Instruction Manual
3. All expenses incurred during the return product.
process is the sole responsibility of the user. 2. This unit is subject to change without prior
can be displayed. ● First Timer to utilize O2 sensor
(shipping charges, etc…) notice ●Displays A/F ratio as RICH or voltage when calculating after
4. The following claims will not be honored 3. We will not reissue this manual. Please keep
Thank you for purchasing this product.. Please read all of this manual to ● Unit is not returned with an RA# this manual in a safe place. LEAN via 2 LED idling time. Compared to timers
● Units that have been modified or tampered
ensure proper usage. Also, please keep this manual in a safe place for fu- ●Displays battery voltage .Also that only use vehicle speed and
with. [To the dealer] Double Sided Tape…1
ture reference. Be sure to provide this manual to the next user in case of warns of extremely LOW battery RPM, this TIMER can set the Control Unit…1 Relay Unit…1 Zip Tie…2
● Scratches and paint discoloration from Be sure to note customer information, date of
ownership change. normal usage. purchase, and location. This information will be
voltages。 most accurate after idling time
● Damage from shipping or abuse. necessary in the event the unit is returned to
● Damage incurred from other products the shop for evaluation. ●16 way adjustment of after idle possible. AT3000-0000
Part Code 405-A011 ● Any other cause that canot be proven after ●Automatic after idling feature. In
proper examination.
Purpose Engine After-Idling unit order to ensure the most opti- Fitting…1 Splice…2 Electro-Tap…1 Serial Number…1
5. This warranty is subject to change at any
Application DC12V Body Ground Autos mum after idling setting from the
Warranty
All APEX products are shipped in pristine condition. In the event that the unit does not properly, please fill
■Vehicles that cannot use the A/F function out this card and return the unit to the dealer of purchase. Do not send the unit directly to the manufacturer.
・Titanium type O2 sensor vehicles Vehicle Specific Chart…1 Instruction Manual…1
(BNR32 Skyline GT-R,(R)PS13 Silvia/180SX(‘91.1~‘93.10)etc)
Warr. Terms 30 days from purchase date 5 Installation Procedures
Product
■Vehicles that cannot utilize the auto idling feature Purchase Date ■Installation Diagram
・Vehicles that cannot use the A/F function ※Please place product sticker here
Please
お願い Never pull hard on any connectors or harnesses.
●Checking the Safety Switch(Parking Brake Switch)
Do not use this product for Never operate this unit Do not leave the engine Remote Door Lock Systems Be sure to turn AUTO Be sure to test unit opera-
any other purpose than the while driving. running in closed garages
1. Pull the parking brake, start down.
and Adjustable Steering LIGHT systems OFF. tion and safety wire opera-
one listed in this manual. or sealed areas. Columns may not function Failure to do so may cause tion after installation. the engine, and make sure 4. Release the parking brake
We are not responsible for Failure to do so may lead to
Failure to do so may lead
to exhaust fume poisoning.
properly after installation of the lights to stay on after
the engine has been shut
●Mounting the Control Unit the IG key is ON. during the countdown pro-
this unit.
any damages or injuries accidents. off. This may kill the 1. Use the included double does not interfere with 2. Set the Timer to a random cess.
incurred from improper battery. setting above 30 seconds. 5. Be sure the engine shuts
usage of this product. sided tape to mount. driving. Connect to relay.
2. Mount in a location that 3. Reconnect battery. 3. Turn the IG key OFF and completely off.
activate the Timer count-
6 Operation
To turn OFF the Auto Timer
Part Names and Functions Setting the Minimum Battery Voltage Warning A/F value, O2 Sensor Voltage Setting
This product contains various A/F and O2 Sensor values. Turn the TIMER OFF when not in use.
●To activate Setting Mode… The values range between A/F value(1)-O2 sensor voltage (1)
While battery voltage is being displayed, ●To turn the TIMER OFF…
……A/F value(8)-O2 sensor voltage(8)
During display mode,
【Hold the knob to the RIGHT】 Please use the chart below when changing the setting A/F -O2
【Hold the knob to the LEFT】
will flash indicating that the setting sensor voltage data Table1 A/Fvalue-O sensor voltage data chart
2
The 7 segment LED will read『OFF』shutting OFF the unit
mode has been activated A/F 10.0 12.0 14.0 14.6 15.0 16.0 18.0 20.0
7 Segment LED LED 4 Way Switch ●After setting…
O2Sensor V 960 940 820 450 010 006 004 002
【Hold the knob to the LEFT】
This will return to the Display Mode
Glossary of terms:
【Hold】Tilt knob over 0.5 sec in specified direction
Setting the A/F Value
●To turn the TIMER back ON…
【Activate】Tilt knob less than 0.5 sec in specified direction ●To enter the setting mode… While the unit is OFF,
How to Set While displaying A/F 【Hold the knob to the LEFT】
【Activate the knob either UP or
DOWN】 【Hold the knob to the RIGHT】 Or,
Set the minimum warning battery Will flash indicating setting mode 【Hold the knob to the RIGHT】
voltage
Display Choose between 10.0V~15.0V in
0.1V increments ●How to set…
Turning the IG key ON will activate the display mode. The A/F andO2 sensor voltage will alternately display
(Power must be on) (A/F will display longer)
Contents may be checked through flashing lights Setting the After Idling Time Input the A/F data corresponding to the displayed O2 sensor
voltage
●To activate Setting Mode… The O2 sensor data can be changed in the next section Other…
Display Parameters While After Idling is being displayed, ●Once setting is complete…
● A/F ratio 【Hold the knob to the RIGHT】 【Hold knob to the LEFT】
●To turn engine OFF during a TIMER countdown…
● O2 Sensor Voltage will flash indicating that the setting During countdown,
● Battery Voltage mode has been activated
●For Calculation Mode…(Manual or Auto) 【Hold the knob to the LEFT】
● After Idling time Procedure
After Idling times can be selected through Manual or Auto modes. Or,
A/F value(1) A/F value(8) 【Hold the knob to the RIGHT】
To toggle between Manual or Auto mode,
【Hold the knob to the RIGHT】 【Tilting knob to RIGHT or
This will turn the TIMER OFF thereby shutting the engine OFF.
