Sunteți pe pagina 1din 348

ISOGEN Option Switches

Reference Guide

ALIAS SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE OR USE OF THIS MATERIAL.
It is the policy of Alias Limited to enforce any and all rights relating to protection of this information. The information contained in this
manual is proprietary in nature and may not be reproduced, copied or divulged in whole or in part without the prior written consent of Alias
Limited. This manual has been provided pursuant to the terms of a contract or confidentiality agreement. Unauthorised distribution or
disclosure of its contents is a violation of that contract or agreement and persons doing so may be liable for penalties as provided by law.
Copyright 1991-2009 Alias Limited. All Rights Reserved.
Alias Limited
1 Stuart Road, Manor Park
Runcorn, Cheshire
WA7 1TS
United Kingdom
Telephone:
Fax:
Email:

+44 (0) 1928 579311


+44 (0) 1928 579389
info@alias.ltd.uk

I-Sketch, I-Convert, I-Export, I-View, I-View CAD, I-Data Integrator, I-Data Estimator, I-Tools, I-Run, I-Serve,
SPOOLGEN and ISOGEN are registered trademarks of Alias Limited.
All other trademarks are the property of their respective owners.

Option Switches Reference Guide

Option Switches listed by number:


Click on an Option Switch name to access its information.

Option Switches listed by number:

1. Plotfile length 1
2. Cut piece numbering/list type 2
3. Drawing trim marks 5
4. Drawing text size 6
5. Co-ordinates - Connection/connectivity 8
6. Date output 9
7. Pipeline splitting - User control 10
8. Dimension line standout 12
9. Dimension form 15
10. Drawing margin - Left 18
11. Drawing margin - Right 19
12. Drawing margin - Top 20
13. Drawing margin - Bottom 21
14. Drawing size - Standard postscript plotter size 22
15. Drawing size - Height 24
16. Drawing size - Width 25
17. Flow arrows - Components 26
18. Drawing frame - Program standard 27
19. Sloping pipeline indication method 28
20. Sloping pipeline indication limit 31
21. Isometric type 32
22. Cut piece add-on allowance 34
23. Material list - Controls and File type 35
24. Material list - Pipeline/drawing and Pipeline length units 37
25. Material list and Title block- position 39
26. Material list - Descriptions 40
27. Material list - Text size 41
28. Material list - Item code length 42
29. Material list - Line spacing 43
30. Material list - Continuation method 44
31. Drawing output - File/screen 46
32. Drawing output - scaling 47
33. Revision/detailed marker 48
34. Drawing output - Picture scale 49
35. Drawing - Reserved areas 50
36. Drawing output - Stacking value 51
37. Drawing output - Stacking orientation 52
38. Pipeline splitting - Automatic 53
Switches
by name

ALIAS

39. Spool piece identifiers 55


40. Pipe supports 58
41. Bore/Dimension/Weight Control 61
42. Drawing viewpoint 65
43. Pipe wastage factor - Area 1 66
44. Pipe wastage factor - Area 2 67
45. Pipe wastage factor - Area 3 68
46. Pipe wastage factor - Area 4 69
47. Pipe wastage factor - Area 5 70
48. Pipe wastage factor - Area 6 71
49. Pipe wastage factor - Area 7 72
50. Pipe wastage factor - Area 8 73
51. Pipe wastage factor - Area 9 74
52. Equipment trim drawings 75
53. Weld numbering 77
54. Weld plotting 80
55. Program messages - Run information 82
56. Program messages - Isodat 84
57. Program messages - Isoplot 85
58. Clear screen 86
59. Instrument identification 87
60. Component tagging 88
61. Insulation indication 89
62. Tracing indication 90
63. Printed output - Page length 91
64. Pipe support identification 92
65. Bolting units 94
66. Co-ordinates - Supplementary 96
67. Sloping pipeline - 3D skew depiction 99
68. Sloping pipeline - Vertical branches 101
69. Terminal type identification 102
70. Skew indication - Branches 105
71. Plotfile format 106
72. Leading Zeros 109
73. Material part number enclosure style 110
74. Material list accumulation control 112
75. Weld number - Enclosure and prefix 114
76. Material part number enclosure shape 117
77. Weld number allocation at slip-on flanges and reinforcement pads
78. Support Weld Number Enclosures 121
79. Site Assembly Identification 124
80. Dimensions - To valve centres 126
81. Dimensions - Branches 128
82. C of G / Weight output 130
83. Site Welds Associated with Spools 132
84. Curved Pipe 133
85. Spare switch 134

119

Switches
by name

ALIAS

86. Spare switch 135


87. Spare switch 136
88. Spare switch 137
89. Spare switch 138
90. Material control - Comdace file contents 139
91. Material control - Comdace file controls 140
92. DXF file units 141
93. Spare switch 142
94. Spare switch 143
95. Component leg length 144
96. Reserved 146
97. Skew depiction - Individual / overall 147
98. Spare switch 148
99. Skew depiction - Style 149
100. Skew depiction - Dimension line standout 151
101. Skew depiction - Triangle hatching 152
102. Skew depiction - Hatching clearance 153
103. Spare switch 154
104. Spare switch 155
105. Spare switch 156
106. Spare switch 157
107. Spare switch 158
108. Pipeline splitting - In tube 159
109. Repeatability file content 160
110. Ghost gaps 162
111. Nozzles - Dotted 163
112. Flow arrows - Pipeline 164
113. Material control - Pipeline identification 165
114. Specification break indication 166
115. Tolerance - Angle offset 167
116. Tolerance - Dimension offset 168
117. Dimension round off 169
118. Dimensions - Overall 170
119. Dimensions / elevations - Vertical 172
120. Tapping - Branch scale 174
121. Tapping - Branch dimensions 175
122. Tapping - Branch co-ordinates 176
123. Instrument ID enclosure 177
124. Flange rotation angles 179
125. Reserved 180
126. Reserved 181
127. Isogen version / run date 182
128. Fab friendly isometrics 183
129. Interactive editing 185
130. Development testing 186
131. Development testing 187
132. Development testing 188

Switches
by name

ALIAS

133. Development testing 189


134. Development testing 190
135. Development testing 191
136. Development testing 192
137. Development testing 193
138. Plotfile - DGN link and ASCII text
139. Development testing 195
140. Development testing 196

Versions
Index

194

336

340

Switches
by name

ALIAS

1.

Plotfile length

Options

ISOGEN
Switch Title

Option Switch No.

PLOTFILE LENGTH

Description

This Option Switch is used to control the physical length of the Plotfile that
is generated by the ISOGEN program.
It is only necessary to invoke the use of this switch when using the 'Multiple
Isometrics In Each Plotfile' option (Option Switch 31=0) and the required
Plotfile Length is different to the built-in default value of 3275 mm.

Switch Settings

Default for Plotfile Length of 3275 mm.

Value

Where Value is set to the required Plotfile Length in whole mm's.


Note. The maximum length is limited to 3350 mm.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

1.0

APR 83

Details

OPT - 1
Switches
by number
Switches
by name

-1-

ALIAS

2.

Cut piece numbering/list type

Options

ISOGEN
Switch Title

Option Switch No.

CUT PIECE NUMBERING / LIST TYPE

Description

The primary purpose of this Option Switch is to control the generation of


the Cut Piece List and corresponding Cut Piece Identifiers (Numbers or
Letters) at appropriate positions along the Plotted Pipeline.
An option to have Cut Piece Identifiers (Numbers or Letters) starting a 1
or A on each isometric as opposed to each pipeline is also controlled here.
There are two types of Cut Piece List - Old style with limited information
and New style with full information.
Finally, for Imperial Units Users- there is an Option to have the Cut
Lengths listed on the New Style Cut piece List in Decimal Inches format.
This being in addition to the regular value in the LENGTH column.
Cut Piece Numbers can now be output on the isometric in a variety of
alternative enclosure types which are controlled by Switch position 7 and 8
Switch Settings

SWITCH POSITION 1 -Cut Piece Numbering and Cut Piece List on/off
control.
0

Default for No Cut Piece List or Cut Piece Identification


Numbers/Letters.
Cut Piece List and Cut Piece Identifiers generated.
Cut Piece Identifiers starting at 1 (one) or A on each isometric
drawing.

1
2

SWITCH POSITION 2 -Cut Piece List Style.


0
1

Default for old style Cut Piece List.


For new style Cut Piece List
8

Blank,
Blank or 1 0 to 8 1 or 2

Switch Layout
Switch
Position
0,1 or 2

Zero or
one

Related Program Development Specs.


DEV. NO. 48 - ISOMETRIC REPEATABILITY.
DEV. NO. 56 - USER DEFINED BOM.
Related Option Switches.

First
Introduced
Extended
Use

Version

Date

1.0

APR 83

5.9.3

JUN 90

7.0

OCT 93

OPT - 2

ISSUE 3

Details
Switches
by number
Switches
by name

-2-

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

CUT PIECE NUMBERING / LIST TYPE

2 Cont.

SWITCH POSITION 3 - Alphabetic Cut Piece Identifiers.


0
1

Default for Numeric Cut Piece Identifiers.


For Alphabetic Cut Piece Identifiers.

SWITCH POSITION 4 - Supplementary output of Cut Length in Decimal


Inches.
0
1

Default for standard Cut Lengths only.


For supplementary output of Cut Lengths in Decimal Inches
format in the REMARKS column of the New Style Cut Piece
List. (This option only applies to users who use Imperial
Units).

SWITCH POSITION 5 - Calculation of Branch Cut Length to centre of


main pipeline.
0
1
2

Default for calculation to actual Branch connection point.


E.g. normal set-on tee.
Calculation to the centre line of the main pipeline in ALL
situations.
Use co-ordinate position.

SWITCH POSITION 6 -

Pipe Bending File

Pipe fabrication information including details of each cut


piece, listing the length, diameter, end preparation, material
part number, and other related details to assist
manufacturing. In addition bending information giving
distances to/between bends, angle and radius details are also
output.

Pipe fabrication information as described above but also


including details to enable profiling the shaped ends of pipe
and the cutting of holes (for tees, olets, crosses, etc).

OPT - 2

ISSUE 3

-3-

Details
Switches
by number
Switches
by name

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

CUT PIECE NUMBERING / LIST TYPE

2 Cont.

Switch Settings

SWITCH POSITION 6 -

Pipe Bending File

Pipe fabrication information including details of each cut


piece, listing the length, diameter, end preparation, material
part number, and other related details to assist
manufacturing. In addition bending information giving
distances to/between bends, angle and radius details are also
output.

Pipe fabrication information as described above but also


including details to enable profiling the shaped ends of pipe
and the cutting of holes (for tees, olets, crosses, etc).

SWITCH POSITION 7 0
1
2
3
4
5
6
7
8

Pointed brackets .
Diamond ended box.
Round ended box.
Triangular enclosure.
Diamond enclosure.
Square ended box.
Circular enclosure.
Elliptical enclosure.
Hexagonal ended box.

SWITCH POSITION 8 0
1

Cut Piece Enclosure Types

Single / Double line enclosure

Standard single line enclosure.


Double line enclosure (Circular/Elliptical enclosures only).

SWITCH POSITION 9 - Additional Material to be included on the Cut


Pipe List / Report
0
1
2
3

No entry to Cut List for Additional Material.


Add entry to Cut List for Additional Material (PIPE).
Add entry to Cut List for Additional Material (MISC).
Add entry to Cut List for Additional Material (PIPE and
MISC).

OPT - 2

ISSUE 3

-4-

Switches
by number
Switches
by name

ALIAS

3.

Drawing trim marks

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING TRIM MARKS

Description

This Option Switch controls the generation of Trim Marks for the plotted
isometric drawing.
These Trim Marks indicate the extremities of the nominated drawing size
(as set by either Option Switch 14 or Option Switches 15 and 16) and are
used as guides when trimming the plots produced on a continuous paper
type plotter.
Switch Settings

Default for No Trim Marks to be generated.

Plotted Trim Marks to be generated to indicate the extremities of


each plotted isometric.

Switch Layout

Switch
Position

Either
Setting
Related Program Development Specs.
First
Introduced

NONE
Related Option Switches.

Version

Date

1.0

APR 83

Extended
Use

Details

OPT - 3
Switches
by number
Switches
by name

-5-

ALIAS

4.

Drawing text size

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING TEXT SIZE

Description

This Option Switch is used to control the physical size of the Characters that
are used for Dimensions, Co-ordinates and Message Text, etc. on the 'picture
section' of the isometric drawing.
Note. Title Block Text which is always output using Large Characters
(2.8mm) and Material List Text which is controlled either by Option Switch
No. 27 or the Material List Definition File will not be affected by the setting
of this Switch.
Switch Settings

SWITCH POSITION 1 & 2


0
1
2
3
4
5
10 to 99

Character Height

Default for Medium size characters - 2.4mm high.


For Small size characters - 2.1mm high.
For Large size characters - 2.8mm high.
For Extra Large size characters - 3.5mm high.
For Extra Large size characters - 4.2mm high.
For Extra Large size characters - 4.9mm high.
Character Height in 1/10mms

Switch Layout

Blank or Value Spare

Future

0 or Value

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.

Switch
Position

Extended
Use

Version

Date

1.0

APR 83

7.4

DEC 95

8.6.0 APR 01

OPT - 4

ISSUE 2

Details
Switches
by number
Switches
by name

-6-

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING TEXT SIZE

4 cont.

Description

Controls text attributes allowing height, width, thickness and font to be


user controlled.
Text height can be set in 10th mm increments in a range between
1.0mm and 9.9mm.
Text width can be set on 10th mm to allow the height/width ratio to be
varied.
Text thickness can be set.
Text font can be varied, this is achieved by selecting a font from the Font
Information File (Fontstd.fif).

Switch Settings

OPTION SWITCH 3 & 4 Character Width


10 to 99

Character width in mms

OPTION SWITCH 5
1 to 9

(To be included in the future)

Character Thickness (Weight)

Character thickness in mms

OPTION SWITCH 6

(To be included in the future)

(SPARE)

OPTION SWITCH 7, 8 and 9


Number corresponding to entry in appropriate Font
Information File. Set to Zero or Blank will use default font.

Version

Related Program Development Specs.

Date

Extended
Use

NONE
Related Option Switches.

OPT - 4

ISSUE 2

Switches
by number
Switches
by name

-7-

ALIAS

5.

Co-ordinates - Connection/connectivity

Options

ISOGEN
Switch Title

Option Switch No.

CO-ORDINATES - CONNECTION/
CONNECTIVITY

Description

This facility is for the selective suppression from the Isometric of the
Co-ordinate information that is associated with each of the seven Pipeline
End Connection / Termination Identifiers in -30 to -36 type records, and at
any Break In Point (B.I.P.) identifier position in -47 type records.
Each type is controlled by a separate position in the Option Switch as
indicated in the layout below.
Switch Settings

The Co-ordinate type identifiers are :IDF


PURPOSE
ISO TEXT
RECORD NO.
Continuation on another pipeline
CONT. ON
-30
Connected to Equipment Nozzle Etc.
CONN. TO
-31
Identify any Open End of pipework
User Defined Text
-32
Identify any Closed End of pipework
User Defined Text
-33
Identify a Vent position
VENT
-34
Identify a Drain position
DRAIN
-35
Identify any miscellaneous position
User Defined Text
-36
Identify a Break-In Point
-47
Each Option Switch position should be set to :0
For ISO TEXT (See above) and associated Co-ordinates to be
shown on the isometric.
1
For ISO TEXT (See above) with No Co-ordinates to be shown
on the isometric.
Where appropriate, leading zeros may be omitted to give blank positions.

Switch Layout

-47
Rec

-36
Rec

-35
Rec

-34
Rec

-33
Rec

-32
Rec

-31
Rec

-30
Rec

Related Program Development Specs.


DEV. NO. 29 - END CO-ORDS. SUPPRESSION.
DEV. NO. 47 - GHOST GAP FACILITY.
Related Option Switches.

First
Introduced
Extended
Use

Switch
Position

Version

Date

5.4

APR 87

5.9

MAR 90

Details

OPT - 5
Switches
by number
Switches
by name

-8-

ALIAS

6.

Date output

Options

ISOGEN
Switch Title

Option Switch No.

DATE OUTPUT

Description

This Option Switch is used to select the Date format that is to be output on the
isometric drawing and printed listings in 2/4 digit year format.
The actual Date that is output is taken automatically from either the Pipeline
Data File that has been created by the host 3D Design System, or the
Computer System Date at run time.
As shown below, there are three format options plus an Option Switch setting
to suppress any Date Output, even though a Date may exist in the IDF.
Switch Settings

SWITCH POSITIONS 1 & 2 - Date Output/Format.


0
Default British format - e.g. 14 APR 92
1
For European format - e.g. 14/04/92
2
For American format - e.g. 04/14/92
3
For no plotted Date to be output.
10
System Date in British format.
11
System Date in European format.
12
System Date in American format.
SWITCH POSITION 3 - 2/4 Digit Year Output.
0 or Blank
1

Output 2 digit year format.


Output 4 digit year format (e.g. 14/04/1992).

Switch Layout

1
0

0, blank
or 1

Switch
Position

All
Settings

Related Program Development Specs.


VERSION 7.0 - RELEASE NOTES
DEV. NO. 74B - FOUR DIGIT YEAR
Related Option Switches.

Version

Date

First
Introduced

1.0

APR 83

Extended
Use

7.1

JUN 94

7.16.0

MAY 99

Details

OPT - 6
Switches
by number
Switches
by name

-9-

ALIAS

7.

Pipeline splitting - User control

Options

ISOGEN
Switch Title

Option Switch No.

PIPELINE SPLITTING - USER CONTROL

Description

Identifies the method to be used when Splitting Pipelines into multiple


isometric drawings. Two methods are available :i) Automatic Splitting. The automatic Split routine calculates the volume of
Pipeline graphics that can be satisfactorily displayed on the selected
DRAWING SIZE, and generates the required number of isometrics to
contain the complete Pipeline.
ii) A fixed number of drawings. With this method the User directly dictates
how many isometric drawings are to be produced for a Pipeline.
Notes.
a) The setting in Position 1 of this Switch will be ignored if Manual
Pipeline Split Points are present in the Pipeline Data file.
b) Method ii) should only be used in special cases for single Pipeline runs,
since any Option Switch setting applies to all the Pipelines in a run.
An added Option permits any Drawing Split Points input in the 3D model
by the User and present in the Piping Data file to be ignored.

Switch Settings

This Option Switch is in two parts.

SWITCH POSITIONS 1 & 2 - Various controls.


0
Default for automatic Split Control.
Value
Where value is equal to the number of drawings required.
(Continued overpage)
Switch Layout

Blank
or one

Switch
Position

Zero or
Value

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.

Extended
Use

38

Version

Date

1.0

APR 83

7.7

AUG 96

OPT - 7

Details
Switches
by number
Switches
by name

- 10 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

PIPELINE SPLITTING - USER CONTROL

7 Cont.

Description

Switch Settings

(Continued from previous page)

SWITCH POSITION 3 - Ignore Drawing Split Points.


1

To have User Defined Drawing Split Points present in the


Piping Data file ignored.

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Details

Extended
Use

38

OPT - 7

Switches
by number
Switches
by name

- 11 -

ALIAS

8.

Dimension line standout

Options
Options

ISOGEN
ISOGEN
Switch Title
Switch Title

Option Switch No.


Option Switch No.

DIMENSION LINE STANDOUT


DIMENSION LINE STANDOUT

88

Description
Description

This is a basic Option Switch for controlling Dimension Line Standout


This is a basic
Distances
for :-Option Switch for controlling Dimension Line Standout
Distances
:a) String & for
Composite
dimensions that are normally plotted as the middle
a)layer
Stringof&multi-layer
Compositedimensions.
dimensions that are normally plotted as the middle
layer
of
multi-layer
dimensions.
b) Dimensioned Messages, Support Dimensions and Reference dimensions on
b)the
Dimensioned
Support
Dimensions
and Reference
inner layer,Messages,
but only when
a Standout
Distance
in Optiondimensions
Switch 40 ison
theset.
inner layer, but only when a Standout Distance in Option Switch 40 is
not
not set. dimensions on the outer layer, but only when a Standout Distance
c) Overall
c) inOverall
Optiondimensions
Switch 118on
is the
not outer
set. layer, but only when a Standout Distance
in Option
is not
Note.
ValuesSwitch
set to <118
= 11
mm.set.
will be ignored by the program and
Note. Values
< = 11 mm. Standard
will be ignored
by theLine
program
and
substituted
byset
thetoappropriate
Dimension
Standout
substituted by the appropriate Standard Dimension Line Standout
distance.
distance.
(Continued overpage)
(Continued overpage)

Switch Settings
Switch Settings

0
0
Value
Value

Default for standard Dimension Line Standouts (see below).


Default for standard Dimension Line Standouts (see below).
Where value equals the required Standout distance for String &
Where value
equals the
Standout
String
Composite
dimensions
onrequired
the middle
layer - distance
in wholefor
mm's
. &
Composite dimensions on the middle layer - in whole mm's .
Standard Dimension Line Standout distances are :Standard
Dimension
Line
Standout
For
Small size
Drawing
Text
(Optiondistances
Switch 4 are
= 1):Small
size Drawing
Text (Option
Switch
4=
1)
a)For
String
/ Composite
Dimension
Standout
= 12
mm
a)Messages
String / Composite
Dimension
Standout
= 12Standout
mm
b)
/ Support &
Reference
Dimension
= 6 mm
Messages
/ SupportStandout
& Reference
Dimension Standout = 6 mm
c)b)Overall
Dimension
= 18 mm
c) Overall Dimension Standout = 18 mm
(Continued over page)
(Continued over page)

Switch Layout
Switch Layout

4
4

3
3

2
2

1
1

0
0
0 or 1
0 or 1

0 or Value
0 or Value

Related Program Development Specs.


Related Program Development Specs.
DEV. NO. 53 - ISOPLOT PROGRAM UPDATE.
DEV.
53 - ISOPLOT
V8.8.0 -NO.
RELEASE
NOTESPROGRAM UPDATE.
V8.8.0 - RELEASE NOTES
Related Option Switches.
4
118
Related Option Switches.

ISSUE 2
ISSUE 2

Switch
Switch
Position
Position

First
First
Introduced
Introduced
Extended
Extended
Use
Use

Version
Version

Date
Date

1.0
1.0
6.0
6.0
7.4
7.4

APR 83
APR 83
MAR 91
MAR 91
DEC 95
DEC 95

Details

OPT - 8
OPT - 8

Switches
by number
Switches
by name

- 12 -

ALIAS

Options
Options
Option Switch No.

ISOGEN
ISOGEN
Switch Title
Switch Title
DIMENSION

LINE STANDOUT
DIMENSION LINE STANDOUT
Description

Option Switch No.

8 Cont.

This is a basic Option


Switch for
controlling
Dimension Line Standout
Description
(Continued
from
previous page)

Distances for :When the Option Switch value is set > 11 mm. - that value is used by the
a) String
Composite
dimensions
that are
normally
plotted&as the middle
program
to set&
the
Dimension
Line Standout
distance
for String
layer
of multi-layer
dimensions.
Composite
dimensions
on the
middle layer.
b) Dimensioned Messages, Support Dimensions and Reference dimensions on
The inner
layer
Dimensioned
Messages,
Support
Dimensions
thedimension
inner layer,
butfor
only
when a Standout
Distance
in Option
Switch 40 is
and Reference
not set.Dimensions will then be set to 0.5 X this distance, while the
outerc)layer
Overall
Dimensions
willouter
be setlayer,
to 1.5but
X .only when a Standout Distance
Overall
dimensions
on the
in Option Switch 118 is not set.
Note.
Values setLine
to < Standout
= 11 mm. distances
will be ignored
by thefrom
program
(Standard Dimension
- continued
the and
substituted
by the appropriate Standard Dimension Line Standout
previous
page)
distance.
For Medium
size Drawing Text (Option Switch 4 = 0)
a) String / Composite Dimension Standout
= 14overpage)
mm
(Continued
b) Messages / Support & Reference Dimension Standout = 7 mm
c) Overall
Dimension Standout = 21 mm
Switch Settings
Default Text
for standard
Line Standouts (see below).
For 0Large size Drawing
(Option Dimension
Switch 4 = 2)
a) String / Composite Dimension Standout = 16 mm
Value / Support
Where&value
equals Dimension
the required
Standout
b) Messages
Reference
Standout
= 8distance
mm for String &
Composite
dimensions
on
the
middle
layer
in
whole mm's .
c) Overall Dimension Standout = 24 mm
Dimension
Line Standout
distances
are
For Standard
Extra Large
size Drawing
Text (Option
Switch
4 =:- 3)
For Small
size Drawing
Text Standout
(Option Switch
4 = 1)
a) String
/ Composite
Dimension
= 18 mm
a) String/ /Support
Composite
DimensionDimension
Standout =Standout
12 mm = 9 mm
b) Messages
& Reference
b) Messages
/ Support
& Reference
c) Overall
Dimension
Standout
= 27 mmDimension Standout = 6 mm
c) Overall Dimension Standout = 18 mm
For Extra Large size Drawing Text (Option Switch 4 = 4)
a) String / Composite Dimension Standout = 20 mm
(Continued over page)
b) Messages / Support & Reference Dimension Standout = 10 mm
c) Overall
Dimension Standout = 30 mm
Switch Layout
Switch
2
3
4
1
For Extra Large size Drawing Text (Option Switch 4 = 5) Position
a) String / Composite Dimension Standout = 22 mm 0
b) Messages / Support & Reference Dimension Standout = 11 mm
c) Overall Dimension Standout = 33 mm
0 or 1
0 or Value
Related Program Development Specs.
DEV. NO. 53 - ISOPLOT PROGRAM UPDATE.
V8.8.0 - RELEASE NOTES
Related Option Switches.

118

ISSUE 2
ISSUE 2

Version

Date

First Version
Date
APR 83
1.0
Introduced
Extended
8.6.0
APR 01
6.0
Use Extended
MAR 91
Use

01 95
8.8.0 7.4JUL DEC

OPT - 8
OPT - 8

Details
Switches
by number
Switches
by name

- 13 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

DIMENSION LINE STANDOUT


Description

8 Cont.

(Continued from previous page)

Dimension text and messages placed along a section of pipe in isometric projection
(oblique angle \ slanted text).
This feature is only available for DXF format output styles generated via the POD
interface.
Text oblique angle will be adjusted to be parallel to the dimension standout
direction.
ISOGEN will attempt to set a vertical dimension standout for horizontal sections of
pipeline wherever practical.
Switch Settings

SWITCH POSITION 3 - Isometric Text


0
1

Standard text
Isometric text

SWITCH POSITION 4
0
1

Vertical Dimension Standout

Normal selection criteria used to determine directional


standout.
Vertical dimension standout wherever possible.

Version

Date

Extended
Use

ISSUE 2

OPT - 8

Switches
by number
Switches
by name

- 14 -

ALIAS

9.

Dimension form

Options

ISOGEN
Switch Title

Option Switch No.

DIMENSION FORM

Description

Controls basic Dimensioning requirements on the isometric :i) Dimension Type - String/Composite, Support/Comment, Reference
Location and Full String.
ii) Component Dimensions to include or exclude Gaskets.
iii) USA style dimensions (positioned on top of the Dimension Line).
iv) Additional allowances for pipe dimensions.
v) Double dimensioning - imperial or metric
vi) Dimensioning Multi-way Valves and Instruments.
This Option Switch is in nine parts.

Switch Settings

SWITCH POSITION 1 - Various Controls


0

Default setting which provides basic String Dimensions,


Support / Message Dimensions, and Reference Dimensions.
For an isometric with String Dimensions and
Support/Message location Dimensions suppressed. That is,
only Reference Dimensions will be plotted.
For the output of Support/Message and Reference Location
Dimensions only.
Same as value 0 except Composite Dimensions are output
instead of String.
Same as value 0 except Full String Dimensions are output
instead of Ordinary String Dimensions. That is, all
components are individually dimensioned.

2
3
4

Switch
Position

Blank or
or one

Switch Layout

All
Settings

Version Date
Related Program Development Specs.
DEV. NO. 19 - IMPROVED DIMENSIONING.
First
APR 83
DEV. NO. 59 - DIMENSIONING UPGRADE.
Introduced 1.0
DEV.NO. 83F - DIMENSIONING ENHANCEMENTS
Related Option Switches.
OCT 86
Extended 5.0
Use

40

118

119

- 15 -

Details

7.0

OCT 93

8.5.4

DEC 00

Switches
by number

8.6.0 FEB 01
8.7.0 APR 01

Switches
by name

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

DIMENSION FORM
Switch Settings

9 Cont.

(Continued from previous page)

SWITCH POSITION 2 - Dimensioning of Gaskets.


0
1
2

For component dimensions not to include Gaskets.


For component dimensions to include Gaskets.
For separate dimensioning of Gaskets.

SWITCH POSITION 3 - USA Style Dimensions.


Blank
1

Default for regular Dimensioning style.


(i.e. Inserted into Dimension line).
For USA Dimensioning style.
(i.e. Positioned on top of Dimension line).

SWITCH POSITION 4 - Dimensions at 90 degrees


0
1

Dimensions turned 90 degrees rather than being arrowed


out.
(Note. 0 and 1 at Beta test stage Feb 2001.)

SWITCH POSITION 5 - Additional allowances shown with dimension


output
0
For normal component dimensions.
1
For dimensions to show additional allowances.
2
For dimensions to include additional allowances (Spool
isometrics only)

SWITCH POSITION 6 - Bend Dimensioning


0
1

Combined pipe and bend dimensions.


Separate pipe and bend dimensions.

Details
SWITCH POSITION 7 - Double dimensioning - Imperial and Metric.
0
1

Switches
by number

For single dimensioning.


For double dimensioning.

Switches
by name

- 16 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

DIMENSION FORM
Switch Settings

9 Cont.

(Continued from previous page)

SWITCH POSITION 8 - Dimensioning of Angle / 3 Way / 4 Way Valves


and Instruments
0
1

Angle / 3 Way / 4 Way Valve and Instruments dimensioned


using message.
Angle / 3 Way / 4 Way Valve and Instruments dimensioned
normally.

SWITCH POSITION 9 - Jacket Dimension Control


0
1

Full Jacket Dimensioning


Jacket Dimensioning suppressed.

Basic string dimensioning where dimensions combine


erection/offshore pipe fittings with adjacent pipe/pipe fitting.
Composite where dimensions combine erection/offshore pipe
fittings with adjacent pipe/pipe fitting.

Related Program Development Specs.


DEV. NO. 89D - JACKET PIPING SYSTEMS.
9.0.0 RELEASE NOTES

Extended
Use

9.0

MAY 08

Switches
by number
Switches
by name

- 17 -

ALIAS

10. Drawing margin - Left

Options

ISOGEN
Switch Title

Option Switch No.

10

DRAWING MARGIN -LEFT


Description

Controls the Left Hand side Drawing Margin.


The Drawing Margin is the distance between the outer edge of the Drawing
Sheet and the outer line of the Drawing Frame that is being used.

Switch Settings

SWITCH POSITIONS 1, 2 & 3 - Drawing Margin - Left.


0
Value

Default for 5mm, Left Hand Margin.


Where value is the Left Hand Margin setting in whole mms.

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


NONE

First
Introduced

Related Option Switches.

Extended
Use

11

12

13

1.0

Date

APR 83

Details

OPT - 10
Switches
by number
Switches
by name

- 18 -

ALIAS

11. Drawing margin - Right

Options

ISOGEN
Switch Title

Option Switch No.

11

DRAWING MARGIN - RIGHT


Description

Controls the Right Hand side Drawing Margin.


The Drawing Margin is the distance between the outer edge of the Drawing
Sheet and the outer line of the Drawing Frame that is being used.

Switch Settings

SWITCH POSITIONS 1, 2 & 3 - Drawing Margin - Right.


0
Value

Default for 5mm, Right Hand Margin.


Where value is the Right Hand Margin setting in whole mms.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

1.0

APR 83

Details

10

12

Switches
by number

13
OPT - 11

- 19 -

Switches
by name

ALIAS

12. Drawing margin - Top

Options

ISOGEN
Switch Title

Option Switch No.

12

DRAWING MARGIN -TOP


Description

Controls the Drawing Margin at the Top of the drawing.


The Drawing Margin is the distance between the outer edge of the Drawing
Sheet and the outer line of the Drawing Frame that is being used.

Switch Settings

SWITCH POSITIONS 1, 2 & 3 - Drawing Margin - Top.


0
Value

Default for 5mm, Top Margin.


Where value is the Top Margin setting in whole mms.

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


NONE

First
Introduced

Related Option Switches.

Extended
Use

10

11

13

1.0

Date

APR 83

Details

OPT - 12
Switches
by number
Switches
by name

- 20 -

ALIAS

13. Drawing margin - Bottom

Options

ISOGEN
Switch Title

Option Switch No.

13

DRAWING MARGIN - BOTTOM


Description

Controls the Drawing Margin at the Bottom of the drawing.


The Drawing Margin is the distance between the outer edge of the Drawing
Sheet and the outer line of the Drawing Frame that is being used.

Switch Settings

SWITCH POSITIONS 1, 2 & 3 - Drawing Margin - Bottom.


0
Value

Default for 5mm, Bottom Margin.


Where value is the Bottom Margin setting in whole mms.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

10

11

12

Version

Date

1.0

APR 83

Details

OPT - 13
Switches
by number
Switches
by name

- 21 -

ALIAS

14. Drawing size - Standard postscript plotter size

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING SIZE - STANDARD


POSTSCRIPT PLOTTER SIZE

14

Description

Controls Drawing Size when a standard one conforming to the European


Metric 'A' series or an Inch based American ANSI paper sizes 'A' to 'E' is
required.
A secondary function controlled by this Option Switch is the setting of the
Postscript output device size for both standard and non-standard Drawing
Sizes.
Note. Non-standard Drawing Sizes are controlled by Option Switches 15 &
16 which if set overrides any setting in Option Switch 14.
Switch Settings

This Option Switch is in two parts.

SWITCH POSITIONS 1 & 2 - Drawing Sheet Size.


0
1
2
3
4
10

Default for European A2 paper size (420 x 594 mm).


For European A1 paper size (594 x 841 mm).
For European A2 paper size (420 x 594 mm).
For European A3 paper size (297 x 420 mm).
For European A4 paper size (210 x 297 mm).
For European A0 paper size (841 x 1189 mm).

5
6
7
8
9

For ANSI 'D' paper size (22" x 34").


For ANSI 'C' paper size (17" x 22").
For ANSI 'B' paper size (11" x 17").
For ANSI 'A' paper size (8.1/2" x 11").
For ANSI 'E' paper size (34" x 44").
(Continued over page)

Switch Layout

Blank or
Value

Switch
Position

Zero or
Value

Related Program Development Specs.


VERSION 6.0 - RELEASE NOTES.

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

1.0

APR 83

6.0

MAR 91

Details

OPT - 14
Switches
by number
Switches
by name

- 22 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING SIZE -STANDARD


POSTSCRIPT PLOTTER SIZE

14 Cont.

Description

Switch Settings

(Continued from previous page)

SWITCH POSITIONS 3 & 4 - PostScript Plotter size.


0 or blank For Default European A3 paper size (297 x 420 mm).
1
2
3
4
10

For European A1 paper size (594 x 841 mm).


For European A2 paper size (420 x 594 mm).
For European A3 paper size (297 x 420 mm).
For European A4 paper size (210 x 297 mm).
For European A0 paper size (841 x 1189 mm).

5
6
7
8
9

For ANSI 'D' paper size (22" x 34").


For ANSI 'C' paper size (17" x 22").
For ANSI 'B' paper size (11" x 17").
For ANSI 'A' paper size (8.1/2" x 11").
For ANSI 'E' paper size (34" x 44").

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

Details

OPT - 14
Switches
by number
Switches
by name

- 23 -

ALIAS

15. Drawing size - Height

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING SIZE -HEIGHT

15

Description

Defines isometric Drawing Height for non-standard paper sizes. That is,
sizes that do Not conform to either the European 'A' series, or the Inch
based American ANSI sizes.
Notes.
1) Where the plotted output is to a PostScript output device, the device size
must be set in Option Switch 14 (unless European A3 size is being used).
2) Standard drawing sizes are controlled by Option Switch 14.

Switch Settings

SWITCH POSITIONS 1, 2, 3 & 4 - Drawing Size - Height.


0
Value

Default for No non-standard Drawing Height.


Where value is the overall Drawing Height in whole mms.

(This Option Switch MUST be used in conjunction with Option Switch 16


- DRAWING SIZE - WIDTH).

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

14

16

Version

Date

1.0

APR 83

Details

OPT - 15
Switches
by number
Switches
by name

- 24 -

ALIAS

16. Drawing size - Width

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING SIZE -WIDTH

16

Description

Defines isometric Drawing Width for non-standard paper sizes. That is,
sizes that do Not conform to either the European 'A' series, or the Inch
based American ANSI sizes.
Notes.
1) Where the plotted output is to a PostScript output device, the device size
must be set in Option Switch 14 (unless European A3 size is being used).
2) Standard drawing sizes are controlled by Option Switch 14.

Switch Settings

SWITCH POSITIONS 1, 2, 3 & 4 - Drawing Size - Width.


0
Value

Default for No non-standard Drawing Width.


Where value is the overall Drawing Width in whole mms.

(This Option Switch MUST be used in conjunction with Option Switch 15


- DRAWING SIZE - HEIGHT).

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

14

15

Version

Date

1.0

APR 83

Details

OPT - 16
Switches
by number
Switches
by name

- 25 -

ALIAS

17. Flow arrows - Components

Options

ISOGEN
Switch Title

Option Switch No.

