Sunteți pe pagina 1din 6

3/63+05.

;(52
4000L
ho Lding Tank

Item
Item
Itemno.
no.

Qty
Qty
Qty

11

11

Description
Description
Description
Holding
Tank
Base
factory
Holding
Tank
Base
factory
Holding
Tank
Base
factory
assembled
including
factory
ttedtted
assembled
including
factory
assembled
including
factory
tted
reinforcing
ring
(item
12) 12)
and
tank
reinforcing
ring
(item
reinforcing
ring
(item
12)and
andtank
tank
base
predrilled
to nominal
base
extensions
predrilled
to
baseextensions
extensions
predrilled
tonominal
nominal
capacity
4000L
capacity
4000L
capacityofof
of
4000L
(items
16,17,19,
(items
20,20,
21)21)
(items16,17,19,
16,17,19,
20,
21)

22

11

Tank
Tank
Lid
TankLid
Lid

33

11

Manhole
Manhole
Cover
ManholeCover
Cover

44

22

Inspection
Cover
Inspection
Cover
Inspection
Cover

Accessory
Contents
Accessory
Accessory Kit
Kit Contents
Contents
55

11

Inlet
Inlet
T-Junction
InletT-Junction
T-Junction

88

66

Manhole
Screws
Manhole
Self
Tapping
Screws
ManholeSelf
SelfTapping
Tapping
Screws
10g
316
Stainless
Steel
10g
Steel
10g316
316Stainless
Stainless
Steel

99

88

T-Junction
Self
Tapping
Screws
T-Junction
Self
Tapping
Screws
T-Junction
Self
Tapping
Screws
10g
Steel
10g
316
Stainless
Steel
10g316
316Stainless
Stainless
Steel

10
10
10

88

Lid
Lid
Bolt,Washer,Nut
LidBolt,Washer,Nut
Bolt,Washer,Nut
316
Stainless
Steel
M6
Steel
M6316
316Stainless
Stainless
Steel

11
11
11

22

Bafe
Bolt,Washer,Nut
Bafe
BafeBolt,Washer,Nut
Bolt,Washer,Nut
M6
Steel
316
Stainless
Steel
M6316
316Stainless
Stainless
Steel

14
14
14

22

Bafe
Bolt,Washer,Nut
Bafe
Extension
Bolt,Washer,Nut
BafeExtension
Extension
Bolt,Washer,Nut
316
Stainless
Steel
M6
Steel
M6316
316Stainless
Stainless
Steel

22
22
22

88

Anchor
Rope
Anchor
AnchorRope
Rope

23
23
23

11

Installation
Instructions
Installation
Instructions
Installation
Instructions

Septic Tank & Holding Tank

Installation guide

Dimensions
Dimensions
Nominal
(mm)
DimensionsNominal
Nominal(mm)
(mm)
AA Overall
Overall
tank
height
height
Overalltank
tank
height

2410
2410
2410

BB Liquid
Liquid
depth
level
level
Liquiddepth
depth
level

1732
1732
1732

CC TTank
Tank
rim
invert
invert
of inlet
of
Tankrim
rimtoto
to
invert
of inlet
inlet

385
385
385

D
roof
liquid
level
DD Under
Under
toto
liquid
level
Underroof
roof
to
liquid
level

540
540
540

EE
Note:
Note:
ss"AFmEAND
Bafe
and
Outlet
T-Junction
not required in a Hholding
tank.
NDD/U
/UTLE
/U
TLETTT
TLE
T *U
*UNCT
NCTI
TIONNOTREQUIREDINAHO
LDINGTAN
LDI
TANK
K
"AFmEAND/UTLETT *UNCTIONNOTREQUIREDINAHOLDINGTANK
s0
Plumber
to supply and install discharge pipe.
ss0LUMBERTOSUPPLYANDINSTALLDISCHARGEPIPE
0LUM
LUMBERTOSUPPLYANDINSTALLDISCHARGEPIPE
s(OLDINGTANKS
Holding tanks
must
only
be pumped out half way
s(OLDINGTANKSMUSTONLYBEPUMPEDOUTHALFWAY
NKSMUST
MUSTONL
ON YBEPUMPEDOUTHALFWAY
s,TANKBASESARESUPP
4000L tank bases are supplied
factory assembled
s,TANKBASESARESUPPLIEDFACTORYASSEMBLED
UPPLIEDFACTORYASSEMBLED
s!RISERMUSTNOTBElT
A riser must not be lTTED
tted
to
s!RISERMUSTNOTBElTTEDTO,TANK
TEDTO,TA
TO 4000L tank
ANK

