NUM Corporation

Engineering Department

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

1/17

Windows 7 Professional and Home Premium 32 Bit Version

NUMTools Workshop (ver. P) Installation


Windows 7 generally supports 32- and 64-bit architectures (x86 and x64). For
NUMTools version P a 32-Bit OS is definitely required, because the Vista32X_Way
drivers will ONLY work with a 32-bit operating system.
The Vista32 X_Way drivers rev. 2.6 are not part of the NUM Tool Workshop
package. They could be obtained separately either from:
NUM FTP Download Scheneider drivers v2.6
or
Schneider Electric - Driver Pack V2.6
The Schneider communication drivers pack V2.6 have to be installed before the NUM
Tool Workshop is loaded. If the drivers are not loaded prior to attempting to load NUM
Tool Workshop then the following error is displayed:

Installing Unitelway and XIP Windows VISTA/7 Drivers


1. Run the _installdrivers.html file on the installation CD.
This will display the following screen:-

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

2/17

2. Select required driver to load (under Windows VISTA32) :-

a)

UNI-TELWAY Port Com


Setup V2.0 IE10
and/or
XIP X_WAY on TCP/IP Setup V2.0 IE10

b)

Note: Selecting either of the above will load in the Drivers Manager
before the driver.
3. On the message Pending Schneider Driver Manager for Vista32 Click

Install
4. Follow the on screen prompts
5. Drivers will install with no Finish notification! Restart PC

Installing NUM Tool Workshop (Ver. P00)


1. Insert CD into PC AutoPlay displays the below message.
Click on Run setup.exe
NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

2.

Date:12/23/10

NUM INFORMATION
US N 180

3/17

Do you want to allow the following program from an unknown


publisher to make changes to this computer?
Message posted - click Yes to continue Install shield runs.

3. NUM Tool welcome screen page: click Next to continue.


4. License Agreement screen page: click Yes to continue.
5. Information screen page:click Next to continue.
6. Choose Destination Location screen page: click Next if Location is OK or
browse to desired location.

7. Selection of Software installation package screen page: Leave Install NUM


Tool and HMI selected - click Next to continue
NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

NUM INFORMATION
US N 180

Date:12/23/10

4/17

8. Selection of the Human Machine Interface screen page: click Next to


continue.
(PC Panel MMI and PC Standard MMI (Apex screens) can be selected if required)
9. Setup Type screen page: Leave Complete selected then click Next to
continue.
10. Licence message page: click OK to continue

11. User Licence PLCTool and SETTool page: lease enter User Name /
Company Name / User Licence click Next to continue.

12. Select Program Folder screen page: click Next for default location
(Location can be changed if necessary).
13. Select communication and driver installation screen page: Please select
the desired communication (Com serial link is default). Then click Next to
continue.

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

5/17

14. Select language screen page: select Desired Language click Next to
continue.
15. Information of installation screen page: click Next to continue.
16. Setup Status screen page: leave as software is configured.
17. DllRegisterServer in C:\Program Files\CommonFiles\microsoft
shared\DAO\dao350.dll succeeded.
When message is displayed just click click OK to continue
18.

SYSTEM UPGRADE
Machine Manager required Borland Database Engine
Would you like to install Borland components?
When message is displayed just click Yes to continue

19. Registry Editor message page: click Yes to continue.


20. Second Registry Editor message page: click OK to continue
21. Install Shield Wizard Complete screen page: click Finish to continue
22. Remove installation CD and reboot PC.

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

NUM INFORMATION
US N 180

Date:12/23/10

6/17

XIP-Driver Setup
Setup the CNC Parameters with PC Standard MMI (Apex).
The XIP driver uses the following NC parameters:
P100 N1 - XIP Xway address =
3F (Hex)
P124 CNC TCP/IP Address =
192.168.0.254
P125 CNC Subnet Mask
=
255.255.255.0
P100 N1 corresponds to the Station Address in Step 3 below. Range is 0 to 3F Hex (0
to 63 decimal)
Setting of the PC Network Adaptor:
IP address
= 192.168.0.150
Subnet Mask
= 255.255.255.0
Remark: The above values for parameters and Network settings are example values only.

1. Power up CNC Connect PC to CNC TCP/IP adaptor with a Cross (X) network cable.
2. Set-up the Network Adaptor Settings
(Control Panel > Network and Internet > Network and Sharing Centre > Change Adaptor
Settings)
In the below example IP Version 4 is modified.

At this point it is possible to ping the CNC from the PC i.e. ping 192.168.0.254 and
check response.

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

NUM INFORMATION
US N 180

Date:12/23/10

7/17

3. Open Communication & Language parameter program


(Start -> All Programs -> NUM Tool Win Vista32 -> Communication -> Communication &
Language parameter).