FLOW ARROWS -COMPONENTS

17

Description

This Option Switch controls the use of Flow Arrows that are plotted
alongside certain types of in-line components. Their purpose is to show the
Pipeline's Fluid or Gas Flow direction.
Note. A different type of User positioned Flow Arrow which is plotted
directly on the pipe may also be used, either as well as, or instead of the
component Flow Arrow. For details of this alternative type, see Option
Switch 112.
Switch Settings

Default to obtain Flow Arrows plotted alongside certain types of


in-line components.

To suppress the plotting of component Flow Arrows.

Switch Layout

Switch
Position

Either
Setting
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

1.0

APR 83

Details

OPT - 17
Switches
by number
Switches
by name

- 26 -

ALIAS

18. Drawing frame - Program standard

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING FRAME PROGRAM STANDARD

18

Description

Controls whether or not the standard ISOGEN Drawing Frame is plotted.


It is likely that Users who either plot their own design of Backing Frame or
plot to Frames on pre-printed forms, will wish to suppress the plotting of
the standard ISOGEN Drawing Frame.

Switch Settings

Default to obtain the standard ISOGEN Drawing Frame.

To suppress the plotting of the ISOGEN Drawing Frame.

Switch Layout

Switch
Position

Either
Setting
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

1.0

APR 83

Details

OPT - 18
Switches
by number
Switches
by name

- 27 -

ALIAS

19. Sloping pipeline indication method

Options

ISOGEN
Switch Title

Option Switch No.

SLOPING PIPELINE INDICATION


METHOD

19

Description

This Option Switch controls how sections of Falling Pipelines (that is


downward slopes) are to be indicated on the isometric.
The switch determines the method of how the Fall value is to be indicated
numerically on the isometric from one of the options shown below.
A further option is to suppress Fall type slope indication.
Switch Settings

Switch Position 1 - Fall depiction


0

Default for Falls shown as an Angle. e.g. FALL 1.5.

For Falls shown as a Ratio. e.g. FALL 1:38.

For Falls shown as a Percentage. e.g. FALL 2.6%.

For Falls shown as a Gradient. e.g. FALL 1.6 GRAD.

For Falls shown as an Imperial Incline. e.g. 5/16" PER FOOT.

For Falls shown as a Metric Incline. e.g. FALL 26 MM PER M.

To suppress Falling Line indication.

Switch Layout

Switch
Position

Blank, 1,
2 or 3

All
Settings

(Continued over page)

Related Program Development Specs.


NONE

First
Introduced

Related Option Switches.

Extended
Use

20

Version

Date

1.0

APR 83

8.11.0

APR 03

OPT - 19

Details
Switches
by number
Switches
by name

- 28 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

SLOPING PIPELINE INDICATION


METHOD

19 Cont.

Description

Switch 19 Position 2, now gives the user greater control over the accuracy
of sloping pipeline indication.
(The settings in Position 2 are governed by how the fall is to be indicated
once the data has been entered in Position 1. )
(Continued from previous page)

Switch Settings

Switch Position 2 - Accuracy of sloping pipeline indication.


Fall shown as an Angle
0
1
2
3

Angle output to nearest 10th degree


Angle output to nearest degree
Angle output to nearest 100th degree
Angle output to nearest degree and minutes

Fall shown as an Ratio


0
1
2

Ratio output to nearest 5 when greater than 1:30


Ratio output to nearest 5 when greater than 1:100
Ratio output to nearest 1

Fall shown as an Percentage


0
1
2

Percentage output to nearest whole value


Percentage output to nearest 1 decimal place
Percentage output to nearest 2 decimal places

(Continued over page)


Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

1.0

APR 83

8.11.0

APR 03

OPT - 19

Switches
by number
Switches
by name

- 29 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

SLOPING PIPELINE INDICATION


METHOD
Switch Settings

19 Cont.

(Continued from previous page)

Switch Position 2 - Accuracy of sloping pipeline indication contd.


Fall shown as an Gradient
0
1
2

Gradient output to nearest 10th grad


Gradient output to nearest grad
Gradient output to nearest 100th grad

Fall shown as an Imperial Incline (only when dimensions in decimal inches)


0
1

Incline output to nearest 16th of an inch per foot


Incline output to nearest 100th of an inch per foot

Fall shown as an Metric Incline


0
1
2

Incline output to nearest 5mms per metre


Incline output to nearest mm per metre
Incline to nearest 10mms per metre

Related Program Development Specs.


NONE

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

1.0

APR 83

8.11.0

APR 03

OPT - 19

Switches
by number
Switches
by name

- 30 -

ALIAS

20. Sloping pipeline indication limit

Options

ISOGEN
Switch Title

Option Switch No.

SLOPING PIPELINE INDICATION LIMIT

20

Description

This switch controls the cut-off value to be used when determining what
steepness of Slope should be treated as a Fall, and what should not.
Note. Slopes steeper than the cut-off value will be shown with a 2D or 3D
Box or Triangle skew indication as appropriate.

Switch Settings

Default for 5 angle cut-off or it's equivalent depending upon


the type of indication selected in Option Switch 19.

Value

Where Value is set to a cut-off number to suit the type of


indication selected in Option Switch 19.

e.g.

For 5 Degrees cut off enter 5 or 0


For 1:11 Ratio cut-off enter 11
For 9 Percent cut-off enter 9
For 5 Grads. cut-off enter 5
For 1" Per Foot cut-off enter 1
For 88 mm. per Metre cut-off enter 88

Note. This Option Switch should always be set to 0 when Sloping Pipeline
Indication has been suppressed by setting Option Switch 19 to 6.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
First
Introduced

NONE
Related Option Switches.

Version

Date

1.0

APR 83

Extended
Use

19

Details

OPT - 20
Switches
by number
Switches
by name

- 31 -

ALIAS

21. Isometric type

Options

ISOGEN
Switch Title

Option Switch No.

ISOMETRIC TYPE

21

Description

Controls the required Isometric Type. There are many variations, as defined
below.
The default option provides a Combined isometric containing a combination
of Fabrication, Erection and Offshore information as appropriate.
Switch Settings

This Option Switch is in two parts.

SWITCH POSITIONS 1 & 2 - Isometric Type.


0
1
2
4
5
6
7
10
11
12
16

Default for a Combined isometric (see above).


For an Erection / Offshore type isometric.
For a Fabrication only isometric.
For individual Flat Spool isometrics. (Maximum legs Flat).
For individual Flat Spool isometrics. (Maximum legs Parallel).
For individual Spool isometrics - 'As Built' orientation.
For isometric Suppression - No isometric drawings generated.
For a Combined Material List only, without Pipeline graphics.
For an Erection Material List only, without Pipeline graphics.
For a Fabrication Material List only, without Pipeline graphics.
For Spool Material List only, without Spool graphics.
(Continued over page)

Switch Layout

Switch
Position

All
All
Settings Settings
Related Program Development Specs.
DEV. NO. 63A - FLAT SPOOLS FACILITY.
DEV. NO. 74A - DISCONNECTED PIPELINES
Related Option Switches.

55

Version

Date

First
Introduced

1.0

APR 83

Extended
Use

7.1

JUN 94

7.4.2

JAN 96

7.16.0 MAY 99

Details

ISSUE 2

OPT - 21
Switches
by number
Switches
by name

- 32 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

ISOMETRIC TYPE

21 Cont.

Description

Switch Settings

(Continued from previous page)

SWITCH POSITION 3 - Test Isometric.


Blank
Generate normal isometric.
1
Generate a Test Isometric with all dimensions and Material
List quantities output as Xs. Does not decrement the
Hardware Lock count.
8
Increase tolerance to join disconnected components - set
to 8mm. See note below.
9
Produce separate drawings for disconnected pipeline when
increased tolerance used and switch 55, digit 3 set to 0.
See note below.
Notes

Value 8 and 9 are set internally and will not require the user
to take any action.

Switch Position 3 = 8

Switch Position 3 = 9

When a Minor break occurs at the By-pass


closure point then IDFGEN will set position 3 to
a value of 8 so that ISOGEN will still recognise
the By-pass situation that has been created.
A value of 9 will be set by IDFGEN in position
3 when certain conditions of Switch 55 are met.
ISOGEN will act upon this information to
output the Disconnected Pipeline message as
and when required.

Switch Layout
Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

Details

OPT - 21

ISSUE 2

Switches
by number
Switches
by name

- 33 -

ALIAS

22. Cut piece add-on allowance

Options

ISOGEN
Switch Title

Option Switch No.

22

CUT PIECE ADD-ON ALLOWANCES


Description

This switch controls the amount of extra Pipe that is added for the following
circumstances :1) At Loose Flange and Field Fit Weld (FFW) positions. Extra Pipe is added
both to Cut Pipe Length dimensions and to Pipe quantities on the Material
List. There are separate controls for On-shore and Off-shore values.
2) For Shop Test purposes where certain Welds are cut-off together with a
short length of pipe after testing.
Switch Settings

This Option Switch is in three parts.

SWITCH POSITIONS 1, 2 & 3 - FFW/Loose Flange Allowance, On-shore.


0
Default to obtain 0 mm. allowance.
Value
Where Value is an alternative allowance in whole mm's. e.g. 175.
SWITCH POSITIONS 4, 5 & 6 - FFW/Loose Flange Allowance, Off-shore.
0 or blank Default to obtain 0 mm. allowance.
Value
Where Value is an alternative allowance in whole mm's. e.g. 175.
SWITCH POSITIONS 7, 8 & 9 - Shop Test Weld Allowance.
Blank
Default to obtain 0 mm. allowance.
Value
Where Value is an alternative allowance in whole mm's. e.g. 175.
This is applied only to 'SHOP TEST' Welds.

Switch Layout

Blank or
Value

Zero, blank or
Value

Switch
Position

Zero or
Value

Related Program Development Specs.


DEV. NO. 57 - WELDING FACILITIES UPGRADE. First
DEV. NO. 63 - FLAT SPOOL FACILITY.
Introduced
Extended
Use

Version

Date

1.0

APR 83

7.0

OCT 93

7.1

FEB 94

Details

OPT - 22
Switches
by number
Switches
by name

- 34 -

ALIAS

23. Material list - Controls and File type

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL LIST - CONTROLS


MATERIAL LIST - FILE TYPE

23

Description

Controls the following integral Material List functions on the isometric.


i)
Material List On/Off
ii)
Special Type of List.
iii) Material List Style.
iv) Material Control File Type.
v)
Continuous or Sectionalised type of Material List.
Users who obtain the Material List by other means, for example by
printing it, or who do not require a Material List at all, may suppress it.
Switch Settings

This Option Switch is in five parts.


SWITCH POSITION 1 - Material List On/Off.
0
Default to have the Material List plotted integrally with the
isometric drawing.
1
To suppress the Plotted Material List.
SWITCH POSITION 2 - Special Type Material Lists.
0
Default for no Special Type Material List.
1
Special Type Material List - every item is given a separate
entry except Gaskets & Bolts which are accumulated, Pulled
Bends get 'U' pre-fixes, Welds have W or B pre-fixes.
2
No Special Type Material List, but use an alpha system of
Material List pointers, A, B, C etc. instead of the default
numeric system.
(Continued overpage)

Switch Layout

Switch
Position

All Settings
Version

Date

DEV. NO. 56 - USER DEFINED MATERIAL LIST. First


Introduced

1.0

APR 83

Related Option Switches.

7.0

OCT 93

7.4

DEC 95

Related Program Development Specs.

24 25 26 27 28 29 30 65 74
ISSUE 2

Extended
Use

Details

OPT - 23
Switches
by number
Switches
by name

- 35 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL LIST - CONTROLS


MATERIAL LIST - FILE TYPE

23 Cont.

Description

Switch Settings

(Continued from previous page)

SWITCH POSITION 3 - Material List Style.


0 or 1
Default for Style 1 Material List.
2
For Style 2 Material List.
3
For Style 3 Material List.
4
For Style 4 Material List.
SWITCH POSITION 4 - Type of Material Control File.
0
Default for Standard Material Control File.
1
For User Defined Material Control File.
SWITCH POSITION 5 - Style 2 Material List Layout pattern.
(Also works with Special Type Material List options
- OS23 Pos 2 = 1).
Blank
Default for the standard Sectionalised type with Group
Headings & Component sub-Group Headings.
1
For Continuous style listing without headings & Sub-headings.
This type of list is partitioned with horizontal dividing lines
between the logical Groups, e.g. PIPE, FLANGES, FITTINGS,
etc.
2
Same as value 1 except there are no dividing lines.

Switch Layout

Related Program Development Specs.

Version

Date

7.6

MAY 96

First
Introduced
Related Option Switches.

24 25 26 27 28 29 30 65 74

Extended
Use

Details

OPT - 23

ISSUE 2

Switches
by number
Switches
by name

- 36 -

ALIAS

24. Material list - Pipeline/drawing and Pipeline length units

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL LIST - PIPELINE / DRAWING


MATERIAL LIST - PIPE LENGTH UNITS

24

Description

This Option Switch controls two aspects of the Material List.


i) Whether it is produced on a per Drawing or per Pipeline basis. (This
difference only comes into effect when a Pipeline is split onto two or more
drawings).
ii) Linear Quantity output style.
Switch Settings

This Option Switch is in two parts.

SWITCH POSITION 1 - Material List per Drawing or per Pipeline.


0
1
2

Default for Material List per isometric drawing.


For Material List per Pipeline.
Spool isometric Material Part Numbers to match Full
isometric Part Numbers when using Material List per
Drawing facility.
Spool isometric Material Part Numbers to match Full
isometric Part Numbers when using Material List per
Pipeline facility.

Switch Layout

Switch
Position

Blank or Zero or
Value
Value
Version

Related Program Development Specs.


DEV. NO. 56 - USER DEFINED MATERIAL LIST.
9.0.0 RELEASE NOTES

Related Option Switches.

1.0

APR 83

Extended

7.0

OCT 93

7.6.2

MAY 96

O.S. 23 O.S. 24 0.S. 25 0.S. 26 0.S. 27 O.S. 28 O.S. 29 O.S. 30 Use

ISSUE 2

Date

First
Introduced

OPT - 24

Details
Switches
by number
Switches
by name

- 37 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL LIST - PIPELINE / DRAWING


MATERIAL LIST - PIPE LENGTH UNITS

24 cont

Switch Settings

SWITCH POSITION 2 - Linear Quantity Output Style.


Blank
1
2
3

Default for pipe length to be output in the form n.n M or n.n Feet. E.g. 10.4 M or 10.4.
For pipe length to be output in the form n MM or n Feet n Inches. E.g. 1040 MM or 10 5 .
For pipe length to be output in the form n.nnn M or n.nnn Feet. E.g. 1.045 M or 10.375.
For pipe length output to match form specified in O.S. 41.
The selected length style is applied on the Material List for
Pipe material entries and miscellaneous components, and on
the CL length summary. (Metric or Imperial units output is
governed by O.S. 41).

SWITCH POSITION 3 Materials by spool.


0
1

Spool materials incorporated within Fabrication category


Spool materials grouped separately, part numbering per
spool

Related Option Switches.

Extended
Use

8.10.5 NOV 02
9.0

MAY 08

OPT - 24

ISSUE 2

Switches
by number
Switches
by name

- 38 -

ALIAS

25. Material list and Title block- position

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL LIST - POSITION


TITLE BLOCK - POSITION

25

Description

This Option Switch controls two aspects of the Material List.


i) Whether the Material List is printed on the Left Hand or Right Hand
side of the isometric.
ii) The position of the Title Block.

This Option Switch is in two parts.

Switch Settings

SWITCH POSITION 1 - Material List position.


0
Default for Material List printed on the Left Hand side.
1

For Material List printed on the Right Hand side.

SWITCH POSITION 2 - Title Block position.


Blank
For Title Block in default position. (Bottom Right Hand
corner of pipeline drawing area).
1
For Title Block at bottom of Material List.
2
For Title Block to be suppressed.

Switch Layout

Switch
Position

Blank or Zero or
Value
Value
Version

Date

DEV. NO. 56 - USER DEFINED MATERIAL LIST. First


Introduced

1.0

APR 83

Related Option Switches.

7.0

OCT 93

Related Program Development Specs.

23

24

26

27

28

29

30

Extended
Use

Details

OPT - 25
Switches
by number
Switches
by name

- 39 -

ALIAS

26. Material list - Descriptions

Options

ISOGEN
Switch Title

Option Switch No.

26

MATERIAL LIST - DESCRIPTIONS


Description

This Option Switch controls whether or not Item Descriptions are printed
on the Material List and in the Bulk Materials file.
Note. When Item Descriptions are suppressed, the Material List becomes
correspondingly narrower.
Also controlled is the option of whether or not to have a Blank Line printed
after single line Material List entries.
Switch Settings

This Option Switch is in three parts.


SWITCH POSITION 1 - Item Descriptions On / Off control.
0
Default to have Item Descriptions printed.
1
To suppress Item Descriptions.
SWITCH POSITION 2 - Control of the insertion of Blank Lines following
single line Material List entries.
0 or blank Default to have Blank Lines inserted.
1
Not have Blank Lines inserted following single line entries. This
provides the possibility of the Material List being shorter.

SWITCH POSITION 3 - Output of Descriptions in Bulk Material file.


Blank
1
2

Default for no Descriptions.


No repeat Descriptions to be output.
All Descriptions to be output.

Switch Layout

Switch
Position

Either
Setting
Related Program Development Specs.
VERSION 7.0 - RELEASE NOTES.

First
Introduced

Related Option Switches.

Extended
Use

23

24

25

27

28

29

30

Version

Date

1.0

APR 83

7.1

JUN 94

7.14.4

JUL 98

Details

OPT - 26

ISSUE 3

Switches
by number
Switches
by name

- 40 -

ALIAS

27. Material list - Text size

Options

ISOGEN
Switch Title

Option Switch No.

27

MATERIAL LIST - TEXT SIZE


Description

This Option Switch controls the plotted Material List Text Size.
A range of sizes are available, as listed below.

Switch Settings

SWITCH POSITION 1 & 2


0
1
2
3
4
5
10 to 99

Character Height

Default for Medium size characters - 2.4mm high.


For Small size characters - 2.1mm high.
For Large size characters - 2.8mm high.
For Extra Large size characters - 3.5mm high.
For Extra Large size characters - 4.2mm high.
For Extra Large size characters - 4.9mm high.
Character Height in 1/10mms

Switch Layout

Switch
Position

All Settings
Related Program Development Specs.
First
Introduced

NONE
Related Option Switches.

23

24

25

26

28

29

30

ISSUE 2

Extended
Use

Version

Date

1.0

APR 83

7.4

DEC 95

Details

OPT - 27
Switches
by number
Switches
by name

- 41 -

ALIAS

28. Material list - Item code length

Options

ISOGEN
Switch Title

Option Switch No.

28

MATERIAL LIST - ITEM CODE LENGTH


Description

This Option Switch informs ISOGEN of how many characters should be


used for the Material List Item Code.

Switch Settings

Default for 8 characters in the Item Code.

Value

Where Value is an alternative number of characters. e.g. 12.

Notes.
a) The maximum number of permissible Item Code characters is 29.
b) A value of 0 gives 8 characters, it does Not cause the suppression of the
Item Code field on the Style 1 Material List.
c) Changes in this field causes the Material List to be correspondingly wider
or narrower.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

23

24

25

26

27

29

30

Version

Date

1.0

APR 83

Details

OPT - 28
Switches
by number
Switches
by name

- 42 -

ALIAS

29. Material list - Line spacing

Options

ISOGEN
Switch Title

Option Switch No.

29

MATERIAL LIST - LINE SPACING


Description

This Option Switch controls the Line Spacing distance on a plotted Material
List.

Switch Settings

0 or 100

Default corresponding to a Line Spacing value of 100.

Value

Where Value is an alternative number. Set to increase / decrease


the Line Spacing distance in the ratio Value / 100.
e.g. A Value of 90 will reduce the Line Spacing while a Value of
110 will increase it.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
First
Introduced

NONE
Related Option Switches.

23

24

25

26

27

28

30

Version

Date

1.0

APR 83

Extended
Use

Details

OPT - 29
Switches
by number
Switches
by name

- 43 -

ALIAS

30. Material list - Continuation method

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL LIST CONTINUATION METHOD

30

Description

Controls how a Material List Overflow situation is handled and how any
Overflow drawing is to be identified.
A secondary option offers control over the Drawing (Sheet) identification
method to be used for single isometric pipelines.

Switch Settings

Default to give automatic overflow onto a second Material List


plotted alongside the first. (This creates a wider non-standard
drawing size).
Gives a second 'Dummy' isometric containing the Overflow
Material List but no pipeline graphics.
This isometric will be allocated the next Drawing (Sheet) identifier
in the sequence.
Gives a second 'Dummy' isometric containing the Overflow
Material List but no pipeline graphics.
The isometric will be allocated the same Drawing (Sheet) identifier
as the previous (Master) isometric but supplemented with a 'A'
suffix letter.
Any further overflow drawings for the same Master isometric
will be suffixed 'B' 'C' etc.
(Continued overpage)

Switch Layout

Switch
Position

All
Settings

Zero or value

Version

Date

First
Introduced

1.0

APR 83

Extended
Use

5.9
9.0

MAR 90
MAY 08

Details

OPT - 30

Switches
by number

Related Program Development Specs.


DEV. NO. 48 - REPEATABILITY - PHASE 1.
9.0.0 RELEASE NOTES
Related Option Switches.

23

24

25

26

27

28

29

Switches
by name

- 44 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL LIST CONTINUATION METHOD


Switch Settings

30 Contd.

(Contd. from previous page)

10

Gives the same as value 0 except that DRG 1 OF 1 is added to


any single sheet isometrics for identification.

11

Gives the same as value 1 except that DRG 1 OF 1 is added to


any single sheet isometrics for identification.

12

Gives the same as value 2 except that DRG 1 OF 1 is added to


any single sheet isometrics for identification.

SWITCH POSITION 3 Sheet numbering leading zeros


0
x

No leading characters output before cut piece number.


Number of characters output in cut piece number.

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

23

24

25

26

27

28

29

Details

Extended
Use

OPT - 30

Switches
by number
Switches
by name

- 45 -

ALIAS

31. Drawing output - File/screen

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING OUTPUT - FILE / SCREEN

31

Description

Controls how and where any isometric drawing are to be output.


Controls whether or not plot files previously created can be overwritten if
their names match those currently being created.
Controls drawing sheet numbering.
Switch Settings

SWITCH POSITION 1 General plotfile control.


0
1
2
3

Default for isometric drawings generated during a run to be output


to either a single plot file or a series of plot files depending upon
the PLOTFILE LENGTH value set in O.S. 1.
For an individual plot file to be generated for each isometric
drawing.
For output of the generated isometric drawing(s) to the
workstation screen. The Terminal Type being used should be set in
O.S. 69.
For output of multiple isometric drawings on separate sheets. Valid
only for SmartSketch IGR & SmartPlant Shape2D formats.

SWITCH POSITION 2 Plotfile overwrite control.


0
1

Allocate next available plot file, generate name using selected


sequence method.
Allocate Plotfile name using selected sequence method after
deleting previously generated files.

SWITCH POSITION 3-5 Drawing sheet numbering.


0
x

First sheet commences at drawing number 1.


First sheet commences at drawing number x+1.

Switch Layout

3-5

1
Switch
Position

0
Number or 1
Blank or 1

0 or value

Related Program Development Specs.


8.13.0 RELEASE NOTES

First
Introduced

Related Option Switches.


O.S. 1 O.S. 36 O.S. 37 O.S. 69 O.S. 71

Extended
Use

Version

Date

1.0

APR 83

8.7.0 APR 01
8.10.0 MAY 02
8.13.0 SEP 06

OPT - 31

Details
Switches
by number
Switches
by name

- 46 -

ALIAS

32. Drawing output - scaling

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING OUTPUT - SCALING

32

Description

This Option Switch permits the increase or decrease of the final plotted
isometric size and thus change it from that defined by Option Switches 14, or
15 & 16.

Switch Settings

0 or 100

For No Scaling change (100% of set size).


This generates isometrics at the size set in either Option Switch
14, or a combination of Option Switches 15 & 16.

Value

Where Value is set to increase or decrease the final isometric


size in the ratio Value / 100.
e.g. Value = 71 would generate a Reduced size drawing at 71%
of the set size, (for example A2 reduced to A3).
Value = 120 would generate an Increased size drawing at
120% of the set size.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
VERSION 6.0 RELEASE NOTES.

First
Introduced

Related Option Switches.

Extended
Use

14

15

16

Version

Date

1.0

APR 83

6.0

MAR 91

Details

OPT - 32
Switches
by number
Switches
by name

- 47 -

ALIAS

33. Revision/detailed marker

Options

ISOGEN
Switch Title

Option Switch No.

33

REVISION / DETAILED MARKER


Description

This Option Switch is used by some 3D Design Systems to control the


updating of their 'Pipe Detailed' and / or 'Pipe Revision' database attribute
fields on the successful production of a pipeline isometric by ISOGEN.
Note. This Option Switch has no effect on any output generated by the
ISOGEN system.
Switch Settings

Default to Suppress the updating of both the Revision & Detailed


indicators.

For both the Revision and Detailed fields to be updated.

For Revision only to be updated.

For Detailed only to be updated.

Switch Layout

Switch
Position

All
Settings
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

1.0

APR 83

OPT - 33

Switches
by number
Switches
by name

- 48 -

ALIAS

34. Drawing output - Picture scale

Options

ISOGEN
Switch Title

Option Switch No.

34

DRAWING OUTPUT - PICTURE SCALE


Description

Used to increase or decrease the Scale of the pipeline 'picture' part of the
isometric only, while leaving all other parts (that is, Drawing Frame,
Material List, Title Block and Line Summary areas) un-altered.
By use of this Option Switch the whole of the pipeline picture and all text
pointing to it may be re-scaled to make it larger or smaller.

Switch Settings

0 or 100

Default to give the normal Picture Scaling. (100%).

Value

Where Value is set to increase or decrease the Scaling effect in


the ratio Value / 100.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

1.0

APR 83

Details

OPT - 34

Switches
by number
Switches
by name

- 49 -

ALIAS

35. Drawing - Reserved areas

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING - RESERVED AREAS

35

Description

This Option Switch may be used to create two Reserved 'No Go' areas
across the bottom part of the isometric. One is across the bottom of the
drawing region itself, while the other is across the bottom of the Material
List. Once set, ISOGEN will not automatically plot any information in
these areas. They are basically reserved areas on the Drawing Frame for
the inclusion on the finished drawing of related Project / Pipeline
information. The Frame Text Positioning facility may be used to add
information that is included in the Pipeline input data file in these areas.
This Option Switch is in two parts.
SWITCH POSITIONS 1, 2 & 3 - Reserved Area within the Drawing Region.
0
Default for No Reserved Area.
Value
Where Value is equal to the depth of the required Reserved
Area along the bottom of the isometric, measured in whole
mm.'s up from the outer line of the drawing frame.
SWITCH POSITIONS 4, 5 & 6 - Reserved Area at the bottom of the
Material List.
Blank
Default for No Reserved Area.
Value
Where Value is equal to the depth of the required Reserved
Area along the bottom of the Material List measured in whole
mm.'s up from the outer line of the drawing frame.

Switch Settings

SWITCH POSITION 7, 8 & 9 - Reserved Area in mms


X

Reserved area in mms.

Switch Layout

Switch
Position

X in mms

Blank or
Value

Zero or
Value
Version

Date

DEV. NO. 56 - USER DEFINED MATERIAL LIST. First


Introduced

1.0

APR 83

Related Option Switches.

7.0

OCT 94

Related Program Development Specs.

Extended
Use

13

Details

OPT - 35

Switches
by number
Switches
by name

- 50 -

ALIAS

36. Drawing output - Stacking value

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING OUTPUT - STACKING VALUE

36

Description

This Option Switch controls the number of Drawing Stacking rows within a
plot file containing multi-drawings.
Depending upon the drawing size, orientation, and width of the plotter
paper, Drawing Stacking may be one, two, three or more rows high.

Switch Settings

0 or 1

Default for 1 drawing high Stacking.


All drawings will be plotted side-by-side within the plotfile.

Value

Where Value is an alternative setting.


e.g. 2 for 2 frame high Stacking, 3 for 3 frame high, etc.

Note. This Option Switch must be set to 0 or 1 when using the Output to
graphics screen facility.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
First
Introduced

NONE
Related Option Switches.

31

Version

Date

1.0

APR 83

Extended
Use

37

Details

OPT - 36
Switches
by number
Switches
by name

- 51 -

ALIAS

37. Drawing output - Stacking orientation

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING OUTPUT STACKING ORIENTATION

37

Description

This Option Switch controls the Orientation of the drawings within the
plotfile.
If required, to make the most economical use of plotter paper, Drawings
may be set to run Along or Across the paper.
(Along being defined as running the length of the roll of plotter paper).
Switch Settings

Default for plotting Along the roll of paper .

For plotting Across the roll of paper .

Switch Layout

Switch
Position

Either
Setting
Related Program Development Specs.
NONE

First
Introduced

Related Option Switches.

Extended
Use

36

Version

Date

1.0

APR 83

Details

OPT - 37

Switches
by number
Switches
by name

- 52 -

ALIAS

38. Pipeline splitting - Automatic

Options

ISOGEN
Switch Title

Option Switch No.

38

PIPELINE SPLITTING - AUTOMATIC


Description

Controls Automatic Pipeline Splitting.


The amount of piping information that can be accommodated on a single
drawing is limited. Once the limit is exceeded, then pipeline splitting
automatically occurs.
By use of this Option Switch, users may either increase the information
content on each drawing , or alternatively, reduce the content.
Format of Drawing continuation messages.
Continuation graphics at the ends of spool isometric drawings.
Switch Settings

Switch Position 1 to 3 - Drawing information content limit


0 or 100

Default for what ISOGEN considers to be the limit for


drawing information content. The limit is set within the
program and varies for each size of drawing.

Value

Where value is set to increase or decrease the drawing


information content in the ratio Value / 100.

Switch Layout

Switch
Position

Zero or value
Related Program Development Specs.
8.13.0 RELEASE NOTES

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

1.0

APR 83

8.11.0

APR 03

8.13.0

SEP 06

OPT - 38

Details
Switches
by number
Switches
by name

- 53 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

38

PIPELINE SPLITTING - AUTOMATIC


Switch Settings

Switch Position 4 Drawing Continuation Message


0
1
2
3
4

Standard Drawing Continuation Message.


Drawing Continuation Message includes Pipeline Name.
Drawing Continuation to use PIPELINE-DRAWINGSEQUENCE-NUMBER (-90).
Drawing Continuation to use CLIENT-DRAWINGIDENTIFIER(-92).
Drawing Continuation to use SPOOL-DRAWINGSEQUENCE-NUMBER (-91).
Note. 4 applies to spool isometrics only.

Switch Position 5 Continuations at the ends of spool drawings


0
Value

Continuation Graphics not shown on Spool Isometrics.


Continuation Graphics shown on Spool Isometrics.

Version

Related Program Development Specs.


9.0.0 RELEASE NOTES

First
Introduced

Related Option Switches.

Extended
Use

9.0.0

Date

MAY08

Details

OPT - 38

Switches
by number
Switches
by name

- 54 -

ALIAS

39. Spool piece identifiers

Options

ISOGEN
Switch Title

Option Switch No.

SPOOL PIECE IDENTIFIERS

39

Description

Spool Identifiers permit the unique identification of each pipe Spool on the
isometric drawing.
There are several different formats available, as listed below.
Note. The presence of a record in a Pipeline Dat file to denote a User defined
Spool Identifier causes the value in Positions 1 & 2 of this Option Switch to
be totally ignored.
An additional control allows various box enclosures for the Spool Identifier.
Control whether Unions should be a spool split point.
This Option Switch is in 7 parts.

Switch Settings

SWITCH POSITION 1 - Basic control.


0

Default for Spool Identifiers to be switched On, using a


numeric system.
Causes the output of Spool Identifiers to be suppressed.
As for value 0 but use an alpha system of A, B, C etc.

1
2

(Continued overpage)
Switch Layout

All
Settings

Zero
or one

All
Settings

Zero
or one

All Zero
Settings or one

Related Program Development Specs.


DEV. NO. 48 - ISOMETRIC REPEATABILITY.
VERSION 7.0 - RELEASE NOTES.
VERSION 8.8.0 - RELEASE NOTES
DEV. NO. 89H - MESSAGE ENCLOSURES
ELLIPSES & DOUBLE CIRCLES
Related Option Switches.

ISSUE 3

First Use
Extended
Use

Switch
Position

All
Settings

Version

Date

1.0

APR 83
JUN 94
DEC 95
JAN 98

7.1
7.12
7.4
7.14.5
8.5.1
SEP 00
8.8.0 JUL 01
8.10.0 MAY 02

OPT - 39

- 55 -

Details
Switches
by number
Switches
by name

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

SPOOL PIECE IDENTIFIERS


Switch Settings

39 Cont.
(Continued from previous page)

SWITCH POSITION 2 - Spool Identifier sequence.


0
1

For the current Spool Identifier sequence to continue onto


each new drawing.
Causes Spool Identifiers to re-commence at 1 on each new
drawing.

SWITCH POSITION 3 - Box enclosure style.


0
1
2
3
4
5
6
7
9

Default for Spool Identifiers to be enclosed in the standard


square brackets or a Double box enclosure.
Enclosure to be a Diamond ended box.
Enclosure to be a Round ended box.
Enclosure to be a Triangle shaped box. *
Enclosure to be a Diamond shaped box. *
Enclosure to be a Square ended box.
Enclosure to be circular.
No enclosure.
Elliptical Spool Number enclosure.

* Because these two enclosures cannot be elongated there is a limit on the


number of characters that can be accommodated, depending upon
character size.
SWITCH POSITION 4 - Spool Drawing Identifier (User).
0
1

Default for Pipeline reference to be prefixed to Spool ID.


Output for Spool Drawing Identifier to be Pipeline Reference
- User Spool ID if any User Defined Spool IDs are found in
the input pipeline data file.

Details

ISSUE 3

OPT - 39

Switches
by number
Switches
by name

- 56 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

SPOOL PIECE IDENTIFIERS


Switch Settings

39 Cont.
(Continued from previous page)

SWITCH POSITION 5 - Spool Drawing Identifier (Automatic).


0
1

Spool Drawing Identifier to be Spool ID.


Output for Spool Drawing Identifier to be Pipeline Reference
- Automatic Spool ID if no User defined Spool IDs are found
in the input pipeline data file.
Spool Identifier generated from Pipeline File Name
- Automatic Spool ID

SWITCH POSITION 6 - Spool Identifiers (Fabrication).


0
1
2

Do not allocate Spool Identifiers for lone fabrication


components.
Allocate Spool Identifiers for lone fabrication components.
User controlled Pipe Spools only - no automatically
generated spools.

SWITCH POSITION 7 - Spool Break Points at Unions


0
1

A Fabrication union connecting fabrication components will


create separate spools.
A Fabrication union connecting fabrication
components will not create separate spools.

SWITCH POSITION 8 - Single/Double line Circular Spool Number


Enclosures
0
1

Single line Spool Number Enclosure.


Double line Spool Number Enclosure (use with circular
enclosure to get double circles).

SWITCH POSITION 9 - Circular & Elliptical Spool Number Enclosure


Size
0
Spool Number circular or elliptical enclosures fixed to 2
characters.
1 to 8
Spool Number circular or elliptical enclosures fixed to value
set.
9
Spool Number circular or elliptical enclosures variable sizes.
Extended
Use

ISSUE 3

8.11.0

APR 03

OPT - 39

Details
Switches
by number
Switches
by name

- 57 -

ALIAS

40. Pipe supports

Options

ISOGEN
Switch Title

Option Switch No.

40

PIPE SUPPORTS
Description

This Option Switch controls the following Pipe Support functions :a) Support Dimension type String, Overall, Included dimensions.
b) Whether or not Pipe Supports are shown on the isometric.
c) Support Dimension Stand-Out position. The Support Dimension may
either be on the same side of the pipe as the normal pipe dimensions, or
on the opposite side.
d) The Support Dimension Line Stand-Out distance.
e) Category of Supports to be dimensioned.
Switch Settings

This Option Switch is in six parts.

SWITCH POSITION 1 Pipe Support dimension type and support


suppression.
0
1
2
3
6

Default for Pipe supports to be drawn on the isometric and


dimensioned in string form.
For Pipe supports to be drawn on the isometric and dimensioned in
Overall form.
To suppress Pipe supports on the isometric and on the Material
list.
For Pipe supports to be drawn on the isometric but to be undimensioned.
For Pipe supports to be drawn on the isometric and for support
dimensions to be included with pipeline dimensions.

Switch Layout

Zero or one

Blank or
Value

Switch
Position

All
Settings
Version

Related Program Development Specs.


DEV. NO. 53 ISOPLOT PROGRAM UPDATE.
Related Option Switches.

First
Introduced
Extended
Use

O.S.
8 8 O.S.99

Date

1.0

APR 83

6.0

MAR 91

95 91
7.4 6.0 DECMAR

Details

ISSUE 3

OPT - 40
Switches
by number
Switches
by name

- 58 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

PIPE SUPPORTS

40 Contd.

Description

Switch Settings

(Contd. from previous page)

SWITCH POSITION 2 - Support Dimension Position.


