Documente Academic
Documente Profesional
Documente Cultură
CS 4220 Process
1. Download Mix Design / Batcher Mixer Excel spreadsheet files from PENNDOTs web
site www.dot.state.pa.us / General Information / Publications / Forms, Publications
and Maps or PACAs web site www.pacaweb.com
2. Open the Mix Design File and save it as your master file.
3. Enter information on the mix design form. The cells with a red corner have prompts
built in to the program.
4. Use Save As and name the file with the mix design number. 04-3A012 First 2 digits
are the year. Dash. Next 2 digits are the class: 1C to 3A. The last 3 spaces are the
numbers or letters used to designate the mix.
5. E-mail the mix design files to the appropriate District Materials Unit
RA-PDDistrict7-0mat@state.pa.us with the request to use the mix designs.
6. The District Materials Unit will evaluate the mix design information and reply to the
e-mail stating if the mixes can be used.
7. The producer is to keep (save, print, etc) the mix design information and the District
Materials Engineers e-mail reply.
I.
Open the Batcher Mixer File and save it as your master file.
II.
Use as appropriate during production. Paper copies of the Batcher Mixer slip
will need to be sent to the projects because of limited email capability.
TR-4221A (02-09)
Material Class:
Date:
JMF No.:
District:
SR/WO:
ECMS No.:
Sec/Segmt:
Contractor:
Concrete Producer:
Location:
Supplier Code:
Material
Product Name
FA No:
ASTM Type
Sp. Gr.
Supplier Code:
Cement
3.15
Pozzolan 1
2.40
Pozzolan 2
A57
2.78
Coarse Agg. #2
A8
2.78
Fine Agg.
2.61
WTRMIX
Admixture
Lab No.
Asr.
2.20
Coarse Agg. #1
Water
Abs.
AEA
Mfg Dose/cwt
Oz/cwt
36
Min
Max
Admixture
Oz/cwt
18
15
Admixture
Oz/cwt
18
12
Admixture
Oz/cwt
18
% Sol
wt/gal
% Sol
wt/gal
0.0
0.0
0.43
0.01
hours
psi(avg)
days
psi(avg)
days
psi(avg)
days
psi(avg)
Mix Number
W/C Ratio by (wt)
Cement (lbs)
Pozzolan 1 (lbs)
Pozzolan 2 (lbs)
Total Cementitious
Coarse aggregate 1 (lbs)
Coarse aggregate 2 (lbs)
Total Coarse aggregate (lbs)
Fine aggregate (lbs)
Total water (lbs)
Admixture water (lbs)
Mix water (lbs)
Admixture solids/yd (lbs)
Total (lbs)
Unit weight (lbs/cu. ft.)
Coarse aggregate vol. (cu.ft.)
Total water (Gal)
Mix water (Gal)
1
0.430
400
100
100
600
1388
347
1735
1273
258
2
0.420
400
100
100
600
1388
347
1735
1288
252
3
0.410
400
100
100
600
1388
347
1735
1304
246
4
0.400
400
100
100
600
1388
347
1735
1320
240
5
0.390
400
100
100
600
1388
347
1735
1335
234
258
0
3865
143.16
10.00
31.0
31.0
252
0
3875
143.52
10.00
30.3
30.3
246
0
3885
143.88
10.00
29.5
29.5
240
0
3894
144.24
10.00
28.8
28.8
234
0
3904
144.59
10.00
28.1
28.1
Designed by:
Date:
Date:
Reviewed by Contractor:
Date:
Date:
Page 1 of 4
TR 4221A (02-09)
Matl. Class:
Date:
District:
ECMS:
Project or Plant:
1"
3/4"
1/2"
3/8"
#4
#8
#16
#30
#50
#100
A57
A8
A
FM
Maximum Density:
lbs/ft, ssd
6.00
% solids:
CA Volume:
(Bulletin 5 method)
(Bulletin 5 method)
Wt/Volume calculations
W/C Ratio:
0.43
MIX #
Cement
(type)
2.04
feet
x S.G. x 62.4
400
lbs
Pozzolan 1
(type)
0.67
feet
x S.G. x 62.4
100
lbs
Pozzolan 2
(type)
0.73
feet
x S.G. x 62.4
100
lbs
C. Agg. #1
A57
(grading)
8.00
feet
1 CF 1
LBS
x S.G. x 62.4
=
8
1388
CF
lbs
C. Agg. #2
A8
(grading)
2.00
feet
1
1
x S.G. x 62.4 =
2
347
CF
lbs
10.00 feet
1735
lbs
4.13
feet
258
lbs
1.62
feet
0
lbs
1273
lbs
3865
lbs
Total C. Agg
Water
31.0
% Air
6.0
(Gals.)