Max
Maximu
imum
mcover
ccover
cove
over
tinlet
o inlet
iinlet
inle
nlet
t pipe
ppipe
ipe
Maximum
Maximum
cover
tor to
pipe
Maximum
to

430
430
430

G
Overall
diameter
G Overall
Overalldiameter
diameter

1998
1998
1998

H
Tank
base
ground
ground
levellevel
H TTank
Tankbase
basetoto
to
ground
level

2272
2272
2272

Capacity
Capacity
Capaci
acity
aci
ty
Capacity

4000L
4000L
4000L

Weight
Weight
Weig
ght
Weight

159kg
159kg
k
159kg

FF

DD

CC
Liquid
Liq
uid Le
Level
v
vel
Liquid
Level

AA
HH
BB
Dis
Discharge
Discha
charge pipe
Discharge
pipe
(by
plumb
um er)
plumber)
(by pl
plumber)

11404 11/11

400
0 Septic
0L
Septi
Sep
tic Tank
TTank
ank
nk w/
RRiser
Ri
ser
er
4000L
4000L
Septic
w// Riser

For more information on installation and


technical specications, please visit

www.reln.com.au

3200L Holding Tank


3200L Septic Tank with Riser
3200L Holding Tank with Riser
4000L Septic Tank
4000L Holding Tank

GG

Ground
und Le
Level
vel
Ground
Level

3200L Septic Tank

Ho
HHolding
ldi
ding
ng Tank
TTank
a w/
ank
Ri
ser
4000L
4000L Holding
w/ Riser
Riser

;(52)(:,(::,4)3@053,;6<;3,;1<5*;065:

9,35:LW[PJ;HUR /VSKPUN;HUR0UZ[HSSH[PVU0UZ[Y\J[PVUZ

1. On inlet side of tank base t Inlet T-Junction. Apply silicone sealer to the ange of the T-Junction and secure with supplied four (4) stainless steel self-tapping
screws. (Fig 4 shown for 3200L)
RELN Septic Tanks and Holding Tanks are to be installed, by a licensed plumber, as per these instructions and local authority requirements.

2. On outlet side of tank base t Outlet T-Junction. Apply silicone sealer to the ange of the T-Junction and secure with supplied four (4) stainless steel
self-tapping screws. (Fig 5 shown for 4000L)

RELN Septic Tanks and Holding Tanks are supplied with inlet and outlet holes drilled to the required location.
RELN Septic Tanks and Holding Tanks are approved to the requirements of the Australian Standard AS/NZS1546.1:2008 On-site domestic wastewater treatment
units Septic tanks. Lic SMK1651

707,*655,*;065
1. Connect 100mm PVC sewer pipe into Inlet T-Junction. Glue inlet pipe to T-Junction with PVC plumbers glue.

Approvals and additional information on Septic Tank operation and maintenance can be obtained from www.reln.com.au

2. Connect 100mm PVC sewer pipe into Outlet T-Junction. Glue outlet pipe to T-Junction with PVC plumbers glue.

;(52(5*/6905.

,?*(=(;065

1. Tie anchoring ropes (8) to the pre-drilled lugs in the rim of the tank. Leave the looped end to hang free.

1. Excavate site for installing tank in ground as per building code and local authority
requirements. Ensure adequate pipe fall to inlet of tank and from the tank outlet to
the transpiration bed or holding tank. Additionally, septic tanks are to be sited:
away from building foundations,
away from trafc areas, both vehicular and pedestrian,
away from or fenced off from animal stock pastures and areas.

2. Place four durable anchoring beams (not included) through the looped ends of the ropes.
3. Anchor beams can be made from 100mm PVC sewer pipe (plumber to supply) and should be 2 metres long and positioned to exceed the tanks extremities.
(Fig 6 & 7)
Approx
2.0m

2. Refer to the tank dimensions diagrams for correct levels.


3200L Tanks need approx 2.0m deep excavation (Fig 1)
4000L/3200L Tank complete with Riser need approx
2.4m deep excavation (Fig 2)
(exact depth will vary due to land fall and depth of bedding sand)

(Fig 1)

(Fig 4)

(Fig 5)

(Fig 6)

(Fig 7)

3. Do not bury tank lid. Manhole cover and inspection covers must be nished above
normal ground level to allow ongoing tank inspection and maintenance.
4. In the base of the excavation prepare a level 50mm bed of compacted sand
or soft compactable ll, free of large and/or sharp objects to allow levelling
of the tank base.
5. Carefully lower tank base into excavation - do not drop.