0 or blank Default for Support Dimensions to be drawn on the same side of
the pipe as the normal dimensions.
Support Dimensions drawn on the opposite side of the pipeline
1
to the normal dimensions. (This causes any Dimension Line
Stand-Out Distance set in Switch Positions 3&4 to be ignored).
SWITCH POSITIONS 3 & 4 - Support Dimension Line Stand-Out Distance.
0 or blank No Support Dimension Line Stand-Out Distance set. Program
default will be used for all Support Dimensions.
Value equals the required Support Dimension Line Stand-Out
Value
Distance in whole mm.'s.

Switch Layout

Related Program Development Specs.


DEV. NO. 93G PIPE DIMENSIONS
INCLUDING SUPPORTS
Related Option Switches.

Version
First
Introduced
Extended
Use

ISSUE 3

Date

8.13.1 MAY 07

Details

OPT - 40
Switches
by number
Switches
by name

- 59 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

PIPE SUPPORTS

40 Contd.

SWITCH POSITION 5 - Selective Support Dimensioning.


Blank
1
2
3
4

Dimension All supports.


Dimension Fabrication type Supports ONLY.
Dimension Erection type Supports ONLY.
Dimension Offshore type Supports ONLY.
Dimension Erection & Offshore type Supports ONLY.

SWITCH POSITION 6 - Associated Additional Materials on Supports Weights.


0

Use weight of Associated Additional Materials on Supports in


calculations.
Ignore weight of Associated Additional Materials on
Supports in calculations.

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

7.14

MAR 98

Details

ISSUE 3

OPT - 40
Switches
by number
Switches
by name

- 60 -

ALIAS

41. Bore/Dimension/Weight Control

Options

ISOGEN
Switch Title

Option Switch No.

BORE / DIMENSION / WEIGHT


CONTROL

41

Description

Various combinations of Bore, Dimensional Units and Dimension Styles


(including Stacked Fractions) are available, as defined below.
There is also a control to determine how the numeric part of a metric coordinate is formatted.
Finally, this switch is also used for component weight output control.
Weight per unit length can be specified in different units to those used on
the isometric.
Notes.
The pipeline input file must be in the units specified in this Option Switch.
1) Units for Bore and Weight data included in the input pipeline data file
are set in Option Switch 65.
2) Bolt Length and Bolt Diameter units set in this Option Switch may be
changed by using Option Switch 65.
Switch Settings

This Option Switch is in eight parts.


SWITCH POSITION 1 - Dimensional units type.
0

Default, Inch pipeline bores and mm linear dimensions


(known as Mixed or SI units).
Inch pipeline bores and Feet & Inch linear dimensions
(known as Imperial units).
mm pipeline bores and mm linear dimensions
(known as Metric units).
Mm pipeline bores and Feet and Inch linear dimensions
(Mixed units).

1
2
3

Switch Layout

Switch
Position

All
Settings
Related Program Development Specs.

DEV. NO. 61 - WEIGHT FACILITY.


First
DEV. NO. 64 - EXTERNAL WEIGHT / C of G. Introduced
DEV.NO. 83F - DIMENSIONING
ENHANCEMENTS
Extended
Use

Related Option Switches.

O.S. 65

Version

Date

1.0

APR 83

7.0
7.2

OCT 93
APR 95

7.4

DEC 95

7.17.7 MAY 99
8.5.4

ISSUE 2

DEC 00

OPT - 41

- 61 -

Details
Switches
by number
Switches
by name

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

BORE / DIMENSION / WEIGHT


CONTROL
Switch Settings

41 Cont.

(Continued from previous page)

SWITCH POSITION 2 - Co-ordinate Output format (for Metric


co-ordinates only).
0
1
2
3

For Metric dimensions/co-ordinates output in mm.


For Metric co-ordinates output in M.mm format.
For Metric dimensions output in M.mm format
For Metric dimensions/co-ordinates in M.mm format.

SWITCH POSITION 3 - Feet-Inch output & Stacked Fractions .


0
1
2

3
4
5
6
7
8

For standard output of FT INS dimensions


- of the form 6 10. 3/8
Same as value 0 but with an added dash
- of the form 6 - 10.3/8
Same as value 1 but with a blank space instead of a dot (.)
between inches and fractions of an inch of the form 6 - 10 3/8
Stacked Fractions with a dash - of the form 6 - 103/8"
3
Stacked Fractions without a dash - of the form 6 10 /8"
Output decimal inches to 1 decimal place.
Output decimal inches to 2 decimal places.
Output decimal inches to 3 decimal places.
Output decimal inches to 4 decimal places.

Switch Layout

Version

Related Program Development Specs.

DEV. 91D UNIT CONVERSION

First
Introduced

Related Option Switches.

Extended
Use

Date

8.11.0 APR 03
8.13.0 SEP 06

OPT - 41

ISSUE 2

Switches
by number
Switches
by name

- 62 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

BORE / DIMENSION / WEIGHT


CONTROL
Switch Settings

41 Cont.

(Continued from previous page)

SWITCH POSITION 4 - Weight Information Output / Weight Units.


0

1
2
3
4
5
6

Default for NO Weight information to be output.


(This applies to ALL outputs I.e. Material Lists, Weight output on
Drawing Frame, Material Control Files, etc.).
All Weights - Input / Output to be in Kilograms (KGS).
All Weights - Input / Output to be in Pounds (LBS).
All Weights - Input / Output to be in Kilograms / Metre (KGS/M).
All Weights - Input / Output to be in Pounds / Metre (LBS/M).
All Weights - Input / Output to be in Kilograms / Foot (KGS/FT).
All Weights - Input / Output to be in Pounds / Foot (LBS/FT).

SWITCH POSITION 5 - Component Weight Output


0 or Blank
1
2

Default for NO Component Weight output on Material List.


Any Component Weight output will be a Total Weight (I.e.
Quantity x Unit Weight).
Any Component Weight output will be the individual
Weight of each component type (i.e. No multiplication x
Quantity).

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

OPT - 41

ISSUE 2

Switches
by number
Switches
by name

- 63 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

BORE / DIMENSION / WEIGHT


CONTROL
Switch Settings

41 Cont.

(Continued from previous page)

SWITCH POSITIONS 6 & 7 - Imperial Dimension Output Format


(Inches or Feet-Inches)
0
1
Value

For program to change dimensioning from INCHES to


FEET-INCHES at 24.
For dimensions to be output in INCHES.
The value is set to a number of whole inches at which output
style changes from INCHES to FEET-INCHES.
Valid input is 12 or greater.

SWITCH POSITION 8 - Suppression of Bore (N.S.) output at Branch


(Tee / Olet / Cross) and Reducer locations
0
1

N.S. information output at Branches & Reducers as normal.


N.S. information output at Branches & Reducers to be
suppressed.

SWITCH POSITION 9 - Nominal size output separately on pipe section for


set-on-tee and crosses
Blank
1

N.S. output at set-on-tee and crosses combined


N.S. output at set-on-tee and crosses shown separately

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

OPT - 41

ISSUE 2

Switches
by number
Switches
by name

- 64 -

ALIAS

42. Drawing viewpoint

Options

ISOGEN
Switch Title

Option Switch No.

DRAWING VIEWPOINT

42

Description

This Option Switch controls the Viewing Direction (isometric orientation).


There are four orientation options which may be chosen by the User and
the selected one is indicated on the isometric by the direction the North
Arrow is pointing.
A secondary use of the Option Switch permits the User to request the North
arrow to be highlighted by an enclosing box.
Switch Settings

Default for North Arrow to point Top Left.

For North Arrow to point Bottom Right.

For North Arrow to point Top Right.

For North Arrow to point Top Left.

For North Arrow to point Bottom Left.

For North Arrow to point Bottom Right with enclosing box.

For North Arrow to point Top Right with enclosing box.

For North Arrow to point Top Left with enclosing box.

For North Arrow to point Bottom Left with enclosing box.

Switch Layout

Switch
Position

All
Settings
Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

Details

OPT - 42
Switches
by number
Switches
by name

- 65 -

ALIAS

43. Pipe wastage factor - Area 1

Options

ISOGEN
Switch Title

Option Switch No.

PIPE WASTAGE FACTOR - AREA 1

43

Description

Controls any additional Pipe quantity that needs to be added to the Material
List to allow for Wastage during fabrication.
The Option Switch is one of nine that holds a percentage factor that is used
to calculate pipe Wastage allowances.
Each of the nine Option Switches is applicable to a particular Plant Area
which can be identified in the Pipeline Input Data File.
Switch Settings

This Option Switch is for Pipe Wastage in Plant Area 1.

For a percentage multiplication factor of zero.


(This setting allows the User to obtain NO increase in Pipe
material quantity even though a value may have been included
in the Pipeline Data Input File).

Default for a percentage multiplication factor of 1.


(This value does Not increase the Basic Wastage percentage that
may be set in applicable records in the Pipeline Input Data File).

Value

Where Value is an additional factor that is multiplied by the


Basic Wastage Factor (input on appropriate records in the
Pipeline Data Input File) to arrive at a final Wastage Factor
percentage. (e.g. A value of 2 in this Option Switch would give a
final percentage of twice the value of any figure included in
the Pipeline Data Input File).

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.
O.S. 4445
to O.S.
44
4651 inclusive.
47 48

49

50

51

1.0

Date

APR 83

Extended
Use

Details

OPT - 43
Switches
by number
Switches
by name

- 66 -

ALIAS

44. Pipe wastage factor - Area 2

Options

ISOGEN
Switch Title

Option Switch No.

PIPE WASTAGE FACTOR - AREA 2

44

Description

Controls any additional Pipe quantity that needs to be added to the Material
List to allow for Wastage during fabrication.
The Option Switch is one of nine that holds a percentage factor that is used
to calculate pipe Wastage allowances.
Each of the nine Option Switches is applicable to a particular Plant Area
which can be identified in the Pipeline Input Data File.
Switch Settings

This Option Switch is for Pipe Wastage in Plant Area 2.

For a percentage multiplication factor of zero.


(This setting allows the User to obtain NO increase in Pipe
material quantity even though a value may have been included
in the Pipeline Data Input File).

Default for a percentage multiplication factor of 1.


(This value does Not increase the Basic Wastage percentage that
may be set in applicable records in the Pipeline Input Data File).

Value

Where Value is an additional factor that is multiplied by the


Basic Wastage Factor (input on appropriate records in the
Pipeline Data Input File) to arrive at a final Wastage Factor
percentage. (e.g. A value of 2 in this Option Switch would give a
final percentage of twice the value of any figure included in
the Pipeline Data Input File).

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.
O.S. 4345
and O.S.
to O.S.48
51 inclusive.
43
46 45 47
49 50

51

1.0

Date

APR 83

Extended
Use

Details

OPT - 44

Switches
by number
Switches
by name

- 67 -

ALIAS

45. Pipe wastage factor - Area 3

Options

ISOGEN
Switch Title

Option Switch No.

PIPE WASTAGE FACTOR - AREA 3

45

Description

Controls any additional Pipe quantity that needs to be added to the Material
List to allow for Wastage during fabrication.
The Option Switch is one of nine that holds a percentage factor that is used
to calculate pipe Wastage allowances.
Each of the nine Option Switches is applicable to a particular Plant Area
which can be identified in the Pipeline Input Data File.
Switch Settings

This Option Switch is for Pipe Wastage in Plant Area 3.

For a percentage multiplication factor of zero.


(This setting allows the User to obtain NO increase in Pipe
material quantity even though a value may have been included
in the Pipeline Data Input File).

Default for a percentage multiplication factor of 1.


(This value does Not increase the Baisic Wastage percentage that
may be set in applicable records in the Pipeline Input Data File).

Value

Where Value is an additional factor that is multiplied by the


Basic Wastage Factor (input on appropriate records in the
Pipeline Data Input File) to arrive at a final Wastage Factor
percentage. (e.g. A value of 2 in this Option Switch would give a
final percentage of twice the value of any figure included in
the Pipeline Data Input File).

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Related Option Switches.

Extended
O.S. 4344
and O.S.
and O.S.
43
46 44 47
4846 to49O.S. 5150inclusive.
51 Use

Details

OPT - 45
Switches
by number
Switches
by name

- 68 -

ALIAS

46. Pipe wastage factor - Area 4

Options

ISOGEN
Switch Title

Option Switch No.

PIPE WASTAGE FACTOR - AREA 4

46

Description

Controls any additional Pipe quantity that needs to be added to the Material
List to allow for Wastage during fabrication.
The Option Switch is one of nine that holds a percentage factor that is used
to calculate pipe Wastage allowances.
Each of the nine Option Switches is applicable to a particular Plant Area
which can be identified in the Pipeline Input Data File.
Switch Settings

This Option Switch is for Pipe Wastage in Plant Area 4.

For a percentage multiplication factor of zero.


(This setting allows the User to obtain NO increase in Pipe
material quantity even though a value may have been included
in the Pipeline Data Input File).

Default for a percentage multiplication factor of 1.


(This value does Not increase the Basic Wastage percentage that
may be set in applicable records in the Pipeline Input Data File).

Value

Where Value is an additional factor that is multiplied by the


Basic Wastage Factor (input on appropriate records in the
Pipeline Data Input File) to arrive at a final Wastage Factor
percentage. (e.g. A value of 2 in this Option Switch would give a
final percentage of twice the value of any figure included in
the Pipeline Data Input File).

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.
O.S. 4344
to O.S.
47 to O.S.
inclusive.
43
4545 and
47O.S.48
49 5150
51

1.0

Date

APR 83

Extended
Use

Details

OPT - 46
Switches
by number
Switches
by name

- 69 -

ALIAS

47. Pipe wastage factor - Area 5

Options

ISOGEN
Switch Title

Option Switch No.

PIPE WASTAGE FACTOR - AREA 5

47

Description

Controls any additional Pipe quantity that needs to be added to the Material
List to allow for Wastage during fabrication.
The Option Switch is one of nine that holds a percentage factor that is used
to calculate pipe Wastage allowances.
Each of the nine Option Switches is applicable to a particular Plant Area
which can be identified in the Pipeline Input Data File.
Switch Settings

This Option Switch is for Pipe Wastage in Plant Area 5.

For a percentage multiplication factor of zero.


(This setting allows the User to obtain NO increase in Pipe
material quantity even though a value may have been included
in the Pipeline Data Input File).

Default for a percentage multiplication factor of 1.


(This value does Not increase the Basic Wastage percentage that
may be set in applicable records in the Pipeline Input Data File).

Value

Where Value is an additional factor that is multiplied by the


Basic Wastage Factor (input on appropriate records in the
Pipeline Data Input File) to arrive at a final Wastage Factor
percentage. (e.g. A value of 2 in this Option Switch would give a
final percentage of twice the value of any figure included in
the Pipeline Data Input File).

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.
O.S. 4344
to O.S.
48 to O.S.
inclusive.
43
4546 and
46O.S.48
49 5150
51

1.0

Date

APR 83

Extended
Use

Details

OPT - 47
Switches
by number
Switches
by name

- 70 -

ALIAS

48. Pipe wastage factor - Area 6

Options

ISOGEN
Switch Title

Option Switch No.

PIPE WASTAGE FACTOR - AREA 6

48

Description

Controls any additional Pipe quantity that needs to be added to the Material
List to allow for Wastage during fabrication.
The Option Switch is one of nine that holds a percentage factor that is used
to calculate pipe Wastage allowances.
Each of the nine Option Switches is applicable to a particular Plant Area
which can be identified in the Pipeline Input Data File.
Switch Settings

This Option Switch is for Pipe Wastage in Plant Area 6.

For a percentage multiplication factor of zero.


(This setting allows the User to obtain NO increase in Pipe
material quantity even though a value may have been included
in the Pipeline Data Input File).

Default for a percentage multiplication factor of 1.


(This value does Not increase the Basic Wastage percentage that
may be set in applicable records in the Pipeline Input Data File).

Value

Where Value is an additional factor that is multiplied by the


Basic Wastage Factor (input on appropriate records in the
Pipeline Data Input File) to arrive at a final Wastage Factor
percentage. (e.g. A value of 2 in this Option Switch would give a
final percentage of twice the value of any figure included in
the Pipeline Data Input File).

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.
O.S. 4344
to O.S.
49 to O.S.
inclusive.
43
4547 and
46O.S.47
49 5150
51

1.0

Date

APR 83

Extended
Use

Details

OPT - 48
Switches
by number
Switches
by name

- 71 -

ALIAS

49. Pipe wastage factor - Area 7

Options

ISOGEN
Switch Title

Option Switch No.

PIPE WASTAGE FACTOR - AREA 7

49

Description

Controls any additional Pipe quantity that needs to be added to the Material
List to allow for Wastage during fabrication.
The Option Switch is one of nine that holds a percentage factor that is used
to calculate pipe Wastage allowances.
Each of the nine Option Switches is applicable to a particular Plant Area
which can be identified in the Pipeline Input Data File.
Switch Settings

This Option Switch is for Pipe Wastage in Plant Area 7.

For a percentage multiplication factor of zero.


(This setting allows the User to obtain NO increase in Pipe
material quantity even though a value may have been included
in the Pipeline Data Input File).

Default for a percentage multiplication factor of 1.


(This value does Not increase the Basic Wastage percentage that
may be set in applicable records in the Pipeline Input Data File).

Value

Where Value is an additional factor that is multiplied by the


Basic Wastage Factor (input on appropriate records in the
Pipeline Data Input File) to arrive at a final Wastage Factor
percentage. (e.g. A value of 2 in this Option Switch would give a
final percentage of twice the value of any figure included in
the Pipeline Data Input File).

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.
O.S. 4344
to O.S.
50 and48
O.S. 51
43
4548 and
46O.S.47
50inclusive.
51

1.0

Date

APR 83

Details

Extended
Use

OPT - 49

Switches
by number
Switches
by name

- 72 -

ALIAS

50. Pipe wastage factor - Area 8

Options

ISOGEN
Switch Title

Option Switch No.

PIPE WASTAGE FACTOR - AREA 8

50

Description

Controls any additional Pipe quantity that needs to be added to the Material
List to allow for Wastage during fabrication.
The Option Switch is one of nine that holds a percentage factor that is used
to calculate pipe Wastage allowances.
Each of the nine Option Switches is applicable to a particular Plant Area
which can be identified in the Pipeline Input Data File.
Switch Settings

This Option Switch is for Pipe Wastage in Plant Area 8.

For a percentage multiplication factor of zero.


(This setting allows the User to obtain NO increase in Pipe
material quantity even though a value may have been included
in the Pipeline Data Input File).

Default for a percentage multiplication factor of 1.


(This value does Not increase the Basic Wastage percentage that
may be set in applicable records in the Pipeline Input Data File).

Value

Where Value is an additional factor that is multiplied by the


Basic Wastage Factor (input on appropriate records in the
Pipeline Data Input File) to arrive at a final Wastage Factor
percentage. (e.g. A value of 2 in this Option Switch would give a
final percentage of twice the value of any figure included in
the Pipeline Data Input File).

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.
O.S. 43
51 inclusive.
43
44to O.S.
4549 and
46O.S.47
48 49

51

1.0

Date

APR 83

Details

Extended
Use

OPT - 50

Switches
by number
Switches
by name

- 73 -

ALIAS

51. Pipe wastage factor - Area 9

Options

ISOGEN
Switch Title

Option Switch No.

PIPE WASTAGE FACTOR - AREA 9

51

Description

Controls any additional Pipe quantity that needs to be added to the Material
List to allow for Wastage during fabrication.
The Option Switch is one of nine that holds a percentage factor that is used
to calculate pipe Wastage allowances.
Each of the nine Option Switches is applicable to a particular Plant Area
which can be identified in the Pipeline Input Data File.
Switch Settings

This Option Switch is for Pipe Wastage in Plant Area 9.

For a percentage multiplication factor of zero.


(This setting allows the User to obtain NO increase in Pipe
material quantity even though a value may have been included i
n the Pipeline Data Input File).

Default for a percentage multiplication factor of 1.


(This value does Not increase the Basic Wastage percentage that
may be set in applicable records in the Pipeline Input Data File).

Value

Where Value is an additional factor that is multiplied by the


Basic Wastage Factor (input on appropriate records in the
Pipeline Data Input File) to arrive at a final Wastage Factor
percentage. (e.g. A value of 2 in this Option Switch would give a
final percentage of twice the value of any figure included in
the Pipeline Data Input File).

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.
O.S. 4344
to O.S.
43
4550 inclusive.
46 47

48

49

50

1.0

Date

APR 83

Extended
Use

Details

OPT - 51

Switches
by number
Switches
by name

- 74 -

ALIAS

52. Equipment trim drawings

Options

ISOGEN
Switch Title

Option Switch No.

EQUIPMENT TRIM DRAWINGS

52

Description

This Option Switch controls the various functions (listed below) related to
the generation of Equipment Trim (Vessel Trim) drawings and associated
Material Control files.

Switch Settings

This Option Switch is in three parts.

SWITCH POSITION 1 - Part Number sequencing on the Material List.


0
Part Numbers starting at 1 for each Nozzle.
1
Parts sequentially numbered (starting at 1) for the whole
Material List.
SWITCH POSITION 2 - Material Control File content for Equipment Trim
entries.
0 or blank All components related to a single Equipment Item
accumulated and written to the Material Control file under
a single 'Pipeline' entry.
Equipment Trim Reference is used as the 'Pipeline Reference'
for identification purposes.
1
Components for each Nozzle kept separate and written to the
Material Control file using the individual Pipeline Reference
associated with each Nozzle.
(Continued overpage)

Switch Layout

Switch
Position

Blank or Zero, blank


one
or one

Either
Setting
Version

Related Program Development Specs.


DEV. NO. 34 - EQUIPMENT TRIM FACILITY.

First
Introduced

5.8

Date

MAY 89

Extended
Use

Details

OPT - 52

Switches
by number
Switches
by name

- 75 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

EQUIPMENT TRIM DRAWINGS

52 Cont.

Description

Switch Settings

(Continued from previous page)

SWITCH POSITION 3 - Style of Input Data File.


0

Single Pipeline type file (where there is only one set of Header
Records).

Multiple Pipeline type file (where there are Multiple sets of Header
Records).

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

Details

OPT - 52
Switches
by number
Switches
by name

- 76 -

ALIAS

53. Weld numbering

Options

ISOGEN
Switch Title

Option Switch No.

WELD NUMBERING

53

Description

Controls aspects related to the Weld Numbering function, thus:i)


Text Size.
ii)
Type of Welds that are to be numbered on the isometric.
iii)
Whether or not to plot a Weld Box / Operations Box.
iv)
Weld numbering sequence where multi-drawings for a pipeline
are produced.
v)
Individual Weld numbering by category.
vi)
Support Weld numbering sequence.
This Option Switch is in seven parts.
SWITCH POSITION 1 - Weld Number text size & Weld type to be numbered.
0
Default for No Weld Numbers.
1
For Small size Weld Numbers 1.5mm high.
2
For Medium size Weld Numbers 1.8mm high.
3
For Large size Weld Numbers 2.1mm high.
4
To number only Fabrication type welds - Small size.
5

- Medium size.
6

- Large size.
7
To number only Erection type welds - Small size.
8

- Medium size.
9

- Large size.
Notes.
1) All the above size values are only valid when Weld Numbers are being
plotted in the original circular style enclosures.
2) This Option Switch Position should be set to value 0, 1, 2 or 3 if Position
4 is set to value 0 or 1.
(Continued over page)
Switch Settings

All
Settings

Switch Layout

Related Program Development Specs.


DEV. NO. 57 - WELDING UPGRADE.
DEV. NO. 58 - ISO REPEATABILITY STAGE II.
DEV. NO. 74D - SUPPORT WELD PREFIX AND
NUMBERING SEQUENCES
Related Option Switches.

54

75

Switch
Position

77

Version

Date

First
Introduced

1.0

APR 83

Extended
Use

7.0

OCT 93

7.4
DEC 95
7.16.0 MAY 99

Details

8.11.0 APR 03

OPT - 53

ISSUE 2

Switches
by number
Switches
by name

- 77 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

WELD NUMBERING
Switch Settings

53 Cont.

(Continued from previous page)

SWITCH POSITION 2 - Weld Box / Operations Box generation.


0
Default for No Weld / Operations Box.
1
For Weld Box Summary to be plotted.
2
For Operations Box Summary to be plotted / printed.
SWITCH POSITION 3 - Weld Number Sequence Control.
0
1
2

Default, weld number sequence to continue on


each new drawing.
Weld numbers to commence at start of each new drawing.
Spool isometric weld numbers to match full isometric weld
numbers when using continuous weld numbers across
drawings.
Spool isometric weld numbers to match full isometric weld
numbers when using the weld number sequence commencing
on each drawing.
Suppress the generation of weld numbers.

SWITCH POSITION 4 - Offshore Weld Number control.


0
1
2

Default to have Offshore Weld Numbers generated.


To Number Offshore Welds only.
Offshore Welds NOT to be Numbered.

Note

This Option Switch Position should be set to value 2 when


Position 1 is set to value 4, 5, 6, 7, 8 or 9.

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

Details

ISSUE 2

OPT - 53
Switches
by number
Switches
by name

- 78 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

WELD NUMBERING

53 Cont.

Description

Switch Settings

(Continued from previous page)

SWITCH POSITION 5 - Individual Weld Numbering sequences.


0 or Blank
1

Single sequence for all Welds.


Individual sequence for each Weld category.

SWITCH POSITION 6 - Support Weld sequences.


0
1
2

Use same sequence as that used for standard Welds.


Single sequence for all Support Welds.
Individual sequence for each Support Weld category.

SWITCH POSITION 7 - Support Weld Numbering sequences.


0
1

Support Weld sequence to continue on each new drawing.


Support Weld Numbers to commence at 1 on each new
drawing.

SWITCH POSITION 8 - Alphabetic Weld Identifiers generated


0
1

Numeric Weld Identifiers


Alphabetic Weld Identifiers

SWITCH POSITION 9 - Number of characters in the Weld Identifier


0
Value

No leading characters output before weld identifier


Minimum number of characters in a weld number.
Leading 0s will be added to attain Value set.

( Please note Position 8 & 9 cannot be used in conjunction with fixed size
weld enclosures, if requested they will automatically be changed to variable
size circular enclosure type.)

Details

ISSUE 2

OPT - 53
Switches
by number
Switches
by name

- 79 -

ALIAS

54. Weld plotting

Options

ISOGEN
Switch Title

Option Switch No.

54

WELD PLOTTING
Description

Controls which types of Welds are plotted on the isometric.


The various switch settings permit different types of Welds either to be
plotted or not, to suit the particular type of isometric being generated.
A further specialised option causes all program generated Site Welds to be
changed into Fabrication Welds.
Switch Settings

SWITCH POSITION 1 - Weld types and plotting options


0
1
2
3
4

Default to have all types of welds plotted.


To have all welds suppressed.
To have only Site welds plotted.
To have only Fabrication welds plotted.
To change Site welds generated by the program into
Fabrication welds. (This action does Not change user inserted
Site Welds).

Notes.
i)

Whenever this Option Switch is set to 1, 2 or 3, Option Switch


53 which controls Weld Numbering should be set to the same
requirements.

ii)

Whenever this option Switch is set to 4 to change Site welds


into Fabrication welds, the program will also change the type
of Weld numbers generated.

Switch Layout

Switch
Position

All Settings
Related Program Development Specs.
DEV NO. 89H - MESSAGE ENCLOSURES
ELLIPTICAL AND DOUBLE CIRCLES
8.13.0 RELEASE NOTES
DEV NO. 92E WELDING ENHANCEMENT 2
Related Option Switches.

Version
First
Introduced
Extended
Use

1.0

Date

APR 83

8.10.0 MAY 02
8.13.0 SEP 06

Details

O.S. 53 O.S. 75 O.S. 77 O.S. 78

ISSUE 2

OPT - 54
Switches
by number
Switches
by name

- 80 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

54 cont.

WELD PLOTTING
Switch Settings

SWITCH POSITION 2 - Weld Numbering - Circular or Elliptical


Enclosures for Fabrication Welds.
0
1 to 8
9

Weld Number circular or elliptical enclosures fixed to 2


characters.
Weld Number circular or elliptical enclosures fixed to value
set.
Weld Number circular or elliptical enclosures variable sizes.

SWITCH POSITION 3 - Weld Numbering Circular or Elliptical Enclosures


for Erection Welds.
0 / 1 to 8 / 9

As Switch Position 2 - see above.

SWITCH POSITION 4 - Weld Numbering Circular or Elliptical Enclosures


for Offshore Welds.
0 / 1 to 8 / 9

As Switch Position 2 - see above.

SWITCH POSITION 5 - Support Weld Numbering - Circular or Elliptical


Enclosures for Fabrication Welds.
0
to 2
1 to 8
9

Support Weld Number circular or elliptical enclosures fixed


characters.
Support Weld Number circular or elliptical enclosures fixed
to value set.
Support Weld Number circular or elliptical enclosures
variable sizes.

SWITCH POSITION 6 - Support Weld Numbering Circular or Elliptical


Enclosures for Erection Welds.
0 / 1 to 8 / 9

As Switch Position 5 - see above.

SWITCH POSITION 7 - Support Weld Numbering Circular or Elliptical


Enclosures for Offshore Welds.
0 / 1 to 8 / 9

As Switch Position 5 - see above.

SWITCH POSITION 8 Suppress generation of implied welds.


0
1

Generate welds at appropriate implied locations.


Suppress the generation of implied welds.

SWITCH POSITION 9 Arrows heads on weld messages


0
1

Output arrowheads on all weld messages.


Suppress arrowheads on all weld messages.

ISSUE 2

OPT - 54
Switches
by number
Switches
by name

- 81 -

ALIAS

55. Program messages - Run information

Options

ISOGEN
Switch Title

Option Switch No.

PROGRAM MESSAGES - RUN


INFORMATION

55

Description

This Option Switch controls the volume of data that is written to the
Message File (and to the screen during interactive processing) regarding
'Program Running and Plotfile Generation' information.

Switch Settings

SWITCH POSITION 1 - Running Information.


Default for minimum Running information. ISOGEN Program
0
version identification and Plot file generation messages are output.
1
As for 0 above with the addition of ISODAT and ISOPLOT
module running messages.
2
As for 1 above with the addition of information related to the
progress of the isometric through the ISOPLOT module.
SWITCH POSITION 2 - Disconnection Message.
0

Output Disconnection message local to pipeline break where


increased tolerance used to connect pipeline.

Suppression of local Disconnection message where increased


tolerance used to connect pipeline.

Switch Layout

Zero
or One

Switch
Position

All
Settings
Version

Related Program Development Specs.


First
Introduced

NONE
Related Option Switches.
O.S. 21

Extended
Use

Date

1.0

APR 83

7.16.0

MAY 99

OPT - 55

Running messages.

Switches
by number
Switches
by name

- 82 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

PROGRAM MESSAGES - RUN


INFORMATION

55 cont.

Description

Switch Settings

SWITCH POSITION 3 - Disconnected Pipeline.


0

Set pipeline to disconnected when increased tolerance used to


connect pipeline. Output of Disconnected Pipeline message at
top of drawing.

Suppresses Disconnected Pipeline message at top of drawing


if pipeline has connected using the increased tolerance
(message will always be output if pipeline does not connect
using increased tolerance).

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

OPT - 55
Switches
by number
Switches
by name

- 83 -

ALIAS

56. Program messages - Isodat

Options

ISOGEN
Switch Title

Option Switch No.

PROGRAM MESSAGES - ISODAT

56

Description

This Option Switch controls the output of program diagnostic information


to the Message File by the ISODAT program during processing.
Note. This Option Switch Is A Special Purpose One. It Should Not Be Set
By Users, Only By Alias System Support Personnel.
Switch Settings

Default for No diagnostic messages from ISODAT.

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 56
Switches
by number
Switches
by name

- 84 -

ALIAS

57. Program messages - Isoplot

Options

ISOGEN
Switch Title

Option Switch No.

PROGRAM MESSAGES - ISOPLOT

57

Description

This Option Switch controls the output of program diagnostic information


to the Message File by the ISOPLOT program during processing.
Note. This Option Switch Is A Special Purpose One. It Should Not Be Set
By Users, Only By Alias System Support Personnel.
Switch Settings

Default for No diagnostic messages from ISOPLOT.

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

Details

OPT - 57

Switches
by number
Switches
by name

- 85 -

ALIAS

58. Clear screen

Options

ISOGEN
Switch Title

Option Switch No.

CLEAR SCREEN

58

Description

This Option Switch is used to control the clearing of the graphics screen
when isometrics are sent to the screen rather than to a plot file.

Switch Settings

Default for No automatic Screen Clear.

Provides automatic clearing of the screen before showing the first


isometric.

Note.
With the introduction of modern Screen Drivers it is possible that a Clear
Screen operation will be performed automatically.
The setting of this Option Switch will have no effect in these cases,

Switch Layout

Switch
Position

Either
Value
Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

Details

OPT - 58

Switches
by number
Switches
by name

- 86 -

ALIAS

59. Instrument identification

Options

ISOGEN
Switch Title

Option Switch No.

INSTRUMENT IDENTIFICATION

59

Description

Controls which particular 3D Design System parameter is used by ISOGEN


for Instrument identification on the Material List or any Material Control
file that is generated.
Typically, 3D Design Systems have parameters for both the Instrument
Name (Tag) and the Specification Reference (Item Code), but only one of
these may be selected for output.
Switch Settings

Default for the Instrument Name (Tag) to be output.

For the Instrument's Specification Reference (Item Code) to be


output.

Switch Layout

Switch
Position

Either
Value
Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

Details

OPT - 59

Switches
by number
Switches
by name

- 87 -

ALIAS

60. Component tagging

Options

ISOGEN
Switch Title

Option Switch No.

COMPONENT TAGGING

60

Description

This Option Switch controls the plotting of Tags / Names on most pipeline
components.
'Tagging' of Pipe (Tube) and pipeline elements made from Pipe (Tube) is
not supported.
'Tagging' of Instruments is controlled by Option Switch 123.
Tags / Names may be switched On or Off to suit the users requirement.
A secondary option when plotting Tags / Names is to have the text boxed in
with a surrounding enclosure.
Switch Settings

SWITCH POSITION 1 Plotting of Component Names / Tags


0
1
2

Default for Tags / Names Not to be plotted.


To have Tags / Names plotted and boxed in.
To have Tags / Names plotted but Not boxed in.

SWITCH POSITION 3 Component Names / Tags enclosures


0
1
2
3
4
5
6
7
8

Square Ended Box Enclosure


Diamond Ended Box Enclosure
Round Ended Box Enclosure
Triangular Enclosure
Diamond Enclosure
Square Ended Box Enclosure
Circular Enclosure
Elliptical Enclosure
Hexagonal Enclosure

Switch Layout

Switch
Position

Settings
Related Program Development Specs.
DEV. NO. 32 - EXTENSION OF COMPONENT
NAMING FACILITY.
8.13.0 RELEASE NOTES
Related Option Switches

Version
First
Introduced
Extended
Use

123
O.S.
64 O.S. 123

Date

1.0

APR 83

5.5

FEB 88

8.13.0

SEP 06

OPT - 60

Details
Switches
by number
Switches
by name

- 88 -

ALIAS

61. Insulation indication

Options

ISOGEN
Switch Title

Option Switch No.

INSULATION INDICATION

61

Description

This Option Switch controls Insulation indication on the isometric in the


form of dashed lines plotted on each side of the pipe and optionally, around
components.
The feature may switched On or Off to suit the Users requirement.

Switch Settings

Default to have dashed Insulation lines plotted alongside pipeonly,


with a gap of 1 mm.

To Suppress Insulation indication.

To have dashed Insulation lines plotted alongside pipe and all


components, both with a 1 mm gap.

Note.
When Tracing is also shown, Insulation is only drawn on one side of the pipe.

Switch Layout

Switch
Position

All
Settings
Related Program Development Specs.
DEV. NO. 13 - INSULATION INDICATION ON
FITTINGS.
Related Option Switches.

Version
First
Introduced
Extended
Use

O.S.
6262

Date

1.0

APR 83

4.0

JUN 86

Details

OPT - 61
Switches
by number
Switches
by name

- 89 -

ALIAS

62. Tracing indication

Options

ISOGEN
Switch Title

Option Switch No.

TRACING INDICATION

62

Description

This Option Switch controls the plotting of Tracing indication on the


isometric in the form of a chain dotted line on one side of the pipe and
optionally, alongside components.
This may switched On or Off to suit the Users requirement.

Switch Settings

Default to have chain dotted Tracing lines plotted alongside pipe only,
with a gap of 1 mm.

To Suppress Tracing indication.

To have chain dotted Tracing lines plotted alongside pipe andall


components, both with a 1 mm gap.

Switch Layout

Switch
Position

All
Settings
Related Program Development Specs.
DEV. NO. 12 - TRACING INDICATION ON
FITTINGS.
Related Option Switches.

Version
First
Introduced
Extended
Use

O.S.
6161

Date

1.0

APR 83

4.0

JUN 86

Details

OPT - 62

Switches
by number
Switches
by name

- 90 -

ALIAS

63. Printed output - Page length

Options

ISOGEN
Switch Title

Option Switch No.

PRINTED OUTPUT PAGE LENGTH

63

Description

This Option Switch controls the number of lines per page on any Printed
Output (Reports) generated by the ISOGEN system.

Switch Settings

Default for 55 lines per page.

Value

Where Value is the required number of lines to be output per


page.

Switch Layout

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

Details

OPT - 63

Switches
by number
Switches
by name

- 91 -

ALIAS

64. Pipe support identification

Options

ISOGEN
Switch Title

Option Switch No.

PIPE SUPPORT IDENTIFICATION

64

Description

This Option Switch controls the identification information that is output for
Pipe Supports on the isometric and parts list.
For identification purposes, either the Support Name (Tag) or Specification
Reference (Item Code) may be used, in the combinations listed below.
A further option allows certain support information to be passed to the
COMDACE Material Control system.
COMDACE is a registered trademark of John Brown Systems Ltd.
Switch Settings

SWITCH POSITION 1 - Out put of Support Names (Tags).


