Sunteți pe pagina 1din 93

39584

GE Consumer & Industrial


Power Protection

GE Consumer & Industrial

Power Protection (formerly GE Power Controls),


a division of GE Consumer & Industrial,
is a first class European supplier of
low-voltage products including wiring
devices, residential and industrial electrical
distribution components, automation
products, enclosures and switchboards.
Demand for the companys products
comes from, wholesalers, installers,
panel-board builders, contractors, OEMs
and utilities worldwide.

GE Consumer & Industrial


Power Protection

Control and Automation


For industrial applications
Motorstarters

Control and Automation

www.ge.com/ex/powerprotection
www.ge.com/eu/powerprotection

ED.02

GE INDUSTRIAL BELGIUM
POWER PROTECTION
Nieuwevaart 51
B-9000 Gent - Belgium
Tel. +32/9 265 21 11
Fax +32/9 265 28 00
E-mail: gepcbel@gepc.ge.com
GE POWER CONTROLS Ltd
129-135 Camp Road
St Albans
Herts AL1 5HL
United Kingdom
Customer Service
Tel. 0800 587 1251
Fax 0800 587 1239
gepcuk@gepc.ge.com

GE imagination at work

GE imagination at work
680804
Ref. C/4551/E/EX 11.0 Ed. 09/07
Copyright GE Consumer & Industrial 2007

ED.03

Motorstarters

D.2
D.5
D.14

SURION - Fuseless starters


Fuseless starters
Coordination tables
Dimensions

D.19
D.24
D.32

Series M, CL, CK - Direct-on-line starters


Order codes
Diagrams
Dimensions

D.21
D.28
D.34

Series M, CL, CK - Reversing starters


Order codes
Diagrams
Dimensions

D.23
D.30
D.37

Series CL, CK - Star-delta starters


Order codes
Diagrams
Dimensions

D.39
D.42
D.46

Applications
Utilisation categories
Electrical endurance
DC utilisation categories

D.49
D.52
D.56

Selection tables
Direct-on-line starters
Star-delta starters
Autotransformer starters

Plug-in relays and Auxiliary contactors

Motor protection devices

Contactors and Thermal overload relays

Motorstarters

Control and signalling units

Electronic relays

Limit switches

Speed drive units

Main switches

Numerical index


D.58
D.60
D.62
D.63
D.64

Contactors for rotor starters


Contactors for rotor speed drives
Contactors for connection of power transformers
Contactors for capacitors (category AC6b)
Contactors for control lighting circuits

D.67
D.68
D.69
D.70

ASTAT S - Softstarters
Order codes
Diagrams
Performance
Dimensions

D.72
D.74
D.75
D.76
D.77
D.78
D.79
D.80
D.84
D.86

ASTAT XT Digital Soft Starters


Order codes
Unit configuration
Technical Data
Functions
Overload protections
I/O Wiring
I/O terminal board specifications
Wiring diagrams
Coordination tables
Dimensions and weights

NEW

D.1

Surion

Manual motorstarter

Fuseless starters and busbar adapter plates

Product range

Link modules for mechanical and electrical connection of the manual motor
starter and the M / CL contactor range
Base plates for Din rail and busbar adapters
Wiring kits for reversing applications
Link connection for two base plates for three phase busbar system with 40
and 60mm center line spacing and 5 to 10mm thickness
Accessories

B
C
D

Technical performances

Compact and high performance solution


Easy accessibility to the contactor coil terminal A1-A2
Save spacing only using 45 and 55mm width base plates for busbar
adapters
Quick clip on and secure connections
Minimum 50kA short-circuit breaking capacity applies throughout

F
G
H

Thermal and
magnetic protection
GPS1B
GPS2B
GPS1M
GPS2M

I
X

!
!
!
!

pg. B.8
pg. B.10
pg. B.12
pg. B.14

Contactors
Serie M ! pg. C.2
Serie CL ! pg. C.10
Coordination tables ! pg. D.5
Dimensions ! pg. D.14

D.2

For fuseless starter application turn the contactor 180 to have direct
accessibility to the A1-A2 coil terminals when contactor is assembled to the
manual motor starter. Then fit the contactor plastic cover into the contactor
front to have the terminal numbering in the correct position.
Note: when turning the contactor 180 the built-in auxiliary contact (in case)
will be located on the first left side terminal.

Surion
Fuseless starters
Description

Link modules

Base plates
Link
connector

Frame size

Cat. no.

Ref. no.

Pack.

ac/dc
ac
dc
ac
dc
ac
dc

GPS1
GPS1
GPS1
GPS1
GPS1
GPS1
GPS1

GPF1LMCBA
GPF1L02AA
GPF1L02DA
GPF1L25AA
GPF1L25DA
GPF1L04AA
GPF1L04DA

101410
101411
101412
101413
101414
107165
107166

5
5
5
5
5
5
5

CL03A.., CL04A..
CL45A..
CL03D.., CL04D..
CL45D..
CL06A.., CL07A..
-

ac
ac
dc
dc
ac
-

GPS2
GPS2
GPS2
GPS2
GPS2
-

GPF2L04AA
GPF2L45AA
GPF2L04DA
GPF2L45DA
GPF2L07AA
GPF3L09AA

107190
101415
107191
101416
101417
107252

5
5
5
5
5
1

CL00.. - CL25
CL03.. - CL45

ac/dc
ac/dc

GPS1
GPS2

GPF1L25CT1 101512
GPF1L45CT1 101513

5
5

ac/dc
ac/dc
ac/dc
ac/dc

GPS1
GPS2
GPS2
GP

GPF1B1A
GPF2B2A
GPF2B3A
GPF1B4A

101418
101419
101420
107163

5
5
5
5

Plastic plates for mounting the CL00.., CL01..,CL02..,CL25..


fuseless starter in panels or in 35 CL03..,CL04... and CL45..
mm DIN rail
CL06..,CL07..
CL03.., CL04..
For use with MCCB Record Plus

GPF3B5A

107253

For two base plates for


reversing applications

GPF1CBA

101427

10

Suitable to be usd with link


modules
Upper and lower connections
without overload relays

MC0.., MC1.., MC2..


CL00.., CL01.., CL02..
CL25..
CL03.., CL04...
CL45..
CL06A.., CL07A.

ac/dc
ac/dc
ac/dc
ac/dc
ac/dc
ac

WKMIU
WKLI02P
WKLI25P
WKLI04P
WKLI45P
WKLI07P

101421
101422
101423
101424
101425
101426

1
1
1
1
1
1

Cat. no.

Ref. no.

Pack.

GPF00C02

107098

GPF10C02

107099

GPF01C02

107100

GPF00C25
GPF00C04

107101
107102

2
5

GPF10C04

107103

GPF01C04

107105

GPF00C45
GPF00C08

107106
107107

5
5

Order codes

For use with MCCB


Record Plus withCL09/10A
For mechanical and electrical
connection between contactor
and thermal overload relays RT1

Base plates

ac/dc

For use with


contactor
For mechanical and electrical
MC0.., MC1..
connection between contactors CL00A.., CL01A.., CL02A..
and manual motor starters
CL00D.., CL01D.., CL02D..
CL25A..
CL25D..
CL03A.., CL04A
CL03D.., CL04D

A
Wiring kits
for reversing
starters

Description

Plastic cover

Fit the plastic cover into the front


of the correspondent contactor
to allow a clear identification of
the terminal numbering

For use with


contactor
CL00.., CL01.. and CL02
without built-in auxiliary contact
CL00.., CL01.. and CL02
with built-in 1NO auxiliary contact
CL00.., CL01.. and CL02
with built-in 1NC auxiliary contact
CL25..
CL03.., CL04..
without built-in auxiliary contact
CL03.., CL04..
with built-in 1NO auxiliary contact
CL03.., CL04..
with built-in 1NC auxiliary contact
CL45..
CL06.., CL07..

B
C
D
E
F
G
H
I
X

D.3

Manual motorstarter

Surion

A
B
C
D
E
F
G
H
I
X

D.4

Notes
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

Surion
Technical data
Surion GPS-B: Coordination Type 1 65kA at 380/400V and 415V
MOTOR (1)
Rated
power

Rated current

Rated
current
In

Cat. no.

380/400V 415V
(A)
0.23
0.21
0.34
0.31
0.44
0.4
0.65
0.63
0.9
0.8
1.25
1.1
1.6
1.5
2
1.9
2.6
2.5
3.5
3.4
5
4.5
7
6.5
9
8
12
11
16
14
22.5
21
30
28
22.5
21
30
28
37
35
44
41
60
55

GPS1BSAB
GPS1BSAC
GPS1BSAD
GPS1BSAE
GPS1BSAE
GPS1BSAF
GPS1BSAF
GPS1BSAG
GPS1BSAH
GPS1BSAH
GPS1BSAJ
GPS1BSAK
GPS1BSAK
GPS1BHAL
GPS1BHAM
GPS1BHAP
GPS1BHAR
GPS2BHAP
GPS2BHAR
GPS2BHAS
GPS2BHAT
GPS2BHAU

(A)
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
13
16
25
32
25
32
40
50
63

CONTACTOR

Thermal
current

Magnetic
current

Setting
range
(A)
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
0.63 - 1
1 - 1.6
1 - 1.6
1.6 - 2.5
2.5 - 4
2.5 - 4
4 - 6.3
6.3 - 10
6.3 - 10
9 - 13
11 - 16
19 - 25
24 - 32
19 - 25
24 - 32
28 - 40
35 - 50
45 - 63

(A)
3.2
5.2
8.2
13
13
20.5
20.5
32.5
52
52
82
130
130
169
208
325
416
325
416
520
650
820

Series

MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC1 / CL00
MC1 / CL00
CL01
CL02
CL25
CL04
CL04
CL04
CL45
CL06
CL07

LINKS
Smallest Minimum
Cat. no.
wire
frontal
(3)
Cu
electrical
(PVC)(2)
safety
380/415V clearance
2
(mm )
(mm)
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1.5
20
GPF1LMCBA / GPF1L02*
1.5
20
GPF1LMCBA / GPF1L02*
2.5
20
GPF1L02*
2.5
20
GPF1L02*
4
20
GPF1L25*
6
20
GPF1L04*
4
20
GPF2L04*
6
20
GPF2L04*
10
20
GPF2L45*
10
25
GPF2L07AA
16
25
GPF2L07AA

Technical data

(kW)
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
11
15
18.5
22
30

MANUAL MOTOR STARTER

A
B

Surion GPS-B: Coordination Type 2 65kA at 380/400V and 415V


MOTOR (1)
Rated
power

(kW)
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
11
15
18.5
22
30

MANUAL MOTOR STARTER

Rated current

Cat. no.


380/400V 415V
(A)
0.23
0.21
0.34
0.31
0.44
0.4
0.65
0.63
0.9
0.8
1.25
1.1
1.6
1.5
2
1.9
2.6
2.5
3.5
3.4
5
4.5
7
6.5
9
8
12
11
16
14
22.5
21
30
28
22.5
21
30
28
37
35
44
41
60
55

GPS1BHAB
GPS1BHAC
GPS1BHAD
GPS1BHAE
GPS1BHAE
GPS1BHAF
GPS1BHAF
GPS1BHAG
GPS1BHAH
GPS1BHAH
GPS1BHAJ
GPS1BHAK
GPS1BHAK
GPS1BHAL
GPS1BHAM
GPS1BHAP
GPS1BHAR
GPS2BHAP (4)
GPS2BHAR (4)
GPS2BHAS (4)
GPS2BHAT (4)
GPS2BHAU (4)

Rated
current
In
(A)
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
13
16
25
32
25
32
40
50
63

Thermal
current
Setting
range
(A)
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
0.63 - 1
1 - 1.6
1 - 1.6
1.6 - 2.5
2.5 - 4
2.5 - 4
4 - 6.3
6.3 - 10
6.3 - 10
9 - 13
11 - 16
19 - 25
24 - 32
19 - 25
24 - 32
28 - 40
35 - 50
45 - 63

CONTACTOR
Magnetic
current

(A)
3.2
5.2
8.2
13
13
20.5
20.5
32.5
52
52
82
130
130
169
208
325
416
325
416
520
650
820

Series

CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL25
CL25
CL25
CL25
CL25
CL25
CL25
CL25
CL04
CL04
CL04
CL45
CL06
CL07

LINKS
Smallest Minimum
wire
frontal
Cu
electrical
(PVC)(2)
safety
380/415V clearance
2
(mm )
(mm)
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1.5
20
1.5
20
2.5
20
2.5
20
4
20
6
20
4
20
6
20
10
20
10
25
16
25

Cat. no.
(3)

D
GPF1L02*
GPF1L02*
GPF1L02*
GPF1L02*
GPF1L02*
GPF1L02*
GPF1L02*
GPF1L02*
GPF1L25*
GPF1L25*
GPF1L25*
GPF1L25*
GPF1L25*
GPF1L25*
GPF1L25*
GPF1L25*
GPF1L04*
GPF2L04*
GPF2L04*
GPF2L45*
GPF2L07*
GPF2L07*

E
F
G
H
I
X

(1)

(2)

Currents are relevant to four pole motors not having special characteristics of torque.
Inrush currents: 8 time rated current for 1s.
The minimum cycle cross-sections are referred to an ambient temperature of 30C max. in free air.
Cables are to withstand the maximum let-through energy and the motor rated current. Besides the user should consider the drop voltage on
the cables, the type of laying and the ambient temperature.
(3) Complete cat. nrs., see page D.3
(4) Test running.

D.5

Surion
Surion GPS-B: Coordination Type 1 50kA at 500V and 525V
MOTOR (1)
Rated
power

Rated current

Manual motorstarter
B

Cat. no.

Rated
current
In

MANUAL MOTOR STARTER

(kW)
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
10
11
15
18.5
11
15
18.5
22
30
37

500V

525V
(A)

0.17
0.24
0.33
0.48
0.66
0.9
1.2
1.5
2.1
2.8
3.9
5.3
6.8
9.1
12
15.5
17.6
23
28.5
17.6
23
28.5
33
45
53

GPS1BSAB
GPS1BSAB
GPS1BSAC
GPS1BSAD
GPS1BSAE
GPS1BSAE
GPS1BSAF
GPS1BSAF
GPS1BSAG
GPS1BSAH
GPS1BSAH
GPS1BSAJ
GPS1BHAK
GPS1BHAK
GPS1BHAL
GPS1BHAM
GPS1BHAN
GPS1BHAP
GPS1BHAR
GPS2BHAN
GPS2BHAP
GPS2BHAR
GPS2BHAS
GPS2BHAT
GPS2BHAU

0.16
0.22
0.3
0.46
0.64
0.85
1.15
1.45
1.9
2.6
3.6
5
6.5
8.6
11.4
14.8
17
22
27
17
22
27
31.5
43
52

(A)
0.25
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
13
16
20
25
32
20
25
32
40
50
63

CONTACTOR

Thermal
current

Magnetic
current

Setting
range
(A)
0.16 - 0.25
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
0.63 - 1
1 - 1.6
1 - 1.6
1.6 - 2.5
2.5 - 4
2.5 - 4
4 - 6.3
6.3 - 10
6.3 - 10
9 - 13
11 - 16
14 - 20
19 - 25
24 - 32
14 - 20
19 - 25
24 - 32
28 - 40
35 - 50
45 - 63

(A)
3.2
3.2
5.2
8.2
13
13
20.5
20.5
32.5
52
52
82
130
130
169
208
260
325
416
260
325
416
520
650
820

Series

MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC0 / CL00
MC1 / CL00
CL00
CL01
CL02
CL25
CL25
CL04
CL04
CL04
CL04
CL45
CL06
CL07

LINKS
Smallest Minimum
Cat. no.
wire
frontal
(3)
Cu
electrical
(PVC)(2)
safety
380/415V clearance
2
(mm )
(mm)
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1.5
20
GPF1L02*
2.5
20
GPF1L02*
2.5
20
GPF1L02*
2.5
20
GPF1L25*
4
20
GPF2L25*
6
20
GPF1L04*
2.5
20
GPF2L04*
4
20
GPF2L04*
6
20
GPF2L04*
6/10
20
GPF2L45*
10
25
GPF2L07*
16
25
GPF2L07*

Surion GPS-B: Coordination Type 2 50kA at 500V and 525V

MOTOR (1)
Rated
power

Rated current

(kW)
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
10
11
15
18.5
11
15
18.5
22
30
37

E
F
G
H
I
X

MANUAL MOTOR STARTER


Cat. no.


500V

525V
(A)

0.17
0.24
0.33
0.48
0.66
0.9
1.2
1.5
2.1
2.8
3.9
5.3
6.8
9.1
12
15.5
17.6
23
28.5
17.6
23
28.5
33
45
53

Rated
current
In

0.16
0.22
0.3
0.46
0.64
0.85
1.15
1.45
1.9
2.6
3.6
5
6.5
8.6
11.4
14.8
17
22
27
17
22
27
31.5
43
52

GPS1BS/HAB
GPS1BS/HAB
GPS1BS/HAC
GPS1BS/HAD
GPS1BS/HAE
GPS1BS/HAE
GPS1BS/HAF
GPS1BS/HAF
GPS1BS/HAG
GPS1BS/HAH
GPS1BS/HAH
GPS1BS/HAJ
GPS1BHAK
GPS1BHAK
GPS1BHAL
GPS1BHAM
GPS1BHAN
GPS1BHAP
GPS1BHAR
GPS2BHAN
GPS2BHAP
GPS2BHAR
GPS2BHAS
GPS2BHAT
GPS2BHAU

(A)
0.25
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
13
16
20
25
32
20
25
32
40
50
63

CONTACTOR

Thermal
current

Magnetic
current

Setting
range
(A)
0.16- 0.25
0.16 - 0.25
0.25 - 0.4
0.4 0.63
0.63 - 1
0.63 - 1
1 - 1.6
1 - 1.6
1.6 2.5
2.5 - 4
2.5 - 4
4 - 6.3
6.3 10
6.3 10
9 13
11 16
14 - 20
19 - 25
24 - 32
14 - 20
19 - 25
24 - 32
28 40
35 50
45 - 63

(A)
3.2
3.2
5.2
8.2
13
13
20.5
20.5
32.5
52
52
82
130
130
169
208
260
325
416
260
325
416
520
650
820

Series

MC1 / CL00
MC1 / CL00
MC1 / CL00
MC1 / CL00
MC1 / CL00
MC1 / CL00
MC1 / CL00
MC1 / CL00
CL00
CL25
CL25
CL25
CL25
CL25
CL25
CL25
CL25
CL04
CL04
CL04
CL04
CL45
CL06
CL06
CL07

LINKS
Smallest Minimum
Cat. no.
wire
frontal
(3)
Cu
electrical
(PVC)(2)
safety
380/415V clearance
2
(mm )
(mm)
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1L02*
1
20
GPF1L25*
1
20
GPF1L25*
1
20
GPF1L25*
1
20
GPF1L25*
1.5
20
GPF1L25*
2.5
20
GPF1L25*
2.5
20
GPF1L25*
2.5
20
GPF1L25*
4
20
GPF1L04*
6
20
GPF1L04*
2.5
20
GPF2L04*
4
20
GPF2L04*
6
20
GPF2L45*
6/10
25
GPF2L07*
10
25
GPF2L07*
16
25
GPF2L07*

(1) Currents are relevant to four pole motors not having special characteristics of torque. Inrush currents: 8 time rated current for 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30C max. in free air. Cables are to withstand the maximum let-through
energy and the motor rated current. Besides the user should consider the drop voltage on the cables, the type of laying and the ambient temperature.
(3) Complete cat. nrs., see page D.3

D.6

Surion
Surion GPS-M and Record Plus: Coordination Type 1 65kA at 380/400V and 415V
MOTOR (1)
Rated
power

380/400V 415V
(A)
0.23
0.21
0.34
0.31
0.44
0.4
0.65
0.63
0.9
0.8
1.25
1.1
1.6
1.5
2
1.9
2.6
2.5
3.5
3.4
5
4.5
7
6.5
9
8
12
11
14
16
22.5
21
30
28
22.5
21
30
28
37
35
40
44
60
55
85
80
100
105
-

Cat. no.

GPS1MSAB
GPS1MSAC
GPS1MSAD
GPS1MSAE
GPS1MSAE
GPS1MSAF
GPS1MSAF
GPS1MSAG
GPS1MSAH
GPS1MSAH
GPS1MSAJ
GPS1MSAK
GPS1MSAK
GPS1MHAL
GPS1MHAM
GPS1MHAM
GPS1MHAP
GPS1MHAR
GPS2MHAP
GPS2MHAR
GPS2MHAS
GPS2MHAT
GPS2MHAT
GPS2MHAU
FDH36MC100GD
FDH36MC160JF
FDH36MC160JF

Rated
Magnetic
Magnetic
current setting Im
current
In
Pick-up band
20% Im
(A)
(A)
(A)
0.25
3.3
0.4
5.2
0.63
8.2
1
13
1
13
1.6
20.8
1.6
20.8
2.5
32.5
4
52
4
52
6.3
81.9
10
130
10
130
13
169
16
208
16
208
25
325
32
416
25
325
32
416
40
520
50
650
50
650
63
819
100
1000 - 1500
1140
160
1600 - 2400
1400
160
1600 - 240
1400

CONTACTOR

OVERLOAD RELAY

Series

Series

Setting
range

CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL01
CL02
CL02
CL25
CL04
CL04
CL04
CL45
CL06
CL06
CL07
CL09
CL10
CL10

RT1B
RT1C
RT1D
RT1D
RT1F
RT1G
RT1H
RT1J
RT1K
RT1K
RT1L
RT1M
RT1N
RT1P
RT1P
RT1S
RT1U
RT1V
RT1U
RT1V
RT1W
RT2E
RT2G
RT2H
RT2L
RT2M
RT2M

0.16-0.26
0.25-0.41
0.4-0.65
0.4-0.65
0.65-1.1
1-1.5
1.3-1.9
1.8-2.7
2.5-4
2.5-4
4-6.3
5.5-8.5
8-12
10-16
10-16
14.5-18
21-26
25-32
21-26
25-32
30-40
30-43
42-55
54-65
78 97
90 - 110
90 - 110

Smallest
Min
wire Cu
frontal
(PVC) (2)
safety
380/415V clearance
2
(mm )
(mm)
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1.5
20
1.5
20
2.5
20
2.5
20
2.5
20
4
20
6
20
4
20
6
20
10
20
10
25
10
25
16
25
35
30
35
30
35
30

Technical data

(kW)
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
7.5
11
15
11
15
18.5
22
22
30
45
55
55

Rated current

BREAKER

A
B
C

Surion GPS-M and Record Plus: Coordination Type 2 65kA at 380/400V and 415V
MOTOR (1)
Rated
power
(kW)
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
7.5
11
15
11
15
18.5
22
22
30
45
55
55

Rated current
380/400V 415V
(A)
0.23
0.21
0.34
0.31
0.44
0.4
0.65
0.63
0.9
0.8
1.25
1.1
1.6
1.5
2
1.9
2.6
2.5
3.5
3.4
5
4.5
7
6.5
9
8
12
11
14
16
22.5
21
30
28
22.5
21
30
28
37
35
40
44
60
55
85
80
100
105
-

BREAKER
Cat. no.

GPS1MHAB
GPS1MHAC
GPS1MHAD
GPS1MHAE
GPS1MHAE
GPS1MHAF
GPS1MHAF
GPS1MHAG
GPS1MHAH
GPS1MHAH
GPS1MHAJ
GPS1MHAK
GPS1MHAK
GPS1MHAL
GPS1MHAM
GPS1MHAM
GPS2MHAP
GPS2MHAR
GPS2MHAP
GPS2MHAR
GPS2MHAS
GPS2MHAT
GPS2MHAT
GPS2MHAU
FDH36MC100GD
FDH36MC100GD
FDH36MC160JF

Rated
Magnetic
Magnetic
current setting Im
current
In
Pick-up band
20% Im
(A)
(A)
(A)
0.25
3.3
0.4
5.2
0.63
8.2
1
13
1
13
1.6
20.8
1.6
20.8
2.5
32.5
4
52
4
52
6.3
81.9
10
130
10
130
13
169
16
208
16
208
25
325
32
416
25
325
32
416
40
520
50
650
50
650
63
819
100
1000 - 1500
1140
100
1000 - 1500
1400
160
1600 - 2400
1400

CONTACTOR

OVERLOAD RELAY

Series

Series

Setting
range

CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL25
CL25
CL25
CL25
CL25
CL25
CL25
CL25
CL25
CL04
CL04
CL04
CL45
CL06
CL06
CL07
CL09
CL10
CL10

RT1B
RT1C
RT1D
RT1D
RT1F
RT1G
RT1H
RT1J
RT1K
RT1K
RT1L
RT1M
RT1N
RT1P
RT1P
RT1S
RT1U
RT1V
RT1U
RT1V
RT1W
RT2E
RT2G
RT2H
RT2L
RT2M
RT2M

0.16-0.26
0.25-0.41
0.4-0.65
0.4-0.65
0.65-1.1
1-1.5
1.3-1.9
1.8-2.7
2.5-4
2.5-4
4-6.3
5.5-8.5
8-12
10-16
10-16
14.5-18
21-26
25-32
21-26
25-32
30-40
30-43
42-55
54-65
78 97
90 - 110
90 - 110

Smallest
Min
wire Cu
frontal
(PVC) (2)
safety
380/415V clearance
(mm2)
(mm)
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1.5
20
1.5
20
2.5
20
2.5
20
2.5
20
4
20
6
20
4
20
6
20
10
20
10
25
10
25
16
25
35
30
35
30
35
30

D
E
F
G
H
I
X

(1) Current are relevant to four pole motors not having special characteristics of torque. Inrush currents: H 8 time rated current for H 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30C max. in free air and are selected to withstand the maximum let-through
energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.