Choose Display Parameter LEFT】will change the range (Ignition key must be removed)
of A/F , O2 data (see Table1)
●After setting…
To toggle between A/F ratio,O2 Sensor Voltage, Battery Voltage, After ●Changing the after idling time during TIMER countdown…
【Hold the knob to the LEFT】
Idling Time, A/F and O2 will alternately display During TIMER countdown,
This will return to the Display Mode O2 sensor V (1) (A/F will display longer) O2 sensor V(8)
【Activate the knob either UP or DOWN】
【Tilt knob UP】
A/F Value
Display Selection to increase time
How to Set 【Tilting knob either UP or 【Tilt knob DOWN】
Select Calculation Mode DOWN】will allow setting of to decrease time.
【Hold knob to the RIGHT】 desired A/F value.
Hold
After Idle O2 Sensor
O2 Sensor Voltage Setting
Time Voltage
(V)
About the A/F ratio values…
Manual Mode Auto Mode ●To enter the setting mode…
While displaying O2sensor voltage(mV) This unit calculates a theoretical A/F
If display looks like below, If display looks like below,
The unit is in【Manual Mode】 The unit is in【Auto Mode】。 【Hold the knob to the RIGHT】 value based upon the factory installed
Battery
A/FRatio Will flash indicating setting mode O2 sensor .O 2 sensor voltage output
Voltage
(V) characteristics follow the chart to the
●How to set… right, where rich conditions produce a
The O2 sensor voltage and A/F will alternately display near 1V signal while a lean condition
(O2 will display longer) produces a near 0.1 V signal. Although
【Activate the knob either UP or “Minute” “Second”
MAX After Auto Calcula- MIN After Idle
Input the O2 sensor voltage corresponding to the displayed A/F the A/F value is calculated off of this
Idle Value tion Rate Value
DOWN】 data O2 sensor voltage, factors such as ex-
0sec This sets the This sets the This sets the
10 sec maximum auto calcula- minimum The A/F sensor data can be changed in the previous section haust temperature prevent the O2 sen-
20 sec amount of tion rate of amount of ●Once setting is complete… sor from producing a stable and con-
30 sec idle time. the Timer. idle time.
40 sec
The vehicle 【Hold the knob to the LEFT】 stant reading. Please use this feature
50 sec
1 min
Value de- There are will always only to determine rich or lean conditions.
notes MIN- three idle for at
1 min30 sec Also, different O2 sensors will produce
Set the unit 2 min UTES. Please
choose
modes, least
amount
this
of different voltage readings.
2 min30 sec
3 min between 1
“H” High
“n”Normal time. Procedure
While in display mode and while the parking brake is activated, 4 min min~ 8 min Choose O2 sensor V(1)
“L” Low O2 sensor V (8)
5 min between
【Hold the knob to the RIGHT】This will activate the Setting mode 6 min 0~60 seconds If the O2 sensor has not warmed up
8 min in 10 second 【Tilting knob to RIGHT or enough,
for that parameter. 10 min increments. LEFT】will change the range
will flash red and green.
The LED will flash to confirm setting mode. of A/F , O2 data (see Table1)
Once the O2 sensor warms up, the display
During Setting Mode【Hold the knob to the LEFT】to end. mode will initiate.
【Tilt the knob either to the
【Activate the knob either UP RIGHT or LEFT】to select pa- O2 and A/F will alternately display
or DOWN】to select After Idling A/F value (1) (O2 will display longer) A/F value (8)
rameters When the A/F reaches over 10.0,
Parameters that can be Set Times
● A/F ratio according to O2Sensor Voltage Range: 0 sec~10 min in 16 【Tilt the knob either UP or
O2 sensor voltage(mV) will flash red.
increments DOWN】to change values
● O2 Sensor Voltage according to A/F ratio
【Tilting knob either UP or
● Minimum Battery Voltage Warning DOWN】will allow setting of When the A/F goes under 20.0
Select 【Hold knob to the LEFT】to return to
● After Idling Time desired O2 value.
Display Mode will flash green.