0
No Support Names (Tags) to be output on the isometric and
with the Specification Reference (Item Code) output in the
Item Code field of the Material List.
1
For Support Names (Tags) to be output on the isometric
un-boxed and the Support Names output in the Item Code
field of the Material List
2
For Support Names (Tags) to be output on the isometric
boxed and the Specification Reference output in the Item
Code field of the Material List
3
As for Value 1 except Supports to be excluded from the
Material List.
4
As for Value 2 except Supports to be excluded from the
Material List
5
As for Value 0 except Supports to be excluded from the
Material List.
10
Causes Support Names (Tags) to be passed to the COMDACE
Material Control system. (PASCE System Users only).
Switch Layout

Switch
Position

Settings
Related Program Development Specs.

Version

Date

DEV. NO. 50A - ISOGEN TO 'COMPIPE' LINK.


8.13.0 RELEASE NOTES

First
Introduced

1.0

APR 83

Related Option Switches

Extended
Use

6.0

MAR 91

7.7

AUG 96

OS 60

ISSUE 2

OPT - 64

Details
Switches
by number
Switches
by name

- 92 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

PIPE SUPPORT IDENTIFICATION

64 Cont.

Description

This Option Switch controls the identification information that is output for
Pipe Supports on the isometric and parts list.
For identification purposes, either the Support Name (Tag) or Specification
Reference (Item Code) may be used, in the combinations listed below.
A further option allows certain support information to be passed to the
COMDACE Material Control system.
COMDACE is a registered trademark of John Brown Systems Ltd.
Switch Settings

SWITCH POSITION 3 - Support Names (Tags) enclosures


0
1
2
3
4
5
6
7
8

Square Ended Box Enclosure


Diamond Ended Box Enclosure
Round Ended Box Enclosure
Triangular Enclosure
Diamond Enclosure
Square Ended Box Enclosure
Circular Enclosure
Elliptical Enclosure
Hexagonal Enclosure

SWITCH POSITION 4 - Support Names (Tags) accumulation


0
1

Dont accumulate Supports with matching Names (Tags)


Accumulate Supports with matching Names (Tags).

Related Program Development Specs.


DEV. NO. 50 A - ISOGEN TO 'COMPIPE' LINK.
8.13.0 RELEASE NOTES
9.0.0 RELEASE NOTES

Extended
Use

Version

Date

6.0

MAR 91

7.7

AUG 96

8.13.0 SEP 06
9.0.0

ISSUE 2

MAY 08

OPT - 64

Switches
by number
Switches
by name

- 93 -

ALIAS

65. Bolting units

Options

ISOGEN
Switch Title

Option Switch No.

BOLTING UNITS

65

Description

Determines how Bolts are to be reported in terms of Diameter and Length


on the Material List and in the Material Control file, and also whether or
not they are to be included in the Material Control (MATC) file.
Actual data for Bolt Diameters and Length included in any Pipeline Data
File must be in the Units specified in this Option Switch.

Switch Settings

This option Switch is in two parts.

SWITCH POSITION 1 - Bolt Length Units and Material Control file option.
0
Default - whereby O.S. 41 Units setting is followed.
1
For Inch Lengths.
2
For mm. Lengths.
3
For No Bolts to be included in the MATC file.
(Normally, Bolts will be included).
SWITCH POSITION 2 - Bolt Diameter Units.
Blank
1
2

Default - whereby O.S. 41 Units setting is followed.


For Inch Diameters.
For mm. Diameters.
(Continued overpage)

Switch Layout

Switch
Position

Blank or
Value

Blank or
Value

Zero or
Value

Related Program Development Specs.


DEV. NO. 56 - USER DEFINED MATERIAL
LIST.
Related Option Switches.

Version
First
Introduced
Extended
Use

O.S. 41

Date

1.0

APR 83

7.0

OCT 93

Details

8.11.0 APR 03

OPT - 65

Switches
by number
Switches
by name

- 94 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

BOLTING UNITS

65 Cont.

Description

Bolts can now be excluded from the Material Control file.


(NOTE - Bolts can be suppressed from outputting to the Material Control
File by setting Position 1 = 3. Using the new Position 3 does not allow bolts
lengths to be controlled in the Material List)
Switch Settings

(Continued from previous page)

SWITCH POSITION 3 - Allows bolts to excluded from Material Control File


0

Output bolts to the Material Control File

Suppress the output of bolts to the Material Control File

Related Program Development Specs.


DEV. NO. 56 - USER DEFINED MATERIAL
LIST.
Related Option Switches.

Version
First
Introduced
Extended
Use

O.S. 41

Date

1.0

APR 83

7.0

OCT 93

8.11.0 APR 03

OPT - 65

Switches
by number
Switches
by name

- 95 -

ALIAS

66. Co-ordinates - Supplementary

Options

ISOGEN
Switch Title

Option Switch No.

CO-ORDINATES - SUPPLEMENTARY

66

Description

Controls the numerous output combinations that are available for the
plotting of N/S and E/W Co-ordinates and Elevations at Bend and Tee
intersection points, and at Isometric Split Points.
A further option is the output of Co-ordinates and Elevations along
Witness Lines rather than on the usual arrowed-out message lines.
Co-ordinates can be output at reference items and at pipe supports and
Location Points
Option also to output World co-ordinates information or Relative coordinates information from nearest Reference Plane.
Switch Settings

This option Switch is in eight parts.

SWITCH POSITION 1 -

0
1

Co-ordinates and Elevations output as


arrowed-out messages or on Witness Lines at
Bend and Tee intersection points.

Default for arrowed-out message type.


Co-ordinates and Elevations output along Witness Lines.

(Continued overpage)
Switch Layout

Switch
Position

Version

Date

Introduced

7.0

OCT 93

Extended
Use

8.3.0

JUL 00

All
Settings
Related Program Development Specs.
DEV. NO. 59 - DIMENSIONING & CO-ORDINATE UPGRADE.
First
DEV. NO. 83D - REFERENCE ITEMS CO-ORDINATES, THICKNESS & LAYER.

DEV. NO. 83E - PIPE SUPPORTS - CO-ORDINATES.

Related Option Switches.

Details
Switches
by number
Switches
by name

- 96 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

CO-ORDINATES - SUPPLEMENTARY
SWITCH POSITION 2 0
1
2
3

Co-ordinates and Elevations output at Bends


and Elbows.

Default, only output Elevations when changed.


No Elevations or Co-ordinates to be output.
Output Elevations and Co-ordinates that have changed.
Output a full set of Co-ordinates.

SWITCH POSITION 3 0
1
2
3

66 Cont.

Co-ordinate & Elevation output at Branch


Intersection Points

Default, only output Elevations when changed.


No Elevations or Co-ordinates to be output.
Output Elevations and Co-ordinates that have changed.
Output a full set of Co-ordinates.

SWITCH POSITION 4 - Co-ordinate output at Isometric Split Points.


0
1
2

Default, co-ordinates not output message points to end of


continuation components.
Full set of Co-ordinates output - message points to drawing split
point.
Co-ordinates not output message points to drawing split point.

SWITCH POSITION 5 - Co-ordinate output at Reference Items.


0
1

Co-ordinates not output at reference items.


Co-ordinates output at reference items.

SWITCH POSITION 6 0
1
2
3
4

Co-ordinate output at Pipe Supports

Co-ordinates not output at pipe supports.


Co-ordinates output at Fabrication pipe supports only.
Co-ordinates output at Erection pipe supports only.
Co-ordinates output at Offshore pipe supports only.
Co-ordinates output at all pipe supports.

Related Program Development Specs.

8.13.0 RELEASE NOTES

First
Introduced

Related Option Switches.

Extended
Use

Version

Date

8.13.0

SEP 06

OPT - 66

Details
Switches
by number
Switches
by name

- 97 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

CO-ORDINATES - SUPPLEMENTARY

SWITCH POSITION 7 0
1
2

Co-ordinate output at Location Points

No co-ordinate information output at Location Points.


World co-ordinate information output Points at Location
Points.
Relative co-ordinates information output from nearest
Reference Plane at Location Points.

SWITCH POSITION 8 0
1

66 Cont.

Co-ordinate output on isometric.

World co-ordinate information output.


Relative co-ordinates information output from nearest
Reference Plane.

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

Details

OPT - 66

Switches
by number
Switches
by name

- 98 -

ALIAS

67. Sloping pipeline - 3D skew depiction

Options

ISOGEN
Switch Title

Option Switch No.

SLOPING PIPELINE - 3D
SKEW DEPICTION

67

Description

Controls the method to be used for the depiction Sloping (Falling) sections
of a Pipeline that are skewed in the horizontal plane and display of angle
information on isometric drawing.
i)
Full 3D Skew Depiction. (Box or Triangle style).
ii)
2D Skew Depiction (Box or Triangle style) + a Fall Indicator.
iii)
Option to exclude, include or suppress angle information.
iv)
Either Deflected or Included angle.
Switch Settings

SWITCH POSITION 1 - Skew depiction - Box or Triangle + Fall indicator.


0
1

Default for full 3D Box / Triangle depiction.


2D Skew (Box or Triangle) + Fall Indicator.

SWITCH POSITION 2 - Angle information.


0
1
2
3

Output Angle information on the isometric drawing (except within


0.5 of 90 and 180).
Suppress Angle information on the isometric drawing.
Output Angle information on the isometric drawing (including
exactly 90 and 180).
Output Angle information unless when rounded they are within
0.1 of a degree of 90 or 180.

Switch Layout

Switch
Position

Setting
Related Program Development Specs.
DEV. NO. 11 - 3D SLOPING PIPELINE OUTPUT
AS 2D + FALL INDICATOR.
8.13.0 RELEASE NOTES
Related Option Switches.

1919 O.S.
2020 O.S.
9999
O.S.

Version
First
Introduced
Extended
Use

Date

1.0

APR 83

5.4

APR 87

8.12.0

JAN 05
SEP 06

8.13.0

Details

OPT - 67
Switches
by number
Switches
by name

- 99 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

SLOPING PIPELINE - 3D
SKEW DEPICTION

67 cont

Description

v) Accuracy of angle can be controlled

Switch Settings

SWITCH POSITION 3 Angle format.


0
1

Output Deflected angle.


Output Included angle.

SWITCH POSITION 4 Angle accuracy


0
1
2
3

Angles output to ISOGEN default accuracy of 0.5.


Angles output to the nearest degree.
Angles output to the nearest 10th degree (1 decimal place).
Angles output to the nearest 100th degree (2 decimal places).

Switch Layout

Switch
Position

Setting
Version

Related Program Development Specs.


9.2.0 RELEASE NOTES

Date

Details

First
Introduced
Extended
Use

Related Option Switches.

9.2

MAR 09

Switches
by number

O.S. 19 O.S. 20 O.S. 99

OPT - 67
- 100 -

Switches
by name

ALIAS

68. Sloping pipeline - Vertical branches

Options

ISOGEN
Switch Title

Option Switch No.

SLOPING PIPELINE VERTICAL BRANCHES

68

Description

Controls the drawing depiction method to be used when a vertical Branch


connection is to be made to a Sloping (Falling) Pipeline using a special Zero
Length Bend component.
This special Bend (which has no length) is used to carry the angle between
the Vertical Branch and the Sloping Pipeline.
Two drawing methods are available. One shows a small 2D skew box
section between the branch and the main pipe, while the other does not.
Where Olets are used in such cases, a text message indicates the orientation
direction if the Branch is not developed.
Switch Settings

Default to show the Short Tee branch leg section of pipe skewed.
Olets will have an orientation message instead of a skewed section.
Both will be dimensioned separately to the connecting pipe.

1
For No separate skew section, the vertical Branch is connected straight
into the main pipe. Olets will Not have an orientation message.
Both are included in a single inclusive dimension.
In both cases the angle between the vertical Branch and the Sloping (Falling)
pipeline will be indicated.

Switch Layout

Switch
Position

Either
Setting
Version

Related Program Development Specs.

DEV. NO. 2 - ZERO LENGTH BENDS.

First
Introduced

5.4

Date

APR 87

Extended
Use

OPT - 68

Switches
by number
Switches
by name

- 101 -

ALIAS

69. Terminal type identification

Options

ISOGEN
Switch Title

Option Switch No.

TERMINAL TYPE IDENTIFICATION

69

Description

Used to identify the type of graphics terminal.


The switch is a two part one where the basic terminal type is set in switch
positions 1, 2 and 3, with switch position 4 being used to denote single or dual
screen use.
Note. This Option Switch is only relevant when the graphics output is sent to
the terminal screen rather than to an output file.
Switch Settings

This Option Switch is in two parts.

SWITCH POSITIONS 1, 2 & 3 - Terminal Type.


0
The Default varies with the computer type.
e.g. a setting of 0 gives a Value of 3 on VAX, 7 on Apollo,
12 on HP Starbase, etc.
3
Tektronix 410X, 420X .
4
Westward 2000 and 2015 monochrome family.
5
Westward C2015 colour terminal.
6
IBM GDDM.
7
Apollo.
8
Tektronix 4111.
9
IBM PC emulating Tektronix 410X, 420X.
10
Westward 3220 / 2320.
(Continued overpage)
Switch Layout

Blank
or One

Switch
Position

All
Settings
Version

Related Program Development Specs.


First
Introduced

VERSION 6 RELEASE NOTES.

6.0

Date
MAR 91

Extended
Use

OPT - 69

Switches
by number
Switches
by name

- 102 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

TERMINAL TYPE IDENTIFICATION

69 Contd.

Description

Switch Settings

11
12
13
14
15
16

(Continued from previous page)

VAX VWS.
HP Starbase.
HP Starbase with X Windows.
DEC Windows.
Workstation / PC (Packet Driver).
Silicon Graphics.

SWITCH POSITION 4 - Dual Screen use.


Blank
Default for single screen operation.
1
For dual screen operation.

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 69
Switches
by number
Switches
by name

- 103 -

ALIAS

70. Skew indication - Branches

Options

ISOGEN
Switch Title

Option Switch No.

70

SKEW INDICATION - BRANCHES


Description

Optionally permits simple skewed Branch legs to have the normal Skew
Box / Triangle enclosure suppressed and replaced by a single pipe length
dimension and a text message giving the Branch Orientation.
When used to suppress the normal box enclosure, the value set represents
the maximum number of fittings permitted in the Branch. Branches found
to contain more fittings than this will be drawn with the normal Skew Box /
Triangle enclosure.
Switch Settings

SWITCH POSITIONS 1 & 2 Suppress skew box on branches


0
Default for all Branches to be drawn with normal Skew Box /
Triangle depiction.
Value

Suppress Skew Box / Triangle depiction on Branch Legs whose


number of components is less than or equal to the Value set, and
output an Orientation Message.

Note. This facility is only available on straight through Branches. Any


change in direction along the Branch will automatically cause the program
to default to normal Skew Box / Triangle output.

( Continued overpage )
Switch Layout

Blank Zero
or 1 or 1

Switch
Position

Zero or
Value

Version
Related Program Development Specs.
DEV. NO 35 - SUPPRESSION OF SKEW BOXES
/ TRIANGLES ON BRANCH LEGS. First
5.4.1
Introduced
Extended
Use

Date

FEB 88

8.11.0 APR 03
9.2.0 MAR 09

OPT - 70

Details
Switches
by number
Switches
by name

- 104 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

70 Cont.

SKEW INDICATION - BRANCHES


Description

Skew orientation directions can now be output showing rotation relative


to previous position or rotation from primary direction
An orientation message can also be output on undeveloped olets
in a primary direction

Switch Settings

( Continued from previous page )

SWITCH POSITION 3- Skew rotation depiction


0

Orientation direction message relative to previous position

Orientation direction message relative to primary direction

SWITCH POSITION 4 - Olet direction messages for Primary


Directions
0

Undeveloped Olet in a primary direction does not


create an orientation message.

Undeveloped Olet in a primary direction creates an


orientation message

Switch Layout

Version
Related Program Development Specs.
DEV. NO 35 - SUPPRESSION OF SKEW BOXES
First
/ TRIANGLES ON BRANCH LEGS.
5.4.1
Introduced

Date

FEB 88

Extended
Use

Details

OPT - 70
Switches
by number
Switches
by name

- 105 -

ALIAS

71. Plotfile format

Options

ISOGEN
Switch Title

Option Switch No.

71

PLOTFILE FORMAT
Description

This Option Switch controls :i) Plotfile Output Format. The Smart Format of graphics relates to a
Plotfile that has (a) vectors associated with a pipeline component grouped
together to form a single object in the drawing file (b) has some non
graphical attributes associated with the symbol (Tags/Attributes).
ii) File format of any nominated Backing Frame and Detail Sketch files.
iii) The generation of an I01 type filename extension.
Switch Settings

This Option Switch is in six parts.

SWITCH POSITIONS 1, 2 & 3 - Plotfile Output Format.


0
3
4
8
11
16

Switch Layout

Default for ISOGEN plotfile format (ISO).


Postscript (PSC), Backing Frame unavailable.
AutoCAD V12 DXF format, Backing Frame optional.
MicroStation DGN V7 and below, Backing Frame
mandatory.
Alias internal Smart format (POD), Backing Frame optional.
AutoCAD DXF Smart format, Backing Frame mandatory.
The AutoCAD DXF Plotfile version will be the same as that of
the DXF Backing Frame.
(Continued overpage).
7

All
Settings

All
Settings

Related Program Development Specs.


VERSION 6.0 RELEASE NOTES
DEV. NO. 62 - DETAIL SKETCHES FACILITY
V8.10.0 RELEASE NOTES
Related Option Switches.
O.S. 92 O.S. 138

ISSUE 3

Switch
Position

All
Settings
Version

Date

First
Introduced

6.0

MAR 91

Extended
Use

7.0
7.14.4

OCT 94
JUL 98

OPT - 71

Details
Switches
by number
Switches
by name

- 106 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

PLOTFILE FORMAT

(Continued from previous page).

Switch Settings

17

18
19
20
21

71 Cont

AutoCAD DWG Smart format, Backing Frame mandatory.


The AutoCAD DWG Plotfile version will be the same as that
of the DWG Backing Frame.
MicroStation DGN V7 and below Smart format, Backing
Frame mandatory.
SmartSketch IGR Smart format, Backing Frame
mandatory.
SmartPlant SHAPE2D SHA Smart format, Backing Frame
mandatory.
MicroStation DGN V8 and above Smart format, Backing
Frame mandatory.

SWITCH POSITION 4, 5 & 6 - Backing Frame and Detail Sketch file


format.
Note: Format must match that specified for the Plotfile Output as set in
Position 1, 2 & 3 and must be of the same CAD system version as the
requested Plotfile Output Format.
4
8
11
16
17

18
19
20
21

AutoCAD V12 DXF format.


MicroStation DGN V7 and below format.
Alias internal Smart format (POD)
AutoCAD DXF format. The generated plotfile will be the
same AutoCAD DXF version as this Backing Frame.
AutoCAD DWG format, Backing Frame mandatory. The
generated plotfile will be the same AutoCAD DWG version
as the Backing Frame.
MicroStation DGN V7 and below format.
SmartSketch IGR Smart format.
SmartPlant SHAPE2D SHA format.
Smart MicroStation DGN V8 and above.

Related Option Switches.

Extended
Use

O.S. 92 O.S. 138

ISSUE 3

8.10.0 MAY 02

OPT - 71
Switches
by number
Switches
by name

- 107 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

PLOTFILE FORMAT

71 Cont
(Continued from previous page).

Switch Settings

SWITCH POSITION 7 - Generation of I01 type file name extension.


0
1
2

For normal filenames / extensions.


To have I01 type filename extensions on all plotfiles
generated that do not use a user defined plotfile prefix.
To have the plotfile output format extension appended to the
I01 type filename extension on all plotfiles generated that do
not use a user defined plotfile prefix.

Details
Related Option Switches.

Extended
Use

O.S. 92 O.S. 138

8.10.0 MAY 02

OPT - 71

ISSUE 3

- 108 -

Switches
by number
Switches
by name

ALIAS

72. Leading Zeros

Options

ISOGEN
Switch Title

Option Switch No.

LEADING ZEROS

72

Description

Used to control the number of characters to be output in either a


Material Part Identifier, Cut Piece Identifier or Spool Number.
This option does not operate when alphabetic Spool Identifiers are chosen
or user defined Spool Identifiers are being used. If a Spool Prefix is present
leading zeros are output immediately before the individual Spool value.
If numeric Material Part Identifier, Cut Piece Identifier or Spool dentifier
are to be output, leading zero(s) will be inserted where appropriate.

Switch Settings

SWITCH POSITION 1 - Characters output - Spool Identifiers.


0
X

No leading characters output before Spool Identifier.


Number of characters output in Spool Identifier.

SWITCH POSITION 2 - Characters output Cut Piece Identifiers.


0
X

No leading characters output before Cut Piece Identifier.


Number of characters output in Cut Piece Identifier.

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

Details

OPT - 72

Switches
by number
Switches
by name

- 109 -

ALIAS

73. Material part number enclosure style

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL PART NUMBER


ENCLOSURE STYLE

73

Description

The Material Part Number enclosure Shapes controlled by O.S. 76 can be


further varied by the use of one of three alternative Blank Enclosures Styles
controlled by this Option Switch.
A Style 1 enclosure is a Blank Box of variable size and shape output below
the Standard Material Part number.
A Style 2 enclosure is an extended Standard Material Part Number box with
a Blank section.
A Style 3 enclosure is for the output of Weld Part Numbers for Welds that
have been included on the Material List, and like Style 2 will have a Blank
section. This is a special function type enclosure that is only available when
O.S. 23 - Position 2 is set to a value of 1.
This Option Switch controls the Style, Shape and Size of these Blank boxes.
All three styles provide a space for the manual addition of supplementary
information to the isometric.

Switch Settings

This Option Switch is in four parts.

SWITCH POSITIONS 1 & 2 - Style 1 Enclosure Box size.


0
Default for the standard part number box enclosure with no
additional Style 1 Enclosure Box.
Value
Where Value equals the number of blank characters that
dynamically determines the size of the additional Style 1
Enclosure Box.
(Continued overpage)

Switch Layout

Switch
Position

All
Settings
Related Program Development Specs.

DEV. NO. 56 - USER DEFINED MATERIAL First


LIST.
Introduced
Related Option Switches.

Version

Date

7.0

OCT 94

Extended
Use

O.S.
7676

ISSUE 2

Details

OPT - 73

Switches
by number
Switches
by name

- 110 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL PART NUMBER


ENCLOSURE STYLE

73 Contd.

Description

Switch Settings

(Continued from previous page)

SWITCH POSITIONS 3 & 4 - Style 2 Enclosure Box setting.


0
Default for no extended Style 2 Enclosure Box.
Value
Where Value equals the number of blank characters that
dynamically determines the size of the extended Style 2
Enclosure Box.
Note. The Style 2 Enclosure Box shape is controlled by the setting of O.S. 76.
SWITCH POSITION 5 - Style 1 Enclosure Box shape.
0
Enclosure Box with Square ends.
1
Enclosure Box with Diamond ends.
2
Enclosure Box with Round ends.
SWITCH POSITIONS 6 & 7 - Style 3 Enclosure Box setting (For Welds on
the Material List).
Blank
Default for no extended Style 3 Enclosure Box.
Value
Where Value equals the number of blank characters that
dynamically determines the size of the extended Style 3
Enclosure Box.

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

76
ISSUE 2

Details

OPT - 73

Switches
by number
Switches
by name

- 111 -

ALIAS

74. Material list accumulation control

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL LIST ACCUMULATION


CONTROL

74

Description

There are extensive options that determine how components are included
on or excluded from the Material List.
Materials may be processed by category - Fabrication, Erection or
Offshore, and, furthermore, Gasket, Bolt and Weld Groups may be
controlled separately.
Non-accumulation means that each occurrence of an item will result in an
individual entry being made on the Material List with a quantity of 1 off,
or, in the case of Pipe, each individual length will be listed separately.
Finally, there is an option to have nominated Material categories
suppressed completely.
Switch Settings

This Option Switch is in six parts.

SWITCH POSITION 1 - Fabrication Materials.


0
1
2
3
4

Default to have all Fabrication items accumulated normally.


For non-accumulation of all Fabrication items (excluding
Pipe).
For all Fabrication items to be suppressed.
For non-accumulation of Fabrication items (including Pipe).
For non-accumulation of Pipe only.

Switch Layout

Switch
Position

All
Settings
Version

Date

First
Introduced

7.0

OCT 94

Extended
Use

7.4
8.11

DEC 95
FEB 04

Related Program Development Specs.

DEV. NO. 56 - USER DEFINED MATERIAL


LIST

ISSUE 2

OPT - 74

Details
Switches
by number
Switches
by name

- 112 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL LIST ACCUMULATION


CONTROL

74 Contd.

SWITCH POSITION 2 - Erection Materials.


0
1
2
3
4

Default to have all Erection items accumulated normally.


For non-accumulation of all Erection items (excluding
Pipe).
For all Erection items to be suppressed.
For non-accumulation of Erection items (including Pipe).
For non-accumulation of Pipe only.

SWITCH POSITION 3 - Offshore Materials.


0
1
2
3
4

Default to have all Offshore items accumulated normally.


For non-accumulation of all Offshore items (excluding
Pipe).
For all Offshore items to be suppressed.
For non-accumulation of Offshore items (including Pipe).
For non-accumulation of Pipe only.

SWITCH POSITION 4 - Gaskets.


0
Default to have Gaskets accumulated normally.
1
For non-accumulation of Gaskets.
2
For all Gaskets to be suppressed.
SWITCH POSITION 5 - Bolts.
0
Default to have Bolts accumulated normally.
1
For non-accumulation of Bolts.
2
For all Bolts to be suppressed.
SWITCH POSITION 6 - Welds.
0
Default to have Welds accumulated normally.
1
For non-accumulation of Welds.
2
For all Welds to be suppressed.
Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

Details

OPT - 74

Switches
by number
Switches
by name

- 113 -

ALIAS

75. Weld number - Enclosure and prefix

Options

ISOGEN
Switch Title

Option Switch No.

WELD NUMBER - ENCLOSURE


WELD NUMBER - PREFIX

75

Description

Weld Numbers can optionally have a Weld Prefix character(s), and a variety
of enclosure types.
Both the Weld Number enclosure type and the Weld Prefix may be
separately controlled for Shop, Site / Field and Offshore welds.
Note. When the Weld Number enclosure style is not the original circular
type then the Weld Number character size is controlled by O.S. 4 and
not O.S. 53.
This Option Switch is in nine parts.

Switch Settings

SWITCH POSITION 1 - Weld Number Enclosure style for Shop Welds.


0
1
2
3
4
5
6
7
8
9

Default for Weld Numbers in a fixed sized circle.


Diamond ended box.
Round ended box.
Small triangular shaped enclosure.
Small diamond shaped enclosure.
Square ended box.
Dynamically sized circle.
No weld number enclosure.
No shop weld numbers to be output on the plotted isometric.
Elliptical weld enclosure.
(Continued overpage)

Switch Layout

Switch
Position

Blank
or one

Zero
or one

Zero
Zero
Zero Zero Zero
or value or one or value or one or value

Related Program Development Specs.

DEV. NO. 57 - WELDING FACILITIES


DEV. NO. 89H - MESSAGE ENCLOSURES

First
Introduced

Related Option Switches.

Extended
Use

O.S. 53 O.S. 54 O.S. 77

ISSUE 2

Version

Date

7.0

OCT 94

7.6

MAY 96

Details

8.10.0 MAY 02

OPT - 75

Switches
by number
Switches
by name

- 114 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

WELD NUMBER - ENCLOSURE


WELD NUMBER - PREFIX

75 Contd.
(Continued from previous page)

Switch Settings

SWITCH POSITION 2 - Weld Prefix on Shop Welds.


0
1

Default for No Weld Prefix to be added.


Weld Prefix added to Weld Number.

SWITCH POSITION 3 - Weld Number Enclosure style for Site / Field


Welds.
0
1
2
3
4
5
6
7
8
9

Default for Weld Numbers in a fixed sized circle.


Diamond ended box.
Round ended box.
Small triangular shaped enclosure.
Small diamond shaped enclosure.
Square ended box.
Dynamically sized circle.
No weld number enclosure.
No Site/Field weld numbers to be output on the plotted
isometric.
Elliptical weld enclosure.

SWITCH POSITION 4 - Weld Prefix on Site / Field Welds.


0
1

Default for No Weld Prefix to be added.


For Weld Prefix added to Weld Number.

SWITCH POSITION 5 - Weld Number Enclosure style for Offshore


Welds.
0
1
2
3
4
5
6
7
8
9

Default for Weld Numbers in a fixed sized circle.


Diamond ended box.
Round ended box.
Small triangular shaped enclosure.
Small diamond shaped enclosure.
Square ended box.
Dynamically sized circle.
No weld number enclosure.
No Offshore weld numbers to be output on the plotted
isometric.
Elliptical weld enclosure.

ISSUE 2

OPT - 75

Details
Switches
by number
Switches
by name

- 115 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

WELD NUMBER - ENCLOSURE


WELD NUMBER - PREFIX

75 Contd.
(Continued from previous page)

Switch Settings

SWITCH POSITION 6 - Weld Prefix on Offshore Welds.


0
1

Default for No Weld Prefix to be added.


For Weld Prefix added to Weld Number.

SWITCH POSITION 7 - Double line Weld Number Enclosure style for


Shop Welds.
0
1

Single line circle enclosure.


Double line Weld Number Enclosure (use with circular
enclosure to get double circles).

SWITCH POSITION 8 - Double line Weld Number Enclosure style for


Field / Site Welds.

0
1

Single line circle enclosure.


Double line Weld Number Enclosure (use with circular
enclosure to get double circles).

SWITCH POSITION 9 - Double line Weld Number Enclosure style for


Offshore Welds.

0/Blank
1

Single line circle enclosure.


Double line Weld Number Enclosure (use with circular
enclosure to get double circles).

ISSUE 2

OPT - 75

Switches
by number
Switches
by name

- 116 -

ALIAS

76. Material part number enclosure shape

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL PART NUMBER


ENCLOSURE SHAPE

76

Description

Controls the Shape of the Box Enclosure used to surround the standard
type of Material List Part Numbers on the isometric.
(For details of an alternative Material List Part Number Box Enclosure
Style - see O.S. 73).
Switch Settings

SWITCH POSITION 1 - Material Part Number Enclosures


0
1
2
6
7
8
9

Default for standard enclosure box shape with rectangular


ends.
Enclosure box shape with Diamond ends.
Enclosure box shape with Round ends.
Circular enclosure.
No enclosure box - only Part Number text plotted.
No Part Numbers nor enclosure box plotted.
(Note. In this case, any setting in O.S. 73 is ignored).
Elliptical enclosure.

Note. When set, values 1,2 and 7 above will also be applied to the shape of
the alternative Style 2 Material List Part Number Enclosure Box as
controlled by O.S. 73.

Switch Layout

Switch
Position

0
Zero
or Value
Related Program Development Specs.

DEV. NO. 89H - MESSAGE ENCLOSURES ELLIPSES AND DOUBLE CIRCLES

First
Introduced

Related Option Switches.

Extended
Use

O.S. 73

ISSUE 2

Version

Date

7.3

SEP 95

8.10.0 MAY 02

OPT - 76

Details
Switches
by number
Switches
by name

- 117 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL PART NUMBER


ENCLOSURE SHAPE

76 cont

SWITCH POSITION 2 - Single/Double Line Circular Material Part


Number Enclosures
0
1

Single line Part Number enclosure.


Double line Part Number enclosure (use with circular
enclosure to get double circles).

SWITCH POSITION 3 - Material Part Number Circular or Elliptical


Enclosure Size.
0
1 to 8
9

Part Number circular or elliptical enclosures fixed to 2


characters.
Part Number circular or elliptical enclosures fixed to value
set.
Part Number circular or elliptical enclosures variable sizes.

SWITCH POSITION 4 - Material Part Numbering - leading zeros.


0
X

No leading characters output before Material Part Number.


Number of characters output in Material Part Number.

Details

ISSUE 2

OPT - 76

Switches
by number
Switches
by name

- 118 -

ALIAS

77. Weld number allocation at slip-on flanges and reinforcement pads

Options

ISOGEN
Switch Title

Option Switch No.

WELD NUMBER ALLOCATION AT SLIPON FLANGES & REINFORCEMENT PADS

77

Description

Controls the quantity of Weld Numbers that are generated by the program
at Slip-On Flange and Reinforcement Pad positions.
On Reinforcement Pads, also controlled is the optional generation of an
Item Code / Material Description on the Material List and the plotting of
the Pad shape.
Note. Reinforcement Pads may optionally exist on Set-On Tees / Crosses
and on Trunnion type Pipe Supports.
Switch Settings

This Option Switch is in four parts.


SWITCH POSITION 1 - Quantity of Weld Numbers generated at Slip-On
Flanges.
0
Default for 2 Weld Numbers.
1
For 1 Weld Number.
2
For 2 Weld Numbers.

SWITCH POSITION 2 - Quantity of extra Weld Numbers generated at


Reinforcement Pads.
0 or blank Default for 0 extra Weld Numbers.
1
For 1 extra Weld Number.
2
For 2 extra Weld Numbers.
Note. These are extra Weld Numbers because they are created in addition to
the normal single and double branch connection Weld Numbers that are
generated at Set-On Tee and Cross positions.
(Continued over page)
Switch Layout

Switch
Position

All
Blank
Zero Value Zero
Settings
or value See over or one
or one
Related Program Development Specs.
DEV. NO. 65G - WELD NUMBERS AT
REINFORCEMENT PADS.
Related Option Switches.
O.S. 53 O.S. 54 O.S.75

ISSUE 3

Version

Date

First
Introduced

7.4

DEC 95

Extended
Use

7.13.0

FEB 98

8.10.0

MAY 02

OPT - 77

Details
Switches
by number
Switches
by name

- 119 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

WELD NUMBER ALLOCATION AT SLIPON FLANGES & REINFORCEMENT


Switch Settings

77 Contd.

(Continued from previous page).

SWITCH POSITION 3 - For Reinforcement Pads, controls the automatic


generation of an Item Code and Material Description on the Material List
and a plotted shape for the Pad on the isometric.
0
1

Default for No generation of Item Code / Material


Description and No plotted Pad shape.
For the automatic generation of an Item Code / Material
Description and a plotted Pad shape.

SWITCH POSITION 4 - For allocation of Weld Numbers on Fabricated


Y types.
0 or Blank
1
2

Default for ONE Weld Number.


ONE Weld Number.
TWO Weld Numbers.

SWITCH POSITION 5 - For allocation of Weld Numbers on Tack Welds.


0
1

Weld Numbers allocated to Tack Welds.


Weld Numbers not allocated to Tack Welds.

SWITCH POSITION 6 - Allocated for future use.

SWITCH POSITION 7 - For allocation of Weld Numbers to Victaulic


Welded / Forged Ring Type Clamps (CLVR).
0
1 to 9

2 Weld Numbers allocated to Victaulic Clamp.


Specified Weld Numbers allocated to Victaulic Clamp.

Details

ISSUE 3

OPT - 77

Switches
by number
Switches
by name

- 120 -

ALIAS

78. Support Weld Number Enclosures

Options

ISOGEN
Switch Title

Option Switch No.

SUPPORT WELD NUMBER PREFIX


AND ENCLOSURES

78

Description

Support Weld Numbers can optionally have a Support Weld Prefix and
be output in a variety of different enclosure styles.
Both the Support Weld enclosure style and prefix can be separately
controlled for Shop, Site and Offshore categories.
This Option Switch is in nine parts.

Switch Settings

SWITCH POSITION 1 -

0
1
2
3
4
5
6
7
8
9

Weld Number enclosure style for Fabrication


Support Welds

Fixed size circle.


Diamond ended box.
Round ended box.
Small triangular shape.
Small diamond shape.
Square ended box.
Dynamically sized circle.
No enclosure.
Weld Number suppressed.
Elliptical Weld Number enclosure.

Switch Layout

Switch
Position

Blank
or one

Zero
or one

Zero Zero
Zero
Zero
or value or one or value or one

Zero
or value

Related Program Development Specs.


DEV. NO. 57 - WELDING FACILITIES UPGRADE First
DEV. NO. 74D - SUPPORT WELD PREFIX AND
Introduced
NUMBERING SEQUENCES

Version

Date

Related Option Switches.

7.16.0

MAY 99

8.10.0

MAY 02

Extended
Use

O.S. 53

OPT - 78

Switches
by number
Switches
by name

- 121 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

SUPPORT WELD NUMBER PREFIX


AND ENCLOSURES

78 cont

SWITCH POSITION 2 - Weld Prefix on Fabrication Support Welds


0
1

No Weld Prefix to be added.


Support Weld Prefix to be added to Weld Number.

SWITCH POSITION 3 - Weld Number Enclosure Style for Erection


Support Welds.
0
1
2
3
4
5
6
7
8
9

Fixed size circle.


Diamond ended box.
Round ended box.
Small triangular shape.
Small diamond shape.
Square ended box.
Dynamically sized circle.
No enclosure.
Weld Number suppressed.
Elliptical Weld Number enclosure.

SWITCH POSITION 4 - Weld Prefix on Erection Support Welds.


0
1

No Weld Prefix to be added.


Support Weld Prefix to be added to Weld Number.

SWITCH POSITION 5 - Weld Number Enclosure Style for Offshore


Support Welds.
0
1
2
3
4
5
6
7
8
9

Fixed size circle.