% / 100 x 27.0
x S.G. x 62.4
Admix (Solids, if =
Nec.)
SUBTOTAL =
F. Agg.
27.0 - (subtotal)
TOTALS =
Temperature:
Concrete:
Initial Testing:
Slump:
At Pt of Placement: Slump:
Strength
F'c, (compressive), psi
F'c, (compressive), psi
DAYS/HRS
F
in.
in.
1
19.19 feet
7.81
feet
x S.G. x 62.4
27.00 feet
Air:
Air Content
Air Content
2
F
%
%
AVE
0
0
DAYS
AVE
0
0
TR 4221A (02-09)
Matl. Class:
Date:
District:
ECMS No.:
Wt / Volume calculations
0.42
W/C Ratio:
MIX #
Cement
(type)
2.04
feet
x S.G. x 62.4
400
lbs
Pozzolan 1
(type)
0.67
feet
x S.G. x 62.4
100
lbs
Pozzolan 2
(type)
0.73
feet
x S.G. x 62.4
100
lbs
C. Agg. 1
A57
(grading)
8.00
feet
x S.G. x 62.4
1388
lbs
C. Agg. 2
A8
(grading)
2.00
feet
x S.G. x 62.4
347
lbs
(Gals.)
4.04
feet
x S.G. x 62.4
252
lbs
lbs
1.62
feet
SUBTOTAL =
19.09
feet
7.91
feet
1288
lbs
TOTALS =
27.00
feet
3875
lbs
Water
30.3
% Air
F. Agg.
% / 100 x 27.0
27.0 - (subtotal)
Admix (Solids, if =
Nec.)
x S.G. x 62.4
Wt / Volume calculations
0.41
W/C Ratio:
MIX # 3
Cement
(type)
2.04
feet
x S.G. x 62.4
400
lbs
Pozzolan 1
(type)
0.67
feet
x S.G. x 62.4
100
lbs
Pozzolan 2
(type)
0.73
feet
x S.G. x 62.4
100
lbs
C. Agg. 1
A57
(grading)
8.00
feet
x S.G. x 62.4
1388
lbs
C. Agg. 2
A8
(grading)
2.00
feet
x S.G. x 62.4
347
lbs
(Gals.)
3.94
feet
x S.G. x 62.4
246
lbs
lbs
% / 100 x 27.0
1.62
feet
SUBTOTAL =
18.99
feet
8.01
feet
1304
lbs
TOTALS =
27.00
feet
3885
lbs
Water
29.5
% Air
F. Agg.
27.0 - (subtotal)
Admix (Solids, if =
Nec.)
x S.G. x 62.4
TR 4221A (02-09)
Matl. Class:
Date:
District:
ECMS No.:
Wt/Volume calculations
0.40
W/C Ratio:
MIX #
Cement
(type)
2.04
feet
x S.G. x 62.4
400
lbs
Pozzolan 1
(type)
0.67
feet
x S.G. x 62.4
100
lbs
Pozzolan 2
(type)
0.73
feet
x S.G. x 62.4
100
lbs
C. Agg. 1
A57
(grading)
8.00
feet
x S.G. x 62.4
1388
lbs
C. Agg. 2
A8
(grading)
2.00
feet
x S.G. x 62.4
347
lbs
(Gals.)
3.85
feet
x S.G. x 62.4
240
lbs
lbs
1.62
feet
SUBTOTAL =
18.90
feet
8.10
feet
1320
lbs
TOTALS =
27.00
feet
3894
lbs
Water
28.8
% Air
F. Agg.
% / 100 x 27.0
27.0 - (subtotal)
Admix (Solids, if =
Nec.)
x S.G. x 62.4
Wt/Volume calculations
0.39
W/C Ratio:
MIX # 5
Cement
(type)
2.04
feet
x S.G. x 62.4
400
lbs
Pozzolan 1
(type)
0.67
feet
x S.G. x 62.4
100
lbs
Pozzolan 2
(type)
0.73
feet
x S.G. x 62.4
100
lbs
C. Agg.
A57
(grading)
8.00
feet
x S.G. x 62.4
1388
lbs
C. Agg.
A8
(grading)
2.00
feet
x S.G. x 62.4
347
lbs
Water
28.1
(Gals.)
3.75
feet
x S.G. x 62.4
234
lbs
lbs
% Air
1.62
feet
SUBTOTAL =
18.80
feet
8.20
feet
1335
lbs
TOTALS =
27.00
feet
3904
lbs
F. Agg.
% / 100 x 27.0
27.0 - (subtotal)
Admix (Solids, if =
Nec.)
x S.G. x 62.4