Performance
Extensive fatigue testing has been completed and incorporated into third party fatigue modeling such as Cerberus and Flexor,
as well as proprietary service company models.
Fatigue testing results for 2.000 outer diameter (O.D.) QT-1300: The average number of
fatigue cycles to failure is plotted against wall thickness and internal pressure.
Head-to-head fatigue testing of QT-1300 vs QT-1000. Note that QT-1300 has a higher average
fatigue life than QT-1000 at all pressures.
Product Details
Available Strings
TRUE-TAPER
Straight wall
Straight wall Flash-Free
String with an electric wireline or capillary tube installed
Available Strings
Wall Thickness:
44.5 mm - 88.9 mm
0.134 - 0.250
3.4 mm - 6.4 mm
Product Details
Chemistry
QT-1300 is made of high strength low alloy (HSLA)
steel similar in composition to other QT grades with
increased amounts of solid solution elements and of
micro-alloy strengthening elements.
Compatibility
To ensure functionality, QT-1300 has been tested for
compatibility with typical coiled tubing equipment
such as injectors, connectors for downhole tools, and
blow out preventers (BOP shear and slip testing).
w w w. n ov. co m /q u a l i t y t u b i n g
q u a l i t y t u b i n g @ n o v. c o m
Success
QT-1300 has been successfully utilized by development partners both onshore and offshore in high pressure, high
temperature (HPHT) wells and for extended reach applications - offshore, in the Gulf of Mexico and North Sea, and
onshore, in the Bakken, Marcellus and US shales.
The longest string of QT-1300 manufactured to date is over 35,000 continuous feet in length.
In the North Sea, we partnered with a customer to provide a coiled tubing solution to deploy, activate and
retrieve perforating guns after firing them downhole.
Previous Practice:
Additional 1,500 feet of wellbore is drilled in preparation
for the perforating sequence. Guns are lowered via
tubing and fired. Previous grades of tubing were
not strong enough to pull the guns out so they were
released.
The Solution:
QT-1300 provides the additional axial load capacity to
retrieve the guns after firing, eliminating the need for
additional wellbore, saving time and expenses.
w w w. n ov. co m /q u a l i t y t u b i n g
q u a l i t y t u b i n g @ n o v. c o m
Downhole Solutions
Drilling Solutions
Industrial Solutions
Corporate Headquarters
7909 Parkwood Circle Drive
Houston, Texas 77036
United States
Phone: 713 375 3700
Fax: 713 346 7687
Production Solutions
www.nov.com/QualityTubingLocations
Tubular and Corrosion Control Solutions
National Oilwell Varco has produced this brochure for general information only, and it is not intended
for design purposes. Although every effort has been made to maintain the accuracy and reliability of its
contents, National Oilwell Varco in no way assumes responsibility for liability for any loss, damage or injury
resulting from the use of information and data herein. All applications for the material described are at the
users risk and are the users responsibility.
w w w. n o v. co m / q u a l i t y t u b i n g
2013 National Oilwell Varco
All rights reserved
D932000055-MKT-001 Rev. 01