Sunteți pe pagina 1din 7

Transponder Technologies Pty Ltd

A.B.N. 82083558178
2 Hamra Drive
Export Park
Adelaide Airport, South Australia 5950

T6 Controller
Configuration String Reference

Information contained in this document is subject to change without notice and Transponder Technologies
does not guarantee that the content is free of typographical error. No part of this document may be
reproduced or transmitted in any form or by any means without the express written permission of
Transponder Technologies.

Document Number
Original File Name

7
D00067
Document Version
7
Number of pages
D00067-7 T6 Controller Configuration String Reference.docx

T6 Controller - Configuration String Reference

CHANGE HISTORY
Doc Ver

Date

Firmware Ver*

18-Jul-07

03024

15-Feb-08

03046

13-May-08

03057

06-Dec-10

03057

23-Nov-11

05071

6
7

1-Feb-12
8-Oct-12

05075
05105

Change Details
- First release of new document
- Added TT3000 Site Monitor to digit A.1
- Added XML tank status output to digit A.1
- Added XML tank status output to digit B.8
- Changed definition of values 2 & 4 in digit B.12
- Added RQYS custom behaviour to digit A.8
- Added Print settlement report option to digit B.5
- Added Drystock entry at TT3000 option to digit B.6
- Added Expiry date & grade ignore option to digit B.11
- Changed description of option B.4
- Doc updated to new latest TT template
- Added value 4 to digit A.1
- Updated description of value A.9.8
-Added value 3 to digit A6
-Added POS protocol, container seal prompt

* Version of new firmware build guaranteed to have listed changes in configuration options implemented
but is not necessarily when the change was first implemented.

FEEDBACK
As part of Transponder Technologies Continued Improvement Program we encourage any feedback for
this document to be emailed to: support@ttonline.com.au
All documentation becomes dated and at Transponder Technologies we are continually evolving our
products and documentation accordingly. Unintentional technical or typographical errors are periodically
corrected in later revisions.
Our current documentation convention is DXXXXX-1, where XXXXX is the document number and
1 is the revision level.

DISCLAIMER
All endeavours have been made to ensure information contained in this document is correct and accurate
at the time of release. Transponder Technologies does not accept liability for any errors, omissions, or the
use of information within this document.

NAVIGATING PDF VERSION OF DOCUMENT


When reading the PDF version of this file using Acrobat Reader, all sections are directly accessible via
the Bookmarks facility of Acrobat Reader to make navigation through the document easier and faster.
Additionally, any cross-reference in the document (where the text reads see section 0 for example) can
be clicked on to directly move the document directly to the referenced section.

Doc No. D00067 Ver 7

COMMERCIAL-IN-CONFIDENCE

Page 2 of 7

T6 Controller - Configuration String Reference

Doc No. D00067 Ver 7

COMMERCIAL-IN-CONFIDENCE

Page 3 of 7

T6 Controller - Configuration String Reference

1. Configuration String A
Left most digit is number 1, right most digit is number 12. All unused digits should be set to 0.
1

12

000000000000
Digit

Value
1
2
3
4
5
6
7
8

Short Description
Site totals monitor
Transac with PartnerTech keypad/card reader
TT3000 or TT4000 DCA
Transac with Genovation keypad/card reader
FC6000
FC6000 with customer display
FC6000 with receipt printer
FC6000 with receipt printer and customer display

1
2
3
4
5
6
7
8
9

Inhibit no-flow timeout for card transactions


Limit to one transaction at a time per card
Dollar limit per transaction on local/white cards

2
3
4
5

Show card fuel totals on shift and date-range reports


Show discount totals on shift and date-range reports
Show card and discount totals on shift and date-range reports
Show card fuel totals for indoor/outdoor terminals

2
3
5
6

Print litres only on reports and receipts


FC6000 special payment logging mode
Disable "Receipt unavailable" message for DCA
Disable "Receipt paper low" message for DCA

4
5
6
7
8

Record system snapshot daily at midnight


Record system snapshot only when tank dip or pump meter is entered
Record system snapshot when OPT EFT PIN-pad settles
Prompt to end day when rolling shift on FC6000
Prompt to end day and report shift totals from IPT

Litre ration limit on local/white cards


Loyalty card mandatory for EFT transactions
Suppress rate when printing discount amount on receipt

Doc No. D00067 Ver 7

COMMERCIAL-IN-CONFIDENCE

Page 4 of 7

T6 Controller - Configuration String Reference

1
2
3
4
5
6
7
9

Prompt for dollar preset


Prompt for litre preset
Big+dual cardbase file mode. Full auditing in second buffer
Prompt for litre preset and reject if 0 (=unlimited) entered
Big cardbase file mode
Dual cardbase file mode
Dual cardbase file mode will full auditing in first buffer
Very big cardbase file mode

1
2
3
5
6
7
8
9

Prompt for User ID - mask entry


Prompt for User ID
Prompt for User ID using "Driver ID" message
Prompt for User ID. Accept all values entered (i.e. don't validate)
Prompt for User ID. Prompt per card.
Prompt for User ID using "Present Vehicle ID" message.
Prompt for User ID using "Present User ID" message.
Prompt for User ID using "Present User ID" message before card ID prompt.