Ensure Station under NUM Tool and


NUMpass CNC configuration, if NumPass is
loaded, is set to CNC P100 N1 value. 3F
(hex) in this example
(CNC Parameter 100 value - Range is 0 to 3F
This equal 0 to 63 decimal)

4. Ensure XIP is selected in Type of Communication box.


5. Enter Station Value in NUM Tool Box and NUMpass CNC configuration Box (if
Numpass is loaded).
This value equals CNC parameter P100 N1 . (Set to 3F Hex in this example)
6. Click Validate - Communication is now set to XIP01 is displayed in the LOADING
window.
(on subsequent running of the program the loading window will several references to XIP01)

7. Click Configuration This will display Schneider Drivers Management Properties :Select XIP Driver Tab.

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

NUM INFORMATION
US N 180

Date:12/23/10

8/17

8. Click Configuration (Answer Yes to any questions allowing program to make


changes)
IF no XIP has been previously been set-up on the PC then the following warning will be
displayed :

Click OK to continue
This will then display New XIP profile creation

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

NUM INFORMATION
US N 180

Date:12/23/10

9/17

Under TCP/IP Network Adaptor drop down box select the required Adaptor and click
OK
(Note TCP/IP Address of PC as set in Step 2. in this example 192.168.0.150)

This displays the following:

9. Click Bind (not necessary if already performed above).


Under TCP/IP Network Adaptor Drop down box select the required Adaptor and
click OK
(Note TCP/IP Address of PC as set in Step 2. in this example 192.168.0.150)

10. Enter New Remote Host data as shown below


E.g. Station = CNC / XWAY address = 0 . 63 / IP Address = 192.168.0.254
XWAY address = 0 . 63 - P100 N1 = 3F
Deselect Enable automatic detection.
Ensure DNS is not selected
Enter Local host XWAY Address = 0.63
Note Local Host and New remote host XWAY addresses must have a different
value.
11. Click Add button
NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

10/17

12. Click Save Message The new configuration has been saved successfully click OK

13. Under XIP menu bar Select Reset This Resets the XIP driver.
(or Stop then Start)
14. Under Test menu select ICMP Ping > Select Ping

15. Close all windows and reboot PC and CNC Important to do this.

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

11/17

Testing XIP Communication


1. Open Communication & Language parameter program
2. Select Configuration > Select XWAY Test Tab
3. Under Driver box - Name: Drop down menu - Select XIP
4. Change Remote address: to 0.63.0
5. Select Connect
State in request box becomes Connected icon is active.
(there may be a slight delay)

6. Select Start - The request will flash red / yellow and the number will increment.

Com Port Set-up with Unitelway Driver


1. Run Communication & Language parameter program
(Start -> All Programs -> NUM Tool Win Vista32 -> Communication ->
Communication & Language parameter).

2. Ensure COM is selected in Type of Communication box.


3. Click Validate
(There will be several references to COM in the Loading window)

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

12/17

4. Click Configuration This will display Schneider Drivers Management


Properties :

5. Select UNITELWAY Driver Tab


6. Select Configuration. (Answer Yes to any questions allowing program to
make changes)
COM1 is the default Com port.
An additional Com port may be shown if
using a USB - RS232 device in this
case ensure Force Virtual Com Port
(shown below) is selected.

7. Select Edit to display Station Parameters - the 3 tabs are displayed :Set values as below.

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

13/17

The Baud rate can be set from 300 to 115200bps.


Ensure Unitelway and NumPLC are selected
8. Click OK to close Station Parameters.
9. Click Apply to Reset Unitelway Driver. Drivers Reset is OK is displayed
10. Click OK to exit Unitelway Configuration
11. Click OK to exit Schneider Drivers Management
Testing Unitelway Communication
1. Connect Comms cable from NC to PC. (Port 0 in this case)
2. Configure Comms Port on control P112 N0 = 00 / N1 = 55 / N2 = 01
Port 0 / 115200 baud rate
3. Click Configuration This will display Schneider Drivers Management
Properties.
4. Select X_WAY Test tab.
5. Select Connect State in request box becomes Connected icon is active.
(there may be a slight delay while the correct baud rate is selected)
6. Select Start - The request will flash red / yellow and the number will increment.

7. Select Stop Select Disconnect. State to Disconnected.


8. Select OK to close Drivers Manager.
9. Select Exit to close Communication & Language parameters

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

14/17

HSL PCI Set-up Windows 7


The document details HSL PCI setup Driver installation - with Windows 7 (32 Bit)
The HSL PCI C101 board is manufactured by MOXA and has a Num part number of
0202206297.
Download the Drivers from the MOXA website C101.EXE (self extracting zip File)
1. With PC Power off cable disconnected fit the HSL PCI card to the PC.
(Use a wrist strap antistatic).
2. Power-up PC.
3. Select the C101.EXE - Right Click Select Troubleshoot compatibility.
The C101.exe file is run in compatibility mode to ensure it loads the drivers in the
c:\windows\System32 folder.

4. Select Try recommended Settings

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

15/17

5. Test compatibility settings for the program is displayed Select Start program
button

6. When this message appears: Do you want to allow the following program from an
unknown publisher to make changes to this computer - Press YES button.
7. A DOS window appears a question displayed Continue Extraction?
Press Y followed by enter key.

This extracts the necessary files to the C:\Windows\System32 directory (folder).


Dos window closes.
8. The Test compatibility settings for the program screen is displayed Select Cancel
button.
9. Go to Device Manager
10. Right Click PCI serial port
(Warning symbol on icon showing a driver problem)

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

16/17

11. Select Update driver software.


12. Click Browse my computer for driver software.

13. Browse to C:\Windows\System32 folder - Click Next

Searching message is displayed.

NUM Corporation
603 East Diehl Road, Suite 115
Naperville, IL 60563-1477 USA Web:

Phone: 630-505-7722
Fax:
630-505-7754
www.num.com

Axium Power
Software under OS
Windows 7

Date:12/23/10

NUM INFORMATION
US N 180

17/17

14. Windows Security image acknowledge:

15. Click Install this driver software anyway.


16. Message Installing Driver software is displayed.
17. Message Windows has successfully updated your driver software

18. Click close


19. Restart PC