 be transferred on the PBCCH or not.
Channel Rate and Type, Ericsson MSC Only.
TGC
Non-AMR trigger from HR to FR channel
Non-AMR trigger from FR to HR channel
HR Packing for Non-AMR Dual Rate capable MS units

DTCB

Distance to cell border threshold between active channel and neighboring BCCHs.

DTCBHYST

Hysteresis for the DTCB criterion.

DTCBSC
DTHNAMR
EGPRSBPCLIMIT

Defines if the DTCB criterion is taken into consideration during subcell changes (1), or not (0)
HR Packing at initial call set-up for Non-AMR Dual Rate capable MS units.
Maximum allowed number of EGPRS timeslots or data connections in the BSC.

FBCHALLOC
FLEX64KGPRS
GTDM
HNDBEFOREBANSWM
HNDRELCHINTRAM
HNDSDCCHINTI
HNDSDCCHINTOM
HNDSDCCHM
HNDSDCCHTCHM
HNDTGSOPINTRA
LATAUSED
LIMIT1
LIMIT2
LIMIT3
LIMIT4
LISTTYPE
MAXLAPDM

0 - No selection preference; 1 - Select channels in BCCH frequency band first; 2 - Select channels in BCCH frequency band last. (Tri-Band Usage Only)
Abis resource allocation handling for EGPRS capable channel.
Guard time duration, Ericsson MSC Only.
Indicates if an inter-MSC handover is allowed on traffic channels before answer from B-subscriber, Ericsson MSC Only.
Defines the release of the original channel after expiration of the timer TIMHNDCMDINTRAM for handover time supervision in intra-MSC inter-BSC handover, Ericsson MSC Only.
Incoming inter-MSC handover on signaling channels in non-anchor MSC, Ericsson MSC Only.
Determines if outgoing inter-MSC handover is allowed on signaling channels in anchor MSC, Ericsson MSC Only.
Determines if intra-MSC inter-BSC handover is allowed on signaling channels, Ericsson MSC Only.
If intra-MSC inter-BSC handover is allowed from signaling to traffic channel, Ericsson MSC Only.
Time supervision of switching moment of the group switch (GS) in the MSC at intra-MSC inter-BSC handover.Ericsson MSCOnly
Defines the usage of LATA administration, Ericsson MSC Only.
Boundary between interference bands 1&2, Alt. Settings: 3 for macro-cells. 6 for micro cells
Boundary between interference bands 2&3, Alt. Settings: 5 for macro cells, 10 for micro cells
Boundary between interference bands 3&4, Alt. Settings: 8 for macro sells, 14 fro micro cells
Boundary between interference bands 4&5, Alt. Settings: 10 for macro cells, 18 for micro cells
This parameter identifies which type of list the chosen frequencies will be on.
DTM, to control the maximum length of the GPRS signaling messages sent on the FACCH.

Page 25 of 39

Parameter

Comments

MAXNOSDCCHTRX
MAXSBLK
MAXSMSG
MBCRAC
MCCSUPPORT
MPDCH
MPWR
MSQUEUING

Maximum number of SDCCH/8 per TRX


The maximum value the BS_PBCCH_BLKS is allowed to have reserved radio blocks to be used for the PBCCH.
The maximum number of PSI messages that preferably shall be scheduled on one PBCCH block.
Defines the method that GPRS/EGPRS MS frequency band capabilities are handled.
Mobile Crosstalk Control support in the transcoders
Whether or not a MPDCH shall be allocated in a PDCCH.
Maximum Transmitter Power
Wireless Priority Service - MS Queuing, Off or On

NDIST

Distance to cell border additional threshold.

NNCELLS
PAGLATA
PAGNUMBERLA
PAGREP1LA
PAGREPCT1LA
PAGREPGLOB
PAGTIMEFRST1LA
PAGTIMEFRSTGLOB
PAGTIMEREP1LA
PAGTIMEREPGLOB
PAGTIMEREPLATA
PDCHPREEMPT
PILTIMERFLEX
PRACHBLK
PRIMPLIM
PSCVL
QLENGTH
QOSMAPPING
RESLIMIT
ROMTBIPADDRLSW
ROMTBIPADDRMSW
RXD
SECPAGEPATH
SPDCH
SYNCSRC
SYSTYPE
TEI
TFMODE
TIMHNDCMDINTRAM
TIMPAGINGM
TRAFBLK
TRXC
TXID

Number of strongest neighboring BCCHs for DTCB criterion.


Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Defines what kind of on-demand PDCHs are possible to pre-empt for the CS traffic:
Packet idle list timer factor for PDCHs with flexible ABIS.
The minimum number of reserved radio block periods for PRACH.
The maximum number of dedicated and semi-dedicated PDCHs allowed in the primary PSET.
Ericsson MSC Parameter Only
Wireless Priority Service - Maximum Queue Length
Changes or deactivates support for QoS mapping.
Wireless Priority Service - Channel Resource Limit
Low part of the BSC Internet Protocol address for ROMT, if R-OMT active recommended value ignored.
High part of the BSC Internet Protocol address for ROMT, if R-OMT active recommended value ignored.
Defines the use of receiver diversity in a given TRX SAS QUALITY, MAIO, MULTI QUALITY QUALITY C F Single slot allocation strategy.
Ericsson MSC Parameter Only *SET FR3, FR4, HR3, HR4 - - B F Adaptive Multi Rate (AMR) codec set changed by the operator.
Defines the number of semi-dedicated PDCHs.
F Timing function synchronization source in the BSC, must match BTS.
System Type
Terminal Endpoint Identifier. RBS 2000 and RBS 200 series respectively.
Timing Function Synchronization Mode.
Describes the time between the HANDOVER COMMAND and HANDOVER COMPLETE messages in intra-MSC inter-BSC handover, Ericsson MSC Only.
Ericsson MSC Parameter Only
The number of blocks within a multiframe where neither paging nor PSI messages shall appear.
TRXC can be regarded as the HW position for the element that is addressed by the parameter TEI.
The transmitter ID.

Page 26 of 39

Parameter
DL
UL
BSPWRB
CELL
RSITE
TG

CGI
MCC
MNC
LAC
CI
NCC
BCC
BCCHNO
BCCHTYPE
AGBLK
MFRMS
FNOFFSET
ECSC
SCTYPE
MNCDIGITHAND
TSC
MSTXPWR
BSPWRT
CHGR
STATE
NUMREQBPC

Page 27 of 39

Parameter
DCHNO
BCCD
SDCCH

CCHPOS
TN
CBCH
TRADROPLEVEL
TRADROPNOTRAF
CELLR
CTYPE
RELATION
CS
ACCMIN
CCHPWR
CRH
NCCPERM
SIMSG

MSGDIST

CB
CBQ

Page 28 of 39

Parameter
ACC
MAXRET
TX
ATT
T3212

CRO
TO
PT
FASTASSIGN
NOOFPHYSINFOMSG
TIMER3105
EVALTYPE
TINIT
TALLOC
TURGEN
TAAVELEN
SSEVALSD
QEVALSD
SSEVALSI
QEVALSI
SSLENSD
QLENSD
SSLENSI
QLENSI
SSRAMPSD
SSRAMPSI
MISSNM
BSPWR
MSRXMIN
BSRXMIN

Page 29 of 39

Parameter
MSRXSUFF
BSRXSUFF
BSTXPWR
KHYST
LHYST
TRHYST
KOFFSET
LOFFSET
TROFFSET
HIHYST
LOHYST
HYSTSEP
OFFSET
BADQDL
BADQUL
LOWSSDL
LOWSSUL
TALIM
PSSBQ
PSSTA
PTIMBQ
PTIMTA
BQOFFSET
BQOFFSETAFR
EXTPEN
QLIMDL
QLIMDLAFR
QLIMUL
QLIMULAFR
PSSHF
PTIMHF
IBHOSICH
IHOSICH
SCHO
CELLQ

Page 30 of 39

Parameter
MAXTA
RLINKUP
RLINKT
HPBSTATE
CHALLOC
EBANDINCLUDED
MAXCHDATARATE
SPEECHVERUSED
BSCMC
CMDR
CHAP

SAS
NECI
MC
CHCODING
GPRSNWMODE
GPRSPRIO
PILTIMER
EGPRSBPCLIMIT
ONDEMANDGPHDEV
ONDEMANDGPHDV64
PSETCHKPERIOD

Page 31 of 39

Parameter
TBFDLLIMIT
TBFULLIMIT
NACCACT
PDCHPREEMPT
GPRSSUP
FPDCH
SCALLOC

PDCHALLOC
PSKONBCCH
NUMREQCS3CS4BPC
NUMREQEGPRSBPC
TN7BCCH
GPRSEDAACT
PULSCHEDINT
DMPSTATE
AMRPCSTATE
SSDESUL
SSDESULAFR
SSLENUL
LCOMPUL
QDESUL
QDESULAFR
QLENUL