D.7

Surion
Surion GPS-B: Coordination Type 2 50kA at 380/400V and 415V
MOTOR (1)
Rated
power

Rated current

Manual motorstarter
A

Cat. no.



(kW)
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
11
15
18.5
22
30

MANUAL MOTOR STARTER

380/400V 415V
(A)
0.23
0.21
0.34
0.31
0.44
0.4
0.65
0.63
0.9
0.8
1.25
1.1
1.6
1.5
2
1.9
2.6
2.5
3.5
3.4
5
4.5
7
6.5
9
8
12
11
16
14
22.5
21
30
28
22.5
21
30
28
37
35
44
41
60
55

GPS1BS/HAB
GPS1BS/HAC
GPS1BS/HAD
GPS1BS/HAE
GPS1BS/HAE
GPS1BS/HAF
GPS1BS/HAF
GPS1BS/HAG
GPS1BS/HAH
GPS1BS/HAH
GPS1BS/HAJ
GPS1BS/HAK
GPS1BS/HAK
GPS1BHAL
GPS1BHAM
GPS1BHAP
GPS1BHAR
GPS2BHAP
GPS2BHAR
GPS2BHAS
GPS2BHAT
GPS2BHAU

Rated
current
In
(A)
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
13
16
25
32
25
32
40
50
63

CONTACTOR

Thermal
current

Magnetic
current

Setting
range
(A)
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
0.63 - 1
1 - 1.6
1 - 1.6
1.6 - 2.5
2.5 - 4
2.5 - 4
4 - 6.3
6.3 - 10
6.3 - 10
9 - 13
11 - 16
19 - 25
24 - 32
19 - 25
24 - 32
28 - 40
35 - 50
45 - 63

(A)
3.2
5.2
8.2
13
13
20.5
20.5
32.5
52
52
82
130
130
169
208
325
416
325
416
520
650
820

Series

MC1 / CL00
MC1 / CL00
MC1 / CL00
MC1 / CL00
MC1 / CL00
MC1 / CL00
MC1 / CL00
MC1 / CL00
CL01
CL01
CL02
CL25
CL25
CL25
CL25
CL25
CL04
CL04
CL04
CL45
CL06
CL07

LINKS
Smallest Minimum
Cat. no.
wire
frontal
(3)
Cu
electrical
(PVC)(2)
safety
380/415V clearance
2
(mm )
(mm)
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1LMCBA / GPF1L02*
1
20
GPF1L02*
1
20
GPF1L02*
1
20
GPF1L02*
1.5
20
GPF1L25*
1.5
20
GPF1L25*
2.5
20
GPF1L25*
2.5
20
GPF1L25*
4
20
GPF1L25*
6
20
GPF1L04*
4
20
GPF2L04*
6
20
GPF2L04*
10
20
GPF2L45*
10
25
GPF2L07*
16
25
GPF2L07*

(1) Currents are relevant to four pole motors not having special characteristics of torque.
Inrush currents: H 8 time rated current for H 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30C max. in free air. Cables are to withstand the maximum let-through
energy and the motor rated current. Besides the user should consider the drop voltage on the cables, the type of laying and the ambient temperature.
(3) Complete cat. nrs., see page D.3

B
C
D
E
F
G
H
I
X

D.8

Surion
Surion GPS-M and Record Plus: Coordination Type 1 65kA at 380/400V and 415V
MOTOR (1)
Rated
power

380/400V 415V
(A)
0.23
0.21
0.34
0.31
0.44
0.4
0.65
0.63
0.9
0.8
1.25
1.1
1.6
1.5
2
1.9
2.6
2.5
3.5
3.4
5
4.5
7
6.5
9
8
12
11
14
16
22.5
21
30
28
22.5
21
30
28
37
35
40
44
60
55
72
68
85
80
105
100

Cat. no.

GPS1MS/HAB
GPS1MS/HAC
GPS1MS/HAD
GPS1MS/HAE
GPS1MS/HAE
GPS1MS/HAF
GPS1MS/HAF
GPS1MS/HAG
GPS1MS/HAH
GPS1MS/HAH
GPS1MS/HAJ
GPS1MS/HAK
GPS1MS/HAK
GPS1MHAL
GPS1MHAM
GPS1MHAM
GPS1MHAP
GPS1MHAR
GPS2MHAP
GPS2MHAR
GPS2MHAS
GPS2MHAT
GPS2MHAT
GPS2MHAU
FDN36MC080GD
FDN36MC100GD
FDN36MC100GD

CONTACTOR

Rated
current
In

Thermal
current

Magnetic
current

(A)
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
13
16
16
25
32
25
32
40
50
50
63
80
100
100

(A)
-

(A)
3.3
5.2
8.2
13
13
20.8
20.8
32.5
52
52
81.9
130
130
169
208
208
325
416
325
416
520
650
650
819
950
1140
1400

OVERLOAD RELAY

Series

Series

Setting
range

CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL01
CL02
CL02
CL25
CL04
CL25
CL04
CL45
CL06
CL06
CL07
CL08
CL09
CL10

RT1B
RT1C
RT1D
RT1D
RT1F
RT1G
RT1H
RT1J
RT1K
RT1K
RT1L
RT1M
RT1N
RT1P
RT1P
RT1S
RT1U
RT1V
RT1U
RT1V
RT1W
RT2E
RT2G
RT2H
RT2J
RT2L
RT2M

0.16-0.26
0.25-0.41
0.4-0.65
0.4-0.65
0.65-1.1
1-1.5
1.3-1.9
1.8-2.7
2.5-4
2.5-4
4-6.3
5.5-8.5
8-12
10-16
10-16
14.5-18
21-26
25-32
21-26
25-32
30-40
30-43
42-55
54-65
64-82
78-97
90-110

Smallest
Min
wire Cu
frontal
(PVC) (2)
safety
380/415V clearance
2
(mm )
(mm)
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1.5
20
1.5
20
2.5
20
2.5
20
2.5
20
4
20
6
20
4
20
6
20
10
20
10
25
10
25
16
25
25
25
35
30
35
30

Technical data

(kW)
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
7.5
11
15
11
15
18.5
22
22
30
37
45
55

Rated current

BREAKER

A
B
C

Surion GPS-M and Record Plus: Coordination Type 2 50kA at 380/400V and 415V
MOTOR (1)
Rated
power
(kW)
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
7.5
11
15
11
15
18.5
22
22
30
37
45
55

Rated current
380/400V 415V
(A)
0.23
0.21
0.34
0.31
0.44
0.4
0.65
0.63
0.9
0.8
1.25
1.1
1.6
1.5
2
1.9
2.6
2.5
3.5
3.4
5
4.5
7
6.5
9
8
12
11
14
16
22.5
21
30
28
22.5
21
30
28
37
35
40
44
60
55
72
68
85
80
105
100

BREAKER
Cat. no.

GPS1MS/HAB
GPS1MS/HAC
GPS1MS/HAD
GPS1MS/HAE
GPS1MS/HAE
GPS1MS/HAF
GPS1MS/HAF
GPS1MS/HAG
GPS1MS/HAH
GPS1MS/HAH
GPS1MS/HAJ
GPS1MS/HAK
GPS1MS/HAK
GPS1MHAL
GPS1MHAM
GPS1MHAM
GPS1MHAP
GPS1MHAR
GPS2MHAP
GPS2MHAR
GPS2MHAS
GPS2MHAT
GPS2MHAT
GPS2MHAU
FDN36MC080GD
FDN36MC100GD
FDN36MC100GD

CONTACTOR

Rated
current
In

Thermal
current

Magnetic
current

(A)
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
13
16
16
25
32
25
32
40
50
50
63
80
100
100

(A)
-

(A)
3.3
5.2
8.2
13
13
20.8
20.8
32.5
52
52
81.9
130
130
169
208
208
325
416
325
416
520
650
650
819
950
1140
1400

OVERLOAD RELAY

Series

Series

Setting
range

CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL01
CL01
CL02
CL25
CL25
CL25
CL25
CL25
CL25
CL04
CL04
CL04
CL45
CL06
CL06
CL07
CL08
CL09
CL10

RT1B
RT1C
RT1D
RT1D
RT1F
RT1G
RT1H
RT1J
RT1K
RT1K
RT1L
RT1M
RT1N
RT1P
RT1P
RT1S
RT1U
RT1V
RT1U
RT1V
RT1W
RT2E
RT2G
RT2H
RT2J
RT2L
RT2M

0.16-0.26
0.25-0.41
0.4-0.65
0.4-0.65
0.65-1.1
1-1.5
1.3-1.9
1.8-2.7
2.5-4
2.5-4
4-6.3
5.5-8.5
8-12
10-16
10-16
14.5-18
21-26
25-32
21-26
25-32
30-40
30-43
42-55
54-65
64-82
78-97
90-110

Smallest
Min
wire Cu
frontal
(PVC) (2)
safety
380/415V clearance
(mm2)
(mm)
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1.5
20
1.5
20
1.5
20
2.5
20
2.5
20
4
20
6
20
4
20
6
20
6
20
10
25
10
25
16
25
25
25
35
30
35
30

D
E
F
G
H
I
X

(1) Current are relevant to four pole motors not having special characteristics of torque. Inrush currents: H 8 time rated current for H 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30C max. in free air and are selected to withstand the maximum
let-through energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.

D.9

Surion
Surion GPS-M and Record Plus: Coordination Type 1 50kA at 500 and 525V
MOTOR (1)
Rated
power

BREAKER

Rated current

Manual motorstarter

500V

A
B

(kW)
0.06
0.09
0.12
0.18
0.25
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
10
11
15
18.5
11
15
18.5
22
30
37
45
45
55

Cat. no.

525V
(A)

0.17
0.24
0.33
0.48
0.66
0.9
1.2
1.5
2.1
2.8
3.9
5.3
6.8
9.1
12
15.5
17.6
23
28.5
17.6
23
28.5
33
45
53
65
80

0.16
0.22
0.3
0.46
0.64
0.85
1.15
1.45
1.9
2.6
3.6
5
6.5
8.6
11.4
14.8
17
22
27
17
22
27
31.5
43
52
62
76

GPS1MSAB
GPS1MSAB
GPS1MSAC
GPS1MSAD
GPS1MSAE
GPS1MSAE
GPS1MSAE
GPS1MSAF
GPS1MSAF
GPS1MSAG
GPS1MSAH
GPS1MSAH
GPS1MSAJ
GPS1MHAK
GPS1MHAK
GPS1MHAL
GPS1MHAM
GPS1MHAN
GPS1MHAP
GPS1MHAR
GPS2MHAN
GPS2MHAP
GPS2MHAR
GPS2MHAS
GPS2MHAT
GPS2MHAU
FDN36MC080GD
FDN36MC080GD
FDN36MC100GD

Rated
Magnetic Magnetic
current setting Im
current
In
Pick-up band
20% Im
(A)
(A)
(A)
0.25
3.2
0.25
3.2
0.4
5.2
0.63
8.2
1
13
1
13
1
13
1.6
20.5
1.6
20.5
2.5
32.5
4
52
4
52
6.3
82
10
130
10
130
13
169
16
208
20
260
25
325
32
416
20
260
25
325
32
416
40
520
50
650
63
820
80
800 - 1200
1000
80
800 - 1200
1000
100
1000 - 150
1200

CONTACTOR

OVERLOAD RELAY

Series

Series

Setting
range

CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL01
CL02
CL25
CL25
CL04
CL04
CL04
CL04
CL45
CL06
CL07
CL08
CL08
CL09

RT1B
RT1B
RT1C
RT1D
RT1D
RT1F
RT1F
RT1G
RT1H
RT1J
RT1K
RT1K
RT1L
RT1M
RT1N
RT1P
RT1S
RT1S
RT1U
RT1V
RT1S
RT1U
RT1V
RT2E
RT2G
RT2G
RT2H
RT2J
RT2J

0.16-0.26
0.16-0.26
0.25-0.41
0.4-0.65
0.4-0.65
0.65-1.1
0.65-1.1
1.0-1.5
1.3-1.9
1.8-2.7
2.5-4
2.5-4
4.0-6.3
5.5-8.5
8.0-12.0
10-16
14.5-18
14.5-18
21-26
25-32
14.5-18
21-26
25-32
30-43
42-55
42-55
54 65
64 82
64 82

Smallest
Min
wire Cu
frontal
(PVC) (2)
safety
380/415V clearance
2
(mm )
(mm)
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1.5
20
2.5
20
2.5
20
2.5
20
4
20
6
20
2.5
20
4
20
6
20
6/10
20
10
25
16
25
16
30
25
30
25
30

C
Surion GPS-M and Record Plus: Coordination Type 2 50kA at 500 and 525V

D
E
F
G
H
I
X

D.10

MOTOR (1)
Rated
power

BREAKER

Rated current
500V

(kW)
0.06
0.09
0.12
0.18
0.25
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
10
11
15
18.5
11
15
18.5
22
30
37
45
45
55

Cat. no.

525V
(A)

0.17
0.24
0.33
0.48
0.66
0.9
1.2
1.5
2.1
2.8
3.9
5.3
6.8
9.1
12
15.5
17.6
23
28.5
17.6
23
28.5
33
45
53
65
80

0.16
0.22
0.3
0.46
0.64
0.85
1.15
1.45
1.9
2.6
3.6
5
6.5
8.6
11.4
14.8
17
22
27
17
22
27
31.5
43
52
62
76

GPS1MS/HAB
GPS1MS/HAB
GPS1MS/HAC
GPS1MS/HAD
GPS1MS/HAE
GPS1MS/HAE
GPS1MS/HAE
GPS1MS/HAF
GPS1MS/HAF
GPS1MS/HAG
GPS1MS/HAH
GPS1MS/HAH
GPS1MS/HAJ
GPS1MHAK
GPS1MHAK
GPS1MHAL
GPS1MHAM
GPS1MHAN
GPS1MHAP
GPS1MHAR
GPS2MHAN
GPS2MHAP
GPS2MHAR
GPS2MHAS
GPS2MHAT
GPS2MHAU
FDN36MC080GD
FDN36MC080GD
FDN36MC100GD

Rated
Magnetic
Magnetic
current setting Im
current
In
Pick-up band
20% Im
(A)
(A)
(A)
0.25
3.2
0.25
3.2
0.4
5.2
0.63
8.2
1
13
1
13
1
13
1.6
20.5
1.6
20.5
2.5
32.5
4
52
4
52
6.3
82
10
130
10
130
13
169
16
208
20
260
25
325
32
416
20
260
25
325
32
416
40
520
50
650
63
820
80
800 - 1200
1000
80
800 - 1200
1000
100
1000 - 1500
1200

CONTACTOR

OVERLOAD RELAY

Series

Series

Setting
range

CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL00
CL01
CL25
CL25
CL25
CL25
CL25
CL25
CL25
CL25
CL04
CL04
CL04
CL04
CL45
CL06
CL06
CL07
CL09
CL09
CL10

RT1B
RT1B
RT1C
RT1D
RT1D
RT1F
RT1F
RT1G
RT1H
RT1J
RT1K
RT1K
RT1L
RT1M
RT1N
RT1P
RT1S
RT1S
RT1U
RT1V
RT1S
RT1U
RT1V
RT2E
RT2G
RT2G
RT2H
RT2J
RT2J

0.16-0.26
0.16-0.26
0.25-0.41
0.4-0.65
0.4-0.65
0.65-1.1
0.65-1.1
1.0-1.5
1.3-1.9
1.8-2.7
2.5-4
2.5-4
4.0-6.3
5.5-8.5
8.0-12
10-16
14.5-18
14.5-18
21-26
25-32
14.5-18
21-26
25-32
30-43
42-55
42-55
54 65
64 82
64 82

Smallest
Min
wire Cu
frontal
(PVC) (2)
safety
380/415V clearance
2
(mm )
(mm)
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1
20
1.5
20
2.5
20
2.5
20
2.5
20
4
20
6
20
2.5
20
4
20
6
20
6/10
25
10
25
16
25
16
30
25
30
25
30

Surion
Surion GPS-B and Record Plus: Coordination Type 2 65kA at 380/400V and 415V
MOTOR
Rated
power

Ie
380/400V
(A)
0.9
1.25
1.6
2

(kW)
0.25
0.37
0.55
0.75

MOTOR PROTECTION CIRCUITBREAKER


Ie

Cat. no.

CONTACTOR

THERMAL RELAY

Setting
range In

Magnetic
setting Im

Series

Class 10

415V
0.8
1.1
1.5
1.9

GPS1BHAE
GPS1BHAF
GPS1BHAF
GPS1BHAG

(A)
0.63-1
1-1.6
1-1.6
1.6-2.5

(A)
13
20.5
20.5
32.5

(A)
CL00
CL00
CL00
CL00

Integrated into the motor protection circuit breaker


Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker

2.6
3.5
5

2.5
3.45
4.7

GPS1BHAH
GPS1BHAH
GPS1BHAJ

2.5-4
2.5-4
4-6.3

52
52
82

CL25
CL25
CL25

Integrated into the motor protection circuit breaker


Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker

3
4
5.5
7.5
11

7
9
12
16
22.5

6.5
8
11
14
21

GPS1BHAK
GPS1BHAK
GPS1BHAL
GPS1BHAM
GPS1BHAP

6.3-10
6.3-10
9.0-13
11.0-16
19-25

130
130
169
208
325

CL25
CL25
CL25
CL25
CL25

Integrated into the motor protection circuit breaker


Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker

15
18.5

30
37

28
35

GPS1BHAR
GPS2BHAS

24-32
28-40

416
520

CL04
CL45

Integrated into the motor protection circuit breaker


Integrated into the motor protection circuit breaker

22
30

44
60

41
55

GPS2BHAT
GPS2BHAU

25-50
45-63

650
820

CL06
CL07

Integrated into the motor protection circuit breaker


Integrated into the motor protection circuit breaker

37
45

72.5
85

65
79

FDH36MC080
FDH36MC100

80
100

950
1140

CL08
CL09

RT2J (64-82A)
RT2L (78-97A)

Surion GPS-B and Record Plus: Coordination Type 2 80kA at 380/400V and 415V
MOTOR
Rated
power
(kW)
0.25
0.37
0.55
0.75

Ie
380/400V
(A)
0.9
1.25
1.6
2

MOTOR PROTECTION CIRCUITBREAKER


Ie

Cat. no.

CONTACTOR

THERMAL RELAY
Class 10

Setting
range In

Magnetic
setting Im

Series

(A)
13
20.5
20.5
32.5

(A)
CL00
CL00
CL00
CL00

Integrated into the motor protection circuit breaker


Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker

0.8
1.1
1.5
1.9

GPS1BHAE
GPS1BHAF
GPS1BHAF
GPS1BHAG

A
B
C

415V
(A)
0.63-1
1-1.6
1-1.6
1.6-2.5

Technical data

1.1
1.5
2.2

1.1
1.5
2.2

2.6
3.5
5

2.5
3.45
4.7

GPS1BHAH
GPS1BHAH
GPS1BHAJ

2.5-4
2.5-4
4-6.3

52
52
82

CL25
CL25
CL25

Integrated into the motor protection circuit breaker


Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker

3
4
5.5
7.5
11

7
9
12
16
22.5

6.5
8
11
14
21

GPS1BHAK
GPS1BHAK
GPS1BHAL
FDH36MC020
FDH36MC030

6.3-10
6.3-10
9.0-13
20
30

130
130
169
210
300

CL25
CL25
CL05
CL04
CL45

Integrated into the motor protection circuit breaker


Integrated into the motor protection circuit breaker
Integrated into the motor protection circuit breaker
RT1S (14.5-18A)
RT1U (21-26A)

15
18.5

30
37

28
35

FDH36MC030
FDH36MC050

30
50

450
500

CL45
CL45

RT1V (25-32A)
RT1W (30-40A)

22
30

44
66

41
55

FDH36MC050
FDH36MC080

50
80

580
800

CL06
CL07

RT2G (42-55A)
RT2H (54-65A)

37
45

72.5
85

65
79

FDH36MC080
FDH36MC100

80
100

950
1140

CL08
CL09

RT2J (64-82A)
RT2L (78-97A)

(1) Current are relevant to four pole motors not having special characteristics of torque. Inrush currents: H 8 time rated current for H 1s.
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30C max. in free air and are selected to withstand the maximum let-through
energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.

D
E
F
G
H
I
X

D.11

Surion
Record Plus: Coordination Type 2 150kA at 380/400V and 415V
MOTOR (1)
Rated
power

THERMAL-MAGNETIC CIRCUIT BREAKER

Rated current

Cat. no. (3)




Manual motorstarter

A
B
C
D
E
F
G
H
I
X

D.12

(kW)
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132

380/400V 415V
(A)
16
14
22.5
21
30
28
37
35
44
40
60
55
72
68
85
80
105
100
138
135
170
165
211
200
245
240

FD*36TD016ED
FD*36TD025ED
FD*36TD032ED
FD*36TD040ED
FD*36TD050ED
FD*36TD063ED
FD*36TD080GD
FD*36TD100GD
FD*36TD125GD
FD*36TD160GD
FE*36TD200KF
FE*36TD250KF
FE*36TD250KF

Magnetic
setting Im
pick-up
band
20% Im

Magnetic
current

(A)
160
250
320
400
500
630
800
1000
1250
1280
1000 2000
1250 2500
1250 2500

(A)
160
250
320
400
500
630
800
1000
1250
1280
1700
2100
2500

(Class 10 protection)
CONTACTOR

Thermal
setting
range

Thermal
setpoint
(400V)

(A)
12.8 - 16
20 25
26 32
32 40
40 50
50 63
64 80
80 100
100 125
128 160
160 200
200 250
200 - 250

(A)
16
22.5
30
37
40
55
68
80
100
135
165
200
240

Series

Setpoint

CL45
CL45
CL45
CL45
CL06
CL07
CL08
CL09
CL10
CK75
CK08
CK85
CK09

Smallest
wire
Cu
(PVC) (2)
380/415V

Min
frontal
safety
clearance

(mm2)
2.5
4
6
10
10
16
25
35
35
50
70
95
120

(mm)
20
20
20
20
25
25
25
30
30
40
40
40
40

(*) Max Iq rating in kA: type N = 50 kA, type H = 80 kA, type L = 150 kA.
(1) Current are relevant to four pole motors not having special characteristics of torque.
Inrush currents: H 8 times rated current for H 1s (Normal starting) or H 5s (Heavy starting).
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30C max. in free air and are selected to withstand the maximum let-through
energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.
(3) Foreseen values for E-frame.