Approx
2.4m

6. Align inlet and outlet with pipe trenches. Ensure tank base is level with lid off.

;(52)(:,(::,4)3@)(--3,
1. Where a bafe is required (check your state/local regulations), insert the
bafe as follows.

(Fig 2)

Position the bafe in the location lugs in the base of the tank
In tank bases with a factory installed reinforced structural brace ring:
Lower the bafe into the centre of the tank
From inside the tank tilt the bafe so the bottom of the bafe is located
into the retaining pins in the base of the tank
Push the bafe into a vertical position
Ensure the bafe is seated on the reinforced structural brace ring and
rmly located in the base pins.
2. Drill and x in marked position using supplied two (2) stainless steel bolts, nuts and
washers provided.
3. For 4000L Tanks, clip the additional bafe extension on top of the main bafe and
screw into place where indicated using two (2) stainless steel bolts, nuts and
washers supplied. (Fig 3)

(Fig 3)

Septic Tank & Holding Tank Installation Guide

Septic Tank & Holding Tank Installation Guide

9,353:,7;0*/63+05.;(52:*6473,;,>0;/90:,9

3:,7;0*/63+05.;(52:

In sites where more fall is required from the exit point of the sewer line from the house to the septic tank, a riser can be used on a 3200L septic tank and holding
tank. This tank must be ordered complete with riser and will be supplied with a factory installed reinforced structural brace ring (Fig 8). The plumber installing
the septic tank is to assemble the riser ring onto the tank base. Only one riser ring can be used. Riser rings must not be assembled to tank bases that do not
have a factory tted reinforced structural brace ring.

4000L Septic Tanks and Holding Tanks are supplied with a fully assembled base
including the factory installed and sealed reinforced structural brace ring and the
additional base segments. (Plumber installs T-Junctions & Bafe).

Riser
(::,4)305.90:,9905.

30+05:;(33(;065

1. Seal the riser ring to the tank with the provided black mastic sealing strip.

1. Use supplied M6 Bolts to assemble lid to the assembled tank base (do not use self
tapping screws).

2. Cut four (4) strips 390mm long for the vertical sealing faces of the riser ring.

2. Apply a sealing bead of silicone in the top lip of the assembled tank base.

3. Apply a sealing strip to the vertical face ensure sealing strips cover the full length of
the vertical faces to provide a seal between each riser segment face. Remove paper
strip. Ensure a small protrusion of the seal at the bottom edge of the ring (3mm).

3. Place lid onto assembled tank base aligning the dowel pin in the tank base
assembly (Fig 9) with the corresponding dowel hole in the lid. This aligns the
inspection covers above the inlet and outlet pipes.

4. Bolt each riser segment panel together with the 12 supplied M8x40 stainless steel
bolt, washer and nuts. Use a washer on each side of the bolt. Securely tighten
bolts. This completes assembly of the ring segments.

4. Drill and x lid in position with the supplied eight (8) M6 x 30 stainless steel bolts,
washers and nuts.

5. On the tank base roll the remaining sealing strip into the channel lip rim of the tank
base, ensuring even coverage. Remove paper strip.

5. Apply a sealing bead of silicone to lid recess for manhole cover.


Bafe

6. The sealing strip is mouldable. Mould the ends of the sealing strip together to
create a single complete circular seal.

6. Secure manhole cover in position with six (6) stainless steel self-tapping
screws provided.
7. Apply a sealing bead of silicone to lid and secure the two inspection covers.

7. Identify the riser segment panel with the location lug. (Fig 9)
8. This riser segment and lug is positioned directly above the inlet pipe and aligns with
the lug in the tank base (Fig 10) and the inlet inspection point in the lid.

+0:*/(9.,707,/63+05.;(52653@

9. Place and align the assembled riser ring on top of the tank base.

1. Discharge pipe by plumber (Fig 13). Ensure discharge pipe hole does not cut
through lid strengthening ribs. (Fig 14)

10. Ensure correct positioning of riser ring dowel hole on the tank base
location dowel. (Fig 11)

2. Fasten discharge pipe to lid using 316 stainless steel screws.

(Fig 8)

11. With an M8 bit, drill and x riser ring in position with 16 provided M8x50 stainless
steel bolts, washers and nuts. Use a washer on each side of the bolt. Securely
tighten bolts. Do not use self tapping screws!