Page 32 of 39

Parameter
QCOMPUL
REGINTUL
DTXFUL
STEPLIMDL
ALPHA
GAMMA
AMRPCSTATE
UPDWNRATIO
DBPSTATE
SDCCHREG
SSDESDL
SSDESDLAFR
REGINTDL
SSLENDL
LCOMPDL
QDESDL
QDESDLAFR
QCOMPDL
QLENDL
BSPWRMIN
DTXD
DTXU
HOP
HSN
FHOP
COMB

CONFMD

MAIO

Page 33 of 39

Parameter
IHO
TMAXIHO
TIHO
MAXIHO
QOFFSETUL
QOFFSETULAFR
QOFFSETDL
QOFFSETDLAFR
SSOFFSETUL
SSOFFSETULAFR
SSOFFSETDL
SSOFFSETDLAFR
ASSOC
IBHOASS
AW
CAND
AWOFFSET
SCLDTIMEINT
SCLD

SCLDLL
SCLDUL
LOL
LOLHYST
TAOL
TAOLHYST
HCSBANDHYST
THO
NHO
HCSBAND
HCSBANDTHR

Page 34 of 39

Parameter
LAYER
LAYERTHR
LAYERHYST
PSSTEMP
PTIMTEMP
FASTMSREG
XRANGE
MBCCHNO
ICMSTATE
INTAVE
LSSTATE
CLSTIMEINTERVAL
CLSSTATE
CLSACC
CLSLEVEL
CLSRAMP
HOCLSACC
RHYST
CLMRKMSG
MODE
GSYSTYPE
CSYSTYPE
MBCR
DCAHANDOVER
DCASTATE
EMERGPRL
STATSINT
CHTYPE
CHRATE
PHSTATE

Page 35 of 39

Parameter
ACSTATE
SLEVEL
STIME
COEXUMTS
COEXUMTSINT
UMFI

FDDQMIN
FDDQOFF
SPRIO
QSI
ISHOLEV
FDDMRR
QSC
QSCI
CELLR
SET
MODE

HYST
THR
AMRFRSUPPORT
AMRHRSUPPORT
LQCACT

Page 36 of 39

Parameter
LQCIR
LQCDEFAULTMCSDL
LQCDEFAULTMCSUL
LQCHIGHMCS
LQCUNACK
LA
CHCSDL
PCUQOS
THPMBRFACTOR
QOSTHP1
QOSTHP2
CONVSTREAMTHP
GPRSQOS

IRC
FBOFFS
BAND
DLDELAY
ESDELAY
TFILIMIT
ULDELAY
USFLIMIT
DHA
DMQB
DMQBAMR
DMQG
DMQGAMR

Page 37 of 39

Parameter
DMSUPP
DMTHAMR
DTHAMR
ABISALLOC
ALLOCPREF
ANT
ANTA
ANTB
BTDM
CBCHD
CRT
CTEI
DMQBNAMR
DMQGNAMR
DMTHNAMR

Application Terminal Endpoint Identifier

DTCB
DTCBHYST
DTCBSC
DTHNAMR
EGPRSBPCLIMIT
FBCHALLOC
FLEX64KGPRS
GTDM
HNDBEFOREBANSWM
HNDRELCHINTRAM
HNDSDCCHINTI
HNDSDCCHINTOM
HNDSDCCHM
HNDSDCCHTCHM
HNDTGSOPINTRA
LATAUSED
LIMIT1
LIMIT2
LIMIT3
LIMIT4
LISTTYPE
MAXLAPDM

Page 38 of 39

Parameter

MAXNOSDCCHTRX
MAXSBLK
MAXSMSG
MBCRAC
MCCSUPPORT
MPDCH
MPWR
MSQUEUING
NDIST
NNCELLS
PAGLATA
PAGNUMBERLA
PAGREP1LA
PAGREPCT1LA
PAGREPGLOB
PAGTIMEFRST1LA
PAGTIMEFRSTGLOB
PAGTIMEREP1LA
PAGTIMEREPGLOB
PAGTIMEREPLATA
PDCHPREEMPT
PILTIMERFLEX
PRACHBLK
PRIMPLIM
PSCVL
QLENGTH
QOSMAPPING
RESLIMIT
ROMTBIPADDRLSW
ROMTBIPADDRMSW
RXD
SECPAGEPATH
SPDCH
SYNCSRC
SYSTYPE
TEI
TFMODE
TIMHNDCMDINTRAM
TIMPAGINGM
TRAFBLK
TRXC
TXID

Page 39 of 39

S-ar putea să vă placă și