Surion
Record Plus: Coordination Type 2 Up to 150kA at 380/400V and 415V
MOTOR (1)
Rated
power

ONLY MAGNETIC CIRCUIT BREAKER

Rated current

Cat. no. (3)




FD*36MC012ED
FD*36MC012ED
FD*36MC020ED
FD*36MC020ED
FD*36MC030ED
FD*36MC030ED
FD*36MC050ED
FD*36MC050ED
FD*36MC050ED
FD*36MC080GD
FD*36MC080GD
FD*36MC100GD
FD*36MC100GD
FE*36MC160JF
FE*36MC160JF
FE*36MC250KF
FE*36MC250KF
FE*36MC250KF

Magnetic
current

(A)
125 - 188
125 - 188
200 - 300
200 - 300
300 - 450
300 - 450
500 - 750
500 - 750
500 - 750
800 - 1200
800 - 1200
1000 - 1500
1000 - 1500
1600 - 2400
1600 - 2400
2500 - 3750
2500 - 3750
2500 - 3750

(A)
120
150
200
210
450
500
500
540
580
800
950
1140
1400
1400
1900
2500
2800
3150

OVERLOAD RELAY

Series

Series

CL04
CL04
CL04
CL04
CL45
CL45
CL45
CL06
CL06
CL07
CL08
CL09
CL10
CL10
CK75
CK08
CK85
CK09

RT1N
RT1P
RT1P
RT1S
RT1U
RT1V
RT1W
RT2E
RT2G
RT2H
RT2J
RT2L
RT2M
RT2M
RT3E
RT3F
RT4P
RT4P

Setting
range

Smallest
wire
Cu
(PVC) (2)
380/415V

Min
frontal
safety
clearance

(A)
8 - 12
10 - 16
10 - 16
14.5 - 18
21 - 26
25 - 32
30 - 40
30 - 43
42 - 55
54 - 65
64 - 82
78 - 97
90 - 110
90 - 110
110 - 140
140 - 190
175 - 280
175 - 280

(mm2)
1.5
2.5
2.5
2.5
4
6
10
10
10
16
25
35
35
35
50
70
95
120

(mm)
20
20
20
20
20
20
20
25
25
25
25
30
30
30
40
40
40
40

Setpoint

Record Plus: Coordination Type 2 Up to 150kA at 380/400V and 415V


MOTOR (1)
Rated
power

ONLY MAGNETIC CIRCUIT BREAKER

Rated current

Cat. no. (3)





(kW)
2.2
3
4
5.5
7.5
7.5
11
15
18.5
22
22
30
37
45
55
55
75
90
110
132

380/400V 415V
(A)
5
4.5
7
6.5
9
8
12
11
14
16
22.5
21
30
28
37
35
40
44
60
55
72
68
85
80
100
105
138
135
170
165
211
200
245
240

FD*36MC008ED
FD*36MC008ED
FD*36MC012ED
FD*36MCa012ED
FD*36MC020EaD
FD*36MC020ED
FD*36MC030ED
FD*36MC030ED
FD*36MC050ED
FD*36MC050ED
FD*36MC050ED
FD*36MC080GD
FD*36MC080GD
FD*36MC100GD
FD*36MC100GD
FE*36MC160JF
FE*36MC160JF
FE*36MC250KF
FE*36MC250KF
FE*36MC250KF

Magnetic
setting Im
pick-up
band
20% Im

Magnetic
current

(A)
80 - 120
80 - 120
125 - 188
125 - 188
200 - 300
200 - 300
300 - 450
300 - 450
500 - 750
500 - 750
500 - 750
800 - 1200
800 - 1200
1000 - 1500
1000 - 1500
1600 - 2400
1600 - 2400
2500 - 3750
2500 - 3750
2500 - 3750

(A)
80
90
120
150
200
210
450
500
500
540
580
800
950
1140
1400
1400
1900
2500
2800
3150

CONTACTOR
Series

(Class 30 protection)

OVERLOAD RELAY
Series

Setting
range

Smallest
wire
Cu
(PVC) (2)
380/415V

Min
frontal
safety
clearance

(A)
4 - 6.5
5.5 - 8.5
7.5 - 11
10 - 16
10 - 16
12.5 - 20
17 - 27
26 - 40
26 - 40
32 - 52
32 - 52
45 - 70
60 - 90
60 - 90
80 - 125
80 - 125
120 - 190
120 - 190
200 - 310
200 - 310

(mm2)
1.5
1.5
1.5
2.5
2.5
2.5
4
6
10
10
10
16
25
35
35
35
50
70
95
120

(mm)
20
20
20
20
20
20
20
20
25
25
25
25
25
30
30
30
40a
40
40
40

Setpoint

CL25
CL04
CL04
CL45
CL45
CL45
CL45
CL45
CL06
CL06
CL06
CL07
CL08
CL09
CL10
CL10
CK75
CK08
CK85
CK09

Technical data

380/400V 415V
(A)
9
8
12
11
14
16
22.5
21
30
28
37
35
40
44
60
55
72
68
85
80
100
105
138
135
170
165
211
200
245
240

(kW)
4
5.5
7.5
7.5
11
15
18.5
22
22
30
37
45
55
55
75
90
110
132

Magnetic
setting Im
pick-up
band
20% Im

CONTACTOR

(Class 10 protection)

RT4LB
RT4LC
RT4aLD
RT4LE
RT4LE
RT4LF
RT4LG
RT4LH
RT4LH
RT4LJ
RT4LJ
RT4LK
RT4LL
RT4LL
RT4LM
RT4LM
RT4LN
RT4LN
RT4LR
RT4LR

B
C
D
E
F
G
H

(*) Max Iq rating in kA: type N = 50 kA, type H = 80 kA, type L = 150 kA.
(1) Current are relevant to four pole motors not having special characteristics of torque.
Inrush currents: H 8 times rated current for H 1s (Normal starting) or H 5s (Heavy starting).
(2) The minimum cycle cross-sections are referred to an ambient temperature of 30C max. in free air and are selected to withstand the maximum let-through
energy and the motor rated current. Besides the user has to consider the drop voltage, the type of laying and ambient temperature.
(3) Foreseen values for E-frame.

I
X

D.13

Surion
Dimensional drawings

Manual motorstarter

Fuseless starter - GPS1 rocker + Minicontactor MC

A
B

MC...A

MC...C

C
Fuseless starter - GPS1 rocker + Contactor CL00-CL01-CL02

D
E
F
G
H
I
X
CL00A-CL01A-CL02A

D.14

CL00D-CL01D-CL02D

Surion

Fuseless starter - GPS1 rocker + Contactor CL25

Dimensions
A
CL25A

CL25D

B
C

Fuseless starter - GPS2 + Contactor CL03-CL04

D
E
F
G
H
I
X
CL03A-CL04A

CL03D-CL04D

D.15

Surion
Dimensional drawings

Manual motorstarter

Fuseless starter - GPS2 + Contactor CL45

A
B
CL45A

CL45D

C
Fuseless starter - GPS2 + Contactor CL06-CL08

D
E
F
G
H
I
X
CL06A-CL08A

D.16

Surion

Fuseless starter - Record Plus + Contactor CL09 + Thermal overload relay RT2

Dimensions
A
B
C
D
E
F
G
H
I
X

D.17

Series M, CL, CK
Direct-on-line starters

Motorstarters

Series M
6 to 12A (AC-3)
Power circuit: up to 690V AC
Control circuit: up to 600V AC
Polycarbonate enclosure (IP40 - IP65)
- Shock resistance
- Total insulation
- 4 knock-out input holes PG13.5
- Cable entry in the base
Terminals protected against accidental contact
16 setting ranges from 0.11 up to 14A
Start contact block
Order codes ! page D.19
Wiring diagrams ! page D.24
Dimensions ! page D.32

Series CL
9 to 40A (AC-3)

Power circuit: up to 690V AC


Control circuit: up to 690V AC
IP00 version
Polycarbonate enclosure (IP40 - IP65)
- Shock resistance
- Total insulation
- 4 knock-out input holes
Empty enclosures version
Start contact block

B
C
D
E

Order codes ! page D.19


Wiring diagrams ! page D.25
Dimensions ! page D.32

Series CK
150 to 825A (AC-3)

G
Power circuit: up to 1000V AC
Control circuit: up to 690V AC
Protection degree IP00
Terminals protected against accidental contact: IP20
- KG75 to KG12: Coil and auxiliary terminals with built-in protection

Main terminals protector on request
- KG13: Coil and auxiliary terminals with built-in protection

H
I
X
Order codes ! page D.19
Wiring diagrams ! page D.26
Dimensions ! page D.33

D.18

Series M, CL, CK
Series M - Direct-on-line starters
Empty boxes

Laterally mounted to the contactor, allowing the electrical operation


the box push-button which incises on it.

MAGL110AT

100608

Series CL - Direct-on-line starters


Empty boxes

Neutral terminal


For use with
Push-buttons
Protection
Cat. no.
Ref. no Pack

degree

CL00, CL01,CL02
Start/Stop + Reset
IP40

LG0004P1B0
209344 1



IP65

LG0006P1B0
200004 1


Without push-buttons
IP40

LG0004S1B0
209347 1



IP65

LG0006S1B0
116011 1


Only Reset
IP40

LG0004R1B0
116651 1



IP65

LG0006R1B0
116652 1

CL25
Start/Stop + Reset
IP40

LG2504P1B0
100885 1



IP65

LG2506P1B0
101095 1


Only Reset
IP40

LG2504R1B0
116226 1



IP65

LG2506R1B0
133611 1

CL04
Start/Stop + Reset
IP40

LG0404P1B0
116653 1



IP65

LG0406P1B0
116656 1


Only Reset
IP40

LG0404R1B0
133264 1



IP65

LG0406R1B0
133265 1

CL25, CL04
Without push-buttons
IP40

LG0404S1B0
116996 1



IP65

LG0406S1B0
116997 1

BNL

104797

10

Direct-on-line starters

Start contact block


Push-buttons
Protection
Cat. no.
Ref. no Pack

degree



Start/Stop + Reset
IP40

MG0004PAT0
209780 1



IP65

MG0006PAT0
209781 1


Reset only
IP40

MG0004RAT0
137567 1



IP65

MG0006RAT0
116402 1


Start/Emergency stop
IP40

MG0004QAT0
137566 1



IP65

MG0006QAT0
116074 1

A
B
C

Conversion to permanent
control

Pressure-fixed between push-buttons in direct-on-line enclosures


for mechanical interlocking into permanent control.

EPL

104798

10

D
E

Start contact block

Pressure-fixed onto the front of direct-on-line starters allowing electrical


operation using the start push-button on the enclosure

BMLF

104800

10

F
G

Series CK - Direct-on-line starters. IP00


Connection sets

Plate

H
Cat. no.

Ref. no. Pack


Busbar set for power circuit

CK85,CK09,CK95
CK10,CK11
CK12

KVP85G
KVP10G
KVP12G

104770
104771
104767

1
1
1

Metallic plate

CK85, CK09, CK95


CK10, CK11
CK12

PVP85G
PVP10G
PCP12G

241747
241748
241749

1
1
1

D.19

Series M, CL, CK
Reversing starters

Motorstarters

Series M
6 to 12A (AC-3)
Power circuit: up to 690V AC
Control circuit: up to 600V AC

up to 250V DC
Assembled versions on request.
Screw and push-on terminals protected against accidental contact.
Protection degree IP20 in accordance with EN 60529.
Facility to mount instant and timed auxiliary contact blocks and voltage
suppressor blocks.

Order codes ! page D.21


Wiring diagrams ! page D.28
Dimensions ! page D.34

Series CL
9 to 105A (AC-3)

Power circuit: up to 690V AC


Control circuit: up to 690V AC
Protection degree IP00

B
C
D
E

Order codes ! page D.21


Wiring diagrams ! page D.28
Dimensions ! page D.34

Series CK
150 to 825A (AC-3)

Power circuit: up to 1000V AC


Control circuit: up to 690V AC
Protection degree IP00

H
I
X
Order codes ! page D.21
Wiring diagrams ! page D.29
Dimensions ! page D.35

D.20

Series M, CL, CK
Series M and CL - Reversing starters
Description

Wiring kits
for reversing
starters

Plate

Suitable to be usd with link


modules
Upper and lower connections
without overload relays

Metallic plate

Cat. no.

Ref. no.

Pack.

ac/dc
ac/dc
ac/dc
ac/dc
ac/dc
ac

WKMIU
WKLI02P
WKLI25P
WKLI04P
WKLI45P
WKLI07P

101421
101422
101423
101424
101425
101426

1
1
1
1
1
1

WKI0910
WKI0608

241751
241752

1
1

For use with


contactor
CK75, CK08
CK85, CK09, CK95
CK10, CK11
CK12
CK75, CK08
CK85, CK09, CK95
CK10, CK11
CK12

Cat. no.

Ref. no.

Pack.

KVP75U
KVP85U
KVP10U
KVP12U
KVP75I
KVP85I
KVP10I
KVP12I

113627
113628
133374
113630
133370
113631
133371
113633

1
1
1
1
1
1
1
1

CK75, CK08
CK85, CK95
CK10, CK11
CK12

KVB75I
KVB95I
KVB10I
KVB12I

104690
104691
104692
104693

1
1
1
1

CL06, CL07, CL08


CL08, CL09, CL10

Series CK - Reversing starters. IP00


Description

Connection sets

Busbar set for power circuit

Busbar set for power circuit


For assembly
with thermal overload relay.

Plate

Metallic plate

Reversing starters

ac/dc

For use with


contactor
MC0.., MC1.., MC2..
CL00.., CL01.., CL02..
CL25..
CL03.., CL04...
CL45..
CL06A.., CL07A.

A
B
C
D
E
F
G
H
I
X

D.21

Series CL, CK
Star-delta starters
Series CL

Motorstarters

Power circuit: up to 690V AC


Control circuit: up to 690V AC
Protection degree IP00
Use delay setting by electronic relay NMET
Terminals protected against accidental contact

Order codes ! page D.23


Wiring diagrams ! page D.30
Dimensions ! page D.37

Series CK
Power circuit: up to 1000V AC
Control circuit: up to 690V AC
Protection degree IP00
Protection against accidental contacts: IP20
- KE75:
Built-in protection
- KE08 - KE12: Coil and auxiliary terminals with built-in protection

Main terminals protector on request
- KE13:
Coil and auxiliary terminals with built-in protection

A
B
C
D
E
F
G
H
I
X

D.22

Order codes ! page D.23


Wiring diagrams ! page D.30
Dimensions ! page D.37

Series CL, CK
Series CL - Star-delta starters

Busbar sets for power


circuit

Plate











Metallic plate


Line-delta
Cat. no.
Ref. no. Pack
contactor
CL00
CL01, CL02
CL25

WKLE00
WKLE02
WKLE25

103238
103241
103243

1
1
1

CL06, CL07, CL08


CL09, CL10

WLSD
WLSD1

103247
241750

1
1

Busbar sets for power


circuit

Plate















Metallic plate




Line-delta
contactor

Star
Cat. no.
Ref. no. Pack
contactor

CK75, CK08
CK75, CK08
CK85, CK09, CK95
CK75, CK08
CK95
CK85, CK09, CK95
CK10, CK11
CK85, CK09, CK95
CK10, CK11
CK10, CK11
CK12
CK10, CK11
CK75, CK08

CK85, CK95

CK10, CK11

CK12

KVP75E
KVP08E
KVP85E
KVP95E
KVP10E
KVP12E

133378
116212
133379
113637
133380
116235

1
1
1
1
1
1

KVB75E
KVB95E
KVB10E
KVB12E

104694
104695
104597
104587

1
1
1
1

Star-delta starters

Series CK - Star-delta starters. IP00


A
B
C
D
E
F
G
H
I
X

D.23

Series M, CL
Wiring diagrams
Series M. Direct-on-line starter with
reset
Control circuit

Power circuit
Three phase

Motorstarters

Use of two phases


(single phase)

Control by two or more push-buttons

Series M. Direct-on-line starter with


start/emergency stop push-button
Power circuit

B
C
D
E
F
G
H
I
X

D.24

Use of two phases


(single phase)

Control circuit
Three phase

Control by two or more push-buttons

Series M, CL
Series CL. Direct-on-line starter
Control circuit

Power circuit

Control by two or more push-buttons

(float, thermostat, pressure switch, ...)

Series CL. Direct-on-line starter


with reset push-button
Power circuit
Single phase

Control circuit

Direct-on-line starters

Control by permanent contact

Control by two or more push-buttons

Three phase

(connection K1-95 must be removed)

Control by permanent contact

C
(float, thermostat, pressure switch, ...)

Series CL. Direct-on-line starter


with start/stop/reset push-button
Control circuit

Power circuit
Single phase

D
E

Control by two or more push-buttons

Three phase

G
(connection 95-13 must be removed)

Control by permanent contact

I
(float, thermostat, pressure switch, ...)

D.25

Series CK
Wiring diagrams
Series CK. Direct-on-line starter
Power circuit

CK75 ... CK12

Control by permanent contact

(float, thermostat, pressure switch, ...)

CK13

A
B
C
D
E
F
G
H
I
X

D.26

Control by two or more push-buttons

Three phase

Motorstarters

Use of two phases


(single phase)

Control circuit

Series CK
Notes
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

Direct-on-line starters

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

A
B
C
D
E
F
G
H
I
X

D.27

Series M, CL, CK
Wiring diagrams
Series M. Reversing starter without
thermal overload relay
Control circuit

Control by two or more push-buttons

Motorstarters

Power circuit

A
B

Series CL. Reversing starter without


thermal overload relay
Power circuit

Control circuit

Control by two or more push-buttons

C
D
E
F
G

Series CL. Reversing starter with


thermal overload relay
Power circuit

H
I
X

D.28

Control circuit

Control by two or more push-buttons

Series CK
Series CK. Reversing starter
without thermal overload relay
Power circuit

Control circuit
CK75 ... CK12

CK13

Reversing starters

Control by two or more push-buttons

A
B
C

Series CK. Direct-on-line starters


with thermal overload relay
Power circuit

Control circuit
CK75 ... CK12

CK13

E
F
G
H
Control by two or more push-buttons

I
X

D.29

Series CL, CK
Wiring diagrams
Series CL and CK. Star-delta starters

Motorstarters

Power circuit

A
B
C
D
E
F
G
H
I
X

D.30

Control circuit

Series CL, CK
Notes
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

Star-delta starters

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

A
B
C
D
E
F
G
H
I
X

D.31

Series M, CL, CK
Dimensional drawings
Direct-on-line starters. IP40 / IP65
Series CL

Series M

Motorstarters

.
.

A
B
C
D

LG00... - LG02...
87
180
124.5
162
20
49
8
21
21
21
21

A
B
C
D
E
F
G
H
J
K
L

Series CL - Direct-on-line starters


CL00 ... CL25

CL04

F
G
H

CL45 ... CL08

CL09 ... CL10

I
.

D.32

LG25... - LG04...
101
195
136
177
23
57
8
23
21
23
23

Series M, CL, CK

Series CK - Direct-on-line starters


CK75 ... CK08

CK85 ... CK95

Direct-on-line starters

A
CK10 ... CK11

CK12

B
C
D
E
F
G
H
I
X

D.33

Series M, CL, CK
Dimensional drawings
Series M. Direct-on-line reversing starters
MC_C

MC_C

MC_A

Motorstarters

MC_A

A
B
C

Series CL. Direct-on-line reversing starters without thermal overload relay




A
CL00... - CL25... 130
CL03... - CL45... 150

B
C
116 87.5
136 100.5

D
81
87



A
CL06... - CL08... 171
CL09... - CL10... 186

5.5
5.5

B
135
150

C
160
167

D
155
155

E
133
133

D
E
F
G
H
I
X

D.34

Series CL. Direct-on-line reversing starters with thermal overload relay




A
CL00... - CL25... 130
CL03... - CL45... 150

B
C
116 110.5
136 103.5

D
81
87

E
135
145

5.5
5.5



A
CL06... - CL08... 171
CL09... - CL10... 186

B
135
150

C
160
167

D
155
155

E
133
133

F
205
258

Series M, CL, CK

Series CK. Direct-on-line reversing starters without thermal overload relay


CK75 .... CK08

Reversing starters

CK85 .... CK95

A
Series CK. Direct-on-line reversing starters with thermal overload relay

CK75 .... CK08

C
D
E

F
CK85 .... CK95

G
H
I
X

D.35

Series CL, CK
Dimensional drawings
Series CK - Direct-on-line reversing starters without thermal overload relay

Motorstarters

CK10 .... CK11

CK12

A
B
C

Series CK - Direct-on-line reversing starters with thermal overload relay


CK10 .... CK11

D
E
F
G
H
I
X

D.36

CK12

Series CL, CK



A
CL00... - CL25... 190
CL03... - CL04... 220

B
C
D
180 110.5 135
210 103.5 145



CL06... - CL08...
CL09...
CL10...

B
217
247
247

A
253
263
283

C
129
138
151

D
205
247
247

E
155
155
155

F
133
133
133

D.O.L. reversing/Star-delta starters

Series CL - Star-delta starters

A
B
Series CK - Star-delta starters
CK75 ... CK08

C
.

D
E
F

CK85 ... CK95

G
H
I
X

D.37

Series M, CL, CK
Dimensional drawings
Series CK - Star-delta starters

Motorstarters

CK10 ... CK11

A
B
C
D
E
F
G
H
I
X

D.38

CK12

Series M, CL, CK
Utilisation categories
according to IEC 60947-4-1

Making and breaking capacity


IEC 60947-4-1

Standard utilisation categories AC

Values given for closing and opening by intermittent use

Category

AC-1


AC-2


AC-3


AC-4

AC-5 a
AC-5 b
AC-6 a
AC-6 b
AC-7 a
AC-7 b
AC-8 a

AC-8 b

Cat.

Standard utilisation categories DC


Category

DC-1


DC-3


DC-5


DC-6

Typical applications
Non-inductive or slightly inductive loads.
Resistance furnaces
Shunt motors:
starting, plugging, inching
Series motors:
starting, plugging, inching
Incandescent lamps

Rated

Closing (3)

Ic/Ie Ur/Ue cos(4) Ic/Ie

Opening

current

Ur/Ue cos (4)

AC-1

All
values

1.5

1.05

0.80

1.5

1.05

0.80

AC-2

All
values

1.05

0.65

1.05

0.65

AC-3 Ie 100A

10

1.05

0.45

1.05

0.45

0.35

Ie > 100A

10

1.05

0.35

1.05

AC-4 Ie 100A

12

1.05

0.45

10

1.05

0.45

12

1.05

0.35

10

1.05

0.35

Ie > 100A


Cat.

Rated

Closing

Opening


current
Ic/Ie Ur/Ue L/R(5) Ic/Ie Ur/Ue L/R(5)

(ms)
(ms)
DC-1

All
values

1.5

1.05

1.5

1.05

DC-3

All
values

1.05

2.5

1.05

2.5

DC-5

All
values

1.05

15

1.05

15

Electrical endurance

Applications

Typical applications
Non-inductive or slightly loads.
Resistance furnaces
Slip-ring motors:
starting, plugging
Squirrel-cage motors (1):
starting, switching off motors during running.
Squirrel-cage motors:
starting, plugging, inching.
Discharge lamps
Incandescent lamps
Transformers
Cos capacitors
Slightly inductive loads for domestic applications
Motors in domestic applications
Drive motors for cooling compressors (2) with
manual reset and thermal overload relay
Drive motors for cooling compressors (2) with
manual reset and automatic reset

A
B

IEC 60947-4-1

Values given for closing and opening intermittent use


Cat. Rated Closing (3)
Opening

current

Ic/Ie

AC-1

All
values

Ur/Ue cos(4) Ic/Ie


1

0.95

Ur/Ue cos(4)
1

0.95

AC-2

All
values

2.5

0.65

2.5

0.65

AC-3 Ie 17A

0.65

0.17

0.65

0.35

0.17

0.35

Ie > 17A

AC-4 Ie 17A

0.65

0.65

0.35

0.35

Ie > 17A

D
E
F


Cat.