(Fig 12)

3. Seal discharge pipe to lid with silicone.


4. Ensure maximum length of discharge pipe is half of tank depth. (Holding tanks must
only be pumped out half way.)
5. Discharge pipe connections must be positioned for easy pump-out vehicle access.

Reinforced Structural Brace Ring

(Fig 9)

144

600

Discharge pipe
(by plumber)
Holding tanks must only be
pumped out half way

HOLE FOR DISCHARGE


(BY PLUMBER)

(Fig 10)

Septic Tank & Holding Tank Installation Guide

(Fig 11)

(Fig 13)

(Fig 14)

Septic Tank & Holding Tank Installation Guide

*6473,;065

3:,7;0*;(52

1. Secure the manhole cover then ll tank with water to outlet level.
2. After completely lling the tank with water, backll around the tank with clean ll and compact thoroughly. Thorough compaction is required to secure
anchors and to ensure the backll has the same density as the surrounding ground.
3. Compaction is important ensure there are no large or sharp objects in backll material.
4. Ensure surface water run-off is directed away from pipe trenches and tank installation.

Item no.

Qty

Description

Tank Base - factory predrilled to


nominal capacity of 3200L

Tank Lid

Manhole Cover

Inspection Cover

Optional

Bafe - Optional at extra cost.


Please refer your local authority
requirements

Accessory Kit Contents

3200L Septic Tank

3200L Septic Tank w/Riser

4000L Septic Tank

;,*/50*(3+,;(03::<44(9@
All Dimensions (mm), Capacities and Weights Nominal

3200L

3200L / Riser

4000L

Overall tank height

2038

2410

2410

Liquid depth level

1427

1427

1732

Tank rim to invert of outlet

200

585

385

Under roof to liquid level

460

845

540

Maximum cover to inlet pipe

300

685

380

Maximum cover to outlet pipe

350

735

430

Overall diameter

1998

1998

1998

Tank base to ground level

1887

2272

2272

Capacity

3200L

3200L

4000L

Weight

122kg

159kg

159kg

Weight including bafe

139kg

177kg

181kg

Ground Level

E F

C
Liquid Level

A
H
B

Septic Tank & Holding Tank Installation Guide

Inlet T-Junction

Outlet T-Junction

Manhole Self Tapping Screws,


10g 316 Stainless Steel

T-Junction Self Tapping Screws,


10g 316 Stainless Steel

10

Lid Bolt, Washer, Nut,


M6 316 Stainless Steel

11

Bafe Bolt, Washer, Nut,


M6 316 Stainless Steel

22

Anchor Rope

23

Installation Instructions

All Dimensions (mm), Capacities and Weights Nominal


A

Overall tank height

2038

Liquid depth level

1427

Tank rim to invert of outlet

200

Under roof to liquid level

460

Maximum cover to inlet pipe

300

Maximum cover to outlet pipe

350

Overall diameter

1998

Tank base to ground level

1887

Capacity

3200L

Weight

122kg

Weight including bafe

139kg

Ground Level

E F

C
Liquid Level

A
H
B

Septic Tank & Holding Tank Installation Guide

3/63+05.;(52

3:,7;0*;(52>0;/90:,9
Item no.

Qty

Description

Tank Base - factory predrilled to


nominal capacity of 3200L

Tank Lid

Manhole Cover

Inspection Cover

Accessory Kit Contents


5

Inlet T-Junction

Manhole Self Tapping Screws,


10g 316 Stainless Steel

T-Junction Self Tapping Screws,


10g 316 Stainless Steel

10

Lid Bolt, Washer, Nut,


M6 316 Stainless Steel

Item no.

Qty

Septic Tank Base factory predrilled


to nominal capacity of 3200L including
factory tted reinforcing ring (item 12)

Tank Lid

Manhole Cover

Optional

16

Riser Side Panels

18

Riser Side Panel Keyed

Accessory Kit Contents

11

Bafe Bolt, Washer, Nut,


M6 316 Stainless Steel

22

Anchor Rope

23

Installation Instructions

Outlet T-Junction

Manhole Self Tapping Screws


10g 316 Stainless Steel

T-Junction Self Tapping Screws


10g 316 Stainless Steel

10

Lid Bolt,Washer,Nut
M6 316 Stainless Steel

11

Bafe Bolt,Washer,Nut
M6 316 Stainless Steel

20

16

Riser/Tank Bolt, Washer, Nut


M8x50 316Stainless Steel

21

12

Riser Ring Bolt, Washer, Nut


M8x25 316 Stainless Steel

Overall tank height

2038

Liquid depth level

1427

Tank rim to invert of inlet

200

Under roof to liquid level

460

Maximum cover to inlet pipe

350

Overall diameter

1998

Tank base to ground level

1887

22

Anchor Rope

Capacity

3200L

23

Installation Instructions

Weight

122kg
Note:
Only one riser can be used
Riser may only be tted to tank with factory tted reinforced structural
brace ring