1
2
4
6
7

Prompt for odometer regardless of access ID flag.


Never prompt for odometer regardless of access ID flag.
Prompt for work hours.
Prompt for vehicle number
Prompt for odometer with range checking

1
2
3
5
6
7
8
9

ID reader interfaces via audit printer port


Special card number length processing: Starcard=8, PEC=7, Shell=8 digits
Special card number length processing: PEC=9 digits
Wiegand 27bit format
Prompt container seal code
Authorisation via manual entry of Vehicle number

10

2
3

Limited/positive validation mode for (primary) card/access ID list


Extended/negative validation mode for (primary) card/access ID list

11

2
5
6
7
9

FC6000 - do not prompt for method of payment


FC6000 - do not allow manual card number entry
FC6000 - round currency to nearest 5c and print "Total includes GST" on receipts
FC6000 - round currency and mark GST items on receipt with "*"
As per value '7' but receipt printing option as per MOP setup rather than prompted

12

1
2

Magnetic swipe card reader is Track 1 type


Magnetic swipe card reader is Track 2 type

Doc No. D00067 Ver 7

COMMERCIAL-IN-CONFIDENCE

Page 5 of 7

T6 Controller - Configuration String Reference

2. Configuration String B
Left most digit is number 1, right most digit is number 12. All unused digits should be set to 0.
1

12

000000000000
Digit

Value
2
3
4
5

Short Description
EFT receipt header - print line 2 of receipt details
EFT receipt header - print line 3 of receipt details
EFT receipt header - print line 4 of receipt details
EFT receipt header - print all lines of receipt details

0
1
2
3
4

0 decimal places price per unit. 0 decimal places total price.


1 decimal places price per unit. 0 decimal places total price.
2 decimal places price per unit. 1 decimal place total price.
3 decimal places price per unit. 2 decimal places total price.
2 decimal places price per unit. 2 decimal places total price.

0
1
2

Volume in 'Litres'
Volume in 'Gallons'
Handle Chinese variant of Gilbarco dispenser

0
1
2
3
4

Host communications: Standard AT modem


Host communications: Port speed locked at 38400 baud. No modem detection or initialisation.
Host communications: Cybertec modem at 38400 baud.
Host communications: Cybertec modem at 57600 baud.
Host communications: Port speed locked at 57600 baud. No modem detection or initialisation.

1
2
3
4
5
6
7
8
9

Old CAS software mode


Caltex OPT mode
EFT surcharge prompt over-ride
Caltex OPT mode with normally closed emergency stop detection circuit
T&C prompt for EFT transactions
Single pump mode
Print settlement report at OPT when EFT PIN-pad settlement occurs.
Overwrite undeleted transactions
Australian Department Of Defence TT3000SC mode.

1
2
3
4
5
6
7
8

Email Mark 3 console emulation mode at 9600 baud.


Gilbarco T24 console emulation mode.
Gilbarco T24 console emulation mode with handshaking.
Email Mark 3 console emulation mode at 4800 baud.

Epson combined receipt printer & customer display attached to FC6000


Authorise pump even if nozzle out.

Doc No. D00067 Ver 7

COMMERCIAL-IN-CONFIDENCE

Page 6 of 7

T6 Controller - Configuration String Reference


9

Epson receipt printer attached to FC6000

1
2
3
4
5

Registered users mode


FC6000 PLU mode
FC6000 PLU mode with additional field appended to transaction record
Epson combined receipt printer & customer display attached to FC6000 (Same as B6=6)
Prompt for litre preset and reject if 0 (=unlimited) entered (Same as A6=4)

1
2
3
4
5
6
7
8
9

Prompt for engine hours


Prompt for engine hours with range checking
FC6000 satellite card reader/keypad
Enable price sign interface - Ausport protocol
Quest IPT/gateway
iButton reader via serial port for FC6000
Enable price sign interface - Bever Innovations protocol
Enable interface to USB file transfer hardware - Vinculum protocol/POS protocol (FC6000 only)
Enabled forecourt communications channel 3 using audit printer port

2
3
4

Limited/positive validation mode for secondary card/access ID list


Extended/negative validation mode for secondary card/access ID list
Preclude drystock from being purchased via local card at FC6000

10

1
2
3
4
5
6
7
8
9

Dont allow Prepay card transaction if card balance is less than $1.00
Prompt for security contact
Refueller mode
Plant refueller mode
Handle pumps as if they all have preset valves and support limit messages
Refueller mode with single authorisation
Deadman switch at CAS mode
Bay authorisation mode
Email pumps operating Gilbarco protocol

11

1
2
3

Ignore expiry date encoded on card


Ignore grade restrictions encoded on card
Ignore expiry date and grade restrictions encoded on card

12

1
2
3
4
5
8

OIML checking FC6000 mode


Upsonic UPS via RS232 interface connected to FC6000
OIML checking FC6000 mode and Upsonic UPS connected
Sola UPS via voltage free contacts connected to FC6000
OIML checking FC6000 mode and Sola UPS connected
Disallow stacking of sales on FC6000

Doc No. D00067 Ver 7

COMMERCIAL-IN-CONFIDENCE

Page 7 of 7

S-ar putea să vă placă și