Rated


current
Ic/Ie

(1) Category AC-3 can be used for accidental not continuous short
period service, while mounting and testing machines. The number
of operations shall not be greater than 5 per minute or 10 per 10
minutes.
(2) The drive motor of a hermetic cooling compressor is an assembly of
a motor and compressor in the same housing, without any axle; the
motor is working in the cooling liquid.
(3) Making conditions in alternating current are expressed by effective
value. Moreover the asymmetrical current high value, referred to
cos , can assume a higher value.
(4) Tolerance for cos = 0.05
(5) Tolerance for L/R = 15%

Closing
Ur/Ue L/R(5) Ic/Ie
(ms)

Opening
Ur/Ue L/R(5)
(ms)

DC-1

All
values

DC-3

All
values

2.5

2.5

DC-5

All
values

2.5

7.5

2.5

7.5

Ue
Ie
Ur
Ic

Rated operational voltage


Rated operational current
Feed-back voltage
Current made or broken

G
H
I
X

D.39

Series M, CL, CK
Utilisation category AC-1

Motorstarters

Three pole contactors

A
B
C
D
E
F
G
H
I
X

D.40

Type MC0 MC1


Max. operat. current 40C
(A) 20
20
at ambient temp. of 55C
(A) 20
20
(for all voltages)
70C
(A) 16
16
Max. operat. power
230/220V (kW) 7.5
7.5
Three-phase
400/380V (kW) 13
13
resistors
440/415V (kW) 15
15

500V
(kW) 17
17

690/660V (kW) 22.5 22.5
Cable size
(mm2) 2.5
2.5
Percentage of the max. 120 ops./h (%) 100 100
operational current at 300 ops./h (%) 100 100

600 ops./h (%) 100 100

1200 ops./h (%) 100 100

3000 ops./h (%) 50
50

MC2
20
20
16
7.5
13
13
17
22.5
2.5
100
100
100
100
50

CL00
25
25
20
9.5
16.5
18
21.5
28.5
4
100
100
100
100
50

CL01
25
25
20
9.5
16.5
18
21.5
28.5
4
100
100
100
100
50

CL02 CL25 CL03


32
45
45
32
45
45
25
32
32
12
17
17
22
29
29
23
32
32
27.5 39
39
38
51
51
6
10
10
100 100 100
100 100 100
100 100 100
100 100 100
50
50
50

CL04
60
60
48
22.5
39.5
43
52
68.5
16
100
100
100
100
50

CL45
60
60
48
22.5
39.5
43
52
68.5
16
100
100
100
100
50

CL06 CL07 CL08 CL09 CL10


90
110 110 140 140
90
110 110 140 140
72
88
88
110 110
30
42
42
53
53
55 72.5 72.5
92
92
57
79
79
100 100
69
95
95
121 121
95
125 125 160 160
35
35
35
50
50
100 100 100 100 100
100 100 100 100 100
100 100 100 100 100
100 100 100
80
80
50
50
50
40
40

Type CK75C CK08C CK85B CK09B CK95B CK10C CK11C CK12B CK13B
Max. operat. current 40C
(A) 250 250 315 315 450 600 700 1000 1250
at ambient temp. of: 55C
(A) 200 200 252 252 382 510 546 736 1125
(for all voltages)
70C
(A) 155 155 195 195 300 402 468 680 1060
Max. operat. power 230/220V
(kW) 90
90
114 114 170 191 234 289 450
Three-phase
400/380V
(kW) 155 155 196 196 310 329 406 500 780
resistors
440/415V
(kW) 180 180 227 227 343 329 470 578 904

500V
(kW) 200 200 259 259 389 415 533 657 1027

690/660V
(kW) 270 270 341 341 537 572 705 867 1354

1000V
(kW) 400 400 517 517 780 866 1060 1314 2054
Cable size
(mm2) 120 120 185 185
2x
2x
2x
2x
2x

(30X5) (30X8) (30X8) (30X10) (30X10)
Percentage of the max. 120 ops./h (%) 100 100 100 100 100 100 100 100 100
operational current at 300 ops./h (%) 100 100 100 100 100 100 100 100
90

600 ops./h (%) 100 100 100 100 100
80
80
80
70

1200 ops./h (%) 80
80
80
80
80





3000 ops./h (%) 40
40
40
40




Four pole contactors


Type
Max. operat. current 40C
(A)
at ambient temp. of: 55C
(A)
(for all voltages)
70C
(A)
Max. operat. power 230/220V
(kW)
Three-phase
400/380V
(kW)
resistors
440/415V
(kW)

500V
(kW)

690/660V
(kW)
Cable size
(mm2)
Percentage of the max. 120 ops./h
(%)
operational current at 300 ops./h
(%)

600 ops./h
(%)

1200 ops./h
(%)

3000 ops./h
(%)

MC0
20
20
16
7.5
13
15
17
22.5
2.5
100
100
100
100
50

MC1
20
20
16
7.5
13
15
17
22.5
2.5
100
100
100
100
50

MC2
20
20
16
7.5
13
15
17
22.5
2.5
100
100
100
100
50

CL01
25
25
20
9.5
16.5
18
21.5
28.5
4
100
100
100
100
50

Type
CK07B CK08B CK09B CK95B
Max. operat. current 40C
(A)
200
325
400
500
at ambient temp. of: 55C
(A)
170
260
320
425
(for all voltages)
70C
(A)
140
201
272
335
Max. operat. power 230/220V
(kW)
76
123
152
191
Three-phase
400/380V
(kW)
131
214
263
329
resistors
440/415V
(kW)
143
233
287
359

500V
(kW)
173
281
346
415

690/660V
(kW)
228
371
457
572

1000V
(kW)

562
692
866
Cable size
(mm2)
95
185
2x
2x

(25X5) (30X5)
Percentage of the max. 120 ops./h
(%)
100
100
100
100
operational current at 300 ops./h
(%)
100
100
100
100

600 ops./h
(%)
100
100
100
100

1200 ops./h
(%)
80
80
80
80

3000 ops./h
(%)
40
40
40
40
Increase in maximum operational current
through connection poles in parallel:
2 poles in parallel: Ie x 1.8
3 poles in parallel: Ie x 2.4
4 poles in parallel: Ie x 3.2

CL02
32
32
25
12
22
23
27.5
38
6
100
100
100
100
50

CL03
45
45
32
17
29
32
39
51
10
100
100
100
100
50

CK10C
600
510
402
228
395
431
519
686
1039
2x
(30X8)
100
100
80

CK11C
700
546
468
266
460
503
606
800
1212
2x
(30X8)
100
100
80

CL04
60
60
48
22.5
39.5
43
52
68.5
16
100
100
100
100
50

CL05
90
90
72
30
55
57
69
95
35
100
100
100
100
50

CL07
110
110
88
42
72.5
79
95
125
35
100
100
100
100
50

CL08(1) CL09(2)
110
140
110
140
88
110
42
53
72.5
92
79
100
95
121
25
160
35
50
100
100
100
100
100
100
100
80
50
40

CK12B CK13B
1000
1250
736
1125
680
1060
381
476
658
822
719
898
866
1082
1143
1428
1732
2165
2x
2x
(30X10) (40X10)
100
100
100
90
80
70




(1) Only types (2NO + 2NC)
(2) Only types (4NO)

Series M, CL, CK
Utilisation category AC-3
Three pole contactors
MC0
6

MC1
9

MC2 CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL06 CL07 CL08 CL09 CL10
12
9
12
18
25
25
32
40
50
65
80
95
105

1.5
2
2.2
3
2.2
3
3
4
3
4
100
100
100
100
35

3
4
4
5.5
4
5.5
4
5.5
4
5.5
100
100
100
100
35

3
4
5.5
7.3
5.5
7.3
5.5
7.3
5.5
7.3
100
100
100
100
35

Type
Operational current Ie
(A)
for Ue 400V
Max. operat. power 230/220V
(kW)
Three-phase motors
(HP)
50/60Hz
400/380V
(kW)

(HP)

440/415V
(kW)

(HP)

500V
(kW)

(HP)

690/660V
(kW)

(HP)

1000V
(kW)

(HP)
Percentage of the max. 120 ops./h (%)
operational current
300 ops./h (%)

600 ops./h (%)

1200 ops./h (%)

3000 ops./h (%)

2.2
3
4
5.5
4
5.5
5.5
7.5
5.5
7.5
100
100
100
100
35

3
4
5.5
7.5
5.5
7.5
7.5
10
7.5
10
100
100
100
100
35

4
5.5
7.5
10
7.5
10
10
13.5
10
13.5
100
100
100
100
35

7.5
10
12
16
12
16
15
20
15
20
100
100
100
100
35

7.5
10
12
16
12
16
15
20
15
20
100
100
100
100
35

9
12
16
22
16
22
18.5
25
18.5
25
100
100
100
100
35

11
15
18.5
25
22
30
25
34
30
40
100
100
100
100
35

15
20
22
30
25
34
30
40
35
48
100
100
100
100
35

18.5
25
30
40
37
50
40
55
45
60
100
100
100
100
35

22
30
37
50
45
60
45
60
45
60
100
100
100
100
35

25
34
45
60
50
68
55
75
55
75
100
100
100
75
25

30
40
55
75
55
75
65
88
65
88
100
100
100
75
25

CK75C CK08C CK85B CK09B CK95B CK10C CK11C CK12B CK13B


150 185 205 250 309 420 550 700 825
45
60
75
100
80
108
100
135
100
135
65
88
100
100
100
75
25

55
75
90
125
100
135
110
150
132
180
100
135
100
100
100
75
25

65
88
110
150
125
170
132
180
155
205
110
150
100
100
100
75
25

75
100
132
180
132
180
160
220
200
270
150
205
100
100
100
75
25

90
125
160
220
185
250
200
270
250
335
200
270
100
100
100
75

125
170
220
300
230
312
300
405
375
510
300
405
100
100
75

160
220
280
380
315
425
400
540
450
610
375
510
100
100
75

220
300
375
510
400
540
480
650
500
680
450
610
100
100
75

250
340
450
610
450
610
500
680
550
750
500
680
100
80
65

A
B
C
D

Utilisation category AC-4

Three pole contactors


Type
Operational current Ue 690V
(A)
Operational power
230/220V
(kW)
(200.000 operations)
(HP)

400/380V
(kW)

(HP)

500V
(kW)

(HP)

690/660V
(kW)

(HP)
Max. operational current 400V
(A)
(35.000 operations)
Max. operational power 400/380V
(kW)

Applications

Types
Operational current Ie
(A)
for Ue 400V
Max. operat. power 230/220V (kW)
Three-phase motors
(HP)
50/60Hz
400/380V (kW)

(HP)

440/415V (kW)

(HP)

500V
(kW)

(HP)

690/660V (kW)

(HP)
Percentage of the max. 120 ops./h (%)
operational current at 300 ops./h (%)

600 ops./h (%)

1200 ops./h (%)

3000 ops./h (%)

MC0
2.75
0.55
0.73
1.1
1.5
1.5
2
2.2
3
6

MC1
3.5
0.75
1
1.5
2
2.2
3
3
4
9

2.2

MC2 CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL06 CL07 CL08 CL09 CL10
3.5
5
7
8
12
12
16
18.5
23
30
37
44
50
0.75 1.1
1.5
1.8
3
3
3.7
4
5.5
7.5
10
11
13
1
1.5
2
2.4
4
4
5
5.3
7.3
9.7
13
14.6 17.3
1.5
2.2
3
3.7
5.5
5.5
7.5
9
11
15
18.5
22
25
2
3
4
5
7.3
7.3
9.7
12
14.6
20
24.6 29.2
33
2.2
3
4
5.5
7.5
7.5
10
11
15
18.5
22
25
30
3
4
5.3
7.3
9.7
9.7
13
14.6
20
24.6 29.2
33
40
3
4
5.5
7.5
10
10
11
15
18.5
22
25
30
37
4
5.3
7.3
9.7
13
13
14.6
20
24.6 29.2
33
40
49
9
9
12
18
25
25
32
40
50
65
80
95
105
4

5.5

7.5

11

12

16

Type CK75C CK08C CK85B CK09B CK95B CK10C CK11C CK12B CK13B
Operational current Ue 400V
(A) 65
75
90
110 125 150 165 250 350
Operational power
230/220V
(kW) 18.5
22
25
33
37
45
50
80
110
Three-phase motors
(HP) 24.6 29.2
33
44
49
60
66.5 106 146
50/60Hz
400/380V
(kW) 33
40
45
55
63
80
90
132 165
(200.000 operations)
(HP) 44
53
60
73
83.8 106 119 175 219

500V
(kW) 45
50
63
75
90
100 110 225 250

(HP) 60
66.5 83.8 100 119 133 146 300 332

690/660V
(kW) 55
63
80
100 110 132 150 250 315

(HP) 73
83.8 106 133 146 175 200 332 419
Max. operational current 400V
(A) 150 185 205 250 309 420 550 700 825
(35.000 operations)
Max. operational power 400/380V
(kW) 75
90
110 132 160 220 280 375 450

18.5

22

30

37

45

F
G
H

55

I
X

D.41

Series M, CL, CK
Electrical endurance
Category AC1

Motorstarters

Number of
operations

Currrent Ic = Ie
all voltages

Category AC2

B
C
D
E
F

Number of
operations

Current
Ic = 2.5 Ie
(Ue 400V)

H
I
X

D.42

Rated motor power


(Ic = 2.5 Ie)

Series M, CL, CK

Category AC3

Number of
operations

Rated motor power


(Ic = Ie)

Applications

Current
Ic = Ie
(Ue 400V)

A
B
C

Category AC4

D
Number of
operations

E
F
G

Current
Ic = 6 Ie
(Ue 400V)

Rated motor power


(Ic = 6 Ie)

I
X

D.43

Series M, CL, CK

Motorstarters

Electrical endurance

A
B
C
D
E
F
G
H
I
X

D.44

Mixed category AC2 / AC2

Mixed category AC4 / AC3

Graph to determine the coefficient which when multiplied


by the contactor electrical endurance in category AC2, will
give the electrical endurance in mixed category AC2/AC2.

Electrical endurance for mixed category (AC3/


AC4) is calculated with the following formula:

Example:
% of operations in AC2:
35% (or 65% as AC2)
Breaking current Ic = 2.54 Ie
Contactor considered: CK08BA
Resultant coefficient from the graph: 0.35
Electrical endurance in AC2 for contactor
CK085A , to drive a motor of 45kW at 380V:
le = 85A; 5.5 x 106operations.
Resultant electrical endurance for mixed service
considered:
0.35 x 5.5 x 106 = 1.92 x 106 operations.

Electrical
endurance
(AC3/AC4) =

Electrical endurance (AC3)


1 +

% ops. AC4
100

Electr. endur. (AC3) _


1
Electr. endur. (AC4)

Series M, CL, CK
Notes
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

Applications

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

A
B
C
D
E
F
G
H
I
X

D.45

Series M, CL, CK
Series M and CL. Max. operational current Ie (A) - DC utilisation categories
Category DC1. L/R H 1ms

Motorstarters

Ue


24V




48V



60V



125V



220V



440V



600V


Poles
in serie

MC0

MC1

MC2

CL00

CL01

CL02

CL25

CL03

CL04

CL45

CL05

CL06

CL07

CL08

CL09

CL10

1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

6
8
15
15
5
8
12
15
4
6
12
15
1.6
4
5
5
0.2
1.7
4
4
0.09
0.26
0.5
0.5
-
-
-
-

9
12
20
20
7.5
12
16
20
6
9
16
20
2.5
6
10
10
0.36
2.6
8
8
0.13
0.4
1
1
-
-
-
-

9
12
20
20
7.5
12
16
20
6
9
16
20
2.5
6
10
10
0.36
2.6
8
8
0.13
0.4
1
1
-
-
-
-

18
25
25
-
15
25
25
-
12
25
25
-
6
18
25
-
0.8
7.5
25
-
0.4
0.8
8
-
-
0.4
4
-

18
25
25
25
15
25
25
25
12
25
25
25
6
18
25
25
0.8
7.5
25
25
0.4
0.8
8
15
-
0.4
4
8

18
32
32
32
15
32
32
32
12
32
32
32
6
18
25
32
0.8
7.5
25
32
0.4
0.8
8
15
-
0.4
4
10

25
45
45
-
20
45
45
-
18
45
45
-
8
25
32
-
0.8
7.5
32
-
0.4
0.8
10
-
-
0.4
5
-

25
45
45
45
20
45
45
45
18
45
45
45
8
25
45
45
1
8
45
45
0.5
1
10
20
-
0.5
5
12

32
60
60
60
25
60
60
60
18
60
60
60
8
45
60
60
1
8
50
60
0.5
1
10
25
-
0.5
5
12

40
60
60
-
35
60
60
-
32
60
60
-
8
45
60
-
1
8
50
-
0.5
1
10
-
-
0.5
5
-

50
90
90
90
45
90
90
90
40
90
90
90
16
80
90
90
2
20
90
90
0.8
2
15
80
-
1
7.5
50

50
90
90
-
45
90
90
-
40
90
90
-
16
80
90
-
2
20
90
-
0.8
2
15
-
-
1
7.5
-

65
110
110
110
55
110
110
110
50
110
110
110
16
90
110
110
2
20
110
110
0.8
2
15
90
-
1
7.5
65

65
110
110
-
55
110
110
-
50
110
110
-
16
90
110
-
2
20
110
-
0.8
2
15
-
-
1
7.5
-

80
140
140
140
70
140
140
140
65
140
140
140
16
110
140
140
2
20
140
140
0.8
2
15
110
-
1
7.5
75

80
140
140
70
140
140
65
140
140
16
110
140
2
20
140
0.8
2
15
1
7.5
-

Category DC3. L/R H 2.5ms

Ue

Poles
in serie

MC0

MC1

MC2

CL00

CL01

CL02

CL25

CL03

CL04

CL45

CL05

CL06

CL07

CL08

CL09

CL10

1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

-
4
8
-
-
3
6
-
-
3
6
-
-
0.85
1.7
-
-
0.35
0.7
-
-
0.05
0.13
-
-
-
-
-

-
9
12
-
-
6
9
-
-
6
9
-
-
4.5
6
-
-
1.2
2.5
-
-
0.15
0.3
-
-
-
-
-

-
9
12
-
-
6
9
-
-
6
9
-
-
4.5
6
-
-
1.2
2.5
-
-
0.15
0.3
-
-
-
-
-

12
18
18
-
9
18
18
-
7.5
18
18
-
2
10
15
-
0.6
2
12
-
-
0.3
1.5
-
-
-
0.8
-

12
18
18
18
9
18
18
18
7.5
18
18
18
2
10
15
15
0.6
2
12
15
-
0.3
1.5
6
-
-
0.8
2.5

12
18
18
18
9
18
18
18
7.5
18
18
18
2
12
18
18
0.6
2
12
18
-
0.3
1.5
6
-
-
0.8
2.5

18
25
25
-
12
25
25
-
10
25
25
-
2
18
25
-
0.6
2
18
-
-
0.3
1.5
-
-
-
0.8
-

18
25
25
25
12
25
25
25
10
25
25
25
3
18
25
25
0.6
2
18
32
-
0.5
3
6
-
-
1.5
2.5

25
40
40
40
18
40
40
40
15
40
40
40
3
25
32
32
0.6
2
25
32
-
0.5
3
6
-
-
1.5
2.5

32
40
40
-
20
40
40
-
15
40
40
-
3
32
40
-
0.6
2
32
-
-
0.5
3
-
-
-
1.5
-

40
65
65
65
30
65
65
65
25
65
65
65
3
50
35
35
0.8
7
50
65
-
1
3
50
-
-
1.5
25

40
65
65
-
30
65
65
-
25
65
65
-
3
50
35
-
0.8
7
50
-
-
1
3
-
-
-
1.5
-

50
80
80
80
35
80
80
80
30
80
80
80
3
60
80
80
0.8
7
65
80
-
1
3
65
-
-
1.5
30

50
80
80
-
35
80
80
-
30
80
80
-
3
60
80
-
0.8
7
65
-
-
1
3
-
-
-
1.5
-

65
105
105
105
45
105
105
105
35
105
105
105
3
80
105
105
0.8
7
95
105
-
1
3
75
-
-
1.5
35

65
105
105
45
105
105
35
105
105
3
80
105
0.8
7
95
1
3
1.5
-

CL08

CL09

CL10

50
80
80
-
35
80
80
-
30
80
80
-
1.2
60
70
-
0.5
3
7
-
-
-
1
-
-
-
-
-

65
105
105
105
45
105
105
105
35
105
105
105
1.2
85
95
105
0.5
4
7
95
-
-
1
60
-
-
-
30

65
105
105
45
105
105
35
105
105
1.2
85
95
0.5
4
7
1
-


24V



48V



60V



125V



220V



440V



600V


Ue

Poles
in serie

MC0

MC1

MC2

CL00

CL01

CL02

CL25

CL03

CL04

CL45

CL05

CL06

CL07

24V



48V



60V



125V



220V



440V



600V


1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

-
3
6
-
-
2.5
6.5
-
-
2
5
-
-
0.65
1.3
-
-
0.16
0.5
-
-
-
0.4
-
-
-
-
-

-
4.5
9
-
-
4
8
-
-
3
7
-
-
1.5
2
-
-
0.26
0.8
-
-
-
0.1
-
-
-
-
-

-
4.5
9
-
-
4
8
-
-
3
7
-
-
1.5
2
-
-
0.26
0.8
-
-
-
1.1
-
-
-
-
-

12
18
18
-
9
18
18
-
7.5
18
18
-
0.8
5
15
-
-
0.8
3
-
-
-
0.5
-
-
-
-
-

12
18
18
18
9
18
18
18
7.5
18
18
18
0.8
5
15
15
-
0.8
3
10
-
-
0.5
2
-
-
-
0.75

12
18
18
18
9
18
18
18
7.5
18
18
18
0.8
5
15
18
-
0.8
3
10
-
-
0.5
2
-
-
-
0.75

18
25
25
-
12
25
25
-
10
25
25
-
0.8
5
20
-
-
0.8
3
-
-
-
0.5
-
-
-
-
-

18
25
25
25
12
25
25
25
10
25
25
25
1.2
5
20
25
-
0.8
3
15
-
-
0.7
4
-
-
-
2.5

25
40
40
40
18
40
40
40
15
40
40
40
1.2
5
25
32
-
0.8
3
15
-
-
0.7
4
-
-
-
2.5

32
40
40
-
20
40
40
-
15
40
40
-
1.2
5
32
-
-
0.8
3
-
-
-
0.7
-
-
-
-
-

40
65
65
65
30
65
65
65
25
65
65
65
1.2
50
60
65
0.5
3
7
65
-
-
1
40
-
-
-
20

40
65
65
-
30
65
65
-
25
65
65
-
1.2
50
60
-
0.5
3
7
-
-
-
1
-
-
-
-
-

50
80
80
80
35
80
80
80
30
80
80
80
1.2
60
70
80
0.5
3
7
75
-
-
1
50
-
-
-
25

B
C
D
E

Category DC5. L/R H 15ms

H
I
X

D.46

Series M, CL, CK
Max. operational current Ie (A) - DC utilisation categories (continued)
Category DC1. L/R H 1ms

Poles
in serie

CK07

CK75

CK08

CK85

CK09

CK95

CK10

CK11

CK12

CK13

24V



48V



60V



125V



220V



440V



600V


1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

150
200
200
200
125
140
200
200
100
140
200
200
20
110
200
200
-
65
200
200
-
-
60
110
-
-
32
85

200
250
250
-
170
175
250
-
140
175
250
-
25
200
250
-
-
110
250
-
-
-
120
-
-
-
65
-

200
250
250
250
170
175
250
250
140
175
250
250
25
200
250
250
-
110
250
250
-
-
120
200
-
-
65
100

250
315
315
-
200
220
315
-
175
220
315
-
30
250
315
-
-
150
315
-
-
-
150
-
-
-
80
-

250
315
315
315
200
220
315
315
175
220
315
315
30
250
315
315
-
150
315
315
-
-
150
250
-
-
80
130

350
450
450
450
295
315
500
500
245
315
500
500
50
300
500
500
-
200
500
500
-
-
180
315
-
-
95
170

500
600
600
600
425
425
600
600
350
425
600
600
60
400
600
600
-
250
600
600
-
-
240
400
-
-
130
215

600
700
700
700
500
480
700
700
420
480
700
700
70
500
700
700
-
250
700
700
-
-
300
500
-
-
160
265

800
1000
1000
1000
600
700
1000
1000
560
700
1000
1000
100
600
1000
1000
-
300
1000
1000
-
-
400
700
-
-
215
375

1000
1250
1250
1250
850
850
1250
1250
700
850
1250
1250
125
1000
1250
1250
400
1250
1250
480
800
250
430

Applications

Ue

Category DC3. L/R H 2.5ms


Ue

Poles
in serie

CK07

CK75

CK08

CK85

CK09

CK95

CK10

CK11

CK12

CK13

24V



48V



60V



125V



220V



440V



600V


1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

105
105
105
105
70
105
105
105
55
105
105
105
20
105
105
105
-
10
105
105
-
-
8
80
-
-
4
40

150
150
150
-
105
150
150
-
85
150
150
-
25
150
150
-
-
60
150
-
-
-
50
-
-
-
25
-

185
185
185
185
130
185
185
185
105
185
185
185
25
185
185
185
-
70
185
185
-
-
55
105
-
-
25
50

205
205
205
-
140
205
205
-
110
205
205
-
30
205
205
-
-
80
205
-
-
-
65
-
-
-
30
-

250
250
250
250
175
250
250
250
140
250
250
250
30
250
250
250
-
85
250
250
-
-
70
185
-
-
35
90

309
309
309
309
215
309
309
309
175
309
309
309
50
309
309
309
-
95
309
309
-
-
80
205
-
-
40
100

420
420
420
420
290
420
420
420
230
420
420
420
60
420
420
420
-
140
420
420
-
-
120
250
-
-
60
125

550
550
550
550
385
550
550
550
300
550
550
550
70
550
550
550
-
185
550
550
-
-
150
300
-
-
75
150

700
700
700
700
490
700
700
700
390
700
700
700
100
700
700
700
-
225
700
700
-
-
180
400
-
-
90
200

825
825
825
825
575
825
825
825
460
825
825
825
125
825
825
825
400
825
825
320
700
165
350

A
B
C
D
E
F

Category DC5. L/R H 15ms


Ue

Poles
in serie

CK07

CK75

CK08

CK85

CK09

CK95

CK10

CK11

CK12

CK13

24V



48V



60V



125V



220V



440V



600V


1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4

105
105
105
105
60
105
105
105
55
105
105
105
15
80
105
105
-
8
80
105
-
-
5
65
-
-
40
35

150
150
150
-
90
150
150
-
85
150
150
-
20
95
150
-
-
50
95
-
-
-
40
-
-
-
45
-

185
185
185
185
110
185
185
185
105
185
185
185
20
105
185
185
-
55
105
185
-
-
40
95
-
-
50
45

205
205
205
-
120
205
205
-
110
205
205
-
25
150
205
-
-
65
150
-
-
-
50
-
-
-
75
-

250
250
250
250
150
250
250
250
140
250
250
250
25
185
250
250
-
70
185
250
-
-
50
150
-
-
90
75

309
309
309
309
185
309
309
309
175
309
309
309
40
205
309
309
-
80
205
309
-
-
60
185
-
-
100
90

420
420
420
420
250
420
420
420
230
420
420
420
50
250
420
420
-
120
250
420
-
-
90
205
-
-
125
100

550
550
550
550
330
550
550
550
300
550
550
550
60
300
550
550
-
150
300
550
-
-
100
250
-
-
150
125

700
700
700
700
420
700
700
700
390
700
700
700
80
400
700
700
-
180
400
700
-
-
100
300
-
-
200
150

825
825
825
825
495
825
825
825
460
825
825
825
100
700
825
825
320
700
825
200
400
350
200