Diamond ended box.
Round ended box.
Small triangular shape.
Small diamond shape.
Square ended box.
Dynamically sized circle.
No enclosure.
Weld Number suppressed.
Elliptical Weld Number enclosure.

OPT - 78

Switches
by number
Switches
by name

- 122 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

SUPPORT WELD NUMBER PREFIX


AND ENCLOSURES

78 cont

SWITCH POSITION 6 - Weld Prefix on Offshore Support Welds


0
1

No Weld Prefix to be added.


Support Weld Prefix to be added to Weld Number.

SWITCH POSITION 7 - Double Line Weld Number Enclosure Style for


Fabrication Support Welds
0
1

Single line circle Weld Number enclosure.


Double line Weld Number enclosure (use with circular
enclosure to get double circles).

SWITCH POSITION 8 - Double Line Weld Number Enclosure Style for


Erection Support Welds
0
1

Single line circle Weld Number enclosure.


Double line Weld Number enclosure (use with circular
enclosure to get double circles).

SWITCH POSITION 9 - Double Line Weld Number Enclosure Style for


Offshore Support Welds
Blank
1

Single line circle Weld Number enclosure.


Double line Weld Number enclosure (use with circular
enclosure to get double circles).

Details

OPT - 78

Switches
by number
Switches
by name

- 123 -

ALIAS

79. Site Assembly Identification

Options

ISOGEN
Switch Title

Option Switch No.

SITE ASSEMBLY IDENTIFICATION

79

Description

Allows identification of flanged assemblies on the isometric drawing


using different enclosure types. It permits a table of assembly
information to be positioned on the drawing frame. This can be either
on a per drawing or per pipeline basis.

Switch Settings

This Option Switch is in nine parts.

SWITCH POSITION 1 -

Output of flange assembly identification.

0
1
2

Flange assembly identification not output.


Numeric flange assembly identification.
Alpha flange assembly identification.

SWITCH POSITION 2 -

Flange assembly identification per drawing or


per pipeline.

0
1

Flange assembly identification per drawing.


Flange assembly identification per pipeline.
(Continued overpage)

Switch Layout

Switch
Position

0
(5-8 unused)
All settings

All settings

Version
Related Program Development Specs.
DEV. NO. 85 - SITE ASSEMBLY IDENTIFICATION First
8.4.0
DEV. NO. 89H - MESSAGE ENCLOSURES
Introduced
Related Option Switches.

Extended
Use

Date

JUL 00

8.10.0 MAY 02

OPT - 79

Details
Switches
by number
Switches
by name

- 124 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

SITE ASSEMBLY IDENTIFICATION

79 cont

SWITCH POSITION 3 - Enclosure type.


0
1
2
3
4
5
6
8
9

No enclosure.
Diamond ended box enclosure.
Round ended box enclosure.
Triangular enclosure.
Diamond enclosure.
Square ended box enclosure.
Circular enclosure.
Double circle assembly enclosure.
Elliptical assembly enclosure.

SWITCH POSITION 4 - Output of Flange Assembly Table.


0
1

Flange assembly table not required on drawing.


Flange assembly table required on drawing.

SWITCH POSITIONS 5-8 - Unused.


SWITCH POSITION 9 - Circular or Elliptical Weld Number Enclosures.
0
1 to 8
9

Weld Number circular or elliptical enclosures fixed to 2


characters.
Weld Number circular or elliptical enclosures fixed to
value set.
Weld Number circular or elliptical enclosures variable sizes.

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

Details

OPT - 79

Switches
by number
Switches
by name

- 125 -

ALIAS

80. Dimensions - To valve centres

Options

ISOGEN
Switch Title

Option Switch No.

DIMENSIONS - TO VALVE CENTRES

80

Description

Valves and straight through Instruments which have a Spindle may


optionally be Dimensioned to their Centre Points rather than to their ends
using either String or Composite Dimensions.
Controls here permit the function to operate selectively, based upon the
type of end connection, e.g. Socket Weld, Screwed, Compression, etc.
This Option Switch can operate in conjunction with Option Switch 81 which adds bore selectivity.
This Option Switch is in seven parts.
SWITCH POSITION 1 - For Butt Weld end Valves and Instruments.
0
Default for components with Butt Weld ends to be Dimensioned
across their length.
1
For components with Butt Weld ends to have Centreline Dimensions.
SWITCH POSITION 2 - For Compression end Valves and Instruments.
0
Default for components with Compression ends to be Dimensioned
across their length.
1
For components with Compression ends to have Centreline
Dimensions.
SWITCH POSITION 3 - For Screwed end Valves and Instruments.
0
Default for components with Screwed ends to be Dimensioned across
their length.
1
For components with Screwed ends to have Centreline Dimensions.

Switch Settings

(Continued overpage)

Switch Layout

Switch
Position

All
Settings
Version

Related Program Development Specs.

DEV. NO. 59 - DIMENSIONING UPGRADE. First

Introduced

Related Option Switches.

7.0

Date

OCT 94

Extended
Use

O.S.
8181

Details

OPT - 80

Switches
by number
Switches
by name

- 126 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

DIMENSIONS - TO VALVE CENTRES

80 Contd.

Description

Switch Settings

(Continued from previous page).


SWITCH POSITION 4 - For Socket Weld end Valves and Instruments.
0
Default for components with Socket Weld ends to be
Dimensioned across their length.
1
For components with Socket Weld ends to have Centreline
Dimensions.
SWITCH POSITION 5 - For Flanged end Valves and Instruments.
0
Default for components with Flanged ends to be Dimensioned
across their length.
1
For components with Flanged ends to have Centreline
Dimensions.
SWITCH POSITION 6 - For Plain end Valves and Instruments.
0
Default for components with Plain ends to be Dimensioned
across their length.
1
For components with Plain ends to have Centreline
Dimensions.
SWITCH POSITION 7 - For Hygienic end Valves and Instruments.
Blank
Default for components with Hygienic ends to be
Dimensioned across their length.
1
For components with Hygienic ends to have Centreline
Dimensions.

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

81

Details

OPT - 80

Switches
by number
Switches
by name

- 127 -

ALIAS

81. Dimensions - Branches

Options

ISOGEN
Switch Title

Option Switch No.

DIMENSIONS - BRANCHES

81

Description

This Option Switch controls two separate functions :i) Dimensions to the Centre Point of Valves and straight through
Instruments selectively based upon bore. This operates in conjunction
with O. S. 80 - which operates on End type.
ii) Un-dimensioned Branch legs, selectively based upon Bore and / or on
the number of components in the Branch
This Option Switch is in three parts.
SWITCH POSITIONS 1, 2 & 3 - Dimensions to the Centre Point of Valves
and straight through Instruments.
0
Default for Valves / Instruments that have their End Type set in
O.S. 80 to be Dimensioned to their Centre Point.
Value
For Valves / Instruments that have their End Type set in O.S. 80
and have a Bore equal to or less than the Value set to be
dimensioned to their Centre Point. Value is in 1/16" or mm's
depending upon the Bore units.
SWITCH POSITIONS 4, 5 & 6 -Branches within specified Bore range to be
Un-dimensioned. (Works in conjunction
with Positions 7 & 8, if set - see next page).
0
Default for all Branches to be Dimensioned.
Value
For Branches having a Bore equal to or less than Value to have
Dimnsions suppressed. Value is in 1/16" or mm's depending
upon the Bore units.
(Continued overpage)

Switch Settings

Switch Layout

Switch
Position

Blank or
Value

Zero or Value

Zero or Value
Version

Related Program Development Specs.

DEV. NO. 59 - DIMENSIONING UPGRADE. First

Introduced

Related Option Switches.

7.0

Date

OCT 94

Extended
Use

O.S.
8080

OPT - 81

Switches
by number
Switches
by name

- 128 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

DIMENSIONS - BRANCHES

81 Contd.

Switch Settings

SWITCH POSITIONS 7 & 8 - Branches with a specified number of


components to be Un-dimensioned. (Works in conjunction with Positions
4,5 and 6, if set, see previous page).
Blank
Value

Default for all Branches to be Dimensioned.


For Branches having a number of Components equal to or
less than Value, to have Dimensions suppressed. Gasket and
Bolt entries are counted as Components.

SWITCH POSITION 9 - Tee & Tapped Branch dimensioning method


0
1

Tee and Tapped Branches dimensioned as at present.


Tap Branch dimension to have ATex EOP output with
associated dimension. (This is where the User is defining the
start of the Tapped Branch that is not at the intersection
point).
Tee and Tap Branch dimension to have ATex EOP output
with associated dimension. (All set on type branches and tap
points involving pipe have been designed where the branch
start points are not at the intersection points).

Notes
i) Any Branch containing Pipe (100 record), Fixed Length Pipe (101
record) or Pipe Block (103 record) will not have Branch Dimension
Suppression applied to it.
ii) Branch Dimension Suppression using this Option Switch does not apply
to Tapped Branches.
iii) Switch Positions 4,5 & 6 and 7 & 8 will work either independently of
each other or together depending upon the Users requirement.
iv) OS 9, Pos 2 - this does not include Olet type branches.
Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

80

OPT - 81
Switches
by number
Switches
by name

- 129 -

ALIAS

82. C of G / Weight output

Options

ISOGEN
Switch Title

Option Switch No.

C of G / WEIGHT OUTPUT

82

Description

This Option Switch allows the User to control the generation and output of
additional Weight information not covered by Option Switch 41, plus a full
range of C of G (Centre of Gravity) positions.
Control over outputs for either single isometrics or the complete Pipeline is
also provided.

Switch Settings

This Option Switch is in five parts.

SWITCH POSITION 1 - Outputs suppressed, by single isometric or by


complete Pipeline.
0
None of the outputs controlled by this Option Switch are required.
1
All nominated outputs are required per Drawing or per Spool
Drawing.
2
All nominated outputs are required per complete Pipeline.
SWITCH POSITION 2 - Output of Wet (Full) Weight.
0 or blank Wet Weight Not required.
1
Wet Weight Is required.
SWITCH POSITION 3 - Output of Insulation Weight.
0 or blank Insulation Weight Not required.
1
Insulation Weight Is required.
(Continued overpage)

Switch Layout

Switch
Position

Blank
or Value

Zero, Blank
or Value

Zero
or Value
Version

Related Program Development Specs.


DEV. NO. 64 - WEIGHT / C of G FACILITY.
Related Option Switches.

First
Introduced

7.2

Date

FEB 95

Extended
Use

O.S.
4141

OPT - 82
Switches
by number
Switches
by name

- 130 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

C of G / WEIGHT OUTPUT

82Contd.

Description

Switch Settings

(Continued from previous page)

SWITCH POSITION 4 - Output of Dry (Empty) C of G positions.


0 or blank Dry (Empty) C of G position Not required.
1
Dry (Empty) C of G position Is required.
2
Dry (Empty) + Insulation C of G Is required.
3
Dry (Empty) C Of G and Dry (empty) + Insulation C of G Are
both required.
SWITCH POSITION 5 - Output of Wet (Full) C of G positions.
Blank
Wet (Full) C of G position Not required.
1
Wet (Full) C of G position Is required.
2
Wet (Full) + Insulation C of G Is required.
3
Wet (Full) C Of G and Wet (Full) + Insulation C of G Are
both required.

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Related Option Switches.

Extended
Use

41

OPT - 82
Switches
by number
Switches
by name

- 131 -

ALIAS

83. Site Welds Associated with Spools

Options

ISOGEN
Switch Title

Option Switch No.

SITE WELDS ASSOCIATED WITH SPOOLS

83

Description
By default, ISOGEN assigns Site Welds to a spool if they are adjoining. This option
controls assignment of Site Welds to spools.

Switch Settings

SWITCH POSITION 1 - Assignment of Site Welds to spools


0
1

Site Weld assigned to adjoining spools.


Site Welds not assigned to spools.

Switch Layout

Switch
Position

Zero or one
Version

Related Program Development Specs.

First
8.13.1
Introduced

ISOGEN 8.13.1 RELEASE NOTES

Date

MAY 07

Extended
Use

OPT - 83

Switches
by number
Switches
by name

- 132 -

ALIAS

84. Curved Pipe

Options

ISOGEN
Switch Title

Option Switch No.

CURVED PIPE

84

Description

To allow for additional control when outputting Curved Pipe on the isometric
drawing, the user having control of
Dimensioning of Curved Pipe
Output of Curved Pipe angle
Output of Curved Pipe radius

Switch Settings

SWITCH POSITION 1 - Dimensioning of curved pipe


0
1
2

Output Curved Pipe dimensions as a message.


Output Curved Pipe dimensions as a standard dimension.
Suppress Curved Pipe dimensions.

SWITCH POSITION 2 - Curved pipe angle


0
1
2

Output Curved Pipe angle as a message.


Output Curved Pipe angle as part of dimension.
Suppress Curved Pipe angle.

SWITCH POSITION 3 - Curved pipe radius


0
1

Output Curved Pipe radius as a message.


Suppress Curved Pipe angle.

Switch Layout

Switch
Position

0
Zero or value
Version

Related Program Development Specs.

First
9.0
Introduced

9.0.0 RELEASE NOTES

Date

MAY 08

Extended
Use

OPT - 84

Switches
by number
Switches
by name

- 133 -

ALIAS

85. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

85

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 85

Switches
by number
Switches
by name

- 134 -

ALIAS

86. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

86

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 86

Switches
by number
Switches
by name

- 135 -

ALIAS

87. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

87

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 87

Switches
by number
Switches
by name

- 136 -

ALIAS

88. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

88

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

Details

OPT - 88
Switches
by number
Switches
by name

- 137 -

ALIAS

89. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

89

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 89
Switches
by number
Switches
by name

- 138 -

ALIAS

90. Material control - Comdace file contents

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL CONTROL COMDACE FILE CONTENTS

90

Description

This Option Switch controls whether information written to the COMPIPE


Material Control File is per Isometric drawing (COMPIPE Section) or per
Complete Pipeline.
COMDACE is a registered trademark of John Brown Systems Ltd.

Switch Settings

Default for entries in the .MTO (Material Take-Off) file to be per


Isometric Drawing (COMPIPE section).

For entries in the .MTO (Material Take-Off ) file to be per Complete


Pipeline.

Switch Layout

Switch
Position

Either
Setting
Related Program Development Specs.
DEV. NO. 50 - ISOGEN TO COMPIPE LINK.
Related Option Switches.

First
Introduced
Extended
Use

O.S.
9191

Version

Date

5.10

APR 90

6.0

MAR 91

OPT - 90

Switches
by number
Switches
by name

- 139 -

ALIAS

91. Material control - Comdace file controls

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL CONTROL COMDACE FILE CONTROLS

91

Description

Controls the following COMPIPE options :1) Whether User or Client Item Codes are to be used.
2) Whether Short or Long Component Descriptions are generated on all
COMPIPE reports.
3) Whether Pipe Supports are to be included in the COMPIPE .MTO
(Material Take-Off) file.
COMDACE is a registered trademark of John Brown Systems Ltd.
Switch Settings

This Option Switch is in three parts.

SWITCH POSITION 1 - User or Client Item codes.


0
Default for User Item Codes to be used.
1
For Client Item Codes to be used.
SWITCH POSITION 2 - Long or Short Descriptions.
0 or blank Default for Short Component Descriptions to be used.
1
For Long Component Descriptions to be used.
SWITCH POSITION 3 - Pipe Supports in .MTO file.
0 or blank Default for Pipe Supports to be included in the COMPIPE
.MTO file.
1
For Pipe Supports Not to be included.

Switch Layout

Switch
Position

All
All Either
Setting Settings Setting
Related Program Development Specs.
DEV. NO. 50 - ISOGEN TO COMPIPE LINK.
Related Option Switches.

First
Introduced
Extended
Use

O.S.
9090

Version

Date

5.10

APR 90

6.0

MAR 91

OPT - 91

Details
Switches
by number
Switches
by name

- 140 -

ALIAS

92. DXF file units

Options

ISOGEN
Switch Title

Option Switch No.

92

DXF FILE UNITS


Description

This Option Switch is used to identify the 'Units' setting for ALL DXF
format files that are handled by the ISOGEN system.
The actual Files used may be based upon either Imperial (Inches) or Metric
(mm.) units and this Option Switch allows either one to be specified.
This 'Units' value will apply to the following :i) Drawing Underlay (Drawing Frame) DXF files.
ii) Detail Sketch DXF files.
iii) Output (Plot) files generated in DXF format.
All input files used in any run MUST be generated using the same Units.
(As specified using this Option Switch.
Any mis-match in Units that is permitted to occur between the DXF files
generated will result in incorrectly sized drawings.

Switch Settings

Default for Metric Units - mm's.

For Imperial Units - Inches.

Switch Layout

Switch
Position

Either
Setting
Version

Related Program Development Specs.

DEV. NO. 62 - DETAIL SKETCHES


LOCATION FACILITY.
Related Option Switches.

First
Introduced

7.0

Date

OCT 94

Details

Extended
Use

O.S.
7171

OPT - 92

Switches
by number
Switches
by name

- 141 -

ALIAS

93. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

93

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

Details

OPT - 93
Switches
by number
Switches
by name

- 142 -

ALIAS

94. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

94

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

Details

OPT - 94

Switches
by number
Switches
by name

- 143 -

ALIAS

95. Component leg length

Options

ISOGEN
Switch Title

Option Switch No.

95

COMPONENT LEG LENGTH


Description

This Option Switch gives User control over the Plotted Leg Lengths of
Elbows and fitting Tees and Crosses.
This Leg Length control facility does not apply to Fabricated (Pulled) Bends
or Set-On (Stub-In) type Tees or Crosses.
Pipe length scaling proportional to true length.
Switch Settings

SWITCH POSITION 1
0
Default for standard Leg Length of 9mm.
SWITCH POSITION 2
Value
Where Value is set to the required Leg Length in whole
mms. e.g. For a 12mm Leg Length, enter 12.
SWITCH POSITION 3
0
Normal pipe scaling used to determine pipe lengths.
1
Pipe lengths scaled proportionally to actual true lengths.
Warning! - Use the Plotted Leg Length control with care.
Long Leg Lengths take up more space on the drawing and can sometimes
have an adverse effect on the finished isometric.
The maximum value allowed is 18mm.
The minimum value allowed is 6mm.
(Continued overpage)
Switch Layout

Switch
Position

0 or 1
Blank, 1 or 2

Zero

0 or 1

0 or Value

Related Program Development Specs.


DEV. NO. 53 - ISOPLOT PROGRAM UPDATE.

First
Introduced
Extended
Use

Version

Date

6.0

MAR 91

8.5.0

DEC 00

8.11.0

APR 03

OPT - 95

Details
Switches
by number
Switches
by name

- 144 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

95 Cont.

COMPONENT LEG LENGTH


Description

Different connection leg depictions allowed with Multi-Port components.


Display of valve and instrument spindles in either flat or isometric
projection.

Switch Settings

( Continued from previous page )

SWITCH POSITION 4
0

Reserved

SWITCH POSITION 5
0
1

Dotted connection lines on all Multi-port fittings


Dotted connection lines would only be generated when
necessary for picture clarification (example - where 2 or more
ports positioned on the same side with attached pipework
running parallel to each other).
No dotted connection lines shown.

SWITCH POSITION 6 Orientation of valve and instrument spindles.


0
1

Valve and instrument spindles shown flat.


Valve and instrument spindles shown in isometric projection.

Related Program Development Specs.


DEV. NO. 53 - ISOPLOT PROGRAM UPDATE
DEV NO. 91H SPINDLE ENHANCEMENT

First
Introduced
Extended
Use

Version

Date

6.0

MAR 91

8.5.0

DEC 00

8.11.0

APR 03

8.13.0

SEP 06

OPT - 95

Switches
by number
Switches
by name

- 145 -

ALIAS

96. Reserved

Options

ISOGEN
Switch Title

Option Switch No.

RESERVED

96

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 96

Switches
by number
Switches
by name

- 146 -

ALIAS

97. Skew depiction - Individual / overall

Options

ISOGEN
Switch Title

Option Switch No.

SKEW DEPICTION INDIVIDUAL / OVERALL

97

Description

This Option Switch controls how Skew pipe sections containing Branch
connections are depicted in terms of the Skew indication on the isometric.
Such Skews may be shown with either a series of separate Box / Triangle
enclosures - one per Branch, or alternatively, a single overall one.

Switch Settings

Default for a Single Overall Box / Triangle enclosure around the


complete Skew section.

For individual Box / Triangle Skew enclosures to each Branch.

Switch Layout

Switch
Position

Either
Setting
Version

Related Program Development Specs.


DEV. NO. 53 - ISOPLOT PROGRAM UPDATE.
Related Option Switches.

First
Introduced

6.0

Date

MAR 91

Extended
Use

O.S.
9999

Details

OPT - 97
Switches
by number
Switches
by name

- 147 -

ALIAS

98. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

98

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 98
Switches
by number
Switches
by name

- 148 -

ALIAS

99. Skew depiction - Style

Options

ISOGEN
Switch Title

Option Switch No.

SKEW DEPICTION - STYLE

99

Description

Controls whether Skewed pipe sections are drawn with either Box or
Triangle Skew depiction on the isometric, together with the form of Skew
Dimensioning to be used.
A secondary option allows the selection of a mixture of 2D Skew Triangles
and 3D Skew Box depiction.
Skew Dimensioning options offer either normal Dimensioning format
(with witness lines etc.) or a simplified form when using Skew Triangle
format (actual Dimensions positioned along sides of Triangles with no
witness lines)
Switch Settings

This Option Switch is in three parts.

SWITCH POSITION 1 - Skew depiction style + Dimension style.


0

Default for Skew Box depiction with normal dimensioning.


Dimension Line standout as per Option Switch 8.
Skewed Triangle depiction with normal dimensioning.
Dimension Line position as per Option Switch 8.
Skewed Triangle depiction with normal dimensioning.
Dimension Line position as per Option Switch 100.
Skewed Triangle depiction with alternative dimensioning.
Actual dimensions positioned close to sides of Triangle with
no witness lines. Dimensions positioned in relation to
Triangle as set in Option Switch 100

1
2
3

Switch Layout

Blank,
1 or 2

Blank
or 1

Switch
Position

All
Settings

( Continued overpage )
Date

Related Program Development Specs.


DEV. NO. 11 - SKEWED (OFFSET) AND
First
FALLING PIPELINE INDICATION. Introduced

Version

5.4

APR 87

Related Option Switches.

8.11.0

APR 03

Details

OPT - 99

Switches
by number

O.S.
70 O.S. 97
8 8 O.S.
6767 O.S.70
97O.S. 100
100

Extended
Use

Switches
by name

- 149 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

SKEW DEPICTION - STYLE

Switch Settings

99 Cont.

( Continued from previous page )

SWITCH POSITION 2 - Mixture of 3D Boxes and 2D Triangles.


0
1

All Skew indications as set in Switch Position 1.


For a Mixture of Skew indication types.
3D Skews indicated with Boxes.
2D Skews indicated with Triangles.

SWITCH POSITION 3 - Skew Angles


0
1
2

Skew angles not shown.


Skew angles shown with arrow heads on the arc radius.
Skew angles shown without arrow heads on the arc radius.

( NOTE - In order to use this facility the user is required to select


Triangle depiction of the skewed section i.e. Position 1 of Option Switch
99 set to 1, 2 or 3. If Skew Box depiction is selected then no Skew Angles
will be output ).

SWITCH POSITION 4 - Skew Angles - Right Angle indication


0
1

No Right Angle Indicators shown on Skew Triangles.


Right Angle Indicators output on Skew Triangles.

NOTE - Does not apply if Skew box depiction used.

Related Program Development Specs.

67

70

97

Details

100
OPT - 99

Switches
by number
Switches
by name

- 150 -

ALIAS

100. Skew depiction - Dimension line standout

Options

ISOGEN
Switch Title

Option Switch No.

SKEW DEPICTION DIMENSION LINE STANDOUT

100

Description

Allows the Dimension Line Standout distance used on Box or Triangle Skew
Dimensions to be varied from the value set in Option Switch 8.

Switch Settings

Default such that if Option Switch 99 = 0, 1, 2, 10, 11 or 12


then the Dimension Line Standout Setting defined in Option
Switch 8 is used.
Or,
if Option Switch 99 = 3, or 13 then the default Dimension
Position is 4 mm.

Value

Where Value is an alternative Dimension Line Standout in 1/10


mm. e.g. 120 = 12 mm.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
DEV. NO. 11 - SKEWED (OFFSET) AND
FALLING LINE INDICATION.
Related Option Switches.

Version
First
Introduced

5.4

Date

APR 87

Extended
Use

O.S.
9999

Details

OPT - 100

Switches
by number
Switches
by name

- 151 -

ALIAS

101. Skew depiction - Triangle hatching

Options

ISOGEN
Switch Title

Option Switch No.

SKEW DEPICTION TRIANGLE HATCHING

101

Description

Controls the features of the Skew Triangle Hatching facility.


Hatching On / Off , the pitch and maximum length of the Hatching lines to
be plotted can also be controlled.
Switch Settings

This Option Switch is in two parts.

SWITCH POSITIONS 1 & 2 - Hatching On / Off + Hatch Spacing.


0
Default to set Skew Hatching Off.
1
To set Skew Hatching On with a default Hatch Line pitch of
1 mm.
Value
Where Value equals an alternative Hatch Line pitch in 1/10 mm.
e.g. For 2 mm Hatch Line pitch set 20.
SWITCH POSITIONS 3 & 4 - Hatch Line Cut-Off Length.
Blank
Default for No Hatch Line Cut-Off value.
All Triangles will be fully Hatched.
Value
Where Value equals Hatch Line Cut-Off Length in whole mm.
e.g. For 25 mm cut-off value, enter 25.
In this case Hatch lines in excess of 25 mm. long will not be
plotted. This gives a partial Hatched effect.

Switch Layout

Blank or
Value

Switch
Position

All
Settings
Version

Related Program Development Specs.


DEV. NO. 11 - SKEWED (OFFSET) AND FALLING
PIPELINE INDICATION.
DEV. NO. 53 - ISOPLOT PROGRAM UPDATE.

Related Option Switches.

First
Introduced
Extended
Use

O.S.
9999

Date

5.4

APR 87

6.0

MAR 91

OPT - 101

Details
Switches
by number
Switches
by name

- 152 -

ALIAS

102. Skew depiction - Hatching clearance

Options

ISOGEN
Switch Title

Option Switch No.

SKEW DEPICTION HATCHING


CLEARANCE

102

Description

Controls the physical size of the Un-hatched Gaps (White Areas) to be left
local to the Pipeline, Pipeline In-line components and any Dimensions or
Text elements that fall within any Skew Triangle Hatching.
Switch Settings

This Option Switch is in three parts.

SWITCH POSITIONS 1 & 2 - Gap local to Pipeline.


0
Default for Gap local to Pipeline of 2.5 mm.
Value
Where Value is an alternative Gap in 1/10 mm.
SWITCH POSITIONS 3 & 4 - Gap local to In-line Components.
0 or blank Default for Gap local to In-line Components of 2.5 mm.
Value
Where Value is an alternative Gap in 1/10 mm.
SWITCH POSITIONS 5 & 6 - Gap local to Dimensions and Text.
Blank
Default for Gap local to Dimensions/Text of 1.5 mm.
Value
Where Value is an alternative Gap in 1/10 mm

Switch Layout

Blank or
Value

Blank, Zero
or Value

Switch
Position

Zero or
Value
Version

Related Program Development Specs.


DEV. NO. 53 - ISOPLOT PROGRAM UPDATE.
Related Option Switches.

First
Introduced

6.0

Date

MAR 91

Extended
Use

101
O.S.
101

Details

OPT - 102
Switches
by number
Switches
by name

- 153 -

ALIAS

103. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

103

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 103

Switches
by number
Switches
by name

- 154 -

ALIAS

104. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

104

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 104
Switches
by number
Switches
by name

- 155 -

ALIAS

105. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

105

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 105
Switches
by number
Switches
by name

- 156 -

ALIAS

106. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

106

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 106
Switches
by number
Switches
by name

- 157 -

ALIAS

107. Spare switch

Options

ISOGEN
Switch Title

Option Switch No.

SPARE SWITCH

107

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 107

Switches
by number
Switches
by name

- 158 -

ALIAS

108. Pipeline splitting - In tube

Options

ISOGEN
Switch Title

Option Switch No.

PIPELINE SPLITTING - IN TUBE

108

Description

Allows the User to control the actions to be taken by the program whenever
the ISOGEN Automatic Pipeline Split facility selects a Split Point that is
located in a straight length of Tube.
There are three options, as described below.

Switch Settings

Default for Pipeline Splitting to function as normal when the Split


point occurs along a section of Tube. The relevant Split Point
information will be passed back to the 3D Design System via the
Isometric Repeatability File, if being used.
If a Pipeline Split occurs along a section of Tube, the Warning
Message - "UNACCEPTABLE SPLIT POINT" is written to the
Message File. No plots are produced and No information will be
written to the Isometric Repeatability File for the Pipeline.
If a Pipeline Split occurs along a section of Tube, the Warning
Message - "UNACCEPTABLE SPLIT POINT" is written to the
Message File. Plots are produced with the message
"UNACCEPTABLE SPLIT" plotted at the top of each affected
drawing. No information will be written to the Isometric
Repeatability File for the Pipeline.

Switch Layout

Switch
Position

All
Settings
Version

Related Program Development Specs.


DEV. NO. 48 - ISOMETRIC REPEATABILITY.
Related Option Switches.

First
Introduced

6.0

Date

MAR 91

Details

Extended
Use

O.S.
109
109

OPT - 108

Switches
by number
Switches
by name

- 159 -

ALIAS

109. Repeatability file content

Options

ISOGEN
Switch Title

Option Switch No.

REPEATABILITY FILE CONTENT

109

Description

Controls the type of Repeatability Information that is passed back to the


host 3D Design System in the Isometric Return file.
Also controlled is the actual Type of Return file that is required. The File
Type options are :1) An old style system data file that only contains 'Successful Plot'
information. (File identifier is FOR052).
2) A new style Return File that is generated as a system data file. (File
identifier is FOR052).
3) A new style Return File that has a User defined file name.
4) A new style Return File that has additional spool information.
5) Option for ASCII output.
Switch Settings This Option Switch is in eight parts.

SWITCH POSITION 1 - Return File Type.


0

Default for Standard Return File type (FOR052) containing


just a list of successfully processed pipelines.
For New Style format using a User Named file or FOR052
System data file if there is No User Named file.
For New Style Repeatability File containing new records for
spool information.
ASCII old style.
ASCII new style.

1
2
3
4

Switch Layout

Switch
Position

Either Setting
Date
Version
Related Program Development Specs.
DEV. NO. 48 - ISO REPEATABILITY Phase I.
First
DEV. NO. 58 - ISO REPEATABILITY Phase II.
MAR 91
Introduced 6.0
DEV.NO. 86H - REPEATABILITY FILE UPGRADE
Extended
Use

Related Option Switches.

7.0

OCT 93

8.5.4

DEC 00

OPT - 109

ISSUE 3

- 160 -

Details
Switches
by number
Switches
by name

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

REPEATABILITY FILE CONTENT

109 Contd.

SWITCH POSITION 2 - Data Extraction Start Point


0
Default for the Data Extraction Start Point not to be written
to the Return File.
1
For Data Extraction Start Point to be written to the Return
File.
SWITCH POSITION 3 - Pipeline Split Point Information
0
Default for Split Point Information Not to be written to the
Return File.
1
For the Split Point to be written to the Return File.
SWITCH POSITION 4 - Spool Number Identifier Information
0
Default for Spool Number Identifiers not to be written to the
Return File.
1
For Spool Number Identifies to be written to the Return File.
2
For full alphanumeric Spool Identifiers to be written to the
Return File. (Maximum of 4 characters).
SWITCH POSITION 5 - Component Information
0
Default for Component Information not to be written to the
Return File.
1
For Component Information to be written to the Return File.
2
For full alphanumeric Component Information to be written
to the Return File. (Maximum of 4 characters).
SWITCH POSITION 6 - By-pass component re-ordering
0
Re-ordering of components at By-pass closure points to be
done.
1
No re-ordering of components at By-pass closure points.
SWITCH POSITION 7 - Weld Number Information
0
Default for Weld Number Information not to be written to
the Return File.
1
For Weld Number Information to be written to the Return
File.
SWITCH POSITION 8 - Material List Part Number Information
Blank
Default for Material List Part Number Information not to be
written to the Return File.
1
For Material List Part Number to be written to the Return
File.

- 161 -

109

Details
Switches
by number
Switches
by name

ALIAS

110. Ghost gaps

Options

ISOGEN
Switch Title

Option Switch No.

GHOST GAPS

110

Description

Controls the plotted length of a Ghost Gap element.


(A Ghost Gap element is a physical 'Gap' on the plotted isometric that can
be used when generating individual Pipeline isometrics, or as a link
between related, but unconnected Pipelines on a 'System' type isometric).

Switch Settings

Default for the normal Minimum Gap as controlled by the


ISOGEN program.

Value

Where Value is the User defined Minimum Gap dimension in


whole mm's.

Notes.
The Smallest allowable Value is 18 mm.
The Largest allowable Value is 60 mm.
The program will default to using the appropriate Maximum Value if a
setting outside these limits is detected.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
DEV. NO. 47 - GHOST GAP FACILITY.

First
Introduced

Version

Date

5.9

MAR 90

Extended
Use

Details

OPT - 110

Switches
by number
Switches
by name

- 162 -

ALIAS

111. Nozzles - Dotted

Options

ISOGEN
Switch Title

Option Switch No.

111

NOZZLES - DOTTED
Description

Controls whether or not Equipment Nozzle indicators are plotted (in


dotted line style) on the isometric drawing.
Also controls the calculation of of Nozzle Axes directions and insertion of
this information into the PCF (Piping Component File) when using the
PCFGEN program.

Switch Settings

This Option Switch is in two parts.

SWITCH POSITION 1 - Dotted Nozzle indication.


0

Default to suppress Dotted Nozzles.

To have Dotted Nozzles plotted on the isometric.

SWITCH POSITION 2 - Nozzle Axis direction calculation.


Blank

No calculation of Nozzle Axis direction.

Nozzle Axis direction calculated and inserted into the PCF.

Switch Layout

Blank
or one

Switch
Position

Either
Setting

Related Program Development Specs.


DEV. NO. 4 - DOTTED NOZZLE FACILITY.

First
Introduced
Extended
Use

ISSUE 2

Version

Date

2.0

AUG 85

PCFGEN
JUL 95
1.0

OPT - 111

Details
Switches
by number
Switches
by name

- 163 -

ALIAS

112. Flow arrows - Pipeline

Options

ISOGEN
Switch Title

Option Switch No.

FLOW ARROWS - PIPELINE

112

Description

This Option Switch controls the use of Flow Arrows that are plotted
directly on the pipe. Their purpose is to show the Pipeline's Fluid or Gas
flow Direction.
Note. A separate type of Flow Arrow which is plotted alongside in-line
fittings may also be used, either as well as, or instead of this one on Pipe.

Switch Settings

Default for Pipeline Flow Arrows to be plotted at the default


scale factor of 8.

For Pipeline Flow Arrows to be suppressed.

Value

For Pipeline Flow Arrows to be plotted at an alternative scale


factor in the range Value 5 to 15 inclusive.
(Value 5 gives smaller arrows, 15 larger).

Note. This type of Flow Arrow can only be generated if the relevant
information is included in the Pipeline Input Data File.

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
DEV. NO. 7 - USER POSITIONED FLOW
ARROWS.
Related Option Switches.

First
Introduced

Version

Date

3.0

APR 86

Extended
Use

O.S.
1717

Details

OPT - 112
Switches
by number
Switches
by name

- 164 -

ALIAS

113. Material control - Pipeline identification

Options

ISOGEN
Switch Title

Option Switch No.

MATERIAL CONTROL PIPELINE IDENTIFICATION

113

Description

This Option Switch controls the format of the Pipeline Reference (that is,
Name) that is passed to the ISOGEN Material Control Transfer (MATC)
File.

Switch Settings

Default to pass the Full Pipeline Reference as contained in the


PIPELINE-REFERENCE record.
e.g. Pipeline Reference 6-LNG-6412A-CT15 in the Design
Database remains the same in the Material Control file.

To formulate a revised Pipeline Reference by stripping off the


characters outside the first and last "-" delimiting character of
the Pipeline Reference, removing the central "-" delimiter, and
then passing the remaining character string.
e.g. 6-LNG-6412A-CT15 is changed to LNG6412A in the
Material Control file.
Note. This is a very specific facility and will not function if the
PIPELINE-REFERENCE in the Pipeline Input Data File is not
in the exact form described above.

Switch Layout

Switch
Position

Either
Setting
Related Program Development Specs.
First
Introduced

NONE

Version

Date

1.0

APR 83

Extended
Use

OPT - 113
Switches
by number
Switches
by name

- 165 -

ALIAS

114. Specification break indication

Options

ISOGEN
Switch Title

Option Switch No.

SPECIFICATION BREAK INDICATION

114

Description

This Option Switch controls the method to be used for the indication of
Specification Breaks (Specification Changes) on the isometric.
Two optional methods are available :i) Single Specification indication.
B oxed message consisting of the New Specification Reference pointing to
the position on the Pipeline where the change occurs.
ii) Two Specification indication.
Two boxed messages containing the Current and New Specification
References, positioned at the point on the Pipeline where the change
occurs.
Enclosure type of Specification Break can also be specified.
Switch Settings

SWITCH POSITION 1 Specification Break Style


0 Default to obtain the single Specification Break indication box.
1 To obtain the dual Specification Break indication boxes.
SWITCH POSITION 2 Specification Break Enclosure
0 Specification Break in Square Ended box - default
1 Specification Break without any Enclosure
2 Specification Break in Diamond Ended box
3 Specification Break in Round Ended box
4 Specification Break in Hexagonal Ended box

Switch Layout

Blank or
setting

Switch
Position

Either
Setting
Version

Date

First
Introduced

1.0

APR 83

Extended
Use

5.0

OCT 86

9.2

MAR 09

Related Program Development Specs.