Ground Level
E

All Dimensions (mm), Capacities and Weights Nominal

D
C

Liquid Level

Overall tank height

2410

Liquid depth level

1427

Tank rim to invert of outlet

585

Under roof to liquid level

845

Maximum cover to inlet pipe

685

Maximum cover to outlet pipe

735

Overall diameter

1998

Tank base to ground level

2272

Capacity

3200L

Weight

159kg

Weight including bafe

177kg

A
Discharge pipe
(by plumber)

H
B

Septic Tank & Holding Tank Installation Guide

Inlet T-Junction

Note:
Bafe and Outlet T-Junction not required in a holding tank
Plumber to supply and install discharge pipe

Inspection Cover
Bafe Optional at extra cost.
Please refer to your local authority
requirements

Riser Ring Contents

All Dimensions (mm), Capacities and Weights Nominal

3200L Septic Tank

Description

Ground Level
E F
C

Liquid Level

A
H
B

3200L Holding Tank

Septic Tank & Holding Tank Installation Guide

3/63+05.;(52>0;/90:,9

3:,7;0*;(52
Item no.

Qty

Description

Item no.

Qty

Holding Tank Base factory predrilled


to nominal capacity of 3200L including
factory tted reinforcing ring (item 12)

Tank Lid

Septic Tank Base factory assembled


including factory tted reinforcing ring
(item 12) and tank base extensions
predrilled to nominal capacity of 4000L
(items 15,16,17, 20, 21)

Manhole Cover

Tank Lid

Inspection Cover

Manhole Cover

Inspection Cover

16

Riser Side Panel

7 + 13

Optional

18

Riser Side Panel - Keyed

Riser Ring Contents

Accessory Kit Contents


1

Inlet T-Junction

Manhole Self Tapping Screws


10g 316 Stainless Steel

10

Inlet T-Junction

Outlet T-Junction

T-Junction Self Tapping Screws


10g 316 Stainless Steel

Manhole Self Tapping Screws


10g 316 Stainless Steel

Lid Bolt,Washer,Nut
M6 316 Stainless Steel

T-Junction Self Tapping Screws


10g 316 Stainless Steel

20

16

Riser/Tank Bolt, Washer, Nut


M8x50 316 Stainless Steel

10

Lid Bolt,Washer,Nut
M6 316 Stainless Steel

21

12

Riser Ring Bolt, Washer, Nut


M8x25 316 Stainless Steel

11

Bafe Bolt,Washer,Nut
M6 316 Stainless Steel

22

Anchor Rope

14

Bafe Extension Bolt,Washer,Nut


M6 316 Stainless Steel

23

Installation Instructions

22

Anchor Rope

23

Installation Instructions

Overall tank height

2410

Liquid depth level

1427

Tank rim to invert of inlet

585

Under roof to liquid level

845

Maximum cover to inlet pipe

735

Overall diameter

1998

Tank base to ground level

2272

Capacity

3200L

Weight

159kg

Note:
4000L tank bases are supplied factory assembled
(other than Bafes and T-Junctions)
A riser must not be tted to 4000L tank

E
C

Liquid Level

A
H
B
Discharge pipe
(by plumber)

Septic Tank & Holding Tank Installation Guide

Dimensions Nominal (mm)

Ground Level

3200L Septic Tank w/ Riser

Bafe Optional at extra cost.


Please refer to your local authority
requirements

Accessory Kit Contents

Dimensions Nominal (mm)

Note:
Bafe and Outlet T-Junction not required in a holding tank
Only one riser can be used
Riser may only be tted to tank base with factory tted reinforced structural brace ring
Plumber to supply and install discharge pipe
Holding tanks must only be pumped out half way

Description

Overall tank height

2410

Liquid depth level

1732

Tank rim to invert of outlet

385

Under roof to liquid level

540

Maximum cover to inlet pipe

380

Maximum cover to outlet pipe

430

Overall diameter

1998

Tank base to ground level

2272

Capacity

4000L

Weight

159kg

Weight including bafe

181kg

Ground Level

E F

C
Liquid Level

A
H
B

3200L Holding Tank w/ Riser

Septic Tank & Holding Tank Installation Guide

10