G
H
I
X

D.47

Series M, CL, CK
Direct-on-line starters
Motors connected directly on-line with a contactor and a
thermal overload relay.
Symple installation with high starting torque and
current.
For use with motors of medium power that do not need
a progressive star

Torque-speed curve

F
G
H
I
X

D.48

Motor torque

Resisting torque

Current-speed curve

Current

Ic = Ie
Ic = 6 Ie

Current

Switching off motors during running


Switching off motors during starting

Torque

Motorstarters


AC-3
AC-4

Speed

Diagram

Speed

Series M, CL, CK

Selection table
Motor

230/200V
kW
A



0.39

0.58


0.76
1.05
1.4

2

2.75
3.5
5
7





9


12



0.06
0.09


0.12
0.18
0.25
0.37
0.55
0.75

1.1
1.5

2.2

3
3.7
4


5.5



0.39
0.58


0.76
1.05
1.4
2
2.75
3.5

5
7

9

12
14
16


21

0.06

0.09
0.12
0.18

0.25
0.37
0.55
0.75
1.1
1.5

2.2

3.7
4

5.5

7.5



11

0.23

0.34
0.44
0.61

0.78
1.13
1.6
2
2.6
3.5

5

8
9

12

16



22.5

440/415V
kW
A


0.06 0.21


0.09 0.31
0.12 0.4


0.18 0.56


0.25 0.7
0.37 1.1


0.55 1.5
0.75
2
1.1 2.5


1.5 3.4
2.2 4.5






3
6.5
3.7 7.3
4
8






5.5
11

500V
kW
A


0.06 0.17


0.09 0.26
0.12 0.33
0.18 0.46
0.25 0.6


0.37 0.9
0.55 1.2


0.75 1.5
1.1
2
1.5 2.6


2.2 3.8
3
5






3.7
6
4
6.5






5.5
9

0.06 0.21 0.06



0.09
0.09 0.31 0.12
0.12 0.4 0.18
0.18 0.56 0.25



0.25 0.7 0.37
0.37 1.1 0.55
0.55 1.5 0.75
0.75 2
1.1
1.1 2.5 1.5
1.5 3.4 2.2



2.2 4.5

3.7 7.3 3.7



4
9
5.5



5.5 11 7.5
7.5 14



10





11
11
21
13


15

0.17
0.26
0.33
0.46
0.6

0.9
1.2
1.5
2
2.6
3.8


6

9

12

15.5

17
20
23

Fuse
Contactor Thermal

690/660V
1000V
kW
A kW
A
0.06 0.13


MC0
0.09 0.2


0.12 0.25


0.18 0.35






0.25 0.46






0.37 0.7


0.55 0.9


0.75 1.1






1.1 1.5


1.5
2






2.2 2.9


3
3.5










3.7 4.6


MC1
4
5


















5.5 6.7

MC2








0.09 0.2
0.12 0.25
0.18 0.35
0.25 0.46


0.37 0.7
0.55 0.9
0.75 1.1
1.1 1.5
1.5
2
2.2 2.9


3.7 4.6


5.5
7




7.5
9






11
13
13
16




CL00

















CL01


CL02


CL25


relay
MT03A
MT03B
MT03B
MT03C
MT03C
MT03D
MT03D
MT03E
MT03E
MT03F
MT03G
MT03H
MT03I
MT03J
MT03J
MT03K
MT03L
MT03M
MT03L
MT03L
MT03M
MT03M
MT03N
MT03N
MT03M
MT03N
MT03P

aM
A
0.5
0.5
0.5
1
1
1
1
2
2
2
2
4
4
4
4
6
10
10
10
10
10
10
12
12
12
16
16

gG-gL
A
1
1
1
2
2
2
2
4
4
4
4
6
6
6
6
10
16
16
16
16
16
16
20
20
20
20
20

RT1B
RT1C
RT1C
RT1D
RT1D
RT1F
RT1F
RT1G
RT1H
RT1J
RT1K
RT1K
RT1L
RT1L
RT1M
RT1M
RT1N
RT1N
RT1P
RT1P
RT1S
RT1P
RT1S
RT1T
RT1U

2
2
2
2
2
2
2
2
2
4
4
6
6
6
10
12
16
16
16
20
20
20
20
32
32

4
4
4
4
4
4
4
4
6
6
6
10
16
16
20
25
25
25
35
40
40
40
40
50
50

Direct-on-line starters




0.06

0.09


0.12
0.18
0.25

0.37

0.56
0.75
1.1
1.5





2.2


3

400/380V
kW A


0.06 0.23


0.09 0.34


0.12 0.44
0.18 0.61


0.25 0.78
0.37 1.13


0.55 1.6
0.75 2
1.1 2.6


1.5 3.5
2.2
5






3
7


3.7
8
4
9




5.5 12

A
B
C
D
E
F
G
H
I
X

D.49

Series M, CL, CK
Direct-on-line starters
Selection table (continued)

Motorstarters

Motor

A
B
C
D
E
F
G
H
I
X

D.50

230/200V
kW
A


7.5 27










11
40




15
50






18.5 65




22
75






25
84
30 105

400/380V
kW A


15
30






18.5 37






22
44






30
60




37
72








45
85
55 105

440/415V
500V
690/660V
kW
A
kW
A
kW
A




17
20
15
28 17.5 26.5




18.5 23




22
25

18.5 28.5

18.5 35
22
33




25 37.5 30
35
22
40








33
38
25
45














37
41


30
45
40
43
30
55
37
55


37
66








45
49


45
65








45
80








55
60


50
73


50
88
55
80


55 100























37 126





75 138 75
45 150

























90 170 90
55 182


100














110


110 211























































150


150 283 160
90 309 160 309

(1) Separate mounting: type RT2xP.






135





165
182


200











269
285




75

90





110



132











185

200




105

129





156



188











261

281


75
90






110
132



150




160
185





220
250


80
97






118
141



166




170
193





230
262

Fuse
Contactor Thermal

1000V
kW
A


CL04






CL45










CL06






CL07








CL08








CL09






CL10
55






75
90




110



132
150


160
185
200
220
250



40
CK75






54
CK08
64




78
CK85



94
CK09
105


113
CK95
130
141
155
CK10
175

CK95


relay
RT1T
RT1V
RT1U
RT1V
RT1V
RT1W
RT1W
RT2E (1)
RT2E
RT2G
RT2G
RT2E
RT2G
RT2H
RT2J
RT2G
RT2J
RT2J
RT2L
RT2H
RT2J
RT2L
RT2M

aM
A
32
40
32
40
40
50
50
50
50
63
63
63
63
80
80
80
100
100
100
80
100
100
125

gG-gL
A
50
63
50
63
63
80
80
80
80
80
80
80
80
125
125
125
125
125
160
125
125
160
200

RT4J
RT3C
RT3D
RT3D
RT3E
RT3E
RT3F
RT4 K
RT3B
RT3E
RT3F
RT3F
RT3F
RT4L (1)
RT4N (1)
RT4P (1)
RT4P (1)
RT4M (1)
RT4M (1)
RT4N (1)
RT4P (1)
RT4M (1)
RT4N (1)
RT4N (1)
RT5A (1)
RT5A (1)
RT4P (1)
RT4R (1)
RT4R (1)
RT4R (1)

63
125
125
160
160
200
200
80
100
160
200
200
200
100
250
250
250
125
160
200
250
160
160
200
200
250
315
355
400
400

80
160
160
200
200
224
224
125
160
200
250
250
250
160
315
315
315
160
200
250
315
200
200
250
250
315
400
400
425
425

Series M, CL, CK

Selection table (continued)


Motor

230/200V
kW
A






110 356


















132 425




150 500
160 520














185 609
200 630
220 710












250 823

400/380V
kW A






185 355
220 370


220 408
















250 475


280 530












300 563
315 580
335 630
355 650
375 680






400 720
425 763
450 800

440/415V
kW
A


185 325


200 350
220 385
















250 437


280 480
300 508
315 530












335 565
355 600
375 630


400 673






425 714
450 756

500V
kW
A
220 310




250 348


280 385
300 409












315 426
335 456
355 485
375 513
400 543
















450 613
475 647






500 680





Contactor

690/660V
1000V
kW
A kW
A
280 292


CK10
300 307


315 322


335 344


355 366


375 390








280 197
CK11


300 211


315 221


335 234


355 245
400 412






425 442


450 462












375 256
CK12


400 273


425 290


450 307
475 488


500 514
























475 324
CK13


500 341















Fuse
Thermal
relay
RT5C
RT5C
RT5C
RT5D
RT5D
RT5D
RT5D
RT5B
RT5B
RT5B
RT5B
RT5B
RT5D
RT5D
RT5D
RT5E
RT5E
RT5E
RT5B
RT5C
RT5C
RT5C
RT5E
RT5E
RT5E
RT5E
RT5E
RT5E
RT5E
RT5C
RT5C
RT6A
RT6A
RT6A
RT6A

aM gG-gL
A
A
400
425
425
500
425
500
425
500
500
500
500
500
500
500
250
315
315
355
315
355
315
355
315
355
500
500
630
630
630
630
630
630
630
630
630
630
315
355
400
425
400
425
400
425
630
630
630
630
630
630
630
630
800
800
800
800
800
800
500
630
500
630
1000 1000
1000 1000
1000 1000
1000 1000

Direct-on-line starters

A
B
C
D
E
F
G
H
I
X

D.51

Series M, CL, CK
Star-delta starters

In order to use this type of starting, the following conditions


must be met:
The ends of the three stator windings should terminate in a
terminal box (6 terminals, see diagram).
The line voltage should be the same as the motor delta
connection voltage.

This starting system is suitable for machines where the


resisting torque during starting is less than 1/3 of the motor
torque (see torque speed curves).
The target of this type of starting is to reduce the current
during starting to 1/3, there by reducing the linedrop (see
current speed curves).
Reduce the motor torque to 1/3 to smooth out mechanical
stress on the machine and on the load (see torque speed
curves).

Torque-speed curve

Current-speed curve

Current

Current in

Torque

Motorstarters

For AC squirrel cage motors

Current in Y

B
C

2
1 Torque in
2 Torque in Y
3 Resisting torque

D
E
F
G
H
I
X

D.52

Diagram

Speed

Speed

Series M, CL, CK

Selection table

Motor
400/380V

440/415V

kW
2.2
3
3.7
4


5.5



7.5


11


15


18.5

22





30

37


40



45

kW
4
5.5

7.5


11



15


18.5

22
25

30



33

37
45

55






75



90

kW
A


5.5 11


7.5 14




11
21






15
28


18.5 35




22
40




30
55






37
66




45
80


55 100




75 135














90 165

gG-gL

RT1L
RT1M
RT1N
RT1N
RT1M
RT1N
RT1P
RT1P
RT1P
RT1P
RT1S
RT1S
RT1T
RT1U
RT1T
RT1U
RT1V
RT1U
RT1W
RT1W
RT1V
RT2G
RT1W
RT2E
RT2E
RT2G
RT2G
RT2H
RT2H
RT2J
RT2J
RT2H
RT2L
RT2J
RT2L
RT2J
RT2L
RT2L
RT2M

A
25
35
40
40
40
40
50
50
50
50
63
63
80
63
63
80
80
80
80
125
80
160
100
160
160
160
160
160
160
200
200
160
250
250
250
250
250
250
250









132 141


CK75C
CL08
RT3C
160
55 182




132 188




CK75C
CL08
RT3D
200




110 200






CK75C
CL08
RT3D
250








150 166


CK75C
CL09
RT3D
200








160 170


CK75C
CL10
RT3D
200


110 211


150 218




CK75C
CL10
RT3E
250




132 240 160 228




CK75C
CL10
RT3E
250
75 239










CK75C
CL10
RT3E
250










90
64
CK75C CK75C
RT4LJ
80










110 78
CK75C CK75C
RT4LJ
108


132 245








CK75C
CL10
RT3F
315








185 193


CK75C CK75C
RT3E
250


150 288 150 269 185 261




CK08C CK75C
RT3F
315




160 285






CK08C CK75C
RT3F
315








200 207


CK08C CK75C
RT3E
250








220 230


CK08C CK75C
RT3E
250
90 309










CK08C CK75C
RT3F
315
For electrical endurance see page C.34-44, but first divide the rated power and current values shown in the table by 1.73.
The thermal overload relay should be set at 0.58 In of the motor.

200
250
315
250
250
315
315
315
125
160
355
315
355
355
315
315
355

kW






































Line and
Delta
CL00
CL00
CL00
CL01
CL01
CL01
CL02
CL02
CL02
CL25
CL25
CL25
CL25
CL25
CL03
CL03
CL04
CL45
CL45
CL45
CL45
CL06
CL06
CL06
CL06
CL06
CL07
CL07
CL08
CL08
CL08
CL09
CL09
CL09
CL09
CL10
CL10
CL10
CL10

Star

Fuse
A
16
16
20
20
20
20
32
32
32
32
40
40
50
50
50
63
63
50
63
80
63
100
80
100
100
100
100
125
125
160
160
125
160
160
160
160
160
200
200

kW
A
kW
A
5.5
9
7.5
9
7.5
12












11
13
11
17








15
18
15
23



18.5 23




18.5 28.5 22
26
22
33








30
35
30
45








37
41








37
55
45
49








45
65
55
60




55
80




75
80




75 105












90
97




90 129








110 118




110 156





1000V

Thermal

aM

A
9
12

16


22.5



30


37

44
50

60



65

72
85

105






138



170

690/660V

Contactors

relay

A
9
12
14
16


21



27


40


50


65

75





105

126


138



150

500V

CL00
CL00
CL00
CL00
CL00
CL00
CL01
CL01
CL01
CL02
CL02
CL02
CL02
CL25
CL25
CL25
CL03
CL03
CL03
CL03
CL03
CL04
CL04
CL04
CL04
CL04
CL06
CL06
CL06
CL06
CL06
CL06
CL07
CL07
CL07
CL07
CL07
CL08
CL08

Star-delta starters

230/200V

A
B
C
D
E
F
G
H
I
X

D.53

Series M, CL, CK
Star-delta starters
Selection table (continued)

Motorstarters


Motor

A
B
C
D
E
F
G
H
I
X

D.54

230/200V

400/380V

440/415V

kW




160


185

200
220











250







280
300
315











335
355






375
400

425

kW






185
200

220








250



280




300


315
355

355









375
375


400



400

425
450
475

kW







110

132












150





160




185










200








220


A







356

425












500





520




609










630








710


A




309


355

370
408











475







530
563
580











630
650






680
720

763

A






325
350

385








437



480




508


530
561

600









587
630


622



673

714
756
798

500V
kW




200
220



250
280









300
315





335
355
375












400
425
450


475



425
500
530
560

600

A




281
310



348
385









409
426





456
485
513












543
580
613


647



659
680
725
762

817

690/660V
kW




250



280





300
315
335


355
375




400
425
450












475
500
530
560


600
630




670
710
750

A




262



262





307
322
349


366
390




412
442
462












488
514
545
575


616
646




688
729
770

Contactors

1000V
kW
132
150
160
185







200
220
250



280





300
315









335
355
375
400
425
450








475
500
600





A
94
105
113
130







141
155
175



197





211
221









234
245
256
273
290
307








324
341
407





Line and
Delta
CK08C
CK08C
CK08C
CK85B
CK85B
CK85B
CK85B
CK85B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK95B
CK95B
CK95B
CK95B
CK95B
CK95B
CK95B
CK95B
CK95B
CK95B
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK11C
CK11C
CK11C
CK11C
CK11C

Star
CK75C
CK75C
CK75C
CK75C
CK75C
CK75C
CK75C
CK75C
CK75C
CK75C
CK08C
CK08C
CK08C
CK08C
CK08C
CK08C
CK08C
CK09B
CK08C
CK85B
CK85B
CK85B
CK85B
CK85B
CK85B
CK85B
CK85B
CK85B
CK85B
CK85B
CK85B
CK85B
CK85B
CK85B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK95B
CK95B
CK95B
CK95B
CK95B
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C

Thermal

MotorF
Fuse

relay

aM

gG-gL

RT4LK
RT3B
RT3B
RT4LL
RT4N
RT4N
RT4P
RT4P
RT4N
RT4P
RT4P
RT4LL
RT4LM
RT4LM
RT4N
RT4N
RT4P
RT4LM
RT4P
RT4P
RT4P
RT4P
RT4R
RT4LM
RT4LM
RT4R
RT4R
RT5C
RT4C
RT5C
RT5C
RT5C
RT5C
RT5C
RT5A
RT5A
RT5A
RT5A
RT5A
RT5A
RT5C
RT5C
RT5C
RT5C
RT5D
RT5D
RT5D
RT5D
RT5B
RT5B
RT5B
RT5D
RT5D
RT5D
RT5E
RT5E
RT5E

A
125
125
125
160
355
355
400
400
315
500
500
200
200
200
355
355
500
250
500
425
500
500
630
250
250
500
500
630
630
630
630
630
630
800
315
315
315
355
355
355
630
630
630
630
800
800
800
800
355
400
500
800
800
800
1000
1000
1000

A
160
160
160
200
400
400
425
425
355
500
500
250
250
250
400
400
500
315
500
500
500
500
630
315
315
500
500
630
630
630
630
630
630
800
355
355
355
400
400
400
630
630
630
630
800
800
800
800
400
425
500
800
800
800
1000
1000
1000

For electrical endurance see page C.34-44, but first divide the rated power and current values shown in the table by 1.73.
The thermal overload relay should be set at 0.58 In of the motor.

Series M, CL, CK

Selection table (continued)



Motor
230/200V
kW
A
250 823












280 910
300 975
315 1023
335 1083








355 1142




375 1206
400 1286
425 1364

400/380V
kW A






450 800
475 846


500 892
530 943


560 996








600 1074




630 1128
670 1200
710 1270


750 1342

440/415V
kW
A








500 840


530 890
560 941


600 1010
630 1058








710 1097


670 1125
710 1190
750 1255



500V
kW
A












630 857
670 912
710 965
750 1020






800 1088








850 1156





690/660V
kW
A










800 821
850 873










900 924
950 975















Contactors

1000V
Line and
kW
A
Delta


CK11C
630 428 CK11C
670 455 CK11C


CK11C


CK11C


CK11C


CK11C


CK11C


CK12C


CK12C


CK12C
750 510 CK12C


CK13B


CK13B


CK12B


CK12B
800 543 CK13B


CK12B


CK13B


CK13B


CK13B


CK13B

Thermal

Star

relay

CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK11C
CK11C
CK11C
CK11C
CK11C
CK11C
CK11C
CK11C
CK11C
CK12C
CK12C

RT5E
RT5B
RT5C
RT5E
RT5E
RT5E
RT5E
RT5E
RT5E
RT5E
RT5E
RT5C
RT6A
RT6A
RT5E
RT5E
RT5C
RT5E
RT6A
RT6A
RT6A
RT6A

Fuse
aM
A
1000
500
500
1000
1000
1000
1000
2x630
2x630
2x630
2x630
630
2x630
2x630
2x630
2x630
630
2x630
2x800
2x800
2x800
2x800

gG-gL
A
1000
630
630
1000
1000
1000
1000
2x630
2x630
2x630
2x630
630
2x630
2x630
2x630
2x630
800
2x630
2x800
2x800
2x800
2x800

Star-delta starters

For electrical endurance see page C.34-44, but first divide the rated power and current values shown in the table by 1.73.
The thermal overload relay should be set at 0.58 In of the motor.

B
C
D
E
F
G
H
I
X

D.55

Series M, CL, CK
Autotransformer starters

Motorstarters

For AC squirrel cage motors


This type of starting is used for machines where the
resisting torque during starting is less than the motor
torque (see torque speed curves):
Reduce current during starting to the required value
(this will depend on the autotransformer voltage ratio
selected).
Reduce motor torque to smooth out mechanical stress
on the machine and on the load (see torque speed
curves). Reduction of the motor will depend on the
autotransformer voltage ratio.
The two requirements for star-delta starting do not apply
here. That is to say both end of the three windings do not
have to be accessible and the line voltage does not have to
be the same as the delta connection voltage.

This system also has the following advantages over stardelta starting:
required current and starting torque can be selected.
starting can be effected at various points.
motor voltage continuity during network switching.

Torque-speed curve

Current-speed curve

Current

Torque

C
D
Speed

Speed

E
Diagram

F
G
H
I
X

D.56

Line
contactor

Primary
contactor

Star
contactor

Series M, CL, CK

Selection table

Motor

Contactors

400/380V
kW A
4
9


5.5 12


7.5 16




11 22.5




15
30






18.5 37


22
44






30
60








37
72


45
85


55 105

440/415V
kW
A
4
8


5.5 11
7.5 14






11
21




15
28




18.5 35
22
40










30
55
37
66








45
80
50
88


55 100

500V
690/660V
kW
A
kW
A
5.5
9




7.5
9
7.5
12






10 15,5



11
13
11
17


13
20




15
18
15
23







18.5 23
18.5 22.5 22
25
22
33








30
35








30
45




37
41
37
55








45
49


55
60
45
65






55
80








75
80
75 105




90
97

1000V
kW
A





























































75


90



110



132





160

220






250


315


335


425
450

75


90



110



132






185
220
250





280

300
335


375


450

90


110



132


150
160





220

280




300
315
335

375



450


500






90


110



150
160
220
250





280
335
355



375


450


500


138


170



211



245





309

408






475


580


630


762
800

135


165



200



240






325
385
437





480

508
565


630


756

129


156



188


218
228





310

285




409
426
456

513



613


800


110
132



150


160
185
200




220

300
335




400



450


475


500


118
141



166


170
193
207




230

307
344




412



462


488


514






64


78



105
113
155
175





197
234
245



256


307


341


Line

CL00
CL01
CL01
CL02
CL02
CL25
CL25
CL25
CL03
CL04
CL04
CL45
CL45
CL45
CL06
CL06
CL06
CL06
CL07
CL07
CL07
CL07
CL08
CL08
CL08
CL08
CL08
CL09
CL09
CL10
CL10

Pr. trafo
+ Star
CL00
CL00
CL00
CL00
CL00
CL01
CL01
CL01
CL01
CL01
CL02
CL02
CL02
CL02
CL03
CL03
CL03
CL03
CL03
CL04
CL04
CL04
CL04
CL04
CL06
CL06
CL06
CL06
CL06
CL06
CL07

CK75C
CK08C
CK08C
CK08C
CK08C
CK08C
CK85B
CK85B
CK85B
CK09B
CK09B
CK09B
CK09B
CK95B
CK10C
CK10C
CK95B
CK10C
CK10C
CK10C
CK11C
CK10C
CK11C
CK11C
CK11C
CK11C
CK11C
CK12B
CK12B
CK12B
CK12B
CK12B
CK12B
CK13B
CK13B
CK13B
CK13B

CL07
CL08
CL08
CL08
CL08
CL08
CL09A
CL09A
CK75C
CK75C
CK75C
CK75C
CK75C
CK08C
CK08C
CK85B
CK08C
CK08C
CK08C
CK85B
CK85B
CK09B
CK09B
CK09B
CK09B
CK09B
CK09B
CK95B
CK95B
CK95B
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C

Thermal
relay

Fuse

RT1N
RT1N
RT1P
RT1P
RT1S
RT1P
RT1S
RT1T
RT1T
RT1U
RT1V
RT1U
RT1U
RT1W
RT2E
RT2E
RT2G
RT2G
RT2G
RT2E
RT2H
RT2J
RT2G
RT2H
RT2J
RT2J
RT2L
RT2L
RT2L
RT2M
RT2M

aM
A
16
16
16
20
20
20
20
32
32
32
40
32
40
50
50
50
63
63
63
63
80
80
80
80
80
80
100
100
125
160
125

gG-gL
A
25
25
35
40
40
40
40
50
50
50
63
50
63
80
80
80
80
80
80
80
125
125
125
125
125
125
160
160
160
200
200

RT3E
RT3E
RT3F
RT3F
RT3F
RT3B
RT4N
RT4P
RT4N
RT4N
RT4P
RT4R
RT4M
RT4M
RT5A
RT5A
RT4P
RT5C
RT5C
RT5D
RT5D
RT5B
RT5B
RT5B
RT5D
RT5D
RT5E
RT5B
RT5E
RT5E
RT5C
RT5D
RT5E
RT5C
RT6A
RT6A
RT6A

200
160
200
200
200
100
250
250
100
200
250
315
160
160
200
250
315
400
425
425
630
250
315
315
500
630
630
315
630
630
400
630
800
500
800
1000
1000

224
200
250
250
250
160
315
315
160
250
315
355
200
200
250
315
355
425
500
500
630
315
355
355
500
630
630
355
630
630
425
630
800
630
800
1000
1000

Autotransformer starters

230/200V
kW
A
2.2
9


3
12
3.7 14






5.5 21




7.5 27






11
40




15
50






18.5 65






22
75


25
84


30 105



37 126




45 150
55 182












75 239










90 309


110 356
132 425










150 500




160 520




200 630




220 710
250 823

A
B
C
D
E
F
G
H
I
X

D.57

Series M, CL, CK
Contactors for rotor starters

Whatever the application, a distinction should be made


between the two electrical circuits which are used in this
type of starters:
Stator circuit, present in two categories and ahving a
different breaking current in each:
Category AC2: switching-off motors during running, Ic = Ie
Category AC 2: switching-off motors during starting,
Ic = 2.5 Ie
Rotor circuit, with similar characteristics to those in
category AC1.