DEV. NO. 15 - SPEC. BREAK INDICATION.

OPT - 114

Details
Switches
by number
Switches
by name

- 166 -

ALIAS

115. Tolerance - Angle offset

Options

ISOGEN
Switch Title

Option Switch No.

115

TOLERANCE - ANGLE OFFSET


Description

This Option Switch controls how small Angular deviations detected in the
Pipeline Input Data File are to be interpreted and acted upon. These
deviations can lead to small unwanted Skews being generated on the
isometric.
The User may define an Angular cut-off value with this switch whereby any
Skew that is found to have an angular deviation below this value is ignored
by the program and hence not treated as a Skew.
Switch Settings

Default for No Angular Offset Tolerance to be set.

Value

Where Value is set to the required angle tolerance in 1/100 th.


degree.
e.g. For 0.5 degree cut-off, enter 50 .

Switch Layout

Switch
Position

Zero or
Value
Related Program Development Specs.
DEV. NO. 21 - SKEW BOX CUT-OFF
TOLERANCE.

First
Introduced

Version

Date

4.2

JUL 86

Extended
Use

Details

OPT - 115
Switches
by number
Switches
by name

- 167 -

ALIAS

116. Tolerance - Dimension offset

Options

ISOGEN
Switch Title

Option Switch No.

116

TOLERANCE - DIMENSION OFFSET


Description

This Option Switch controls how small Dimensional deviations detected in


the Pipeline Input Data File are to be interpreted and acted upon. These
deviations can lead to small unwanted Skews being generated on the
isometric.
The User may define a Dimensional cut-off value with this switch whereby
any offset co-ordinate numerically below this value is ignored by the
program and hence will not generate a Skew at this point.
Controls tolerance applied to connecting components.
Switch Settings

SWITCH POSITIONS 1-3 Small dimensional deviations


0
Value

Default for No Dimensional Offset Tolerance to be set.


Where Value is set to the required dimensional tolerance in
1/100th millimetre. E.g. For 1.0mm cut-off, enter 100.

SWITCH POSITIONS 4-6 Idfgen connection tolerance


0
Value

Default for No connection tolerance to be set


Where Value is set to the required connection tolerance in
1/100th millimetre. E.g. For 1.0mm cut-off, enter 100.

Backward compatibility To avoid problems where this control is set as a


single value (i.e. no tolerance is set in Pos 4-6), Idfgen will continue to use
Pos 1-3 to determine the connection tolerance.
Switch Layout

Related Program Development Specs.


DEV. NO. 21 - SKEW BOX CUT-OFF TOLERANCE First
9.0.0 RELEASE NOTES
Introduced
Extended
Use

Switch
Position

Version

Date

4.2

JUL 86

9.0

MAY 08

Details

OPT - 116
Switches
by number
Switches
by name

- 168 -

ALIAS

117. Dimension round off

Options

ISOGEN
Switch Title

Option Switch No.

DIMENSION ROUND OFF

117

Description

This Option Switch controls the "Dimension Round Off Carry-Over


function which is used to control how remainders are handled when
dimensions are being calculated and output on the isometric.
At Branch locations, this Option Switch permits the remainder part of a
dimension either to be carried over and added to the next dimension, or
discarded.
An Override carry-over option beyond current component is also available
Switch Settings

Default for rounding off dimensions to + or - 1mm or 1/16th


inch and carrying over any remainder to the next dimension.

For rounding off dimensions to + or - 1mm or 1/16th inch with


No carry-over of the remainder beyond a branch intersection

For rounding off dimensions to + or - 1mm or 1/16th inch with


No carry-over of the remainder beyond a current component

Switch Layout

Switch
Position

Either
Setting
Related Program Development Specs.
DEV. NO. 23 - SUPPRESSION OF DIMENSION
ROUND OFF CARRY-OVER.

First
Introduced
Extended
Use

Version

Date

5.2

MAR 87

8.11.0

APR 03

OPT - 117

Switches
by number
Switches
by name

- 169 -

ALIAS

118. Dimensions - Overall

Options

ISOGEN
Switch Title

Option Switch No.

118

DIMENSIONS - OVERALL
Description

This Option Switch controls the use of Overall Dimensions.


The controllable options are whether Overall Dimension are to be plotted
or not, and if they are, which type. Also controllable is the Dimension Line
Stand-Out distance.
Overall Dimensions to Valve Centres are only available to Valves that have
a Spindle.

Switch Settings

This Option Switch is in two parts.


SWITCH POSITION 1 - Overall Dimensions On /Off and Type.
0
Default for No Overall Dimensions.
1
For Overall Dimensions On - going across Branches
(e.g. Tees, Olets and Crosses).
2
For Overall Dimensions On - stopping at Branches
(e.g. Tees, Olets and Crosses).
3
For Overall Dimensions On - going to Valve Centres and going across
Branches (e.g. Tees, Olets and Crosses).
4
For Overall Dimensions On - going to Valve Centres but stopping at
Branches (e.g. Tees, Olets and Crosses).
(Continued over page)

Switch Layout

Switch
Position

Blank or
All
Value Settings
Related Program Development Specs.
DEV. NO. 36 - OVERALL DIMENSIONS TO
CENTRE-LINE OF VALVES.
DEV. NO. 53 - ISOPLOT PROGRAM UPDATE.

Version

Date

First
Introduced

5.9

MAR 90

Extended
Use

7.0

OCT 93

Details

OPT - 118
Switches
by number
Switches
by name

- 170 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

118 Contd.

DIMENSIONS - OVERALL
Description

Switch Settings

(Continued from previous page)

SWITCH POSITIONS 2 & 3 - Overall Dimension Standout.


Blank
Default for No Overall Dimension Standout to be set.
Program default will be used for all Overall Dimensions.
Value

Value is set to the User Specified Overall Dimension Standout


distance in whole mm's.
e.g. For 22 mm. set 22.

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

Details

OPT - 118
Switches
by number
Switches
by name

- 171 -

ALIAS

119. Dimensions / elevations - Vertical

Options
Options

ISOGEN
ISOGEN
Switch Title
Switch Title

Option Switch No.


Option Switch No.

119
119

DIMENSIONS / ELEVATIONS - VERTICAL


DIMENSIONS / ELEVATIONS - VERTICAL

Description
Description
This Option Switch controls how Vertical pipe positions are indicated on the

This Option Switch controls how Vertical pipe positions are indicated on the
isometric.
isometric.
These may be indicated either with normal Pipe Dimensions, in the form of
These may be indicated either with normal Pipe Dimensions, in the form of
vertical Co-ordinate Elevation (EL.) values, or a combination of both types.
vertical Co-ordinate Elevation (EL.) values, or a combination of both types.
Dimensioning of Tee Bend/Elbows to Connection or Intersection Points.
Dimensioning of Tee Bend/Elbows to Connection or Intersection Points.

Switch Settings
Switch Settings

SWITCH POSITION 1 Vertical dimensions and elevations.


SWITCH POSITION 1 Vertical dimensions and elevations.
0
0
1
1
2
2

Default for normal Vertical pipe Dimensions.


Default forare
normal
Vertical pipe
Dimensions.
Elevations
also indicated
at intersection
points when level
Elevations
are
also
indicated
at
intersection
points when level
changes.
changes.
For all vertical pipe dimensions to be suppressed and replaced by
For all vertical
to be suppressed
and replaced
elevations
in thepipe
formdimensions
of text messages
at ALL positions
where by
elevations
in
the
form
of
text
messages
at
ALL
positions
where
dimensions would normally be output.
dimensions
would
normally
be
output.
For vertical dimensions and elevnations output at normal
For vertical dimensions
dimensioning
positions. and elevations output at normal
dimensioning positions.

SWITCH POSITION 2 Tee Bend/Elbow Dimensioning


SWITCH POSITION 2 Tee Bend/Elbow Dimensioning
0
10
1

Dimension Tee Bend/Elbow branch from Connection Point.


Dimension Tee
Tee Bend/Elbow
Bend/Elbow branch
branch from
from centreline
Connection
Point.
Dimension
Intersection
Dimension
Tee
Bend/Elbow
branch
from
centreline
Intersection
Point
Point

Switch Layout
Switch Layout

6
6

5
5

4
4

3
3

2
2

1
1

0
0

Switch
Switch
Position
Position

Settings
Settings
Related Program Development Specs.
Related Program Development Specs.
DEV. NO. 18 - IMPROVED DIMENSIONING
DEV. NO.
18 - IMPROVED
8.13.0
RELEASE
NOTES DIMENSIONING
8.13.0 RELEASE NOTES

Version
Version

First
1.0
First
Introduced
Introduced 1.0
Extended
5.0
Extended
Use
5.0
8.13.0
Use

Date
Date

APR 83
APR 83
OCT 86
OCT 86
SEP 06
8.13.0 SEP 06

OPT - 119
OPT - 119

Details
Switches
by number
Switches
by name

- 172 -

ALIAS

Options
Options

ISOGEN
ISOGEN
Switch Title
Switch Title

Option Switch No.


Option Switch No.

119
119

DIMENSIONS / ELEVATIONS - VERTICAL


DIMENSIONS / ELEVATIONS - VERTICAL

Description
Description
This Option Switch controls how Vertical pipe positions are indicated on the

Suppression
isometric. of Reference dimensions.
Dimensioning
of Fabrication
between
sections
of pipe.
These may be indicated
eitherwelds
with in
normal
Pipe
Dimensions,
in the form of
th
Dimensioning
(metric
only)
of
gaskets
to
nearest
10
mm.
vertical Co-ordinate Elevation (EL.) values, or a combination of both types.
Dimensioning
Plates.to Connection or Intersection Points.
Dimensioning of
of Penetration
Tee Bend/Elbows
Switch Settings
Switch Settings

SWITCH POSITION 1 Vertical dimensions and elevations.


SWITCH POSITION 3 Suppression of Reference dimensions
0
0
1

Default for normal Vertical pipe Dimensions.


Output Reference dimensions.
Elevations are also indicated at intersection points when level
Suppress Reference dimensions.
changes.
1
For all vertical pipe dimensions to be suppressed and replaced by
SWITCH POSITION 4 Fabrication weld between pipe.
elevations in the form of text messages at ALL positions where
dimensions would normally be output.
0
Suppress dimension to fabrication welds between sections of pipe.
2
For vertical dimensions and elevnations output at normal
1
Dimension to fabrication welds between sections of pipe.
dimensioning positions.
SWITCH POSITION 5 Gasket dimensioning to nearest 10th mm.
SWITCH POSITION 2 Tee Bend/Elbow Dimensioning
0
0
1
1

Output gasket dimensions to nearest mm.


Dimension Tee Bend/Elbow branch from Connection
Point.
Output gasket dimensions to the nearest 10th mm.
Dimension Tee Bend/Elbow branch from centreline Intersection
Point
SWITCH POSITION 6 Penetration Plate dimensioning.
0

Switch Layout

Pipes passing through Penetration Plates dimensioned


3
2
6 adjacent
5
4
1
Switch
from
Plate
face.
Position
Pipes passing through Penetration Plates
dimensioned
0
from same Plate face.

Settings
Related Program Development Specs.
Related Program Development Specs.
DEV.
18 - IMPROVED
8.13.1NO.
RELEASE
NOTES DIMENSIONING
8.13.0 RELEASE NOTES
9.0.0 RELEASE NOTES

Version
Version

First
1.0
First
Introduced
Introduced
Extended
5.0
Extended 8.13.1
Use
8.13.0
Use

9.0.0

Date
Date

APR 83
OCT 86
MAY
07
SEP 06
MAY 08

OPT - 119
OPT - 119

Switches
by number
Switches
by name

- 173 -

ALIAS

120. Tapping - Branch scale

Options

ISOGEN
Switch Title

Option Switch No.

120

TAPPING - BRANCH SCALE


Description

This Option Switch controls the plotted size of Tapped Branches. A Tapped
Branch is a collection of components attached to a connection Tapping Point.
This Switch is in 2 sections:
i) Tapped Branches on actual Fitting Components i.e. Valves, Flanges etc.
ii) Tapped Branches on pipe Type Components i.e. Elbows, Tees, Pipe etc.
The components in a Tapped Branch may be scaled up or down from the
size used for the main Pipeline.
Switch Settings

This Option Switch is in two parts.


SWITCH POSITION 1, 2 & 3 - Tapped Branches on Fitting Components.

Value

Default for No Tapped Branch scaling.


i.e. Tapped Branches shown the same size as the main Pipeline
(100%).
Where Value is a number that represents an alternative
Tapped Branch scaling factor.
e.g. Enter 110 to increase scaling, 90 to decrease scaling.
(50% is the minimum recommended value).

SWITCH POSITION 4 & 5 - Tapped Branches on Pipe type Components.


Blank
Default for Tapped Branch scaling at 65% of main Pipeline size.
Value

Where Value is a number that represents an alternative


Tapped Branch scaling factor.
e.g. Enter 80 to increase scaling, 45 to decrease scaling.

Switch Layout

Blank, Zero
or Value

Switch
Position

Zero or
Value
Date

Related Program Development Specs.


DEV. NO. 9 - FITTING TAP FACILITY.
First
DEV. NO. 70A - TAPS ON PIPE COMPONENTS Introduced

Version

5.0

MAR 87

Related Option Switches.

7.14

MAR 98

Extended
Use

O.S.
121 O.S.
122
121
122

ISSUE 3

Details

OPT - 120
Switches
by number
Switches
by name

- 174 -

ALIAS

121. Tapping - Branch dimensions

Options

ISOGEN
Switch Title

Option Switch No.

121

TAPPING - BRANCH DIMENSIONS


Description

This Option Switch controls the Dimensioning of Tapped Branches. A Tapped


Branch is a collection of components attached to a connection Tapping Point.
This Switch is in 2 sections:
i) Tapped Branches on actual Fitting Components i.e. Valves, Flanges etc.
ii) Tapped Branches on Pipe Type Components i.e. Elbows, Tees, Pipe etc.
Tapped Branches may be output on the isometric in either dimensioned, undimensioned or partially dimensioned form.
Switch Settings

This Option Switch is in three parts.


SWITCH POSITION 1 - Tapped Branches on Fitting Components.
0
1
2

Default for Tapped Branch Dimensions On - as set for the main


pipeline.
For Tapped Branch Dimensions Off.
For Tapped Branch Dimensions Off except for those on Pipe and
Pipe Type Components.

SWITCH POSITION 2 - Tapped Branches on Pipe Components.


Blank
1
2

Default for Tapped Branch Dimensions Off.


Tapped Branch Dimensions On.
For Tapped Branch Dimensions Off except for those on Pipe and
Pipe Type Components.

SWITCH POSITION 3 - Tapped Branches on Pipe Fittings


0
Tapped Branches on pipe fittings not dimensioned.
1
Tapped Branches on pipe fittings dimensioned.
Switch Layout

Switch Position
Zero
or Value

Blank
or Value
Related Program Development Specs.
DEV. NO. 9 - FITTING TAP FACILITY.
DEV. NO. 70A - TAPS ON PIPE COMPONENTS
9.0.0. RELEASE NOTES
Related Option Switches.

120
122
O.S.
120 O.S.
122
ISSUE 3

Version

Date

First
Introduced

5.2

MAR 87

Extended
Use

7.14

MAR 98

9.0

MAY 08

Details

OPT - 121
Switches
by number
Switches
by name

- 175 -

ALIAS

122. Tapping - Branch co-ordinates

Options

ISOGEN
Switch Title

Option Switch No.

TAPPING - BRANCH CO-ORDINATES

122

Description

This Option Switch controls the output of Co-ordinates at Tapped Branch


connection points.
(i.e. The point on the host component that the Tapped Branch is connected
to).

Switch Settings

0
1
2

Default for Tapping Point connection Co-ordinates Not to be


plotted.
For Tapping Point connection co-ordinates to be plotted.
Tapping Point connection relative to component origin.

Switch Layout

0
Blank
or Value

Switch
Position

Either
Setting

Related Program Development Specs.


DEV. NO. 9 - FITTING TAP FACILITY.
DEV.NO.73B - TANGENTIAL BRANCH
CONNECTIONS
Related Option Switches.
O.S. 120 O.S. 121

Version

Date

First
Introduced

5.2

MAR 87

Extended
Use

8.8.0

JUN 01

Details

OPT - 122
Switches
by number
Switches
by name

- 176 -

ALIAS

123. Instrument ID enclosure

Options

ISOGEN
Switch Title

Option Switch No.

INSTRUMENT ID ENCLOSURE

123

Description

This Switch controls the plotting of Instrument Name enclosures which may
be Balloons, a variety of other box type enclosures, or no enclosure.
In the case of Balloon type enclosures, when switched On, the Balloon
diameter is always generated at a size that will enclose the maximum
number of characters set in the Option Switch.
Reference Names output in circular enclosures.

Switch Settings

This Option Switch is in 4 parts.

SWITCH POSITION 1 - For Balloon type enclosures.


0
Default for No Balloon around the Instrument Name.
All the following values represent the number of plotted characters
permitted on either line within the balloon (Maximum of two lines
allowed).
1
For 1 character maximum on each line.
2
For 2 characters maximum on each line.
3
For 3 characters maximum on each line.
4
For 4 characters maximum on each line.
5
For 5 characters maximum on each line.
Note. A two line Name output is derived by inputting a $ character in the
Name at the point a new-line is required.
(Continued overpage).
Switch Layout

Zero or Value

Blank or
Value

Unused

Switch
Position

Zero or
Value
Version

Date

First
Introduced

1.0

APR 83

Extended
Use

5.2

MAR 87

7.0

OCT 93

Related Program Development Specs.


DEV. NO. 10 - INSTRUMENT BALLOON
FACILITY.
VERSION 7 - RELEASE NOTES.

OPT - 123

Details
Switches
by number
Switches
by name

- 177 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

INSTRUMENT ID ENCLOSURE

123 Contd.

SWITCH POSITION 2 - Currently Unused.


SWITCH POSITION 3 - Instrument enclosures.
0
1
2
3
4
5
6
7
8

No Enclosure
Diamond Ended Box Enclosure
Round Ended Box Enclosure
Triangular Enclosure (2 chars max.) *
Diamond Enclosure (3 chars max.) *
Square Ended Box Enclosure
Circular Enclosure
Elliptical Enclosure
Hexagonal Enclosure

* Because these two enclosures cannot be elongated, there is a limit on the


number of characters that can be accommodated use with care!
Notes.
i)

When using any of the Box type enclosures, Switch Position 1 must be
set to zero.
ii) A two line Name output is derived by inputting a $ character in the
Name at the point a new-line is required.
SWITCH POSITION 4 - Location Point - message enclosures.
0
1

Location Point message preceded by special text symbol.


Location Point message in square ended box enclosure.

SWITCH POSITION 5 Reference Names circular enclosures.


0
x

Reference Names output along Steelwork Reference lines.


Size of circular enclosure specified in number of standard chars.
Version

Related Program Development Specs.


DEV 91M. INSTRUMENT NAMES
9.0.0 RELEASE NOTES

Date

First
Introduced
Extended
Use

8.13.0 SEP 06
9.0.0

MAY 08

OPT - 123

Details
Switches
by number
Switches
by name

- 178 -

ALIAS

124. Flange rotation angles

Options

ISOGEN
Switch Title

Option Switch No.

FLANGE ROTATION ANGLES

124

Description

This Switch controls the output of Flange Rotation Angles that are used by
the Fabricator when welding on Flanges that have to be rotated away from
the normal off centres axes.
Although the facility may be used on all types of isometrics, it is of
particularly benefit on Spool Isometrics.
When the facility is switched on there are a variety of enclosure box styles
that can be used for the output of Flange Rotation Angles on the isometric.
Switch Settings

This Option Switch is in 2 parts.

SWITCH POSITION 1 - Flange Rotation Angles plotted or not.


0
Default for No Flange Rotation Angles.
1
For Flange Rotation Angles to be output.
SWITCH POSITION 2 - Enclosure Box type.
Blank
Default for Un-Boxed Angle output.
1
For Diamond ended enclosure box.
2
For Round ended enclosure box.
3
For Square ended enclosure box.

Switch Layout

Switch
Position

Blank or Either
Value
Setting
Version

Related Program Development Specs.


DEV. NO. 63(B) - FLANGE ROTATION ANGLES. First
Introduced

7.1

Date

JUN 94

Extended
Use

Details

OPT - 124
Switches
by number
Switches
by name

- 179 -

ALIAS

125. Reserved

Options

ISOGEN
Switch Title

Option Switch No.

RESERVED

125

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 125

Switches
by number
Switches
by name

- 180 -

ALIAS

126. Reserved

Options

ISOGEN
Switch Title

Option Switch No.

RESERVED

126

Description

Switch Settings

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

OPT - 126

Switches
by number
Switches
by name

- 181 -

ALIAS

127. Isogen version / run date

Options

ISOGEN
Switch Title

Option Switch No.

ISOGEN VERSION / RUN DATE

127

Description

This Switch controls the optional plotting of the ISOGEN Program Version
Banner together with the Run Date and generation time of the isometric.
When switched On, this information is plotted on a single line located at the
bottom Left Hand corner of the isometric, but inside any Cut Marks that
may be present.
Alternatively, the Banner may be located just below the bottom outer line
of the Drawing Frame.
Switch Settings

Default for the Banner Not to be plotted.

Banner to be plotted.

Special value for Alias Ltd laserprinter.


(Moves the Banner inwards from the edge of the plot to prevent the
printer from 'clipping' the message).

Switch Layout

Switch
Position

Either
Setting
Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

Details

OPT - 127

Switches
by number
Switches
by name

- 182 -

ALIAS

128. Fab friendly isometrics

Options

ISOGEN
Switch Title

Option Switch No.

FAB FRIENDLY ISOMETRICS ( FFI )

128

Description

This Switch controls three FFI conditions :1) The Weld Type automatically inserted at Break Points between FFI's.
2) Which FFI Gaskets & Bolts should be associated with when an FFI Split
occurs at a Flanged connection.
3) FFW Cutting Allowance association - to which side of a FFW which is
located in Pipe should any Allowance be added to.
Switch Settings

This Option Switch is in 3 parts.


SWITCH POSITION 1 - Type of Weld inserted at FFI Break Point.
0
Default for Site Weld (SKEY = WS).
1
For User defined choice - A Pop Up Menu will be displayed for
the User to select the Weld choice (or No Weld).

SWITCH POSITION 2 - Controls which FFI the generated Gaskets &


Bolts
should be associated with when an FFI Split
occurs at a Flanged connection.
Blank
Default for program to always attach the Gaskets & Bolts to
a detected flange. On a pair of Flanges, this will be the First
Flange.
1
For User defined choice at most Flange positions.
(Where a Flange is positioned at the 'End' of Pipeline or
Branch then No choice is necessary).
(Continued overpage)

Switch Layout

Blank
or one

Switch
Position

Zero, blank Zero or


or one
one
Version

Related Program Development Specs.


First
Introduced

7.3

Date

SEP 95

Extended
Use

ISSUE 2

Details

OPT - 128
Switches
by number
Switches
by name

- 183 -

ALIAS

Options

ISOGEN
Switch Title

Option Switch No.

FAB FRIENDLY ISOMETRICS ( FFI )

128 Contd.

Description

Switch Settings

(Continued from previous page)

SWITCH POSITION 3 - FFW Cutting Allowance Association.


0
Default to have any Allowance added to the First piece of pipe found
in the Piping Data File sequence.
1

For User defined choice of nominating which side of an FFW is to


carry any Allowance.
(Once this option is selected the choice will have to be made at
all FFW's in the Pipe).

Switch Layout

Version

Related Program Development Specs.

Date

First
Introduced
Extended
Use

Details

OPT - 128

Switches
by number
Switches
by name

- 184 -

ALIAS

129. Interactive editing

Options

ISOGEN
Switch Title

Option Switch No.

129

INTERACTIVE EDITING
Description

This Option Switch activates the use of the Interactive Editing function
within the SPOOLGEN system which is used to add supplementary
information to Pipeline Input Data Files.
Note. This option only operates on PC versions of ISOGEN running under
the control of the SPOOLGEN system.

Switch Settings

Default for the Interactive Editing System not to be activated.

To run the Interactive Editing System.

Switch Layout

Switch
Position

Either
Setting
Version

Related Program Development Specs.


First
Introduced

SPOOL DEFINITION SYSTEM.

7.1

Date

JUN 94

Details

Extended
Use

OPT - 129

Switches
by number
Switches
by name

- 185 -

ALIAS

130. Development testing

Options

ISOGEN
Switch Title

Option Switch No.

130

DEVELOPMENT TESTING
Description

This Option Switch is a special one that is reserved for use only by the
ISOGEN Administration Team for development and testing purposes.
Users must leave the setting at the default value of zero (0).

Switch Settings

Switch Layout

Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 130

Switches
by number
Switches
by name

- 186 -

ALIAS

131. Development testing

Options

ISOGEN
Switch Title

Option Switch No.

131

DEVELOPMENT TESTING
Description

This Option Switch is a special one that is reserved for use only by the
ISOGEN Administration Team for development and testing purposes.
Users must leave the setting at the default value of zero (0).

Switch Settings

Switch Layout

Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 131

Switches
by number
Switches
by name

- 187 -

ALIAS

132. Development testing

Options

ISOGEN
Switch Title

Option Switch No.

132

DEVELOPMENT TESTING
Description

This Option Switch is a special one that is reserved for use only by the
ISOGEN Administration Team for development and testing purposes.
Users must leave the setting at the default value of zero (0).

Switch Settings

Switch Layout

Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 132

Switches
by number
Switches
by name

- 188 -

ALIAS

133. Development testing

Options

ISOGEN
Switch Title

Option Switch No.

133

DEVELOPMENT TESTING
Description

This Option Switch is a special one that is reserved for use only by the
ISOGEN Administration Team for development and testing purposes.
Users must leave the setting at the default value of zero (0).

Switch Settings

Switch Layout

Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 133

Switches
by number
Switches
by name

- 189 -

ALIAS

134. Development testing

Options

ISOGEN
Switch Title

Option Switch No.

134

DEVELOPMENT TESTING
Description

This Option Switch is a special one that is reserved for use only by the
ISOGEN Administration Team for development and testing purposes.
Users must leave the setting at the default value of zero (0).

Switch Settings

Switch Layout

Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 134

Switches
by number
Switches
by name

- 190 -

ALIAS

135. Development testing

Options

ISOGEN
Switch Title

Option Switch No.

135

DEVELOPMENT TESTING
Description

This Option Switch is a special one that is reserved for use only by the
ISOGEN Administration Team for development and testing purposes.
Users must leave the setting at the default value of zero (0).

Switch Settings

Switch Layout

Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 135

Switches
by number
Switches
by name

- 191 -

ALIAS

136. Development testing

Options

ISOGEN
Switch Title

Option Switch No.

136

DEVELOPMENT TESTING
Description

This Option Switch is a special one that is reserved for use only by the
ISOGEN Administration Team for development and testing purposes.
Users must leave the setting at the default value of zero (0).

Switch Settings

Switch Layout

Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 136
Switches
by number
Switches
by name

- 192 -

ALIAS

137. Development testing

Options

ISOGEN
Switch Title

Option Switch No.

137

DEVELOPMENT TESTING
Description

This Option Switch is a special one that is reserved for use only by the
ISOGEN Administration Team for development and testing purposes.
Users must leave the setting at the default value of zero (0).

Switch Settings

Switch Layout

Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 137

Switches
by number
Switches
by name

- 193 -

ALIAS

138. Plotfile - DGN link and ASCII text

Options

ISOGEN
Switch Title

Option Switch No.

PLOTFILE - DGN LINK


PLOTFILE - ASCII TEXT

138

Description

This Option Switch controls two functions related to the generation of DGN
format isometric output files.
On platforms that support the generation of DGN files, this Option Switch
controls the creation of a link file between the ISOGEN system and the
DGN software.
An additional option allows the User to select ASCII Text characters (as an
alternative to Vector text) for use within the DGN file.
Switch Settings

This Option Switch is in three parts.


SWITCH POSITIONS 1, 2 & 3 - Currently Unused.
0
Must always be set to zero.
SWITCH POSITION 4 - Generation of ASCII characters in DGN file.
0 or blank For default of Vector Text characters.
1
For generation of ASCII characters.
SWITCH POSITION 5 - Generation of DGN format output files.
0 or blank For generation of normal plotfiles as nominated in Option
Switch 71.
1
For generation of DGN format output files.
Option Switch 71 must be set to a value of 6.

Switch Layout

Blank or
Zero
one
Blank or one

Switch
Position

Zero
Version

Related Program Development Specs.


First
Introduced
Related Option Switches.

6.0

Date

MAR 91

Extended
Use

O.S.
7171

OPT - 138

Switches
by number
Switches
by name

- 194 -

ALIAS

139. Development testing

Options

ISOGEN
Switch Title

Option Switch No.

139

DEVELOPMENT TESTING
Description

This Option Switch is a special one that is reserved for use only by the
ISOGEN Administration Team for development and testing purposes.
Users must leave the setting at the default value of zero (0).

Switch Settings

Switch Layout

Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 139

Switches
by number
Switches
by name

- 195 -

ALIAS

140. Development testing

Options

ISOGEN
Switch Title

Option Switch No.

140

DEVELOPMENT TESTING
Description

This Option Switch is a special one that is reserved for use only by the
ISOGEN Administration Team for development and testing purposes.
Users must leave the setting at the default value of zero (0).

Switch Settings

Switch Layout

Version

Related Program Development Specs.


First
Introduced

NONE

1.0

Date

APR 83

Extended
Use

OPT - 140

Switches
by number
Switches
by name

- 196 -

ALIAS

Plotfile length

O.S. 1

PLOTFILE LENGTH

Maximum Plotfile Length


e.g. 3275 mm

This Option Switch only operates on plotters that use a plot roll rather
than single sheets - and where OS 31 = 0 to obtain multiple isometrics in
each plotfile like that shown above.
(It is not effective if OS 31=1 - when each plotfile will contain only a single
isometric - and hence is not used when single DXF or DGN plotfiles are
produced for importing into a 2D graphics system like AutoCAD or
MicroStation - when the isometrics are usually sent to a laser printer for
plotting).
Note. Some older plotters (like Benson Electrostatic) used to have a
maximum plotfile length of 3275 mm which is the default value.
Other similar plotters use a different maximum length value.
Under these settings the program considers the physical drawing size
and stacking arrangement - and will output the maximum number of
isometrics it can into each plotfile produced.
For example, if 20 isometrics were produced, you could get 3 plotfiles two with 8 isometrics each in them - and one with 4 isometrics.

ALIAS

Return to
front sheet

- 197 -

ALIAS

Cut piece numbering / list type

CUT PIECE NUMBERING / LIST TYPE

<4

O.S. 2

>

<1

>

<3>

<2>

This example shows


Numeric Identifiers

This is the New Style Cut Piece List


(OS 2 Pos. 2 = 1)
- the Old Style is no longer
recommended.

Cut Piece identifiers are enclosed in brackets like this <1>


The identifiers may be :Number based - like this
or Alpha based -

<1> (OS 2 Pos. 3 = 0).


<A> (OS 2 Pos. 3 = 1).

ALIAS

Return to
front sheet

- 198 -

ALIAS

Drawing trim marks

O.S. 3

Drawing Height

DRAWING TRIM MARKS


N

Drawing Width

Drawing Trim
Marks

Like OS1 - the facility provided by this Option Switch is really


only beneficial on plotters that use a plot roll rather than single
sheets.
Drawing Trim Marks are plotted at the extremities of each
isometric drawing - the distance away from the frame being the
margin settings.
Trimming to the marks provides the exact drawing size.

ALIAS

Return to
front sheet

- 199 -

ALIAS

Drawing text size

DRAWING TEXT SIZE

O.S. 4

Controls the text size for all generated characters


in this region of the isometric.
SMALL CHARACTERS - 2.1 MM

MEDIUM CHARACTERS - 2.4 MM

LARGE CHARACTERS - 2.8 MM

EXTRA LARGE CHARACTERS - 3.5 MM

EXTRA LARGE CHARACTERS - 4.2MM

EXTRA LARGE CHARACTERS - 4.9MM

ALIAS

Return to
front sheet

- 200 -

ALIAS

Co-ordinates: Connection/connectivity

CO-ORDINATES - CONNECTION/ CONNECTIVITY

POS 1 = 0

POS 1 =1

POS 2 = 0

POS 2 = 1

This text is on
ATEXT -240

POS 3 = 0

O.S. 5

This text is on
ATEXT -240

POS 3 = 1

1 OF 3

ALIAS

Return to
front sheet

- 201 -

ALIAS

CO-ORDINATES - CONNECTION/ CONNECTIVITY


Text is on
ATEXT -241

O.S 5

Text is on
ATEXT -241

POS 4 = 0

POS4 =1

POS 5 = 0

POS 5 = 1

POS 6 = 0

POS 6 = 1

2 OF 3

ALIAS

Return to
front sheet

- 202 -

ALIAS

CO-ORDINATES - CONNECTION/ CONNECTIVITY

O.S. 5

Text is on
ATEXT -242
Text is on
ATEXT -242

POS 7 = 0

POS 7 =1

Text comes
from the -47
record

Text comes
from the -47
record

POS 8 = 0

POS 8 =1
3 OF 3

ALIAS

Return to
front sheet

- 203 -

ALIAS

Date output

O.S. 6

DATE OUTPUT

Date formats
British 28 MAR 96
European28/03/96
American03/28/96
No Date output on Iso

British 21 APR 96
European21/04/96
American04/21/96

- OS 6 = 0
- OS 6 = 1
- OS 6 = 2
- OS 6 = 3

- OS 6 =10
- OS 6 = 11
- OS 6 = 12

The word DATE is in ATEXT -250

Month names are in ATEXT's -258 to -269

..........................
28/03/96........
..........................
..........................
..........................
..........................
..........................
..........................
..........................
..........................

These
settings use
the
Date entry in
the
Piping Data
File
(IDF or PCF)

These
settings get
the Date
entry from
your
computer on
the day of
processing

Use the ISOGEN -14 record to position the Date with TEXTPOS
(Text Positioning).

ALIAS

Return to
front sheet

- 204 -

ALIAS

Pipeline splitting: User control

PIPELINE SPLITTING - USER CONTROL

O.S. 7

Set OS 7 = 0 for automatic


drawing splitting
(this is the normal setting)

N
N

- the amount of information on


each DRG is controlled
by the program but may be
increased or decreased by use
of OS 38

3/3
2/3
1/3

Alternatively - to override
N
automatic splitting - set the
Switch value to required number
of DRG's
e.g. For 2 DRG's set OS 7 = 2

2/2
1/2

Warning ! A dictated number of DRG's would only be set for a


single nominated pipeline - on completion of which the value should
be reset to 0

ALIAS

Return to
front sheet

- 205 -

ALIAS

Dimension line standout

DIMENSION LINE STANDOUT

O.S. 8

Layer 2
STRING /
COMPOSITE
Layer 1
MESSAGES / SUPPORTS

Layer 3
OVERALL

Dimension Standout Distance varies


with the character text size Small text OS 4 = 1
Layer 1 - 6 mm
Layer 2 - 12 mm
Layer 3 - 18 mm

Medium text OS 4 =0
Layer 1 - 7 mm
Layer 2 - 14 mm
Layer 3 - 21 mm

Large text OS 4 = 2
Layer 1 - 8 mm
Layer 2 - 16 mm
Layer 3 - 24 mm

Extra Large text OS 4 = 3


Layer 1 - 9 mm
Layer 2 - 18 mm
Layer 3 - 27 mm

Extra Large text OS 4 =4


Layer 1 - 10 mm
Layer 2 - 20 mm
Layer 3 - 30 mm

Extra Large text OS 4 = 5


Layer 1 - 11 mm
Layer 2 - 22 mm
Layer 3 - 33 mm

ALIAS

Return to
front sheet

- 206 -

ALIAS

Dimension form

DIMENSION FORM

O.S. 9

String Dimensions
OS 9 Pos. 1 = 0

Composite Dimensions
OS 9 Pos. 1 = 3

1 of 3

ALIAS

Return to
front sheet

- 207 -

ALIAS

DIMENSION FORM

O.S. 9

String, Support / Message &


Reference Dimensions all ON
OS 9 Pos. 1 = 0
Reference
Dimension

Message
Dimension

String & Support / Message


Dimensions Suppressed.
Only Reference Dimensions ON
OS 9 Pos. 1 = 1

String Dimensions Suppressed.


Support / Message & Reference
Dimensions ON
OS 9 Pos. 1 = 2

2 of 3

ALIAS

Return to
front sheet

- 208 -

ALIAS

DIMENSION FORM

O.S. 9

Full String Dimensions


OS 9 Pos. 1 = 4

Gasket Dimensioning.
(Gaskets here are 2 mm thick)

OS 9 Pos. 2 = 0
(Gasket thickness
not included)

OS 9 Pos. 2 =1
(Gasket thickness
is included)

American style Dimensions.


