Over 300 customers in 50 countries

UNILAB UNISUITE COAX


UNILAB UNISUITE is the smart platform and unique tool for design and rating of shell & tube, plate, tube in tube and coaxial heat exchangers.
All software use the library REFPROP of NIST (National Institute of Standards and Technology). It also comprises the
thermodynamic and thermophysical properties of more than 300 liquids & gases, and 12 mixtures of liquids, many of
them commonly used in the Chemical & Petrochemical fields. Each software integrates correction factors, which lets
the user to align results with the experimental data. Our calculation models are supported by almost 30 years of research & expertise. Our products represent a consolidated value for the HVAC industry, and they can be used in the
Power Generation, Food & Pharmaceutical industries.
UNILAB UNISUITE COAX allows you to verify and design coaxial
heat exchangers of the following types: fluid-fluid, evaporation,
condensation, vapor inside/outside the tubes. A powerful program that guides the designer to the realization of high-efficiency
heat exchangers as quick as possible. It allows you to design a
heat exchanger from scratch without setting any dimensional
parameters. Specifying only the fluids temperature/flow rates,
the required capacity and the maximum pressure drops, it will
automatically calculate one or more high-efficient heat exchangers that achieve the required capacity with a minimum pressure
drop. After that, you can review the results, select one of the
many combinations generated and send the documents made
directly to the production department, including the 3D design of
the heat exchanger in 1:1 scale, exportable in many CAD formats.

FUNCTIONALITIES
Available no. 7 calculation modalities:
- Fluid-fluid
- Condensation inside tubes
Calculation
- Condensation outside tubes
modalities
- Evaporating inside tubes
- Evaporating outside tubes
- Steam inside tubes
- Steam outside tubes
Available no. 3 calculations typologies:
Calculation
- Free calculation: you have to specify all the exchangers dimensional parameters from scratch
typologies
- Verify heat exchanger: you just verify an exchanger from the archive
- Heat exchangers selection: it selects an exchanger suitable with the customer requirements
In Free Calculation, the user can choose:
- Verify: the user can rate the capacity and the pressure drops, knowing all the geometrical parameters of the
exchanger and work conditions, changing one or more input data at the same time (for example: fluid flow,
fluid, tube type, fluid temperatures, etc)
- Design: it is possible to insert the work conditions and the capacity required, without knowing all the
geometrical parameters, to build the best exchanger for the required capacity
Calculation
- Design from scratch: allows the complete design of a brand new exchanger from scracth. In case you need
modes
to design a special exchanger and you lack the time to use a complex software, and set all the parameters,
with our software you just have to select the fluids, set the working conditions and the required capacity, click
on the Automatic calculation box and you are done. With this new feature you can just type the required
capacity and click a button, and then the software will design a brand new exchanger without any dimensional parameter set in. This lets you design a special exchanger, that perfectly matches the requirements of the
customer, in just no time
Possibility to set, edit and erase the customers data, geometries, connections, exchangers, materials, fluids
Archive
and drawings
Management
Possibility to save an exchanger already rated in database and create new series
The user is able to manage the geometrys data (tubes) with the possibility to add new ones
Geometries
Complete management of geometrical features: tubes (smooth, grooved, radial finned)
Added Wolverine and Wieland tubes (some models)
The user is able to manage the materials data with the possibility to add new ones, specifying and inserting
Materials
the following information: Thermal Conductivity (W/m*K) and the Density (kg/m3)
Possibility to use the archive or add new ones
Fluids
The user has the possibility to test the fluids, with charts and/or tables
Available no. 2 printout templates:
- Brief printout (technical data)
Printouts
- TEMA printout (in according with the TEMA norms)
Possibility to export printouts in the formats PDF, Excel, Word
Possibility to design the plan of the plate automatically with the maximum number of tubes possible in the
plate
Possibility to delete manually some tubes and modify some information directly on the drawing (like the tube
Plate drawings
disposition and the plate configuration) so the drawing will update automatically
Possibility to save the modified data from the drawing to the calculation
Drawings can be exported into AutoCad (DWG, EMF)
CAD 3D
Complete automized drawing of the heat exchanger
Unit of
Possibility to choose or modify the system: SI, Imperial, Custom, Technical
measurement
Correction
These correction factors align the softwares results (with approximation margin) with experimental data
factors
Projects
Calculations can be saved in files of small dimensions and it is possible to restore them
archive
English, Italian, German, French, Spanish, Russian and Chinese
Languages
Other languages on request with additional cost
Unicode support for non Latin alphabets
Logo
Logo and company data linked to the main brand of the company
Technical
Only to customers with regular subscription of maintenance contract, which covers a maximum of n 3 techsupport
nical Licenses. Automatic renewal
Activation
Digital download An internet connection is required for both installation and activation. Further accesses to
modality
the internet connection may be required while using the software
System
Operating System Microsoft Windows Vista, 7 and 8 32 or 64 bits
requirements
Book a demonstration online at:

bit.ly/unilabdemo

Watch videos at:

bit.ly/unilabyoutube

Follow us on:

bit.ly/unilablinkdin

Unilab Srl - Via Nino Bixio, 6 35131 Padova, Italy