Torque-speed curve

Current-speed curve

Current

This type of starter is used in machines with resisting


torque of any value where it is required to:
Start with reduced peak currents without consequent
motor torque reduction, as is the case with high resisting
torques and when starting with reduced peak currents is
required.
Control speed for different load or resisting torque
values, with reduced peak currents: lifting and transport
gear, flow volume control, etc.

Torque

Motorstarters

For AC slip-ring motors

B
C
Speed

Speed

D
Diagram

E
Stator contactor

Rotor contactors

F
End contactor

G
H
I
X

D.58

Intermediate contactors

Series M, CL, CK

Stator circuit

Rotor circuit

Motor power

Con- Thermal
tactor


Rotor

230V 400V 440V 500V 690V 1000V


220V 380V 415V





















































660V

kW

kW

kW

kW

kW

kW


5.5



7.5


11

15


18.5



22

25

30
37



45
55




75



90

110




132
150



220


220
250


11



15


18.5
22


30




37

45

55
75



90





132



160

200



220

250



335


425
450

11




15

18.5
22
25


30
37



45

50

55
75



90
100
110



132



160
185
220




250
250


300
375



450

13



15
17

22

25

30
37



45

55
63

75
90



110

132



160



220

250



300
315
335


375



450
500



15
17


18.5
33

33

40


45
55


75

90



110
132




160
200



220
300
315
335



400




475


500
























90





150



185
250




280
335
355



375
450


500


Contactor

relay

Current (1)

Max. voltage

28
37
42
48
55
60
75
90
98
112
120
135
147
165
180
187
202
240
247
280
315
360
390
472
525
585
660
825
945
1087
1188
1485
1956

1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500

Intermediate

End

CL00
CL00
CL00
CL01
CL02
CL02
CL25
CL25
CL03
CL04
CL45
CL45
CL06
CL06
CL06
CL07
CL07
CL08
CL08
CL09
CL09
CL10
CK75C
CK08C
CK85B
CK09B
CK95B
CK10C
CK10C
CK11C
CK11C
CK12B
CK13B

CL00
CL01
CL01
CL02
CL25
CL03
CL04
CL45
CL45
CL06
CL06
CL06
CL06
CL07
CL07
CL08
CL09
CL10
CK75C
CK75C
CK08C
CK85C
CK09B
CK95B
CK95B
CK10C
CK10C
CK11C
CK12B
CK12B
CK12B
CK13B

aM gG-gL
CL25
CL25
CL03
CL04
CL04
CL04
CL45
CL45
CL06
CL06
CL06
CL07
CL07
CL07
CL08
CL09
CL08
CL08
CL10
CL10
CK75C
CK75C
CK75C
CK08C
CK08C
CK08C
CK08C
CK08C
CK85B
CK09B
CK09B
CK09B
CK09B
CK95B
CK10C
CK10C
CK10C
CK10C
CK10C
CK10C
CK11C
CK11C
CK11C
CK11C
CK11C
CK12B
CK12B
CK12B
CK12B
CK13B
CK13B
CK13B
CK13B

RT1T
RT1U
RT1T
RT1T
RT1U
RT1V
RT1U
RT1W
RT2E
RT2G
RT2G
RT2G
RT2H
RT2J
RT2G
RT2H
RT2J
RT2J
RT2J
RT2L
RT3D
RT3D
RT3E
RT3B
RT3E
RT3F
RT3F
RT4N
RT4P
RT4M
RT4N
RT4P
RT4P
RT4N
RT4N
RT4P
RT5C
RT5C
RT5C
RT5B
RT5B
RT5B
RT5D
RT5D
RT5E
RT5B
RT5C
RT5E
RT5E
RT5C
RT6A
RT6A
RT6A

32
32
25
32
32
40
32
50
50
63
63
63
80
80
63
80
80
100
100
125
125
160
200
100
160
200
200
250
250
125
200
250
315
160
200
315
355
400
500
250
315
315
500
630
630
355
400
630
800
400
630
1000
1000

50
50
40
50
50
63
50
80
80
80
80
80
125
125
80
125
125
160
160
160
160
200
250
125
200
250
250
315
315
160
250
315
355
200
250
355
400
425
630
315
355
355
600
630
630
400
425
800
800
500
800
1000
1000

(1) The currents shown relate to the delta connection of the


contactors poles. If the poles are star-connected, divide the values
given in the column by 1.5.

Contactors for rotor starters

Fuse

A
B
C
D
E
F
G
H

Electrical endurance
Stator circuit (see graph AC-2)
!
Rotor circuit (see graph AC-1)
!

I
X

D.59

Series M, CL, CK
Contactors for rotor speed drives
Stator circuit

Rotor circuit

Motor power (1)


Contactor

Jogging
10% AC-2

2.4
3.7
5
7
9
10.5
13.5
18.5
21
22.5
27.5
38
40
50
55
70
85
105
124
140

4.5
6.5
8
13
16.5
19.5
23
28
34
39
49
65
75
85
96
110
147
181
215
250

5
7.5
10
15
19
24
27
32
40
47
55
70
85
90
110
115
175
220
235
260

5.5
7.5
10
15
19
24
27
32
40
47
55
70
85
90
110
115
175
220
235
260

5.5
8
10
15
19
24
27
32
40
47
55
75
85
100
110
125
175
220
257
300

6.3
9
11
15
19
27
30
35
45
50
60
75
95
100
120
125
195
233
270
280













80
95
110
120
165
220
250
276

CL00
CL01
CL02
CL25
CL04
CL45
CL06
CL07
CL08
CL09
CL10
CK75C
CK08C
CK85B
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B


Rotor
current

(2)



22

30

39

60

72

87

105

127

147

177

195

220

240

280

315

360

405

525

780

885

Jogging
20% AC-2

2.1
2.6
3.6
6.3
8
9.2
10.5
13
17.3
19.6
22
32
36
42
47.8
60
77
89
110
132

3.7
4.5
6.5
11
13.8
16
18.5
23
30
34
38
60
75
78
82.5
96
132
153
190
228

4.4
6.1
8.2
12.7
15.9
18.5
22
27
34.6
39
46
65
75
85
90
110
140
178
218
230

4.4
6.1
8.2
12.7
15.9
18.5
22
27
34.6
39
46
65
75
85
96
110
150
178
218
230

4.4
6.1
8.2
12.7
15.9
18.5
22
27
34.6
39
46
65
75
85
96
110
150
185
220
258

5
7
9
11
17
20
25
31
43
47
55
70
90
100
115
135
190
220
258
240












65
75
85
100
125
160
185
220
230

CL00
CL01
CL02
CL25
CL04
CL45
CL06
CL07
CL08
CL09
CL10
CK75C
CK08C
CK85B
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B

Motorstarters

230V 400V 415V 440V 500V 690V 1000V


220V 380V
kW kW kW kW kW kW kW

A
B
C
D
E
F

18
25
37
48
60
72
85
106
123
147
165
190
210
240
273
305
348
453
570
750

Electrical endurance 106 x 1.3 operations

G
H
I
X

D.60

(1) Power values shown are not standard as they refer to intermittent service.
(2) The current shown relates to the delta connection of the contactor poles.
If the poles are star-connected, divide the values given in the column by 1.5.

Rotor voltage Rotor voltage Contactor


without
with
counter-
countercurrent
current
690
690
690
690
690
750
750
750
750
750
750
1000
1000
1000
1000
1000
1000
1000
1000
1000

500
500
500
500
500
600
600
600
600
600
600
750
750
750
750
750
750
750
750
750

CL00
CL01
CL02
CL25
CL04
CL45
CL06
CL07
CL08
CL09
CL10
CK75C
CK08C
CK85B
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B

690
690
690
690
690
750
750
750
750
750
750
1000
1000
1000
1000
1000
1000
1000
1000
1000

500
500
500
500
500
600
600
600
600
600
600
750
750
750
750
750
750
750
750
750

CL00
CL01
CL02
CL25
CL04
CL45
CL06
CL07
CL08
CL09
CL10
CK75C
CK08C
CK85B
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B
continued on D.61

Series M, CL, CK

Motor power (1)


Rotor circuit (continued)


Contactor

230V 400V 415V 440V 500V 690V 1000V


220V 380V
kW kW kW kW kW kW kW

Jogging
35% AC-2

1.4
2.2
3
4.9
6.7
7
9
10.5
13.5
18.5
19.6
25
30
35
40
46
63
79
91
115

2.8
3.8
5.5
9
12.8
13
15
18.5
24
29
34
45
55
78
75
83
110
136
157
200

3.4
4.5
7.5
10
14.8
15
18
22
28
33
39
47
63
80
85
100
132
157
165
200

3.4
4.5
7.5
10
14.8
15
18
22
28
33
39
47
63
80
85
100
132
157
176
200

3.4
4.5
7.5
10
14.8
15
18
22
28
33
39
47
63
80
85
100
132
160
188
220

4

5.5

7.5

11

13
17

20

25

33

40

45

55
60
77
63
90
75
100 80
135 117
150 132
190 160
220 185
205 202

CL00
CL01
CL02
CL25
CL04
CL45
CL06
CL07
CL08
CL09
CL10
CK75C
CK08C
CK85B
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B


Rotor
current

(2)



14

20

26

42

50

57

70

85

100

120

138

155

172

200

225

250

285

385

495

637

Electrical endurance 106 x 1.3 operations


(1) Power values shown are not standard as they refer to intermittent service.
(2) The current shown relates to the delta connection of the contactor poles.
If the poles are star-connected, divide the values given in the column by 1.5.

Rotor voltage Rotor voltage Contactor


without
with
counter-
countercurrent
current
660
660
660
660
660
750
750
750
750
750
750
1000
1000
1000
1000
1000
1000
1000
1000
1000

500
500
500
500
500
600
600
600
600
600
600
750
750
750
750
750
750
750
750
750

CL00
CL01
CL02
CL25
CL04
CL45
CL06
CL07
CL08
CL09
CL10
CK75C
CK08C
CK85B
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B

Contactors for rotor speed drives

Stator circuit (continued)

A
B
C
D
E
F
G
H
I
X

D.61

Series M, CL, CK
Contactors for connection of power transformers
In this application it is essential to ascertain the no-load
inrush current of the transformer I, (magnetisation
current) which in the majority of cases determines the size
of the contactor.

Motorstarters

Two cases are illustrated in the table:


No-loap inrush current up to 20 times the rated
transformer current
No-loap inrush current up to 40 times the rated
transformer current.

A
B
C
D
E
F
G
H
I
X

D.62

Selection table
I
Ie























= 20

230V
240V
kVA

380V
400V
kVA

2
2.75
4
5.75
5.75
7.25
9
10
12
15
20
25
30
35
40
45
50
80
100
127
160

3.5
5
7
10
10
12.5
15.5
17
21
25
35
40
50
55
60
75
85
150
170
215
280

Ie


230V
240V
kVA
1
1.37
2
2.85
2.85
3.65
4.50
5
6
7.5
10
12.5
15
17
20
22
25
40
50
64
80

= 40
380V
400V
kVA
1.75
2.5
3.5
5
5
6.25
7.75
8.5
10.5
12.5
16
20
25
27
30
35
42.5
75
85
107
140

Contactor

CL00A
CL01A
CL02A
CL25A
CL03A
CL04A
CL45A
CL05A
CL06A
CL07A
CL08A
CL09A
CL10A
CK75C
CK08C
CK85B
CK09B
CK10C
CK11C
CK12B
CK13B

The contactor should not cut out the short-circuit current; if


the protective devices used are fuses, this condition will be
intrinsically complied with.
In the case however of devices with tripping contacts the
general line circuit breaker will be driven rather than the
contactor coil.

Series M, CL, CK
Contactors for capacitors (category AC6b)
GE Power Controls contactors are fitted with specially
treated hardened alloy contacts which are highly resistent
to welding and are therefore capable of withstanding high
current peaks on connection.
The operation conditions taken as a basis for usage are:
- Near presence of other previously connected capacitors
with a total power of up to eight times that of the
capacitor to be connected.
- Shock coils reactances with a minimum inductance of
4H. These can be obtained by making 4 or 6 turns of
15cm windings on the conductor of each phase.
- Fast discharge resistor for reconnection within
60 seconds.

Diagram

Line
transformer

Contactors for capacitors

The most usual application of capacitors is for centralised


automatic power factor (cos ) correction. A characteristic
of capacitors is the high overcurrent which appears as
they are connected.
Such overcurrents are due to:
- Harmonic currents produced by saturated transformers,
rectifiers, etc.
- Transient currents, the frequency and amplitude of
which depend on the network inductance and the
capacitor size.
- Additional transient currents arising where a capacitor is
connected when others have already been connected,
and caused by discharging of the latter.

Reactances

Shunt connected
capacitors

A
Fuses

Contactor

Fast discharge resistors

Capacitor
bank

Selection table
55C

Contactor
Type


CL00A
CL01A
CL02A
CL25A
CL03A
CL04A
CL45A
CL06A
CL07A
CL08A
CL09A
CL10A
CK75C
CK08C
CK85B
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B

Ith

220V

400V
415V
500V
230V
240V
A
kvar
kvar
kvar
kvar

3
5
5.5
6.5
25
4.5
9.5
10.5
12.5
25
6.5
11
12
14.5
32
7.5
12.5
14
16
45

9
15
16.5
20
45
12.5
21
23
27.5
60
16.5
25
27
32
60
22
40
43
52
90
45
48
58
110 25
50
54
65
110 30
65
70
85
140 40
70
80
90
140 45
110
118
145
250 60
125
135
162
250 70
150
160
195
315 80
165
177
215
315 95
190
205
250
450 105
260
280
340
600 135
325
350
425
700 190
400
430
520
1000 250
525
565
685
1250 315

70C
690V
660V
kvar
5.7
11
12.5
15
17.5
24
30
50
65
70
95
105
150
170
200
230
288
370
450
600
650

220V

400V
415V
500V
230V
240V
kvar
kvar
kvar
kvar
2.4
4
4.5
5.2
3.6
6
6.5
10
5.2
8.5
9
11.5
6.5
10
11
13
7.2
12
13
16
10
17
18
22
13
20
22
25
17
30
33
41
19
35
37
46
22
40
43
52
35
58
62
75
40
60
64
65
48
88
94
116
56
100
107
130
64
120
130
156
85
148
160
192
95
175
188
230
120
235
252
375
152
260
280
340
200
320
344
416
252
420
452
548

690V
660V

Fuse
gl - gG

I max.
(peak)

kvar
4.5
7
10
12
14
19.5
22
35
40
50
85
75
120
136
160
205
265
330
360
480
520

A

10
16
25
25
35
40
50
80
125
125
160
160
250
250
315
315
450
630
800
1000
1250

A
1000
1000
1000
1000
2500
2500
2500
3500
3500
3500
3500
3500
5000
5000
5000
5000
5500
10000
10000
12000
15000

E
F
G
H
I
X

Electrical endurance: 100.000 operations

D.63

Series M, CL, CK
Contactors for control lighting circuits
The characteristics of the most usual lighting systems are
as follows:

1.6 and 2 times the rated current and will hold for between
3 and 5 minutes.
The power factor is of the order of 0.6 and this can be
improved up to approximately unit value by means of
compensating capacitors. In such cases, the
connection power of the capacitor must be taken into
account, the effect of which is appreciably greater on the
smaller contactors.

Motorstarters

Incandescent lamps
The connection current in very high -of the order of 15
times- rated current. Although this is a very short
duration, it is only taken into account in order for the
contactor connection current not to be exceeded. The
power factor is always maintained at 1.

High pressure mercury vapour lamps


The connection current varies, depending on type, between

Selection table
Maximum number of lamps per phase at 230V

B
C
D
E
F
G
H
I
X

D.64

High pressure sodium vapour lamps


The connection current values varies, depending on type,
between 1.3 and 1.6 times the rated current and will hold
between 3 and 5 minutes.
The power factor is of the order of 0.45 and this can be
improved up to apporximately unit value by means of
compensating capacitors. In such cases, the
connection power of the capacitor must be taken into
account, the effect of which is appreciably greater on the
smaller contactors.

Fluorescent lamps
The connection current is slightly higher than rated
current. The power factor is about 0.5. To improve up to
0.9, compensating capacitors can be used. In such cases,
the connection power of the capacitor must be taken into
account, the effect of which is appreciably greater on the
smaller contactors.

Types

Incandescent






Fluorescent
Single arrangement
Without compensation


Fluorescent
Single arrangement
With compensation


High pressure mercury
vapour
Without compensation

High pressure mercury
vapour
With compensation

High pressure sodium
vapour
Without compensation
High pressure sodium
vapour
With compensation
Metal iodide
Without compensation



Metal iodide
With compensation


60
0.27
100 0.45
200 0.91
300 1.36
500 2.27
1000 4.5
2000 9.1
15
0.23
20
0.37
40
0.44
65
0.7
100
1.5
15
0.23
20
0.25
40
0.3
65
0.45
100
0.7
250 2.13
400 3.25
700
5.4
1000 7.5
250
1.3
400
2.1
700
3.6
1000 5.3
250
3
400
4.4
1000 10.3
250 1.45
400
2.5
1000 5.5
250 2,17
400 3,48
700 6,09
1000 8,7
2000 17,39
250
1,4
400
2,0
700
3,6
1000 5,3
2000 10,6

3.5
4.5
4.5
7
18

20
25
40
60

40
45
100
32
45
65
85
100

MCR

MC0

MC1

MC2

RL

CL00

CL01

27
16
8
5
3
1
0
51
32
28
18
8
26
20
20
13
5
5
3
2
1
9
7
5
3
3
2
1
5
4
2
3
2
1
1
0
0
0
0
0
0

37
22
11
7
4
2
1
61
38
33
21
10
32
25
25
14
6
5
3
2
1
9
7
5
3
3
2
1
5
4
2
3
2
1
1
0
6
4
2
2
0

59
35
17
11
7
3
1
79
49
41
26
12
49
38
38
25
9
5
4
2
2
9
7
5
3
4
3
1
5
4
2
4
2
1
1
0
6
5
3
2
0

59
35
17
11
7
3
1
79
49
41
26
12
49
38
38
25
9
6
4
2
2
9
7
5
3
4
3
1
5
4
2
4
3
1
1
1
7
5
3
2
0

59
35
17
11
7
3
1
79
49
41
26
12
49
38
38
25
9
6
4
2
2
11
7
4
3
4
3
1
10
6
3
4
3
1
1
1
7
5
3
2
0

62
40
20
13
8
4
1
88
57
48
30
14
61
48
48
31
11
6
4
2
2
11
7
4
3
4
3
1
10
6
3
4
3
1
1
1
7
5
3
2
1

62
40
20
13
8
4
1
98
61
51
32
16
77
61
61
39
14
8
5
3
2
14
9
5
3
5
4
2
12
7
3
5
3
2
1
1
9
6
3
2
1

CL02

CL25

70
50
25
17
10
5
2
126
78
66
41
19
94
74
74
47
17
10
6
4
3
18
11
6
4
7
5
2
16
9
4
7
4
2
2
1
11
8
4
3
2

77
60
30
20
12
6
3
155
110
93
58
27
111
87
87
56
21
12
8
5
3
22
14
8
5
9
6
2
20
11
5
9
6
3
2
1
16
11
6
4
2

Diagrams
Single-phase circuit
The total number of lamps will be as
shown in the table.

3-phase circuit,
lamps delta-connected
The total number of lamps will be as
shown in the table, multiplied by 1.73
and distributed in three equal
quantities.

3-phase circuit,
lamps star-connected
The total number of lamps will be as
shown in the table, multiplied by 3 and
distributed in three equal quantities.

Maximum number of lamps per phase at 230V


CL03

CL04

CL45

CL06

CL07

CL08

CL09

CL10

77
60
30
20
12
6
3
177
125
105
66
30
119
92
92
59
23
14
9
5
4
31
25
16
10
10
7
3
16
14
7
12
8
4
3
2
21
15
8
6
3

85
66
33
22
12
6
3
224
139
118
74
34
134
103
103
66
23
15
10
6
4
27
17
10
7
11
7
3
25
14
6
12
8
4
3
2
21
15
8
6
3

122
73
36
24
14
7
3
237
147
124
78
36
149
115
115
74
29
18
12
7
5
33
20
12
8
13
9
4
30
17
8
12
8
4
3
2
21
15
8
6
3

156
95
47
31
19
9
4
355
221
186
116
54
191
148
148
95
37
27
18
11
8
49
31
18
12
19
13
6
44
26
12
19
12
7
5
2
32
23
13
8
4

191
116
58
38
23
11
5
390
243
204
127
59
232
180
180
115
45
30
20
12
9
55
34
20
13
21
15
6
49
29
13
21
13
7
5
3
36
25
14
9
5

222
133
66
44
26
13
7
434
270
227
142
66
273
212
212
136
53
33
22
13
9
60
37
22
15
24
16
7
54
31
14
23
14
8
6
3
39
28
15
10
5

264
160
79
53
31
16
8
496
309
260
163
76
312
243
243
155
60
36
24
14
10
66
41
24
16
26
18
7
59
34
16
25
16
9
6
3
43
30
17
11
6

284
170
84
56
33
17
8
553
344
289
181
85
347
270
270
173
67
42
28
17
12
77
48
28
19
30
20
9
69
40
18
29
18
10
7
4
50
35
19
13
7

CK75C CK08C

CK09

CK95

CK10

CK11

CK12

CK13

555
333
165
110
66
33
16
1245
774
650
409
190
786
610
610
393
152
95
62
38
27
156
125
78
52
68
46
20
81
72
33
65
41
23
16
8
97
69
48
37
31

820
490
240
165
95
50
25
1770
1090
920
570
270
900
700
700
440
170
136
89
54
39
171
137
86
57
96
66
28
90
80
36
93
58
33
23
12
107
76
53
40
34

1320
790
390
260
155
80
40
2340
1460
1220
770
360
1240
960
960
610
240
181
119
71
51
311
249
156
104
129
88
37
163
145
65
124
78
44
31
16
195
138
96
73
62

1550
930
460
300
185
90
45
2740
1700
1430
900
420
1450
1120
1120
720
280
211
138
83
60
311
249
156
104
150
102
44
163
145
65
145
91
52
36
18
195
138
96
73
62

1860
1120
550
370
220
110
55
3910
2430
2045
1280
600
1740
1350
1350
860
330
302
198
119
86
374
299
187
125
214
146
62
195
174
78
207
129
74
52
26
234
166
115
88
75

1860
1120
550
370
220
110
55
4890
3040
2550
1600
750
1740
1350
1350
860
330
377
247
149
107
467
374
234
156
268
183
78
244
217
98
259
162
92
65
32
292
208
144
110
93

333
200
99
66
39
20
10
790
490
413
259
121
496
385
385
248
96
60
40
24
17
109
87
54
36
43
29
12
57
51
23
41
26
15
10
5
68
48
34
26
22

410
246
122
81
48
24
12
988
614
516
324
151
621
482
482
310
120
75
49
30
21
156
125
78
52
54
37
16
81
72
33
52
32
18
13
6
97
69
48
37
31

Contactors for lighting circuits

Series M, CL, CK

B
C
D
E
F
G
H
I
X

D.65

ASTAT S
Small soft starter with integral by-pass
ASTAT S is compact, easy to operate soft starter, designed for use with
standard 3-phase squirrel cage motors. It provides an advanced method of
reducing current during motor starting and stopping.
ASTAT S will start supplying a reduced voltage to the motor, increasing up to
the rated voltage, so avoiding, high currents and generating soft
starting and stopping.
The motor has to be able to start in a reduced voltage.

Motorstarters

Solid soft starter for standard 3ph AC motors up to 30kW


at 400V AC
Voltage ratings up to 600V
Two phase control with integral by-pass
Compact, small case
DIN rail mounting. Optional from 31A
Start and soft stop features

A
B
C

Marking

Technical data
Ratings

cULus
The cUL, is achieved for all range of ASTAT S,
except for 58A models, items QA02P058S,
QA12P058S, QA22P058S, QA32P058S.

Voltage ratings




Frequency range
Load

3ph AC systems
220/230V (+10%, -15%) for units QA02P_ _ _ S
380/415V (+10%, -15%) for units QA12P _ _ _ S
480/500V (+10%, -15%) for units QA22P _ _ _ S
575/600V (+10%, -15%) for units QA32P _ _ _ S
50/60Hz (5%)
3ph, AC standard motors

Control specifications

Ramp up
Ramp down
Initial voltage
Starting torque

0,5 - 10 s
0,5 - 10 s
0 - 80% Un
0 - 64% Tn

I/O control
Inputs
Outputs

F
G

Ambient conditions
Operating temperature
Storage temperature
Relative humidity
Max. altitude

Protection degree

H
I
X
Order codes !
Diagrams !
Performances !
Dimensions !