(Dimension on top of line).
OS 9 Pos. 3 = 1

3 of 3

ALIAS

Return to
front sheet

- 209 -

ALIAS

Drawing margins

O.S. 10, 11, 12, 13

DRAWING MARGINS
Top
OS 12

Drawing Frame

Right

Left
OS 10

OS 11

Bottom
OS 13

Note.
These Margins must be set when using either : The standard ISOGEN Drawing Frame

Paper Size
e.g. A2 , ANSI 'C size, etc.

or

A User Defined Drawing Frame

Also - a large side margin (left or right) must be set to suit the width of a
Style 3 or 4 BOM.

ALIAS

Return to
front sheet

- 210 -

ALIAS

Drawing size: Postscript plotter size

DRAWING SIZE - STANDARD


& POSTSCRIPT PLOTTER SIZE

O.S. 14

Standard Paper Size


e.g. A2, ANSI 'C' size, etc.

This OS sets standard Drawing sizes - All the European 'A' series
paper sizes or the American ANSI sizes ('A' to 'E').
(For non-standard Drawing sizes - use OS 15 & 16).
Switch Positions 3 & 4 permits 'direct' PostScript files to be plotted at a
reduced scale.
N

Apparent size to ISOGEN - A2

Actual plotted size - A3

Note. This effect can also be achieved by plotting out of a


2D
graphics system - like AutoCAD or MicroStation.

ALIAS

Return to
front sheet

- 211 -

ALIAS

Drawing size: Height and width

DRAWING SIZE - HEIGHT & WIDTH

O.S. 15, 16

Height

Width

This OS sets non-standard Drawing sizes .


e.g. For a Drawing 300 mm High X 400 mm Wide
Set OS 15 = 300 & OS 16 = 400
(For standard Drawing sizes - use OS 14).

Notes.
Any settings in these two Option Switches causes any setting in OS
14 Pos. 1 & 2 to be ignored.
However, any setting in OS 14 Pos. 3 & 4 will not be ignored. This
means 'direct' PostScript files of a non-standard Drawing size may
produced at a reduced scale - in the same way that standard
Drawings can be.

ALIAS

Return to
front sheet

- 212 -

ALIAS

Flow Arrows: On components

FLOW ARROWS - ON COMPONENTS

O.S. 17

The arrow direction (and hence fluid flow or gas flow direction)
is controlled from the 3D Design System.
When called for by setting OS 17 = 0 - most normal in-line components
will have this Flow Arrow plotted alongside.
Note that there is an alternative type of Flow Arrow to this one.
See OS 112 for details of a Flow Arrow that is plotted directly on the
Pipe.
It is normal to use only one of the available Flow Arrows.
Most Users now prefer the one controlled from OS 112.

ALIAS

Return to
front sheet

- 213 -

ALIAS

Drawing frame: Program standard

DRAWING FRAME - PROGRAM STANDARD

O.S. 18

This OS allows you to switch the standard ISOGEN Drawing Frame ON or


OFF.
N

Drawing Frame
ON
OS 18 = 0
This is the default
4-AR-4000

Drawing Frame OFF


OS 18 = 1

4-AR-4000

The standard Drawing Frame is always switched OFF when


you are employing a User Defined Backing Frame.
For full details of the techniques used in making User Defined Backing
Frames - see the Training Slide that covers all aspects of that facility.

ALIAS

Return to
front sheet

- 214 -

ALIAS

Sloping pipeline indication method

SLOPING PIPELINE INDICATION METHOD

O.S. 19

This is how Falling Pipelines are indicated.


The default setting of value zero shows the Falls angle in
Degrees like that above.
Values of 1 to 5 show the Fall expressed in alternative ways.
A Value of 6 suppresses the Fall indication altogether
- like this

ALIAS

Return to
front sheet

- 215 -

ALIAS

Sloping pipeline indication limit

SLOPING PIPELINE INDICATION LIMIT

O.S. 20

This Option Switch works in conjunction with OS 19.


It sets the cut-off value that determines what steepness of
slope should be shown as a Fall - and what should not.
Referring to the example on slide OS 19 - if the cut-off value for that
pipeline was set to 4 (it was set to 6) then the slope would be shown
like this.

This is because the actual slope is now steeper than the cut-off value.

ALIAS

Return to
front sheet

- 216 -

ALIAS

Isometric type

ISOMETRIC TYPE

O.S. 21

OS 21 = 0
Combined isometric - A Full size iso containing Erector and
Fabricator information
Fab materials

Erection materials

1 OF 7

ALIAS

Return to
front sheet

- 217 -

ALIAS

O.S. 21

ISOMETRIC TYPE

OS 21 = 1
Erection / Offshore isometric - A Full size iso containing only
Erector Information
Erection or Offshore materials only

2 OF 7

ALIAS

Return to
front sheet

- 218 -

ALIAS

O.S. 21

ISOMETRIC TYPE

OS 21 = 2
Fabrication isometric - A Full size iso containing only Fabrication
Information
Fab materials only

3 OF 7

ALIAS

Return to
front sheet

- 219 -

ALIAS

O.S. 21

ISOMETRIC TYPE

OS 21 = 6
Spool isometric - Smaller size isos containing only single pipe
spools - with 'as-built' orientation

4 OF 7

ALIAS

Return to
front sheet

- 220 -

ALIAS

O.S. 21

ISOMETRIC TYPE

OS 21 = 4
Spool isometric - Smaller size isos containing only single pipe spools with 'flat' orientation

5 OF 7

ALIAS

Return to
front sheet

- 221 -

ALIAS

O.S. 21

ISOMETRIC TYPE

OS 21 = 10
A special type of isometric which has no pipeline graphics.

The drawing region is left blank for the pipeline isometric to be


added - either manually or with a 2D draughting system.
6 OF 7

ALIAS

Return to
front sheet

- 222 -

ALIAS

O.S. 21

ISOMETRIC TYPE

OS 21 =100
A special Test isometric. This example is Combined isometric

On a test isometric all numeric


values are substituted with a string
of XXXX characters like this

7 OF 7

ALIAS

Return to
front sheet

- 223 -

ALIAS

Cut piece add-on allowances

CUT PIECE ADD-ON ALLOWANCES


Actual
position

O.S. 22

Nominal position of Loose flange

Added on length of cut


pipe (e.g. 175 mm) - to
allow for adjustment of
pipe on site before
welding on flange

Normal cut length


Increased cut length

1) Loose Flange

Actual
position

Nozzle

Nominal Position
of
Field Fit Weld

Normal cut length


Increased cut length

2) FFW

Normal cut length


Increased cut length

3) Shop Test Weld

ALIAS

Return to
front sheet

- 224 -

ALIAS

Material list: Controls and file type

MATERIAL LIST - CONTROLS & M/C FILE TYPE O.S. 23

OS 23 = 100 - Style 1 Material List


This is the Standard BOM - it has fixed content and layout
It does not require an MLD control file

1 of 9

ALIAS

Return to
front sheet

- 225 -

ALIAS

MATERIAL LIST - CONTROLS & M/C FILE TYPE O.S. 23

'U' Pre-fixes
on Bends

Separate
material
entries

'B' Pre-fix on
field welds

OS 23 = 110 - Special Type Material List


Used by Siemens - is a variation on Style 1
Does not require an MLD control file
2 of 9

ALIAS

Return to
front sheet

- 226 -

ALIAS

MATERIAL LIST - CONTROLS & M/C FILE TYPE

O.S. 23

OS 23 = 200 - Style 2 Material List


Has the overall appearance of a Style 1 but this of Style of
BOM has User defined content and layout
Requires an MLD control file
3 of 9

Return to
front sheet

- 227 -

ALIAS

MATERIAL LIST - CONTROLS & M/C FILE TYPE

O.S. 23

23

OS 23 = 220 - Style 2 Material List


Same as the previous example except here, Alphabetic pointers are
used
Requires an MLD control file
4 of 9

Return to
front sheet

- 228 -

ALIAS

MATERIAL LIST - CONTROLS & M/C FILE TYPE

O.S. 23

ALIAS

OS 23 = 300 - Style 3 Material List


Uses a completely different concept to Style 1 or 2 - this type is
plotted onto a User defined backing sheet where each BOM entry is
positioned at a specific X-Y co-ordinate position
Requires an MLD control file containing basic X-Y co-ordinate
details
For further information - see the Material List slides
5 of 9

Return to
front sheet

- 229 -

ALIAS

MATERIAL LIST - CONTROLS & M/C FILE TYPE

O.S. 23

Spool Information

All materials except


Gaskets & Bolts have
unique suffix type ID
numbers e.g. this
ALIAS
elbow is part
number 6.4

OS 23 = 400 - Style 4 Material List


Same concept as Style 3 but this one also shows material usage for
each Spool
Like the Style 3 - requires an MLD control file containing basic X-Y
co-ordinate details

6 of 9

Return to
front sheet

- 230 -

ALIAS

MATERIAL LIST - CONTROLS & M/C FILE TYPE

O.S. 23

OS 23 = 10200 - Another type of Style 2 Material List


Here, there are no sub-headings and the BOM is partitioned into
groups
Requires an MLD control file

3 of 9
7
3

ALIAS

Return to
front sheet

- 231 -

ALIAS

O.S. 23

MATERIAL LIST - CONTROLS & M/C FILE TYPE

-6
-14
-8
-9
-10
-11
-12
-14
-17
-19
50
60
100
-20
100
-20
200
-20
200
-20
200
-20
300
-20
300
-20
400
-20
400
-20
500
-20
500
-20

6"-ASC-6900
02/08/96
1
P-5000
AR-102
CS-150
150#
01/03/96
PNT-23
200C
4
1
1
0
120
96 146
64
96
0
0 149
PAW-40
64
0
0
7
PAW-40
96
96
0
1
TAMF-6X6
96
64
0
2
RAM-E40FF-6X4
96
0
0
3
EAM-90L40
96
0
0
1
FAM-150WN40
64
0
0
2
FAM-150WN40
96
0
0
1
JFA-150R2
64
0
0
2
JFA-150R2
12
0
0
8
BAA-3/4X85
10
0
0
16
BAA-5/8X75

0
8
1

0
0
0

0
0
0

0
0
0

0
0
0

0
0
0

0
0
0

0
0
0

0
0
1

85

10

75

11

OS 23 Position 4 = 0 - Showing Standard Material Control File


output
This can be loaded into the Users Material Control System
This is the old original type containing fixed, non-User defined
information
8 of 9

ALIAS

Return to
front sheet

- 232 -

ALIAS

MATERIAL LIST - CONTROLS & M/C FILE TYPE

PIPELINE
REF
-------6"-ASC-6900
6"-ASC-6900
6"-ASC-6900
6"-ASC-6900
6"-ASC-6900
6"-ASC-6900
6"-ASC-6900
6"-ASC-6900
6"-ASC-6900
6"-ASC-6900
6"-ASC-6900

DRG
NO
--1
1
1
1
1
1
1
1
1
1
1

ITEM
CODE
---PAW-40
PAW-40
TAMF-6X6
RAM-E40FF-6X4
EAM-90L40
FAM-150WN40
FAM-150WN40
JFA-150R2
JFA-150R2
BAA-3/4X85
BAA-5/8X75

MAIN
BORE
---6
4
6
6
6
6
4
6
4
3/4
5/8

SEC
BORE
---6
4
6
4
6
6
4
6
4
3/4
5/8

O.S. 23

QTY
--14.863 M
0.674 M
1
2
3
1
2
1
2
8
16

OS 23 Position 4 = 1 - Showing User Defined Material Control


File output
This type permits variable content and layout
It requires an MLD File
This can also be loaded into the Users Material Control System

9 of 9

ALIAS

Return to
front sheet

- 233 -

ALIAS

Material list: Pipeline/drawing

MATERIAL LIST - PIPELINE / DRAWING

O.S. 24

OS 24 Position 1 controls whether Material Lists are produced by : Drawing


- OS 24 Pos 1 = 0
Pipeline - OS 24 Pos 1 = 1
Drawing (spool iso material part numbers will match full iso
material part numbers) - OS 24 Pos 1 = 2
Pipeline (spool iso material list numbers will match full iso
material list numbers) - OS 24 Pos 1 = 3
However, this is only relevant on Split isos having more than 1 drawing
Case 1)

OS 24 Pos 1 = 0 - Material List by Drawing


OS 24 Pos 1 = 3 - Material list by Drawing (appears in this
form on both full and spool isos, all part numbers match)
These are individual Drawing totals

DRG 1/2

DRG 2/2

1 OF 3

Return to
front sheet

- 234 -

ALIAS

MATERIAL LIST - PIPELINE / DRAWING

Case 2)

O.S. 24

OS 24 Pos 1 = 1 - Material List by Pipeline


OS 24 Pos 1 = 3 - Material list by Pipeline (appears in this
form on both full and spool isos, all part numbers match)

These are
grouped up totals
- for the complete
pipeline

DRG 1/2

DRG 2/2
(BOM area is blank)

2 OF 3

Return to
front sheet

- 235 -

ALIAS

MATERIAL LIST - PIPELINE / DRAWING

O.S. 24

OS 24 Position 2 controls the way Pipe Lengths are reported on


the BOM
There are 3 styles each for Metric and Imperial lengths

Metric - OS 24 Pos 2 = Blank

Imperial - OS 24 Pos 2 = Blank

Metric - OS 24 Pos 2 = 1

Imperial - OS 24 Pos 2 = 1

ALIAS

Metric - OS 24 Pos 2 = 2

Imperial - OS 24 Pos 2 = 2
3 OF 3

Return to
front sheet

- 236 -

ALIAS

Material list position

MATERIAL LIST - POSITION

O.S. 25

OS 25 Position 1 controls the location of where the BOM is plotted


- on the Left Hand or Right Hand side of the isometric
This only affects Styles 1 & 2 Material Lists, not Style 3 & 4

OS 25 Pos 1 = 0
BOM on LH side

OS 25 Pos 1 = 1
BOM on RH side

1 of 4

Return to
front sheet

- 237 -

ALIAS

O.S. 25

TITLE BLOCK - POSITION


OS 25 Position 2 controls where the Title Block is printed
relative to the BOM
It may be : In the default position at the bottom RH corner
Printed at the bottom of the BOM
Suppressed completely

OS 25 Position 2 = blank
Title Block in default position

2 of 4

Return to
front sheet

- 238 -

ALIAS

O.S. 25

TITLE BLOCK - POSITION

ALIAS

OS 25 Position 2 = 1
Title Block at bottom of BOM

3 of 4

Return to
front sheet

- 239 -

ALIAS

TITLE BLOCK - POSITION

O.S. 25

OS 25 Position 2 = 2
Title Block suppressed

4 of 4

Return to
front sheet

- 240 -

ALIAS

Material list: Descriptions

O.S. 26

MATERIAL LIST - DESCRIPTIONS

Switch Position 1 to suppress Item Descriptions only applies to


Style 1 BOM as this function is controlled from the MLD for all other
Styles (2, 3 and 4)

Example 1 - Style 1 BOM with OS 26 = 0


No Descriptions

ALIAS

No Blank Lines
between entries

Example 2 - Style 1 BOM with OS 26 = 11

Return to
front sheet

- 241 -

ALIAS

Material list: Text size

MATERIAL LIST - TEXT SIZE

O.S. 27

Controls the text size for all generated characters


in this region of the isometric.
ALIAS

SMALL CHARACTERS - 2.1 MM

MEDIUM CHARACTERS - 2.4 MM

LARGE CHARACTERS - 2.8 MM

EXTRA LARGE CHARACTERS - 3.5 MM

EXTRA LARGE CHARACTERS - 4.2MM

EXTRA LARGE CHARACTERS - 4.9MM

Return to
front sheet

- 242 -

ALIAS

Material list: Item code length

MATERIAL LIST - ITEM CODE LENGTH

O.S. 28

The longest Item Code on this the project for this example is
13 characters. Hence, OS 26 should be set to 13.
ALIAS

Return to
front sheet

- 243 -

ALIAS

Material list: Line spacing

MATERIAL LIST - LINE SPACING

O.S. 29

The BOM listing can be made to look shorter


or longer by changing the Line Spacing

100%

90%

Full length BOM list


OS 29 = 0 or 100

Shorter BOM list


OS 29 = 90

ALIAS

Return to
front sheet

- 244 -

ALIAS

Material list: Continuation method

MATERIAL LIST - CONTINUATION METHOD

O.S. 30

BOM Overflow
onto second
Material List area

LSS250

Case 1 - OS 30 = 0

LSS250

1/2

LSS250

2/2

N
ALIAS

BOM overflow
onto Dummy
'2 OF 2' sheet

Case 2 - OS 30 = 1

1 OF 2

Return to
front sheet

- 245 -

ALIAS

MATERIAL LIST - CONTINUATION METHOD

O.S. 30

LSS250

1/1

BOM overflow
onto Dummy '1A' sheet

Case 3 - OS 30 = 2
LSS250

1A

Case 4 - OS 30 = 10
ALIAS

Single sheet
isometric called 1/1

MSS150

1/1

2 OF 2

Return to
front sheet

- 246 -

ALIAS

Drawing output: File/screen

O.S. 31

DRAWING OUTPUT - FILE / SCREEN


OS 31 = 0
(and OS 1 =
3275)

Multiple isometrics all in one plotfile


(Most economic method when plotfiles
are going straight to a paper roll type plotter)
OS 31 = 1

Iso 1

Iso 2

Iso 3

Iso 4

Each isometric produced in a separate plotfile


(Used when plotfiles are DXF or DGN for loading
into a 2D graphics system or when plotfiles are
going straight to a laser printer)

OS 31 = 2
N

Isometrics sent to the screen (Does not work on PC)

ALIAS

Return to
front sheet

- 247 -

ALIAS

Drawing output: Scaling

O.S. 32

DRAWING OUTPUT - SCALING

N
OS 32 = 0
or 100 (Default)

CWS100
Full size isometrics

OS 32 = 71
(71% of nominated Drawing
size)

CWS100

Reduced size isometrics


Notes
1) With this Option Switch the whole of the isometric (frame and
inner contents) is re-scaled
2) If you are using a 2D graphics system such as AutoCAD and you
want to produce scaled down isometrics (e.g. effectively A2 size - but
scaled down to A3 on output) then that reduction should be done in the
graphics system, not with this Option Switch

ALIAS

Return to
front sheet

- 248 -

ALIAS

Drawing output: Picture scale

DRAWING OUTPUT - PICTURE SCALE

O.S. 34

N
OS 34 = 0
or 100 (Default)

CWS100
Normal picture scale

N
OS 34 = 150
(150% of nominated
Drawing size)

CWS100
Increased picture scale

Unlike OS 32 - this Option Switch only affects the picture part of the
isometric. Everything else remains the same size.

ALIAS

Return to
front sheet

- 249 -

ALIAS

Drawing: Reserved areas

DRAWING - RESERVED AREAS

Reserved Area distance


for Drawing Region

O.S. 35

Reserved Area distance


for Material List

Reserved Area is actually a distance setting which must always be in


mm's - even if you are an Imperial Units User

ALIAS

Return to
front sheet

- 250 -

ALIAS

Drawing output: Stacking value

DRAWING OUTPUT - STACKING VALUE

O.S. 36

Single stacking
OS 36 = 0 or 1

ALIAS

Double stacking
OS 36 = 2

Like OS 1 - this Option Switch only operates on plotters that use a plot
roll rather than single sheets - and where OS 31 = 0 to obtain multiple
isometrics in each plotfile like that shown above.

Return to
front sheet

- 251 -

ALIAS

Drawing output: Stacking orientation

DRAWING OUTPUT - STACKING ORIENTATION

O.S. 37

ALIAS

Along the plot roll


OS 37 = 0

Across the plot roll


OS 37 = 1

Again, this Option Switch only operates on plotters that use a plot roll
rather than single sheets - and where OS 31 = 0 to obtain multiple
isometrics in each plotfile like that shown above.

Return to
front sheet

- 252 -

ALIAS

Pipeline splitting: Automatic

PIPELINE SPLITTING - AUTOMATIC

O.S. 38

Example of Pipeline Splitting.


N

WS150 DRG 1/2


N

WS150 DRG 2/2

Here, OS 38 is set to the default value 0 (or 100).


The result is two drawings - each with approximately
the same amount of information
1 OF 2

Return to
front sheet

- 253 -

ALIAS

O.S. 38

PIPELINE SPLITTING - AUTOMATIC

WS150 DRG 1/1

By setting OS 38 to value 120 - more information will


be forced onto each drawing.
This results in only a single drawing being produced.
ALIAS

Note that care should be taken when specifying values > 100 . In
this respect the User takes full responsibility for the output results !

2 OF 2

Return to
front sheet

- 254 -

ALIAS

Spool piece identifiers

SPOOL PIECE IDENTIFIERS

O.S. 39

These are the two automatic Spool Piece Identifier types

OS 39 = 0
Numeric System

[D

[B

[A

[C]

OS 39 =2
Alphabetic System

1 OF 3

Return to
front sheet

- 255 -

ALIAS

SPOOL PIECE IDENTIFIERS

O.S. 39

This is how User Defined Spool Identifiers look :-

SPL A

NS
4"

14

These Identifiers may


either be entered in the
model by the 3D Designer
- or probed in using
SPOOLGEN

9
35

OS 39 = 0

ALIAS

2 OF 3

Return to
front sheet

- 256 -

ALIAS

O.S. 39

SPOOL PIECE IDENTIFIERS

These are alternative enclose types - controlled by OS 39 position 3

10

OS 39 Pos 3 = 1

SPL A

10

OS 39 Pos 3 = 2

SPL A

OS 39 Pos 3 = 3

OS 39 Pos 3 = 4

10

OS 39 Pos 3 = 5

SPL A

The are all obtainable with either Automatic or User Defined


Spool Identifiers
ALIAS

OS 39 position 4 controls how Spool Drawings are identified

SPL A

6"-ASC-6000 SPL A

OS 39 Pos 4 = 0

OS 39 Pos 4 = 1
5

3 OF 3

Return to
front sheet

- 257 -

ALIAS

Pipe supports

PIPE SUPPORTS

O.S. 40

OS 40 = 0
String Dimensions for Pipe Supports

ALIAS

OS 40 = 1
Overall Dimensions for Pipe Supports

1 OF 3

Return to
front sheet

- 258 -

ALIAS

PIPE SUPPORTS

O.S. 40

OS 40 = 2
Pipe Supports Suppressed

ALIAS

OS 40 = 3
Pipe Supports drawn but Un-dimensioned
2 OF 3

Return to
front sheet

- 259 -

ALIAS

PIPE SUPPORTS

O.S. 40

OS 40 = 10
Pipe Support Dimensions on Opposite Side

ALIAS

OS 40 = 2500
Pipe Support Standout Distance = 25 mm
(Which forces the Standout outside the normal dimension)

3 OF 3

Return to
front sheet

- 260 -

ALIAS

Bore/dimension/weight control

BORE / DIMENSION / WEIGHT CONTROL


E 44998
N 225000
EL +35000
4"N

O.S. 41

500

OS 41 = 0 - Mixed Units

E 147 ' 7.9/16"


N 738 ' 2.1/4"
EL +114 ' 9.5/16

1'
7

4"N

.11

/16

"

OS 41 = 1 - Imperial Units

ALIAS

E 44998
N 225000
EL +35000
10

500

0N

OS 41 = 2 - Metric Units

1 OF 4

Return to
front sheet

- 261 -

ALIAS

BORE / DIMENSION / WEIGHT CONTROL

E 44.998M
N 225.500M
EL +35.000M

4" N
S

500

O.S. 41

OS 41 Pos 2 = 1
Metric Co-Ordinates
output in M.mmm format

OS 41 Pos 3 - Feet & Inch output format - including Stacked


Fractions
See the Options & AText Manual for details - no further
example is needed here
ALIAS

Note that Stacked Fractions only apply to Imperial Dimensions


and currently, only operate on MicroStation DGN drawings
using a special font

2 OF 4

Return to
front sheet

- 262 -

ALIAS

BORE / DIMENSION / WEIGHT CONTROL

O.S. 41

OS 41 Pos 4 & 5 - Weight Information Output


OS 41 Pos 4 = 1
Weights output in KGS
format
OS 41 Pos 5 = 1
Component Weights are
listed as Total Weights

Total Component Weights

OS 41 Pos 4 = 1
Weights output in KGS
format
OS 41 Pos 5 = 2
Component Weights are
listed as Individual
Weights
ALIAS

Individual Component Weights

Note that this Option Switch is used to control the output of basic
component Weights. More extensive Weight functionality - including
Pipe Full, Weights of Insulation, and C of G calculations - are
controlled by OS 82
3 OF 4

Return to
front sheet

- 263 -

ALIAS

BORE / DIMENSION / WEIGHT CONTROL

O.S. 41

OS 41 Pos 6 & 7 - Imperial Dimensions Output Format

OS 41 Pos 6 & 7 = 0 or Blank

OS 41 Pos 6 & 7 = 12

OS 41 Pos 8 - Bore Suppression at Tees / Olets and Reducers

ALIAS

OS 41 Pos 8 = 0 or Blank
Bore information plotted

OS 41 Pos 8 = 1
Bore information not plotted
4 OF 4

Return to
front sheet

- 264 -

ALIAS

Drawing viewpoint

O.S. 42

DRAWING VIEWPOINT

OS 42 = 0 (or 3)

OS 42 = 7

ALIAS

OS 42 = 1

OS 42 = 5
1 OF 2

Return to
front sheet

- 265 -

ALIAS

DRAWING VIEWPOINT

O.S. 42

OS 42 = 2

OS 42 = 6

ALIAS

OS 42 = 4

OS 42 = 8
2 OF 2

Return to
front sheet

- 266 -

ALIAS

Pipe wastage factor: areas 1 to 9

PIPE WASTAGE FACTOR - AREAS 1 TO 9

O.S. 43-51

The Isogen Pipe Wastage facility permits you (optionally) to allow


extra tube material to be provided to allow for wastage during spool
fabrication.
When the facility is used, the Pipe length entries on the Material
List are increased by a User defined amount.
_______________________
There are two parts to the Pipe Wastage facility :_______________________
1) The Basic Pipe Wastage Allowance is set by the User in the
Piping Model on a Plant Area number basis. This value is
expressed in terms of a percentage Wastage Factor - e.g. 10% and is extracted and held at pipe component level in the Piping
Data File.
Note that this basic Pipe Wastage Allowance actually operates
independently of any settings in Option Switches 43 - 51.
E.G. For a nominal tube length entry of 1000 mm which has a 10%
Wastage Factor set in the Piping Model - the actual Material List
entry would be 1000 + 10% = 1100
Note that if the Pipe Wastage Allowance is set in the Piping Data
File to zero - then setting OS 43-51 will have no effect
(because 0 X any value = 0)
_______________________
ALIAS

2) Any such basic Pipe Wastage Factor set in the Piping Model
may then be (optionally) overridden and increased (Note. never
decreased) by the Isogen User through the use of Option Switches
43 to 51.
E.G. For the example given in 1) above, if the pipe there was in
Plant Area 2 and the Wastage Allowance needed to be increased
to 20% - then Option Switch 44 would be set to 2.
_______________________

Return to
front sheet

- 267 -

ALIAS

Equipment trim drawings

EQUIPMENT TRIM DRAWINGS

O.S. 52

Equipment Trim isometrics are special types of drawings where


Isogen produces a document having a BOM, an outline frame and
a large empty area.
In this example the materials connected to each nozzle are grouped
up and listed separately - as shown below - this type of listing is
produced by setting OS 52 Pos 1 = 0

ALIAS

The drawing part shown in green


is produced in a 2D drawing system
(like AutoCAD or MicroStation) and
is then superimposed onto the empty
area of the Isogen isometric to form a
complete picture

Return to
front sheet

- 268 -

ALIAS

Weld numbering

WELD NUMBERING

O.S. 53

OS 53 = 1
Small Size Weld Numbers

OS 53 = 2
Medium Size Weld Numbers
ALIAS

OS 53 = 3
Large Size Weld Numbers
1 OF 4

Return to
front sheet

- 269 -

ALIAS

WELD NUMBERING

O.S. 53

OS 53 = 6
Fab Welds only numbered - Medium Size

ALIAS

OS 53 = 8
Erection Welds only numbered - Medium Size
2 OF 4

Return to
front sheet

- 270 -

ALIAS

WELD NUMBERING

O.S. 53

This is a User Defined Weld Summary Box.


ALIAS

It is generated by setting OS 53 Pos 2 = 1 and calling in a Weld


Definition File (WDF).
(For details of the WDF see the separate Welding slides).
Note that there is another type of Weld Summary Box - one that
does not require a WDF. However that type is not User Defined - it
has a fixed content and layout. Although it is generated simply by
setting OS 53 Pos 2 = 1 - it is no longer in common use.

3 OF 4

Return to
front sheet

- 271 -

ALIAS

WELD NUMBERING

O.S. 53

For details of OS 53 Positions 3 & 4 - see the front sheets - no


further explanation is needed here.

OS 53 Pos 5 Controls Weld Numbering Sequence. For example, if


you want Fabrication Welds and Erection Welds to have their own
Weld Numbering Sequence - set OS 53 Pos 5 = 1

SH2

SH1

ER1
SH3

SH4

ER2

ER3

ALIAS

Example where Fabrication


and Erection Welds use the
same Weld Numbering
Sequence - OS 53 Pos 5 =
blank

Example where Fabrication


and Erection Welds use their own
Weld Numbering Sequence - OS 53
Pos 5 = 1
Note that in this case individual
enclosures and Weld Number
Prefixes are recommended - as
shown here.
4 OF 4

Return to
front sheet

- 272 -

ALIAS

Weld plotting

WELD PLOTTING

O.S. 54

OS 54 = 1 - All Welds suppressed.

OS 54 = 2 - Only Site Welds plotted


ALIAS

OS 54 = 3 - Only Fab Welds plotted


1 OF 2

Return to
front sheet

- 273 -

ALIAS

WELD PLOTTING

O.S. 54

OS 54 = 0

In this example all the materials are designated Erection - this causes
all the Welds to automatically become Erection Welds as shown here

OS 54 = 4

ALIAS

Changing to OS 54 = 4 causes all the Erection Welds to be changed


so they look like Fabrication Welds
(Note that in doing this - the type of weld numbers generated
are change also)
2 OF 2

Return to
front sheet

- 274 -

ALIAS

Program messages: Run information

PROGRAM MESSAGES - RUN INFORMATION

O.S. 55

OS 55 = 0
ISOGEN PC VERSION 7.7
THE FOLLOWING DRAWINGS ARE IN PLOTFILE D:\PSTDMIX\FULLISO\DXFOUT\FUL001.DXF
DRG. 1 /6"-ASC-6900
PLOTTED

OS 55 = 1
ISOGEN PC VERSION 7.7
**** ISODAT ****
START OF DRAWING 6"-ASC-6900
OUTPUT STAGE OF DRAWING 6"-ASC-6900
**** ISOPLOT ****
THE FOLLOWING DRAWINGS ARE IN PLOTFILE D:\PSTDMIX\FULLISO\DXFOUT\FUL002.DXF
DRG. 1 /6"-ASC-6900
PLOTTED

OS 55 = 2
ISOGEN PC VERSION 7.7
ALIAS
**** ISODAT
****
START OF DRAWING 6"-ASC-6900
OUTPUT STAGE OF DRAWING 6"-ASC-6900
**** ISOPLOT ****
DRG 1 SHAPED
DRG 1 SIMULATE
THE FOLLOWING DRAWINGS ARE IN PLOTFILE D:\PSTDMIX\FULLISO\DXFOUT\FUL003.DXF
DRG. 1 /6"-ASC-6900
PLOTTED

Return to
front sheet

- 275 -

ALIAS

Instrument identification

INSTRUMENT IDENTIFICATION

O.S. 59

OS 59 = 0 - Outputs the Instrument Name on the Material List.

OS 59 = 1 - Outputs the Instrument Item Code on the Material List.

ALIAS

OS 59 = 0 or 1

Note that this Option Switch only controls what parameter is output
on the Material List / Material Control File - the Instrument's Name or
the Instrument's Item Code. On the Drawing part - the Instrument's
Name is always output regardless of the Option Switch setting.

Return to
front sheet

- 276 -

ALIAS

Component tagging

O.S. 60

COMPONENT TAGGING

OS 60 = 0
No Component Tagging

OS 60 = 1
Component Tagging
On
and boxed in

ALIAS

OS 60 = 2
Component Tagging
On
but not boxed in

Return to
front sheet

- 277 -

ALIAS

Insulation indication

O.S. 61

INSULATION INDICATION

OS 61 = 0
Insulation Indication On alongside Pipe only

OS 61 = 1
Insulation Indication
Suppressed

ALIAS

OS 61 = 2
Insulation Indication On alongside Pipe &
Components

Return to
front sheet

- 278 -

ALIAS

Tracing indication

O.S. 62

TRACING INDICATION

OS 62 = 0
Tracing Indication On
alongside Pipe only

OS 62 = 2
Tracing Indication On alongside Pipe &
Components

ALIAS

OS 61 = 0 & OS 62 = 0
In this example - the Pipe is
both Traced and Insulated

Return to
front sheet

- 279 -

ALIAS

Printed output: Page length

O.S. 63

PRINTED OUTPUT - PAGE LENGTH


XXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXX

55
Lines

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

PAGE 1

PAGE 2

OS 63 = 0

XXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

66
Lines

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
ALIAS
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

PAGE 1

PAGE 2

OS 63 = 66

Return to
front sheet

- 280 -

ALIAS

Pipe support identification

PIPE SUPPORT IDENTIFICATION

O.S. 64

OS 64 = 0 - No Support Name on the isometric - Item Code


output on the Material List

OS 64 = 1 - Support Name on the isometric un-boxed Support Name output on the Material List
ALIAS

OS 64 = 2 - Support Name on the isometric boxed Item Code output on the Material List

Return to
front sheet

- 281 -

ALIAS

Bolting units

BOLTING UNITS

O.S. 65

Bolts on the Isometric Material List and in the Material Control file
may be reported in any combination of Diameter and Length Units.
E.G.

5/8" Dia X 4" Long


5/8" Dia X 100 mm Long
16 mm Dia X 100 mm Long
16 mm Dia X 4" Long

The purpose of this Option Switch to enable the Bolt Diameter and
Length values held in the Piping Data file to be correctly interpreted
by the Program.

This is because regardless of what Units are being employed - all


Bolt Diameter and Length values are held in the Piping data File as
integer type numbers Inch Units are held in 1/16" th's of an Inch
Millimetres are held directly in mm's
Hence -

5/8" Diameter is held as 10 (ten sixteenths)


4" Long is held as 64 (64 sixteenths)
16 mm. Diameter is held as 16
100 mm. Long is held as 100
ALIAS

From this it can be seen that if this Option Switch is not set to
correctly match the Bolt Unit values in the Piping Data file - the
Bolting information reported by the Program will be incorrect !

Return to
front sheet

- 282 -

ALIAS

Co-ordinates: Supplementary

CO-ORDINATES - SUPPLEMENTARY

O.S. 66

66

The Start End

This type of
end co-ordinate shown in red - is
controlled by O.S. 5
- not O.S. 66

The Supplementary
elevations controlled by
O.S. 66 Pos 1
are shown here in green

OS 66 = 0
This default setting causes only
elevations that change
ALIAS to a new level to be
output - on arrowed out message lines.
With this setting - even though N/S and E/W
co-ordinates may also change - they are not
output

This sketch shows the default co-ordinate information that is output


1 OF 5

Return to
front sheet

- 283 -

ALIAS

CO-ORDINATES - SUPPLEMENTARY

O.S. 66

ALIAS

OS 66 = 1
Causes all Supplementary co-ordinates and elevations to be
output along Witness Lines instead of on arrowed-out
messages

2 OF 5

Return to
front sheet

- 284 -

ALIAS

CO-ORDINATES - SUPPLEMENTARY

O.S 66

ALIAS

OS 66 = 221
Supplementary elevations and co-ordinates output at Bend, Elbow,
and Branch Intersection positions - in all those cases where the
elevation level or N/S or E/W co-ordinates have changed.

3 OF 5

Return to
front sheet

- 285 -

ALIAS

CO-ORDINATES - SUPPLEMENTARY

O.S. 66

ALIAS

OS 66 = 330 (or 331)


A Full set of all three co-ordinates are output

4 OF 5

Return to
front sheet

- 286 -

ALIAS

CO-ORDINATES - SUPPLEMENTARY

O.S. 66

Co-ordinates output at Isometric Split Points

1) OS 66 Pos 4 = Blank - Split Point co-ordinates not output

ALIAS

2) OS 66 Pos 4 = 1 - Split Point co-ordinates output


5 OF 5

Return to
front sheet

- 287 -

ALIAS

Sloping pipeline: 3D skew depiction

SLOPING PIPELINE - 3D SKEW DEPICTION -

O.S. 67

105

OS 67 = 0 - 3D Box depiction

ALIAS

OS 67 = 1 - 2D Triangle + Falls Indicator

Return to
front sheet

- 288 -

ALIAS

Sloping pipeline: Vertical branches

SLOPING PIPELINE - VERTICAL BRANCHES

O.S. 68

OS 68 = 0 - Default to show the Short Tee branch leg skewed

ALIAS

OS 68 = 1 - To show the Short Tee branch leg straight

Return to
front sheet

- 289 -

ALIAS

Terminal type identification

TERMINAL TYPE IDENTIFICATION

O.S. 69

This Option Switch is used if you want to see your isometrics directly
on the screen rather than sent to a file and then plotted.