D.66

one input for Start/Stop


one output for End of Ramp signal
for ratings 31, 44, 58A

page D.67
page D.68
page D.69
page D.70

0 to 40C. Up to 60C derating by 1,2% per C


-20 to 70C
up to 80%, without condensation
up to 1000m.
Above this derate by 5% each 100m
IP20

ASTAT S
Small soft starter with integral by-pass
Input Current
voltage rating (2)
V CA
A
220
8


17


22


31


44


58

Maximum motor power (1)


Maximum
Cat. No.
Ref. no. Pack
current 220/230V 380/415V 480/500V 575/600V
A
kW / Hp kW / Hp kW / Hp kW / Hp

28
1.5 / 2
-
-
-
QA02P008S 120881 1
60
4 / 5.5
-
-
-
QA02P017S 120882 1
77
5.5 / 7.5
-
-
-
QA02P022S 120883 1
110
7.5 / 10
-
-
-
QA02P031S 120884 1
150
11 / 15
-
-
-
QA02P044S 120885 1
200
15 / 20
-
-
-
QA02P058S 120886 1

8
17
22
31
44
58

28
60
77
110
150
200

-
-
-
-
-
-

4 / 5.5
7.5 / 10
11 / 15
15 / 20
22 / 30
30 / 40

-
-
-
-
-
-

-
-
-
-
-
-

QA12P008S
QA12P017S
QA12P022S
QA12P031S
QA12P044S
QA12P058S

120892
120893
120894
120895
120896
120897

1
1
1
1
1
1

500









8
17
22
31
44
58

28
60
77
110
150
200

-
-
-
-
-
-

-
-
-
-
-
-

5.5 / 7.5
11 / 15
15 / 20
22 / 30
30 / 40
45 / 60

-
-
-
-
-
-

QA22P008S
QA22P017S
QA22P022S
QA22P031S
QA22P044S
QA22P058S

120898
120899
120900
120901
120902
120903

1
1
1
1
1
1

600










8
17
22
31
44
58

28
60
77
110
150
200

-
-
-
-
-
-

-
-
-
-
-
-

-
-
-
-
-
-

7.5 / 10
15 / 20
22 / 30
30 / 40
37 / 50
55 / 75

QA32P008S
QA32P017S
QA32P022S
QA32P031S
QA32P044S
QA32P058S

120904
120905
120906
120907
120908
120909

1
1
1
1
1
1

QAOPTDIN 120910

Accessory

DIN rail mounting kit for types 31A, 44A and 58A

(1) Ratings for standard 4-poles AC motors


(2) See Operations/hour in table below
Cycles/hour includes both soft start and soft stop

A
B
C

Times between rampings Start/Stop



Starting
Ramp 1 sec.

current
QA_2P008S
8
7

16
16

24
26

28 (*)
32
QA_2P017S 17
7

34
16

51
26

60 (*)
32
QA_2P022S 22
7

44
16

66
26

77 (*)
32
QA_2P031S 31
4

62
8

93
12

110 (*)
15
QA_2P044S 44
4

88
8

132
12

155(*)
15
QA_2P058S 58
4

116
8

174
12

200 (*)
15
(*) Maximum starting current at all

Small soft starters

400









Ramp 2 sec.

Ramp 5 sec.

Ramp 10 sec.

15
33
51
62
15
33
51
62
15
33
51
62
8
15
24
31
8
15
24
31
8
15
24
31

35
77
125
155
35
77
125
155
35
77
125
155
20
38
62
80
20
38
62
80
20
38
62
80

70
155
250
-
70
155
250
-
70
155
250
-
40
76
124
-
40
76
124
-
40
76
124
-

D
E
F
G
H
I
X

D.67

ASTAT S
Diagrams
Control by push-buttons,
line contactor and thermal overload
relay (soft start)

Motorstarters

Control by permanent command


(soft start and stop)

start/stop

A
B

Control by push-buttons and line


contactor (soft start)

Forward/reverse control by
push-buttons (3)

C
D
E
F
G
H
I
X


Motor power
ASTAT S
Q1
Q2
KM1
Q3
380/415V
Thermal
Hp
Am fuses
Contactor overload relay
kW
4
7.5
11
15
22
30

QA12P008
QA12P017
QA12P022
QA12P031
QA12P044
QA12P058

GPS1B*AK
GPS1B*AN
GPS1B*AP
GPS1B*AR
GPS2B*AT
GPS2B*AU

10
25
32
40
63
80

CL25A
CL25A
CL25A
CL04A
CL06A
CL07A

Coordination type 1
(1)
(2)
(3)
(4)

D.68

5.5
10
15
20
30
40

Use dry contact only.


End of Ramp output relay (only types 31A, 44A and 58A.
Forward/Reverse operation must be done when motor is not rotating.
Ground terminal only for types 31A, 44A and 58A.

RT A 1N
RT A 1S
RT A 1T
RT A 1V
RT A 2F
RT A 2H

F1-F2

S1-S2-S3

-
-
-
-
-
-

P9-P3
P9-P3
P9-P3
P9-P3
P9-P3
P9-P3

ASTAT S
Performances
Direct-on-line start

ASTAT S soft start

DOL

Speed

Current
Speed

Time

Direct-on-line stop

Time

RAMP DOWN 0.5s

B
C
D

Current

Current

Voltage

Voltage

ASTAT S soft stop

DOL

Small soft starters

Current

Voltage

Voltage

Uo=0.5Un, To=25Tn, RAMP UP 0.9s

Speed

Speed

E
Time

Time

F
G
H
I
X

D.69

ASTAT S
Dimensional drawings
Small soft starter with integral by-pass
TYPE
Weight (kg)
QA_2P017S
0.610
QA_2P022S
0.650
QA32P008S
0.650

Motorstarters

TYPE
Weight (kg)
QA12P008S
0.470
QA22P008S
0.470

Dimensions in mm

Dimensions in mm

TYPE
QA_2P031S
QA_2P044S
QA_2P058S

Weight (kg)
1.370
1.400
1.400

B
2

D
E
F
G
H
I
X
Dimensions in mm

D.70

ASTAT XT
ASTAT XT

Digital soft starters for 3ph standard


induction motors

ASTAT XT Soft Starter offers reliable performance and smooth acceleration


for a variety of standard AC motors up to 1400A and up to 690V, reducing
mechanical shock to the driving system, resulting in extended component
and motor life.

Approvals / Marking

ASTAT XT offers many traditional features such a motor overload function,


adjustable ramps, current limit, kick start, but also other high end features
like Inside-Delta operation, Torque Control, Pump control and a reliable motor
and unit set of protections.

Key Features
For units up to 820A. U type

Control panel

Ratings up to 1400Amps and up to 690VAC


Friendly multilanguage interface with two rows, sixteen characters each
Built-in with three extra power terminals for external bypass
In-Line or Inside-Delta operation modes
Torque control and pump control advanced features
Motor protection according IEC 10, 20 and NEMA 10, 20, 30, even if
ASTAT XT is in By-pass
Built in communications RS485 port, and ModBus protocol as standard
Profi busDP and DeviceNet optional interfaces for communications

Digital Soft Starters

GEs new ASTAT XT solid state soft starter features microprocessor control
digital technology. Setup and adjustment is performed through a six-buttom
keypad and parameters or messages are displayed out trough a friendly
LCD multilanguage interface with two rows, sixteen alphanumeric characters
each. The design includes isolated I/O and high level of protection in their
circuits to minimize the disturbance effects while working in the hardest
industrial environment.

A
B
C
D
E
F
G
H
I
X

D.71

ASTAT XT
IEC ratings. Recommended motor and type unit ratings
Light
Duty

NORMAL DUTY
(IEC Class 10)

HEAVY DUTY
(IEC Class 20)

Max
Current Rated
400V- 480VRated
400V- 480VRating Current 230V 415V 500V 690V Current 230V 415V 500V 690V

Digital Soft Starters

Mains voltage
230-500VAC

Mains voltage
690VAC

A
B
C
D

Cat. No.

Ref. No.

A
8
17
34
54
65
72
104
130
156
170
248
361
390
480
480
610
610
820
820
1180
1375
1750

A
8
17
31
44
58
72
85
105
145
170
210
310
390
460
460
580
580
650
820
950
1100
1400

kW
1.5
4
7.5
11
15
22
22
30
45
55
55
90
110
132
132
160
160
200
250
315
355
400

kW
3
7.5
15
22
30
37
45
55
75
90
110
160
200
250
250
315
315
355
400
560
630
800

kW
4
7.5
18.5
30
37
45
55
55
90
110
132
200
250
315
315
400
400
400
560
630
800
1000

kW
-

A
8
12
31
44
55
66
80
99
130
134
203
310
344
432
432
488
552
552
690
950
1076
1400

kW
1.5
3
7.5
11
15
18.5
22
30
37
37
55
75
110
132
132
160
160
160
200
315
355
400

kW
3
5.5
15
22
30
37
45
55
55
75
110
160
160
250
250
250
315
315
400
560
630
800

kW
4
5.5
18.5
30
37
45
55
55
90
90
132
200
250
315
315
355
400
400
500
630
800
1000

kW
-

QT10008U21MS
QT10017U21MS
QT10031U21MS
QT10044U21MS
QT10058U21MS
QT10072U21MS
QT10085U21MS
QT10105U21MS
QT10145U21MS
QT10170U21MS
QT10210N21MS
QT10310N21MS
QT10390N21MS
QT10460N21MS
QT10460U21MS
QT10580N21MS
QT10580U21MS
QT10650N21MS
QT10820U21MS
QT10950N21MS
QT11100N21MS
QT11400N21MS

169075
169076
169077
169078
169079
169080
169081
169082
169083
169084
169091
169092
169093
169094
169088
169095
169089
169096
169090
169097
169098
169099

8
17
34
54
65
72
104
130
156
170
248
361
390
480
610
820
1180
1375
1750

8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
650
950
1100
1400

5.5
15
22
37
55
55
75
90
132
160
200
250
355
400
560
630
900
1000
-

8
12
31
44
55
66
80
99
130
134
203
310
344
432
488
552
950
1076
1400

5.5
7.5
22
37
45
55
75
90
90
132
200
250
315
400
400
560
900
1000
-

QT30008N21MS
QT30017N21MS
QT30031N21MS
QT30044N21MS
QT30058N21MS
QT30072N21MS
QT30085N21MS
QT30105N21MS
QT30145N21MS
QT30170N21MS
QT30210N21MS
QT30310N21MS
QT30390N21MS
QT30460N21MS
QT30580N21MS
QT30650N21MS
QT30950N21MS
QT31100N21MS
QT31400N21MS

169119
169120
169121
169122
169123
169124
169125
169126
169127
169128
169129
169130
169131
169132
169133
169134
169135
169136
169137

Remark
Motor kW ratings given in above table are for IEC, standard AC four poles motors.
Always check that motor rated current is less than the specifi ed rated current of the starter, for the specifi c
application (Normal Duty or Heavy Duty)

E
F
G
H
I
X

QT10008U21MS
ASTAT XT 8A-72A

D.72

QT10105U21MS
ASTAT XT 105A-170A

QT10210N21MS
ASTAT XT 210A-390A

QT10460N21MS
ASTAT XT 460A-650A

ASTAT XT
NEMA ratings. Recommended unit type and motor ratings
LIGHT DUTY
Nema 10
Current
Rating 230V
Mains voltage
230-500VAC

Current
575V Rating 230V

460V

HEAVY DUTY
Nema 30
Current
575V Rating 230V

460V

575V

Cat. No.

Ref. No.

A
8
17
34
54
65
72
104
130
156
170
262
387
414
480
610
820

HP
2
5
10
20
20
25
40
50
60
60
100
150
150
200
250
-

HP
5
10
25
40
50
50
75
100
125
125
200
300
350
400
500
-

HP
-

A
8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
820

HP
2
5
10
15
20
25
30
40
50
60
75
100
150
150
200
250

HP
5
10
20
30
40
50
60
75
100
125
150
250
300
350
400
500

HP
-

A
8
12
31
44
55
66
80
99
130
134
203
310
361
432
552
690

HP
2
3
10
15
20
20
30
40
50
50
75
100
150
150
200
250

HP
5
7.5
20
30
40
50
60
75
100
100
150
250
300
350
400
500

HP
-

QT10008U21MS
QT10017U21MS
QT10031U21MS
QT10044U21MS
QT10058U21MS
QT10072U21MS
QT10085U21MS
QT10105U21MS
QT10145U21MS
QT10170U21MS
QT10210U21MS
QT10310U21MS
QT10390U21MS
QT10460U21MS
QT10580U21MS
QT10820U21MS

169075
169076
169077
169078
169079
169080
169081
169082
169083
169084
169085
169086
169087
169088
169089
169090

8
17
34
54
65
72
104
130
156
170
262
387
414
480
610
820

5
10
25
40
50
50
75
100
125
125
200
300
350
400
500
-

5
15
30
50
60
60
100
125
150
150
250
400
400
500
-

8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
820

5
10
20
30
40
50
60
75
100
125
150
250
300
350
400
500

5
15
25
40
50
60
75
100
150
150
200
300
400
400
400
500

8
12
31
44
55
66
80
99
130
134
203
310
361
432
552
690

5
7.5
20
30
40
50
60
75
100
100
150
250
300
350
400
500

5
10
25
40
50
60
75
100
125
125
200
300
300
400
500
-

QT20008U21MS
QT20017U21MS
QT20031U21MS
QT20044U21MS
QT20058U21MS
QT20072U21MS
QT20085U21MS
QT20105U21MS
QT20145U21MS
QT20170U21MS
QT20210U21MS
QT20310U21MS
QT20390U21MS
QT20460U21MS
QT20580U21MS
QT20820U21MS

169100
169101
169102
169103
169104
169105
169106
169107
169108
169109
169110
169111
169112
169113
169114
169115

Remark
Motor HP ratings given in above table are for NEMA, standard AC four poles motors.
Always check that motor rated current is less than the specified rated current of the starter, for the specific
application (Light duty, Normal duty or Heavy duty)

Order codes

Mains voltage
460-600VAC

460V

NORMAL DUTY
Nema 20

A
B
C
D
E
F
G
H
I
X

D.73

ASTAT XT
Unit configuration

QT

0008

Astat XT range

Digital Soft Starters

Main voltage

A
B
C
D
E
F
G
H
I
X

D.74

230-500V
460-600V
690V

1
2
3

UL Certification(1)

UL
non-UL

U
N

Control voltage(2)

110VAC
230VAC

1
2

Digital inputs, voltage(3)

90-230VAC 1
24VDC
2

Communications

Standard
Profibus
DeviceNet

Current ratings

Future
options

M
P
D

(1) - ASTAT XT up to 600V, and up to 170A (Cat Numbers up to QT10170_ or up to QT20170) are always cUL certified. Option N not available
- Units QT2, from QT20008_, up to QT20820_ are always cUL certified. Option N not available.
- Units QT1, or QT2 from QTx0950_ up to QTx1400 are not UL certified. Option U not available.
- Units QT3__, rated to 690V, are not UL certified. Option U not available
(2) ASTAT XT standard Control Voltage configuration is option 2, Voltage 230VAC, +10%, -15%
(3) ASTAT XT standard configuration for Inputs is option 1, Voltage 90-230VAC, +10%, -15%

ASTAT XT
Technical Data
Ratings
3Ph AC supply

Main voltage
Starter current rating
Motor current rating
Control voltage

for 3Ph AC motors


3 phases Induction motors
1ph AC supply

Frequency range

50/60Hz systems

230 to 500VAC +10%, -15% for QT1xxx units


460 to 600VAC +10%, -15% for QT2xxx units
690VAC +10%, -15% for QT3xxx units
From 8A up to 1400A.
Motor rated current from 50% to 100% of starter current
230VAC, +10, -15%, 50/60Hz, or
110VAC, +10, -15%, 50/60Hz (optional)
Wide from 45Hz to 65Hz. Auto-tracking frequency range

Control specifications
Control system

Initial voltage
Starting current
Acceleration ramp time
Deceleration ramp time
Current limitation
Bypass
Monitoring

Environmental conditions
Operating temperature
Storage temperature
Maximum altitude
Humidity
Protection degree
Pollution degree

-10 up to 50C, with current derating by 2.5% per C, from 40C


-20C up to 70C
Up to 1000 mts. Ask your dealed for installation at higher altitude
95% at 50C or 98% at 45C
IP20 for units up to 72A, IP00 for units from 85A up to 1400A
Class 3

Safety

B
C

Standards
Global standards
EMC emissions
Immunity

Technical Data

Operation mode
Run operation
Operator interface

Digital control with microcontroller.


Starting ramp, with progressive increase in voltage and current limitation
In-Line (three wires) or Inside-Delta (six wires) of the motor
Soft Start and Soft stop by multiple choices, including torque control both at start or Stop phases
By LCD display, keypad and Indication LEDs
Display: LCD with two rows, 16 characters each
Type: Multilanguage, dip-switch selectable for English, Italian, Spanish and German
Keys: Six keys, Mode, reset, Set, Select and Up / Down
LEDs: ON, Start, Run, Soft Stop, Stop, Save / Slow Speed, Dual Set / Reverse and Fault
10-50% Un. Up to 80% with expanded settings function
100-400% In. Can be extended up to 500%, by using extended settings
1-30 sec. Can be extended up to 90sec, by using extended settings
1-30 sec. Can be extended up to 90sec, by using extended settings
100-400% of motor rated current. Can be extended up to 500% by using extended settings
By external contactor while motor is full protected by ASTAT XT.
Motor Current, Line Voltage, motor thermistor resistance, Test & Maintenance and Statistics

CE for the full trange. UL, cUL for specifi ed units up to 820A
EN 61000-6-4
CISPR 11 Class A
EN 61000-6-2
ESD 8KV air, IEC 801-2;
Electric RF fi eld 10 V/m, 20-1000Mhz, IEC 801-3
Fast transients 2KV, IEC 801-4
EN 600947-1
Related to safety requirements. UL508C

D
E
F
G
H
I
X

D.75

ASTAT XT
Functions
Available standard functions
Soft start and soft stop

Pump control
Torque control

Digital Soft Starters

In line / Inside delta

Bypass

Kick start

End of ramp
Lock-Out
Dual settings

Energy saving

Slow speed
Auto reset

B
C

Cooling fan control

Generator supply

Keypad lock

Built-in communications
Statistic data

ASTAT XT is provided with a soft start and soft stop features, including five independent acceleration and
decelertaion curve models.
The factory default curve is used for general purpose, other three are used for pump control and the last one for
torque control.
Specific function for pump control, that avoids overpressure in the system at the end of acceleration phase and
suppresses the hammering at stopping phase.
Provides a smoth time controlled torque ramp acelleration and deceleration, with linear deceleration of the torque
resulting in a close to linear speed deceleration, thus eliminating stall conditions
ASTAT XT allows either traditional Line operation or Inside Delta operation.
When the ASTAT XT is installed to operate Inside Delta, the individual phases of the starter are connected in series
with the individual motor windings (six wiring connections like the Start-Delta starters), thus reducing the current
x1.73, and allowing the use of a much smaller starter (x1.5 less than motor rated current).
ASTAT XT allows bypass operation using an external contactor, controlled ON/OFF by starter function EOR
(End Of Ramp).
The starter is provided with three dedicated power terminals to facilitate wirings to the bypass contactor.
ASTAT XT protections to motor are enabled, even in bypass.
This function allows to start high friction loadsthat require high starting torque for a short period of time. When
this function is enabled, a pulse of 80% Un during an adjustable time from 0 to 1sec is given to the motor. After
this pulse the output voltage is ramping down to Starting Voltage setting, before ramping up again to full voltage.
Detects end of acceleration and outputs a signal by an dry relay contact. This signal can be delayed by an
adjustable timer from 0-120 sec.
Allows to control the number of startings into a period of time, then protecting both motor and ASTAT.
By this function, ASTAT XT is able to control a secondary motor Dual setting of Starting Voltage, Starting Current,
Current Limit, Ramp Up, Ramp Down and Motor current parameters can be selected by using one of the programmable ASTAT XTs inputs
Activated when the motor has a light load for extended periods of time, then reducing the output voltage level
and decreasing the reactive current and motor copper/Iron losses.
This function can be enabled or disabled by dedicated parameters in ASTAT XT.
Function that allows the motor to run at 1/6 constant rated speed, for a short period of time of maximum 30sec.
This function supports forward and reverse operation.
This function allows the ASTAT XT automatic recover after a fault caused by Undervoltage, Undercurrent or
Phase lost. Auto-Reset can be programed up to maximum 10 attempts.
Allows thre method of control for the ASTATs built-in cooling fans.
- Continuous Operation
- Controlled by an external Input
- Automatically OFF controlled, after five minutes ASTAT XT is stopped
This is a specific function useful when the Starter is powered from a diesel generator rather than from
commercial power supply. The function is enabled by an internal Dip Switch, and helps to minimize the negative
effects caused by the generators voltage fluctuations during starting.
This function is enabled by means of starters internal dipswitch, then locking the keypad.
This is usefull to prevent undesired parameter modifications.
ASTAT XT includes a ModBus RTU communications protocol. Communications are carried out through a half duplex
RS485 port, with maximum baudrate of 9600, supporting up to 247 stations.
ASTAT XT records useful data for maintenance and start up
- Last 10 trip events
- Statistical data like number of starts, number of trip events and elapsed RUN time.
- Last trip data information of Motor current, Starting current and acceleration time.

Motor and starter protection

F
G
H
I
X

D.76

Overload
Motor thermistor
Too many starts
Long start time
O/C JAM fault

Undercurrent
Undervoltage
Overvoltage
Phase loss
Frequency loss
Phase sequence
Slow speed time
Wrong connection
Shorted SCR
Over temperature
External fault
Wrong parameters
OC or wrong CON

Trips the ASTAT-XT when current exceeds the Overload Trip level according IEC Class 10, 20 or NEMA 10, 20, 30
Trips when motor thermistor resinstance decreases below trip level set ASTAT XT allows both PTC or NTC sensors,
with adjustable trip level
Trips if the number of starts, during Duty Cycle Time exceeds the preset number
Trips if output voltage does not reach rated voltage at the preset Max. Start time
Trips under the following conditions:
- Instantaneously when current exceeds 8.5 x ASTAT-XT Current
- During starting when current exceeds 8.5 x Motor Current
- During running when current exceeds 200-850% of Motor Current
O/C JAM has a programmable triping delay of 0-5 seconds
Trips when line current drops below the preset level for the preset time.
Trips when line voltage drops below the preset level for the preset time.
Trips when line voltage increases above a preset level for a preset time
Trips if 1 or 2 phases are lost
Trips if frequency is not in the range of 40-66.6Hz
Trips if line phase sequence is wrong
Trips when operating at slow speed for extended periods
Trips the ASTAT-XT when one or more motor phases is not properly connected to ASTAT-XTs load terminals
or if there is an internal disconnection in the motor winding
Trips and prevents starting if any SCR is short-circuited or when motor windings are shorted
Heat-sink over-temperature. Trips the ASTAT-XT when the heat-sink temperature rises above 85C
Trips the ASTAT-XT when a N.O. contact between terminals 19-21 closes for over two seconds
Parameters not transferred from RAM to EEPROM or vice versa
Trips when the ASTAT-XT is connected Inside Delta and Wrong connection or overcurrent is detected

ASTAT XT
Overload protections - Thermal characteristics
The ASTAT XT allows motor protection according IEC Class 10 or Class 20 and NEMA 10, 20 or 30, user free selectable by ASTAT
internal dedicated parameter.

IEC Class 10

IEC Class 20
Sec.
10000

1000

1000

100

100

Overload protections

Sec.
10000

COLD
COLD
10

10
HOT

HOT
1
1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0
Multiples of motor FLA Rating In

NEMA 10 Light duty

1
1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0
Multiples of motor FLA Rating In

NEMA 20

Sec.
10000

Sec.
10000

1000

1000

100

100

B
C
COLD

COLD
10

10

HOT
1
1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0
Multiples of motor FLA Rating In

HOT
1
1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0
Multiples of motor FLA Rating In

E
F

Maximum number starting /hour

NEMA 30

Ramp time
Sec.
10000
Starting
current
I/In (1)

1000

100

COLD

10s

20s

30s

24

12

16

12

G
H

(1) In= rated current of ASTAT XT in the specified class IEC/Nema

10
HOT
1
1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0
Multiples of motor FLA Rating In

D.77

ASTAT XT

A
3L2

2T1

CT2

5L3

6T3

10

11

12

Stop 4

13

Soft Stop 5

14

Start 6

15

E.Save/Slow Speed/Reset 7

16

D.Adj./Reversing/Reset 8

17

Common 9

18

External Fault Input 19

SG

Control Supply

Neutral 21
Ground

T1 28
Thermistor Input

T2 29

D.78

Fault Relay

EOR (End Of Ramp)


Relay

RS485 Port

D+
Grd
31 (-)
32 (+)

Analog output

Ground 30

H
I

Inmediate
RUN

D-

M
3ph

4T2

B
C

CT1

Profibus Comm
(Option)

V-

Power Supply

CL

Signal CAN-H

Dr

Drain

CH

Signal CAN-L

V+

Power Supply

DeviceNet (Option)

1L1
Main Supply

Digital Soft Starters

I/O Wiring, Basic scheme

ASTAT XT
I/O terminal board specifications

Terminals

Function

1L1, 3L2, 5L3

Mains Input

2T1, 4T2, 6T3


A, B, C
G

Output to motor
By-pass
Ground

Description
3ph Input voltage according Astat XT Main Voltage Option rating
(Option 1, QT1_) 230-500VAC, +10%/-15% 50/60Hz
(Option 2, QT2_) 460-600VAC, +10%/-15% 50/60Hz
(Option 3, QT3_) 690VAC, +10%/-15% 50/60Hz
Power Output terminals to 3ph AC motor
Bypass terminals for external by-pass contactor
ASTAT XT, ground connection

Control power supply


L, N
F

Control. Supply
Fan control

a110VAC or 220VAC, according ASTAT XT Control Voltage rating


Cooling fan external control, together with jumper J1
Control Voltage & Fan consumption VA:
QTx0008 to QTx0031: No fan. Total consumption: 150VA
QTx0044 to QTx0072: Fan 35 VA. Total consumption 185VA
QTx0085 to QTx0170: Fan 60 VA. Total consumption 210VA
QTx0210 to QTx0390: Fans 105VA. Total consumption 255VA
QTx0390 to QTx 1400A : Fans 150VA.Total consumption 300VA

Digital inputs
4
5
6
7
8
9

Stop
Soft Stop
Start
Progammable Inputs
Progammable Inputs
Common

Dedicated input to Stop


Dedicated input to Soft Stop
Dedicated input to Start
Programmable to functions Energy Saving, Slow Speed and Reset
Programmable to functions Dual Set, Reverse and Reset
Common terminal for digital inputs from 4, 5, 6, 7 and 8
Operating Voltage of digital inputs from 4 to 9
Digital Input hardware is operated according either of below ordered voltage ratings
(Option 1, standard) From 90 to 230VAC +10%, 50/60Hz
(Option 2, Optional) 24VDC +10%/ -15%

I/O terminal board specifications

Power I/O terminals

A
B

Other inputs
19, 21
21
28, 29

External fault
Neutral
Motor thermistor

Requires a free voltage relay contact, to detect external fault


This terminal may be connected to Mains Neutral when available
PTC or NTC programable input for motor thermistor protection
The input can be enabled or disabled, and programmed at desired trip level resistance

Digital outputs
10, 11, 12
13, 14, 15
16, 17, 18

RUN
FAULT
EOR

Run Relay with NO & NC dry contact. Programmable ON delay


Fault to ON or Fault to OFF programmable function
End Of Ramp relay. Programmable ON delay

Relay Outputs Ratings


Max rating: 8A, 250VAC, 2000VA max

Analogue output
31, 32
30

Current output
Ground

Range 0 to 2xIn. Programmable 0-10VDC, 0-20mA or 4-20mA.


Ground terminal for Analog Output

Communications
D+, D-, SG

RS485 terminals

D-9 connector
V+, CL, Dr, CH, V-

Profibus port
DeviceNet terminals

RS485 Communication port, half duplex for ModBus protocol


Baudrate 1200, 2400, 4800, 9600 BPS
Optional Profibus Communications port
Optional Devicenet Communications port

G
H
I
X

D.79

ASTAT XT
Application wiring diagrams
Basic diagram without line contactor(1)
With Soft Start and coast to Stop
by Permanent Command Control

L1 L2 L3
Q1

Q3

Q2
0 STOP
I START

GND

START 6

SOFT STOP 5

STOP 4

5L3
6T3

COMMON 9

1L1

3L2

A1

4T2

F1

2T1

Digital Soft Starters

T1

EOR
R

18 17 16

FAULT
R

15 14 13

RUN
R

12 11 10

U1 V1 W1
M
3 ~

B
Basic diagram without line contactor(1)

With Soft Start and Soft Stop


by Permanent Command Control

L1 L2 L3
Q1

T1

Q3

Q2

0 STOP
I START

F1

START 6

STOP 4

SOFT STOP 5

5L3
6T3

GND

COMMON 9

1L1

3L2

4T2

A1

2T1

G
EOR
R

18 17 16

FAULT
R

15 14 13

RUN
R

12 11 10

U1 V1 W1
M
3~

D.80

(1) Schemes are given for information purposes. Add additional emergency safety stop, if it is required for your application.
Remarks
1. Check coordination tables for proper selection of Breaker and Line contactor.
2. Control Voltage and Control Input voltage are from same source in above example. Please check manuals if you have different sources for
Control Voltage and Control input Voltage.
3. Semiconductor Fuses F are only required for Type 2 coordination. Please check coordination tables
4. In spite of ASTAT XT can operate without line contactor, the use of a line contactor will increase the operation safety. Anyway provide a way to
switch off the Breaker in case of an emergency.

ASTAT XT
Application wiring diagrams
Basic diagram without line contactor(1)
With Soft Start and Soft Stop
by push-buttons control

L1 L2 L3
Q1

T1

Q3

Q2

EOR
R

START 6

SOFT STOP 5

STOP 4

5L3
6T3

COMMON 9

1L1

3L2

2T1

A1

4T2

START

GND

FAULT
R

18 17 16

15 14 13

RUN
R

Wiring diagrams

STOP
F1

12 11 10

U1 V1 W1
M
3~

B
Basic diagram with line contactor(1)
With Soft Start and coast to Stop
by push-buttons control

L1 L2 L3
Q1

3
1
KM1
.8 2

T1

2
13
Q1
.2 14

Q3

STOP

Q2
K1

21

KM1

START

24

K1

A1

13
FAULT
RELAY 15

F1

K1

A1
A2

13
14

K1

31
34

11

14
A1

10
RUN
RELAY 12

KM1

A1
A2

START 6

SOFT STOP 5

STOP 4

6T3

5L3

4T2

GND

COMMON 9

1L1

3L2

2T1

G
A1

EOR
R

FAULT
R

RUN
R

18 17 16

15 14 13

12 11 10

U1 V1 W1

H
I

M
3 ~

(1) Schemes are given for information purposes. Add additional emergency safety stop, if it is required for your application.
Remarks
1. C
 heck coordination tables for proper selection of Breaker and Line contactor.
2. C
 ontrol Voltage and Control Input voltage are from same source in above example. Please check manuals if you have different sources for
Control Voltage and Control input Voltage.
3. S
 emiconductor Fuses F are only required for Type 2 coordination. Please check coordination tables
4. In spite of ASTAT XT can operate without line contactor, the use of a line contactor will increase the operation safety. Anyway provide a way to
switch off the Breaker in case of an emergency.

D.81

ASTAT XT
Application wiring diagrams
Basic diagram with line contactor(1)
L1 L2 L3
Q1

With Soft Start and Soft Stop


by push-buttons control
1

Digital Soft Starters

KM1

.8 2

T1

2
13
Q1
.2 14

Q3

STOP

Q2

K1

21

START

24

FAULT
RELAY

13

GND

K1

31
34

14
A1

10

RUN
RELAY

15
A1

12
A1

KM1

A2

A2

FAULT
R

EOR
R

START 6

STOP 4

SOFT STOP 5

3L2

5L3
6T3

COMMON 9

1L1

4T2

A1

2T1

K1

14

11

K1

A1

F1

13

KM1

18 17 16

RUN
R

15 14 13

12 11 10

U1 V1 W1
M
3 ~

B
Basic diagram with line and bypass contactors(1)

L1 L2 L3
Q1

D
E

KM1
=8/1.8

With Soft Start and Soft Stop


by push-buttons control
1

T1

2
Q1

Q3

K1

21
24

KM1

K1

START
A1
FAULT
RELAY

I
X

BPC

GND

START 6

STOP 4

SOFT STOP 5

=8/1.9

COMMON 9

5L3

A1

3L2

4T2

6T3

1L1

2T1

K1

KM2

14

STOP

Q2

F1

13

13
15
A1
A2

13
14

K1

31
34

11
14
A1
RUN
RELAY
KM1

10
12

A1
EOA
RELAY

A1

KM2

A2

EOR
R

FAULT
R

RUN
R

18 17 16

15 14 13

12 11 10

U1 V1 W1
M
3~

(1) Above schemes are given for information purposes. Add additional emergency safety stop, if it is required for your application.
Remarks
1. Check coordination tables for proper selection of Breaker and Line contactor.
2. Control Voltage and Control Input voltage are from same source in above example. Please check manuals if you have different sources for
Control Voltage and Control input Voltage.
3. Semiconductor Fuses F are only required for Type 2 coordination. Please check coordination tables

D.82

16
18
A1
A2

ASTAT XT
Application wiring diagrams
Basic diagram in Inside Delta configuration with line and bypass contactors(1)
With Soft Start and Soft Stop
by push-buttons control

L1 L2 L3
Q1

KM1

T1

2
Q1

Q3

Q2
21

A1
13
FAULT
RELAY 15

6T3

4T2

2T1

BPC
GND

START 6

A1

SOFT STOP 5

STOP 4

COMMON 9

KM2

5L3

1L1

3L2

K1

START

K1

KM1

A1
A2

EOR
R

18 17 16

13
14

K1

31
34

11
14
A1
16
EOA
RELAY 18

A1
10
RUN
RELAY 12
KM1

A1
A2

FAULT
R

15 14 13

KM3

A1
A2

KM2

RUN
R

12 11 10

U1 V1 W1
M
PE
3~

A1
A2

Wiring diagrams

24

F1

14

STOP

K1

KM3

13

U2 V2 W2

B
(1) Above schemes are given for information purposes. Add additional emergency safety stop, if it is required for your application.
Remarks
1. C
 heck coordination tables for proper selection of Breaker and Line contactor.
2. C
 ontrol Voltage and Control Input voltage are from same source in above example. Please check manuals if you have different sources for
Control Voltage and Control input Voltage.
3. S
 emiconductor Fuses F are only required for Type 2 coordination. Please check coordination tables
4. W
 rong connection of the motor, or the ASTAT-XT when it is Inside-delta connected may seriously damage the motor or the ASTAT-XT. Please
check additional details given in the ASTAT XTs instruction manual.

C
D
E
F
G
H
I
X

D.83

ASTAT XT
Coordination Type 1
Combination with aM fuses - 415V
ASTAT-XT type
Rating (A)

Digital Soft Starters

Main Voltage
Up to 415VAC

8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
650
950
1100
1400

Cat. No.
-

QT10008_
QT10017_
QT10031_
QT10044_
QT10058_
QT10072_
QT10085_
QT10105_
QT10145_
QT10170_
QT10210_
QT10310_
QT10390_
QT10460_
QT10580_
QT10650_
QT10950_
QT11100_
QT11400_

ASTAT-XT type
Rating (A)
Main Voltage
Up to 415VAC

C
D
E

I
X

D.84

Rating (A)

CL/CK series

Iq (kA)

16
20
35
50
80
100
125
160
200
200
250
400
500
630
800
1000
2x630
2x800
2x800

CL00
CL02
CL04
CL06
CL07
CL08
CL09
CL10
CK75C
CK08C
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B
-

80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

Contactor
Type

Short-circuit
current

8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
650
950
1100
1400

Circuit Breaker

Cat. No.

Record Plus

Rating (A)

CL/CK series

Iq (kA)

QT10008_
QT10017_
QT10031_
QT10044_
QT10058_
QT10072_
QT10085_
QT10105_
QT10145_
QT10170_
QT10210_
QT10310_
QT10390_
QT10460_
QT10580_
QT10650_
QT10950_
QT11100_
QT11400_

FD63
FD63
FD63
FD160
FD160
FD160
FE160
FE160
FE160
FE250
FE250
FG400
FG400
FG630
FG630
FK1250
FK1250
FK1250
FK1600

16
40
50
63
80
80
125
160
160
160
160
400
400
630
630
1000
1000
1250
1600

CL45
CL06
CL06
CL06
CL07
CL08
CL10
CL10
CK85B
CK08
CK85
CK10C
CK12B
CK12B
CK13B
CK13B
-

65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
50
50
50
50

Contactor
Type

Short-circuit
current

Rating (A)

CL/CK series

Iq (kA)

16
20
35
50
80
100
125
160
200
200
250
400
500
630
800
1000
2x630
2x800
2x800

CL00
CL02
CL04
CL06
CL07
CL08
CL09
CL10
CK75C
CK08C
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B
-

80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

ASTAT-XT type

Short-circuit
current

Combination with aM fuses - 500V

F
G

Contactor
Type

Combination with Record Plus MCCBS - 415V

A
B

aM fuses

Rating (A)
Main Voltage
500 VAC

8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
650/820
950
1100
1400

aM fuses

Cat. No.
QT10008_
QT10017_
QT10031_
QT10044_
QT10058_
QT10072_
QT10085_
QT10105_
QT10145_
QT10170_
QT10210_
QT10310_
QT10390_
QT10460_
QT10580_
QT10650_
QT10950_
QT11100_
QT11400_

QT20008_
QT20017_
QT20031_
QT20044_
QT20058_
QT20072_
QT20085_
QT20105_
QT20145_
QT20170_
QT20210_
QT20310_
QT20390_
QT20460_
QT20580_
QT20820_
QT20950_
QT21100_
QT21400_

ASTAT XT
Coordination Type 2
Combination with semiconductor fuses - 415V
Contactor
Type

Short-circuit
current

Rating (A)
Main Voltage
Up to 415VAC

8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
650
950
1100
1400

Cat. No.

Bussmann type

CL/CK series

Iq (kA)

QT10008_
QT10017_
QT10031_
QT10044_
QT10058_
QT10072_
QT10085_
QT10105_
QT10145_
QT10170_
QT10210_
QT10310_
QT10390_
QT10460_
QT10580_
QT10650_
QT10950_
QT11100_
QT11400_

170M3808D
170M3810D
170M3813D
170M3814D
170M3814D
170M3815D
170M3816D
170M3817D
170M3817D
170M3819D
170M4864D
170M4864D
170M5814D
170M5820D
170M5816D
2x170M5814D
2x170M5816D
2x170M6892D
2x170M8555D

CL25
CL25
CL04
CL45
CL07
CL08
CL09
CL10
CK75C
CK08C
CK09B
CK95B
CK10C
CK11C
CK12B
CK13B
-

80
80
80
80
80
80
80
80
80
80
80
80
80
80
50
80
80
80
80

Semiconductor fuses(1)

Contactor
Type

Short-circuit
current

Cat. No.

Bussmann type

CL/CK series

Iq (kA)

QT20008_
QT20017_
QT20031_
QT20044_
QT20058_
QT20072_
QT20085_
QT20105_
QT20145_
QT20170_
QT20210_
QT20310_
QT20390_
QT20460_
QT20580_
QT20820_
QT20950_
QT21100_
QT21400_

170M3808D
170M3810D
170M3813D
170M3814D
170M3814D
170M3815D
170M3816D
170M3817D
170M3817D
170M3819D
170M4864D
170M4864D
170M5814D
170M5820D
170M5816D
2x170M5814D
2x170M5816D
2x170M6892D
2x170M8555D

CL25
CL25
CL04
CL06
CL07
CL08
CL09
CL10
CK75C
CK08C
CK09B
CK10C
CK10C
CK11C
CK12B
CK13B
-

80
80
80
80
80
80
80
80
80
80
80
80
80
80
50
80
80
80
80

Semiconductor fuses(1)

Contactor
Type

Short-circuit
current

Cat. No.

Bussmann type

CL/CK series

Iq (kA)

QT30008_
QT30017_
QT30031_
QT30044_
QT30058_
QT30072_
QT30085_
QT30105_
QT30145_
QT30170_
QT30210_
QT30310_
QT30390_
QT30460_
QT30580_
QT30650_
QT30950_
QT31100_
QT31400_

170M3808D
170M3810D
170M3813D
170M3814D
170M3814D
170M3815D
170M3816D
170M3817D
170M3817D
170M3819D
170M4864D
170M4864D
170M5814D
170M5820D
170M5816D
2x170M5814D
2x170M5816D
2x170M6892D
2x170M8555D

CL25
CL25
CL06
CL06
CL07
CL08
CK75C
CK75C
CK08B
CK08B
CK08B
CK10C
CK10C
CK12B
CK12B
-

50
50
50
50
50
50
50
50
50
50
50
50
50
50
30
50
50
50
50

Combination with semiconductor fuses - 500V


ASTAT-XT type
Rating (A)
Main Voltage
500 VAC

8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
650/820
950
1100
1400

QT10008_
QT10017_
QT10031_
QT10044_
QT10058_
QT10072_
QT10085_
QT10105_
QT10145_
QT10170_
QT10210_
QT10310_
QT10390_
QT10460_
QT10580_
QT10650_
QT10950_
QT11100_
QT11400_

Combination with semiconductor fuses - 690V


ASTAT-XT type
Rating (A)
Main Voltage
690 VAC

8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
650
950
1100
1400

Coordination tables

Semiconductor fuses(1)

ASTAT-XT type

A
B
C
D
E
F
G
H
I
X

(1) Semiconductor Fuses must be always used for Type 2 coordination

D.85

ASTAT XT
Dimensions and weights
Cat. No.: QTx0008U_ , QTx0017U_ , QTx0031U_ , QTx0044U_ , QTx0058U_ , QTx0072U_
158
By Pass
ABC

1L1, 3L2, 5L3

298

310

Digital Soft Starters

GND M5

2T1, 4T2, 6T3


130

D1

153

D2

Power terminal size (mm)


Dimensions

Cat. No

B
C

QTx0008U__
QTx0017U__
QTx0031U__
QTx0044U__
QTx0058U__
QTx0072U__

UL Certified units

D1
160
160
160
207
207
207

D2
182.5
182.5
182.5
229.5
229.5
229.5

Input

Bypass

Output

Weight Kg

1L1, 3L2, 5L3


16
16
16
16
16
35

A, B, C
16
16
16
16
16
35

2T1, 4T2, 6T3


16
16
16
35
35
35

4.2
4.2
5.3
6.7
6.7
6.7

Cat. No.: QTx0085U_ , QTx0105U_

D
GND M6

278
65.5
20

104.5
9

188
65.5

137

4
1L1, 3L2, 5L3

15

O 8.5

355

385

365

H
2T1, 4T2, 6T3

71.8

32.7

32.8

32.7

200
274

32.8

117

4
243

By Pass
ABC

X
Cat. No.

UL Certified units

D.86

QTx0085U__
QTx0105U__

Weight
15.2
15.2

ASTAT XT
Dimensions and weights
Cat. No.: QTx0145U_ , QTx0170U_

188

278
65.5
20

65.5

137

1L1, 3L2

355

Dimensions

365

O 8.5

385

15

99.5
9

GND M6

2T1, 4T2, 6T3

66.8

32.7

32.8

32.7

32.8

32.7

117

200
274

By Pass
ABC

4
244

B
Cat. No.

Weight

QTx0145U__
QTx0170U__

UL Certified units

15.2
15.2

Cat. No.: QTx0210N_ , QTx0315N_ , QTx0390N_ , QTx0460N_

D
15

160
43.5

125

O 10

125

54.2

30

182.2
5
By Pass
ABC

1L1, 3L2, 5L3

9.5

F
G

H4

H3

H2

H1

GND M8

H
125

125

2T1, 4T2, 6T3


5

182.2

43.5

299.4

380

X
Dimensions

Cat. No.

Non-UL Certified units

QTx0210N__
QTx0310N__
QTx0390N__
QTx0460N__

H1
455
455
455
555

H2
425
425
425
525

H3
414
414
414
528.5

Weight
H4
427
427
427
527

32.7
32.7
32.7
58.4

D.87

ASTAT XT
Dimensions and weights
Cat. No.: QTx0580N_

180
20

150

150

221.7
171.7

50.5

5
5

Digital Soft Starters

1L1, 3L2, 5L3

9.5

By Pass
ABC

40

O 13.5

50.5

150

615

600

542

528

615

655

GND M8

2T1, 4T2, 6T3


216.7

150

309.4

470

B
Cat. No.

Weight

QTx0580U__

Non-UL Certified unit

63.2

Cat. No.: QTx0650N_

D
E

180
20

150

150

221.7
171.7

50.5

5
5

1L1, 3L2, 5L3

9.5

By Pass
ABC

40

O 13.5

GND M8

615

600

542

528

615

655

G
H
I
50.5

150

150
470

2T1, 4T2, 6T3


216.7

309.4

X
Cat. No.

Non-UL Certified units

D.88

QTx0650N__

Weight
64.8

ASTAT XT
Dimensions and weights
Cat. No.: QTx0950N_

625

292.4

195

195

234.5

640

626.5

Dimensions

659

9.5

2T1, 4T2, 6T3

10

1L1, 3L2, 5L3


10
10

114

114

50

17.5

245

114

74.7

45

O10.5

20

45

GND
M8

80

440

Remarks
1. This unit must be operated with a bypass contactor
2. Add space for current transformers (supplied separately from the main unit) and bus
bars for preparation for bypass
Approximate current transformers dimensions: W=240mm, H=130mm, D=90mm

Cat. No.

Non-UL Certified unit

QTx0950N__

B
Weight
86.7

Cat. No.: QTx1100N_ , QTx1400N

D
131.5

230

230

230

230

1L1, 3L2, 5L3

45
45

10

29

165

O10.5
O9

16.5

94

20

80

230

GND M10

712

786

1100

H
9
8

230

230

45

2T1, 4T2, 6T3

20

80
191.5

230

230
723

Remarks
1. Units must be operated with a bypass contactor
2. Add space for current transformers (Supplied separately from main unit) and bus bars
for preparation for bypass
Approximate current transformers dimensions:
W=240mm, H=130mm, D=90mm. (for 1100A unit, Cat Numbers QTx1100N__
W=270mm, H=155mm, D=90mm. (for 1400A unit, Cat Numbers QTx1400N__

Non-UL Certified unit

45

O10.5

266

10
376.8

X
Cat. No.
QTx1100N__
QTx1400N__

Weight
169.8
175.5

D.89

ASTAT XT
Dimensions and weights
Cat. No.: QTx0210U_ , QTx0315U_ , QTx0390U_

592
187.5

292.4
187.5

234.5

486.5

500

Digital Soft Starters

9.5

30

26

O10

44

By Pass

141

44

141

44

2T1, 4T2, 6T3

1L1, 3L2, 5L3

89

64.2
GND M8

5
160.2

B
Cat. No.

Weight

QTx0210U__
QTx0310U__
QTx0390U__

UL Certified unit

32.7
32.7
32.7

Cat. No.: QTx0460U_

D
625
195

292.4
234.5

195

9.5

659
818

626.5

640

GND
M8

25

25

50

2T1, 4T2, 6T3


13

1L1, 3L2, 5L3


25
25

O10
13

65

130

74.2
65

130

65

80

6
155.2

Cat. No.

UL Certified unit

D.90

QTx0460U__

By Pass
ABC
6

Weight
61.8

ASTAT XT
Dimensions and weights
Cat. No.: QTx0580U_ , QTx0820U_
625
195

292.4
234.5

195

659
818

640

Dimensions

626.5

9.5

GND
M8

25

25

50

2T1, 4T2, 6T3


13

1L1, 3L2, 5L3


25

By Pass
ABC

13

25

74.2
195

195

77

73.5

6
155.2

B
Cat. No.

UL Certified unit

QTx0580U__
QTx0820U__

Weight
69.5
69.5

C
D
E
F
G
H
I
X

D.91

48962

GE Consumer & Industrial


Power Protection

Power Protection (formerly GE Power Controls),


a division of GE Consumer & Industrial,
is a first class European supplier of
low-voltage products including wiring
devices, residential and industrial electrical
distribution components, automation
products, enclosures and switchboards.
Demand for the companys products
imagination
at work
comes from,GE
wholesalers,
installers,
panel-board builders, contractors, OEMs
and utilities worldwide.

GE imagination at work

www.ge.com/ex/powerprotection
www.ge.com/eu/powerprotection

GE imagination at work

GE imagination at work

GE imagination at work

GE POWER CONTROLS Ltd


Houghton Centre
Salthouse Road
Northampton NN4 7EX
United Kingdom

Customer Service
Tel. 0800 587 1251
Fax 0800 587 1239
E-mail: gepcuk@gepc.ge.com

GE CONSUMER & INDUSTRIAL HUNGARY


Vci t 77
H-1340 Budapest
Hungary
Customer Service
Tel. +361 447 6046
Fax +361 447 5060
E-mail: mea.export .consind@ge.com
Net: www.gepowershop.com

GE imagination at work

GE CONSUMER & INDUSTRIAL


POWER PROTECTION
Nieuwevaart 51
B-9000 Gent
Belgium
Tel. +32/9 265 21 11
Fax +32/9 265 28 00
E-mail: gepcbel@gepc.ge.com

GE imagination at work
680804
Ref. C/4601/E/EX 2.5 Ed. 05/09
Copyright GE Consumer & Industrial 2009