Note. You cannot send isometrics directly to the screen if you are
using the PC Version of Isogen or Spoolgen ! With that version
all isometric output must first be output to a file.
ALIAS

Return to
front sheet

- 290 -

ALIAS

Skew identification: Branches

SKEW INDICATION - BRANCHES

O.S. 70

OS 70 = 0 - Normal Skew Box / Triangle depiction

ALIAS

OS 70 = Value - Skew Box / Triangle suppressed


(Here the value 4 was set)

Return to
front sheet

- 291 -

ALIAS

Material part number: Enclosure style

MATERIAL PART NUMBER - ENCLOSURE STYLE

O.S. 73

OS 73 = 0
Standard Part Number Box
- No special Blank Style Enclosure Box
5

STYLE 1 BLANK
ENCLOSURE BOXES

2
Note that the end
type of a Style 1
Blank box is
controlled by
OS 73 Pos 5

The Blank boxes


are for manually
added
information

OS 73 = 12
Square Ended Style 1 Blank Enclosure Box with
12 blank character spaces
1 OF 2

Return to
front sheet

- 292 -

ALIAS

MATERIAL PART NUMBER - ENCLOSURE STYLE

Note that the end


type of a Style 2
box is controlled by
Option Switch 76

O.S. 73

STYLE 2
ENCLOSURE BOXES

OS 73 = 1200 & OS 76 = 1
Diamond Ended Style 2 Enclosure Box with 12 blank
character spaces

The STYLE 3 ENCLOSURE BOX style is a special one - It


was introduced for one ISOGEN client only and it
incorporates
their particular requirements.
For this reason it is not shown here.
2 OF 2

Return to
front sheet

- 293 -

ALIAS

Material list: Accumulation control

MATERIAL LIST ACCUMULATION CONTROL

O.S. 74

OS 74 = 0
Default - whereby Fab
Erection & Offshore materials
are all accumulated normally

OS 74 = 3
Non-accumulation for Fab
materials - including Pipe

ALIAS

Note. Non-Accumulation means that each occurrence of an item


results in a quantity of 1 OFF being listed - and for Pipe each
individual length is listed separately
1 OF 2

Return to
front sheet

- 294 -

ALIAS

MATERIAL LIST ACCUMULATION CONTROL

O.S. 74

OS 74 = 13
Non-accumulation for Erect
materials - Note that with this
setting Gaskets and Bolts are
still accumulated normally

OS 74 = 11113
Non-accumulation for all Erect
materials - With this setting
Gaskets and Bolts are also
Non-accumulated.
(Note that the Bolts are in
sets)

ALIAS

2 OF 2

Return to
front sheet

- 295 -

ALIAS

Weld number: Enclosure and prefix

WELD NUMBER - ENCLOSURE


WELD NUMBER - PREFIX

O.S. 75

In this example : 2 different Weld Number Enclosure types are demonstrated


Fab and Erect Welds use their own Weld Numbering sequence
Weld Number Prefixes are not shown

Diamond Ended
enclosure for Fab
Welds

Round Ended enclosure


for Erect Welds
OS 75 = 2 0 1

1 OF 2

Return to
front sheet

- 296 -

ALIAS

WELD NUMBER - ENCLOSURE


WELD NUMBER - PREFIX

O.S. 75

This is the same as the previous example except that Weld Number
Prefixes are also shown here SH for Fab
ER for Erect
Erect Weld
Prefix ON

Fab Weld
Prefix ON

OS 75 = 1 2 1 1

OS 75 simply switches on the Weld Number Prefix facility - it does


not define the actual Prefix character(s)
ALIAS

In the ISOGEN / SPOOLGEN systems the Prefix characters are


defined using -130 -131 -132 and -133 records
In the IDFGEN system the Prefix characters are defined using the
following Pipe Header attributes:WELD-PREFIX-GENERAL
WELD-PREFIX-ERECTION

WELD-PREFIX-FABRICATION
WELD-PREFIX-OFFSHORE
2 OF 2

Return to
front sheet

- 297 -

ALIAS

Material part number enclosure shape

MATERIAL PART NUMBER ENCLOSURE SHAPE

Flange Gasket Bolt


enclosure

Standard
enclosure

Enclosure
End Shape

OS 76

F3 G5 B6

Rectangular

F3 G5 B6

Diamond

F3 G5 B6

Round

F3 G5 B6

No Enclosure

No Part Number
No Enclosure

O.S. 76

ALIAS

OS 76 = 0
Default Rectangular Ends
1 OF 3

Return to
front sheet

- 298 -

ALIAS

MATERIAL PART NUMBER ENCLOSURE SHAPE

O.S. 76

OS 76 = 1
Diamond Ends

ALIAS

OS 76 = 2
Round Ends
2 OF 3

Return to
front sheet

- 299 -

ALIAS

MATERIAL PART NUMBER ENCLOSURE SHAPE

O.S. 76

OS 76 = 7
No Enclosure Boxes

ALIAS

OS 76 = 8
No Part Numbers nor Enclosure Boxes
3 OF 3

Return to
front sheet

- 300 -

ALIAS

Weld number allocation at slip-on flanges and reinforcement pads

WELD NUMBER ALLOCATION AT SLIP-ON


FLANGES & REINFORCEMENT PADS

OS 77 = 0 or 2
For two Weld Numbers

O.S. 77

OS 77 = 1
For one Weld Number

OS 77 Pos 1 - Controls the quantity of Weld Numbers


generated at Slip-On Flanges

ALIAS

OS 77 Pos 2 = 0 or Blank
For No extra Weld Numbers

OS 77 Pos 2 - Controls the quantity of Weld Numbers


generated at Reinforcement Pads
1 OF 2

Return to
front sheet

- 301 -

ALIAS

WELD NUMBER ALLOCATION AT SLIP-ON


FLANGES & REINFORCEMENT PADS

O.S. 77

OS 77 = 1 1 1
For 1 extra Pad Weld Number and the generation of
a plotted Pad shape and Material List entry

OS 77 Pos 3 - Enables the automatic generation of a plotted shape for


the Reinforcement Pad together with an Item Code and Description
entry on the Material List

ALIAS

OS 77 = 1 2 1
For 2 extra Pad Weld Numbers

2 OF 2

Return to
front sheet

- 302 -

ALIAS

Dimensions: To valve centres

DIMENSIONS - TO VALVE CENTRES

O.S. 80

OS 80 = 0
Default for ordinary
Dimensioning - to the Valve
Ends

OS 80 = 1000
For Dimensioning to the Valve Centre
on Socket Weld Valves and Instruments
ALIAS

Notes.
1) This example is for a Socket Weld Valve. The Dimensioning
method for this is controlled by OS 80 Pos 4
2) Further control for this function - by bore - is in OS 81 Pos 1

Return to
front sheet

- 303 -

ALIAS

Dimensions: Branches

DIMENSIONS - BRANCHES

O.S. 81

Positions 1-3 of this Option Switch are not for Branches at all. This
part is actually an extension of OS 80 - whereby Dimensioning to
the Centres of Valve and Instruments may also be done by bore
range.
(OS 80 controls Dimensioning to the Centres of Valve and
Instruments by end type)

OS 81 Pos 1-3 = 24
(& OS 80 Pos 4 =1)
- Gives Dimensions to Valve / Instrument
Centreline for all bores up to and
including 1.1/2"

ALIAS

OS 81 Pos 1-3 = 24
(& OS 80 Pos 4 =1)
- Gives Dimensions to Valve
Ends for 2" bore

1 OF 2

Return to
front sheet

- 304 -

ALIAS

DIMENSIONS - BRANCHES

O.S. 81

Branch Dimensioning functions are controlled by Positions 4, 5 & 6


and by Positions 7 & 8

OS 81 Pos 4 - 6 = Blank
OS 81 Pos 7 & 8 = Blank
- Gives full Branch Dimensioning regardless of the Branch Bore and the
Number of components in the Branch

OS 81 = 48 000
- Suppresses Branch
Dimensioning on Branch Bores 3"
and less - regardless of the
number of components in the
Branch

ALIAS

OS 81 = 2 048 000
- Puts Branch Dimensioning back on
again - because the Branch has more
than 2 components

2 OF 2

Return to
front sheet

- 305 -

ALIAS

C of G/weight output

C of G / WEIGHT OUTPUT

O.S. 82

Option Switch 82 provides further Weight functionality to that in


OS 41 Pos 4 & 5 which is for basic Component Weights only
OS 82 adds controls for :
Full (Wet) Pipeline Weight

Weight Of Insulation

Centre of Gravity of Pipeline - Empty or Full - with or


without Insulation

OS 82 Pos 1 switches On the C of G / Weights facility - and


controls whether the output values are per Pipeline or per Drawing

OS 82 Pos 1 2 & 3 = 1 1 1 - For Weight outputs


Dry Weight (Pipeline Empty)
Wet Weight (Pipeline Full)
Insulation Weight
ALIAS

Notes
1) These Weights are per Drawing and are output in this style
on the Drawing Frame using the ISOGEN TextPos facility
2) The Pipe Empty Weight is derived solely from the Weight of
components
1 OF 2

Return to
front sheet

- 306 -

ALIAS

O.S. 82

C of G / WEIGHT OUTPUT

OS 82 Pos 4 & 5 = 2 3 - For Centre of Gravity Outputs


Dry (Empty) C of G and Dry (Empty) + Insulation C of G position
Wet (Full) Pipe + Insulation C of G position

ALIAS

2 OF 2

Return to
front sheet

- 307 -

ALIAS

DXF file units

DXF FILE UNITS

O.S. 92

1
Drawing
Underlay

2
Detail
Sketches

DETAIL -

DETAIL -

DETAIL -

Where used - the Drawing Underlay (1) and Detail Sketches (2)
must be consistent in respect of the Units they are constructed with.
The resultant Output Drawing (3) will be generated by ISOGEN in the
same Units.

SEE DETAIL A
DETAIL - A

3
Isometric
Output
Drawings

Return to
front sheet

- 308 -

ALIAS

Component leg length

COMPONENT LEG LENGTH

O.S. 95

OS 95 = 0
Default for Leg Length
of 9 mm

ALIAS

OS 95 = 12
Showing increased Leg
Lengths of 12 mm

Return to
front sheet

- 309 -

ALIAS

Skew depiction: Individual/overall

SKEW DEPICTION - INDIVIDUAL / OVERALL

O.S. 97

OS 97 = 0
Default for Single Overall Box / Triangle enclosure around the
Skew section (This example shows a Triangle)

ALIAS

OS 97 = 1
For individual Box / Triangle Skew enclosures around each Branch
section

Return to
front sheet

- 310 -

ALIAS

Skew depiction: Style

O.S. 99

SKEW DEPICTION - STYLE

OS 99 = 0
Default for Skew Box depiction with normal dimensioning style

OS 99 = 1
Skew Triangle depiction with normal dimensioning style
ALIAS

OS 99 = 3
Skew Triangle depiction with alternative dimensioning style
1 OF 2

Return to
front sheet

- 311 -

ALIAS

O.S. 99

SKEW DEPICTION - STYLE

3D Skew Sections - will normally follow the value in Pos 1


that are set for 2D skews - unless the value 1 is set in Pos 2

In this 3D Skew example OS 99 Pos 2 is not set (it is left blank)


- So the skew type follows what is set in Pos 1 - in this case value 3 which gives Triangle depiction with alternative dimensioning style as in the last example on the previous page

ALIAS

Changing OS 99 Pos 2 = 1 causes 3D skews to be shown in the


Box style - like this example here
2 OF 2

Return to
front sheet

- 312 -

ALIAS

Skew depiction: Dimension line standout

SKEW DEPICTION - DIMENSION LINE STANDOUT

O.S. 100

This Option Switch is used to move the Triangle Dimension further out

ALIAS

OS 100 = 0
Default for standard dimension
distance - plotted alongside the
triangle line

OS 100 = 120
Gives an increased
standout distance of 12 mm

Return to
front sheet

- 313 -

ALIAS

Skew depiction: Triangle hatching

SKEW DEPICTION - TRIANGLE HATCHING

O.S. 101

This Option Switch enables Skew Triangles to be optionally filled in


with Hatching Lines
The controls here allow you to :

Vary the distance between the Hatch Lines


Have Full or Partial Hatching - Partial Hatching is where only part
of the triangle area is Hatched
With Partial Hatching - vary the amount of the Hatching

OS 101 = 1
Default for Triangle Hatching On This gives Full Hatching with a
Hatch Line pitch of 1 mm

ALIAS

OS 101 = 40
This gives Full Hatching with an
increased Hatch Line pitch of 4
mm
1 OF 2

Return to
front sheet

- 314 -

ALIAS

SKEW DEPICTION - TRIANGLE HATCHING

O.S. 101

OS 101 = 3540
This gives Partial Hatching with an
Hatch Line pitch of 4 mm and a
maximum Hatch Line Length of 35
mm

When setting Pos 3 & 4 to define a


Hatch Line Cut-Off value like that above - this is the length
that is defined
- in the above example this is 35 mm
2 OF 2

Return to
front sheet

- 315 -

ALIAS

Skew depiction: matching clearance

SKEW DEPICTION - HATCHING CLEARANCE

O.S. 102

This Option Switch controls the size of the Clearance Gaps that
occur in and around Hatching There are three of these such gaps :

Local to the Pipeline


Local to In-Line Components
Around Dimensions and Text that appear in the Hatching
region

Local toComponents
Local to
Pipeline

Around
Dimensions
and Text

OS 102 = 0
Default Gaps at all three
positions

ALIAS

OS 102 = 404040
Gaps increased to 4 mm
at all three positions

Return to
front sheet

- 316 -

ALIAS

Pipeline splitting: In tube

O.S. 108

PIPELINE SPLITTING - IN TUBE

SITUATION

ISOGEN wants to split the


pipeline into 2 drawings in tube - at this point

DRAWING
1

DRAWING 2

ALIAS

This Option Switch controls what action the Program must


take when presented with the above situation
For the three possible actions - see the Options & Atext manual

Return to
front sheet

- 317 -

ALIAS

Repeatability file content

O.S. 109

REPEATABILITY FILE CONTENT

When it is required to pass ISOGEN generated information back to


your 3D Design System - then the REPEATABILITY (or RETURN)
File System is used
Not all 3D Systems can use it however !
Some don't have the capability
For details of what information may be passed back in this way - see
the list in the Options & AText Manual
Note. This Option Switch also contains a non-Repeatability function Position 6 controls the action of component Re-ordering in By-Passes
This Re-ordering function is done by default - OS 109 Pos 6 = 0 or
blank -

Explanation :- In a by-pass like this - to enable correct


spools to be generated - ISOGEN needs to have
the closure point at either of these two positions
However, the IDF
extraction program
of some 3D Design
systems sets the
closure point here

ALIAS

or here

By default - OS 109 Pos 6 = 0 or blank - which causes ISOGEN to


always set the by-pass closure point at the preferred position. If
this proves to give problems - you must unset this action by
setting Pos 6 = 1

Return to
front sheet

- 318 -

ALIAS

Ghost gaps

O.S. 110

GHOST GAPS

Ghost Gaps are created in the 3D Design System and are used to link
related, but unconnected components - for example :

One Pipeline to another - to form a System Isometric


One part of a Pipeline to another part of the same Pipeline where a middle section may have a 'hold' on it - thus remaining
incomplete and not finished

Note. Gaps may


be dimensioned or
un-dimensioned but this feature is
not controlled by
this Option Switch
- it is controlled
from within the 3D
Design System
whereby
appropriate
settings are made
in the extracted
Piping Data File

ALIAS

(This example
shows an undimensioned Gap)

OS 110 = 0
Gives the
standard size
Gap - like
this

These examples
shows part of a
System
isometric
- consisting of 2
Pipelines

OS 110 = 50
Increases
the Gap size
so it looks
like this

Return to
front sheet

- 319 -

ALIAS

Nozzles

O.S. 111

NOZZLES

OS 111 = 0
Default - Nozzles Not plotted

OS 111 = 1
Nozzles plotted
ALIAS

Return to
front sheet

- 320 -

ALIAS

Flow arrows: Pipeline

FLOW ARROWS - PIPELINE

OS 112 = 5

ALIAS

OS 112 = 0
or 8

O.S. 112

OS 112 = 15

Return to
front sheet

- 321 -

ALIAS

Spec break indication

O.S. 114

SPEC BREAK INDICATION

OS 114 = 0
Default for the old style single Spec
Break indication box

Note
Although it is shown here - this
style is now redundant and should
not
be used
As you can see - its not clear which
side of the division line the new spec
is referring to

OS 114 = 1
Two box indication

ALIAS

This is the recommend method this style is more informative - it


clearly indicates the spec for both
sides of the division line

Return to
front sheet

- 322 -

ALIAS

Tolerance: Offset angle

O.S. 115

TOLERANCE - OFFSET ANGLE

This Option Switch enables you to prevent the generation of


unwanted Skews. The Piping Data File extraction programs of some
3D Design Systems can contain small dimension inaccuracies leading to small movements at some pipe ends These small
movements are then detected by ISOGEN which then generates a
Skew section
3

Case 1 - OS 115 = 0

3 mm movement
in N/S plane - gives a
skew angle of 0.08

Case 2 - OS 115 = 25
This demonstrates that
setting a .25 degree cutoff value causes the
unwanted skew not to be
generated
ALIAS

Note
Option Switch OS 116 also controls unwanted skew generation - but
using a dimensional tolerance
However - either OS 115 or OS 116 must be set ! not both
Of the two Option Switches - OS 116 is the preferred one for you to
set - but OS 115 takes precedence if both are set

Return to
front sheet

- 323 -

ALIAS

Tolerance: Dimension offset

O.S. 116

TOLERANCE - DIMENSION OFFSET

Like OS 115 - this Option Switch also enables the prevention of


unwanted Skews - but by means of a Dimension Tolerance rather
than an Angle Tolerance

Case 1 - OS 116 = 0

1 mm movement
in N/S plane - causes a
skew to be generated

Case 2 - OS 116 = 250


This demonstrates that
setting a 2 mm cut-off
value causes the
unwanted skew not to be
generated
ALIAS

Note
Option Switch OS 115 also controls unwanted skew generation - but
using an angular tolerance
However - either OS 116 or OS 115 must be set ! not both
Of the two Option Switches - OS 116 is the preferred one for you to
set - but OS 115 takes precedence if both are set

Return to
front sheet

- 324 -

ALIAS

Dimensions: Overall

O.S. 118

DIMENSIONS - OVERALL

OS 118 = 1
Overall Dimensions On Going across Branches

OS 118 = 2
Overall Dimensions On Stopping at Branches

ALIAS

OS 118 = 3
Overall Dimensions On Going to Valve Centres
and going across Branches

1 OF 2

Return to
front sheet

- 325 -

ALIAS

O.S. 118

DIMENSIONS - OVERALL

OS 118 = 4
Overall Dimensions On Going to Valve Centres
but stopping at Branches

OS 118 = 344
The value 34 in
Pos 2 & 3
causes the
Standout distance
for the Overall
Dimensions to be
moved out from the
Note that doing this causes
standard
distance to 34 mm the standard dimension layer
to move to the inner position
ALIAS

OS 118 = 344 with


OS 8 = 16
This is to demonstrate that if you put a
value in OS 118 Pos 2 & 3 - you must
put a value in OS 8 to control the normal
dimension standout distance and keep it
in the standard position also

2 OF 2

Return to
front sheet

- 326 -

ALIAS

Dimensions/elevation: Vertical

DIMENSIONS / ELEVATION - VERTICAL

O.S. 119

OS 119 = 0
Default for Normal
Vertical pipe Dimensions &
Elevations plotted at intersection
points when the level changes

ALIAS

OS 119 = 1
All Vertical Dimensions
suppressed and replaced
by Elevation Messages
1 OF 2

Return to
front sheet

- 327 -

ALIAS

DIMENSIONS / ELEVATION - VERTICAL

O.S. 119

OS 119 = 2
For Vertical Dimensions
and Elevations output at
all normal dimensioning
positions

ALIAS

2 OF 2

Return to
front sheet

- 328 -

ALIAS

Tapping: Branch scale/branch dimensions/branch co-ordinates

TAPPING - BRANCH SCALE

O.S. 120

TAPPING - BRANCH DIMENSIONS

O.S. 121

TAPPING - BRANCH CO-ORDINATES

O.S. 122

OS 120 = 0 - Full size Branch


OS 121 = 0 - Branch Dimension On
OS 122 = 0 - No Tapping Point Co-ords

ALIAS

OS 120 = 60 - Reduced Branch Scaling


OS 121 = 1 - Branch Dimensions OFF
OS 122 = 1 - Tapping Point Co-ords plotted

Return to
front sheet

- 329 -

ALIAS

Instrument ID enclosure

INSTRUMENT ID ENCLOSURE

O.S. 123

OS 123 = 0
Default for No Balloon
around Instrument Name

OS 123 = 5
For the Instrument Name
to be plotted inside a 5
character size Balloon
ALIAS

OS 123 = 4
This Instrument Name has a $
character in it to make the name
be plotted over 2 lines here, it is inside a 4 character
size Balloon
1 OF 2

Return to
front sheet

- 330 -

ALIAS

INSTRUMENT ID ENCLOSURE

O.S. 123

OS 123 Pos 3 - Controls alternative Enclosure Box Shapes


1 gives

CV200

CV200

C1

C1

CV200

OS 123 = 100
For Diamond Ended Box
enclosure around
Instrument Name
ALIAS

Note that with these enclosure styles the Instrument Name must
be on one line - that is, the $ feature cannot be used in the name

2 OF 2

Return to
front sheet

- 331 -

ALIAS

Flange/rotation angles

FLANGE ROTATION ANGLES

O.S. 124

OS 124 = 0
Default for Flange
Rotation
Angles Not
indicated

OS 124 = 1
Flange Rotation
Angle indicated
ALIAS

Other Box Shapes


OS124 Pos 2
OS 124 = 11
Flange Rotation
Angle indicated - in a
Diamond Ended box

2 = FLANGE ROTATION 45.0


3 = FLANGE ROTATION 45.0

Return to
front sheet

- 332 -

ALIAS

Isogen version/run date

ISOGEN VERSION / RUN DATE

O.S. 127

OS 127 = 0
Default for Banner
Not to be plotted

OS 127 = 1
For Banner
to be plotted

ALIAS

Return to
front sheet

- 333 -

ALIAS

Fab friendly isometrics

FAB FRIENDLY ISOMETRICS (FFI)

O.S. 128

The FAB FRIENDLY ISOMETRICS System was introduced


for a particular ALIAS client
The System uses SPOOLGEN type on-screen probing methods
to break down and re-assemble parts of long pipelines into
required isometric combinations
The System uses the clients particular (that is, non-general)
working practices

ALIAS

Return to
front sheet

- 334 -

ALIAS

Interactive editing

INTERACTIVE EDITING

O.S. 129

Set this Option Switch to value 1 to obtain the SPOOLGEN


Interactive Editing System (also called Probing)
As stated in the OPTIONS & ATEXT MANUAL - this feature
only operates on PC based computers under MS Windows 3.XX
or Windows NT

ALIAS

Return to
front sheet

- 335 -

ALIAS

Versions

MODIFICATIONS

ISOGEN
Version
Number

1 Mar 95

First Release

V 7.2

1 Jul 96

O.S. 2

New Switch Positions 3 & 4 added.

O.S. 4

Switch Values 3, 4 & 5 added.

O.S. 8

Revised in-line with changes added to O.S. 4.

O.S. 9

Description of settings for Switch Position 1 rewritten.

V7.3

O.S. 21

New Switch Position 3 added.

V 7.7

O.S. 23

New Switch Position 2 Value 2 and Switch Position 3 Value 4 added.

O.S. 24

New Switch Position 2 Value 2 added.

O.S. 27

Switch Values 3, 4 & 5 added.

O.S. 39

New Switch Position 1 Value 2 added.

O.S. 40

New Switch Value 3 added.

O.S. 41

Switch Position 3 now brought into use.

ISSUE

DATE

1.0
2.0

to

New Switch Positions 6, 7 & 8 added.


O.S. 53

New Switch Position 5 added.

O.S. 54

Related Option Switch 77 added.

O.S. 71

Note added to Switch Position 4 Value 4.

O.S. 73

Switch Title & Description revised due to introduction of O.S. 76. Note added to Switch Positions 3 & 4.

O.S. 74

Switch Position 1 Value 3 added.

O.S. 75

New Switch Value 7 added. Related Option


Switch 77 added.

O.S. 76

New Option Switch.

O.S. 77

New Option Switch.

O.S. 109

Switch Position 6 now brought into use.

O.S. 111

New Switch Position 2 added.

Switches
by number
Switches
by name

ALIAS
- 336 -

ISSUE

3.0

DATE

1 Aug 98

MODIFICATIONS
O.S. 128

New Option Switch.

O.S. 7

New Switch Position 3 added.

O.S. 64

New Switch Values 3 & 4 added.

O.S. 2

New Switch Position 5 added.

O.S. 26

New Switch Position 3 added.

O.S. 39

New Switch Position 5 and 6 added.

O.S. 40

New Switch Position 5 added.

O.S. 71

New Values 7 & 8 added to Switch


Positions 1 & 2.

ISOGEN
Version
Number

V 7.8
to
V 7.14.5

O.S. 77

New Switch Position 4 added.

O.S. 109

New Value 2 added to Switch Positions 4 & 5.

O.S. 120

New Switch Positions 4 & 5 added.

O.S. 6

New Switch Position 3 added.

O.S. 21

New Switch values 8 & 9 added.

V 7.16.0

O.S. 53

New Switch Position 6 and 7 added.

V 7.16.0

O.S. 55

New Switch Postions 2 & 3 added.

V 7.16.0

O.S. 78

New Option Switch.

V 7.16.0

31 Jan 00

O.S. 41

New weight output added for Switch Position 4.

V 7.17.7

21 July 00

O.S. 66

New Switch Positions 5 and 6 added.

V 8.3.0

2 Aug 00

O.S. 79

New Option Switch

V 8.4.0

22 Sept 00

O.S. 39

New Switch Position 7 added

V 8.5.1

15 Dec 00

O.S. 95

New Switch Position 3 added

V 8.5.0

15 Dec 00

O.S. 9

Switches 2, 5 and 7 modified

V 8.5.4

15 Dec 00

O.S. 41

Option Switch Position 2,3 and 6 modified

V 8.5.4

15 Dec 00

O.S. 109

Option Switch Position 1 modified

V 8.5.4

1 May 99

V 7.16.0

9 Apr 01

O.S. 8

Option Switch Position 3 modified

V 8.6.0

9 Apr 01

O.S. 9

New Switch Position 8 added

V 8.6.0

9 Apr 01

O.S. 4

New Switch Position 4 added

V 8.6.0

9 Apr 01

O.S. 9

Option Switch Position 6 modified

V 8.7.0

9 Apr 01

O.S. 2

New Switch Position 6 added

v 8.7.0

9 Apr 01

O.S. 31

New Switch Position 2 added

V 8.7.0

3 Jul 01

O.S. 2

Option Switch Position 6 modified

V 8.7.2

3 Jul 01

O.S. 8

Option Switch Position 4 added

V 8.8.0

3 Jul 01

O.S. 39

Option Switch Position 6 modified

V 8.8.0

27 Nov 01

O.S. 71

Option Switch Position 4 and 7 modified

V 8.8.1

17 May 02

O.S. 31

Switch Position 1 modified

V 8.10.0

17 May 02

O.S. 39

Switch Position 3 modified, 8 and 9 added

V 8.10.0

17 May 02

O.S. 54

New Switch Positions 1, 2, 3, 4, 5 and 6 added

V 8.10.0

17 May 02

O.S. 71

Switch Positions 1/3 and 4/6 modified

V 8.10.0

17 May 02

O.S. 75

Switch Positions 1,3 and 5 modified

V 8.10.0

17 May 02

O.S. 75

New Switch Positions 7, 8 and 9 added

V 8.10.0

Switches
by number
Switches
by name

ALIAS
- 337 -

ISSUE

ISOGEN
Version
Number

DATE

MODIFICATIONS

17 May 02

O.S. 76

Switch Position 1 modified

V 8.10.0

17 May 02

O.S. 76

New Switch Positions 2 and 3 added

V 8.10.0

17 May 02

O.S. 77

New Switch Positions 5 and 7 added

V 8.10.0

17 May 02

O.S. 78

Switch Positions 1, 3 and 5 modified

V 8.10.0

17 May 02

O.S. 78

New Switch Positions 7, 8 and 9 added

V 8.10.0

17 May 02

O.S. 79

Switch Position 3 modified

V 8.10.0

17 May 02

O.S. 79

Switch Position 9 added

V 8.10.0

18 Nov 02

O.S. 2

Switch Position 5 modified

V 8.10.5

18 Nov 02

O.S. 24

Switch Position 2 modified

V 8.10.5

2 Apr 03

O.S. 2

Switch Position 7 and 8 added

V.8.11.0

2 Apr 03

O.S. 9

Switch Position 9 added

V.8.11.0

2 Apr 03

O.S. 19

Switch Position 2 added

V.8.11.0

2 Apr 03

O.S. 38

Switch Position 4 added

V.8.11.0

2 Apr 03

O.S. 39

Switch Position 5 modified

V.8.11.0

2 Apr 03

O.S 41

Switch Position 9 added

V.8.11.0

2 Apr 03

O.S 53

Switch Position 8 and 9 added

V.8.11.0

2 Apr 03

O.S 65

Switch Position 3 added

V.8.11.0

2 Apr 03

O.S. 70

Switch Position 3 added

V.8.11.0

2 Apr 03

O.S. 95

Switch Position 4 and 5 added

V.8.11.0

2 Apr 03

O.S. 99

Switch Position 3 added

V.8.11.0

2 Apr 03

O.S. 117

Switch Position 1 modified

V.8.11.0

28 Jan 04

O.S. 74

Switch Position 1,2 & 3 modified

V.8.11.5

28 Jan 04

O.S. 2

Switch Position 9 added

V.8.11.5

23 Feb 04

O.S. 66

Switch Position 7 added

V.8.11.7

23 Feb 04

O.S. 66

Switch Position 8 added

V.8.11.7

23 Feb 04

O.S. 123

Switch Position 4added

V.8.11.7

23 Mar 04

O.S. 9

Switch Position 5 modified

V.8.11.8

16 Jun 04

O.S. 40

Switch Position 6 added

V.8.11.9

16 Jun 04

O.S. 64

Switch Position 1 modified

V.8.11.9

16 Jun 04

O.S. 67

Switch Position 2 added

V.8.11.9

16 Jun 04

O.S. 99

Switch Position 4 added

V.8.11.10

17 Jan 05

O.S. 35

Switch Positions 7-9 added

V.8.12.0

17 Jan 05

O.S. 67

Switch Position 2 modified

V.8.12.0

17 Jan 05

O.S. 72

Switch Positions 1 & 2 added

V.8.12.0

17 Jan 05

O.S. 76

Switch Position 4 added

V.8.12.0

17 Jan 05

O.S. 81

Switch Position 9 added

V.8.12.0

24 Sep 06

O.S. 31

Switch Position 3-5 added

V.8.13.0

24 Sep 06

O.S. 38

Switch Position 4 modified

V.8.13.0

24 Sep 06

O.S. 41

Switch Position 1 modified

V8.13.0

24 Sep 06

O.S. 53

Switch Position 3 modified

V.8.13.0

24 Sep 06

O.S. 54

Switch Position 8 added

V.8.13.0

Switches
by number
Switches
by name

ALIAS
- 338 -

ISSUE

ISOGEN
Version
Number

DATE

MODIFICATIONS

24 Sep 06

O.S. 54

Switch Position 9 added

V.8.13.0

24 Sep 06

O.S. 60/64

Switch Positon 3 added

V.8.13.0

24 Sep 06

O.S. 65

Switch Positions 1 & 2 modified

V.8.13.0

24 Sep 06

O.S. 66

Switch Position 4 added

V.8.13.0

24 Sep 06

O.S. 67

Switch Position 3 added

V.8.13.0

24 Sep 06

O.S. 95

Switch Position 6 added

V.8.13.0

24 Sep 06

O.S. 119

Switch Position 3 added

V.8.13.0

24 Sep 06

O.S. 119

Switch Position 4 added

V.8.13.0

24 Sep 06

O.S. 119

Switch Position 5 added

V.8.13.0

24 Sep 06

O.S. 123

Switch Position 3 modified

V.8.13.0

16 May 07

O.S. 40

Switch Position 1 modified

V.8.13.1

16 May 07

O.S. 83

Switch Position 1 added

V.8.13.1

16 May 07

O.S. 119

Switch Position 2 added

V.8.13.1

14 May 08

O.S. 38

Switch Position 5 added

V.9.0.0

14 May 08

O.S. 38

Switch Position 4 modified

V.9.0.0

14 May 08

O.S. 119

Switch Position 6 added

V.9.0.0

14 May 08

O.S. 123

Switch Position 5 added

V.9.0.0

14 May 08

O.S. 9

Switch Position 1 modified

V.9.0.0

14 May 08

O.S. 121

Switch Position 3 added

V.9.0.0

14 May 08

O.S. 64

Switch Position 4 added

V.9.0.0

14 May 08

O.S. 30

Switch Position 3 added

V.9.0.0

14 May 08

O.S. 84

Switch Positions 1,2 and 3 added

V.9.0.0

14 May 08

O.S. 24

Switch Position 3 added

V.9.0.0

14 May 08

O.S. 116

Switch Position 4-6 added

V.9.0.0

09 Mar 09

O.S. 67

Switch Position 2 modified

V.9.2.0

09 Mar 09

O.S. 67

Switch Position 4 added

V.9.2.0

09 Mar 09

O.S. 70

Switch Position 4 added

V.9.2.0

09 Mar 09

O.S. 114

Switch Position 2 added

V.9.2.0

Switches
by number
Switches
by name

ALIAS
- 339 -

right 19
top 20
Drawing output
file 46
picture scale 49
scaling 47
screen 46
stacking orientation 52
stacking value 51
Drawing size
height 24
standard postscript plotter size 22
width 25
Drawing text size 6
Drawing trim marks 5
Drawing viewpoint 65
DXF file units 141

Index
Click on an Option Switch name/page
number to access switch information.
Where more than one page number is
shown, click on the separate page
numbers to view different sheets relating
to the named switch.

B
Bolting units 94
Bore control 61

C
Centre of Gravity 130
Clear screen 86
Component leg length 144
Component tagging 88
Co-ordinates
connection 8
connectivity 8
supplementary 96
Cut piece add-on allowance
Cut piece list type 2
Cut piece numbering type 2

E
Elevations
vertical 172
Equipment trim drawings 75

F
34

Fab friendly isometrics 183


Flange rotation angles 179
Flow arrows
components 26
pipeline 164

D
Date output 9
Detailed marker 48
Development testing

186, 187, 188, 189, 190,


191, 192, 193, 195, 196
Dimension control 61
Dimension form 15
Dimension line standout 12
Dimensions
branches 128
overall 170
round off 169
to valve centres 126
vertical 172
Drawing
reserved areas 50
Drawing frame
program standard 27
Drawing margin
bottom 21
left 18

Ghost gaps 162

I
Instrument ID enclosure 177
Instrument identification 87
Insulation indication 89
Interactive editing 185
Isogen
run date 182
version 182
Isometric type 32, 33

M
Material control
comdace file contents 139

- 340 -

Switches
by number

ALIAS

comdace file controls 140


pipeline identification 165
Material list
accumulation control 112
continuation method 44
controls 35
descriptions 40
file type 35
item code length 42
line spacing 43
pipeline length units 37
pipeline/drawing 37
position 39
text size 41
Material part number
enclosure shape 117
enclosure style 110

N
Nozzles
dotted 163

P
Pipe support identification
Pipe supports 58
Pipe wastage factor
area 1 66
area 2 67
area 3 68
area 4 69
area 5 70
area 6 71
area 7 72
area 8 73
area 9 74
Pipeline splitting
automatic 53
in tube 159
user control 10
Plotfile
ASCII text 194
DGN link 194
Plotfile format 106
Plotfile length 1
Printed output
page length 91
Program messages
isodat 84
isoplot 85
run information 82

92

R
Repeatability file content 160
Reserved 109, 146, 180, 181
Revision marker 48

S
Skew depiction
dimension line standout 151
hatching clearance 153
individual 147
overall 147
style 149
triangle hatching 152
Skew indication
branches 105
Sloping pipeline
3D skew depiction 99
vertical branches 101
Sloping pipeline indication limit 31
Sloping pipeline indication method 28
Spare switch 121, 124, 132, 133, 134, 135, 136,

137, 138, 142, 143, 148, 154, 155, 156, 157,


158
Specification break indication 166
Spool piece identifiers 55

T
Tapping
branch co-ordinates 176
branch dimensions 175
branch scale 174
Terminal type identification 102
Title block
position 39
Tolerance
angle offset 167
dimension offset 168
Tracing indication 90

W
Weight control 61
Weight output 130
Weld number
enclosure 114
prefix 114
Weld number allocation at slip-on flanges and
reinforcement pads 119
Switches
Weld numbering 77
by number

- 341 -

ALIAS

Weld plotting 80

Switches
by number

- 342 -

ALIAS

How to navigate this file:


Next/previous sheet
(some switches run over more than one sheet)

Next/previous switch
Brings up a table of contents ordered either by
switch name, or by switch number. You can access
any of the switch front sheets from here

Switches
by number
Switches
by name
Details

Accesses switch detail sheet


(if available)

Return to
front sheet

Accesses switch front sheet

Accesses this page

ALIAS

About us:

Alias Limited is situated in the North-West of England. Our business is


software, to design, document, fabricate and maintain piping systems.
Contact us:
Alias Limited
1 Stuart Road
Manor Park
Runcorn
Cheshire
WA7 1TS
England

Telephone:
Fax:
email:

(+44) (0) 1928 579311


(+44) (0) 1928 579389
info@alias.ltd.uk

Switches